RecordWell Data

Nixon Annex

4150 W DICKENS, Chicago, IL 60639 · Cook County

26cited violations
2serious tier
19inspections
4tier not stated

Establishment

Type
Food establishment (School)
Inspected by
Chicago Department of Public Health
License / ID
24682
Status
Risk 1 (High)
Official record
Chicago Department of Public Health inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026100
2025210
2024100
2023100
2022110
2021110
2020230
2019120
2018220
2017140
2016150
2015222
2014130
2013220

Inspections

  1. Feb 23, 2026 Canvass · Pass — Risk 1 (High)

    Result: Pass.

  2. Feb 14, 2025 Canvass Re-Inspection · Pass — Risk 1 (High)

    Result: Pass.

  3. Feb 4, 2025 Canvass · Fail — Risk 1 (High)
    • Not serious Priority Foundation

      GARBAGE & REFUSE PROPERLY DISPOSED; FACILITIES MAINTAINED

      OBSERVED OUTSIDE GARBAGE DUMPSTER LID MISSING. MUST REPLACE LIDS TO BE TIGHT FITTING. (PRIORITY FOUNDATION 7-38-020(B)(NO CITATION ISSUED)

  4. Feb 1, 2024 Canvass · Pass — Risk 1 (High)

    Result: Pass.

  5. Jan 12, 2023 Canvass · Pass — Risk 1 (High)

    Result: Pass.

  6. May 6, 2022 Canvass · Pass — Risk 1 (High)
    • Severity not stated

      PLUMBING INSTALLED; PROPER BACKFLOW DEVICES

      OBSERVED BOTH FAUCETS ON THE THREE COMPARTMENT SINK LEAKING. FOUND LOW HOT WATER PRESSURE AT THE 2ND FLOOR BOYS WASHROOM RIGHT HANDWASH SINK AND THE 2ND FLOOR GIRLS WASHROOM LEFT HANDWASH SINK. INSTRUCTED MANAGEMENT TO REPAIR ALL SINKS AND MAINTAIN.

  7. May 6, 2021 Canvass · Pass — Risk 1 (High)
    • Severity not stated

      PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN

      OBSERVED DUST BUILD UP INSIDE LIGHT SHIELDS IN EMPLOYEE WASHROOM. MUST CLEAN AND MAINTAIN.

  8. Sep 18, 2020 Canvass Re-Inspection · Pass — Risk 1 (High)

    Result: Pass.

  9. Sep 11, 2020 Canvass · Fail — Risk 1 (High)
    • Not serious Priority Foundation

      PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS

      OBSERVED NO VOMIT AND DIARRHEA CLEAN UP KIT/PROCEDURE ON SITE. MUST PROVIDE WRITTEN PROCEDURE FOR THE CLEAN UP OF VOMIT AND DIARRHEAL EVENTS, AND CORRESPONDING EQUIPMENT OUTLINE IN PROCEDURE. MUST HAVE A SANITIZER EFFECTIVE AGAINST NOROVIRUS. PRIORITY FOUNDATION VIOLATION 7-38-005. NO CITATION ISSUED.

    • Severity not stated

      ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED

      OBSERVED EXCESSIVE DUST ACCUMULATION ON CEILING VENTILATION COVER IN EMPLOYEE RESTROOM. MUST DETAIL CLEAN. MUST MAINTAIN SAME.

    • Not serious Priority Foundation

      PREVIOUS CORE VIOLATION CORRECTED

      OBSERVED PREVIOUSLY ISSUED CORE VIOLATION NOT CORRECTED FROM REPORT # 2285689 DATED 4/24/19. MUST CORRECT VIOLATION # 53: NO COVERED WASTE RECEPTACLE WAS PROVIDED IN THE KITCHEN STAFF WASHROOM. MUST PROVIDE. PRIORITY FOUNDATION VIOLATION 7-42-090. NO CITATION ISSUED.

  10. Apr 24, 2019 Canvass · Pass w/ Conditions — Risk 1 (High)
    • Not serious Priority Foundation

      PROCEDURES FOR RESPONDING TO VOMITING AND DIARRHEAL EVENTS

      OBSERVED NO SANITIZER EFFECTIVE AGAINST NOROVIRUS ON THE PREMISES AS PART OF THE WRITTEN VOMIT AND DIARRHEA CLEAN UP PROCEDURE. MANAGEMENT INSTRUCTED TO PROVIDE A COMPLETE SUPPLY KIT AS POSTED. PRIORITY FOUNDATION 7-38-005. NO CITATION ISSUED.

    • Severity not stated

      TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED

      NO COVERED WASTE RECEPTACLE WAS PROVIDED IN THE KITCHEN STAFF WASHROOM. MUST PROVIDE.

  11. Jan 26, 2018 Canvass Re-Inspection · Pass — Risk 1 (High)

    Result: Pass.

  12. Jan 19, 2018 Canvass · Fail — Risk 1 (High)
    • Not serious Serious (Chicago's middle tier)

      OUTSIDE GARBAGE WASTE GREASE AND STORAGE AREA; CLEAN, RODENT PROOF, ALL CONTAINERS COVERED

      OUTSIDE GARBAGE AREA NOT MAINTAINED AND DUMPSTER CONTAINERS NOT COVERED. INSTRUCTED MANAGER TO CLEAN OUTSIDE GARBAGE AREA AND MAINTAIN DUMPSTER CONTAINERS TO BE RODENT PROOF. SERIOUS VIOLATION: 7-38-020 (NO CITATION ISSUED)

    • Not serious Minor

      FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED

      OBSERVED DAMAGED/PEELING PAINT FLOOR UNDER THE 3-COMPARTMENT SINK AND UNDER THE DRYING RACK IN FOOD PREP AREA. INSTRUCTED TO REPAIR/REPAINT AND MAINTAIN.

  13. Jan 31, 2017 Canvass · Pass — Risk 1 (High)
    • Not serious Minor

      FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED

      MUST REMOVE RUST FROM WALK IN COOLER #2 SHELVING UNITS.

    • Not serious Minor

      FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS

      MUST CLEAN FOOD DEBRI FROM WALK IN COOLER #1 SHELVING UNITS AND PRE K 115 & 117.

    • Not serious Minor

      FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED

      MUST CLEAN DEBRI FROM FLOORS IN WALK IN FREEZER & WALK IN COOLER #1,PRE-K 115 & 117.MUST REMOVE RUST FROM FLOOR IN WALK IN COOLER #2.MUST SCRAPE AND PAINT PEELING PAINT ON FLOOR IN KITCHEN MAKE SMOOTH AND EASILY CLEANABLE.

    • Not serious Minor

      WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS

      MUST CLEAN DEBRI FROM LIGHT SHIELD IN OFFICE/DRY FOOD STORAGE AREA.

  14. Mar 2, 2016 Canvass · Pass — Risk 1 (High)
    • Not serious Minor

      FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED

      OBSERVED RUSTY COOLER STORAGE RACKS,INSTRUCTED TO REMOVE THE RUST.

    • Not serious Minor

      FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED

      OBSERVED THE BOYS RESTROOM FLOOR NOT CLEAN(URINE SMELL), INSTRUCTED TO CLEAN AND SANITIZE.ALSO REPLACE BROKEN FLOOR TILES IN HEADSTSTART ROOM 115/116.

    • Not serious Minor

      WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS

      OBSERVED CEILING VENTS DUSTY, AND LIGHT SHIELDS NOT CLEAN, INSTRUCTED TO CLEAN.

    • Not serious Minor

      LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED

      OBSERVED THE LIGHT OUT OVER THE MOP SINK AREA, INSTRUCTED TO REPLACE.

    • Not serious Minor

      VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED

      OBSERVED THE KITCHEN HAND SINK LEAKING WATER AT NOZZLE, INSTRUCTED TO REPAIR.

  15. May 1, 2015 Canvass Re-Inspection · Pass — Risk 1 (High)

    Result: Pass.

  16. Apr 27, 2015 Canvass · Pass w/ Conditions — Risk 1 (High)
    • Serious Critical

      FACILITIES TO MAINTAIN PROPER TEMPERATURE

      FOUND WALK IN COOLER AT IMPROPER COLD HOLDING TEMPERATURES. 51.2F. TAGGED WALK IN COOLER. CRITICAL VIOLATION. 7-38-005A. INSTRUCTED MANAGEMENT TO NOTIFY FOOD PROTECTION DIVISION WHEN COOLER IS REPAIRED.

    • Serious Critical

      POTENTIALLY HAZARDOUS FOOD MEETS TEMPERATURE REQUIREMENT DURING STORAGE, PREPARATION DISPLAY AND SERVICE

      FOUND POTENTIALLY HAZARDOUS FOOD AT IMPROPER COLD HOLDING TEMPERATURES. FOUND 30 POUNDS OF SLICED HAM AT 46.7F, AND 50 POUNDS CHEESE AT 49.7F. CRITICAL VIOLATION. NO CITATION ISSUED. DIPOSED OF 80 POUNDS OF POTENTIALLY HAZARDOUS FOOD. VALUE AT 100 DOLLARS.

  17. Apr 28, 2014 Canvass · Pass — Risk 1 (High)
    • Not serious Minor

      FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED

      MUST REMOVE RUST FROM SHELVING UNITS IN MILK WALK IN COOLER & DISHWASHING STORAGE SHELF.

    • Not serious Minor

      FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS

      MUST CLEAN FOOD DEBRI FROM ROLLING CART IN WALK IN COOLER.

    • Not serious Minor

      FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED

      MUST REMOVE RUST FROM FLOOR IN WALK IN COOLER.

  18. Feb 26, 2013 Canvass Re-Inspection · Pass — Risk 1 (High)

    Result: Pass.

  19. Feb 19, 2013 Canvass · Fail — Risk 1 (High)
    • Not serious Serious (Chicago's middle tier)

      NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS

      OBSERVED APPROX. 50 RODENT DROPPINGS IN PRE K CLASS ROOMS 115/116 AND 3RD FLOOR BOILER ROOM, UNDER AND BEHIND EQUIPMENT, IN CORNERS, ON TOYS AND IN CHILDREN'S COAT AREA, INSTRUCTED TO THOROUGHLY CLEAN ALL AREAS, SERIOUS CITATION ISSUED:7-38-020

    • Not serious Minor

      PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED

      INSTRUCTED TO CLEAN AND BETTER MAINTAIN, PRE K CLASS ROOMS, MUST REMOVE ALL CLUTTER, MUST CLEAN BOYS BATHROOMS, REMOVE SMELLY URINE ODORS

Source: Chicago Department of Public Health. History last read Oct 1, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.