Coratel Inn & Suites
W10090 HWY 54 E, Black River Falls, WI 54615 · Jackson County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Jackson County Public Health
- License / ID
- BROG-B8GUHN
- Status
- Permitted
- Official record
- Jackson County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 7 | 2 |
| 2024 | 3 | 28 | 2 |
Inspections
-
Feb 16, 2026 Re-inspection · 2 critical, 5 non-critical, 2 repeat
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Wier door missing on skimmer.
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 38ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
BIOHAZARD KIT-BIOHAZARD DISPOSAL BAG
The biohazard kit is missing a biohazard disposal bag.
Correction: For the biohazard kit, provide a biohazard disposal bag.
Code ATCP 76.27(2)(b)6 - DISPOSAL BAG
-
Not serious
Non-critical
AIR MOVEMENT
Heating, ventilation, and exhaust equipment not maintained and operated to provide air movement to prevent any excessive condensation. Excess condensation observed in pool room, leading to growth of mold on ceilings and walls.
Correction: Maintain heating, ventilation, and exhaust equipment to provide air movement to prevent any excessive condensation. A referral to building inspection department or fire department will be made.
Code ATCP 76.33(4)(b) - AIR MOVEMENT
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Free chlorine is at 1.19ppm, free chlorine for whirlpool shall be at least 3.0ppm.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION
Phone in pool is observed to not be in working order.
Correction: Provide a reliable service connection for the communication technology.
Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI
-
Not serious
Non-critical
-
Mar 22, 2024 Re-inspection · 6 non-critical, 6 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The turnover rate for the whirl pool was 0.68 hrs.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of equal or less than 0.5hrs.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 56 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
Repeat
WATER HEATERS-MAINTAINED OPERATIONAL
Water heater or heat exchanger not in operating condition. The duct work to the whirl pool water heater is corroded and exhibits many holes in the piping which is venting back into the pool pump room.
Correction: Maintain water heater or heat exchanger in operating condition.
Code ATCP 76.33(4)(a) - MAINTAINED
-
Not serious
Non-critical
Repeat
-
Mar 18, 2024 Follow Up · 1 critical, 10 non-critical, 11 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The turnover rate for the whirl pool was 0.65 hrs.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of equal or less than 0.5hrs.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 52 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in the whirl pool which is not tested at least once a day for combined chlorine level.
Correction: Test pool water at least once a day for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
Repeat
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Whirl Pool water not tested at least once a week for total alkalinity. There was no record of alkalinity being recorded or tested on the pool chemistry log.
Correction: Test whirl pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING MAINTENANCE
The electronic monitoring device has not been periodically monitored for proper functioning .
Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate.
Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED
-
Not serious
Non-critical
Repeat
FIRST AID KIT ITEMS
The first aid kit is present but missing items. The first aid kit is missing adhesive tape and cold packs.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
Repeat
WATER HEATERS-MAINTAINED OPERATIONAL
Water heater or heat exchanger not in operating condition. The duct work to the whirl pool water heater is corroded and exhibits many holes in the piping which is venting back into the pool pump room.
Correction: Maintain water heater or heat exchanger in operating condition.
Code ATCP 76.33(4)(a) - MAINTAINED
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 2.07 ppm for liquid chlorine in the whirl pool.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Not serious
Non-critical
Repeat
-
Mar 12, 2024 Routine · 1 critical, 10 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. The turnover rate for the whirl pool was 0.65 hrs.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of equal or less than 0.5hrs.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 52 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in the whirl pool which is not tested at least once a day for combined chlorine level.
Correction: Test pool water at least once a day for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Whirl Pool water not tested at least once a week for total alkalinity. There was no record of alkalinity being recorded or tested on the pool chemistry log.
Correction: Test whirl pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
ELECTRONIC MONITORING MAINTENANCE
The electronic monitoring device has not been periodically monitored for proper functioning .
Correction: Periodically monitor the electronic monitoring device to determine if it is functioning correctly, and maintain and test as appropriate.
Code ATCP 76.18(3)(b) - ELECTRONIC MONITORING DEVICE MAINTAINED
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items. The first aid kit is missing adhesive tape and cold packs.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
WATER HEATERS-MAINTAINED OPERATIONAL
Water heater or heat exchanger not in operating condition. The duct work to the whirl pool water heater is corroded and exhibits many holes in the piping which is venting back into the pool pump room.
Correction: Maintain water heater or heat exchanger in operating condition.
Code ATCP 76.33(4)(a) - MAINTAINED
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 2.07 ppm for liquid chlorine in the whirl pool.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Not serious
Non-critical
Source: Jackson County Public Health. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.