Bucks Crossing-swimming Pool
150 S EAST ST, Lyndon Station, WI 53944 · Juneau County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Juneau County Health Department
- License / ID
- VELT-B44P5X
- Status
- Permitted
- Phone
- (608) 666-3009
- Official record
- Juneau County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 2 | 0 |
| 2025 | 2 | 7 | 1 |
| 2024 | 1 | 5 | 3 |
| 2023 | 1 | 0 | 0 |
Inspections
-
Jun 22, 2026 Routine · 2 non-critical
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
A list of emergency numbers and facility address not attached or posted near telephone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
-
Jun 5, 2025 Re-inspection · No items found
No violations cited.
-
Jun 4, 2025 Routine · 1 critical, 6 non-critical, 1 repeat
-
Not serious
Non-critical
CHEMICAL FEEDERS USED-AUTOMATIC
Chlorine chemical feeder is not automatic. Feeder is not hooked up chemicals and not operational.
Correction: Repair or replace an automatic chemical feeder. (A plan review may be required if replaced).
Code ATCP 76.13 (1)(b)1. - AUTOMATIC
-
Not serious
Non-critical
Repeat
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
COMBINED CHLORINE TEST
Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level.
Correction: Test pool water at least twice a week for the combined chlorine level.
Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity.
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
RESCUE EQUIPMENT ACCESSIBLE
The rescue equipment is not in a conspicuous place and readily accessible. Make sephards crooks easily accessilbe to patrons.
Correction: Maintain rescue equipment in a conspicuous and accessible location.
Code ATCP 76.26(1)(a)2. - RESCUE EQPT ACCESSIBLE
-
Not serious
Non-critical
VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT
The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.
Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.
Code ATCP 76.38(2)(a) - DRAIN COVER LOG
-
Serious
Critical
Corrected on site
CLOSING CRITERIA-NON-OPERATIONAL RECIRD PUMP
The Responsible Supervisor or operator has not closed the pool when there is a nonoperational circulation pump, filter, or disinfectant or sanitizer feeder.
Correction: Close the pool in the event of a nonoperational circulation pump, filter, or disinfectant or sanitizer feeder.
Code ATCP 76.30 (1)(d) - NON-OPERATIONAL RECIRC PUMP
-
Not serious
Non-critical
-
Jun 17, 2024 Routine · 3 critical, 2 non-critical
-
Not serious
Non-critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
[Pool] water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Not serious
Non-critical
SOAP-PROVIDED
Soap not provided in permanently-installed dispensing device.
Correction: Provide soap in a permanently-installed dispensing device.
Code ATCP 76.33 (2)(e)1. - SOAP
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is [ 0] for [chlorine].
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is [ 6.8].
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
CO ALARM-POOL EQUIPMENT ROOM
There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room.
Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.
Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM
-
Not serious
Non-critical
-
Jun 21, 2023 Routine · No items found
No violations cited.
Source: Juneau County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.