Quality Inn And Suites
600 OASIS RD, Black River Falls, WI 54615 · Jackson County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Jackson County Public Health
- License / ID
- SWET-9VET4M
- Status
- Permitted
- Phone
- (715) 284-9471 ext. 0
- Official record
- Jackson County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 0 |
| 2025 | 1 | 7 | 0 |
| 2024 | 2 | 24 | 7 |
Inspections
-
Feb 18, 2026 Routine · 3 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 48ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
Mar 17, 2025 Routine · 7 non-critical, 2 repeat
-
Not serious
Non-critical
Corrected on site
SKIMMER POOL RECIRCULATION FLOW
Skimmer and main drain valves both open to 100%. Recirculation flow observed not to be 80% skimmer and 20% main drain.
Correction: Valves adjusted, recirculation flow adjusted to approximately 80% skimmer and 20% main drain.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Weir door on pool is missing.
Correction: Repair or replace weir door.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 35ppm for the pool.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool. Send a copy of combined chlorine action plan to Jackson County Public Health once complete.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Grates around the edge of pool room are bent/sticking up and creating a physical hazard.
Correction: Maintain pool deck area in good repair. Repair or replace grates.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Corrected on site
-
Feb 16, 2024 Re-inspection · 1 critical, 5 non-critical, 6 repeat
-
Not serious
Non-critical
Repeat
ACTION PLAN DEVELOPED
Operator is required to submit increased testing frequency to the department on a monthly basis.
Correction: Prepare and submit the required pool water chemistry test logs to the department by the 29th of each month beginning in February 2024.
Code ATCP 76.07(4)(a) - ACTION PLAN DEVELOPED
-
Not serious
Non-critical
Repeat
Corrected on site
SKIMMERS MAINTAINED CLEAN
Skimmer weir door is missing at pool.
Correction: Maintain the skimmers in clean condition. Operator purchased floating weirs for the pool, not on site during the inspection. Install floating weirs once on site for the pool.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. The operator did not know if a log was present at the time of inspection or if one was ever completed.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover. Equalizers must be added to the VGBA log to track replacement and life cycle.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. The paint used in the pool basin is cracking and peeling allowing the paint to be brought back through the recirculation system.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition. Cracking and peeling paint must be removed from pool basin, the pool basin and edges shall be resurfaced to prevent damage to the recirculation system.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Serious
Critical
Repeat
Corrected on site
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The metal grates on the outside edge of the pool are lifting up and bent, posing a risk for injury due to sharp and uneven edges.
Correction: Correct the hazardous condition. Replace or repair the metal grates on the outside edge of the pool before the pool is reopened to the public. Operator purchased new metal grate for the outside edge of the pool. Replace damaged metal grates once on site.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Repeat
-
Feb 13, 2024 Routine · 6 critical, 12 non-critical
-
Not serious
Non-critical
LICENSE NOT POSTED
The license is not posted for public view.
Correction: Post the license where it can be viewed by the public.
Code ATCP 76.05(7) - LICENSE POSTED
-
Not serious
Non-critical
ACTION PLAN DEVELOPED
An action plan is required by the department to demonstrate compliance with violations. Action plan must also include increase testing frequency to be submitted to the department on a monthly basis.
Correction: Prepare and submit the required Action Plan to the department or its agent.
Code ATCP 76.07(4)(a) - ACTION PLAN DEVELOPED
-
Not serious
Non-critical
SKIMMERS MAINTAINED CLEAN
Skimmers not maintained clean. Tennis ball, copper pipes, and debris was observed in the skimmer baskets. Skimmer weir door is missing at pool.
Correction: Maintain the skimmers in clean condition.
Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 529 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS STORAGE CONTAINER
Taylor test kit graduated cylinder is not maintained cleaned. Both cylinders on hand at the pool are discolored and not capable of producing accurate results.
Correction: Replace the Taylor test kit graduated cylinder so that accurate readings can be made using the kit and reagents.
Code ATCP 76.17 (2)(a) - REAGENT STORAGE BOTTLES
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
FIRST AID KIT-GAUZE ROLLER BANDAGES
The first aid kit is missing a gauze roller bandage, 4x4 gauze pads, gloves, 8x10 gauze pads, triangular bandage, and eye wash.
Correction: Provide a gauze roller bandage, 4x4 gauze pads, 8x10 gauze pads, triangular bandages, gloves and eyewash for the first aid kit.
Code ATCP 76.27(1)(b)3.- GAUZE ROLLER BANDAGES
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. The paint used in the pool basin is cracking and peeling allowing the paint to be brought back through the recirculation system.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition. Cracking and peeling paint must be removed from pool basin, the pool basin and edges shall be resurfaced to prevent damage to the recirculation system.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. The operator did not know if a log was present at the time of inspection or if one was ever completed.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
OPERATOR KNOWLEDGE-FLOW INTERLOCK FUNCTION
The person responsible is not able to describe how the system flow sensing interlock functions.
Correction: Ensure that operator can describe how the system flow sensing interlock functions.
Code ATCP 76.13 (1)(c)2.c - HOW FLOW INTERLOCK FUNCTIONS
-
Serious
Critical
OPERATOR KNOWLEDGE-MONTHLY TESTING
The person responsible is not able to describe how monthly testing is performed.
Correction: Ensure that operator can describe how monthly testing is performed.
Code ATCP 76.13 (1)(c)2.d - MONTHLY TESTING
-
Serious
Critical
OPERATOR KNOWLEDGE SAFETY DURING MONTHLY TESTING
The person responsible is not able to describe what safety measures that must be employed during monthly testing.
Correction: Ensure that operator can describe what safety measures that must be employed during monthly testing.
Code ATCP 76.13 (1)(c)2.e -MONTHLY TESTING SAFETY
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0.18 ppm for chlorine.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
CLOSING CRITERIA-FAILURE TO MEET 76.16
The Responsible Supervisor or operator has not closed the pool after failure to comply with the water quality requirements. The responsible supervisor has not closed the pool when water quality and disinfectant and pH ranges are outside of compliance.
Correction: Close the pool in the event of failure to comply with the water quality requirements pursuant to s. ATCP 76.16.
Code ATCP 76.30 (1)(b) - FAILURE TO MEET ATCP 76.16
-
Serious
Critical
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The metal grates on the outside edge of the pool are lifting up and bent, posing a risk for injury due to sharp and uneven edges.
Correction: Correct the hazardous condition. Replace or repair the metal grates on the outside edge of the pool before the pool is reopened to the public.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Source: Jackson County Public Health. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.