Stevens Point Municipal (wading Pool)
2442 SIMS AVE, Stevens Point, WI 54481 · Portage County
Establishment
- Type
- Pool / recreational water (Pool - Simple with Features)
- Inspected by
- Portage County Health & Human Services
- License / ID
- SYOG-7QS22Q
- Status
- Permitted
- Phone
- (715) 346-1226
- Official record
- Portage County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 1 |
| 2025 | 1 | 2 | 0 |
| 2024 | 1 | 7 | 1 |
| 2023 | 1 | 3 | 0 |
Inspections
-
Jun 2, 2026 Routine · 1 critical, 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 40 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Serious
Critical
OUTDOOR POOL MINIMUM WATER TEMPERATURE
The outdoor pool water temperature is 63°F.
Correction: Maintain the outdoor pool water at a minimum of 65°F or 18°C.
Code ATCP 76.19(4)(b) 2 - OUTDOOR POOL WATER TEMP
-
Not serious
Non-critical
Repeat
-
Jun 4, 2025 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 30 ppm..
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool seal, spray feature has corroded surfaces that require repair.
Correction: Maintain the pool equipment, repair/patch corroded surfaces on seal.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Not serious
Non-critical
Repeat
-
May 30, 2024 Routine · 1 critical, 6 non-critical
-
Not serious
Non-critical
DOORS
Doors to chemical storage areas not locked and marked to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
SAFETY DATA SHEET BACKUP
A backup copy of the safety data sheets was not available.
Correction: Maintain a backup copy of safety data sheets for each chemical on site.
Code ATCP 76.12 (4)(b)2. - SAFETY SATE SHEETS, BACKUP COPY
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 572 mV. Note: Water is being tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
FIRST AID KIT-ELASTIC BANDAGE
The first aid kit is missing an elastic bandage.
Correction: Provide an elastic bandage for the first aid kit.
Code ATCP 76.27(1)(b)6. - ELASTIC BANDAGE
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. A leak is observed in the plumbing/pressure line of the baby pool circulation system.
Correction: Maintain the pool equipment, repair leak.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jun 7, 2023 Routine · 3 non-critical, 1 repeat
-
Not serious
Non-critical
pH OUT OF BALANCE
The pH is 7.0.
Correction: Maintain pH level between 7.2 and 7.8.
Code ATCP 76.14(4)(c)
-
Not serious
Non-critical
Repeat
ALKALINITY OUT OF BALANCE
The total alkalinity is 30.
Correction: Maintain the total alkalinity between 60 and 180 ppm.
Code ATCP 76.14(4)(d)
-
Not serious
Non-critical
OUT OF SOAP
The soap dispenser in boys and girls shower rooms are empty.
Correction: Provide soap at all hand washing sinks and showers.
Code ATCP 76.33(2)(e)
-
Not serious
Non-critical
Source: Portage County Health & Human Services. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.