Windpoint Apartments

4042 N MAIN ST A3, Racine, WI 53402 · Racine County

36cited violations
7serious tier
5inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Central Racine County Health Department
License / ID
HSAT-7QXR5F
Status
Permitted
Phone
(833) 681-0935 ext. Janet Neu
Official record
Central Racine County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262186
2025150
2024191
2023140

Inspections

  1. Jun 16, 2026 Follow Up · 2 critical, 6 non-critical, 8 repeat
    • Not serious Non-critical Repeat

      SAFETY DATA SHEET

      A safety data sheet was not available for the Taylor test kit reagents.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Expired 5/2026.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical Repeat

      FIRST AID KIT-ADHESIVE TAPE

      The first aid kit is missing adhesive tape.

      Correction: Provide adhesive tape for the first aid kit.

      Code ATCP 76.27(1)(b)4. - ADHESIVE TAPE

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Serious Critical Repeat

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      The chlorine barrels are not separated from the acid barrels.

      Correction: Store oxidizers (chlorine) separately from acids.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical Repeat

      CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE

      The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.

      Correction: Close the pool in the event of a nonfunctional emergency phone.

      Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE

  2. Jun 15, 2026 Routine · 4 critical, 6 non-critical
    • Not serious Non-critical

      SAFETY DATA SHEET

      A safety data sheet was not available for the Taylor test kit reagents.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. Expired 5/2026.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      FIRST AID KIT-ADHESIVE TAPE

      The first aid kit is missing adhesive tape.

      Correction: Provide adhesive tape for the first aid kit.

      Code ATCP 76.27(1)(b)4. - ADHESIVE TAPE

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Serious Critical

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      The chlorine barrels are not separated from the acid barrels.

      Correction: Store oxidizers (chlorine) separately from acids.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      The chlorine level was tested twice. Initial test was at 0.21 ppm and a second test after the feeder was adjusted. The second test was at 0.58 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. The pool was closed during the inspection.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      TELEPHONE ACCESSIBLE

      The emergency telephone is not working. Close pool until phone is repaired and the chlorine level reaches a minimum of 1.0 ppm.

      Correction: Provide a working telephone or other technology capable of connecting with emergency services.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE

    • Serious Critical

      CLOSING CRITERIA-NO FUNCTIONAL EMERGENCY PHONE

      The Responsible Supervisor or operator has not closed the pool due to a nonfunctional emergency phone.

      Correction: Close the pool in the event of a nonfunctional emergency phone.

      Code ATCP 76.30 (1)(g) - FUNCTIONAL EMERGENCY PHONE

  3. Jun 6, 2025 Routine · 5 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      SAFETY DATA SHEET

      Safety data sheets were not available for the chemicals in the test kit.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 53 ppm with a saturation index of -0.8.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises:

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

  4. Jun 21, 2024 Routine · 1 critical, 8 non-critical
    • Not serious Non-critical

      SAFETY DATA SHEET

      Safety data sheets were not available for the pool test chemicals.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 39 ppm and the pool is not balanced. Langlier index was at -0.8.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      Monthly reports were not being completed and submitted on a monthly basis.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      The free chlorine level was at 0.15 ppm. The minimum level of chlorine with an ORP reading between 650-900 mV is 1.0 ppm. If the ORP reading is outside of 650-900 mV then the chlorine level must be at 2.0 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A. The pool must remain closed until the chlorine level reaches the minimum level. Chlorine concentration may not exceed 10 ppm.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

  5. Jun 1, 2023 Routine · 4 non-critical
    • Not serious Non-critical

      PERMIT NOT POSTED

      The permit is not posted in a place visible to the public.

      Correction: Post the permit in public view.

      Code ATCP 76.05(7)

    • Not serious Non-critical

      MSDS AVAILABILITY

      Material safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide material safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Non-critical

      CYANURIC ACID >30 PPM

      The cyanuric acid concentration is 116 ppm.

      Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.

      Code ATCP 76.14(4)(b)

    • Not serious Non-critical

      COMBINED CHLORINE

      The combined chlorine is 0.8 ppm.

      Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.

      Code ATCP 76.14(4)(e)

Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.