RecordWell Data

Excel Inn

1033 SE FRONTAGE RD, Mount Pleasant, WI 53177 · Racine County

26cited violations
2serious tier
8inspections

Establishment

Type
Lodging (Hotel and Motel - 5 - 30 Rooms)
Inspected by
Central Racine County Health Department
License / ID
CDYA-C8MNZH
Status
Permitted
Phone
(262) 886-3830
Official record
Central Racine County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026292
2025100
2024280
2023390

Inspections

  1. Feb 27, 2026 Admin Follow Up · 4 non-critical, 4 repeat
    • Serious Critical Repeat

      Smoke alarms provided

      Room does not have an operational smoke alarm.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule. Room cannot be rented until smoke alarm is operational.

      Code ATCP 72.18(11)(a)

    • Not serious Non-critical Repeat

      Sleeping rooms maintained in good repair

      The screen of the room has a hole.

      Correction: Maintain all sleeping rooms in good repair.

      Code ATCP 72.19(1)(a)2.

    • Not serious Non-critical Repeat

      Ice bucket with liner sanitization

      An ice bucket is not provided with a single-use disposable liner and is not wash, rinsed, and sanitized in an approved manner.

      Correction: Provide a single-use disposable liner or wash, rinse, and sanitize the ice bucket in an approved manner.

      Code ATCP 72.20(6)(f)

    • Not serious Non-critical Repeat

      Nonabsorbent mattress cover or mattress surface

      The mattress in guest rooms is not provided with a nonabsorbent mattress protector that covers the entire sleeping surface.

      Correction: Provide a nonabsorbent mattress protector that covers the entire sleeping surface or have an easily cleanable nonabsorbent mattress surface.

      Code ATCP 72.20(8)(d)

  2. Feb 25, 2026 Routine · 5 non-critical
    • Serious Critical

      Smoke alarms provided

      Room does not have an operational smoke alarm.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule. Room cannot be rented until smoke alarm is operational.

      Code ATCP 72.18(11)(a)

    • Not serious Priority Foundation Corrected on site

      Vomit and diarrheal clean-up - written procedures available

      The operator does not have procedures in place for responding to vomiting and diarrheal events. Procedure was provided in email.

      Correction: Provide procedures that include clean-up methods and actions employees must take to minimize the spread of contamination and the exposure of employees, consumers, food, and surfaces to vomitus or fecal matter.

      Code ATCP 72.22(4)

    • Not serious Non-critical

      Sleeping rooms maintained in good repair

      The screen of the room has a hole.

      Correction: Maintain all sleeping rooms in good repair.

      Code ATCP 72.19(1)(a)2.

    • Not serious Non-critical

      Ice bucket with liner sanitization

      An ice bucket is not provided with a single-use disposable liner and is not wash, rinsed, and sanitized in an approved manner.

      Correction: Provide a single-use disposable liner or wash, rinse, and sanitize the ice bucket in an approved manner.

      Code ATCP 72.20(6)(f)

    • Not serious Non-critical

      Nonabsorbent mattress cover or mattress surface

      The mattress in guest rooms is not provided with a nonabsorbent mattress protector that covers the entire sleeping surface.

      Correction: Provide a nonabsorbent mattress protector that covers the entire sleeping surface or have an easily cleanable nonabsorbent mattress surface.

      Code ATCP 72.20(8)(d)

  3. May 8, 2025 Follow Up · No items found

    No violations cited.

  4. Dec 3, 2024 Follow Up · No items found

    No violations cited.

  5. Nov 20, 2024 Routine · 8 non-critical, 1 repeat
    • Not serious Non-critical Corrected on site

      TOILET FACILITIES - SOAP AND TOWELS

      There was no soap provided in the toilet room for room #18.

      Correction: Provide soap, single-service towels, or other approved means of drying hands in each toilet room.

      Code ATCP 72.10 (6) (d)

    • Not serious Non-critical Corrected on site

      SMOKE DETECTORS - REQUIREMENT

      Smoke detectors are not in working order in rm 35

      Correction: batteries replaced during inspection

      Code ATCP 72.14 (2) (c)

    • Not serious Non-critical

      WINDOW SCREENING

      Window screen has a large hole in room 17.

      Correction: Provide screening on all windows that can be opened to the outside.

      Code ATCP 72.14 (2) (e)

    • Not serious Non-critical Repeat

      PLUMBING CROSS-CONNECTIONS

      The ice machine located in the public access laundry room does not have a proper air gap installed on the drain. The drain feeds into a bucket with a pump and the pump feeds into a sewer pipe that not directly connected.

      Correction: Install an 2" air gap on the line from pump into the sewer line. Take photo and send to health dept by correct by date.

      Code [A] ATCP 72.10 (4)

    • Not serious Non-critical

      CARBON MONOXIDE DETECTORS - IMPROPERLY LOCATED

      Carbon monoxide detector is improperly located on the walls of the fuel burning appliance.

      Correction: Carbon monoxide detectors are required to be installed on the ceiling of the room with the FBA. Move all CO detectors to the ceiling. Moving forward each sleeping room will not require a CO detector

      Code [B] ATCP 72.145 (3)

    • Not serious Non-critical

      PLUMBING FIXTURES – SANITARY CONDITION

      The bathtubs in room 11 and 18 have cracks

      Correction: Repair the surface of the basin or replace bath tub in rooms 11 and 18.

      Code [C] ATCP 72.10 (4)

    • Not serious Non-critical

      PREMISE – EXTERIOR BUILDING

      The exterior window outside of room #23 is boarded up.

      Correction: Repair and maintain the exterior of all buildings.

      Code [D] ATCP 72.15 (4)

    • Not serious Non-critical

      MATTRESS PAD PROVIDED/SUFFICIENT SIZE

      Mattress pad does not completely cover mattress in room #35.

      Correction: Provide a mattress pad that completely covers the mattress.

      Code [H] ATCP 72.11 (5)

  6. Nov 16, 2023 Routine · 6 non-critical, 1 repeat
    • Not serious Non-critical

      WINDOW SCREENING

      Window screen were observed to be torn in the following rooms 16, 19 and 38.

      Correction: Repair or replace the screening on all windows that can be opened to the outside.

      Code ATCP 72.14 (2) (e)

    • Not serious Non-critical

      INSECT AND RODENT CONTROL

      Cockroach observed in room 11 during inspection.

      Correction: Contact a pest control company to evaluate and eliminate the presence and harborage of insects and rodents in room 11. It is recommended to have other rooms evaluated for further infestation of cockroaches. Provide documentation from pest control company showing treatments used to evaluate and eliminate infestation of cockroaches.

      Code ATCP 72.15 (3)

    • Not serious Non-critical

      INSECT AND RODENT CONTROL

      There was evidence of mouse infestation in all rooms inspected and in the public access laundry room.

      Correction: Contact a pest control company to evaluate and eliminate the presence and harborage of insects and rodents. Provide invoice of pest control company showing treatment used to evaluate and eliminate infestation.

      Code ATCP 72.15 (3)

    • Not serious Non-critical

      PLUMBING CROSS-CONNECTIONS

      The ice machine located in the public access laundry room does not have a proper air gap installed on the drain.

      Correction: Provide an air gap or other approved backflow/backsiphonage protection device.

      Code [A] ATCP 72.10 (4)

    • Not serious Non-critical

      CARBON MONOXIDE DETECTORS - REQUIREMENT

      Estalishment has forced air furnaces that serve a series of units. It is unclear if there is a carbon monoxide detector in all of the required units.

      Correction: Provide a schematic showing the duct pattern from each of the forced air furnaces that supply heat to all areas of the motel. Indicate what units are served by each furnace and what units have a carbon monoxide detector installed within.

      Code [A] ATCP 72.145 (3)

    • Not serious Non-critical

      GENERAL MAINTENANCE

      The bath tub in room 11 has cracks in the basin.

      Correction: Repair or replace the tub basin in room 11.

      Code [C] ATCP 72.15 (1)

    • Not serious Non-critical Repeat

      PREMISE – PARKING AREAS

      The southern area of the parking lot has large pot holes and holding water.

      Correction: Maintain or repair parking areas so they are properly graded, drained and treated to minimize dust and dirt.

      Code [C] ATCP 72.15 (4)

  7. Aug 1, 2023 Follow Up · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      INSECT AND RODENT CONTROL

      Two cockroaches observed in a sticky trap in Room #20.

      Correction: Contact a pest control company to evaluate and eliminate the presence and harborage of insects and rodents.

      Code ATCP 72.15 (3)

  8. Jul 27, 2023 Follow Up · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      INSECT AND RODENT CONTROL

      Two cockroaches observed in a sticky trap in Room #20.

      Correction: Contact a pest control company to evaluate and eliminate the presence and harborage of insects and rodents.

      Code ATCP 72.15 (3)

Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.