RecordWell Data

Nova Collective

836 SECURITY DR, Fond Du Lac, WI 54935 · Fond du Lac County

33cited violations
5serious tier
7inspections

Establishment

Type
Pool / recreational water (Pool - Simple)
Inspected by
Fond du Lac County Health Department
License / ID
JBIH-D67TNJ
Status
Permitted
Phone
(920) 312-2702
Official record
Fond du Lac County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026110
20253111
20243214

Inspections

  1. Sep 10, 2026 Routine · 1 non-critical, 1 repeat
    • Not serious Non-critical Repeat

      LICENSE NOT POSTED

      The current license is not posted.

      Correction: Post the current license

      Code ATCP 76.05(7) - LICENSE POSTED

  2. Sep 2, 2025 Follow Up · 3 non-critical, 3 repeat
    • Not serious Non-critical Repeat

      SKIMMERS-ADJUSTED

      Vigorous skimming action was not observed at each skimmer.

      Correction: Adjust skimmers to maintain vigorous skimming .

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical Repeat

      THERMOMETER RETURN LINE

      A thermometer is not located in the pool water return line.

      Correction: Provide a thermometer in the pool water return line.

      Code ATCP 76.19(4)(a)1 - THERMOMETER

    • Not serious Non-critical Repeat

      POOL RULES SIGNAGE-SHOWER

      Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Code ATCP 76.29(1)(b)1.c. - SHOWER

  3. Aug 6, 2025 Routine · 1 critical, 7 non-critical
    • Not serious Non-critical

      LICENSE NOT POSTED

      The license is not posted for public view.

      Correction: Post the license where it can be viewed by the public.

      Code ATCP 76.05(7) - LICENSE POSTED

    • Not serious Non-critical

      SKIMMERS-ADJUSTED

      Vigorous skimming action was not observed at each skimmer.

      Correction: Adjust skimmers to maintain vigorous skimming .

      Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED

    • Not serious Non-critical

      THERMOMETER RETURN LINE

      A thermometer is not located in the pool water return line.

      Correction: Provide a thermometer in the pool water return line.

      Code ATCP 76.19(4)(a)1 - THERMOMETER

    • Not serious Non-critical

      BIOHAZARD KIT ITEMS

      The biohazard kit is present but missing items including the scoop and spatuala, as well as the biohazard sorbent.

      Correction: Replace the missing items in the biohazard kit.

      Code ATCP 76.27(2)(b) - BIOHAZARD KIT ITEMS

    • Not serious Non-critical

      POOL RULES SIGNAGE-SHOWER

      Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.

      Code ATCP 76.29(1)(b)1.c. - SHOWER

    • Not serious Non-critical

      POSTING SIGNAGE-MAX PATRON LOAD

      Maximum patron load is not posted.

      Correction: Post signage indicating Maximum patron load.

      Code ATCP 76.29(1)(e) - MAX PATRON LOAD

    • Not serious Non-critical Corrected on site

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response. I provided this guidance to the opperator during todays inspection.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Serious Critical

      GATES AND DOORS-LATCHING

      The north guest entry gate is not self latching.

      Correction: Provide an immediate temporary fix by Locking this gate and informing guests to use the other functioning gate until the north gate latch is fixed. Permantely fix the north gate to be self latching by August 29th.

      Code ATCP 76.34(4)(a)(1m)(b)- LATCHING

  4. May 12, 2025 Re-inspection · No items found

    No violations cited.

  5. Oct 16, 2024 Pre-inspection Follow Up · 1 critical, 3 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmer floating weirs are missing in the skimmers.

      Correction: Replace skimmer floating weirs.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-GPM

      The VGBA log or other proof does not indicate drain cover gallons per minute rating.

      Correction: Indicate in the log the drain cover gallons per minute rating.

      Code ATCP 76.38(2)(b)3. - COVER GPM RATING

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-LIFESPAN

      The VGBA log or other proof does not indicate main drain cover and equilizer cover life span.

      Correction: Indicate in the log the drain cover life span.

      Code ATCP 76.38(2)(b)4. - LIFESPAN

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the specificatios for the main drains and for the equilizer covers.

      Correction: Obtain a gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  6. Aug 16, 2024 Pre-inspection Follow Up · 1 critical, 5 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmer floating weirs are missing in the skimmers.

      Correction: Replace skimmer floating weirs.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      DOORS

      The garage is also used as a chemical storage area and it is not marked to indicate entry is for authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-GPM

      The VGBA log or other proof does not indicate drain cover gallons per minute rating.

      Correction: Indicate in the log the drain cover gallons per minute rating.

      Code ATCP 76.38(2)(b)3. - COVER GPM RATING

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-LIFESPAN

      The VGBA log or other proof does not indicate main drain cover and equilizer cover life span.

      Correction: Indicate in the log the drain cover life span.

      Code ATCP 76.38(2)(b)4. - LIFESPAN

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the specificatios for the main drains and for the equilizer covers.

      Correction: Obtain a gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  7. Jun 14, 2024 Pre-inspection · 2 critical, 9 non-critical
    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmer Float Valves are missing in the skimmers. There is only one present.

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      DOORS

      Chemical storage areas are not locked and marked to indicate entry is for authorized personnel only.

      Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.

      Code ATCP 76.12 (2)(i) - DOORS

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did have an interolock testing operating plan in place.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023

      A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:

      Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.

      Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS

    • Not serious Non-critical

      POOL CLOSED SIGN

      No 'closed' sign available.

      Correction: Provide a sign that indicates the pool area is closed.

      Code ATCP 76.34(5) - 'CLOSED' SIGN

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-GPM

      The VGBA log or other proof does not indicate drain cover gallons per minute rating.

      Correction: Indicate in the log the drain cover gallons per minute rating.

      Code ATCP 76.38(2)(b)3. - COVER GPM RATING

    • Not serious Non-critical

      VGBA DRAIN COVER INFO-LIFESPAN

      The VGBA log or other proof does not indicate drain cover life span.

      Correction: Indicate in the log the drain cover life span.

      Code ATCP 76.38(2)(b)4. - LIFESPAN

    • Serious Critical

      GATES AND DOORS MECHANISM 54 INCHES

      A self-closing latching and lockable mechanism is not present on the North gate.

      Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.

      Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

Source: Fond du Lac County Health Department. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.