Summit Lake Campground & Rv Park
3926 MARSH LAKE RD, Stone Lake, WI 54876 · Sawyer County
Establishment
- Type
- Campground (Campground 51-100 Sites (RC3))
- Inspected by
- Sawyer County Health & Human Services
- License / ID
- DROS-98W7B3
- Status
- Permitted
- Official record
- Sawyer County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 0 |
| 2025 | 1 | 1 | 0 |
| 2023 | 1 | 1 | 0 |
Inspections
-
Aug 27, 2026 Routine · 3 non-critical
-
Not serious
Non-critical
Site designation
Campsite 77, yurt site is not clearly marked with an alpha or numeric symbol that is a minimum of 2 inches in height and visible from the campground’s internal road system.
Correction: Provide each campsite with a clearly marked alpha or numeric symbol that is a minimum of 2 inches in height and visible from the campground’s internal road system.
Code ATCP 79.11 (2)
-
Not serious
Non-critical
Operator-provided unit-bunk bed separation
Bunk bed(s) in operator-provided camping unit - site 77 yurt does not have 2.5 foot (30 inch) vertical separation from the top of the lower mattress to the frame of the upper bunk
Correction: Redesign bunk beds so that [there are no more than 2 stacked, so that there is a 2.5 foot vertical separation from the top of the lower mattress to the bottom of the frame of the upper bed or so that there is at least 2.5 feet of free space above the mattress of the upper bed] or remove bunk beds.
Code ATCP 79.13 (8) (a)
-
Not serious
Non-critical
Operator-provided unit-bunk bed constructed, maintained
Bunk bed constructed after June 19, 2001 observed to need 30 inches clearance between top of lower mattress and bottom of bunk. Bunk rail of top bunk must be 5 inches above mattress
Correction: Remodel or replace bunk bed or mattresses to meet the requirements of 16 CFR 1513.
Code ATCP 79.13 (8) (b)
-
Not serious
Non-critical
-
Sep 11, 2025 Routine · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
Water system-backflow protection
1 site out of 6 has backflow prevention devices.
Correction: Please evaluate the 80 sites and provide backflow prevention. Provide water service connections with approved backflow prevention devices.
Code ATCP 79.14 (4) (c)
-
Not serious
Non-critical
Repeat
-
Aug 29, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
Water system-backflow protection
Water service connection for most units not provided with approved backflow prevention devices.
Correction: Provide water service connections with approved backflow prevention devices. Provide a system for assuring campers have back flow prevention for their units.
Code ATCP 79.14 (4) (c)
-
Not serious
Non-critical
Source: Sawyer County Health & Human Services. History last read Oct 17, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.