Heritage Apartments
3100 ELLIS ST, Stevens Point, WI 54481 · Portage County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Portage County Health & Human Services
- License / ID
- SYOG-7QS243
- Status
- Permitted
- Phone
- (715) 344-6662
- Official record
- Portage County Health & Human Services inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 1 | 3 | 0 |
| 2024 | 1 | 6 | 1 |
| 2023 | 1 | 2 | 0 |
Inspections
-
Jul 24, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 70 ppm.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
FIRST AID KIT-ELASTIC BANDAGE
The first aid kit is missing an elastic bandage.
Correction: Provide an elastic bandage for the first aid kit.
Code ATCP 76.27(1)(b)6. - ELASTIC BANDAGE
-
Not serious
Non-critical
-
Jul 22, 2025 Routine · 3 non-critical, 1 repeat
-
Not serious
Non-critical
BACKWASH PROCEDURES POSTED ON EASILY READ CHART
The backwash procedure is not conspicuously posted on an easily read chart.
Correction: Post the backwash procedure on an easily read chart.
Code ATCP 76.11(6)(a) 4. - PROCEDURE POSTED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. See attached template.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover. See attached template.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
-
Aug 13, 2024 Routine · 1 critical, 5 non-critical
-
Not serious
Non-critical
DOORS
Doors to chemical storage area is not locked and marked to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
EMERGENCY CONTACT PHONE NUMBERS
Emergency contact phone numbers are not in the chemical storage area or readily accessible.
Correction: Provide emergency contact numbers in the chemical storage area or readily accessible.
Code ATCP 76.12 (2)(j) - EMERGENCY CONTACT PHONE NUMBERS
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheets are not available for pool chemicals used (calcium hypochlorite and acid).
Correction: Maintain safety data sheetsfor each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
CYANURATES 30 PPM LIMIT
The cyanuric acid concentration is 70 ppm.
Correction: Lower the water cyanuric acid concentration to 30 ppm or lower.
Code ATCP 76.14(5)(b)1 - MAXIMUM CYANURIC
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jul 21, 2023 Routine · 2 non-critical, 1 repeat
-
Not serious
Non-critical
FLOWMETER, VALVES AND GAUGES NOT FUNCTIONAL
The flow meter is not functional.
Correction: Repair or replace the specified equipment so an accurate reading can be recorded.
Code ATCP 76.11(5)
-
Not serious
Non-critical
Repeat
CYANURIC ACID >30 PPM
The cyanuric acid concentration is 65 ppm.
Correction: Lower the concentration of cyanuric acid to 30 ppm or lower.
Code ATCP 76.14(4)(b)
-
Not serious
Non-critical
Source: Portage County Health & Human Services. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.