RecordWell Data

Stevens Point Municipal (wading Pool)

2442 SIMS AVE, Stevens Point, WI 54481 · Portage County

14cited violations
2serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Simple with Features)
Inspected by
Portage County Health & Human Services
License / ID
SYOG-7QS22Q
Status
Permitted
Phone
(715) 346-1226
Official record
Portage County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026121
2025120
2024171
2023130

Inspections

  1. Jun 2, 2026 Routine · 1 critical, 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Serious Critical

      OUTDOOR POOL MINIMUM WATER TEMPERATURE

      The outdoor pool water temperature is 63°F.

      Correction: Maintain the outdoor pool water at a minimum of 65°F or 18°C.

      Code ATCP 76.19(4)(b) 2 - OUTDOOR POOL WATER TEMP

  2. Jun 4, 2025 Routine · 2 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 30 ppm..

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The pool seal, spray feature has corroded surfaces that require repair.

      Correction: Maintain the pool equipment, repair/patch corroded surfaces on seal.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

  3. May 30, 2024 Routine · 1 critical, 6 non-critical
    • Not serious Non-critical

      DOORS

      Doors to chemical storage areas not locked and marked to indicate entry is for authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      SAFETY DATA SHEET BACKUP

      A backup copy of the safety data sheets was not available.

      Correction: Maintain a backup copy of safety data sheets for each chemical on site.

      Code ATCP 76.12 (4)(b)2. - SAFETY SATE SHEETS, BACKUP COPY

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 572 mV. Note: Water is being tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      FIRST AID KIT-ELASTIC BANDAGE

      The first aid kit is missing an elastic bandage.

      Correction: Provide an elastic bandage for the first aid kit.

      Code ATCP 76.27(1)(b)6. - ELASTIC BANDAGE

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The pool equipment is not properly maintained. A leak is observed in the plumbing/pressure line of the baby pool circulation system.

      Correction: Maintain the pool equipment, repair leak.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Serious Critical

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  4. Jun 7, 2023 Routine · 3 non-critical, 1 repeat
    • Not serious Non-critical

      pH OUT OF BALANCE

      The pH is 7.0.

      Correction: Maintain pH level between 7.2 and 7.8.

      Code ATCP 76.14(4)(c)

    • Not serious Non-critical Repeat

      ALKALINITY OUT OF BALANCE

      The total alkalinity is 30.

      Correction: Maintain the total alkalinity between 60 and 180 ppm.

      Code ATCP 76.14(4)(d)

    • Not serious Non-critical

      OUT OF SOAP

      The soap dispenser in boys and girls shower rooms are empty.

      Correction: Provide soap at all hand washing sinks and showers.

      Code ATCP 76.33(2)(e)

Source: Portage County Health & Human Services. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.