Image Management Family Branch YMCA
8501 CAMPUS DR, Mt Pleasant, WI 53406 · Racine County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Central Racine County Health Department
- License / ID
- KHES-8XGN7A
- Status
- Permitted
- Phone
- (262) 880-ance
- Official record
- Central Racine County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 1 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 3 | 2 |
| 2023 | 2 | 7 | 0 |
Inspections
-
Apr 7, 2026 Routine · 1 critical, 2 non-critical
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 634 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Serious
Critical
RING BOUY
A ring buoy not provided at the whirlpool lifeguard chair
Correction: Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Not serious
Non-critical
-
Apr 28, 2025 Routine · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
-
Apr 17, 2024 Routine · 2 critical, 1 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
-
Jun 9, 2023 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE
The combined chlorine is 1.21.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Non-critical
Repeat
MAXIMUM PATRON LOAD NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load in accordance with ATCP 76.29(1)(d).
Code [A] ATCP 76.29(1)(d)
-
Not serious
Non-critical
Repeat
MONTHLY OPERATION REPORTS NOT SUBMITTED
Monthly operation reports are not being kept in accordance with ATCP 76.32(1).
Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).
Code [A] ATCP 76.32(1)
-
Not serious
Non-critical
Repeat
-
May 19, 2023 Routine · 4 non-critical, 2 repeat
-
Not serious
Non-critical
COMBINED CHLORINE
The combined chlorine is 1.21.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Non-critical
Repeat
TELEPHONE NOT WORKING
The emergency telephone does not work..
Correction: Provide a functional emergency telephone immediately. .
Code [A] ATCP 76.26(2)
-
Not serious
Non-critical
MAXIMUM PATRON LOAD NOT POSTED
The maximum patron load is not posted in the facility.
Correction: Post the maximum patron load in accordance with ATCP 76.29(1)(d).
Code [A] ATCP 76.29(1)(d)
-
Not serious
Non-critical
Repeat
MONTHLY OPERATION REPORTS NOT SUBMITTED
Monthly operation reports are not being kept in accordance with ATCP 76.32(1).
Correction: Keep monthly operation reports in accordance with ATCP 76.32(1).
Code [A] ATCP 76.32(1)
-
Not serious
Non-critical
Source: Central Racine County Health Department. History last read Oct 16, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.