Chase Elemen./chase Br
2021 N Point, Chicago, IL 60647 · Cook County
Establishment
- Type
- Food establishment (School)
- Inspected by
- Chicago Department of Public Health
- License / ID
- 22702
- Status
- Risk 1 (High)
- Official record
- Chicago Department of Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 1 | 1 | 0 |
| 2024 | 1 | 1 | 0 |
| 2023 | 2 | 3 | 0 |
| 2022 | 1 | 2 | 0 |
| 2021 | 2 | 3 | 1 |
| 2020 | 1 | 2 | 0 |
| 2019 | 1 | 8 | 0 |
| 2018 | 1 | 0 | 0 |
| 2017 | 1 | 4 | 0 |
| 2016 | 1 | 5 | 0 |
| 2015 | 1 | 4 | 0 |
| 2014 | 2 | 15 | 0 |
| 2013 | 1 | 4 | 0 |
| 2012 | 1 | 2 | 0 |
| 2011 | 1 | 5 | 0 |
| 2010 | 1 | 6 | 0 |
Inspections
-
Feb 4, 2026 Canvass · Pass — Risk 1 (High)
Result: Pass.
-
Feb 4, 2025 Canvass · Pass w/ Conditions — Risk 1 (High)
-
Not serious
Priority Foundation
PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS
FOUND NO VOMIT SPILL KIT AT PREMISES.PRIORITY FOUNDATION.NO CITATION ISSUED.7-38-005.MUST PROVIDE.
-
Not serious
Priority Foundation
-
Feb 8, 2024 Canvass · Pass w/ Conditions — Risk 1 (High)
-
Not serious
Priority Foundation
PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS
FOUND NO VOMIT AND DIARRHEAL CLEANUP PROCEDURE WITH SPILL KIT.PRIORITY FOUNDATION.NO CITATION ISSUED.7-38-005 MUST PROVIDE.
-
Not serious
Priority Foundation
-
Mar 15, 2023 Canvass Re-Inspection · Pass — Risk 1 (High)
Result: Pass.
-
Mar 8, 2023 Canvass · Fail — Risk 1 (High)
-
Severity not stated
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
FOUND CAFETERIA HANDWASH SINK HOT/COLD PUSH BUTTONS AT LESS THAN 15 SECONDS RUNNING WATER TIME WHEN PUSHED. INSTRUCTED TO RECALIBRATE SAID HANDWASH SINK HOT/COLD WATER PUSH BUTTONS TO A MINIMAL 15 SECONDS RUNNING WATER TIME WHEN PUSHED.
-
Severity not stated
INSECTS, RODENTS, & ANIMALS NOT PRESENT
OBSERVED 1/4 INCH GAP AT DOOR SWEEP OF EXIT OUTER DOOR #13. MUST RODENT PROOF SAID DOOR.
-
Not serious
Priority Foundation
GARBAGE & REFUSE PROPERLY DISPOSED; FACILITIES MAINTAINED
OBSERVED 50 RAT DROPPINGS AND EXCESSIVE AMOUNT OF GARBAGE AND LITTER ON THE GROUND SURROUNDING THE GARBAGE DUMPSTERS. MANAGEMENT INSTRUCTED TO CLEAN AND MAINTAIN THE OUTSIDE GARBAGE AREA AT ALL TIMES AND HAVE ALL OUTSIDE GARBAGE DUMPSTER LIDS CLOSED AND TIGHT FITTED. PRIORITY FOUNDATION VIOLATION 7-38-020(B).
-
Severity not stated
-
May 3, 2022 Canvass · Pass w/ Conditions — Risk 1 (High)
-
Not serious
Priority Foundation
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
NO HAND SOAP WAS PROVIDED IN THE WOMEN'S CAFETERIA EMPLOYEE WASHROOM. MANAGEMENT INSTRUCTED TO PROVIDE HAND SOAP AT ALL HAND WASHING SINKS AT ALL TIMES. PRIORITY FOUNDATION VIOLATION 7-38-030(C).
-
Not serious
Priority Foundation
GARBAGE & REFUSE PROPERLY DISPOSED; FACILITIES MAINTAINED
OBSERVED AN EXCESSIVE AMOUNT OF GARBAGE AND LITTER ON THE GROUND SURROUNDING THE GARBAGE DUMPSTERS. MANAGEMENT INSTRUCTED TO CLEAN AND MAINTAIN THE OUTSIDE GARBAGE AREA AT ALL TIMES. PRIORITY FOUNDATION VIOLATION 7-38-020(B).
-
Not serious
Priority Foundation
-
Apr 9, 2021 Canvass Re-Inspection · Pass — Risk 1 (High)
Result: Pass.
-
Apr 7, 2021 Canvass · Fail — Risk 1 (High)
-
Serious
Priority
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
FOUND WATER TEMPERATURE BETWEEN 81.9 F AND 82.6 F AT THE FOLLOWING WASHROOM HANDWASH BOWLS- ROOM #108, INSIDE EMPLOYEES WASHROOM BY TEACHERS LOUNGE AND AT WASHROOMS THROUGHOUT MAIN BUILDING. INSTRUCTED ALL WASHROOMS HANDWASH BOWLS MUST REACH A MINIMAL OF 100.0 F BY DATE OF REINSPECTION. PRIORITY VIOLATION 7-38-030(C).
-
Severity not stated
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
FOUND CAFETERIA EMPLOYEES WASHROOMS HANDWASH BOWLS HOT/COLD PUSH BUTTONS AT LESS THAN 15 SECONDS RUNNING WATER TIME WHEN PUSHED. INSTRUCTED TO RECALIBRATE SAID HANDWASH BOWL HOT/COLD WATER PUSH BUTTONS TO A MINIMAL 15 SECONDS RUNNING WATER TIME WHEN PUSHED.
-
Severity not stated
INSECTS, RODENTS, & ANIMALS NOT PRESENT
OBSERVED 1/4 INCH GAP AT ENTRANCE/EXIT DOOR #13. MUST RODENT PROOF SAID DOOR.
-
Serious
Priority
-
Mar 6, 2020 Canvass · Pass w/ Conditions — Risk 1 (High)
-
Severity not stated
TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED
OBSERVED STAFF WASHROOMS WITHOUT A COVERED WASTE RECEPTACLE. MANAGEMENT INSTRUCTED TO PROVIDE A COVERED WASTE RECEPTACLE INSIDE OF ALL STAFF WASHROOMS.
-
Not serious
Priority Foundation
GARBAGE & REFUSE PROPERLY DISPOSED; FACILITIES MAINTAINED
OBSERVED EXCESSIVE GARBAGE, LITTER AND PET WASTE ON THE GROUND OUTSIDE OF THE GARBAGE DUMPSTERS. MANAGEMENT INSTRUCTED TO MAINTAIN THE AREA CLEAN AT ALL TIMES. PRIORITY FOUNDATION 7-38-020(B). NO CITATION ISSUED.
-
Severity not stated
-
Jan 10, 2019 Canvass · Pass — Risk 1 (High)
-
Not serious
Priority Foundation
ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
OBSERVED NO HAND WASHING SINK ON FRONT SERVING LINE.MUST INSTALL HAND SINK WITH HOT AND COLD RUNNING WATER ON FRONT SERVING LINE.(PRIORITY FOUNDATION-NO CITATION ISSUED)
-
Severity not stated
UTENSILS, EQUIPMENT & LINENS: PROPERLY STORED, DRIED, & HANDLED
MUST INVERT MULTIUSE UTENSILS ON DISH STORAGE SHELVES.
-
Severity not stated
FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED
MUST REPAIR OR REPLACE DAMAGED LOWER EXTERIOR OF WALK IN COOLER DOOR.
-
Severity not stated
NON-FOOD/FOOD CONTACT SURFACES CLEAN
MUST CLEAN DEBRIS FROM INTERIOR OF OVEN.
-
Severity not stated
PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
MUST REPAIR OR REPLACE 2 OF THE 5 FAUCETS IN(G) BASEMENT MAIN BUILDING TOILET ROOM AND 3 OF THE 6 IN (B) 2ND FL. ANNEX BUILDING WATER NOT WORKING AT HAND SINK.
-
Severity not stated
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
MUST REPAIR OR REPLACE STAINED CEILING TILES IN LUNCHROOM AND MISSING & LOOSE WALL BASES AND DAMAGED FLOOR TILES IN PRE-K 010.
-
Severity not stated
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
MUST SCRAPE AND PAINT PEELING PAINT ON WALLS IN LUNCHROOM AND PRE-K 010.
-
Severity not stated
PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
MUST ELEVATE ARTICLES OFF OF FLOOR IN PRE-K 014 CLOSETS.
-
Not serious
Priority Foundation
-
Jan 30, 2018 Canvass · Pass — Risk 1 (High)
Result: Pass.
-
Jan 20, 2017 Canvass · Pass w/ Conditions — Risk 1 (High)
-
Not serious
Serious (Chicago's middle tier)
ADEQUATE NUMBER, CONVENIENT, ACCESSIBLE, PROPERLY DESIGNED AND INSTALLED
OBSERVED NO RUNNING WATER AT ONE OF FOUR HAND WASHING SINKS AT THE GIRLS WASHROOM ON SECOND FLOOR. ENGINEER REPLACED THE BATTERIES AT THE HAND WASHING SINK DURING INSPECTION. SERIOUS VIOLATION 7-38-030.
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
OBSERVED DIRT AND DEBRIS ON FLOOR UNDERNEATH FOOD STORAGE SHELVING IN FRONT SERVING LINE AND REAR STORAGE ROOM. MUST CLEAN AND MAINTAIN.
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
OBSERVED STAINED CEILING TILES IN THE GIRLS WASHROOM ON THE FIRST FLOOR. MUST REPAIR AND MAINTAIN.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
ADDITIONAL WATER PRESSURE NEEDED AT THE 2ND HAND WASHING SINK ON BOYS BATHROOM ON THE LOWER LABEL. MUST REPAIR AND MAINTAIN. OBSERVED DUST ACCUMULATION ON VENTILATION VENT NEAR TO GIRLS WASHROOM IN THE LOWER LABEL. MUST CLEAN AND MAINTAIN.
-
Not serious
Serious (Chicago's middle tier)
-
Jan 15, 2016 Canvass · Pass w/ Conditions — Risk 1 (High)
-
Not serious
Serious (Chicago's middle tier)
ADEQUATE NUMBER, CONVENIENT, ACCESSIBLE, PROPERLY DESIGNED AND INSTALLED
NOTED NO WATER AT ONE OF FOUR HAND WASH SINKS AT THE BOYS BATHROOMS ON FIRST AND SECOND FLOORS. SERIOUS VIOLATION 7-38-030. ENGINEER IMMEDIATELY REPLACED THE BATTERIES AT THE HAND WASH SINKS. INSTRUCTED TO MONITOR AND MAINTAIN.
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
NOTED STAINED CEILING TILES AT THE GIRLS BATHROOM ON THE SECOND FLOOR. INSTRUCTED TO CLEAN AND MAINTAIN.
-
Not serious
Minor
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
NOTED 2 BURNT LIGHT BULBS INSIDE THE BOYS BATHROOMS IN THE FIRST AND SECOND FLOOR. INSTRUCTED TO REPLACE BULBS AND MAINTAIN.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
NOTED LEAKING FAUCET AT THE HAND WASH SINK OF THE EMPLOYEES BATHROOM. INSTRUCTED TO REPAIR AND MAINTAIN.
-
Not serious
Minor
PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
NOTED CLUTTER INSIDE EXTERIOR KITCHEN DRY STORAGE ROOM (HALL WAY). INSTRUCTED TO CLEAN, ORGANIZE AND/OR REMOVE ALL UNNECESSARY ARTICLES TO PREVENT HIDING PLACES FOR PEST.
-
Not serious
Serious (Chicago's middle tier)
-
Jan 20, 2015 Canvass · Pass — Risk 1 (High)
-
Not serious
Minor
CLEAN MULTI-USE UTENSILS AND SINGLE SERVICE ARTICLES PROPERLY STORED: NO REUSE OF SINGLE SERVICE ARTICLES
OBSERVED KNIVES STORED ON SHELVING ABOVE 3-COMPARTMENT SINK IN MAIN KITCHEN. MUST PROPERLY STORE KNIVES IN A KNIFE RACK TO PREVENT CONTAMINATION.
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
MUST CLEAN THE FLOORS IN ALL THE UTILITY/MOP SINK ROOMS THROUGHOUT ANNIX AND MAIN BUILDING. DETAIL CLEAN FLOOR INSIDE BOILER ROOM. REMOVE DIRT AND TRASH.
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
OBSERVED WATER DAMAGE CEILING TILES IN 1ST AND 2ND FLOOR GIRLS AND BOYS BATHROOMS. MUST REPAIR/MAINTAIN.
-
Not serious
Minor
FOOD (ICE) DISPENSING UTENSILS, WASH CLOTHS PROPERLY STORED
OBSERVED WIPING CLOTHES STORED ON TOP OF PREP TABLES IN MAIN KITCHEN. MUST PROPERLY STORE WIPING CLOTHES IN A SANITIZING SOLUTION WHEN NOT IN USE.
-
Not serious
Minor
-
Apr 10, 2014 Canvass Re-Inspection · Pass — Risk 1 (High)
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
Above violation still remaining (Cutting boards that had deep cuts, shall be replaced, cooler shelving/racks that had peeling paint/rust, shall be repaired/replaced. Storage shelving that had exposed raw wood in storage rooms, shall be repaired/sealed).
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
Above violation still remaining( Floors in 3rd floor, 2nd floor boy's bathrooms not clean, need detailed cleaning(corners), floors in storage rooms under shelving/racks not clean, need detailed cleaning(corners). Staircases in old building 1st floor, 2nd floor, and 3rd floor are in state of disrepair(missing stair edges, pieces), shall be repaired/replaced).
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
Above violation still remaining(Walls, ceilings that had peeling paint/plaster in staircase(new building), shall be repaired/sealed. Walls ceilings that had had peeling paint in classrooms # 303, # 302,(old building) and staircases in old, and new building shall be repaired/sealed. Damaged/missing ceiling tiles in classrooms, storage rooms(2ND floor, 3RD floor)in new building, shall be repaired/replaced).
-
Not serious
Minor
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
Above violation still remaining(Broken, damaged and missing light shields in boys bathroom, storage room, classrooms in new building, shall be provided).
-
Not serious
Minor
TOILET ROOM DOORS SELF CLOSING: DRESSING ROOMS WITH LOCKERS PROVIDED: COMPLETE SEPARATION FROM LIVING/SLEEPING QUARTERS
Above violation still remaining(Bathroom doors were missing self closing mechanism for the following bathrooms, staff bathrooms, employee bathrooms, and the unisex bathrooms, shall provide self closing mechanism to the above bathrooms).
-
Not serious
Minor
PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
Above violation still remaining( Stock items must be kept six inches off of floor to prevent pest harborage).
-
Not serious
Minor
-
Apr 3, 2014 Canvass · Fail — Risk 1 (High)
-
Not serious
Serious (Chicago's middle tier)
OUTSIDE GARBAGE WASTE GREASE AND STORAGE AREA; CLEAN, RODENT PROOF, ALL CONTAINERS COVERED
Above had outside garbage/dumpsters, 3 dumpsters overflowing, lids open, not able to closed.Serious citation issued 7-38-020.
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
Cutting boards that had deep cuts, shall be replaced, cooler shelving/racks that had peeling paint/rust, shall be repaired/replaced. Storage shelving that had exposed raw wood in storage rooms, shall be repaired/sealed.
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
Non food contact surfaces of walk in cooler shelving/racks not clean, need detailed cleaning(crevices). Cooler shelving/racks in kitchen prep area, lunchroom not clean, need detailed cleaning(crevices).
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
Floors in kitchen prep area behind heavy equipment not clean, need detailed cleaning(corners), floors in 3rd floor, 2nd floor boy's bathrooms not clean, need detailed cleaning(corners), floors in storage rooms under shelving/racks not clean, need detailed cleaning(corners). Staircases in old building 1st floor, 2nd floor, and 3rd floor are in state of disrepair(missing stair edges, pieces), shall be repaired/replaced.
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
Walls, ceilings that had peeling paint/plaster in staircase(new building), shall be repaired/sealed.Ceiling tiles in kitchen prep area not clean, need cleaning. Walls ceilings that had had peeling paint in classrooms # 303, # 302,(old bulding) and staircases in old, and new building shall be repaired/sealed. Damaged/missing ceiling tiles in classrooms, storage rooms(2nd floor, 3rd floor)in new building, shall be repaired/replaced.
-
Not serious
Minor
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
Broken, damaged and missing light shields in boys bathroom, storage room, classrooms in new building, shall be provided.
-
Not serious
Minor
TOILET ROOM DOORS SELF CLOSING: DRESSING ROOMS WITH LOCKERS PROVIDED: COMPLETE SEPARATION FROM LIVING/SLEEPING QUARTERS
Bathroom doors were missing self closing mechanism for the following bathrooms, staff bathrooms, employee bathrooms, and the unisex bathrooms, shall provide self closing mechanism to the above bathrooms.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
Exhaust vents(ventilation) in walk in cooler, coolers not clean, need cleaning(detailed), exhaust vents(ventilation) in all bathrooms not clean, need detailed cleaning.
-
Not serious
Minor
PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
Stock items must be kept six inches off of floor to prevent pest harborage.
-
Not serious
Serious (Chicago's middle tier)
-
Apr 25, 2013 Canvass · Pass — Risk 1 (High)
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
THE FOLLOWING NEEDS CLEANING: FILTERS ON HOOD IN KITCHEN, VENT IN DINING, INSIDE TOP WALLS OF MICROWAVE OVENS IN TEACHERS LOUNGE, CABINET DRAWERS IN TEACHER LUNCH ROOM.
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
MUST CLEAN THE FLOORS IN ALL THE UTILITY/MOP SINK ROOMS THROUGHOUT ANNIX AND MAIN BUILDING.
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
CLEAN THE VENTS IN THE KITCHEN AND IN THE LUNCHROOM HAS DUST BUILDUP ON THEM.
-
Not serious
Minor
PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
MAIN BUILDING ROOM 116 PRE K CLOSET HAS ABOUT 10 BOXES OF OLD EMPLOYEE RECORDS, BASEMENT MAINTENANCE ROOM BUY THE BOYS TOILET ROOM HAS 50 BOXES OF OLD EMPLOYEES RECORDS ,OLD UNUSED EQUIPMENT NEED TO REMOVE SO NO INSECT OR RODENT HARBORAGE. ANNEX SECOND FLOOR MOST CLASSROOMS HAVE CULTTER COVERING AND ON TOP OF THE HEATING, COOLING AND AIR FLOW UNIVENTS. MUST REMOVE THE CLUTTER AWAY FROM ALL THE UNIVENTS TO GET BETTER AIRFLOW.
-
Not serious
Minor
-
May 7, 2012 Canvass · Pass — Risk 1 (High)
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
MUST CLEAN WALL BY DISH MACHINE ARE, REMOVE ALL MOLDY LOOKING SEALANT FROM WALL
-
Not serious
Minor
LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
MUST PROVIDE LIGHT SHIELD IN WALK-IN COOLER KITCHEN AREA
-
Not serious
Minor
-
Mar 2, 2011 Canvass · Pass — Risk 1 (High)
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair.CLEAN and maintain the floors and baseboards so they are smooth and sanitary from corner to corner.
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
The walls and ceilings shall be in good repair and easily cleaned.FOUND SCATTERED SITES OF PEELING PAINT ON WALLS IN VARIOUS AREAS OF KITCHEN AREAS,DISHROOM-MUST REPAIR TO SMOOTH,EASILY CLEANABLE SURFACE
-
Not serious
Minor
VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
Ventilation: All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health.FOUND FAUCET SENSOR AT HANDSINK POOR REPAIR IN TOILET ROOM LOCATION PREK CLASSROM#014-MUST REPAIR.
-
Not serious
Minor
PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
All parts of the food establishment and all parts of the property used in connection with the operation of the establishment shall be kept neat and clean and should not produce any offensive odors.MUST CLEAN,ORGANIZE ALL STORAGE CLOSETS,UTILITY SINK CLOSETS,PRE-K CLASSROOM #014- REMOVE CLUTTER DUE TO POTENTIAL PEST HARBORAGE.
-
Not serious
Minor
APPROPRIATE METHOD OF HANDLING OF FOOD (ICE) HAIR RESTRAINTS AND CLEAN APPAREL WORN
All employees shall be required to use effective hair restraints to confine hair.PREK CLASSROOM Food handlers must have hair restraints when working around open food.
-
Not serious
Minor
-
Feb 3, 2010 Canvass · Pass — Risk 1 (High)
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair. MUST REPAIR RUSTED WALK-IN COOLER FLOORS IN KITCHEN,AND REPAIR DAMAGED CABINET DOOR UNDER HAND WASH SINK IN PRE-K CLASSROOM #402.
-
Not serious
Minor
FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
All utensils shall be thoroughly cleaned and sanitized after each usage. All food and non-food contact surfaces of equipment and all food storage utensils shall be thoroughly cleaned and sanitized daily. OUTER WALLS OF DISH WASHING MACHINE NEEDS CLEANING. ALSO VENT IN PRE-K CLASSROOM #404 NEEDS CLEANING.
-
Not serious
Minor
FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair. FLOORS UNDER SHELVES IN CLOSET BY BOYS TOILET IN BASEMENT NEEDS CLEANING.
-
Not serious
Minor
WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
The walls and ceilings shall be in good repair and easily cleaned. OPENING ON WALL AT SOUTH CORNER ENTRANCE TO BOILER ROOM NEEDS TO BE SEALED.
-
Not serious
Minor
REFRIGERATION AND METAL STEM THERMOMETERS PROVIDED AND CONSPICUOUS
All food establishments that display, prepare, or store potentially hazardous foods shall have calibrated metal stem thermometers, provided and conspicuous, for refrigerated and hot food units. MUST PROVIDE METAL STEM THERMOMETER INSIDE COOLERS IN ALL PRE-K CLASSROOMS, AND IN THE TEACHER'S LOUNGE COOLERS .
-
Not serious
Minor
PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
Cleaning equipment shall be properly stored away from food, utensils, equipment, and clean linens. All parts of the food establishment and all parts of the property used in connection with the operation of the establishment shall be kept neat and clean and should not produce any offensive odors. MUST ORGANIZE AND OR REMOVE EXCESSIVE CLUTTER IN PRE-K COAT STORAGE CLOSETS IN CLASSROOMS #404& 403.
-
Not serious
Minor
Source: Chicago Department of Public Health. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.