RecordWell Data

Holiday Inn Express (pool)

1100 AMBER AVE, Stevens Point, WI 54482 · Portage County

13cited violations
3serious tier
3inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Portage County Health & Human Services
License / ID
CHES-C9BKM3
Status
Permitted
Phone
(715) 344-0000
Official record
Portage County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026100
2024193
2023140

Inspections

  1. Jun 25, 2026 Routine · No items found

    No violations cited.

  2. Nov 5, 2024 Routine · 3 critical, 6 non-critical
    • Not serious Non-critical

      INLETS CHECKED AND ADJUSTED

      The inlet (eyeball) fittings are missing from the pool wall Inlets, a uniform pattern of distribution does not occur.

      Correction: Replace missing fittings and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.

      Code ATCP 76.11(2)(c) - INLETS POSITIONED

    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition. Flowmeter is not functional.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      BACKWASH PROCEDURES POSTED ON EASILY READ CHART

      The backwash procedure is not conspicuously posted on an easily read chart.

      Correction: Post the backwash procedure on an easily read chart.

      Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED

    • Not serious Non-critical

      DOORS

      Doors to chemical storage areas are not marked to indicate entry is for authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      BIOHAZARD KIT-PAPER TOWELING

      The biohazard kit is missing paper toweling.

      Correction: For the biohazard kit, provide paper toweling.

      Code ATCP 76.27(2)(b)5 - PAPER TOWELS

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Serious Critical

      Modification(s) made but no DSPS Approval available for them.

      The operator modified a pool and did not submit pool construction plans to DSPS for review and approval. Pool deck was recently refinished.

      Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool.

      Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided. Drinking fountain was removed from pool enclosure since last inspection.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

    • Serious Critical

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. VGBA main drain covers and equilizer wall covers have expired. Note: covers appear to be in good condition.

      Correction: Correct the hazardous condition, replace expired VGBA covers.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

  3. Sep 11, 2023 Routine · 4 non-critical
    • Not serious Non-critical

      DIRECTION OF FLOW NOT LABELED

      The water treatment system piping is not marked with a permanent label indicating direction of flow. Note: a few labels are missing on piping, replace missing labels to indicate flow of water.

      Correction: Mark the water treatment system piping to indicate direction of flow.

      Code ATCP 76.11(5m)

    • Not serious Non-critical

      CHLORINE TOO HIGH

      The chlorine residual exceeded 10 ppm.

      Correction: The pool must be closed and may not reopen until the chlorine residual comes into an acceptable range.

      Code ATCP 76.14(4)(f)

    • Not serious Non-critical

      TELEPHONE NOT WORKING

      The emergency telephone does not work.

      Correction: Provide a functional emergency telephone immediately.

      Code [A] ATCP 76.26(2)

    • Not serious Non-critical

      FIRST AID SUPPLIES MISSING

      An elastic bandage is missing from the first aid kit.

      Correction: Provide all the items listed in ATCP 76.27(1) in the first aid kit.

      Code [C] ATCP 76.27(1)

Source: Portage County Health & Human Services. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.