Americinn Hayward - Swimming Pool
15601 US HWY 63, Hayward, WI 54843 · Sawyer County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Sawyer County Health & Human Services
- License / ID
- ENEY-A53P2M
- Status
- Permitted
- Official record
- Sawyer County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 2 | 3 | 2 |
| 2024 | 4 | 20 | 9 |
Inspections
-
Nov 13, 2025 Routine · No items found
No violations cited.
-
Feb 26, 2025 Routine · 2 critical, 1 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Serious
Critical
INTERLOCK LOG-INFORMATION
The monthly testing was not logged on the daily log.
Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.
Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
-
Aug 13, 2024 Follow Up · 1 critical, 3 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Water samples were collected only for two days out of 9 days open.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
Repeat
OPERATOR RESPONSIBILITIES
The operator has not been responsible for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality . Daily water quality was not checked according to the daily log.
Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Daily water sample results not collected or recorded.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Serious
Critical
Repeat
RESPONSIBLE SUPERVISOR AVAILABLE AND RESPOND
The responsible supervisor is off premise and cannot respond to a unsafe condition in 15 minutes or less.
Correction: Have the responsible supervisor respond within 15 minutes when action is needed. A person in charge of the pool should be established for each shift that the pool is open or the pool should be closed.
Code ATCP 76.21 (1)(b) - NOT AVAILABLE WITHIN 15 MINUTES
-
Not serious
Non-critical
Repeat
-
Jul 29, 2024 Re-inspection · 1 critical, 3 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
OPERATOR RESPONSIBILITIES
The operator has not been responsible for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality . Daily water quality was not checked according to the daily log.
Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
Repeat
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Water samples were collected only for two days out of 9 days open.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Daily water sample results not collected or recorded.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Serious
Critical
Repeat
RESPONSIBLE SUPERVISOR AVAILABLE AND RESPOND
The responsible supervisor is off premise and cannot respond to a unsafe condition in 15 minutes or less.
Correction: Have the responsible supervisor respond within 15 minutes when action is needed. A person in charge of the pool should be established for each shift that the pool is open or the pool should be closed.
Code ATCP 76.21 (1)(b) - NOT AVAILABLE WITHIN 15 MINUTES
-
Not serious
Non-critical
Repeat
-
Jul 10, 2024 Routine · 4 critical, 3 non-critical
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Water samples were collected only for two days out of 9 days open.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
OPERATOR RESPONSIBILITIES
The operator has not been responsible for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality . No chemical addtition have been done to correct the PH and Chlorine levels
Correction: Provide a pool operator who is responsible and providing active managerial control for equipment shut-down, backwashing, daily maintenance and vacuuming, and maintenance of water quality.
Code ATCP 76.20(1)(b) - OPERATOR RESPONSIBILITIES
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Daily water sample results not collected or recorded.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Serious
Critical
RESPONSIBLE SUPERVISOR AVAILABLE AND RESPOND
The responsible supervisor is off premise and cannot respond to a unsafe condition in 15 minutes or less.
Correction: Have the responsible supervisor respond within 15 minutes when action is needed. A person in charge of the pool should be established for each shift that the pool is open or the pool should be closed.
Code ATCP 76.21 (1)(b) - NOT AVAILABLE WITHIN 15 MINUTES
-
Serious
Critical
CLOSING CRITERIA-FAILURE TO MEET 76.16
The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. PH and Chlorine level were <1.0 and PH was 8.0.
Correction: Close the pool in the event of failure to comply with the water quality requirements pursuant to s. ATCP 76.16.
Code ATCP 76.30 (1)(b) - FAILURE TO MEET ATCP 76.16
-
Serious
Critical
CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS
The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. Pool was sampled two days in July and both days the free chlorine was less than 1.0 ppm and PH was 8.0.
Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.
Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14
-
Serious
Critical
CLOSING CRITERIA-NO RESPONSIBLE SUPERVISOR
The operator has not closed the pool due to the absence or non−availability of a responsible supervisor.
Correction: Close the pool in the event of absence or non−availability of a responsible supervisor.
Code ATCP 76.30 (1)(f) - NO RESPONSIBLE SUPERVISOR
-
Not serious
Non-critical
-
Apr 4, 2024 Routine · 3 critical, 2 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
TEST KIT APPROVED
Test kit did not have proper reagents
Correction: Reagents were obtained by over night delivery
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Serious
Critical
INTERLOCK LOG-INFORMATION
The monthly testing log is missing or incomplete. Interlock testing not recorded.
Correction: Maintain a log that is documented with the date, results, and the name of the person performing the interlock test.
Code ATCP 76.13 (1)(c)4.a - INTERLOCK LOG, INFORMATION REQUIRED
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Serious
Critical
GATES AND DOORS-LATCHING
The gate or door does not latch/lock.
Correction: Provide a latching door.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
Source: Sawyer County Health & Human Services. History last read Oct 17, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.