RecordWell Data

Luck Country Inn Whirlpool

10 ROBERTSON RD, Luck, WI 54853 · Polk County

21cited violations
7serious tier
6inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Polk County Health Department
License / ID
HSAT-7QX3L5
Status
Permitted
Phone
(715) 472-2000
Official record
Polk County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026120
20253116
2024131
2023150

Inspections

  1. Mar 23, 2026 Routine · 2 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers not repaired or replaced as needed.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE

      The FLOWMETER is not installed according to manufacturer instructions or as verified by pump curve. [Describe].

      Correction: Install the [ ] according to manufacturer instructions or as verified by pump curve.

      Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO

  2. Sep 12, 2025 Routine · No items found

    No violations cited.

  3. Jul 11, 2025 Routine · No items found

    No violations cited.

  4. Apr 16, 2025 Routine · 6 critical, 5 non-critical, 2 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE

      The flowmeter is not installed.

      Correction: Install the flowmeter according to manufacturer instructions or as verified by pump curve.

      Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO

    • Not serious Non-critical Repeat

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Whirlpool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY

      Whirlpool water is not being recorded onece testing is done weekly.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Serious Critical Repeat

      PH

      The pH is 8.6.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      MAXIMUM BROMINE

      The maximum total bromine exceeds 10 ppm.

      Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.

      Code ATCP 76.14(5)(g) -MAXIMUM BROMINE

    • Serious Critical

      WHIRLPOOL WATER TEMPERATURE

      The whirlpool water temperature is 106°F.

      Correction: Maintain the whirlpool water at greater than 90°F or 32°C, and may not exceed 104°F or 40°C.

      Code ATCP 76.19(4)(c) - WHIRLPOOL WATER TEMP

    • Serious Critical

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical

      CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS

      The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. PH is 8.4 and Bromine is at 41.11 ppm. Both are grounds for pool closure.

      Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.

      Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14

    • Serious Critical

      GATES AND DOORS-SELF-CLOSING

      The gates do not self-close.

      Correction: Provide a self-closing gate or door.

      Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING

  5. Mar 12, 2024 Routine · 1 critical, 2 non-critical
    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Spa water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Serious Critical

      PH

      The pH is 8.4.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

  6. Jun 30, 2023 Routine · 5 non-critical
    • Not serious Non-critical

      SKIMMERS NOT FUNCTIONING

      The skimmers are not adequately removing surface debris. Water level is too high. Wiers cannot skim surface water if they are completely submerged.

      Correction: Readjust the flow through the skimmers to maintain vigorous skimming action through all skimmers.

      Code ATCP 76.11(2)(a)

    • Not serious Non-critical

      pH OUT OF BALANCE

      The pH is 8.4.

      Correction: Do not reopen it until the pH falls between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Non-critical

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 219.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Non-critical

      WHIRLPOOL WATER TEMPERATURE

      The temperature of the whirlpool water is 105ºF degrees Fahrenheit.

      Correction: Adjust the temperature to bring it within permissible limits pursuant to ATCP 76.19(4)(c).

      Code ATCP 76.19(4)(c)

    • Not serious Non-critical

      BROMINE TOO LOW

      The bromine residual was 1.0 at the time of the inspection.

      Correction: Close the pool and raise the bromine residual to 3.0 before re-opening.

      Code [B] ATCP 76.14(4)(a)

Source: Polk County Health Department. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.