Taylor Park-pool
380 EMMA ST, Fond Du Lac, WI 54936 · Fond du Lac County
Establishment
- Type
- Pool / recreational water (Pool - Complex with Features)
- Inspected by
- Fond du Lac County Health Department
- License / ID
- HSAT-7QWC6F
- Status
- Permitted
- Phone
- (920) 322-3955
- Official record
- Fond du Lac County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 1 | 6 | 3 |
| 2023 | 1 | 1 | 0 |
Inspections
-
Aug 4, 2025 Routine · 3 critical, 3 non-critical
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
WATER HEATERS-MAINTAINED OPERATIONAL
East Water heater or heat exchanger not in operating condition.
Correction: Maintain water heater or heat exchanger in operating condition.
Code ATCP 76.33(4)(a) - MAINTAINED
-
Serious
Critical
OPERATOR KNOWLEDGE-MONTHLY TESTING
The person responsible is not able to describe how monthly testing is performed.
Correction: Ensure that operator can describe how monthly testing is performed.
Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING
-
Serious
Critical
HOSING - BACKFLOW PREVENTION DEVICE
The hose bibb on NE side of the building next to the water fountain is missing a backflow preventor.
Correction: Provide backflow preventors to all hose bibbs.
Code ATCP 76.33(1)(d)2. - BACKFLOW PREVENTION
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve available to review.
Correction: Obtain a pump curve for the main pool on site.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Jun 29, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
EQUIPMENT NOT MAINTAINED
Sand filter 2 is leaking and is not being maintained and repaired as necessary.
Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).
Code ATCP 76.33(1)(e)
-
Not serious
Non-critical
Source: Fond du Lac County Health Department. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.