  1. Apr 7, 2026 Routine · 2 non-critical
    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. [Describe].

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY INSTALLLED

      There is a leak coming from the pH probes on the automatic monitoring panel.

      Correction: Repair the leak and maintain equipment in good repair.

      Code ATCP 76.33(1)(e)2. - INSTALLATION OF POOL EQPT.

  2. Apr 30, 2025 Follow Up · No items found

    No violations cited.

  3. Apr 28, 2025 Routine · 1 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical

      PH

      The pH is 8.3. The whirlpool must remain closed until it is lowered.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  4. Apr 17, 2024 Routine · 2 critical, 1 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

    • Serious Critical

      CO ALARM-POOL AREA

      There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.

      Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA

  5. Jun 9, 2023 Follow Up · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE

      The combined chlorine is 1.38.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Non-critical Repeat

      MONTHLY OPERATION REPORTS NOT SUBMITTED

      Monthly operation reports are not being kept in accordance with ATCP 76.32(1).

      Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).

      Code [A] ATCP 76.32(1)

  6. May 19, 2023 Routine · 4 non-critical, 2 repeat
    • Not serious Non-critical

      COMBINED CHLORINE

      The combined chlorine is 1.38.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

    • Not serious Non-critical Repeat

      TELEPHONE NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code [A] ATCP 76.26(2)

    • Not serious Non-critical Repeat

      MONTHLY OPERATION REPORTS NOT SUBMITTED

      Monthly operation reports are not being kept in accordance with ATCP 76.32(1).

      Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).

      Code [A] ATCP 76.32(1)

    • Not serious Non-critical Corrected on site

      WATER LEVEL TOO LOW

      The pool water level is too high and is not adequate for continuous effective surface skimming. The water level was adjusted during inspection.

      Correction: Raise the water level until the skimming of the water surface is adequate.

      Code [B] ATCP 76.11(2)(a)