RecordWell Data

Cedar Springs Gas & Camp

N7001 HWY 58, New Lisbon, WI 53950 · Juneau County

15cited violations
0serious tier
5inspections

Establishment

Type
Campground (Campground 51-100 Sites (RC3))
Inspected by
Juneau County Health Department
License / ID
LMAE-CATR28
Status
Permitted
Phone
(608) 847-7676
Official record
Juneau County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026120
2025290
2024130
2023110

Inspections

  1. Jun 10, 2026 Routine · 2 non-critical
    • Not serious Non-critical

      Approved sanitary station design standards

      The sanitary station does not meet construction requirements for SPS 382.37 (2). *Referral will be made to Juneau County Sanitation and Zoning.

      Correction: Repair the sanitary station or provide approval of current sanitary station by Juneau County Sanitation and Zoning..

      Code ATCP 79.15 (2) (b)

    • Not serious Non-critical

      Toilet buildings- clean and good repair

      The women's restroom has multiple dead insects on and in the sink.

      Correction: Maintain the toilet building in a clean condition and in good repair.

      Code [C] ATCP 79.16 (1) (a)

  2. May 29, 2025 Re-inspection · 4 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      Site designation

      Various campsites are not clearly marked with an alpha or numeric symbol that is a minimum of 2 inches in height and visible from the campground’s internal road system.

      Correction: Provide each campsite with a clearly marked alpha or numeric symbol that is a minimum of 2 inches in height and visible from the campground’s internal road system.

      Code ATCP 79.11 (2)

    • Not serious Non-critical Repeat

      Water system-backflow protection

      Various water service connections throughout campground are not provided with approved backflow prevention devices.

      Correction: Provide water service connections with approved backflow prevention devices.

      Code ATCP 79.14 (4) (c)

    • Not serious Non-critical Repeat

      POWTS access covers

      POWTS access covers observed unsecured.

      Correction: Secure POWTS access cover with a locking device.

      Code ATCP 79.15 (1) (c)

    • Not serious Non-critical Repeat

      Approved sanitary station design standards

      The sanitary station does not meet construction requirements for SPS 382.37 (2).

      Correction: Repair the sanitary station.

      Code ATCP 79.15 (2) (b)

  3. May 14, 2025 Routine · 5 non-critical, 3 repeat
    • Not serious Non-critical

      Site designation

      Various campsites are not clearly marked with an alpha or numeric symbol that is a minimum of 2 inches in height and visible from the campground’s internal road system.

      Correction: Provide each campsite with a clearly marked alpha or numeric symbol that is a minimum of 2 inches in height and visible from the campground’s internal road system.

      Code ATCP 79.11 (2)

    • Not serious Non-critical

      Water system-backflow protection

      Various water service connections throughout campground are not provided with approved backflow prevention devices.

      Correction: Provide water service connections with approved backflow prevention devices.

      Code ATCP 79.14 (4) (c)

    • Not serious Non-critical Repeat

      POWTS access covers

      POWTS access covers observed unsecured.

      Correction: Secure POWTS access cover with a locking device.

      Code ATCP 79.15 (1) (c)

    • Not serious Non-critical Repeat

      Approved sanitary station design standards

      The sanitary station does not meet construction requirements for SPS 382.37 (2).

      Correction: Repair the sanitary station.

      Code ATCP 79.15 (2) (b)

    • Not serious Non-critical Repeat

      Shower building-slip resistant flooring

      Shower room floors are not provided with a slip-resistant mat.

      Correction: Provide shower-room floors with slip resistant coverings or non-absorbent, easily cleanable matting.

      Code [A] ATCP 79.17 (2)

  4. May 15, 2024 Routine · 3 non-critical, 1 repeat
    • Not serious Non-critical

      POWTS access covers

      POWTS access covers observed unsecured.

      Correction: Secure POWTS access cover with a locking device.

      Code ATCP 79.15 (1) (c)

    • Not serious Non-critical

      Approved sanitary station design standards

      The sanitary station does not meet construction requirements.

      Correction: Repair the sanitary station.

      Code ATCP 79.15 (2) (b)

    • Not serious Non-critical Repeat

      Shower building-slip resistant flooring

      Shower room floors do not have slip resistant mats.

      Correction: Provide shower-room floors with slip resistant coverings or non-absorbent, easily cleanable matting.

      Code [A] ATCP 79.17 (2)

  5. May 10, 2023 Routine · 1 non-critical
    • Not serious Non-critical

      Shower building-slip resistant flooring

      Shower room floors are not slip resistant.

      Correction: Provide shower-room floors with slip resistant coverings or non-absorbent, easily cleanable matting.

      Code [A] ATCP 79.17 (2)

Source: Juneau County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.