Brf Hotel LLC
N6295 HOLIDAY DR E, Black River Falls, WI 54615 · Jackson County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Jackson County Public Health
- License / ID
- BROG-CLVMXG
- Status
- Permitted
- Phone
- (608) 642-1219
- Official record
- Jackson County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 1 |
| 2025 | 1 | 3 | 0 |
| 2024 | 2 | 20 | 7 |
Inspections
-
Jan 29, 2026 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 54.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Serious
Critical
RESCUE EQUIPMENT GOOD REPAIR
The ring buoy is not in good repair.
Correction: Maintain all rescue equipment in good repair.
Code ATCP 76.26(1)(a)1. - RESCUE EQPT GOOD REPAIR
-
Not serious
Non-critical
-
Jan 17, 2025 Routine · 3 non-critical
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing gauze roll, band aids, and elastic bandage.
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
-
Mar 11, 2024 Re-inspection · 4 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
FIRST AID KIT -GAUZE PADS
The first aid kit is missing 4x4 gauze pads, 8x10 gauze pads, gauze roll, band-aids, and elastic bandages.
Correction: Provide 4x4 gauze pads, 8x10 gauze pads, gauze roll, band-aids, and elastic bandages. for the first aid kit.
Code ATCP 76.27(1)(b)1. GAUZE PADS
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. The pool deck paint is chipping and cracking.
Correction: Maintain pool deck area in good repair. Resurfacing of the pool deck requires DSPS plan review, a plan review must be submitted before resurfacing of the pool deck.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
Feb 20, 2024 Routine · 7 critical, 9 non-critical
-
Not serious
Non-critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Current Inlets position has the potential to create dead spots in the pool.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 44 ppm.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 535 mV and water has not been tested manually.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
FIRST AID KIT -GAUZE PADS
The first aid kit is missing 4x4 gauze pads, 8x10 gauze pads, gauze roll, band-aids, and elastic bandages.
Correction: Provide 4x4 gauze pads, 8x10 gauze pads, gauze roll, band-aids, and elastic bandages. for the first aid kit.
Code ATCP 76.27(1)(b)1. GAUZE PADS
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator did not record the following on the operating report: Dates of interlock tests, results and comments.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. The pool deck paint is chipping and cracking.
Correction: Maintain pool deck area in good repair. Resurfacing of the pool deck requires DSPS plan review, a plan review must be submitted before resurfacing of the pool deck.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
POOL DECK-DEPTH MARKINGS MAINTAINED
Pool deck area not maintained so that depth markings along the edge of the pool are clearly visible and readable.
Correction: Maintain pool deck area so that depth markings along the edge of the pool are clearly visible and readable.
Code ATCP 76.33(1)(b)4. - DEPTH MARKINGS
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
CHEMICAL STORAGE ACCESS RESTRICTED
Chemical storage area access not restricted to authorized personnel. Chemical containers are not being stored where access to the public is restricted. Empty chemical barrels are not being removed from the premises and are stored outside.
Correction: Restrict access to chemical storage area to only authorized personnel.
Code ATCP 76.12 (2)(d) - ACCESS RESTRICTED
-
Serious
Critical
INTERLOCKED-FLOW
Recirculation flow is not interlocked with chemical feed, where required.
Correction: Provide interlock between the recirculation flow and the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.b. - FLOW INTERLOCK
-
Serious
Critical
AUTOMATIC AND CONTINUOUS DISINFECTION
Pool not automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment. The chemical feeder is being manually manipulated to feed chemical to the pool.
Correction: Ensure that each pool in use is automatically and continuously disinfected by means of disinfectant or sanitizer and feeding equipment that is in compliance with this section and s. ATCP 76.13.
Code ATCP 76.14 (1) - AUTOMATIC DISINFECTION
-
Serious
Critical
PH
The pH is 7.1.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Corrected on site
CLOSING CRITERIA-GATE OR DOOR NOT EQUIPPED TO SELF-CLOSE, LATCH, LOCKABLE
The Responsible Supervisor or operator has not closed the pool in the event that a gate or door is not equipped with a self-closing and latching mechanism, except when staffed by a lifeguard or attendant.
Correction: Close the pool in the event of a pool gate or door that is not equipped with a self-closing and latching mechanism, except when staffed by a lifeguard or attendant. Pool was closed to the public during the routine inspection until a latching mechanism is installed.
Code ATCP 76.30 (1)(i) - GATE OR DOOR NOT EQUIPPED TO SELF-CLOSE
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided. The drinking fountain was removed from the pool area. No approved variance for drinking water provided.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Serious
Critical
GATES AND DOORS-LATCHING
The gate or door does not latch. The main door entering the pool does not latch when the door is closed.
Correction: Provide a latching door.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
Source: Jackson County Public Health. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.