Days Inn
919 HWY 54 E, Black River Falls, WI 54615 · Jackson County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Jackson County Public Health
- License / ID
- KSMH-8KKTQP
- Status
- Permitted
- Phone
- (715) 284-9068
- Official record
- Jackson County Public Health inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 3 | 1 |
| 2024 | 6 | 38 | 17 |
Inspections
-
Jan 20, 2026 Routine · 1 critical, 2 non-critical
-
Not serious
Non-critical
Corrected on site
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Weir door missing from pool by the 3ft sign.
Correction: Corrected on sight, operator has ordered a replacement that will be arriving 1/26/26.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
VGBA DRAIN COVER INFO-LIFESPAN
The VGBA grates have exceeded their lifespan.
Correction: Replace grates with approved source and ensure lifespan is included in records.
Code ATCP 76.38(2)(b)4. - LIFESPAN
-
Serious
Critical
PH
The pH is 6.97.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Not serious
Non-critical
Corrected on site
-
Dec 5, 2024 Re-inspection 2 · No items found
No violations cited.
-
Nov 25, 2024 Re-inspection · 3 critical, 2 non-critical, 5 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Ladder on left side of pool is damaging the pool wall.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Serious
Critical
Repeat
Modification(s) made but no DSPS Approval available for them.
The operator modified a pool and did not submit pool construction plans to DSPS for review and approval.
Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool.
Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A
-
Serious
Critical
Repeat
CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS
Oxidizer is not stored separately from acid.
Correction: Store oxidizers separately from acids.
Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS
-
Serious
Critical
Repeat
OPERATOR KNOWLEDGE SAFETY DURING MONTHLY TESTING
The person responsible is not able to describe what safety measures that must be employed during monthly testing. Operator is not completing monthly testing.
Correction: Ensure that operator can describe what safety measures that must be employed during monthly testing.
Code ATCP 76.13 (1)(c)2.e -MONTHLY TESTING SAFETY
-
Not serious
Non-critical
Repeat
-
Nov 21, 2024 Routine · 3 critical, 7 non-critical, 3 repeat
-
Not serious
Non-critical
ACTION PLAN DEVELOPED
The Action Plan required by the department or its agent has not been provided.
Correction: Prepare and submit the required Action Plan to the department or its agent.
Code ATCP 76.07(4)(a) - ACTION PLAN DEVELOPED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Pool was not tested before opening to the public. Logs were unable to be provided during inspection.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
FIRST AID KIT ITEMS
The first aid kit is present but missing items (eyewash solution and pocket facemask).
Correction: Replace the missing items in the first aid kit.
Code ATCP 76.27(1)(b) - FIRST AID KIT ITEMS
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator did not record the following on the operating report: Results for chemical testing, interlock testing.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Pool basin not Maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. Ladder on left side of pool is damaging the pool wall.
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Serious
Critical
Repeat
Modification(s) made but no DSPS Approval available for them.
The operator modified a pool and did not submit pool construction plans to DSPS for review and approval.
Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool.
Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A
-
Serious
Critical
Repeat
CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS
Oxidizer is not stored separately from acid.
Correction: Store oxidizers separately from acids.
Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS
-
Serious
Critical
OPERATOR KNOWLEDGE SAFETY DURING MONTHLY TESTING
The person responsible is not able to describe what safety measures that must be employed during monthly testing. Operator is not completing monthly testing.
Correction: Ensure that operator can describe what safety measures that must be employed during monthly testing.
Code ATCP 76.13 (1)(c)2.e -MONTHLY TESTING SAFETY
-
Not serious
Non-critical
-
Feb 9, 2024 Re-inspection 2 · 1 critical, 1 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
There is no combined chlorine action plan present at the facility.
Correction: Develop a combined chlorine action plan for the facility. An example of a combined chlorine action plan will be provided with the report.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Serious
Critical
Repeat
Modification(s) made but no DSPS Approval available for them.
The operator modified a pool and did not submit pool construction plans to DSPS for review and approval.
Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool.
Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A
-
Not serious
Non-critical
Repeat
-
Feb 2, 2024 Re-inspection · 4 critical, 4 non-critical, 8 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The psi gauge on the high rate sand filter is not being maintained in operating condition. PSI gauge is broken and has not been replaced.
Correction: Repair the psi gauge on the high rate sand filter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
There is no combined chlorine action plan present at the facility.
Correction: Develop a combined chlorine action plan for the facility. An example of a combined chlorine action plan will be provided with the report.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
FIRST AID KIT -GAUZE PADS
The first aid kit is missing gauze pads, 8 x 10 gauze pads.
Correction: Provide gauze pads for the first aid kit.
Code ATCP 76.27(1)(b)1. GAUZE PADS
-
Not serious
Non-critical
Repeat
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Serious
Critical
Repeat
Modification(s) made but no DSPS Approval available for them.
The operator modified a pool and did not submit pool construction plans to DSPS for review and approval.
Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool.
Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A
-
Serious
Critical
Repeat
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Three inlets are missing from the swimming pool.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed. Replace the three missing inlets in the swimming pool.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Serious
Critical
Repeat
WATER SUPPLY PROTECTION
Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool, makeup tank, surge tank or slurry tank and another approved device does not exist.
Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.
Code ATCP 76.19(1) - PROTECTION
-
Serious
Critical
Repeat
GATES AND DOORS-SELF-CLOSING
The main door does not self-close and self latching. The latching mechanism to the door is missing. The sliding door leading to the exterior of the pool area is not locked to prevent unauthorized entry in the pool area.
Correction: Provide a self-closing door. Lock the sliding door so that there is no entry from the outside of the building.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
Repeat
-
Jan 30, 2024 Routine · 6 critical, 7 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The psi gauge on the high rate sand filter is not being maintained in operating condition. PSI gauge is broken and has not been replaced.
Correction: Repair the psi gauge on the high rate sand filter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
SAFETY DATA SHEET
Safety data sheets were not available for the chemicals used in the facility .
Correction: Maintain safety data sheets for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
There is no combined chlorine action plan present at the facility.
Correction: Develop a combined chlorine action plan for the facility. An example of a combined chlorine action plan will be provided with the report.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. Multiple reagents in the Taylor test kit are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
FIRST AID KIT -GAUZE PADS
The first aid kit is missing gauze pads, 8 x 10 gauze pads, gauze roll, triangular bandage, eye wash.
Correction: Provide gauze pads, eye wash, gauze roll, and triangular bandages for the first aid kit.
Code ATCP 76.27(1)(b)1. GAUZE PADS
-
Not serious
Non-critical
OPERATING REPORTS-BACKWASH
The operator did not record the following on the operating report: The dates on which backwashing was completed.
Correction: Record the following on the operating report, the dates when backwashing was completed.
Code ATCP 76.32(1)(b) - BACKWASH
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. No VGBA log provided to the inspector during routine inspection.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Modification(s) made but no DSPS Approval available for them.
The operator modified a pool and did not submit pool construction plans to DSPS for review and approval.
Correction: Have WI-licensed architect or engineer submit pool construction (modification) plans to DSPS and obtain approval from DSPS for the construction of the pool.
Code ATCP 76.04 (2) - PLANS SUBMITTED TO DSPS FOR MODIFICATION, A
-
Serious
Critical
INLETS CHECKED AND ADJUSTED
Inlets have not been checked and adjusted to ensure a uniform distribution pattern and effective skimming. Three inlets are missing from the swimming pool.
Correction: Check and adjust inlets to ensure a uniform distribution pattern and effective skimming as needed. Replace the three missing inlets in the swimming pool.
Code ATCP 76.11(2)(c) - INLETS POSITIONED
-
Serious
Critical
Corrected on site
CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS
Liquid Chlorine is not stored separately from Sulfuric Acid.
Correction: Store oxidizers separately from acids.
Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS
-
Serious
Critical
ELECTRONIC MONITORING FREQUENCY OF TESTING
The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual.
Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.
Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ
-
Serious
Critical
WATER SUPPLY PROTECTION
Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool, makeup tank, surge tank or slurry tank and another approved device does not exist.
Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.
Code ATCP 76.19(1) - PROTECTION
-
Serious
Critical
GATES AND DOORS-SELF-CLOSING
The main door does not self-close. The sliding door leading to the exterior of the pool area is not locked to prevent unauthorized entry in the pool area.
Correction: Provide a self-closing door. Lock the sliding door so that there is no entry from the outside of the building.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
Source: Jackson County Public Health. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.