Cottage Keeper - Cozy Cottage @ Shipwreck

N7265 SHACKS RD, Mauston, WI 53948 · Juneau County

7cited violations
3serious tier
2inspections

Establishment

Type
Lodging (Tourist Rooming House - 1 TRH)
Inspected by
Juneau County Health Department
License / ID
VELT-DFRQPR
Status
Permitted
Phone
(888) 404-2688
Official record
Juneau County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2026173
2025100

Inspections

  1. Apr 23, 2026 Routine · 7 non-critical
    • Serious Critical

      Smoke alarms provided

      Smoke alarms are not provided within each individually keyed unit.

      Correction: Provide smoke alarms within each individually keyed unit at the locations specified in rule.

      Code ATCP 72.18(11)(a)

    • Serious Critical

      Windows used for exiting - 20 inches x 24 inches

      The [describe location] window used for exiting has a window opening of [00 inches x 00 inches].

      Correction: Provide a window opening at least 20 inches by 24 inches irrespective of the height or width, or provide a different exit, or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(g)2.

    • Serious Critical

      Closing criteria - absence of a required smoke alarm

      The operator shall close the [applicable affected areas] of a lodging facility due to the absence of a required smoke alarm.

      Correction: The operator shall close the applicable individually keyed unit, lodging facility, or affected areas of a lodging facility where an imminent health hazard is present.

      Code ATCP 72.26(1)(e)

    • Not serious Priority Foundation

      Smoke alarm installed outside each separate sleeping area

      A smoke alarm is not provided outside of each separate sleeping area, within 21 feet of any door to a sleeping room. The [describe location] does not have a smoke alarm.

      Correction: Provide a smoke alarm outside of each separate sleeping area, within 21 feet of any door to a sleeping room.

      Code ATCP 72.18(11)(b)2.

    • Not serious Priority Foundation

      Bed spacing >= 2' egress aisle

      Beds are not arranged to provide an aisle at least 2 feet in width from one side of each bed to create a clear path for emergency egress.

      Correction: Rearrange or remove bed(s) to provide an aisle at least 2 feet in width from one side of each bed to create a clear path for emergency egress.

      Code ATCP 72.18(3)(b)1.

    • Not serious Priority Foundation

      Windows used for exiting - platform for windows > 46 inches above floor

      The [describe location] window used for exiting does not have a permanent platform or fixture installed.

      Correction: Provide a permanent platform or fixture that is at least 20 inches wide and 9 inches deep is located no more than 46 inches directly below the clear opening, or provide a different exit, or discontinue sleeping from that floor.

      Code ATCP 72.18(4)(g)5.

    • Not serious Priority Foundation

      Building evacuation diagram (TRH) - posted or provided

      The building evacuation diagram is not conspicuously posted in each sleeping room or is not provided in the check-in materials.

      Correction: Post the building evacuation diagram in each sleeping room or provide in the check-in materials given to guests.

      Code ATCP 72.18(6)(b)1.

  2. May 7, 2025 Pre-inspection · No items found

    No violations cited.

Source: Juneau County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.