RecordWell Data

Adventure 212 Fitness, LLC (whirlpool)

3217 JOHN JOANIS, Stevens Point, WI 54481 · Portage County

32cited violations
4serious tier
4inspections

Establishment

Type
Pool / recreational water (Pool - Moderate)
Inspected by
Portage County Health & Human Services
License / ID
SYOG-7QS28C
Status
Permitted
Phone
(715) 343-0212
Official record
Portage County Health & Human Services inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026171
2025160
20242193

Inspections

  1. May 28, 2026 Routine · 1 critical, 6 non-critical, 3 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical Repeat

      SAFETY DATA SHEET

      Safety data sheets are not available for pool chemicals including sodium hypochlorite and sulfuric acid.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 50 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Not serious Non-critical

      WHIRLPOOLS-RULES, MINORS UNDER AGE 6

      Signage for whirlpool is missing this rule: Minors under the age of 6 are not permitted in the whirlpool.

      Correction: Include rule stating: Minors under the age of 6 are not permitted in the whirlpool.

      Code ATCP 76.29(3)(e) - NO CHILDREN UNDER 6

    • Serious Critical

      GATES AND DOORS-LATCHING

      The door to the outside does not latch properly. Have to pull bar to securely latch.

      Correction: Provide a latching door.

      Code ATCP 76.34(4)(a)(1m)(b)- LATCHING

  2. Jun 30, 2025 Routine · 6 non-critical, 4 repeat
    • Not serious Non-critical

      SAFETY DATA SHEET

      Safety data sheets are not available for pool chemicals, including sodium hypochlorite and sulfuric acid.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 30 ppm.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      POOL RULES POSTED

      The pool rules are not posted, only whirlpool rules are posted.

      Correction: Post the pool rules.

      Code ATCP 76.29(1)(a)1. - SIGNAGE POSTED

    • Not serious Non-critical Repeat

      ELECTRICAL GOOD REPAIR

      Whirlpool lighting is not functional.

      Correction: Maintain electrical equipment and lighting in good repair and in operating condition.

      Code ATCP 76.33(4)(c) - GOOD REPAIR

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

  3. May 22, 2024 Re-inspection · 7 non-critical, 5 repeat
    • Not serious Non-critical

      POOL BASIN MAINTAINED FREE OF DEFECTS

      Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition.

      Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.

      Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair.

      Correction: Maintain pool deck area in good repair.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Not serious Non-critical Repeat

      SAFETY DATA SHEET BACKUP

      A backup copy of the safety data sheets was not available. New pool code requirement.

      Correction: Maintain a backup copy of safety data sheets for each chemical on site.

      Code ATCP 76.12 (4)(b)2. - SAFETY SATE SHEETS, BACKUP COPY

    • Not serious Non-critical Repeat

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical Repeat

      POOL RULES POSTED

      The pool rules are not posted in whirlpool enclosure. Note: whirlpool signage is currently only posted.

      Correction: Post the pool rules signage 76.29 (1).

      Code ATCP 76.29(1)(a)1. - SIGNAGE POSTED

    • Not serious Non-critical Repeat

      ELECTRICAL GOOD REPAIR

      Whirlpool basin lights are not in operating condition.

      Correction: Maintain electrical equipment and lighting in good repair and in operating condition.

      Code ATCP 76.33(4)(c) - GOOD REPAIR

  4. May 13, 2024 Routine · 3 critical, 9 non-critical
    • Not serious Non-critical

      DOORS

      Doors to chemical storage areas not locked and marked to indicate entry is for authorized personnel only. New pool code requirement.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      SAFETY DATA SHEET BACKUP

      A backup copy of the safety data sheets was not available. New pool code requirement.

      Correction: Maintain a backup copy of safety data sheets for each chemical on site.

      Code ATCP 76.12 (4)(b)2. - SAFETY SATE SHEETS, BACKUP COPY

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 30 ppm

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      ELECTRONIC MONITORING FREQUENCY OF TESTING

      The whirlpool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual. Review of pool logs indicates testing is not done on weekends.

      Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.

      Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ

    • Not serious Non-critical

      POOL RULES POSTED

      The pool rules are not posted in whirlpool enclosure. Note: whirlpool signage is currently only posted.

      Correction: Post the pool rules signage 76.29 (1).

      Code ATCP 76.29(1)(a)1. - SIGNAGE POSTED

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided. New pool code requirement.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      ELECTRICAL GOOD REPAIR

      Whirlpool basin lights are not in operating condition.

      Correction: Maintain electrical equipment and lighting in good repair and in operating condition.

      Code ATCP 76.33(4)(c) - GOOD REPAIR

    • Serious Critical

      CHEMICAL STORAGE ACCESS RESTRICTED

      Chemical storage area access not restricted to authorized personnel. Chemicals are currently stored in the spa hallway and spa closet.

      Correction: Restrict access to chemical storage area to only authorized personnel.

      Code ATCP 76.12 (2)(d) - ACCESS RESTRICTED

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Free available chlorine concentration is 1.8 ppm. Note: minimum chlorine concentration for a whirlpool is 3.00 ppm.

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH is 7.0

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

Source: Portage County Health & Human Services. History last read Oct 19, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.