Country Inn & Suites (whirlpool)
301 DIVISION ST N, Stevens Point, WI 54481 · Portage County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Portage County Health & Human Services
- License / ID
- CHES-DP9QXG
- Status
- Permitted
- Phone
- (715) 345-7000
- Official record
- Portage County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 3 | 10 | 2 |
| 2025 | 1 | 7 | 1 |
Inspections
-
Feb 25, 2026 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
SOAP-PROVIDED
Soap not provided in permanently-installed dispensing device at the showers in pool enclosure.
Correction: Provide soap in a permanently-installed dispensing device.
Code ATCP 76.33 (2)(e)1. - SOAP
-
Not serious
Non-critical
Repeat
-
Feb 13, 2026 Re-inspection · 1 critical, 2 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 30 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
SOAP-PROVIDED
Soap not provided in permanently-installed dispensing device at the showers in pool enclosure.
Correction: Provide soap in a permanently-installed dispensing device.
Code ATCP 76.33 (2)(e)1. - SOAP
-
Serious
Critical
PH
The pH is below 7.0.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
-
Jan 27, 2026 Follow Up · 1 critical, 5 non-critical
-
Not serious
Non-critical
DOORS
Doors to chemical storage areas not locked and marked to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
FIRST AID KIT-ADHESIVE BANDAGES
The first aid kit is missing adhesive bandages.
Correction: Provide adhesive bandages for the first aid kit.
Code ATCP 76.27(1)(b)2. - ADHESIVE BANDAGES
-
Not serious
Non-critical
FIRST AID KIT-ADHESIVE TAPE
The first aid kit is missing adhesive tape.
Correction: Provide adhesive tape for the first aid kit.
Code ATCP 76.27(1)(b)4. - ADHESIVE TAPE
-
Not serious
Non-critical
FIRST AID KIT-INSTANT COLD PACKS
The first aid kit is missing instant cold packs.
Correction: Provide instant cold packs for the first aid kit.
Code ATCP 76.27(1)(b)9. - INSTANT COLD PACKS
-
Serious
Critical
MAXIMUM CHLORINE
The maximum chlorine residual exceeds 10 ppm. Chlorine level is at 19.6 ppm
Correction: Close the pool until the chlorine residual is in compliance with ATCP 76.14 Table A. Note: whirlpool was closed at time of inspection, whirlpool may not reopen until levels are within 3.00 ppm and 10.00 ppm chlorine.
Code ATCP 76.14(5)(f) - MAXIMUM FREE CHLORINE
-
Not serious
Non-critical
-
Dec 11, 2025 Pre-inspection · 1 critical, 6 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
The skimmer float valve in the whirlpool requires replacement. The tear drop slide valve is broken off.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
DOORS
Doors to chemical storage areas not locked and marked to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
FIRST AID KIT-ADHESIVE BANDAGES
The first aid kit is missing adhesive bandages.
Correction: Provide adhesive bandages for the first aid kit.
Code ATCP 76.27(1)(b)2. - ADHESIVE BANDAGES
-
Not serious
Non-critical
FIRST AID KIT-ADHESIVE TAPE
The first aid kit is missing adhesive tape.
Correction: Provide adhesive tape for the first aid kit.
Code ATCP 76.27(1)(b)4. - ADHESIVE TAPE
-
Not serious
Non-critical
FIRST AID KIT-INSTANT COLD PACKS
The first aid kit is missing instant cold packs.
Correction: Provide instant cold packs for the first aid kit.
Code ATCP 76.27(1)(b)9. - INSTANT COLD PACKS
-
Not serious
Non-critical
WALLS, CEILINGS, FLOORS
The non slip strips on the inclined flooring area at the pool entrance are not maintained in good repair.
Correction: Replace the non slip strips that are peeling to provide surfaces that are in good repair and in clean and sanitary condition.
Code ATCP 76.33(1)(c) - FLOORS, WALLS, CEILINGS
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
Source: Portage County Health & Human Services. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.