Radisson Hotel & Conference Center-swimming Pool
625 W ROLLING MEADOWS DR, Fond Du Lac, WI 54935 · Fond du Lac County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Fond du Lac County Health Department
- License / ID
- HSAT-7QWUDY
- Status
- Permitted
- Phone
- (920) 923-1440
- Official record
- Fond du Lac County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 1 | 7 | 0 |
| 2023 | 1 | 3 | 0 |
Inspections
-
Sep 10, 2026 Routine · No items found
No violations cited.
-
Aug 11, 2025 Routine · 7 non-critical
-
Not serious
Non-critical
SKIMMERS-ADJUSTED
All 4 skimmers not adjusted to ensure vigorous skimming.
Correction: Adjust all 4 skimmers to maintain vigorous skimming .
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. At the maximum flowmeter rate of 110 gpm, the turnover rate cannot be accurately calculated due to an inadequate flowmeter. With the maximum reading on the flowmeter, the turnover rate is 7.57 hours which exceeds the code requirement amount.
Correction: Replace the flowmeter to accurately read the actual flow rate and to properly calculate the turnover rate.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
In talking with the Maintenance Supervisor during the inspetions, the establishment indicated that they are using the "Monthly Pump Safety Check" column on their monthly test log to indicate successful checks of their pool equipment and not to indicate chemical interlock testing. The establishment does not have a log to document the testing of their chemical interlock system.
Correction: Education provided to the establishment to correctly use the "Monthly Pump Safety Check" column to indicate successful testing of their chemical interlock system. Also provided the establishment with the most current DATCP monthly pool testing log. Going forward, use the "Monthly Pump Safety Check" column to indicate successful testing of the chemical interlock system.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POOL RULES SIGNAGE-SHOWER
Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Code ATCP 76.29(1)(b)1.c. - SHOWER
-
Not serious
Non-critical
POOL RULES SIGNAGE-NO GLASS OR SHATTERABLE
Pool rules missing rule: Glass and shatterable items are prohibited in the pool area.
Correction: Include pool rule on sign: Glass and shatterable items are prohibited in the pool area.
Code ATCP 76.29(1)(b)1.g - NO GLASS OR SHATTERABLE
-
Not serious
Non-critical
Corrected on site
FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS
The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises.
Correction: Provided a copy of the most recent United States centers for disease control and prevention recommendations for fecal accident response recommendations on the premises.
Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES
-
Not serious
Non-critical
-
Apr 25, 2023 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE
The combined chlorine is at 1.64 PPM.
Correction: Treat the pool with breakpoint chlorination using a chlorine product or a nonchlorinated oxidizer.
Code ATCP 76.14(4)(e)
-
Not serious
Non-critical
Repeat
SIGNAGE "NO LIFEGUARD ON DUTY"
A pool basin in the facility does not have a “No Lifeguard on Duty” sign that complies with ATCP 76.22(1)(c).
Correction: Provide a “No Lifeguard on Duty Sign” that complies with ATCP 76.22(1)(c).
Code ATCP 76.22(1)(c)
-
Not serious
Non-critical
Repeat
EQUIPMENT NOT MAINTAINED
Pool pump is not being maintained and repaired as necessary. It is currently leaking water.
Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).
Code ATCP 76.33(1)(e)
-
Not serious
Non-critical
Repeat
Source: Fond du Lac County Health Department. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.