The Windsor
155 DEVONSHIRE CT, Plover, WI 54467 · Portage County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Portage County Health & Human Services
- License / ID
- SYOG-7QS28W
- Status
- Permitted
- Phone
- (715) 295-9300
- Official record
- Portage County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 1 |
| 2025 | 1 | 1 | 1 |
| 2024 | 1 | 9 | 1 |
| 2023 | 1 | 3 | 0 |
Inspections
-
Jul 30, 2026 Routine · 1 critical, 2 non-critical
-
Not serious
Non-critical
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 48 ppm
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 600 mV. The pool water is tested manually once per day.
Correction: Maintain water potential between 650−900 mV, and manually test the water at a minimum of twice per day if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Serious
Critical
TELEPHONE ACCESSIBLE
The telephone in the pool area is not working.
Correction: Provide a working telephone or other technology capable of connecting with emergency services. A temporary phone is available in adjacent clubhouse.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
-
Aug 14, 2025 Routine · 1 critical
-
Serious
Critical
RING BOUY
The ring buoy is not maintained in good repair, buoy is cracked.
Correction: Replace damaged ring buoy. Provide a ring buoy with rope a length not less than 1-1/2 times the maximum width of the pool or 50 feet, whichever is less.
Code ATCP 76.26(1)(b)2.a - RING BOUY
-
Serious
Critical
-
Aug 14, 2024 Routine · 1 critical, 8 non-critical
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is not conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
DOORS
Doors to chemical storage area is not locked and marked to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
EMERGENCY CONTACT PHONE NUMBERS
Emergency contact phone numbers are not in the chemical storage area or readily accessible.
Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.
Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS
-
Not serious
Non-critical
SAFETY DATA SHEET
Material safety data sheets are not available for pool chemical, (chlorine tablets and acid)
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 50 ppm.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POOL RULES SIGNAGE-SHOWER
Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Code ATCP 76.29(1)(b)1.c. - SHOWER
-
Not serious
Non-critical
POOL RULES SIGNAGE-NO DIAPER CHANGING ON DECK
Pool rules missing rule: Diaper changing on the pool deck is prohibited.
Correction: Include pool rule on sign: Diaper changing on the pool deck is prohibited.
Code ATCP 76.29(1)(b)1.f. - NO DIAPER CHANGING ON DECK
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jul 19, 2023 Routine · 3 non-critical
-
Not serious
Non-critical
WATER TESTING FREQUENCY - POOLS
The water testing frequency for cyanuric acid is not in compliance with ATCP 76.18(1).
Correction: Perform water testing in accordance with ATCP 76.18(1).
Code ATCP 76.18(1)
-
Not serious
Non-critical
IN NEED OF CLEANING
An area of the pool concrete deck requires repair to fill gap.
Correction: Repair concrete on pool deck.
Code [A] ATCP 76.33(1)(a)
-
Not serious
Non-critical
DRINKING FOUNTAIN NOT FUNCTIONAL
The drinking fountain on pool deck is not functional.
Correction: Repair the drinking fountain.
Code [A] ATCP 76.33(1)(g)
-
Not serious
Non-critical
Source: Portage County Health & Human Services. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.