Best Western Watertown - Pool
101 AVIATION WAY, Watertown, WI 53094 · Jefferson County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Jefferson County Health Department / Watertown
- License / ID
- KMAN-CWAPFB
- Status
- Permitted
- Phone
- (920) 262-1910
- Official record
- Jefferson County Health Department / Watertown inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 5 | 1 |
| 2025 | 1 | 1 | 0 |
| 2024 | 4 | 3 | 0 |
| 2023 | 3 | 20 | 6 |
Inspections
-
Jul 22, 2026 Routine · 1 critical, 4 non-critical
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
POOl water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Last date of testing observed 7/18.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
POSTING SIGNAGE-SUPERVISION OF CHILDREN
At a non-lifeguarded pool, no signage stating that children under 12 must be supervised is present.
Correction: Post signage stating that children under 12 must be supervised.
Code ATCP 76.29(1)(c) - SUPERVISE CHILDREN
-
Not serious
Non-critical
FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION
The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.
Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.
Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER
-
Serious
Critical
Corrected on site
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jul 10, 2025 Routine · 1 non-critical
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for the pool chemicals.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
-
Apr 11, 2024 Routine · 1 non-critical
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement for the equalizer covers.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
-
Mar 6, 2024 Pre-inspection Follow Up · No items found
No violations cited.
-
Feb 6, 2024 Pre-inspection Follow Up · 2 non-critical, 2 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 200.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 645 mV and water has not been tested manually at the proper frequency.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
Repeat
-
Jan 12, 2024 Re-inspection · No items found
No violations cited.
-
Dec 11, 2023 Pre-inspection Follow Up · 1 critical, 2 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 200.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 645 mV and water has not been tested manually at the proper frequency.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Repeat
-
Nov 7, 2023 Pre-inspection Follow Up · 2 critical, 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 200.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 645 mV and water has not been tested manually at the proper frequency.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
WATER HEATERS-MAINTAINED OPERATIONAL
Water heater or heat exchanger has been removed.
Correction: Maintain water heater or heat exchanger in operating condition.
Code ATCP 76.33(4)(a) - MAINTAINED
-
Serious
Critical
RESPONSIBLE SUPERVISOR AVAILABLE AND RESPOND
Responsible supervisor's phone number is not posted by the emergency telephone number.
Correction: Have the responsible supervisor respond within 15 minutes when action is needed.
Code ATCP 76.21 (1)(b) - NOT AVAILABLE WITHIN 15 MINUTES
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Repeat
-
Oct 10, 2023 Pre-inspection · 3 critical, 9 non-critical
-
Not serious
Non-critical
DOORS
The doors to the pump room are not marked to indicate entry is for authorized personnel only
Correction: Mark doors.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 200.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 645 mV and water has not been tested manually at the proper frequency.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS REPLACED
Alkalinity and calcium hardness reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
POOL RULES SIGNAGE-NO DIAPER CHANGING ON DECK
Pool rules missing rule: Diaper changing on the pool deck is prohibited.
Correction: Include pool rule on sign: Diaper changing on the pool deck is prohibited.
Code ATCP 76.29(1)(b)1.f. - NO DIAPER CHANGING ON DECK
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area is cracked/chipped by depth markers and not maintained in good repair.
Correction: Maintain pool deck area in good repair.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
WATER HEATERS-MAINTAINED OPERATIONAL
Water heater or heat exchanger has been removed.
Correction: Maintain water heater or heat exchanger in operating condition.
Code ATCP 76.33(4)(a) - MAINTAINED
-
Serious
Critical
RESPONSIBLE SUPERVISOR AVAILABLE AND RESPOND
Responsible supervisor's phone number is not posted by the emergency telephone number.
Correction: Have the responsible supervisor respond within 15 minutes when action is needed.
Code ATCP 76.21 (1)(b) - NOT AVAILABLE WITHIN 15 MINUTES
-
Serious
Critical
TELEPHONE-LOCATION
The telephone or other approved communication technology is not within 25 feet of pool area. A phone that can dial out 911 is not available within 25 feet of pool area.
Correction: Provide a telephone or other telecommunication technology device that is within 25 feet of pool area.
Code ATCP 76.26(2)(c) - TELEPHONE, LOCATION
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Source: Jefferson County Health Department / Watertown. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.