Nova Collective
836 SECURITY DR, Fond Du Lac, WI 54935 · Fond du Lac County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Fond du Lac County Health Department
- License / ID
- JBIH-D67TNJ
- Status
- Permitted
- Phone
- (920) 312-2702
- Official record
- Fond du Lac County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 0 |
| 2025 | 3 | 11 | 1 |
| 2024 | 3 | 21 | 4 |
Inspections
-
Sep 10, 2026 Routine · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
LICENSE NOT POSTED
The current license is not posted.
Correction: Post the current license
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
Repeat
-
Sep 2, 2025 Follow Up · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
SKIMMERS-ADJUSTED
Vigorous skimming action was not observed at each skimmer.
Correction: Adjust skimmers to maintain vigorous skimming .
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
Repeat
THERMOMETER RETURN LINE
A thermometer is not located in the pool water return line.
Correction: Provide a thermometer in the pool water return line.
Code ATCP 76.19(4)(a)1 - THERMOMETER
-
Not serious
Non-critical
Repeat
POOL RULES SIGNAGE-SHOWER
Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Code ATCP 76.29(1)(b)1.c. - SHOWER
-
Not serious
Non-critical
Repeat
-
Aug 6, 2025 Routine · 1 critical, 7 non-critical
-
Not serious
Non-critical
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
SKIMMERS-ADJUSTED
Vigorous skimming action was not observed at each skimmer.
Correction: Adjust skimmers to maintain vigorous skimming .
Code ATCP 76.11(2)(a) 1. - SKIMMERS ADJUSTED
-
Not serious
Non-critical
THERMOMETER RETURN LINE
A thermometer is not located in the pool water return line.
Correction: Provide a thermometer in the pool water return line.
Code ATCP 76.19(4)(a)1 - THERMOMETER
-
Not serious
Non-critical
BIOHAZARD KIT ITEMS
The biohazard kit is present but missing items including the scoop and spatuala, as well as the biohazard sorbent.
Correction: Replace the missing items in the biohazard kit.
Code ATCP 76.27(2)(b) - BIOHAZARD KIT ITEMS
-
Not serious
Non-critical
POOL RULES SIGNAGE-SHOWER
Pool rules missing rule: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Correction: Include pool rule on sign: Shower immediately before entering the pool and after use of a steam room, sauna, or toilet facilities.
Code ATCP 76.29(1)(b)1.c. - SHOWER
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
Corrected on site
FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS
The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:
Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response. I provided this guidance to the opperator during todays inspection.
Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES
-
Serious
Critical
GATES AND DOORS-LATCHING
The north guest entry gate is not self latching.
Correction: Provide an immediate temporary fix by Locking this gate and informing guests to use the other functioning gate until the north gate latch is fixed. Permantely fix the north gate to be self latching by August 29th.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
-
May 12, 2025 Re-inspection · No items found
No violations cited.
-
Oct 16, 2024 Pre-inspection Follow Up · 1 critical, 3 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer floating weirs are missing in the skimmers.
Correction: Replace skimmer floating weirs.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-GPM
The VGBA log or other proof does not indicate drain cover gallons per minute rating.
Correction: Indicate in the log the drain cover gallons per minute rating.
Code ATCP 76.38(2)(b)3. - COVER GPM RATING
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA log or other proof does not indicate main drain cover and equilizer cover life span.
Correction: Indicate in the log the drain cover life span.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the specificatios for the main drains and for the equilizer covers.
Correction: Obtain a gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Aug 16, 2024 Pre-inspection Follow Up · 1 critical, 5 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer floating weirs are missing in the skimmers.
Correction: Replace skimmer floating weirs.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
DOORS
The garage is also used as a chemical storage area and it is not marked to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-GPM
The VGBA log or other proof does not indicate drain cover gallons per minute rating.
Correction: Indicate in the log the drain cover gallons per minute rating.
Code ATCP 76.38(2)(b)3. - COVER GPM RATING
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA log or other proof does not indicate main drain cover and equilizer cover life span.
Correction: Indicate in the log the drain cover life span.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the specificatios for the main drains and for the equilizer covers.
Correction: Obtain a gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
-
Jun 14, 2024 Pre-inspection · 2 critical, 9 non-critical
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmer Float Valves are missing in the skimmers. There is only one present.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
DOORS
Chemical storage areas are not locked and marked to indicate entry is for authorized personnel only.
Correction: Lock doors to chemical storage areas and mark to indicate entry is for authorized personnel only.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did have an interolock testing operating plan in place.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-DSPS CONTRUCTION PLANS FOR POOL BUILT AFTER JULY 1, 2023
A copy of the Wisconsin pool constructions plans, including Virginia Graeme Baker Act plan approvals, was not permanently maintained on premises:
Correction: For pools constructed after July 1, 2023, maintain a copy of the pool construction plans, including Virginia Graeme Baker Act plan approvals, on premises permanently.
Code ATCP 76.32(3)(a)2. - COSTRUCTION PLANS
-
Not serious
Non-critical
POOL CLOSED SIGN
No 'closed' sign available.
Correction: Provide a sign that indicates the pool area is closed.
Code ATCP 76.34(5) - 'CLOSED' SIGN
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-GPM
The VGBA log or other proof does not indicate drain cover gallons per minute rating.
Correction: Indicate in the log the drain cover gallons per minute rating.
Code ATCP 76.38(2)(b)3. - COVER GPM RATING
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA log or other proof does not indicate drain cover life span.
Correction: Indicate in the log the drain cover life span.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
GATES AND DOORS MECHANISM 54 INCHES
A self-closing latching and lockable mechanism is not present on the North gate.
Correction: Install a self-closing latching and lockable mechanism at least 54 inches from the bottom of the gate or door.
Code ATCP 76.34(2)(b) - SELF-CLOSING, LATCHING MECHANISM
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve or drain cover specifications.
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Source: Fond du Lac County Health Department. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.