Days Inn
13340 HOSPITALITY CT, Sturtevant, WI 53177 · Racine County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Central Racine County Health Department
- License / ID
- WKRR-BHEP5N
- Status
- Permitted
- Phone
- (262) 412-8065
- Official record
- Central Racine County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 2 | 8 | 5 |
| 2025 | 2 | 11 | 3 |
| 2024 | 1 | 7 | 1 |
Inspections
-
Jan 21, 2026 Follow Up · 3 critical, 3 non-critical
-
Not serious
Non-critical
Corrected on site
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is 20/100. Adjustment was made during inspection.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. Observed to be not working during inspection.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Corrected on site
TEST KIT APPROVED
An expired test kit was observed at intial inspection. New test kit is available at current inspection.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Serious
Critical
INTERLOCK CHALLENGE TEST
Once monthly challenge testing of the chemical feeder system has not been conducted to assess the interlock. Log is also not being kept.
Correction: Challenge test the chemical feeder system monthly to assess the interlock.
Code ATCP 76.13 (1)(c)3. - INTERLOCK MONTHLY TEST
-
Serious
Critical
Corrected on site
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is .36 for chlorine. A second test was ran after the operator added chlorine. Free chlorine was at 2.74.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The chemistry was ran twice due to the free chlorine being low. First test the pH was at 7.8. When adjustments were made, pH was at 8.1 for second test.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Corrected on site
-
Jan 9, 2026 Routine · 2 critical
-
Serious
Critical
Corrected on site
RECIRCULATION SYSTEM CONTINUOUS OPERATION
The pool recirculation system is not operational or not continuously operated. The recirculation system was off. The circulation system was turned on during inspection.
Correction: The pool must be closed immediately until the recirculation system is in place and in continuous operation.
Code ATCP 76.11(1) - RECIRCULATION SYSTEM PRESENT, CONTINUOUSLY O
-
Serious
Critical
CLOSING CRITERIA-FAILURE TO MEET 76.16
The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. Main drain is not visible.
Correction: Close the pool in the event of failure to comply with the water quality requirements pursuant to s. ATCP 76.16. Pool can open when pictures of sent to Lindsey verifying clairty.
Code ATCP 76.30 (1)(b) - FAILURE TO MEET ATCP 76.16
-
Serious
Critical
Corrected on site
-
Jan 15, 2025 Follow Up · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin has multiple pits where the paint has peeled. There is an accumulation of peeling paint on the bottom of the pool.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
Repeat
-
Jan 8, 2025 Routine · 3 critical, 7 non-critical, 1 repeat
-
Not serious
Non-critical
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is backward. The valve was fully open on the main drain and partially closed on the skimmer.
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Weir door is missing from the skimmer.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 40ppm.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower. This is an indoor pool and cyanuric acid is not needed. Discontinue use of the DiChlor or any other products that contain cyanuric acid.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
TEST KIT APPROVED
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
The water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Provided education during inspection.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin has multiple pits where the paint has peeled. There is an accumulation of peeling paint on the bottom of the pool.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Serious
Critical
AUTOMATIC AND CONTINUOUS DISINFECTION
Pool not automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment. The mother board for the automatic feeding system was removed to be repaired and pool was being fed chemicals by hand.
Correction: Pool must be immediately closed until chemical feeding equipment can be repaired or replaced and inspected. Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13. Nofity dept once feeder is repaired and operational.
Code ATCP 76.14 (1) - AUTOMATIC DISINFECTION
-
Serious
Critical
PH
The pH is 8.1.
Correction: Closed the pool until pH is within the specifications (7.2 to 7.8). Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Corrected on site
RESPONSIBLE SUPERVISOR SANITATION AND TESTING
Individual assigned to test the pool was using a test method that only read to 0.5ppm.
Correction: Provided education and onsite review to show responsible individual on how to use the Taylor Test Kit to read to the required specificity of 0.2ppm.
Code ATCP 76.21 (1)(c)4. - SANITAITON AND TESTING
-
Not serious
Non-critical
-
Jan 25, 2024 Routine · 1 critical, 6 non-critical
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for a muriac acid, sodium hypochlorite, sodium bicarb, sodium bisulfate, and phos free.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
No Combined chlorine plan present on site.
Correction: Develop a combined chlorine plan for pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents were found expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator was not aware of the interlock testing requirements. Provided education during inspection.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY
A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:
Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.
Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.