Jun 23, 2026 Pre-inspection · 7 non-critical
-
Serious
Critical
Smoke alarms provided
Smoke alarms are not provided within each individually keyed unit.
Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.
Code ATCP 72.18(11)(a)
-
Serious
Critical
Smoke alarm maintained - working order; expiration
The smoke alarm in the two bedroom cabin is expired
Correction: Repair or replace the smoke alarm within 5 calendar days.
Code ATCP 72.18(11)(e)
-
Serious
Critical
Carbon monoxide alarms provided
A carbon monoxide alarm is not provided anywhere in the lodging facility that also contains a fuel-burning appliance.
Correction: Provide carbon monoxide alarms at the locations specified in rule.
Code ATCP 72.18(12)(a)
-
Serious
Critical
Carbon monoxide alarm maintained - working order; expiration
The carbon monoxide alarm in 2 bedroom cabin, in the hallway, outside of the sleeping room cluster is expired.]
Correction: Repair or replace the carbon monoxide alarm within 5 calendar days.
Code ATCP 72.18(12)(h)
-
Serious
Critical
Bunk beds - guards not provided
The upper bunk bed is not provided with permanently installed guards on the long side of the bunk bed.
Correction: Provide guard and rotate the bed along the wall and provide access to the window for egress.
Code ATCP 72.18(3)(d)4.
-
Not serious
Priority Foundation
Smoke alarm installed in each sleeping room
A smoke alarm is not within each sleeping room. 3 bedroom cabin and 2 bedroom cabin does not have any smoke detectors in bedrooms.
Correction: Provide a smoke alarm within each sleeping room.
Code ATCP 72.18(11)(b)3.
-
Not serious
Priority Foundation
Building evacuation diagram (TRH) - posted or provided
The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.
Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.
Code ATCP 72.18(6)(b)1.
-
Serious
Critical