Adventure 212 Fitness, LLC (pool)
3217 JOHN JOANIS, Stevens Point, WI 54481 · Portage County
Establishment
- Type
- Pool / recreational water (Pool - Moderate with Features)
- Inspected by
- Portage County Health & Human Services
- License / ID
- SYOG-7QS28D
- Status
- Permitted
- Phone
- (715) 343-0212
- Official record
- Portage County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 1 |
| 2025 | 1 | 11 | 3 |
| 2024 | 2 | 21 | 4 |
Inspections
-
May 28, 2026 Routine · 1 critical, 6 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
SAFETY DATA SHEET
Safety data sheets are not available for pool chemicals (including sodium hypochlorite and sulfuric acid).
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED
No lifeguard and attendant staffing plan is available.
Correction: Prepare and maintain a lifeguard staffing plan.
Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
Repeat
ELECTRICAL GOOD REPAIR
The pool lights are not in operating condition.
Correction: Maintain electrical equipment and lighting in good repair and in operating condition.
Code ATCP 76.33(4)(c) - GOOD REPAIR
-
Serious
Critical
LIFEGUARD AND ATTENDANT STAFFING REQUIREMENTS, TABLES A AND B
The pool is not adequately staffed. No lifeguards are available for instructional programs.
Correction: Provide at least one lifeguard when the instructional program is in session.
Code ATCP 76.23(1)(a)1 - LIFEGUARDS OR ATTENDANTS PRESENT WHERE R
-
Not serious
Non-critical
Repeat
-
Jun 30, 2025 Routine · 3 critical, 8 non-critical, 3 repeat
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
The skimmer weir doors are missing.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flow meter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
SAFETY DATA SHEET
Safety data sheets are not available for pool chemicals, including sodium hypochlorite and sulfuric acid.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 50 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool. Combined chlorine tested at 1.0 ppm.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. See combined chlorine template.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
LIFEGUARD, ATTENDANT STAFFING PLAN REQUIRED
No lifeguard and attendant staffing plan is available for when instructional programs occur in the pool.
Correction: Prepare and maintain a lifeguard staffing plan.
Code ATCP 76.22(1)(a) - LIFEGUARD, ATTENDANT STAFFING PLAN REQUIR
-
Not serious
Non-critical
Repeat
ELECTRICAL GOOD REPAIR
The pool basin lighting is not operational.
Correction: Maintain electrical equipment and lighting in good repair and in operating condition.
Code ATCP 76.33(4)(c) - GOOD REPAIR
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
LIFEGUARD CERTIFICATION, LIFEGUARD
The lifeguard does not have an approved lifeguard certificate. Certifications issued by the American Lifeguard Association are currently not approved in Wisconsin.
Correction: Provide lifeguards who have approved lifeguarding certifications and adjust pool operation or close the pool until adequate lifeguard staffing can be provided.
Code ATCP 76.22(2)(a)1. - LIFEGUARD CERTIFICATION REQUIRED
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Serious
Critical
CO ALARM-POOL AREA
There is a fuel-burning device in the equipment room located in the indoor pool area pool but no functional CO alarm is provided in the indoor pool area.
Correction: Provide a CO alarm in the pool area and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)2- CO ALARM POOL AREA
-
Not serious
Non-critical
-
May 22, 2024 Re-inspection · 6 non-critical, 6 repeat
-
Not serious
Non-critical
Repeat
SAFETY DATA SHEET BACKUP
A backup copy of the safety data sheets was not available.
Correction: Maintain a backup copy of safety data sheets for each chemical on site.
Code ATCP 76.12 (4)(b)2. - SAFETY SATE SHEETS, BACKUP COPY
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool. New code requirement.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair.
Correction: Maintain pool deck area in good repair.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
ELECTRICAL GOOD REPAIR
Pool basin lights are not in operating condition.
Correction: Maintain electrical equipment and lighting in good repair and in operating condition.
Code ATCP 76.33(4)(c) - GOOD REPAIR
-
Not serious
Non-critical
Repeat
-
May 13, 2024 Routine · 4 critical, 11 non-critical
-
Not serious
Non-critical
DOORS
Doors to chemical storage areas not locked and marked to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
SAFETY DATA SHEET BACKUP
A backup copy of the safety data sheets was not available.
Correction: Maintain a backup copy of safety data sheets for each chemical on site.
Code ATCP 76.12 (4)(b)2. - SAFETY SATE SHEETS, BACKUP COPY
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 30 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool. New code requirement.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
The pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Review of pool testing logs indicates pool is not tested on the weekends.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present. New pool code requirement.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair.
Correction: Maintain pool deck area in good repair.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
ELECTRICAL GOOD REPAIR
Pool basin lights are not in operating condition.
Correction: Maintain electrical equipment and lighting in good repair and in operating condition.
Code ATCP 76.33(4)(c) - GOOD REPAIR
-
Serious
Critical
CHEMICAL STORAGE ACCESS RESTRICTED
Chemical storage area access not restricted to authorized personnel. Chemicals containers are currently stored in spa hallway and spa closet.
Correction: Restrict access to chemical storage area to only authorized personnel.
Code ATCP 76.12 (2)(d) - ACCESS RESTRICTED
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
The free chlorine concentration is 0.8 ppm chlorine. Provide a mimimum chlorine concentration of 1.00 ppm.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is 7.0
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
RESPONSIBLE SUPERVISOR FOR POOL
The pool does not have a responsible supervisor. Current pool operator resigned at time of inspection.
Correction: Provide a responsible supervisor for the pool.
Code ATCP 76.21 (1)(a) - RESPONSIBLE SUPERVISOR REQUIRED
-
Not serious
Non-critical
Source: Portage County Health & Human Services. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.