Best Western Watertown - Whirlpool
101 AVIATION WAY, Watertown, WI 53094 · Jefferson County
Establishment
- Type
- Pool / recreational water (Pool - Moderate)
- Inspected by
- Jefferson County Health Department / Watertown
- License / ID
- KMAN-CWAPG4
- Status
- Permitted
- Phone
- (920) 262-1910
- Official record
- Jefferson County Health Department / Watertown inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 0 | 0 |
| 2025 | 2 | 3 | 0 |
| 2024 | 7 | 6 | 3 |
| 2023 | 3 | 17 | 6 |
Inspections
-
Aug 4, 2026 Routine · No items found
No violations cited.
-
Jul 10, 2025 Routine · 2 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter was not functioning at time of inspection.
Correction: Repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
SAFETY DATA SHEET
A safety data sheet was not available for pool chemicals.
Correction: Maintain a safety data sheet for each chemical on site.
Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS
-
Not serious
Non-critical
-
Jan 7, 2025 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is OUT.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
-
Dec 3, 2024 Re-inspection · No items found
No violations cited.
-
May 2, 2024 Re-inspection · No items found
No violations cited.
-
Apr 12, 2024 Re-inspection · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement for the equalizer covers.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Not serious
Non-critical
Repeat
-
Apr 11, 2024 Routine · 1 critical, 1 non-critical
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement for the equalizer covers.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
MAXIMUM BROMINE
The maximum total bromine exceeds 10 ppm.
Correction: Close the pool until the total bromine residual is in compliance with Table ATCP 76.14 Table A.
Code ATCP 76.14(5)(g) -MAXIMUM BROMINE
-
Not serious
Non-critical
-
Feb 9, 2024 Re-inspection 2 · No items found
No violations cited.
-
Feb 9, 2024 Re-inspection · 2 critical
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 3 for Bromine in a Whirlpool.
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is 6.6.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
-
Feb 6, 2024 Pre-inspection Follow Up · 1 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 210.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
-
Dec 11, 2023 Pre-inspection Follow Up · 1 critical, 2 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 210.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 605 mV and water has not been tested manually at the proper frequency.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Repeat
-
Nov 7, 2023 Pre-inspection Follow Up · 2 critical, 2 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 210.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 605 mV and water has not been tested manually at the proper frequency.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Serious
Critical
Repeat
RESPONSIBLE SUPERVISOR AVAILABLE AND RESPOND
Responsible supervisor's phone number is not posted by the emergency phone.
Correction: Have the responsible supervisor respond within 15 minutes when action is needed.
Code ATCP 76.21 (1)(b) - NOT AVAILABLE WITHIN 15 MINUTES
-
Serious
Critical
Repeat
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Repeat
-
Oct 10, 2023 Pre-inspection · 3 critical, 7 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition.
Correction: Adjust or repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
DOORS
The doors to the pump room are not marked to indicate entry is for authorized personnel only
Correction: Mark doors.
Code ATCP 76.12 (2)(i) - DOORS
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 210.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 605 mV and water has not been tested manually at the proper frequency.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS REPLACED
Alkalinity and calcium hardness reagents are expired.
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY
Whirlpool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY
-
Not serious
Non-critical
POSTING SIGNAGE- NO PROLONGED BREATH HOLDING
Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.
Correction: Provide signage or provide other communication warning against prolonged breath holding.
Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING
-
Serious
Critical
RESPONSIBLE SUPERVISOR AVAILABLE AND RESPOND
Responsible supervisor's phone number is not posted by the emergency phone.
Correction: Have the responsible supervisor respond within 15 minutes when action is needed.
Code ATCP 76.21 (1)(b) - NOT AVAILABLE WITHIN 15 MINUTES
-
Serious
Critical
TELEPHONE-LOCATION
The telephone or other approved communication technology is not within 25 feet of pool area. A telephone that can dial 911 is not available within 25 feet of the pool area.
Correction: Provide a telephone or other telecommunication technology device that is within 25 feet of pool area.
Code ATCP 76.26(2)(c) - TELEPHONE, LOCATION
-
Serious
Critical
DRINKING FOUNTAIN PROVIDED
There is no drinking fountain provided.
Correction: Provide a drinking fountain within 300 feet walking distance.
Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED
-
Not serious
Non-critical
Source: Jefferson County Health Department / Watertown. History last read Oct 5, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.