  1. Mar 5, 2026 Routine · 1 critical, 2 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met under 6 hours. Turnover rate was 7 hours.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. The are cracks along the south deck of the pool and chipping paint on pool basin floor.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Serious Critical

      PH

      The pH is 8.0 on Spin Disk. Discussed plan to get in better pH range.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  2. Dec 4, 2024 Routine · 3 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN ACTION LEVEL

      The combined chlorine plan does not include the combined chlorine action level.

      Correction: Includes the combined chlorine action level in the combined chlorine plan.

      Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents are expired for the alkalinity test.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      SOAP-PROVIDED

      Soap not provided in permanently-installed dispensing device in the mens and womans showers.

      Correction: Provide soap in a permanently-installed dispensing device.

      Code ATCP 76.33 (2)(e)1. - SOAP

  3. Dec 12, 2023 Follow Up · 2 non-critical, 2 repeat
    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN ACTION LEVEL

      There is no combined chlorine plan available onsite.

      Correction: Develop a combined chlorine plan for the pool. Template provided during inspection.

      Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

  4. Dec 12, 2023 Routine · 1 critical, 2 non-critical
    • Not serious Non-critical

      COMBINED CHLORINE PLAN ACTION LEVEL

      There is no combined chlorine plan available onsite.

      Correction: Develop a combined chlorine plan for the pool. Template provided during inspection.

      Code ATCP 76.14(5)(e)2.a. - ACTION LEVEL LISTED

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises:

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Serious Critical

      TELEPHONE ACCESSIBLE

      The emegency telephone is not operational during inspection.

      Correction: Pool must close until emergency telephone is repaired and operational. Provide a working telephone or other technology capable of connecting with emergency services. Notify once repaired and operational.

      Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE