Green Ridge Condos
1412 WINDSOR WAY, Mt Pleasant, WI 53406 · Racine County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Central Racine County Health Department
- License / ID
- HSAT-7QX873
- Status
- Permitted
- Phone
- (262) 886-9653
- Official record
- Central Racine County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 2 | 10 | 6 |
| 2024 | 1 | 3 | 2 |
Inspections
-
Feb 13, 2026 Routine · 1 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
There are missing wiers on some of the skimmer baskets
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
The Main Drain Covers (Aegis 3030AEC) are expired as of 10/29/2024. Current cover is in good shape.
Correction: Replace the maindrain cover with the make and model number listed above. Send copy of receipt and signed affitdavit.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
-
Feb 26, 2025 Follow Up · 2 critical, 2 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The turnover rate is 6.54 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of less than 6 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained.The fittings on both of the pool filters have a leak leading to excess water on the pump room floor and pool deck.
Correction: Maintain the pool equipment. Repair or replace the fittings to prevent the leak.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
Repeat
RESPONSIBLE SUPERVISOR RECORDS MAINTAIN
Responsible supervisor is not ensuring that records are maintained. Monthly pool testing is not being submitted to the health department.
Correction: Have the responsible supervisor ensure that records are maintained. Submit monthly pool testing by the 10th day of the foolowing month.
Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE
-
Serious
Critical
Repeat
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The VGBA main drain covers are expired as of 10/29/2024; the covers are intact and installed correctly.
Correction: Correct the hazardous condition. Replace the VGBA main drain covers by the time of the next routine inspection.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Repeat
-
Feb 25, 2025 Routine · 4 critical, 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The turnover rate is 6.54 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of less than 6 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained.The fittings on both of the pool filters have a leak leading to excess water on the pump room floor and pool deck.
Correction: Maintain the pool equipment. Repair or replace the fittings to prevent the leak.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
PH
The pH is 8.2. The pool is closed until the pH measures at 7.2 to 7.8.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
MAXIMUM BROMINE
The maximum total bromine exceeds 10 ppm. The total bromine was 15.8 ppm. The pool is closed until the bromine is lowered to between 3-10 ppm.
Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.
Code ATCP 76.14(5)(g) -MAXIMUM BROMINE
-
Serious
Critical
Repeat
RESPONSIBLE SUPERVISOR RECORDS MAINTAIN
Responsible supervisor is not ensuring that records are maintained. Monthly pool testing is not being submitted to the health department.
Correction: Have the responsible supervisor ensure that records are maintained. Submit monthly pool testing by the 10th day of the foolowing month.
Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE
-
Serious
Critical
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The VGBA main drain covers are expired as of 10/29/2024; the covers are intact and installed correctly.
Correction: Correct the hazardous condition. Replace the VGBA main drain covers by the time of the next routine inspection.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Repeat
-
Feb 28, 2024 Routine · 2 critical, 1 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The turnover rate is 7.26 hours..
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [6 hours].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Serious
Critical
RESPONSIBLE SUPERVISOR RECORDS MAINTAIN
Responsible supervisor is not ensuring that records are maintained. Monthly testing reports are not being submitted by the 10th day of the following month.
Correction: Have the responsible supervisor ensure that records are maintained and submitted to the health department.
Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.