RecordWell Data

Meadowbrook Country Club

2149 N GREENBAY RD, Racine, WI 53405 · Racine County

24cited violations
3serious tier
5inspections

Establishment

Type
Pool / recreational water (Pool - Moderate with Features)
Inspected by
Central Racine County Health Department
License / ID
PSVN-8G2JS3
Status
Permitted
Phone
ext. Jason
Official record
Central Racine County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026271
2025152
2024160
2023160

Inspections

  1. Jul 30, 2026 Admin Follow Up · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter gauges marks are worn and difficult to read and operator stated it gets stuck from time to time. Appears around 400gpm.

      Correction: Replace flowmeter with new unit that is legible. It is recommended to install in center of a long pipe to get an accurate reading.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool. Email copy upon completion.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have VGBA documentation available during inspection. Main drain grates were replaced prior to this season. Drains appear identical to the older grates kept in LG room.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover. Provide affidavit and receipt for the drain grates installed.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

  2. Jul 15, 2026 Routine · 1 critical, 3 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flow meter gauges marks are worn and difficult to read and operator stated it gets stuck from time to time. Appears around 400gpm.

      Correction: Replace flowmeter with new unit that is legible. It is recommended to install in center of a long pipe to get an accurate reading.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool. Email copy upon completion.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have VGBA documentation available during inspection. Main drain grates were replaced prior to this season. Drains appear identical to the older grates kept in LG room.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover. Provide affidavit and receipt for the drain grates installed.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      RING BOUY

      A ring buoy not provided.

      Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less. A ring bouy shall be provided for each life guard chair. Please text or email photo of ring bouy when in place.

      Code ATCP 76.26(1)(b)2.a - RING BOUY

  3. Jul 14, 2025 Routine · 2 critical, 3 non-critical, 1 repeat
    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      OPERATING REPORTS-SAFETY AND RESCUE EQUIPMENT

      Establishment has not submitted monthly reports since 2020.

      Correction: The monthly operating report shall be submitted to the health dept no later than the tenth day of the following month. You may email, mail or text copy of monthly reports to the contact provided during inspection.

      Code ATCP 76.32(1)(g) - SAFETY AND RESCUE EQPT

    • Not serious Non-critical Repeat

      POOL FENCE- 5 FEET HIGH

      The old pool enclosure fence was replaced in 2022 with new fencing that is less than 5 feet (48inches) high. No plan approval was obtained. The replacement of 20 ft or greater requires DSPS plan review and approval. Please contact DSPS for plan review procedure- see link below.

      Correction: The replacement of 20 feet or greater of fencing required DSPS plan review and approval. Contact DSPS for plan review at https://dsps.wi.gov/Pages/Programs/PlanReview/PlumbingPools.aspx Violation has been marked out three consecutive inspection reports. Establishment has 90 days to show proof they have contacted DSPS and provide documentation they have submitted required documents for plan review.

      Code ATCP 76.34(3)(a) - FENCE HEIGHT

    • Serious Critical

      CERTIFICATION MADE AVAILABLE, LIFEGUARD

      For the life guard certifications that are over one year, establishment does not have documentation the CPR/First Aid portion was renewed annually.

      Correction: WI definition for Life Guard states a person holding a current certificate from a course that meets the criteria for lifeguarding, first aid, CPR and AED training and certification set forth in the 2018 Model Aquatic Health Code (MAHC). Per the MAHC, CPR/first aid training shall be completed annually. Make a copy of each certification held by a lifeguard available to the department or its agent. S

      Code ATCP 76.22(2)(a) - LIFEGUARD CERTIFICATIONS AVAILABLE

    • Serious Critical

      SHEPHERD'S CROOK NON-GUARDED POOL, LONG ENOUGH

      The shepherd's crook is not long enough to effect a rescue in the deepest part of pool.

      Correction: Provide a shepherd's crook that is long enough to effect a rescue in deepest part of pool.

      Code ATCP 76.26(1)(b)1.b. - SHEP CROOK LONG ENOUGH NON-GUARDED PO

  4. Jul 12, 2024 Routine · 6 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      CYANURATES 30 PPM LIMIT

      The cyanuric acid concentration is 36 ppm.

      Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.

      Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      SOAP-PROVIDED

      Soap is empty in permanently-installed dispensing device in the women's locker room.

      Correction: Provide soap in a permanently-installed dispensing device.

      Code ATCP 76.33 (2)(e)1. - SOAP

    • Not serious Non-critical

      POOL DECK-DEPTH MARKINGS MAINTAINED

      The depth markings nalongn the interior edge of the pool are fading.

      Correction: Maintain pool deck area so that depth markings along the edge of the pool are clearly visible and readable.

      Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS

    • Not serious Non-critical

      POOL FENCE- 5 FEET HIGH

      The old pool enclosure fence was replaced in 2022 with new fencing that is less than 5 feet high. No plan approval was obtained. The replacement of 20 ft or greater requires DSPS plan review and approval. Please contact DSPS for plan review procedure- see link in notes section of report,

      Correction: Install a fence that is at least 5 feet high.

      Code ATCP 76.34(3)(a) - FENCE HEIGHT

  5. Jul 10, 2023 Routine · 6 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION RATE NOT MET - POOLS

      The swimming pool or combination pool has a maximum turnover rate of greater than 6 hours.

      Correction: Immediately adjust or repair the equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(a)

    • Not serious Non-critical Corrected on site

      OUT OF SOAP

      The soap dispenser in the mens locker room is empty. The soap was refilled during inspection.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

    • Not serious Non-critical Repeat

      TELEPHONE NOT WORKING

      There is no sign in the pool area notifying patrons that the emergency phone is located at the bar.

      Correction: Provide a sign at the pool area notifying patrons to the location of the emergency phone.

      Code [A] ATCP 76.26(2)

    • Not serious Non-critical Repeat

      MONTHLY OPERATION REPORTS NOT SUBMITTED

      Monthly operation reports are not being kept in accordance with ATCP 76.32(1).

      Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).

      Code [A] ATCP 76.32(1)

    • Not serious Non-critical Repeat

      LESS THAN 5-FT. HIGH

      The old pool enclosure fence was replaced in 2022 with new fencing that is less than 5 feet high. No plan approval was obtained. The replacement of 20 ft or greater of fencing requires DSPS plan review and approval. Before makign any additioinal changes to the fence, please contact DSPS for plan review procedure- see link in notes section of report.

      Correction: Replace or extend the enclosure so that it complies with ATCP 76.34(3).

      Code [A] ATCP 76.34(3)

    • Not serious Non-critical

      DEPTH MARKINGS FADED

      The depth markings along the interior edge of the pool are fading.

      Correction: Repair the markings so they are clearly visible and readable.

      Code [B] ATCP 76.33(1)(b)

Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.