Arrowhead Resort Campground Diving Pool
W1530 ARROWHEAD, Wisconsin Dells, WI 53965 · Juneau County
Establishment
- Type
- Pool / recreational water (Pool - Simple)
- Inspected by
- Juneau County Health Department
- License / ID
- HSAT-7QX3BC
- Status
- Permitted
- Phone
- (608) 254-7344
- Official record
- Juneau County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 1 | 1 |
| 2025 | 2 | 7 | 1 |
| 2024 | 4 | 24 | 8 |
| 2023 | 1 | 4 | 0 |
Inspections
-
Jul 21, 2026 Routine · 1 critical
-
Serious
Critical
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, or within 25 feet of enclosure with signage posted in the enclosure telling where the first aid kit is.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
-
Jul 14, 2025 Re-inspection · 3 non-critical, 3 repeat
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
Repeat
SOAP-PROVIDED
Soap not provided in permanently-installed dispensing device.
Correction: Provide soap in a permanently-installed dispensing device.
Code ATCP 76.33 (2)(e)1. - SOAP
-
Not serious
Non-critical
Repeat
-
Jul 9, 2025 Routine · 1 critical, 3 non-critical, 1 repeat
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
POSTING SIGNAGE-MAX PATRON LOAD
Maximum patron load is not posted.
Correction: Post signage indicating Maximum patron load.
Code ATCP 76.29(1)(e) - MAX PATRON LOAD
-
Not serious
Non-critical
SOAP-PROVIDED
Soap not provided in permanently-installed dispensing device.
Correction: Provide soap in a permanently-installed dispensing device.
Code ATCP 76.33 (2)(e)1. - SOAP
-
Serious
Critical
TELEPHONE ACCESSIBLE
A telephone or other approved communication technology capable of connecting to emergency services is not working or not present.
Correction: Provide a working telephone or other technology capable of connecting with emergency services.
Code ATCP 76.26(2)(a) - TELEPHONE ACCESSIBLE
-
Not serious
Non-critical
Repeat
-
Jul 12, 2024 Re-inspection 2 · 2 critical, 4 non-critical, 6 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not operational
Correction: repair the flowmeter
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
SHOWERS-OPERABLE
Showers not maintained in an operable condition.
Correction: Maintain showers in an operable condition.
Code ATCP 76.33 (2)(b) - SHOWERS OPERABLE
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is at 0 ppm
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
GATES AND DOORS-SELF-CLOSING
The gate or door does not self-close.
Correction: Provide a self-closing gate or door.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
Repeat
-
Jul 11, 2024 Re-inspection 2 · 2 critical, 4 non-critical, 6 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not operational
Correction: repair the flowmeter
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
SHOWERS-OPERABLE
Showers not maintained in an operable condition.
Correction: Maintain showers in an operable condition.
Code ATCP 76.33 (2)(b) - SHOWERS OPERABLE
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is at 0 ppm
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
GATES AND DOORS-SELF-CLOSING
The gate or door does not self-close.
Correction: Provide a self-closing gate or door.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
Repeat
-
Jul 9, 2024 Routine · 2 critical, 4 non-critical
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not operational
Correction: repair the flowmeter
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
SHOWERS-OPERABLE
Showers not maintained in an operable condition.
Correction: Maintain showers in an operable condition.
Code ATCP 76.33 (2)(b) - SHOWERS OPERABLE
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is at 0 ppm
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
GATES AND DOORS-SELF-CLOSING
The gate or door does not self-close.
Correction: Provide a self-closing gate or door.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
-
Jul 9, 2024 Re-inspection · 2 critical, 4 non-critical, 6 repeat
-
Not serious
Non-critical
Repeat
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not operational
Correction: repair the flowmeter
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
Repeat
INTERLOCK-LOG KEPT
A log of the monthly interlock tests is not being kept.
Correction: Keep a log of monthly interlock tests.
Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT
-
Not serious
Non-critical
Repeat
COMBINED CHLORINE PLAN PRESENT
The operator has not developed and implemented a plan to minimize combined chlorine in the pool.
Correction: Develop and implement a plan to minimize combined chlorine in the pool.
Code ATCP 76.14(5)(e)1. - PLAN PRESENT
-
Not serious
Non-critical
Repeat
SHOWERS-OPERABLE
Showers not maintained in an operable condition.
Correction: Maintain showers in an operable condition.
Code ATCP 76.33 (2)(b) - SHOWERS OPERABLE
-
Serious
Critical
Repeat
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is at 0 ppm
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
Repeat
GATES AND DOORS-SELF-CLOSING
The gate or door does not self-close.
Correction: Provide a self-closing gate or door.
Code ATCP 76.34(4)(a)(1m)(a) -SELF-CLOSING
-
Not serious
Non-critical
Repeat
-
Jul 18, 2023 Routine · 4 non-critical
-
Not serious
Non-critical
CHEMICAL STORAGE
Chemicals are not stored in accordance with ATCP 76.12(2).
Correction: Store chemicals in accordance with ATCP 76.12(2). This has been an ongoing issue and needs to be corrected prior to the 2024 season.
Code ATCP 76.12(2)
-
Not serious
Non-critical
EQUIPMENT NOT MAINTAINED
The handrails around the pool are loose and can be pulled out.
Correction: Repair and maintain all equipment pursuant to ATCP 76.33(1)(e).
Code ATCP 76.33(1)(e)
-
Not serious
Non-critical
SHOWERS NOT MAINTAINED
The showers in the men's bathroom are not functioning properly.
Correction: Repair the showers so they are in compliance with ATCP 76.33(2)(b).
Code ATCP 76.33(2)(b)
-
Not serious
Non-critical
DEPTH MARKINGS FADED
The depth markings along the edge of the pool are completely falling apart.
Correction: Repair the markings so they are clearly visible and readable.
Code [B] ATCP 76.33(1)(b)
-
Not serious
Non-critical
Source: Juneau County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.