Juarez (h/s)
1450-1510 W CERMAK RD, Chicago, IL 60608 · Cook County
Establishment
- Type
- Food establishment (School)
- Inspected by
- Chicago Department of Public Health
- License / ID
- 2915819
- Status
- Risk 1 (High)
- Official record
- Chicago Department of Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 1 | 0 |
| 2023 | 2 | 7 | 3 |
| 2022 | 2 | 5 | 1 |
| 2021 | 1 | 1 | 0 |
| 2020 | 1 | 0 | 0 |
| 2019 | 1 | 3 | 0 |
| 2018 | 1 | 4 | 0 |
| 2017 | 3 | 3 | 1 |
| 2016 | 2 | 3 | 1 |
| 2015 | 2 | 11 | 0 |
| 2014 | 2 | 3 | 0 |
| 2013 | 1 | 2 | 0 |
Inspections
-
May 6, 2026 Canvass · Pass — Risk 1 (High)
Result: Pass.
-
Jan 24, 2025 Canvass · Pass — Risk 1 (High)
-
Severity not stated
INSECTS, RODENTS, & ANIMALS NOT PRESENT
6-202.13 OBSERVED STICKY TRAPS SET BY THE FACILITY AROUND THE CONDENSER OF THE WALK IN COOLER. INSTRUCTED TO REMOVE AND ONLY ALLOW PEST CONTROL TO SET ALL TRAPS.
-
Severity not stated
-
Feb 15, 2024 Canvass · Pass — Risk 1 (High)
-
Severity not stated
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
6-501.12 OBSERVED ACCUMULATED DUST DEBRIS ON THE CONDENSER OF THE WALK IN COOLER LOCATED NEXT TO THE HAND WASHING SINK IN THE FOOD PREP AREA AND UNDER THE 3 COMPARTMENT SINK BEHIND THE GREASE TRAP. INSTRUCTED TO CLEAN.
-
Severity not stated
-
Mar 9, 2023 Canvass Re-Inspection · Pass w/ Conditions — Risk 1 (High)
-
Severity not stated
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
6-301.11 OBSERVED NO ACCESS TO HANDWASHING CLEANSER AT THE HANDWASHING SINK IN THE GIRL'S TOILET ROOM. ALL HANDWASHING SINKS MUST BE EQUIPPED WITH HAND-CLEANING LIQUID AT ALL TIMES.7-38-030(C) CITATION ISSUED. THE SOAP DISPENSER WAS REPAIRED AT THE TIME OF INSPECTION.
-
Severity not stated
-
Mar 7, 2023 Canvass · Fail — Risk 1 (High)
-
Serious
Priority
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
FOUND HANDWASHING SINK WATER TEMPERATURE AT 51 - 67F LOCATED IN GIRLS 3RD FLOOR EAST SIDE TOILET ROOM. ALSO NOTED CULINARY ROOM HAND WASHING SINK WATER TEMPERATURE AT 69.6F. INSTRUCTED MANAGER TO PROVIDE A MINIMUM HOT WATER TEMPERATURE OF 100F AT ALL TIMES. PRIORITY VIOLATION. CPS.
-
Not serious
Priority Foundation
Corrected on site
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
OBSERVED NO HAND DRYING PROVISION AT HANDWASHING SINKS LOCATED IN THE MEN'S KITCHEN STAFF TOILET ROOM AND FRONT PREP AREA. ALL HANDWASHING SINKS MUST BE EQUIPPED WITH A HAND DRYING PROVISION AT ALL TIMES. INSTRUCTED MANAGER TO PROVIDE.CORRECTED ON SITE. PRIORITY FOUNDATION. 7-38-030(C), CITATION ISSUED. PAPER TOWEL PROVIDED.
-
Serious
Priority
WAREWASHING FACILITIES: INSTALLED, MAINTAINED & USED; TEST STRIPS
FOUND 3-COMPARTMENT SINK WATER TEMPERATURE IN CULINARY ARTS ROOM AT 74F. INSTRUCTED MANAGER TO PROVIDE A MINIMUM WASH SOLUTION TEMPERATURE OF 110F. PRIORITY VIOLATION. CPS.
-
Serious
Priority
HOT & COLD WATER AVAILABLE; ADEQUATE PRESSURE
OBSERVED INADEQUATE WATER PRESSURE. THERE IS NO RUNNING WATER WHEN HOT WATER AND COLD WATER FAUCET KNOBS ARE TURNED ON IN THE FOLLOWING AREAS: 3 COMP SINKS IN THE CULINARY ARTS ROOM, HANDWASHING SINK IN THE CULINARY ARTS ROOM, PREP SINK IN CULINARY ARTS ROOMS, AT ALL HANDWASHING SINKS IN GIRLS TOILET ROOM ON 3RD FLOOR EAST SIDE OF BUILDING. WATER UNDER PRESSURE SHALL BE PROVIDED TO ALL FIXTURES, EQUIPMENT, AND NONFOOD EQUIPMENT THAT ARE REQUIRED TO USE WATER. PRIORITY VIOLATION. CPS. WATER PRESSURE WAS RESTORED AT THE TIME OF INSPECTION.
-
Severity not stated
SEWAGE & WASTE WATER PROPERLY DISPOSED
FOUND SEWAGE WATER BACKING UP FROM FLOOR DRAIN IN REAR FOOD PREP AREA NEXT TO HANDWASHING SINK WHEN HANDWASHING SINK IS TURNED ON. INSTRUCTED ENGINEER TO REPAIR AND MAINTAIN.
-
Severity not stated
GARBAGE & REFUSE PROPERLY DISPOSED; FACILITIES MAINTAINED
FOUND OUTSIDE GARBAGE RECEPTACLES OPEN. INSTRUCTED MANAGER TO KEEP OUTSIDE GARBAGE RECEPTACLES CLOSED AND TIGHT FITTING AT ALL TIMES. ALSO NOTED IS GARBAGE OUTSIDE ON THE GROUND NEXT TO GARBAGE RECEPTACLES. INSTRUCTED MANAGER TO CLEAN, SANITIZE AND MAINTAIN.
-
Serious
Priority
-
Apr 29, 2022 Canvass Re-Inspection · Pass — Risk 1 (High)
-
Severity not stated
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
5-204.12 UNABLE TO LOCATE THE BACK FLOW PREVENTION DEVICE ON THE ICE MACHINE. INSTRUCTED TO LOCATE OR PROVIDE.
-
Severity not stated
-
Apr 27, 2022 Canvass · Fail — Risk 1 (High)
-
Serious
Priority
HOT & COLD WATER AVAILABLE; ADEQUATE PRESSURE
5-103.11(B) OBSERVED INADEQUATE HOT WATER AT THE HAND WASHING SINKS IN THE PREP AREA AND IN THE EMPLOYEE'S AND ALL OF THE STUDENT TOILET ROOMS, AND AT THE 3 COMPARTMENT SINK, AT THE TIME OF THE INSPECTION HOT WATER AT ALL SINKS RANGED BETWEEN 64F-70F. INSTRUCTED TO PROVIDE ADEQUATE HOT WATER AT ALL SINKS AT ALL TIMES, HOT WATER MUST MAINTAIN AT LEAST 110F AT THE 3 COMPARTMENT SINK AND AT LEAST 100F AT ALL HAND WASHING SINKS IN ALL PREP AREAS AND ALL TOILET ROOMS AT ALL TIMES. PRIORITY VIOLATION 7-38-030(C).
-
Severity not stated
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
5-204.12 UNABLE TO LOCATE THE BACK FLOW PREVENTION DEVICE ON THE ICE MACHINE. INSTRUCTED TO LOCATE OR PROVIDE.
-
Severity not stated
GARBAGE & REFUSE PROPERLY DISPOSED; FACILITIES MAINTAINED
5-501.15 OBSERVED OUTSIDE DUMPSTER OVERFLOWING WITH CARDBOARD BOXES AND OUTSIDE DUMPSTER LID NOT TIGHT FITTING. INSTRUCTED TO NEVER ALLOW THE OUTSIDE DUMPSTER TO OVERFLOW AND ALWAYS MAINTAIN LIDS TIGHT FITTING.
-
Severity not stated
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
6-501.12 OBSERVED A DEAD LARGE ROACH IN THE HALLWAY LEADING OUT OF THE DINING AREA. INSTRUCTED TO REMOVE ALL DEAD INSECTS, CLEAN AND SANITIZED.
-
Serious
Priority
-
Apr 20, 2021 Canvass · Pass — Risk 1 (High)
-
Severity not stated
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
OBSERVED THE HAND WASHING SINK IN THE KITCHEN STAFF WOMENS TOILET ROOM SLOW DRAINING. INSTRUCTED TO REPAIR AND MAINTAIN
-
Severity not stated
-
May 20, 2020 Canvass · Pass — Risk 1 (High)
Result: Pass.
-
Mar 25, 2019 Canvass · Pass — Risk 1 (High)
-
Severity not stated
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED
OBSERVED RUSTY STORAGE SHELVES IN THE DRY STORAGE AREA, INSTRUCTED TO REMOVE THE RUST.
-
Severity not stated
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED
OBSERVED THE #10 CAN OPENER NOT CLEAN IN THE CULINARY KITCHEN 3RD. FL., INSTRUCTED TO CLEAN AND SANITIZE/MAINTAIN.
-
Severity not stated
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
OBSERVED THE KITCHEN REAR DISH, AND FRONT PREP AREAS, LIGHT SHIELDS NOT CLEAN AND DUSTY, INSTRUCTED TO CLEAN AND MAINTAIN. ALSO REMOVE DUST FROM CEILING TILES IN SAME AREAS.
-
Severity not stated
-
Mar 9, 2018 Canvass · Pass — Risk 1 (High)
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
REPAIR/RE-SEAL OR REPLACE LOOSE RUBBER GASKETS AROUND INTERIOR OF 2-DOOR REFRIGERATOR IN CANTEEN AREA.
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
REPAIR DAMAGED, PEELING FLOOR AROUND 3-COMP SINK IN KITCHEN TO MAKE FLOOR SMOOTH AND EASILY CLEANABLE.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
REPAIR LEAK AT FAUCET OF 3-COMP SINK IN KITCHEN AREA.
-
Not serious
Minor
PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
REMOVE CLUTTER AND UNUSED EQUIPMENT IN OLD DISH ROOM NOW USED FOR STORAGE TO PREVENT RODENT HARBORAGE. ORGANIZE AND MAINTAIN AT ALL TIMES.
-
Not serious
Minor
-
Apr 17, 2017 Canvass Re-Inspection · Pass — Risk 1 (High)
Result: Pass.
-
Apr 6, 2017 Canvass Re-Inspection · Fail — Risk 1 (High)
-
Serious
Critical
PREVIOUS SERIOUS VIOLATION CORRECTED, 7-42-090
PREVIOUS SERIOUS VIOLATION FROM REPORT #2009308 ON 3/27/17 NOT CORRECTED: 26 - NO HOT WATER WAS PROVIDED TO THE HANDWASHING SINKS ON THE WEST BUILDING WEST SIDE BOY'S AND GIRL'S WASHROOMS ON THE 2ND FLOOR. MANAGEMENT INSTRUCTED TO PROVIDE TEMPERED WATER ABOVE 85F AT ALL OF THE HANDWASHING SINKS. CRITICAL VIOLATION 7-42-090.
-
Not serious
Serious (Chicago's middle tier)
OUTSIDE GARBAGE WASTE GREASE AND STORAGE AREA; CLEAN, RODENT PROOF, ALL CONTAINERS COVERED
OUTSIDE GARBAGE AREA NOT MAINTAINED CLEAN. OBSERVED EXCESSIVE GARBAGE AND LITTER ON THE GROUND SURROUNDING THE GARBAGE COMPACTOR. MANAGEMENT INSTRUCTED TO CLEAN AND MAINTAIN THE OUTSIDE GARBAGE AREA. SERIOUS VIOLATION 7-38-020.
-
Serious
Critical
-
Mar 27, 2017 Canvass · Fail — Risk 1 (High)
-
Not serious
Serious (Chicago's middle tier)
ADEQUATE NUMBER, CONVENIENT, ACCESSIBLE, PROPERLY DESIGNED AND INSTALLED
NO HOT WATER WAS PROVIDED TO THE HANDWASHING SINKS ON THE WEST BUILDING WEST SIDE BOY'S AND GIRL'S WASHROOMS ON THE 2ND FLOOR. MANAGEMENT INSTRUCTED TO PROVIDE TEMPERED WATER ABOVE 85F AT ALL OF THE HANDWASHING SINKS. SERIOUS VIOLATION 7-38-030.
-
Not serious
Serious (Chicago's middle tier)
-
Mar 18, 2016 Canvass Re-Inspection · Pass — Risk 1 (High)
Result: Pass.
-
Mar 11, 2016 Canvass · Fail — Risk 1 (High)
-
Serious
Critical
WATER SOURCE: SAFE, HOT & COLD UNDER CITY PRESSURE
OBSERVED HOT WATER TEMPERATURES RANGING FROM 48.0F-68.0F AT THE 3 COMPARTMENT SINK FAUCETS, EXPOSED HAND SINKS IN KITCHEN AND WASH BOWLS IN KITCHEN FACULTY WASH ROOMS. INSTRUCTED TO MAINTAIN HOT WATER TEMPERATURES AT 110F AT THE 3 COMPARTMENT SINK FAUCETS AND AT 85F AT ALL HAND WASHING SINKS AT ALL TIMES. ENGINEER AND FACILITIES MANAGER WERE ABLE TO RESTORE THE HOT WATER AT SAID HANDSINKS AND AT 3 COMPARTMENT SINK DURING THE INSPECTION. CRITICAL VIOLATION 7-38-030.
-
Not serious
Serious (Chicago's middle tier)
NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS
OBSERVED EXIT DOOR #3 NOT RODENT PROOFED WITH 1/2 INCH GAP UNDERNEATH SAID EXIT DOOR. INSTRUCTED TO MAKE SAID DOOR RODENT PROOFED AND MAINTAIN. SERIOUS VIOLATION 7-38-020.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
OBSERVED HOT WATER KNOB MISSING ON THE WASHBOWL IN THE MEN'S FACULTY WASHROOM ON THE FIRST FLOOR, ALSO HOT WATER PRESSURE NEEDS TO BE INCREASED AT SAID WASHBOWL AND ON ONE EXPOSED HAND SINK IN THE CULINARY ARTS ROOM ON THE 3RD FLOOR. INSTRUCTED TO REPAIR ALL AND MAINTAIN.
-
Serious
Critical
-
May 28, 2015 Canvass Re-Inspection · Pass — Risk 1 (High)
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
CLEAN FLOORS IN FIRE PUMP ROOM AND SECOND FLOOR MECHANICAL ROOM(DEAD INSECTS.
-
Not serious
Minor
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
PROVIDE LIGHT SHIELDS OR SHATTERPROOF BULBS IN WALK-IN COOLER AND FREEZER.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
REPAIR LEAKING DRAINPIPE UNDER 3-COMPARTMENT SINK. REPAIR TIMED FAUCETS ON SINKS IN ALL WASHROOMS (WATER MUST RUN CONTINUOUSLY FOR AT LEAST 15 SECONDS WITHOUT RETOUCHING HANDLE).
-
Not serious
Minor
-
May 15, 2015 Canvass · Fail — Risk 1 (High)
-
Not serious
Serious (Chicago's middle tier)
FOOD PROTECTED DURING STORAGE, PREPARATION, DISPLAY, SERVICE AND TRANSPORTATION
OBSERVED RED AND BLACK SLIMY MOLD-LIKE SUBSTANCE ON INTERIOR PANEL OF ICE MACHINE. INSTRUCTED MANAGER TO DISCARD ICE, CLEAN, AND SANITIZE ICE MACHINE. SERIOUS VIOLATION 7-38-005A
-
Not serious
Serious (Chicago's middle tier)
NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS
OBSERVED 30-40 MICE DROPPINGS INSIDE CABINETS UNDER COLD HOLDING UNIT IN SERVING AREA, 15-20 MICE DROPPINGS ON FLOOR IN CORNER, 10-15 MICE DROPPINGS ON BOTTOM LEDGE OF ROLLING CARTS IN DRY STORAGE AREA, 20-30 MICE DROPPINGS ON FLOOR ALONG WALLS AND CORNERS IN ELECTRICAL CLOSET NEAR LUNCHROOM. INSTRUCTED MANAGER TO CALL AN EXTERMINATOR FOR SERVICE, CLEAN AND SANITIZE ALL AREAS. DOOR #3 IN AUTO SHOP NOT RODENT PROOFED. 1/4" GAP ON BOTTOM OF DOOR. SEAL ALL OUTER OPENINGS ON DOOR TO PREVENT PEST ENTRY. SERIOUS VIOLATION 7-38-020
-
Not serious
Serious (Chicago's middle tier)
ADEQUATE NUMBER, CONVENIENT, ACCESSIBLE, PROPERLY DESIGNED AND INSTALLED
OBSERVED NO HOT OR TEMPERED WATER AT HAND SINKS IN GIRLS FIRST FLOOR WASHROOM NEAR MAIN ENTRANCE, FIRST FLOOR WOMEN FACULTY WASHROOM, FIRST FLOOR MEN, WOMEN, GIRLS, AND BOYS WASHROOMS NEAR STAGE, SECOND FLOOR WOMEN FACULTY AND GIRLS WASHROOM, THIRD FLOOR GIRLS WASHROOM, HAND SINKS IN CULINARY ARTS. INSTRUCTED MANAGER TO PROVIDE HOT OR TEMPERED WATER AT HAND SINKS FOR PROPER HAND WASHING. SERIOUS VIOLATION 7-38-030
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
REMOVE MILK CRATES AND PROVIDE ADEQUATE SHELVING IN WALK-IN FREEZER AND DRY STORAGE AREA.
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
CLEAN FLOORS IN FIRE PUMP ROOM AND SECOND FLOOR MECHANICAL ROOM(DEAD INSECTS).
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
REPLACE STAINED CEILING TILES IN CANTEEN. SEAL OPENINGS AROUND PIPE FITTINGS IN THIRD FLOOR MEN FACULTY WASHROOM.
-
Not serious
Minor
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
PROVIDE LIGHT SHIELDS OR SHATTERPROOF BULBS IN WALK-IN COOLER AND FREEZER.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
REPAIR LEAKING DRAINPIPE UNDER 3-COMPARTMENT SINK. INCREASE PRESSURE AT LEFT SINK IN GIRLS THIRD FLOOR WASHROOM.
-
Not serious
Serious (Chicago's middle tier)
-
Apr 14, 2014 Canvass Re-Inspection · Pass — Risk 1 (High)
Result: Pass.
-
Apr 7, 2014 Canvass · Fail — Risk 1 (High)
-
Not serious
Serious (Chicago's middle tier)
NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS
FOUND APPROXIMATELY 20 MICE DROPPINGS IN THE KITCHEN MOP CLOSET. ALSO FOUND OVER 40 SMALL FLIES IN KITCHEN MOP CLOSET. INSTRUCTED TO REMOVE ALL PESTS AND DROPPINGS, CLEAN, AND SANITIZE AREA AND MAINTAIN. SERIOUS VIOLATION 7-38-020. CITATION ISSUED.
-
Not serious
Minor
TOILET ROOM DOORS SELF CLOSING: DRESSING ROOMS WITH LOCKERS PROVIDED: COMPLETE SEPARATION FROM LIVING/SLEEPING QUARTERS
FOUND NO SELF CLOSING DEVICE ON WOMEN'S RESTROOM IN THE KITCHEN. INSTRUCTED TO INSTALL A DEVICE AND MAINTIAN.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
FOUND THE COLD WATER HANDLE ON KITCHEN MOP SINK WITH A LEAK. INSTRUCTED TO REPAIR AND MAINTAIN.
-
Not serious
Serious (Chicago's middle tier)
-
Mar 21, 2013 Canvass · Pass — Risk 1 (High)
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
RUBBER GASKETS LOOSE AT TWO OF THE THREE DOORS OF THE THREE DOOR REFRIGERATOR IN KITCHEN; REPAIR OR REPLACE GASKETS.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
REPAIR LEAK FROM PIPE AND THIRD COMPARTMENT OF THREE COMP SINK IN KITCHEN. SINK LEAKING FROM BOTTOM OF THIRD COMPARTMENT. A WORK ORDER HAS BEEN PUT IN FOR SINK PER ENGINEER.
-
Not serious
Minor
Source: Chicago Department of Public Health. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.