City Council Meeting — Agenda Packet
City of Fort Atkinson · Jefferson County · City Council · meeting of Oct 6, 2026 · Agenda packets
Open the original document More from City of Fort Atkinson
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
CITY COUNCIL MEETING
IN PERSON AND VIA ZOOM
TUESDAY, OCTOBER 6, 2026 – 7:00 PM
CITY HALL – SECOND FLOOR
https://us02web.zoom.us/j/5997866403?pwd=alcreldSbGpNUVI1VnR1RWF5bXovdz09&omn=85105919995
Meeting ID: 599 786 6403
Passcode: 53538
Dial by Location
+1 312 626 6799
If you have special needs or circumstances which may make communication or accessibility
difficult at the meeting, please call (920) 397-9901. Accommodations will, to the fullest extent
possible, be made available on request by a person with a disability.
AGENDA
1. Call meeting to order
2. Roll call
3. Pledge of Allegiance
4. Consent Agenda: The Consent Agenda outlined below is hereby presented for action by the
City Council. Items may be removed from the Consent Agenda on the request of any one
Council member. Items not removed may be adopted by one action without debate.
Removed items may be taken up either immediately after the Consent Agenda or placed
later on the agenda at the discretion of the Council President.
a. Review and possible action relating to the minutes of September 1, 2026,
Ordinance Committee meeting (Ebbert/Clerk/Treasurer/Finance Director
b. Review and possible action relating to the minutes of the September 9, 2026 Parks
and Recreation Advisory Board meeting (Dayton, Parks and Recreation Director)
c. Review and possible action relating to the minutes of the September 10, 2026,
Finance Committee meeting (Ebbert, Clerk/Treasurer/Finance Director)
d. Review and possible action relating to the minutes of the September 15, 2026,
License Committee meeting (Ebbert, Clerk/Treasurer/Finance Director)
e. Review and possible action relating to the minutes of the September 15, 2026, City
Council meeting (Ebbert, Clerk/Treasurer/Finance Director)
Page 1 of 271
f. Review and possible action relating to the minutes of the September 22, 2026,
Plan Commission meeting (Ebbert, Clerk/Treasurer/Finance Director)
g. Review and possible recommendation relating to Alcohol Beverage License Agent
Change DLM Group LLC, dba Jennies Entertainment Center, 1245 Whitewater
Avenue (Ebbert, Clerk/Treasurer/Finance Director)
h. Review and possible recommendation relating to Alcohol Beverage License Name
Change ("DBA" Change) for Creamery 201, LLC dba Vallarta Bar and Grill, LLC at 201
N. Main Street (Ebbert, Clerk/Treasurer/Finance Director)
i. Review and possible action relating to the installation of assistive listening
technology in Dwight Foster Public Library's FCCU Community Room (Lippert,
Library Director)
j. Review and possible action relating to Citizen Appointments to Boards,
Commissions and Committees (Houseman, City Manager)
k. Review and possible action relating to a Temporary Retailer's License for BASE
Common Table Harvest Dinner on October 10, 2026, from 4:00 pm - 10:00 pm
(Ebbert, Clerk/Treasurer/Finance Director)
5. Public Hearings
6. Public Comment for Matters on the Agenda: The City Council will receive comments from
City residents. Comments are generally limited to three minutes per individual. Anyone
wishing to speak is required to sign up in advance or state the following items for the record
when called upon: name, address, and contact information. No action will be taken on any
public comments unless the item is also elsewhere on the agenda.
7. Petitions, Requests, and Communications
a. Referendum presentation (Fort Atkinson School District representatives)
8. Resolutions and Ordinances
a. Review and possible action relating to a Resolution Adopting the 2027 Stormwater
Utility Rate (Navin, Director of Public Works)
b. Review and possible action relating to a Resolution Adopting the 2027 Wastewater
Utility Rates (Navin, Director of Public Works)
c. First reading of a proposed Annexation Ordinance relating to the annexation of the
property located at N1807 South Main Street (parcel number 016-0514-0941-030)
to the City of Fort Atkinson from the Town of Koshkonong (PFA-2026-02) (Draeger,
Director of Neighborhood and Building Services)
d. Second and possible third/final reading of an Ordinance to Amend Section 18-256
of the City of Fort Atkinson Code of General Ordinances relating to Camping Units
(Draeger, Director of Neighborhood and Building Services)
Page 2 of 271
e. Second and possible third/final reading of an Ordinance amending Chapter 94,
Article VIII, Division 6 Stopping, Standing and Parking (Lindsey, Police Captain)
f. Second reading of an Ordinance to amend Section 98-603 and create Section 98-
610 of Article V of the City of Fort Atkinson Code of General Ordinances relating to
the Stormwater Utility (Navin, Director of Public Works)
9. Reports of Officers, Boards, and Committees
a. City Manager’s Report (Houseman, City Manager)
10. Unfinished Business
11. New Business
a. Review and possible action relating to a Water and Wastewater Capacity
Evaluation by Donohue & Associates, Inc. (Navin, Director of Public Works)
b. Review and possible action relating to a proposal for preparation and
implementation of a Wisconsin Economic Development Corporation Site
Assessment grant application for the former Loeb-Lorman Scrapyard (Navin,
Director of Public Works)
c. Review and possible action relating to Banker Road Redesign Temporary Limited
Easements (Navin, Director of Public Works)
d. Review and possible action relating to Replacement of Aeration G5 Plus 100 HP
Turbo Blower (Sweeney, Wastewater Superintendent)
e. Review and possible action relating to the purchase of ambulance capital
equipment (Peterson, Fire Chief)
f. Review and possible action relating to the purchase of two Mobile Data Terminals
for the Fire Department CAD System using donated funds (Peterson, Fire Chief)
g. Review and possible action on CIP Back-up Generator Replacement Project for
Police Department (Bump, Police Chief)
h. Review and possible action relating to the Small Animal Collection Contract with
the Humane Society of Jefferson County for 2027 (Ebbert, Clerk/Treasurer/Finance
Director)
12. Miscellaneous
13. Public Comment for Matters Not on the Agenda: The City Council will receive comments
from City residents. Comments are generally limited to three minutes per individual. Anyone
wishing to speak is required to sign up in advance or state the following items for the record
when called upon: name, address, subject matter, and contact information. No action will
be taken on any public comments.
Page 3 of 271
14. Claims, Appropriations and Contract Payments
a. Review and possible action relating to the Verified Claims presented by the
Director of Finance and authorization of payment (Ebbert, Clerk/Treasurer/Finance
Director)
15. Adjournment
Date Posted:
CC: City Council; City Staff; City Attorney; News Media; Fort Atkinson School District; Fort
Atkinson Chamber of Commerce
Visit us online! City news and information can be found at www.fortatkinsonwi.gov, and be sure
to follow us on Facebook @FortAtkinsonWI.
Page 4 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
ORDINANCE COMMITTEE MEETING
IN PERSON AND VIA ZOOM
TUESDAY, SEPTEMBER 1, 2026 – 6:00 PM
CITY HALL – SECOND FLOOR
MINUTES
1. Call meeting to order
President Jaeckel called the meeting to order at 6:00 pm.
2. Roll call
Present: Cm. Huckabee, Cm. Price and President Jaeckel. Also present: City Manager,
Clerk/Treasurer/Finance Director, Director of Public Works, Director of Neighborhood Services,
Police Captain and Police Chief.
3. Unfinished Business
None.
President Jaeckel stated that those in the audience were allowed to address the Committee
within a 3-minute public comment section.
Brad Wilcox, 508 Frederick Ave - President of Evergreen Cemetery Association. Supports
Ordinance #1 (Land-use reduction) and opposes Ordinance #2 (stormwater credit).
4. New Business
a. Review, discussion, and possible recommendation to the City Council relating to
amendments to the Stormwater Utility Ordinance, Chapter 98 of the City of Fort Atkinson
Municipal Code (Navin, Director of Public Works)
Director Navin advised that the Ordinance Committee has requested that staff prepare an
amendment to the City's stormwater utility ordinance that would remove cemetery
properties from stormwater utility charges. The City's stormwater utility currently assesses
properties based on their contribution to and use of the community's stormwater
management system. Cemetery properties are presently treated in the same manner as
other applicable non-residential properties and are assessed based on the City's
established stormwater utility rate structure. In response to the Committee's request,
staff reviewed the financial and policy implications of establishing a full exemption for
cemeteries, as well as how other municipalities have approached similar requests.
Staff believes cemetery properties should continue to contribute toward the operation
Page 5 of 271
and maintenance of the City's stormwater system. While cemeteries have unique land-use
characteristics that warrant consideration, a complete exemption is not the preferred
mechanism for recognizing those characteristics. Rather than creating a categorical
exemption, staff recommends addressing the unique nature of cemetery properties
through a more targeted land-use reduction and the City's stormwater credit policy.
Recommended Alternative: 25% Cemetery Land-Use Reduction. A 25% reduction in
stormwater utility charges for qualifying cemetery properties based on the inherent
characteristics of cemetery land use.
The reduction would recognize that cemeteries generally contain:
• substantial areas of permanent open space;
• relatively low building coverage;
• limited intensity of development; and • significant areas capable of infiltration and
reduction of stormwater runoff.
Under this approach, cemeteries would remain part of the stormwater utility rate
structure but would automatically receive a 25% reduction in recognition of these land-
use characteristics.
Two forms of relief are provided as:
1. Land-Use Reduction: A 25% reduction recognizing the inherent characteristics of
cemetery properties.
2. Stormwater Credits: Additional reductions based on demonstrated stormwater
management benefits or qualifying practices.
Huckabee moved, seconded by Price to recommend to the City Council Exemption Article
V for review. Motion carried.
b. Review and possible recommendation to the City Council relating to penalties for violations
of the City's traffic ordinances (stopping, standing, and parking) (Lindsey, Police Captain)
Captain Lindsey the City's current parking ordinance establishes specific forfeiture and
penalty amounts for parking violations directly within the ordinance. As a result, any
future adjustment to parking related fees requires a formal ordinance amendment. The
proposed revision would remove the specific penalty amounts from the ordinance and
instead reference a fee schedule adopted annually by the City Council. This approach
separates the fee structure and provides greater flexibility for the City to review and
adjust parking related fees as needed through the annual fee schedule adoption process.
This change does not alter the City's authority to regulate parking or enforce parking
restrictions, nor does it change the parking regulations.
If recommended by the Ordinance Committee and adopted by the City Council, the
effective date would be January 1, 2027. Staff will propose a new series of fees relating to
parking violations in the 2027 draft fee schedule to be reviewed by the Finance Committee
at the meeting on September 10, 2026.
Huckabee moved, seconded by Price to recommend the proposed ordinance amendments
Page 6 of 271
to the City Council. Motion carried.
5. Adjournment
Huckabee moved, seconded by Price to adjourn. Meeting adjourned at 6:15 pm.
Respectfully submitted,
Michelle Ebbert
City Clerk/Treasurer/Finance Director
Page 7 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
PARKS AND RECREATION ADVISORY BOARD MEETING
IN PERSON AND VIA TEAMS
WEDNESDAY, SEPTEMBER 9, 2026 – 4:00 PM
CITY HALL – SECOND FLOOR
MINUTES
1. Call meeting to order
President Jaeckel called the meeting to order at 4:02 pm
2. Roll call
Present Bm. Baird, Dary, Scheckel, Baird, Heath, President Jaeckel and School Rep. Mahoney.
Also present: Josh Bennett
Absent: Bm. Dorfman
3. Election of the Chair of the Parks and Recreation Board
Jaeckel called for nominations.
Heath nominated himself, seconded by Mahoney.
4. Election of the Vice Chair of the Parks and Recreation Board
Heath called for nominations.
Jaeckel nominated Scheckel, and Mahone seconded.
5. Approval of Minutes
a. Review and possible action relating to the minutes of the June,10 2026 Parks and
Recreation Advisory Board meeting (Chair)
Jaeckel moved, seconded by Scheckel, to approve the June 9, 2026 Parks and Recreation
Advisory Board meeting minutes. Motion carried.
6. Unfinished Business
None
7. New Business
a. Fort Atkinson Parks and Recreation Virtual Park Facilities Tour Presentation (Director
Page 8 of 271
Dayton)
Director Dayton led Advisory Board members on a virtual tour of key facilities throughout
the City's parks system, including the Aquatic Center, Haumerson's Pond Warming House,
Barrie Park, Jones Park, Memorial Park, Ralph Park, Rock River Park, and the Theater
Facade. The tour highlighted the condition of these facilities and provided context for
current and future maintenance and improvement needs.
b. Jones Park Baseball Scoreboard Improvements Fort Atkinson Generals (Josh Bennett)
Bennett shared an overview of the Fort Atkinson Generals baseball organization and its
partnership with the City's Parks and Recreation Department. Since 2001, the Generals
have operated what is now known as Baseball Fest at Jones Park. The home-talent
organization receives annual support from approximately 44 local businesses and partners
with numerous community organizations that volunteer in the concession stand as a
fundraiser for their groups. Since 2001, the Generals have donated approximately $7,000
annually to support improvements at Jones Park, totaling roughly $152,000 , and recently
partnered with the Parks Department to help raise funds for the Jones Park batting cage
project.
Bennett explained that the Generals organization is interested in replacing the right-field
scoreboard and is seeking feedback from the Parks and Recreation Advisory Board before
entering the Public Monument Review Process. He outlined three potential funding
options: using a donation received by both the Generals and the Parks Department
through the estate of Lloyd Knopfel; running a fundraising campaign and pursuing a
matching grant through the Community Foundation; or securing corporate sponsorships.
Bennett noted that the current City ordinance does not allow permanent business
advertising in parks, meaning an ordinance amendment would likely be required to
accommodate sponsorship opportunities. He also inquired about the possibility of adding
the name of the donor associated with the project.
Dayton explained that while temporary event-related advertising, such as signage during
Baseball Fest, is permitted, the ordinance currently prohibits permanent advertising within
parks. He added that granting perpetual naming rights to an individual or business would
require careful consideration and approval. Dayton also raised concerns regarding long-
term maintenance costs, noting that responsibilities could ultimately fall to the City if the
user group is no longer able to provide support.
Mahoney shared information about the School District of Fort Atkinson's sponsorship
program, which has helped fund facility improvements through corporate partnerships.
Scheckel noted that the Fort Atkinson Youth Baseball Board has also expressed interest in
pursuing corporate sponsorship opportunities.
Dayton discussed successful partnerships that have supported past park improvements.
He noted that collaborating with service organizations that have secured corporate
Page 9 of 271
donations for large projects has been successful. He mentioned Rotary Pavilion and
Rotary Depot shelter operations as examples.
Dayton stated that if the ordinance is amended, the Parks and Recreation Advisory Board
and City staff will need to establish clear policies and guidelines governing donor
recognition and signage within City parks.
Baird suggested that Jones could be a potential partner for the scoreboard project.
Bennett agreed and noted that the company already provides annual support to the
organization.
8. Miscellaneous
a. Director's Report
Each September, we celebrate our seniors for National Senior Center Month. At the
September 1st council meeting, we recognized our folks with a proclamation. I was
honored to speak about Chris Nye, our Senior Center Director, and Crystal Porter, our
part-time assistant there, and to highlight the amazing work they do. They provide many
positive programs and services for the community. It was exciting to present them with
that proclamation.
We have a few fun upcoming events through the Parks and Recreation Department.
On Friday, September 11th, we’ll host our Adult Recess Remix from 6 to 8:30 P.m. The
event will feature a live DJ and concessions from the Generals. This year, families are
welcome to attend together, so you won’t necessarily need to find a babysitter.
There will also be an adults-only, 21-plus playground lounge area where guests can hang
out without necessarily having kids in their group. Also, World of Wheels is on Saturday
the 12th from 9:30 a.m. to 11 a.m. That's at Ralph Park. The first 30 minutes of the
program are siren-free, so kids or folks with sensitive ears can safely go out there and
enjoy the event as well.
Aquatic Center:
The Aquatic Center was hopping this year. We welcomed an impressive 28, 752 visitors
this season. As you recall, it was kind of an odd summer. Last year, we had almost
31,000 visitors, but this is several years in a row that we've been around the 30,000 mark.
For the second year in a row, we were able to stay open for an additional three bonus
days in August, thanks to our awesome part- time staff!
The Aquatic Center officially started accepting credit cards for the 2026 season. From June
through July, we received 2,943 credit card payments. About 21% of all payments were
made through the new credit card system. During that period, 27% of concession sales
Page 10 of 271
were paid by credit card, and 34% of admissions were as well. We weren't necessarily
expecting that, so it'll be interesting to compare these numbers in the years to come and
see how this trend may change.
If you recall, June brought several days of heat that continued into July. On one day, we
had nearly 1000 people, and staff reported that about 300 came through the front gate
within the first half hour. It was an interesting time down there, and we definitely felt it at
the concession stand, selling out of quite a few items because you can't always predict
that kind of crowd.
Our lowest attendance was on opening day, when 69 people showed up on a cold and
rainy afternoon.
This year, staff provided 800 kids with public swim lessons and 105 kids with private
lessons. This was possible because a large group of staff decided to get their swimming
lesson certifications or become certified to teach swim lessons. We had a high-achieving
group of staff members, which offered us the ability to provide more private lessons
during that time.
Main Street Dance Studio:
We held our popular dance intensive class again this summer. In that class, 30 participants
went through a variety of more technical dance techniques and continued practicing their
skills throughout the summer.
We also offered our summer dance program. In session one, we had 164 registrations, and
in session two, we had 182. I don't know if you've heard me say this before, but our dance
program here rivals many private entities. We provide a very high-quality program, so it's
impressive to see it offered through a Park and Recreation agency.
During our opening weekend of dance registration, we saw an incredible $31,000 in online
transactions. Right now, only 9 of our 29 classes remain open, while all classes for children
six and under are completely full. It’s clear community members are taking advantage of
this asset.
Parks:
Matt Thompson, our aquatic specialist, received a promotion and now serves as the city's
facility manager. So we congratulate Matt and are happy he took that step. However, we
are now at the end of the pool season, and we had to work through closing the pool. We
are nearing the end of a job search and hope to have the position filled soon.
The update to Section 62 of the city's ordinance amendments, which was reviewed by this
board, went through two readings at council and will have its third and final reading at the
next council meeting on September 15th.
Page 11 of 271
Recreation:
As mentioned in a previous meeting, we updated the door access system this year and will
introduce a new procedure for renters using the municipal building gym. This will improve
security and eliminate the need to manage physical keys or pick them up at the police
department. It was a worthwhile improvement.
The table and chair program also received an upgrade. We purchased new commercial-
grade chairs with plastic seats and backs that are lighter—which is a huge benefit—and
easier to transport. They will soon be put into circulation, and we expect them to be a
positive change for our rental program and the people who use it.
In July, Heather Fox, our administrative assistant program coordinator, left us for a great
opportunity as the senior center coordinator in her home community of Jefferson. I want
to give congratulations to her! The job search attracted 28 candidates. We narrowed the
pool to six for interviews. We selected two individuals for a second interview. I'm excited
to share that Lacy Edwards, who previously worked at Fort Atkinson Middle School,
accepted the position and started on August 31st. She's already doing a great job and
making an impact.
Senior Center:
The Senior Center Board Inc. will host another Brat Bash fundraiser this Saturday,
September 12th, from 11 a.m. to 2 p.m. Proceeds go to the Senior Center Board, Inc., their
friends group, supporting facility improvements, scholarships for seniors who cannot
afford certain trips or events, presentations, and entertainment. It has been a great
partnership.
I want to highlight two of their most recent contributions: the installation of a new cabinet
and countertop for the coffee station, matching the existing countertop and replacing a
folding table and small serving cart. They also donated a red bike rack, visible from the
senior center. This is forward-thinking, as current and future seniors may travel by bike.
9. Next Meeting
a. Next Meeting: Wednesday, December 9, 2026, at 4:00 p.m.
10. Adjournment
Jaeckel moved, seconded by Scheckel, to adjourn. Meeting Adjourned at 5:12 p.m.
Page 12 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: September 9, 2026
TO: Committee/Commission/Board
FROM:
RE: Jones Park Baseball Scoreboard Improvements Fort Atkinson Generals (Josh
Bennett)
BACKGROUND
Each year, the Fort Atkinson Generals baseball team partners with the Parks and Recreation
Department staff to explore ways to collaborate on park improvement projects that benefit the
park and the user groups that call it their home field.
DISCUSSION
The Fort Atkinson Generals are interested in upgrading the scoreboard at Jones Park. The
project is in its early stages, and the Generals would like to discuss with the Parks and
Recreation Advisory Board to gather feedback.
FINANCIAL ANALYSIS
None
RECOMMENDATION
N/A
ATTACHMENTS
1. 530856BAC_JONES_1 ad panel
2. 530856BACD_JONES_2 ad panels
Page 13 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
FINANCE COMMITTEE MEETING
IN PERSON
THURSDAY, SEPTEMBER 10, 2026 – 5:00 PM
CITY HALL – SECOND FLOOR
MINUTES
1. Call meeting to order
President Jaeckel called the meeting to order at 5:00 pm.
2. Roll call
Present: Cm. Huckabee, Cm. Lescohier and President Jaeckel. Also present: City Manager, City
Clerk/Treasurer/Finance Director, Director of Public Works, Director of Neighborhood Services
and Park & Recreation Director.
3. Public Comment
a. The Finance Committee will receive public comments relating to matters on the agenda.
Speakers must be City residents, property owners, or business representatives. Comments
are generally limited to three minutes per individual. Anyone wishing to speak is required
to sign up in advance or state the following items for the record when called upon: name,
address, subject matter, and contact information.
None.
4. New Business
a. Review and possible recommendation to the City Council relating to the draft 2027
Schedule of Fees (Houseman, City Manager)
Lescohier moved, seconded by Huckabee to recommend the City Council approve the
2027 Schedule of Fees. Motion carried.
b. Review and possible action relating to the City's Compensation Philosophy, an Appendix to
the Employee Handbook (Houseman, City Manager)
Huckabee moved, seconded by Lescohier to approve the City's Compensation Philosophy,
an Appendix to the Employee Handbook. Motion carried.
c. Review and possible action relating to a requested Cost of Living Adjustment to be included
in the 2027 budget for full-time non-represented City employees (Houseman, City
Manager)
Huckabee moved, seconded by Lescohier to approve the requested 2% COLA for full-time
Page 14 of 271
non-represented employees to be included in the 2027 budget. Motion carried.
d. Review and possible action relating to requested wage adjustments to be included in the
2027 budget for part-time and seasonal City staff (Houseman, City Manager)
Lescohier moved, seconded by Huckabee to approve the wage adjustments to be included
in the 2027 budget for part-time and seasonal City staff to be included in the 2027 budget.
Motion carried.
5. Adjournment
Huckabee moved, seconded by Lescohier to adjourn. Meeting adjourned at 6:03 pm.
Respectfully submitted
Michelle Ebbert
City Clerk/Treasurer/Finance Director
Page 15 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: September 10, 2026
TO: Committee/Commission/Board
FROM: Rebecca Houseman, City Manager
RE: Review and possible action relating to a requested Cost of Living Adjustment to
be included in the 2027 budget for full-time non-represented City employees
(Houseman, City Manager)
BACKGROUND
Annually at the September Finance Committee meeting, staff presents a proposed Cost of
Living Adjustment, or COLA, to be included in the following year's operating budget. In 2027,
staff is proposing a 2% COLA.
DISCUSSION
Due to the proposed changes in the compensation philosophy based on the Classification and
Compensation Report (2025) and the Performance Management Program (2026), staff is
proposing a nominal cost of living adjustment in 2027 of 2% for full-time non-represented
employees. Additional increases are available for employees who are between the minimum
and the midpoint of the pay range (systematic) and those between the midpoint and the
maximum of the pay range (merit).
Whitewater, Jefferson County, and Johnson Creek are all proposing a 3% COLA for 2027.
Per the approved contract, WPPA Police Union members will receive a 4% increase in hourly
wages. Per the approved contract with FF Local 580, Fire Union members will receive a 4%
increase in hourly wages.
FINANCIAL ANALYSIS
If the requested COLA is approved by the Finance Committee, it will be incorporated into the
2027 operating budget document.
RECOMMENDATION
Staff recommends that the Finance Committee approve the requested 2% COLA for full-time
non-represented employees.
Page 16 of 271
ATTACHMENTS
1. 2027 Pay Grades and Ranges
Page 17 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
LICENSE COMMITTEE MEETING
IN PERSON
TUESDAY, SEPTEMBER 15, 2026 – 6:15 PM
CITY HALL – SECOND FLOOR, CONFERENCE ROOM
MINUTES
1. Call meeting to order
President Jaeckel called the meeting to order at 6:15 pm.
2. Roll call
Present: Cm. Lescohier, Cm. Price and President Jaeckel. Also present: City Manager and City
Clerk/Treasurer/Finance Director.
3. New Business
a. Review and possible recommendation to the City Council relating to Alcohol Beverage
License Agent Change DLM Group LLC, dba Jennies Entertainment Center, 1245
Whitewater Avenue (Ebbert, Clerk/Treasurer/Finance Director)
Clerk Ebbert provided that within State Statutes, the Agent of an LLC must be a resident of
the State. The agent noted for DLM Group, LLC dba Jennie's Entertainment Center located
at 1245 Whitewater Avenue has since moved out of Wisconsin and therefore must
appoint a new agent. The appointment of agent and individual questionnaire was
submitted by Romie Johnson. There is a $10.00 agent fee change associated with this
request.
Cm. Lescohier moved, seconded by Price to recommend the City Council approve of the
agent change for DLM Group, LLC dba Jennie's Entertainment Center at 1425 Whitewater
Avenue for the licensing period of October 7, 2026 through June 30, 2027. Motion carried.
b. Review and possible recommendation to the City Council relating to Alcohol Beverage
License Name Change ("DBA" Change) for Creamery 201, LLC dba Vallarta Bar and Grill,
LLC at 201 N. Main Street (Ebbert, Clerk/Treasurer/Finance Director)
Clerk Ebbert provided that Creamery, 201 LLC has submitted a request to change the DBA
(doing business as) for their location at 201 N. Main Street Ste. 220. Creamery 201 has a
"Class B" Intoxicating Liquor and Class "B" Fermented Malt Beverage license. The request
is to operate as Vallarta Bar and Grill at said location. There is no change to the premises
description and is as provided: Second floor of 201 N Main Street, hallways and outdoor
enclosed area, Suite 220 and outdoor seating area. The premise includes the event venue
and the attached restaurant with outdoor patio.
Page 18 of 271
Price moved, seconded by Lescohier to recommend the City Council approve the dba
change for Creamery 201, LLC to dba Vallarta Bar and Grill, LLC for use at 201 N. Main
Street Ste 220 for the licensing period of October 7, 2026 through June 30, 2027. Motion
carried.
4. Adjournment
Price moved, seconded by Lescohier to adjourn. Meeting adjourned at 6:22 pm.
Respectfully submitted,
Michelle Ebbert
City Clerk/Treasurer/Finance Director
Page 19 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: September 15, 2026
TO: Committee/Commission/Board
FROM: Michelle Ebbert, Clerk/Treasurer/Finance Director
RE: Review and possible recommendation to the City Council relating to Alcohol
Beverage License Agent Change DLM Group LLC, dba Jennies Entertainment
Center, 1245 Whitewater Avenue (Ebbert, Clerk/Treasurer/Finance Director)
BACKGROUND
The State of Wisconsin regulates alcohol licensing for local governments through Chapter 125.
Alcohol Licenses issued to Limited Liability Companies must appoint an agent to operate the
business. Agent responsibilities per Statute are listed below:
(6) Licenses to corporations and limited liability companies; appointment of agents.
125.04(6)(a)(a) Agent. No corporation or limited liability company organized under the laws of
this state or of any other state or foreign country may be issued any alcohol beverage license or
permit unless:
125.04(6)(a)1. 1. The entity first appoints an agent in the manner prescribed by the authority
issuing the license or permit. In addition to the qualifications under sub. (5), the agent must,
with respect to character, record and reputation, be satisfactory to the issuing authority.
125.04(6)(a)2. 2. The entity vests in the agent, by properly authorized and executed written
delegation, full authority and control of the premises described in the license or permit of the
entity, and of the conduct of all business on the premises relative to alcohol beverages, that the
licensee or permittee could have and exercise if it were a natural person.
125.04(6)(b) (b) Successor agent. A corporation or limited liability company may cancel the
appointment of an agent and appoint a successor agent to act in the agent's place, for the
remainder of the license year or until another agent is appointed, as follows:
125.04(6)(b)1. 1. The successor agent shall meet the same qualifications required of the first
appointed agent.
125.04(6)(b)2. 2. The entity shall immediately notify the issuing authority, in writing, of the
appointment of the successor agent and the reason for the cancellation and new appointment.
125.04(6)(c) (c) Authority of successor. A successor agent shall have all the authority, perform
all the functions and be charged with all the duties of the previous agent of the corporation or
limited liability company until the next regular or special meeting of the issuing authority if a
license is held. However, the license of the corporation or limited liability company shall cease to
be in force if, prior to the next regular or special meeting of the issuing authority, the clerk of the
licensing authority receives notice of disapproval of the successor agent by a peace officer of the
Page 20 of 271
municipality issuing the license.
DISCUSSION
DLM Group, LLC dba Jennie's Entertainment Center, located at 1245 Whitewater Avenue, has
submitted a request for an agent change. Agents for licensed establishments manage many
aspects of a business including scheduling, hiring, ordering of product, and managing finances.
A background check was performed on the applicant without concerns.
Per State Statute, 125.04(5)(a)(2) Individuals, all natural persons in a partnership and the agents
of corporations and limited liability companies are subject to 90 day continuous residency in
this state prior to the date of application. The prior agent had since moved out of Wisconsin,
therefore requiring the assignment of a new agent.
FINANCIAL ANALYSIS
There is a $10 fee associated with an agent change.
RECOMMENDATION
Staff recommends that the License Committee recommends to the City Council approval of the
agent change for DLM Group, LLC dba Jennie's Entertainment Center at 1425 Whitewater
Avenue for the licensing period of October 7, 2026 through June 30, 2027.
ATTACHMENTS
1. DLM Group Agent Appointment Romie Johnson_Redacted
Page 21 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: September 15, 2026
TO: Committee/Commission/Board
FROM: Michelle Ebbert, Clerk/Treasurer/Finance Director
RE: Review and possible recommendation to the City Council relating to Alcohol
Beverage License Name Change ("DBA" Change) for Creamery 201, LLC dba
Vallarta Bar and Grill, LLC at 201 N. Main Street (Ebbert,
Clerk/Treasurer/Finance Director)
BACKGROUND
The State of Wisconsin regulates alcohol licensing for local governments through Chapter 125.
Local governments are given the authority to issue licenses where alcohol is consumed in a
public place in accordance with requirements set forth by Statute. There are three classes of
Licenses: Class A, Class B, and Class C. “Class C” pertains strictly to wine with consumption on-
site in a restaurant. The difference between Class A and B is where alcohol is authorized for sale
and for consumption. Class A generally offers sale of alcohol on-site with consumption off-site
(e.g. grocery or liquor store, gas station or convenience store). Class B allows for on-site sale
and on-site consumption (e.g. Restaurant, Bar, Bowling Alley, Tavern). Class A can easily be
remembered as you consume alcohol Away from the premises. Likewise, Class B you consume
on-site, for example Bar.
DISCUSSION
Creamery, 201 LLC has submitted a request to change the DBA (doing business as) for their
location at 201 N. Main Street Ste. 220. Creamery 201 has a "Class B" Intoxicating Liquor and
Class "B" Fermented Malt Beverage license. The request is to operate as Vallarta Bar and Grill
at said location. There is no change to the premises description and is as provided: Second floor
of 201 N Main Street, hallways and outdoor enclosed area, Suite 220 and outdoor seating area.
The premise includes the event venue and the attached restaurant with outdoor patio.
FINANCIAL ANALYSIS
There are no fees associated with a DBA change.
RECOMMENDATION
Staff recommends that the License Committee recommend to City Council to approve the dba
change for Creamery 201, LLC to dba Vallarta Bar and Grill, LLC for use at 201 N. Main Street for
Page 22 of 271
the licensing period of October 7, 2026 through June 30, 2027.
ATTACHMENTS
1. Creamery 201 - Vallarta Bar and Grill 09042026
Page 23 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
CITY COUNCIL MEETING
IN PERSON AND VIA ZOOM
TUESDAY, SEPTEMBER 15, 2026 – 7:00 PM
CITY HALL – SECOND FLOOR
MINUTES
1. Call meeting to order
President Jaeckel called the meeting to order at 7:00 pm.
2. Roll call
Present: Cm. Huckabee, Cm. Johnson, Cm. Lescohier, Cm. Price and President Jaeckel. Also
present: City Manager, City Attorney, City Clerk/Treasurer/Finance Director, Director of Public
Works, Director of Neighborhood and Building Services, Public Works Superintendent, Police
Chief, Police Captain and Park & Recreation Director.
3. Pledge of Allegiance
President Jaeckel led the Pledge of Allegiance.
4. Consent Agenda
Price moved, seconded by Johnson to approve the Consent Agenda as presented items 4.a.
through 4.m. Motion carried.
a. Review and possible action relating to the minutes of the September 1, 2026, City Council
meeting (Ebbert, Clerk/Treasurer/Finance Director)
b. Review and possible action relating to the minutes of the September 10, 2026
Transportation and Traffic Review Committee (Ebbert, Clerk/Treasurer/Finance Director)
c. Review and possible action relating to building, plumbing, and electrical permit report for
August 2026 (Draeger, Director of Neighborhood and Building Services)
d. Review and possible action relating to the City Clerk-issued License and Permit Report for
September (Ebbert, Clerk/Treasurer/Finance Director)
e. Review and possible action relating to City Sewer, Water, and Stormwater Utility
Financial Statements as of August 31, 2026 (Ebbert, Clerk/Treasurer/Finance Director)
f. Review and possible action relating to a Temporary Retailer's License for Rotary Club of
Fort Atkinson Wine Walk, on October 17, 2026. (Ebbert, Clerk/Treasurer/Finance Director)
g. Review and possible action on a Special Event: Rotary Wine Walk Saturday, Oct. 17, 2026,
from 12:00-4:00 pm in downtown Fort Atkinson (Ebbert, Clerk/Treasurer/Finance
Director)
Page 24 of 271
h. Review and possible action on a Special Event: Haunted Hike Friday, Oct. 16, 2026 and
Saturday, Oct. 17, 2026 from 6 to 9 pm at Haumerson's Pond (Ebbert,
Clerk/Treasurer/Finance Director)
i. Review and possible action on a Special Event: HFH Fill-A-Truck, Thursday, October 11,
2026 from 10:00 am - 2:00 pm (Ebbert, Clerk/Treasurer/Finance Director)
j. Review and possible action on a Special Event: Chamber of Commerce, Holiday
Parade, Sunday, December 6, 2026, 4:03 p.m. - 6:00 p.m. (Ebbert, Clerk/Treasurer/Finance
Director)
k. Review and possible action on a Special Event: Kiwanis Trunk or Treat, Saturday, October
31, 2026, 6:00 - 8:00 pm at Jones Park (Ebbert, Clerk/Treasurer/Finance Director)
l. Review and possible action relating to Citizen Appointments to Boards, Commissions and
Committees (Houseman, City Manager)
m. Review and possible action on a Special Event: Fort Nutrition You Matter: Suicide
Prevention 1-mile walk Sunday, September 27, 2026 from 9 am to 12 pm at Fort
Nutrition and the Bike path (Ebbert, Clerk/Treasurer/Finance Director)
5. Public Hearings
None.
6. Public Comment for Matters on the Agenda
Alan Goldberg, 704 Frederick Avenue - supported the Ordinance regarding Stormwater Utility
in regard to cemetery exemption from stormwater rates.
Curtis Abendroth, 1000 N. Main Street - stated that the stormwater runoff in the street was not
coming from the cemetery on Main Street.
Brad Wilcox, 508 Frederick Avenue - supports the amendment to the stormwater ordinance
that exempts cemeteries.
Betty Strese, 408 Curtis Circle - read an article from the Daily Union published in 2021 in regard
to Evergreen Cemetery.
7. Petitions, Requests, and Communications
a. Presentation: Affordable Housing Program (Kristen Fish-Peterson, Redevelopment
Resources)
Kristin Fish-Peterson of Redevelopment Resources shared a presentation on the
Affordable Housing Program. No action was taken.
b. Presentation: City of Fort Atkinson Adopt a Storm Drain Program (Navin, Director of Public
Works)
Page 25 of 271
Director Navin presented the Adopt a Storm Drain Program. No action was taken.
8. Resolutions and Ordinances
a. Review and possible action relating to a Resolution requesting exemption from the County
Library Tax for the City of Fort Atkinson (Houseman, City Manager)
Manager Houseman stated the Jefferson County Board has established a County Library
Service and levies a County Library Tax. State Statutes provide that a municipality is
exempt from this County Library Tax if the municipality levies a minimum amount for
public library services. Annually in September, the County calculates the minimum levy for
municipalities to qualify for this exemption. Per the attached documentation and statutory
calculation, the City is required to appropriate at least $331,699 to the Dwight Foster
Public Library to be exempt from the tax. The City is proposing to levy $650,400 in
property taxes to fund Library operations in 2027. This amount exceeds the minimum
appropriation for exemption from the County Library Tax. The proposed amount to be
levied ($650,400) represents an increase of $13,400 over the 2026 levied amount of
$637,000, or just over 2%.
Lescohier moved, seconded by Johnson to adopt the Resolution requesting exemption
from the County Library Tax and direct the City Clerk to provide copies of the Resolution to
the County Clerk and the Jefferson County Library Council Administrator. Motion carried.
b. Second and possible third/final reading of an Ordinance regarding an amendment to
Section 6-33 of the City of Fort Atkinson Municipal Code relating to provisional operator
licenses (Ebbert, Clerk/Treasurer/Finance Director)
Clerk Ebbert explained that a provisional operator license is a license that can be issued up
to 60 days to an Operator License applicant during the interm of applying for such license
and receiving the license. A provisional license will allow an individual to work at a
licensed establishment while their operator license is being processed. Current ordinances
does not acknowledge that a Provisional License can be issued to an Operator License
application upon proof of completion of a responsible beverage server course or proof of
enrollment in a responsible beverage server course. State recommends the language be
amended to include providing completion of a training course or confirms enrollment in a
training course. The Ordinance Committee reviewed this item at their meeting on July 21,
2026, and recommended to City Council for review. The City Council approved the first
reading at their September 1, 2026 meeting.
Lescohier moved, seconded by Huckabee to suspend the rules and offer a third/final
reading of the Ordinance. Motion carried unanimously.
Huckabee moved, seconded by Johnson to approve the Ordinance amending Sections 6-33
of the City of Fort Atkinson Municipal Code relating to provisional operator licenses.
Motion carried.
Page 26 of 271
c. Third/final reading and possible adoption of an Ordinance to amend Section 58-148 of the
City of Fort Atkinson Municipal Code relating to the sale of tobacco, nicotine products,
electronic smoking devices, and electronic smoking device paraphernalia near certain
locations (Bump, Police Chief)
Captain Lindsey shared that the main goal of section 58-148(d)(3) of the Fort Atkinson City
ordinance is to reduce the availability and visibility of smoking products that include
Tobacco, Vape, Electronic Smoking Devices, Electronic Smoking Device Paraphernalia,
Pipes, Hookahs, Rolling Papers, and other miscellaneous nicotine consumables and smoke
products to youth. The City Council performed a first reading of this Ordinance at the
meeting on August 15, 2026 and voted to amend the Ordinance to remove parks from the
list of prohibited locations. The attached Substitute Amendment #1 reflects these changes
from the original amendment presented on August 15th.
Huckabee moved, seconded by Johnson to approve the Ordinance with Substitute
Amendment #1 amending Section 58-148 of the City of Fort Atkinson Municipal Code
relating to the sale of tobacco, nicotine products, electronic smoking devices, and
electronic smoking device paraphernalia in certain locations. Motion carried.
d. Third/final reading and possible adoption of an Ordinance to amend multiple sections of
Chapter 62 of the City of Fort Atkinson Municipal Code of Ordinances relating to park
regulations (Dayton, Director of Parks and Recreation)
Director Dayton stated that Staff provided the Recreation Advisory Board subcommittee
with a proposal adopting new ordinance to prohibit smoking, vaping, and the use of e-
cigarettes within city parks and on public trails. Additionally, revisions were recommended
to existing ordinances regarding pets on designated park property, protection of City
property within the parks system, glass bottle restrictions, and park hours of operation.
These amendments are intended to align current usage of park facilities with City
ordinance. The City Council performed the first reading at the meeting on August 18th.
After a proposed amendment to change the areas where smoking would be prohibited in
parks failed, the motion to direct the City Manager to prepare the ordinance for a second
reading carried. The second reading was held September 1.
Price moved, seconded by Lescohier to approve the Ordinance amending multiple sections
of Chapter 62 of the City of Fort Atkinson Municipal Code of Ordinances relating to park
regulations. Motion carried.
e. First reading of an Ordinance amending Chapter 94, Article VIII, Division 6 Stopping,
Standing and Parking (Lindsey, Police Captain)
Captain Lindsey shared that the proposed ordinance revision removes specific parking
forfeiture and penalty amounts from the parking ordinance and instead establishes those
amounts within the City's annual fee schedule. Under the current ordinance, penalty
amounts are specified within the ordinance itself, requiring a formal ordinance
amendment whenever a fee adjustment is necessary. This change does not alter the City's
Page 27 of 271
authority to regulate parking or enforce parking restrictions. It does modify the method by
which forfeiture amounts are established, allowing the City Council to respond more
efficiently to changing administrative costs, compliance, and enforcement needs.
Huckabee moved, seconded by Johnson perform the first reading of the ordinance and
direct the City Manager to prepare the Ordinance for a second and possible third/final
reading on October 6. Motion carried.
f. First reading of an Ordinance amending the Stormwater Utility Ordinance, Chapter 98 of
the City of Fort Atkinson Municipal Code (Navin, Director of Public Works)
Director Navin provided that on July 21, 2026 the Ordinance Committee requested that
staff evaluate an amendment to the City's Stormwater Utility Ordinance that would
remove cemetery properties from stormwater utility charges. The policy question before
the City Council is ultimately whether the unique land-use characteristics of cemeteries
warrant complete removal from the stormwater utility rate structure. While the
immediate financial effect is relatively small compared with the overall Stormwater Utility
budget, staff believes the broader policy implication is more significant. Creating a
categorical exemption establishes a precedent that may generate future requests for
similar treatment from other property types that contain substantial open or pervious
areas.
The Ordinance Committee recommends City Council perform the first reading of the
Ordinance exempting cemeteries from Stormwater Utility charges and direct the City
Manager to prepare the ordinance for a second reading at the October 6, 2026, City
Council meeting. Staff does not support this recommendation due to its negative impact
on the financial health of the Stormwater Utility.
Huckabee moved, seconded by Johnson to perform the first reading of the ordinance and
direct the City Manager to prepare the Ordinance for a second reading on October 6,
2026. Discussion continued.
Huckabee moved to amend the Stormwater Utility Ordinance Chapter 98 of the City of
Fort Atkinson Municipal Code to allow for a stormwater exemption for cemeteries with a
sunset clause of two years effective upon publication of Ordinance. Johnson seconded the
amendment. Motion carried 4-1, Jaeckel opposed.
g. First reading of an Ordinance to Amend Section 18-256 of the City of Fort Atkinson Code of
General Ordinances relating to Camping Units (Draeger, Director of Neighborhood and
Building Services)
Director Draeger commented, the City is delegated by the State of Wisconsin to
administer and enforce the Wisconsin Uniform Dwelling Code (UDC) within the City. As
part of this delegation, the City is responsible for issuing building permits, conducting
inspections, and enforcing applicable state building standards for one- and two-family
dwellings and certain related structures. The proposed ordinance amendment adopts
Page 28 of 271
Wisconsin Administrative Code SPS 327, Camping Units, by reference into Chapter 18 of
the City's Municipal Code.
Price moved, seconded by Johnson to perform the first reading of the ordinance and direct
the City Manager to prepare the Ordinance for a second and possible third/final reading
on October 6. Motion carried.
9. Reports of Officers, Boards, and Committees
a. City Manager’s Report (Houseman, City Manager)
No action was taken.
10. Unfinished Business
a. Review and possible action relating to the Affordable Housing program (Houseman, City
Manager)
Manager Houseman stated that following a Request for Proposals (RFP) process, the City
retained Redevelopment Resources to develop policies and programs for deploying excess
tax increment generated by closed Tax Increment Districts (TIDs) for an Affordable
Housing Fund. With the one year of increment in each of the TIDs mentioned, the City
estimated total revenue at $1,689,570.62. At the City Council meeting on February 17th,
the City Council adopted a Resolution allocating $250,000 of these funds to a Habitat for
Humanity Critical Repair Program. The remaining $1,439,570.62 is anticipated to be
distributed through this program over the next several years.
Price moved, seconded by Lescohier to approve the Affordable Housing Fund program and
authorize the City Manager to enter into an agreement with a qualified outside agency to
administer and facilitate program implementation. Motion carried.
11. New Business
None.
12. Miscellaneous
None.
13. Public Comment for Matters Not on the Agenda
John Hausz, 104 Jefferson Street - Wants to understand voting rights. Wants to know how
special voting deputies are handled.
Herb Bloomer, 633 Maple Street - Spoke in regard to neighbors' garbage and compliance. He
inquired on the ordinance processes.
Page 29 of 271
14. Claims, Appropriations and Contract Payments
a. Review and possible action relating to the Verified Claims presented by the Director of
Finance and authorization of payment (Ebbert, Clerk/Treasurer/Finance Director)
Huckabee moved, seconded by Johnson to approve the list of Verified Claims presented by
the Director of Finance and authorize payment. Motion carried unanimously.
15. Adjournment
Johnson moved, seconded by Price to adjourn. Meeting adjourned at 8:35 pm.
Respectfully submitted,
Michelle Ebbert
City Clerk/Treasurer/Finance Director
Page 30 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: September 15, 2026
TO: Fort Atkinson City Council
FROM: Ben Dayton, Director of Parks and Recreation
RE: Third/final reading and possible adoption of an Ordinance to amend multiple
sections of Chapter 62 of the City of Fort Atkinson Municipal Code of
Ordinances relating to park regulations (Dayton, Director of Parks and
Recreation)
BACKGROUND
Parks and Recreation Director Dayton and the Recreation Advisory Board Rules and Ordinances
Subcommittee conducted a focused review of Chapter 62, Articles I and II of the City’s Codes
and Ordinances. Additionally, the subcommittee investigated the addition of a new ordinance
to prohibit the use of smoking, vaping, and e-cigarettes products within the City's park system.
The City Council performed the first reading at the meeting on August 18th. After a proposed
amendment to change the areas where smoking would be prohibited in parks failed, the
motion to direct the City Manager to prepare the ordinance for a second reading carried. The
second reading was held September 1.
DISCUSSION
Staff provided the subcommittee with a proposal adopting new ordinance to prohibit smoking,
vaping, and the use of e-cigarettes within city parks and on public trails. Additionally, revisions
were recommended to existing ordinances regarding pets on designated park property,
protection of City property within the parks system, glass bottle restrictions, and park hours of
operation. These amendments are intended to align current usage of park facilities with City
ordinance.
The following recommendations and rationales are proposed:
ARTICLE I. - IN GENERAL
Sec. 62-1. - Animals on city park grounds:
Staff proposes extending this ordinance to include designated athletic fields and playgrounds.
This restriction is intended to prevent damage to prepared ballfields and ensure playgrounds
remain free of animal waste. Also, extending the ordinance to easily recognizable facilities
without the need for additional posted signage.
Page 31 of 271
Sec. 62-2. - Operation of vehicles, animals restricted; destruction of property.
Staff recommends adding language to specifically identify the unauthorized tampering with city
property during activities such as geocaching and the use of metal detectors. While geocaching
is recognized as an acceptable activity, the intent is to prevent the modification of or damage to
facilities and property.
Sec. 62-4. - Possession, consumption of alcohol prohibited.
Staff recommendations include removing the prohibition of alcohol consumption in
Bicentennial Park. The original ordinance was adopted when the park was located in a different
area. Memorial Park will remain on the list due to its primary use as a youth sports facility. The
ordinance will also be updated to include legal, hemp-derived THC beverage products and a
citywide prohibition of glass bottles in parks to enhance public safety and reduce the risk of
injury from broken glass.
Sec. 62-5. - Smoking, vaping, and e-cigarettes prohibited. (proposed new ordinance)
Staff recommends, with subcommittee support, the adoption of a new ordinance prohibiting
the use of smoke or vapor producing products within park spaces. Aside from public health
concerns, the intent is to remove smoking and vaping from public events, youth activities, and
locations where the general public will congregate. Under the proposed rules, the use of these
products would be restricted to areas within the public right-of-way.
ARTICLE II. - ADMINISTRATION AND ENFORCEMENT
Sec. 62-37. - Hours of operation.
Staff recommends that park hours mirror the weekend hours established by the citywide
curfew ordinance (Section 58-197). This update also includes the removal of specific, outdated
hours previously set for Bicentennial Park.
FINANCIAL ANALYSIS
Staff does not anticipate a significant financial impact associated with the recommended new
ordinance and ordinance amendments.
RECOMMENDATION
Staff, the Parks and Recreation Advisory Board, and the Ordinance Committee recommended
the City Council adopt the Ordinance amendments to Chapter 62 relating to park regulations as
proposed.
ATTACHMENTS
1. Chapter_62___PARKS_AND_RECREATION
2. Ord No Parks and Recreation Section 62 DRAFT REDLINE
3. Ord No Parks and Recreation Section 62 FINAL
Page 32 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
PLAN COMMISSION MEETING
IN PERSON AND VIA ZOOM
TUESDAY, SEPTEMBER 22, 2026 – 4:00 PM
CITY HALL – SECOND FLOOR
MINUTES
1. Call meeting to order
Chairperson Manager Houseman called the meeting to order at 4:00 pm.
2. Roll call
Present: Chairperson Manager Houseman, Director of Public Works Navin, Commissioners
Ciccarelli, Shull, and Schultz. Also present: Director of Neighborhood and Building Services,
Clerk/Treasurer/Finance Director, Deputy Clerk, and City Attorney.
Excused Absent: Council Representative Huckabee
3. New Business
a. Review and possible action relating to the minutes of the August 25, 2026, Plan
Commission meeting (Ebbert, Clerk/Treasurer/Finance Director)
Schultz moved, seconded by Ciccarelli, to approve the minutes of the August 25, 2026 Plan
Commission meeting. The motion carried, 5-0.
b. Review and possible action relating to a Site Plan Review for the property located at 815
Jefferson St. (226-0614-3432 and 226-0614-3432-004) (SPR-2026-12) (Draeger, Director of
Neighborhood and Building Services)
Director Draeger presented the Site Plan Review for the property located at 815 Jefferson
St. Opportunities Inc. is proposing an outdoor activity area for its employees at its
commercial campus on the north side of Fort Atkinson. The property was recently
approved for a Certified Survey Map (CSM) combining two lots into a new 3.2-acre site
with frontage on Jefferson Street, E. Cramer Street, and Clarence Street. The site currently
includes two structures, on-site parking, and an east-west internal driveway connecting
Jefferson Street and Clarence Street. The proposed project would be located on the
southern portion of the site and include a new outdoor recreational area, off-street
parking on either side, and reuse of the existing structure.
Ciccarelli motioned, seconded by Schultz to recommend approval of the Site Plan, subject
to the following conditions:
Page 33 of 271
• Require the applicant to provide the following information that meets all the
requirements of the Zoning Code to be reviewed by City staff:
o Add curbing to meet the minimum requirements
o Add on-site bicycle parking to meet the minimum requirements
o Provide a trash enclosure plan compliant with Section 15.06.21
o Provide the location of building mechanicals and screening if necessary
o Execute a Stormwater Management Agreement with the City
• Waive the requirement for any loading areas to be located outside the front yard
setback (the existing building on the south end of the site is not proposed to
change and is currently located approximately 25 feet from the property line,
creating limited space to accommodate the proposed new loading area outside
that setback).
• Approve the new access point from Clarence street as proposed
• Require the recording of the previously approved CSM
• Any other recommendations of City staff and the Plan Commission.
Ciccarelli discussed the need for pedestrian path connectivity from the city sidewalk on
Jefferson Street into the playground park and the building in front of the playground. He
also addressed the Clarence side parking lot and the possibility of pedestrian connectivity
from the parking lot to get into and out of the playground. Director Navin stated that the
intended primary parking lot for the playground is the Jefferson Street lot.
Ciccarelli moved, seconded by Shull to amend the motion to include the following
condition of a pedestrian sidewalk and striping on the south-eastern portion of the site
plan to connect the city sidewalk to the concrete sidewalk in front of the building. Motion
carried, 5-0.
Chairperson Manager Houseman called for a vote on the underlying motion to
recommend approval of the Site Plan with the original and amended conditions. Original
Motion carried, 5-0.
c. Update on previously approved projects (Houseman)
Chairperson Manager Houseman provided the following updates:
• The Plan Commission recommended that the City Council approve an offer to
purchase Lot 1 of Klement Business Park. The City Council approved the offer, and
staff is currently working with the property owner on site plans prior to closing.
• After receiving Plan Commission approval at various stages, e.g. zoning, site plan
review, Certified Survey Maps (CSMs), and conditional use permits. All three
projects, River Trail Flats, Cardinal View Crossing, and River Point Commons, have
approved and executed development agreements, with construction anticipated to
begin this fall.
Page 34 of 271
4. Adjournment
Schultz moved, seconded by Ciccarelli to adjourn. Meeting adjourned at 4:26 p.m.
Respectfully submitted,
Courtney Thom
Deputy Clerk
Page 35 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Fort Atkinson City Council
FROM: Michelle Ebbert, Clerk/Treasurer/Finance Director
RE: Review and possible recommendation relating to Alcohol Beverage License
Agent Change DLM Group LLC, dba Jennies Entertainment Center, 1245
Whitewater Avenue (Ebbert, Clerk/Treasurer/Finance Director)
BACKGROUND
The State of Wisconsin regulates alcohol licensing for local governments through Chapter 125.
Alcohol Licenses issued to Limited Liability Companies must appoint an agent to operate the
business. Agent responsibilities per Statute are listed below:
(6) Licenses to corporations and limited liability companies; appointment of agents.
125.04(6)(a)(a) Agent. No corporation or limited liability company organized under the laws of
this state or of any other state or foreign country may be issued any alcohol beverage license or
permit unless:
125.04(6)(a)1. 1. The entity first appoints an agent in the manner prescribed by the authority
issuing the license or permit. In addition to the qualifications under sub. (5), the agent must,
with respect to character, record and reputation, be satisfactory to the issuing authority.
125.04(6)(a)2. 2. The entity vests in the agent, by properly authorized and executed written
delegation, full authority and control of the premises described in the license or permit of the
entity, and of the conduct of all business on the premises relative to alcohol beverages, that the
licensee or permittee could have and exercise if it were a natural person.
125.04(6)(b) (b) Successor agent. A corporation or limited liability company may cancel the
appointment of an agent and appoint a successor agent to act in the agent's place, for the
remainder of the license year or until another agent is appointed, as follows:
125.04(6)(b)1. 1. The successor agent shall meet the same qualifications required of the first
appointed agent.
125.04(6)(b)2. 2. The entity shall immediately notify the issuing authority, in writing, of the
appointment of the successor agent and the reason for the cancellation and new appointment.
125.04(6)(c) (c) Authority of successor. A successor agent shall have all the authority, perform
all the functions and be charged with all the duties of the previous agent of the corporation or
limited liability company until the next regular or special meeting of the issuing authority if a
license is held. However, the license of the corporation or limited liability company shall cease to
be in force if, prior to the next regular or special meeting of the issuing authority, the clerk of the
licensing authority receives notice of disapproval of the successor agent by a peace officer of the
Page 36 of 271
municipality issuing the license.
DISCUSSION
DLM Group, LLC dba Jennie's Entertainment Center, located at 1245 Whitewater Avenue, has
submitted a request for an agent change. Agents for licensed establishments manage many
aspects of a business including scheduling, hiring, ordering of product, and managing finances.
A background check was performed on the applicant without concerns.
Per State Statute, 125.04(5)(a)(2) Individuals, all natural persons in a partnership and the agents
of corporations and limited liability companies are subject to 90 day continuous residency in
this state prior to the date of application. The prior agent had since moved out of Wisconsin,
therefore requiring the assignment of a new agent.
FINANCIAL ANALYSIS
There is a $10 fee associated with an agent change.
RECOMMENDATION
The License Committee reviewed this Agenda item at their September 15, 2026 meeting and
recommended Council approval. Staff recommends that City Council approve the agent change
for DLM Group, LLC dba Jennie's Entertainment Center at 1425 Whitewater Avenue for the
licensing period of October 7, 2026 through June 30, 2027.
ATTACHMENTS
1. DLM Group Agent Appointment Romie Johnson_Redacted
Page 37 of 271
Form
AB-101
Agent Type (check one)
Alcohol Beverage
Appointment of Agent
D Original (no fee) 0 Successor ($1 O fee for municipal licensees only)
Part A: Bllsiness Information
1. Legal Business Name (Individual name if sole proprietor)
DLM Group LLC
2. Business Trade Name or DBA
Jennies Entertainment
--- -- -
Center
3. Entity Type (check one)
0 Limited Liability Company D Corporation
I Date
07/15/2026
D Nonprofit Organization
4. Alcohol Beverage Business Authorization (check one)
15. If successor agent, provide State Permit or Municipal Retail License Number
0 Municipal Retail License D State Permit
6. Describe the reason for appointing a successor agent, if successor is checked above.
Orginal Agent no longer
Part B: Agent Information
1. Last Name
Johnson
4. Email
6.H
7. City
Wisconsin Resident
1
2_. First Name
Romie
18. State
1
9. Zip Code
WI
I3.M.I.
J
15. Phone
110. Date of Birth
11. ense/State ID Number
1
ver's License/State ID State
- 0 WI
Part C: Agent Questions
1. Have you satisfied the responsible beverage server training requirement? ... '.' ................. ' ... � Yes ONo
Submit proof of completion. I
2. Have you completed Form AB-100, Alcohol Beverage Individual Questionnaire (licensee) or
� Yes □ No Form AB-300, Alcohol Beverage Personal Questionnaire (permittee)? '.' .. ' .' ... ' .. ' ......... '. ' .. '.
3. Have you been a Wisconsin resident for at least 90 continuous days? ................................ � Yes □ No
See instructions for exceptions.
Continued�
AB-101 (R. 2-26) - 1 - Wisconsin Department of Revenue
Page 38 of 271
Page 39 of 271
Form
AB-1O0
Alcohol Beverage
Individual Questionnaire
All individuals involved in the alcohol beve rage business must complete this form, including:
I Date
• sole proprietor • all officers, directors, and agent of a corporation or nonprofit organization
• all partners of a partnership • members and agent of a limited liabilit y company
Your alcohol beverage application is not complete until all required Individual Questionnaires are submitted.
Part A: Business Information
1. Legal Business Name (individual name if sole proprietor)
OLM Group LLC
-2, BusinessTrade Name or OBA
Jennie's Entertainment and Events
3. Entity Type (check one)
D Sole Proprietor D Partnership
Part B: Individual Information
1. Last Name
Johnson
4. Relationship to Business (Title)
Majority Owner
7. Home Address
8. City
----- --
� Limited Liability Company
1 2. First Name
Romie
D Corporation
1
1
9. State 10. Zip Code
WI
'
D Nonprofit Organization
13
. M.
I
.
1
6. Phone
1 11. Date of Birth
12. Driver's License/State ID Number 13. Driver's License/State
I
D State of Issuance
WI
Part C: Address History
1.
Do you currently live in Wisconsin? ............................................................ � Yes 0 No
If yes, provide the month and year when you permanently moved to Wisconsin .......... ' .......... ' ... l
(MM/YYYY)
06/2024
2. List in chronological order all of your addresses within the last 5 years. Attach additional sheets if necessary.
Previous Address 1 City State Zip Code
IL
Previous Address 2 City State Zip Code
Previous Address 3 City State Zip Code
Previous Address 4 City State Zip Code
Previous Address 5 City State Zip Code
3. List all states
and counties you have lived in as an adult. Attach additional sheets if necessary.
State County State County State County State County
State County State County State County State County
Continued�
AB-100 (R. 2-26) - 1 - Wisconsin Department of Revenue
Page 40 of 271
Pirf Pf PifQ'i:1�;1/t{t
1. Have you ever been convicted of any offenses (excluding traffic offenses unless related to alcohol beverages)
for violation of any federal, Wisconsin, or another state's laws or of any county or municipal ordinances?. . . . . . D Yes � No
If yes to question 1, please list details of each conviction below. Attach additional sheets as needed .
Law/Ordinance Violated
Penalty Imposed
Law/Ordinance Violated
Penalty Imposed
Law/Ordinance Violated
Penalty Imposed
Location
Location
Location
Conviction Date
Was sentence completed? . . . . . D Yes D No
Conviction Date
Was sentence completed? . . . . . D Yes D No
Conviction Date
Was sentence completed?. . . . . D Yes D No
2. Are charges for any offenses currently pending against you (excluding traffic offenses unless related to alcohol
beverages) for violation of any federal, Wisconsin, or another state's laws or any county or municipal
ordinances?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Yes � No
If yes to question 2, describe nature and status of pending charges using the space below. Attach additional
sheets as needed.
Part E: Attestation
READ CAREFULLY BEFORE SIGNING: Under penalty of law, I have answered each of the above questions completely and
truthfully. I certify that I am not prohibited from participating in this business due to any involvement in another tier of the alcohol
beverage industry as a restricted investor. I understand that any license issued contrary to Wis. Stat. Chapter 125 shall be void
under penalty of state law. I further understand that I may be prosecuted for submitting false statements and affidavits in connection
with this application, and that any person who knowingly provides materially false information on this application may be required
to forfeit not more than $1,000 if convicted .
Signature Date
8/11/26
AB-100 (R. 1-25) - 2 -
Page 41 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Fort Atkinson City Council
FROM: Michelle Ebbert, Clerk/Treasurer/Finance Director
RE: Review and possible recommendation relating to Alcohol Beverage License
Name Change ("DBA" Change) for Creamery 201, LLC dba Vallarta Bar and Grill,
LLC at 201 N. Main Street (Ebbert, Clerk/Treasurer/Finance Director)
BACKGROUND
The State of Wisconsin regulates alcohol licensing for local governments through Chapter 125.
Local governments are given the authority to issue licenses where alcohol is consumed in a
public place in accordance with requirements set forth by Statute. There are three classes of
Licenses: Class A, Class B, and Class C. “Class C” pertains strictly to wine with consumption on-
site in a restaurant. The difference between Class A and B is where alcohol is authorized for sale
and for consumption. Class A generally offers sale of alcohol on-site with consumption off-site
(e.g. grocery or liquor store, gas station or convenience store). Class B allows for on-site sale
and on-site consumption (e.g. Restaurant, Bar, Bowling Alley, Tavern). Class A can easily be
remembered as you consume alcohol Away from the premises. Likewise, Class B you consume
on-site, for example Bar.
DISCUSSION
Creamery, 201 LLC has submitted a request to change the DBA (doing business as) for their
location at 201 N. Main Street Ste. 220. Creamery 201 has a "Class B" Intoxicating Liquor and
Class "B" Fermented Malt Beverage license. The request is to operate as Vallarta Bar and Grill
at said location. There is no change to the premises description and is as provided: Second floor
of 201 N Main Street, hallways and outdoor enclosed area, Suite 220 and outdoor seating area.
The premise includes the event venue and the attached restaurant with outdoor patio.
FINANCIAL ANALYSIS
There are no fees associated with a DBA change.
RECOMMENDATION
The License Committee reviewed this item at their September 15, 2026 meeting and
recommended Council approval. Staff recommends the City Council to approve the dba change
for Creamery 201, LLC to dba Vallarta Bar and Grill, LLC for use at 201 N. Main Street Ste 220 for
Page 42 of 271
the licensing period of October 7, 2026 through June 30, 2027.
ATTACHMENTS
1. Creamery 201 - Vallarta Bar and Grill 09042026
Page 43 of 271
August 25, 2026
To: City of Fort Atkinson
License Committee
City Council
Statement of Business Plan:
License to be listed to: Creamery 201, LLC / Suite 201
DBA: Vallarta Bar and Grill, LLC / Suite 220
Premise Description:
Second floor of 201 N Main Street, hallways and outdoor enclosed area, Suite 220
and outdoor seating area.
Katie Stahl, Agent
Creamery 202, LLC
Page 44 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Fort Atkinson City Council
FROM: Minetta Lippert, Library Director
RE: Review and possible action relating to the installation of assistive listening
technology in Dwight Foster Public Library's FCCU Community Room (Lippert,
Library Director)
BACKGROUND
Bridges Library System budgeted $13,000 to install a hearing loop at the Dwight Foster Public
Library in 2026.
Hearing loops and Auracast systems empower hearing aid wearers to directly connect to the
sound going into a microphone. This ensures that the featured sounds are clear and not
overpowered by background noise. The system would also come with portable receivers that
individual attendees could wear. Hearing loops are a proven technology with decades of global
use; Auracast is an up-and-coming technology. Several vendors anticipate that Auracast will
fully replace hearing loops in about 10 years.
DISCUSSION
Library staff consulted with other libraries that have installed assistive listening technology.
Based on the recommendations of staff members at other libraries, library staff sought
proposals from DRS Sound, Metro Sound & Video, and Thunder Hearing & Sound. Dave from
DRS Sound declined submitting a proposal due to travel distance but instead recommended
that library staff reach out to Dave Harmon. Library staff received proposals from Dave Harmon,
Metro Sound & Video, and Thunder Hearing & Sound.
Option 1: Dave Harmon
Equipment and Installation Cost: $4,800
Notes: Proposal does not include Auracast. The vendor did not visit the site nor did the vendor
conduct metal loss testing in advance of submitting a proposal. Installation of the hearing loop
wire would be below the carpet tiles in the library's FCCU Community Room.
Option 2: Metro Sound & Video
Equipment and Installation Cost: $13,746 ($6,672 for Auracast and $7,074 for the loop system)
Notes: Proposal includes both Auracast and a hearing loop. The vendor visited the site but did
Page 45 of 271
not conduct metal loss testing in advance of submitting a proposal. Installation of the hearing
loop wire would be above the ceiling tiles in the library's FCCU Community Room.
Option 3: Thunder Hearing & Sound
Equipment and Installation Cost: $12,060.60 (for both Auracast and the loop system, including
an Auracast early adopter discount)
Notes: Proposal includes both Auracast and a hearing loop. The vendor visited the site,
conducted metal loss testing, and led a demonstration of the technology for staff. Installation
of the hearing loop wire would be above the ceiling tiles in the library's FCCU Community
Room.
After evaluating the three proposals, library staff recommend pursuing Thunder Hearing &
Sound's proposal due to the overall cost and the scope of the proposal. Even though Dave
Harmon's proposal costs less than the other two options, Harmon's proposal involves installing
the loop under the carpet tiles, an installation method that staff do not prefer, and does not
include Auracast.
FINANCIAL ANALYSIS
Thunder Hearing & Sound proposes to install a hearing loop and Auracast in the FCCU
Community Room at the Dwight Foster Public Library for $12,060.60. Library staff did not
budget for assistive listening technology installation in 2026. However, Bridges Library System
budgeted $13,000 to install a hearing loop at the Dwight Foster Public Library in 2026. Bridges
Library System staff are supportive of installing Auracast in addition to installing a hearing loop.
If the Dwight Foster Public Library moves forward with the installation of assistive listening
technology, library staff will submit the invoice to Bridges Library System for full reimbursement
up to $13,000.
Both Metro Sound & Video and Thunder Hearing & Sound expect that future maintenance costs
for a hearing loop and/or an Auracast system will be minimal for the expected lifespan of the
system(s).
On Monday, September 14, 2026, the Dwight Foster Public Library Board of Trustees approved
accepting the proposal from Thunder Hearing & Sound to install a hearing loop and Auracast
system at the library for the cost of $12,060.60. Wis. Stat. § 43.58(1) states, “The library board
shall have exclusive control of the expenditure of all moneys collected, donated, or
appropriated for the library fund.” In general practice, this means that once revenues (levied by
the City, donated, or allocated by the County) are put into the library fund, the Library Board
has exclusive control over the associated expenditures. The City’s Financial Stability Guidelines
indicate that purchases over a certain threshold must be approved by the City Council. While
library expenditures are generally outside the purview of the City Council, staff are bringing this
proposal to City Council for review to follow the City’s financial policy. Staff also recognize that
the proposed funding source for this project will be reimbursement from Bridges Library
System, not funds already appropriated for or donated to the library fund.
Page 46 of 271
This item was budgeted by Bridges Library System and has been approved by the Dwight Foster
Public Library Board of Trustees, which is why it has been placed on the Consent Agenda for
final City Council approval following recent practice.
RECOMMENDATION
Staff recommends approving Thunder Hearing & Sound's assistive technology proposal to install
a hearing loop and Auracast in the FCCU Community Room at the Dwight Foster Public Library
for $12,060.60.
ATTACHMENTS
1. Dave Harmon Fort Atkinson Hearing Loop estimate 00646
2. Metro Sound Assistive Listening System Proposal - Dwight Foster Public Library (Fort
Atkinson, WI) - August 2026 P-1711 Assistive Listening System Pro
3. Thunder Hearing Assistive Technology Proposal - UPDATED 8-2026
Page 47 of 271
Crafted with ease using
Visit to create truly professional invoiceszoho.com/invoice
1
Sub Total 4,800.00
Total $4,800.00
Estimate Date : 07/17/26
David Harmon
David Harmon
922 Prague Ave
Buffalo Grove IL 60089
U.S.A
ESTIMATE
# EST-00646
Bill To
Dwight Foster Public Library
209 Merchants Ave.
Fort Atkinson
53538 Wisconsin
U.S.A
# Item & Description Qty Rate Amount
1 Hearing loop installation, all in. Including : New hearing loop
driver, wall mount rack, probably a ceiling mounted mic,
probably flat copper tape wiring under the carpet. Any wiring
or related integration needed to tap into the sound system. A
5 year warranty of the driver, materials and workmansip. A
hearing loop receiver so someone can listen in to test that it
works or could be used by a user who needs it but doesn't
have hearing aids. A sign letting people know that a hearing
loop is present and available. As a Library, this is tax-exempt.
1.00 4,800.00 4,800.00
Notes
Looking forward for your business.
Page 48 of 271
Metro Sound & Video
www.metro-sound.com
Assistive Listening System Proposal
Dwight Foster Public Library (Fort Atkinson, WI)
209 Merchants AvenueFort Atkinson, Wisconsin 53538United States
Presented By
Metro Sound & Video
Presented On
Aug 17, 2026
Version
1
1 7 0 2 8 W e s t V i c t o r R o a d
N e w B e r l i n , W i s c o n s i n 5 3 1 5 1
U n i t e d S t a t e s
br e n n a@ m e t r o- s ou n d. c om
( 2 6 2 ) 7 8 4 - 6 0 6 0
B r e n n a P o l l a k
br e n n a@ m e t r o- s ou n d. c om
08/17/2026 Assistive Listening System Proposal V1 Page 1 of 12
Page 49 of 271
Disclosure
The enclosed system design and proposal remains the property of Metro Sound & Video. It is proprietary information
obtained from our years of experience and expertise in the design, installation, and service of audio and video
systems. The information contained herein may not be duplicated or distributed by anyone without written permission
from Metro Sound & Video.
Introduction
Hello Minetta,
I enjoyed meeting with you to discuss the Assistive Listening System (ALS) needs at Dwight Foster Public Library.
Based on our discussion, enclosed is the Assistive Listening System Proposal that you requested.
As discussed during our meeting at the library, we are pleased to offer two options for Assisted Listening in the FCCU
Community Room. Our recommended solution is an Auracast™ system utilizing the latest Bluetooth Low Energy
technology, supporting both Auracast-enabled hearing devices and users requiring bodypack receivers with either
headphones or neckloop accessories. Alternatively, a basic perimeter Inductive Loop System is offered to support
telecoil-equipped hearing aids and users requiring bodypack receivers with headphones. Both options include
equipment, installation, system configuration, and operator training - all detailed below for your review.
After you have had an opportunity to review the system proposal, please let me know if you have any questions or if
you would like any revisions made to better suit your needs. If you wish to proceed with one or both options, we would
be happy to assist!
Thank you Minetta, for the opportunity to work with you in serving the audiovisual system needs at Dwight Foster
Public Library!
Blessings on your day,
Brenna Pollak
System Description
As discussed during our meeting at the library, Metro Sound & Video is pleased to offer two Assistive Listening System
options for the FCCU Community Room. Our recommended solution is the Williams AV Auracast™ system, which
provides the greatest flexibility for serving users with a variety of hearing devices and listening needs. Alternatively, a
traditional perimeter Inductive Loop System is offered as a cost-effective solution for users with telecoil-equipped
hearing aids.
Both options utilize the existing Peavey PVi4B powered mixer as the audio source and include the necessary
equipment, installation, system configuration, and operator training.
Option 1 – Williams AV Auracast™ Assistive Listening System
08/17/2026 Assistive Listening System Proposal V1 Page 2 of 12
Page 50 of 271
Metro Sound & Video recommends a Williams AV Auracast™ system as
the most flexible solution for the FCCU Community Room. Auracast™ is
the latest generation of assisted listening technology, utilizing
Bluetooth® Low Energy to transmit high-quality audio directly to
compatible hearing devices and receivers.
The proposed system provides multiple ways for users to access the
assisted listening signal. Users with Auracast™-enabled hearing
devices can connect directly to the broadcast, while users with
telecoil-equipped hearing aids can utilize a neckloop accessory
connected to a bodypack receiver. For users who do not have
compatible hearing devices, a bodypack with headphones provides an independent listening solution.
The proposed system includes:
The Auracast™ transmitter will be located on top of the existing cart where the Peavey mixer is currently located.
Depending on the final performance of the wireless signal within the room, it may be necessary to remotely locate
the Auracast™ antenna. If required, additional Wiremold® and associated installation labor will be provided on a
time-and-materials basis.
The assistive listening system (ALS) will receive its audio signal from the existing Peavey PVi4B analog powered mixer
currently located on the portable cart in the Community Room. We have assumed that the existing mixer is
functioning properly and has an available output that can be used to feed the ALS. That being said, we strongly
recommend replacing the existing mixer with a more reliable and capable audio processor at the appropriate time in
the future. This would provide a more clean and reliable audio signal to the ALS while also providing a more suitable
and capable solution for the Community Room's overall audio needs.
The Peavey mixer is currently used on an occasional basis when connected to the standalone loudspeaker in the
room. In order for the assistive listening system to receive the appropriate audio signal, presenters will need to use the
existing wired handheld microphone connected to the Peavey mixer. Because the Peavey mixer will remain the
primary audio source, the overall audio quality of the ALS will be limited by the performance and condition of this
existing equipment. No replacement or upgrade of the existing mixer is included in this proposal.
Option 2 – Williams AV DL107 Inductive Loop System
As an alternative to Auracast system, Metro Sound &
Video can provide a traditional perimeter Inductive Loop
System utilizing the Williams AV DL107 Loop Amplifier. This
system is designed primarily for users with telecoil-
equipped hearing aids or cochlear implants and provides coverage throughout the Community Room through a
single closed-loop conductor.
The proposed perimeter loop will be installed above the existing drop-tile ceiling and configured as a closed loop,
allowing the audio signal to emanate downward throughout the listening area. This provides a clean and unobtrusive
installation while allowing users with compatible telecoil-equipped devices to receive the assistive listening signal
without requiring a separate receiver.
Williams AV Auracast™ transmitter system•
(6) bodypack receivers•
(6) headphone/neckloop accessory sets, allowing each user to select the accessory best suited to their needs•
Charging bay for the bodypack receivers•
Installation, configuration, and testing•
Operator training•
08/17/2026 Assistive Listening System Proposal V1 Page 3 of 12
Page 51 of 271
For users who do not have a telecoil-equipped hearing device,
the system will also include (6) bodypack receivers with
headphones, providing an alternative method of accessing the
signal.
The proposed system includes:
The DL107 loop amplifier will be installed in a wall-mounted rack, with the final location to be determined during
installation. A location behind the existing television is anticipated, subject to field conditions and final approval.
As with Option 1, the existing Peavey PVi4B analog powered mixer will be used as the audio source for the Inductive
Loop System. We have assumed that the mixer is functioning properly and has an available output suitable for
connection to the loop amplifier.
The current portable cart arrangement is not ideal for the permanent loop installation. As part of this option, the
Peavey mixer should be relocated to a fixed location rather than remaining on the portable cart. A dedicated
interconnection, or "umbilical," will be installed between the mixer and the loop amplifier, including an appropriate
disconnect to allow the system to be properly serviced or disconnected if needed.
The connection between the Peavey mixer and the wall-mounted loop amplifier will require a portion of wiremold or
similar surface raceway. The final routing and quantity will be determined based on the approved equipment
locations and actual field conditions.
As with the Auracast™ option, the existing Peavey mixer is the audio source for the system, and the overall audio
quality will be limited by the performance and condition of this existing equipment. Presenters will need to use the
existing wired handheld microphone connected to the Peavey mixer in order for the ALS to receive the appropriate
audio signal.
Recommendation
Of the two options presented, Metro Sound & Video recommends the Williams AV Auracast™ system. Its ability to
serve users with Auracast™-enabled hearing devices, telecoil-equipped hearing aids through a neckloop, and users
without compatible hearing devices through bodypack/headphone receivers makes it the most flexible solution for
the FCCU Community Room.
Both systems will provide an effective assistive listening solution, and we would be happy to proceed with whichever
option best fits FCCU's needs and budget. Thank you again for the opportunity to work with you on this project!
Scope of Work
Williams AV DL107 Inductive Loop Amplifier•
Single perimeter closed-loop system installed above the drop-tile ceiling•
(6) bodypack receivers with headphones•
Wall-mounted equipment rack for the loop amplifier•
Installation, configuration, and testing•
Operator training•
MSV shall provide and install all AV system hardware required to achieve the AV system goals described herein
(see product list below).
•
08/17/2026 Assistive Listening System Proposal V1 Page 4 of 12
Page 52 of 271
Exclusions; Client Responsibilities & Infrastructure
Requirements
Electrical Requirements
Internet Service Provider Requirements
Architectural Requirements & Considerations
MSV shall provide, install, dress, terminate and test all low voltage wire required to properly connect all AV
system hardware included herein.
•
MSV shall configure, program, and optimize all AV system hardware included herein.•
Upon project completion; MSV shall coordinate with client to provide a thorough in-person operator training
session on all applicable systems described herein.
•
Please note: The included operator training session is to take place during normal business hours (9am-
5pm Mon.-Fri.). Additional fees apply for after-hours requests.
•
Metro Sound & Video provides low voltage AV electronics integration only. This proposal does not include
electrical labor or materials of any kind. The Dwight Foster Public Library shall be responsible for contracting a
licensed third party electrician to perform all required electrical work described herein, including:
•
Providing adequate electrical service at the ALS transmitter location. A standard 120V duplex AC outlet
will be sufficient.
•
The Dwight Foster Public Library shall coordinate with its service provider to provide a wired LAN connection
with active internet connectivity at the ALS transmitter location.
•
Metro Sound & Video recommends that the Library consider permanently mounting the existing Peavey
powered mixer, or better yet replacing it with a more capable audio processor or mixer/amplifier that can
better support the current setup and accommodate future audio improvements. This is not included in the
scope of work in this proposal, but we can revise to accommodate those recommendations if desired.
•
08/17/2026 Assistive Listening System Proposal V1 Page 5 of 12
Page 53 of 271
General Information
Metro Sound and Video is a full-service design/build contracting firm that has proudly served thousands of Houses of
Worship, businesses, and schools to date. We maintain complete capability to provide design, installation, service
and support for all audio, video and acoustic systems.
All Metro Sound and Video systems are installed by our own technicians to exacting standards. This proposal includes
all labor, low-voltage wiring, hardware, and connectors necessary to provide a complete, functioning system.
Metro Sound & Video provides low voltage AV electronics integration only. This proposal does not include electrical
work of any kind. The Dwight Foster Public Library is responsible for providing clean AC power to the AV system
electronics as described herein.
This system design and proposal remains the property of Metro Sound & Video. It is proprietary information obtained
from our years of experience and expertise in the design, installation, and service of audio and video systems. The
information contained herein may not be duplicated or distributed by anyone without written permission from Metro
Sound & Video.
Warranty Details
We provide a guarantee against defective new equipment and workmanship for a period of one year from the
installation date.
This guarantee covers the newly installed low-voltage materials, labor for service, and travel time.
This warranty does not include:
Repair costs necessary for existing equipment not provided with the system upgrade.
Repair of damage caused by misuse/misadjustments, abuse, or other acts of God.
Any return visits required for additional training and/or adjustments to the system. Additional training
session(s) and/or system level adjustment(s) following the installation and provided training session will be
invoiced at our standard rate.
08/17/2026 Assistive Listening System Proposal V1 Page 6 of 12
Page 54 of 271
Equipment List
Auracast Assistive Listening System OPTIONAL
Not Added to Quote
Note: This is a client-selectable option. If you wish to proceed with this, please click "Add to Quote" (prior to digitally
accepting the proposal), and total pricing will be automatically updated at the bottom of this document.
Williams AV 1
Infinium System | 4 Receivers Includes BA CT1 package plus
Williams AV 2
Infinium Receiver Multi-channel Auracast receiver with a high-resolution OLED
screen
Williams AV 2
Folding Headphones (Stereo)
Williams AV 4
Neckloop 18" for earphone
+ $6,672.00
I T E M Q T Y
08/17/2026 Assistive Listening System Proposal V1 Page 7 of 12
Page 55 of 271
Windy City Wire 1
23 AWG 4 Pair Bare Copper, Non-Shielded Non-Plenum Rated Category 6
[Black]
Shipping/Freight Charges 1
Technician Time for Installation 1
Technician Labor for System Installation
System Configuration and Setup 1
System Configuration, Setup, and Miscellaneous Programming
Operator Training Session 1
08/17/2026 Assistive Listening System Proposal V1 Page 8 of 12
Page 56 of 271
Technician Travel Time 1
Inductive Loop System OPTIONAL
Not Added to Quote
Note: This is a client-selectable option. If you wish to proceed with this, please click "Add to Quote" (prior to digitally
accepting the proposal), and total pricing will be automatically updated at the bottom of this document.
Williams AV 1
Digi-Loop DSP single channel loop amplifier
Windy City Wire 1
14 AWG 2 Conductor Bare Copper, Non-Shielded Non-Plenum UL Listed (UL)
CL3R [Black]
Williams AV 6
Proloop body pack induction loop receiver
+ $7,074.00
I T E M Q T Y
08/17/2026 Assistive Listening System Proposal V1 Page 9 of 12
Page 57 of 271
Williams AV 6
Folding Headphones (Stereo)
Williams AV 3
Charger kit for body-packs, 2-bay
Williams AV 1
ADA Wall Plaque (T-Coil)
Strong 1
Strong Vertical Wall Mount Rack
Furman 1
15A Standard Power Conditioner
Metro Sound & Video 1
Miscellaneous Hardware, Connectors, Termination Blocks, etc.
Metro Sound & Video 1
Miscellaneous Wiremold, Conduit, Split Loom. Cabling, Hardware, and Supplies
08/17/2026 Assistive Listening System Proposal V1 Page 10 of 12
Page 58 of 271
Shipping/Freight Charges 1
Technician Time for Installation 1
Technician Labor for System Installation
System Configuration and Setup 1
System Configuration, Setup, and Miscellaneous Programming
Operator Training Session 1
Technician Travel Time 1
Summary
Total Price $0.00
08/17/2026 Assistive Listening System Proposal V1 Page 11 of 12
Page 59 of 271
Tariff/Pricing Disclaimer
Tariff Disclaimer: The prices quoted in this proposal are subject to change upon fluctuating tariffs applied to new
equipment orders. Should any tariff charges be assessed to the quoted equipment orders for your system, the exact
amount will be added onto the project balance and will be reflected on the final invoice for payment by the client.
Due to the recent pricing increases assessed by various manufacturers, equipment prices quoted in this proposal are
valid for 30 days beyond the proposal date. Following that 30 days, a revised proposal will be provided to reflect
current prices.
Payment Schedule Amount
- 50% Deposit due upon proposal acceptance (required for equipment procurement)
- Progress invoices may be issued for equipment ordered and work completed to date as the project
requires
- Remaining Balance due upon completion of the project
Please contact Metro Sound & Video prior to acceptance to discuss approximate timeframe for Installation,
which we hope to be within 90-120 days after the down payment is received. Due to potential unforeseen
shipping delays and backordered equipment that is out of our control, this may fluctuate.
We truly appreciate the opportunity to serve you with your AV system needs!
Deposit (50%)
Upon Completion (50%)
Signature
Signature Date
$ 0 . 0 0
$ 0 . 0 0
08/17/2026 Assistive Listening System Proposal V1 Page 12 of 12
Page 60 of 271
Assistive Technology Proposal for
Dwight Foster Public Library
Fort Atkinson, WI
_________________________________
This proposal contains all details relevant to scope of work, pricing, and
terms as requested by Dwight Foster Public Library Fort Atkinson, WI
Originally Dated July 24, 2026, Last Updated August 25, 2026
Page 61 of 271
About Us
Our Mission: We are committed to Universal Hearing, or the concept that all people, regardless of their level
of impairment, have the right to barrier-free, clear sound and enjoyment of speech, music, and the sound
creation of others, no matter the acoustic environment. We achieve this mission with the use of technology
and design approaches that ensure the highest quality sound with the lowest burden of use. Our success
will be achieved when no one, whether they have “normal” hearing or not, feels disconnected from human
communication or interaction due to poor sound quality or an unreasonable burden of access.
Thunder Hearing & Sound has designed and installed over 500 hearing loop systems ranging from small
meeting rooms and ticket counters to 6,000 seat theaters and university buildings with 25+ classrooms
receiving hearing loops throughout the entire building. As of 2025, we began also offering Auracast (the
newest assistive listening technology) and as of early July 2026, we now offer Caption Companion to assist
facilities with captioning needs.
Our clients include:
• Northwestern University - Evanston, IL
• Purdue University - West Lafayette, IN
• Goodman Theater - Chicago, IL
• Steppenwolf Theater - Chicago, IL
• Milwaukee Repertory Theater - Milwaukee, WI
• Brookfield Library - Brookfield, WI
• Sunset Playhouse Theater - Elm Grove, WI
• Victory of the Lamb Church - Franklin, WI
• Jefferson Public Library - Jefferson, WI
• St. Francis de Sales Church - Lake Geneva, WI
• New Berlin Public Library - New Berlin, WI
• Watertown Public Library - Watertown, WI
• Whitewater Public Library - Whitewater, WI
See all our clients and get your
hearing loop or Auracast on our map
by choosing Thunder Hearing & Sound
Page 62 of 271
Auracast Clients Include:
• Our Lady of the Wayside Catholic Church - Arlington Heights, IL
• Lyric Opera House - Chicago, IL
• Overshadowed Theater - Medinah, IL
• Congregational United Church of Christ - St. Charles, IL
• *Goodman Theater - Chicago, IL
• *St. Patrick Catholic Church - St. Charles, IL (both campuses)
• *Marriott Lincolnshire Theater - Lincolnshire, IL
• *North Congregational Israel - Glencoe, IL
• *St. Gilbert's Catholic Church - Grayslake, IL
• *Metropolis Performing Arts Centre - Arlington Heights, IL
• *Black Ensemble Theater - Chicago, IL
• *Fortnightly of Chicago - Chicago, IL
* Highlights that Client is Offering Both Hearing Loop & Auracast
Page 63 of 271
Meet our team
Steve Thunder
President, Acoustical Engineer & Hearing Loop
Expert
Megan Thunder
Vice President, Chief Operations Manager, Inside
Sales, Project Manager
Dr. Lisa Gumina, AuD.
Dr. of Audiology, Post Installation Training Partner
Page 64 of 271
What You Get
We are committed to installing high quality, state-of-the-art hearing
loop systems that meet international standards. Therefore we will be
with you every step of the way. We thank you for the opportunity to
perform the necessary metal loss testing onsite at the church. This
testing is critical to designing hearing loop systems in accordance
with the International Electrotechnical Commission (IEC) standard
60118-4. We guarantee compliance of seating within the looped
spaces for 93% of seats or better unless otherwise noted for each
space under consideration.
Our proposal is based on using an Ampetronic loop driver.
Equipment comes with a 5-year manufacturer warranty. All the work
we do comes with our 100% satisfaction guarantee and a one-year
warranty against defects in workmanship.
Electromagnetic Interference Testing
While onsite, we tested electromagnetic background noise in the community room. This noise typically
comes from power wiring and is heard as a low frequency hum when listening to the loop system. We found
that throughout the room that this noise meets the IEC standards.
Example Design
System Design and Installation
Based on the test data we have designed a system
for you using our in-house modeling software. We
plan to install a phased array system to ensure that
the signal volume throughout the room is nice and
even to meet the IEC standards.
Page 65 of 271
Wire Installation
We plan to install the wiring throughout each of the rooms above the
suspended ceiling tiles. We will lay our wiring above the ceiling with
strategic anchor points to ensure they stay in place. A feeder wire will
run down from the ceiling inside of wire mold near the AV rack area.
We will connect the loop driver to your existing TV/AV.
Example Designs
Equipment & Materials Include:
• Loop driver with 5 year warranty
• Audio Cables & Mounting Equipment
• Feeder cable
• Loop wire
• Metal wall signs (2 per space)
• Basic Loop Receivers with Headphones (5
total)
Design & Installation Includes:
• Full design drawings
• Complete Wire Installation
• Training Videos
• Post Installation Handouts and System
Promotion Materials
Page 66 of 271
Auracast - The New Audio
Enhancement System
The newest assistive listening technology offers more user options than ever before. Auracast is a wide
area Bluetooth technology that allows an unlimited number of users to connect to your audio system. This
system is recommended in addition to the hearing loop system, but can also be installed as a stand-alone
system. As a new system adopter we are offering special pricing you won't find anywhere else and is for a
limited time.
As of today, Auracast has a smaller number of hearing aids
currently able to connect directly, but the number of hearing aids is
expected to grow over the next few years. (Expecting the top 6
hearing aid manufacturers to all have options by the end of 2026).
The consumer listening options are growing with Auracast enabled
earbuds, headphones and some smartphones (newer Androids
currently), allowing anyone to enhance their listening experience
and participation using their own device. We anticipate this growing
over the next few years and will be the standard system found
across the world.
Page 67 of 271
When the transmitter is mounted, it looks similar to a Wi-Fi access point (offered in both white or black).
Each transmitter offers 2 broadcast channels, allowing flexibility to share room audio and other options such
as translations or audio description. For systems utilizing the receivers, a receiver offers 20+ hours of use
between charges. The charing tray also doubles as an easy firmware update connection for quick receiver
upgrades and setting changes. Neckloops are offered for Auracast only systems to allow hearing aid users
with a t-coil to connect to the system using a neckloop + receiver. Headphones are also offered for those
that don't yet wear hearing aids and may not yet have their own consumer device that is Auracast enabled.
Permanent Wall Mount vs. Portable Kit
Thunder Hearing & Sound understands that facilities need
flexible options to offer their patrons and improve accessibility.
Whether you choose to install the Auracast transmitter
permanently on the wall or use our portable kit, we've got you
covered.
Portable Auracast Kit Includes:
• Hard Rolling Case with Custom Foam Inserts
• 1 Listen Technologies Auri Transmitter with USB-C Power Supply (available in black or white)
• Tripod with Custom Mount (extends between 7-8 feet)
• 4 Auracast Receivers with Headphones
• 4 Neckloops
• XLR Connector Cable (allows you to tie into an existing AV system)
• Auri Manager System Login for Easy System Set Ups
• Tripod Clip with Metal Sign (available in gold or silver)
• Optional Add On - Shure Wired Microphone (Contact for Price Adjustment to Add)
Permanent Auracast Installation Includes:
• Installation Labor
• 1 x Listen Technologies Auri Transmitters with USB-C power
supply (available in black or white)
• Audio Cable
• Auracast Receivers with Headphones (number depends on
application)
• 4 Neckloops (only needed if doing Auracast only installation)
• Auri Manager System Login for Easy System Updates
• 2 Metal Wall Signs (already included if doing dual system
integration)
For the investment page we
have broken down technology
into several options.
• Option 1 - Hearing Loop +
Auracast (our
recommended solution)
• Option 2 - Auracast Only
• Option 3 - Hearing Loop
Only
Page 68 of 271
Caption Companion - Improving your
Accessibility Options, Not Just Audio
Thunder Hearing & Sound is now proud to expand our offerings to include Caption Companion Tablets.
Allowing facilities to expand their accessibility offerings to not only include audio enhancement, but
captioning as well.
Caption Companoin is an 8-inch tablet-style device that offers, free, unlimited, fast and accurate
real-time AI captioning.
• No internet needed
• No subscription, monthly fees, or per-minute charges
• No hassle - just turn it on and it immediately starts transcribing
• Comes uniquely paired with a Bluetooth SmartMic for unprecendented accuracy and versatility
• Easily connects to an Auracast receiver for crystal clear audio feed from anywhere in the room
Purchase of a Caption Companion Tablet Includes:
• 8-Inch Tablet
• USB-C Power Cable
• Bluetooth SmartMic
• Screen Protector Plus Case with Handle/Lanyard Strap
• Adapter Cable to plug into Tablet + Headphone Jack
Additionally, if you want to provide captioning for a large group or event, adding the optional HDMI adapter
allows you to connect the tablet to a computer or projector to include the transcriptions as part of your
presentation.
Page 69 of 271
The Investment *Pricing Guaranteed for 60 Days, Good Thru 9/24/2026
Option 1: Dwight Foster Public Library Hearing Loop + Auracast Price QTY Subtotal
Community Room Hearing Loop System Installation Above Ceiling
Tiles + Auracast (1 Day)
Hearing Loop Wire Installation Attached Above Ceiling Tiles Includes: Ampetronic C
Series Phased Array Loop Driver, Installation Labor, Wire, Feeder Wire, 1 Basic Loop
Receiver with Headphones, 1 Listen Technologies Auracast Transmitter, 6 Auracast
Receivers with Headphones, 1-16 Unit Charging Tray for Auri Receivers, USB-C Power
Supply + Audio Cable, Cart Clamp for Auracast Mounting, Isolation Transformer, 2
Metal Wall Signs, Promotional Materials, Training Videos
$12,650.00 1$12,650.00
Auracast Early Adopter Special Discount
Equipment Discount for Auracast Gear - Limited Time
-$589.40 1 -$589.40
Option 2: Auracast Only
Community Room Auracast System Installation (1/2 Day)
1 Listen Technologies Auracast Transmitter, 6 Auracast Receivers with Headphones, 1-
16 Unit Charging Tray for Auri Receivers, 4 Neckloops, 1xPoE Switcher for Transmitter
Power + Audio Cable/CAT5e Cable, 2 Metal Wall Signs, Promotional Materials, Training
Videos
$7,431.00
1 $7,431.00
Auracast Early Adopter Special Discount
Equipment Discount for Auracast Gear - Limited Time
-$636.24 1 -$636.24
Option 3: Hearing Loop Only
Community Room Hearing Loop Installation (1/2 Day)
Hearing Loop Wire Installation Attached Above Ceiling Tiles Includes: Ampetronic C
Series Phased Array Loop Driver, Installation Labor, Wire, Feeder Wire, 3 Basic Loop
Receiver with Headphones, 2 Metal Wall Signs, Promotional Materials, Training Videos
$7,025.00 1 $7,025.00
Additional Option Items to Consider
Hearing Loop Receiver - Rechargeable Upgrade (Loop Only
Solution)
Fee to Upgrade Provided 5 Hearing Loop Receivers to Rechargeable Receivers,
Includes 1-5 Unit Charging Tray with Power Supply
$781.00 1 $781.00
Portable Auracast Kit
Portable Auracast Kit Includes: Rolling Hard Case with Custom Foam Insert, Listen
Technologies Auracast Transmitter with XLR Connection Cables + USB-C Power
Supply, Tripod with Custom Mount, 4 Auracast Receivers with Headphones, 1-4 Unit
Charging Tray, 4 Neckloops, Tripod Sign Clip + Metal Sign (wired Shure microphone can
be added for additional charge)
$5,000.00 1 $5,000.00
Caption Companion - Live Caption Tablet
Caption Companion Tablet with Case + Bluetooth Microphone
Caption Companion Tablet Includes Case with Screen Protector, Bluetooth Microphone,
Charging Cable, Adapter Cable to Connect to Auracast Receiver
$1,699.00
1 $1,699.00
Page 70 of 271
CC HDMI Adapter Cable
HDMI Adapter Cable to Connect Tablet to Computer for Screen
Presentations/Captioning
$55.00 1 $55.00
Tax $0.00
Total $12,060.60
Page 71 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Fort Atkinson City Council
FROM: Rebecca Houseman, City Manager
RE: Review and possible action relating to Citizen Appointments to Boards,
Commissions and Committees (Houseman, City Manager)
BACKGROUND
The City has a wide variety of Committees, Commissions, and Boards made up of citizens, staff,
and elected officials. Some of these groups are outlined in the City’s Ordinances. Most often,
the City Manager is responsible for appointing citizen members, subject to approval by the City
Council. Similarly, in most cases, the Council President is responsible for appointing Council
members to these groups.
DISCUSSION
The following citizen members are eligible for appointment or reappointment to the
Committees, Commissions, and Boards below for the terms indicated:
Tourism Committee
• Bob Head for a one-year term ending in 2027
Plan Commission
• Loren Gray for a three-year term ending in 2030
Note the following vacancies for citizens on City Commissions, Committees, and Boards:
• Board of Zoning Appeals (two seats)
• Cable Television Committee (two seats)
Page 72 of 271
Staff continues to work on filling these vacancies and encourages members of the public to
submit an application to serve if interested.
FINANCIAL ANALYSIS
The appointments of citizens to these Committees, Commissions, and Boards is not expected to
impact the City financially.
RECOMMENDATION
Staff recommends that the City Council confirm the appointments listed in this memo through
the Consent Agenda.
ATTACHMENTS
1. CSF_BobHead_Redacted
2. Plan Comm Loren Gray_Redacted
Page 73 of 271
City of Fort Atkinson
City Manager’s Office
101 N. Main Street
Fort Atkinson, WI 53538
CITIZEN SERVICE INFORMATION FORM
Name (Print): ______________________________________________ Date: _______________
Last First Middle
Home Address: ______________________ _______
Business Name/Address: ________________________________________________________________
Telephone (Home): _ __________________ (Work): _______________
Email Address: ______________________________________ _______
How long have you lived in the City of Fort Atkinson? ____________________________________ ____
Which Boards, Commissions and/or Committees interest you? __________________________________
__________________________________________________________________________________ ___
Please give a brief overview of your background, experience, interest or concerns in the above areas:
References:
1. ___________________________________________________ Phone: ______
2. ___________________________________________________ Phone:_ _____
_______________________________________
Signature
Return this form to:
City Manager’s Office
101 North Main Street
Fort Atkinson WI 53538
sweihert@fortatkinsonwi.gov
HEAD ROBERT CHRISTOPHER
THE FIRESIDE, 1311 JANESVILLE A
VENUE, FORT ATKINSON, WI 53538
(
09/1975–06/1994; 08/2026–PRESENT
TOURISM COMMISION
• BORN, RAISED IN FOR
T ATKINSON.
• GRADUATE OF FORT ATKINSON, CLASS OF 1994.
• MOVED BACK TO FORT ATKINSON AUGUST, 2026.
• LIFELONG FAN OF FORT ATKINSON.
• MARKETING AND GRAPHIC DESIGN BACKGROUND.
• NEW MARKETING MANAGER AT THE FIRESIDE.
JULIE NORDEEN
ERIN PATTERSON
(
09/18/2026
Page 74 of 271
Page 75 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Fort Atkinson City Council
FROM: Michelle Ebbert, Clerk/Treasurer/Finance Director
RE: Review and possible action relating to a Temporary Retailer's License for BASE
Common Table Harvest Dinner on October 10, 2026, from 4:00 pm - 10:00 pm
(Ebbert, Clerk/Treasurer/Finance Director)
BACKGROUND
The State of Wisconsin regulates alcohol licensing for local governments through Chapter 125.
There are three classes of Licenses: Class A, Class B and Class C. “Class C” pertains strictly to
wine with consumption on-site in a restaurant. The difference between Class A and B is where
alcohol is authorized for sale and for consumption. Class A generally offers sale of alcohol on-
site with consumption off-site (e.g. grocery or liquor store, gas station or convenience
store). Class B allows for on-site sale and on-site consumption (e.g. Restaurant, Bar, Bowling
Alley, Tavern). Class A can easily be remember as you consume alcohol Away from the
premises. Likewise, Class B you consume on-site, for example Bar.
Alcohol licenses are further defined by the quotation marks used. For example, “Class A” refers
to intoxicating liquor while Class “A” refers to fermented malt beverages. These licenses can
also be issued together as a combination license, most common for grocery stores.
Temporary Class “B” (picnic) beer and/or wine licenses may sell fermented malt beverages to
consumers at a picnic or similar gathering of limited duration. Such licenses may be issued only
to bona fide clubs, chambers of commerce, county or local fair associations, agricultural
societies, churches, lodges, societies, veteran’s organizations that have been in existence for at
least six months.
There is no limit to the number of Temporary Class “B” fermented malt beverage licenses that
may be issued to an eligible organization in a calendar year. However, there is a limit of two
Temporary “Class B” wine licenses that may be issued to an eligible organization in a 12-month
period.
Temporary license holders must have licensed operators (bartenders) and they must purchase
their products from a Distributor/Wholesaler.
Page 76 of 271
DISCUSSION
Organization: BASE - Before and After School Enrichment
Street Location: 1233 Janesville Avenue
Manager of affair: Alicia Norris
Name of Event: Common Table Harvest Dinner
Date of Event: October 10, 2026
Premises: The event will be hosted at the BASE Community Building in the multipurpose room.
The beverages area will be set up in the main foyer area outside the multipurpose room.
The Named Organization Applied for the Following License(s): Class “B” Fermented Malt
Beverage License and a "Class B" Wine
FINANCIAL ANALYSIS
There is a $10.00 license fee per Application for Temporary Retailer’s License. Publication is not
required for these licenses.
RECOMMENDATION
Staff recommends that the City Council approve the Temporary Class B Retailer’s License to sell
beer and wine at the Common Table Harvest Dinner at BASE on October 10, 2026 contingent
upon having licensed operators and purchasing products from a Wisconsin beverage
distributor.
ATTACHMENTS
1. Application Redacted
Page 77 of 271
Page 78 of 271
- 2 -AB-220 (R. 1-25)
Part E: For Clerk Use Only
Date Application Was Filed With Clerk License Number
Signature of Clerk/Deputy Clerk
Date License IssuedDate License Granted
15. Premises Description - Describe the building or buildings and any outside areas where alcohol beverages and records are sold,
stored, or consumed, and related records are kept. Describe all rooms within the building, including living quarters. Authorized
alcohol beverage activities and storage of records may occur only on the premises described in this application. Attach a map
or diagram and additional sheets if necessary.
11. Organizer of Event (if not the named applicant)
13. Organizer Website 14. Event Website
Part D: Attestation
READ CAREFULLY BEFORE SIGNING: Under penalty of law, I have answered each of the above questions completely and
truthfully. I agree that I am acting solely on behalf of the applicant organization and not on behalf of any other individual or entity
seeking the license. Further, I agree that the rights and responsibilities conferred by the license(s), if granted, will not be assigned
to another individual or entity. I agree to operate according to the law, including but not limited to, purchasing alcohol beverages
from Wisconsin-permitted wholesalers. I understand that lack of access to any portion of a licensed premises during inspection will
be deemed a refusal to allow inspection. Such refusal is a misdemeanor and grounds for revocation of this license. I understand
that any license issued contrary to Wis. Stat. Chapter 125 shall be void under penalty of state law. I further understand that I may
be prosecuted for submitting false statements and affidavits in connection with this application, and that any person who knowingly
provides materially false information on this application may be required to forfeit not more than $1,000 if convicted.
Who must sign this application?
• one officer or director of the nonprofit organization
Signature
Title
Last Name First Name M.I.
Part C: Event Information
1. Name of Event (if applicable)
2. Dates of Operation
4. Premises Address
5. City 6. State 7. Zip Code
3. Hours of Operation
10. Aldermanic District9. Governing Municipality
of:
8. County City Town Village
Common Table Harvest Dinner
10/10/2026
10/10/2026
4-10pm
1233 Janesville Ave
Fort Atkinson
WI
53538
Jefferson
✔
Fort Atkinson
www.basefortatkinson.org
www.basefortatkinson.org/harvestdinner
The event will be hosted at the BASE Community Building in the multipurpose room. We
will have the beverage area set up in the main foyer area outside of the multi-purpose
room. Beverages will be stored in a kitchenette with lockable cabinets and doors
during the event and in the walk in cooler in our locked commercial kitchen 1 day
before the event.
Norris
Executive Director
09/18/26
Page 79 of 271
Page 80 of 271
- 2 -AB-100 (R. 1-25)
Part E: Attestation
READ CAREFULLY BEFORE SIGNING: Under penalty of law, I have answered each of the above questions completely and
truthfully. I certify that I am not prohibited from participating in this business due to any involvement in another tier of the alcohol
beverage industry as a restricted investor. I understand that any license issued contrary to Wis. Stat. Chapter 125 shall be void
under penalty of state law. I further understand that I may be prosecuted for submitting false statements and affidavits in connection
with this application, and that any person who knowingly provides materially false information on this application may be required
to forfeit not more than $1,000 if convicted.
Signature Date
Part D: Criminal History
Law/Ordinance Violated
1. Have you ever been convicted of any offenses (excluding traffic offenses unless related to alcohol beverages)
for violation of any federal, Wisconsin, or another state’s laws or of any county or municipal ordinances? ...... Yes No
If yes to question 1, please list details of each conviction below. Attach additional sheets as needed.
Penalty Imposed
Conviction Date
2. Are charges for any offenses currently pending against you (excluding traffic offenses unless related to alcohol
beverages) for violation of any federal, Wisconsin, or another state’s laws or any county or municipal
ordinances?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No
If yes to question 2, describe nature and status of pending charges using the space below. Attach additional
sheets as needed.
Was sentence completed? ..... Yes No
Location
Law/Ordinance Violated Conviction Date
Penalty Imposed
Was sentence completed? ..... Yes No
Location
Law/Ordinance Violated Conviction Date
Penalty Imposed
Was sentence completed? ..... Yes No
Location
✔
✔
09/21/2026
Page 81 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Fort Atkinson City Council
FROM: Zach Navin, Director of Public Works
RE: Review and possible action relating to a Resolution Adopting the 2027
Stormwater Utility Rate (Navin, Director of Public Works)
BACKGROUND
In 2024, the City contracted with Trilogy Consulting, LLC to evaluate the financial condition of the City’s
utilities and develop long-term projections for revenues, expenses, capital needs, debt obligations, and
reserve levels. Trilogy presented its updated Stormwater Utility financial analysis to the City Council on
November 19, 2024. The analysis identified the need for a series of rate increases to ensure the
Stormwater Utility could continue funding routine operations, infrastructure maintenance and
replacement, debt service associated with the Public Works and Parks Facility, future Total Maximum
Daily Load (TMDL) projects, and the rebuilding of adequate financial reserves.
As part of that plan, the Stormwater Utility rate increased by 15% in 2026, establishing the current annual
rate of $90.60 per Equivalent Runoff Unit (ERU). Trilogy’s original projection contemplated a 10% increase
for 2027, followed by a 5% increase in 2028 and inflationary increases of approximately 3% annually
thereafter. Since completion of that analysis, the Utility has experienced higher-than-anticipated costs
associated with several significant stormwater projects, including emergency work on Milwaukee Avenue
West and the South Fourth Street storm sewer cleaning, televising, and locating project. These costs
demonstrate how quickly unplanned or larger-than-anticipated infrastructure needs can affect the
Utility’s available reserves.
For that reason, staff is proposing a 15% rate increase for 2027, rather than the 10% increase originally
projected by Trilogy.
DISCUSSION
Page 82 of 271
The Stormwater Utility is currently able to meet its operating and capital obligations; however,
maintaining that position requires continued attention to both annual revenues and long-term
infrastructure needs. Stormwater expenditures can vary significantly from year to year.
Emergency repairs, unforeseen project conditions, and the need to investigate or replace aging
infrastructure can create substantial expenses that were not anticipated when the original
financial projections were prepared. Recent examples include the South Main Street project
change order and the South Fourth Street storm sewer investigation.
In addition to these near-term needs, the Utility must continue planning for future system
replacement and TMDL-related improvements. Trilogy estimated that future TMDL projects
alone could total approximately $3 million to $5 million, making the restoration and
maintenance of adequate reserves an important component of the Utility’s long-term financial
strategy. A 15% increase would raise the annual Stormwater Utility rate from $90.60 to
$104.19 per ERU, an increase of $13.59 per year for a single-family residential property.
Staff believes the proposed rate provides a reasonable approach to maintaining the financial
stability of the Utility while continuing to fund necessary maintenance, infrastructure
replacement, debt obligations, and future capital improvements.
FINANCIAL ANALYSIS
If approved, the Stormwater Utility rate would increase from $90.60 to $104.19 per ERU per
year, effective January 1, 2027. For a single-family residential property assessed one ERU, this
represents an increase of $13.59 annually, or approximately $1.13 per month. The proposed
rate has been incorporated into the 2027 Budget presented to the City Council during the
September 29, 2026 Budget Workshop.
RECOMMENDATION
Staff recommends that the City Council adopt the Resolution establishing the 2027 Stormwater
Utility rate at $104.19 per ERU per year, effective January 1, 2027
ATTACHMENTS
1. Trilogy 2024 Stormwater Financials
2. 2027 draft Stormwater Rates resolution
Page 83 of 271
1
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (920)723-2169•FAX: (262)436-2102•www.trilogy-llc.com
STORMWATER UTILITY FINANCIAL PLANNING
October 2024
Financial Projections and User Rates
The City hired Trilogy Consulting to prepare the annual review of the Stormwater Utility’s
progress in meeting its financial goals and assess any needed updates to Utility policies and rates.
The Stormwater Utility was first implemented in September of 2009. Each property in the City is
assigned a number of Equivalent Residential Units (ERUs), based on the amount of impervious
area that contributes to storm water runoff. One ERU equals 3,096 square feet of impervious
surface area. Every single -family home is assigned one ERU, with non -residential properties
assigned ERUs based on actual measured impervious area. The original rate was $27.60 per ERU
per year. Rates gradually increased to the rate of $52.50 in 2020 and were set at $65.63 for 2024,
a 25 percent increase. The increase in rates are projected to result in an increase in revenues of
about $140,000 from 2023 to 2024. Further, the large negative cash flow experienced in 2023 is
projected to be diminished to about a break even, depending on any remaining unplanned work
during the rest of 2024.
Page 84 of 271
2
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (920)723-2169•FAX: (262)436-2102•www.trilogy-llc.com
As of year-end 2022, the Utility had reserves of $490,000 . At year-end 2023, reserves had been
drawn down to about $165,000 to pay for capital projects, and they are projected to remain at a
similar level by the end of 2024. As discussed in 2023, it is recommended that the Utility maintain
a minimum operating reserve comprised of 2 month’s operating expenses ($62,000 in 2025), a
full year’s debt service payments ($197,000 in 2025), and $100,000 for emergency capital needs.
For 2025, the minimum recommended reserve level would be about $359,000.
To continue the plan to build back Utility reserves while ensuring that annual obligations are
satisfied, a 20 percent increase in the ERU rate ($65.63 to $78.60) is recommended for 2025, the
same increase that was projected in the prior analysis . Additional increases in future years are
recommended to keep the Utility financially healthy . Needed increases in future years are
projected to be 15 percent in 2026 ($78.60 to $90.60), 10 percent in 2027 (to $99.60), 5 percent
in 2028 (to $104.40), and inflationary increases of 3 percent annually thereafter. Inflation in O&M
expenses is assumed to be about 3.0 percent annually beginning in 2025. The charts below show
the Utility’s projected cash needs compared to revenues at both present and proposed rates.
2
2 2 2 2 2 2 2 2 2 2 22 2 2
evenue xpense istory
xpenses ebt ervice apital mprovements et of ebt ssued nnual evenues
Page 85 of 271
3
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (920)723-2169•FAX: (262)436-2102•www.trilogy-llc.com
2
2
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
xpense rojec ons and evenues at urrent ates
xpenses ebt ervice apital mprovements et of ebt ssued evenues at urrent ates
Page 86 of 271
4
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (920)723-2169•FAX: (262)436-2102•www.trilogy-llc.com
Reserve Management for Capital Projects
Building on the analysis prepared in 2023 , Trilogy updated cash flow projections that would
estimate the amount of annual cash that can be built up in reserves and then available for TMDL
projects that are mandated by the DNR but do not have a set schedule for implementation. These
projects will total somewhere between $3 Million and $5 Million, but again do not currently have
a deadline for implementation. Before it can do that, however, the Utility should build up its
operating reserve to a minimum level to ensure its long and short -term financial health. The
following graph shows a n updated look at cash flow and reserve levels under the proposed
schedule of rate increases, both unrestricted reserves to be maintained for operating purposes,
and a new assigned reserve for future TMDL projects. This projects that the utility will have built
up funds to be used for TMDL projects beginning in 2029.
2
2
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
xpense istory and rojec ons of evenues at roposed ates
xpenses ebt ervice apital mprovements et of ebt ssued evenues at roposed ates
Page 87 of 271
5
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (920)723-2169•FAX: (262)436-2102•www.trilogy-llc.com
2
2
2
2 2 2 2 2 2 2 2 2 2 2 2 2
rojected ash lo and eserve evels
otal evenues et ash lo otal ash xpenses Unrestricted eserves ssigned eserves rojects
Page 88 of 271
6
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (920)723-2169•FAX: (262)436-2102•www.trilogy-llc.com
The final chart below shows the annual charge per ERU for those other communities within the
greater Rock River Basin that have stormwater utilities and that charge on an ERU (or similar)
basis, along with the proposed increases through 2026 . The median annual charge (excluding
Fort Atkinson) is about $84 per year ($3 higher than 2023) . Several of these communities have
increased their stormwater charges in the last several years , including 2024, and may also be
facing increases in the future to fund mandated capital spending.
Page 89 of 271
7
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (920)723-2169•FAX: (262)436-2102•www.trilogy-llc.com
.
2 .
.
.
.
.
2 .
.
.
.
nnual ill omparison of egional ommuni es 2 2
Page 90 of 271
RESOLUTION NO. _____
RESOLUTION
ADOPTING 2027 STORMWATER UTILITY RATE
WHEREAS, Chapter 98 of the City of Fort Atkinson Municipal Code provides
regulations relating to Municipal Utilities; and
WHEREAS, Article V of Chapter 98 regulates the City’s Stormwater Utility
(hereinafter “Utility”); and Section 98-604 outlines rates and charges; and
WHEREAS, Section 98-604(a) indicates that user charges shall be imposed on all
developed property with impervious area in the City to recover all or a portion of the costs
of the Utility; that the amount of such charges shall be based on a rate per equivalent
runoff unit (ERU); and that the City Council shall establish the rate per ERU through a
resolution; and
WHEREAS, all developed property with impervious area shall be assigned ERUs.
Each single-family residential property shall be assigned one ERU; each two-family
residential property shall be assigned 0.7 ERUs/dwelling unit; each three- and four-family
residential property shall be assigned 0.5 ERUs/dwelling unit; and nonresidential property
shall be assigned ERUs based upon the amount of impervious area on the property divided
by 3,096 square feet, however shall not be less than one ERU; and
WHEREAS, the user rate per ERU was updated in 2024 after the City Council
commissioned a Utility rate study from Trilogy Consulting, LLC, which was presented to
the City Council in November 2023, and updated at the November 19, 2024 City Council
meeting; and
WHEREAS, Trilogy Consulting, LLC, through the 25-year projection of user rates,
cash flows, debt obligations, and future capital projects, recommends that the Utility
implement annual rate increases, including a 15% rate increase in 2027, to complete all
necessary capital improvement projects and meet all debt requirements while maintaining
the financial health of the Utility.
NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Fort Atkinson,
Jefferson County, Wisconsin, that the 2027 Utility rate is $104.19 per ERU.
Page 91 of 271
BE IT FURTHER RESOLVED that the rate of $104.19 per ERU be implemented as of
January 1, 2027.
Adopted and effective this 6th day of October 2026.
CITY OF FORT ATKINSON
_______________________________
Kyle Jaeckel, Council President
ATTEST:
__________________________________________________
Michelle Ebbert, City Clerk/Treasurer/Finance Director
Page 92 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Fort Atkinson City Council
FROM: Zach Navin, Director of Public Works
RE: Review and possible action relating to a Resolution Adopting the 2027
Wastewater Utility Rates (Navin, Director of Public Works)
BACKGROUND
In 2024, the City Council authorized staff to work with Trilogy Inc. to aid in evaluating the
current financial picture of the City's three utilities as well as look at forecasting future
expenses and revenues. During the 2026 budget process, the Council has reviewed the need for
an increase in utility rates to meet anticipated expenses, as documented in more detail in the
attached analyses. Trilogy provided a presentation at the November 19, 2024 council meeting
on their work. Staff has noted the salient points below and included the memo for each utility
as an attachment.
• The last full rate study was completed in 2020
• Overall increases of 6% per year were implemented in 2021, 2022, and 2023
• 2020 rate study projected 3% per year increases for 2024 and future years
• Recommended to continue with moderate annual rate increases based on updated
revenues and expenses
• Rates were increased 3% in 2026
• Recommend another 3% increase for 2027
• Utility is projected to draw down reserves over the next few years through capital
spending, but maintain a healthy fund balance
DISCUSSION
Overall the City's Wastewater Utility is in good financial shape. Continued rate increases are a
sustainable way to keep the Utility in a healthy financial position while completing necessary
capital plant upgrades and collection system maintenance and infrastructure replacement.
FINANCIAL ANALYSIS
If the Resolution is adopted by the City Council, the proposed rate increases would be effective
on January 1, 2027. This rate increase has been incorporated into the 2027 Budget document
presented to the City Council at the September 29th Budget Workshop.
Page 93 of 271
RECOMMENDATION
Staff recommends that the City Council adopt the Resolution establishing the 2027 Wastewater
Utility Rates as presented in the attached resolution.
ATTACHMENTS
1. Trilogy 2024 Wastewater Financials
2. Resolution Adopting 2027 Wastewater Utility Rates
Page 94 of 271
1
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (262)470-2277•FAX: (262)436-2102•www.trilogy-llc.com
SEWER UTILITY FINANCIAL PLANNING
October 2024
Financial Projections and User Rates
In 2020, the City retained Trilogy Consulting to prepare a Sewer Rate Study to develop
recommended sewer rates to fund major upgrades to the wastewater treatment facility. The
study, dated October 2020, recommended a series of three annual rate increases of 6.0 percent
per year for 2021 through 2023 to provide sufficient revenues for debt coverage for the Clean
Water Fund (CWF) loan for the wastewater treatment facility project. The City adopted the rates
in November 2020.
A 25-year projection of user rates and cash flows was also prepared as part of the Sewer Rate
Study to develop a plan to complete all necessary capital improvement projects and meet all debt
requirements while maintaining the financial health of the Utility. A series of 3.0 percent per year
rate increases were projected to be needed for 2024 and following years to allow the Utility to
cash fund routine capital improvements while maintaining cash reserves at or above the
recommended minimum level. The study also recommended that these future rate increases
should be evaluated annually so that adjustments can be made to changes to the assumptions
built into the cash flow projections.
In 2023, Trilogy Consulting completed an update to the cash flow projections for the Sewer
Utility, recommending a 3.0 rate increase for 2024, and projecting the need for rate increases of
4.0 percent per year for 2025 through 2028.
This analysis was updated again in 202 4 to review the recommended rates for 2025 and future
years. Based on the updated analysis, rate increases of 3.0 percent per year are projected for
2025 through 2029. The update included:
• Updating the projections with actual sewer utility sales, operation and maintenance
expenses, revenues, capital expenditures, cash flows, and reserve balances for 2023
through third quarter 2024.
• Updating the future capital imp rovement expenditures to incorporate the Utility’s
estimated 2024 capital improvements and the 2025-2030 Capital Improvement Program.
• Adjusting future projections of sales, revenues, and expenses based on recent trends and
the Utility’s 2025 budget.
Page 95 of 271
2
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (262)470-2277•FAX: (262)436-2102•www.trilogy-llc.com
The Utility’s rate structure was also modified to: 1) include the industrial sampling costs into the
rates per pound charged to high- strength industrial customers for pollutants loadings above
normal domestic strength; and 2) develop rates per hundred cubic feet of wastewater for high-
strength commercial customers that include the estimated pollutant loadings for each class of
high strength commercial customer (fast food restaurant, sit down restaurant, and food store).
Based on this analysis, current and proposed 2025 sewer rates are shown on the following page.
Page 96 of 271
3
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (262)470-2277•FAX: (262)436-2102•www.trilogy-llc.com
Flat Charge
Connection
Size 2024
Proposed
Rates - 2025
Percent
Change
5/8 $24.93 $25.68 3 %
3/4 $24.93 $25.68 3%
1 $40.17 $41.38 3%
1 1/4 $52.53 $54.11 3%
1 1/2 $63.90 $65.82 3%
2 $93.70 $96.51 3%
3 $137.40 $141.52 3%
4 $168.10 $173.14 3%
6 $270.27 $278.38 3%
Usage Charges
Units 2024
Proposed
Rates - 2025
Percent
Change
Domestic Sewage $/CCF $2.67 $ 2.76 3%
High-Strength Commercial
Fast Food Restaurant $/CCF $13.39 $13.79 3%
Food Store $/CCF $5.33 $5.49 3%
Sit Down Restaurant $/CCF $7.56 $7.79 3%
High-Strength Industrial
Flow $/CCF $2.67 $2.76 3%
$/1,000 gals $3.56 $3.69 4%
BOD $/pound $0.48 $0.54 13%
TSS $/pound $0.68 $0.75 10%
Phosphorus $/pound $3.86 $4.03 4%
TKN $/pound $1.39 $1.48 7%
Septic Tank $/CCF $32.09 $33.05 3%
$/1,000 gals $42.90 $44.18 3%
Holding Tank - Residential $/CCF $9.19 $9.46 3%
$/1,000 gals $12.28 $12.65 3%
Holding Tank - Commercial $/CCF $11.05 $11.38 3%
$/1,000 gals $14.77 $15.21 3%
Landfill Leachate $/CCF $19.26 $19.84 3%
$/1,000 gals $25.75 $26.52 3%
Page 97 of 271
4
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (262)470-2277•FAX: (262)436-2102•www.trilogy-llc.com
Cash Available for Capital
To help with future capital planning, the Utility asked Trilogy to prepare cash flow projections
that estimate the amount of annual cash that is available for capital projects . Considering
increases in operation and maintenance expense s, principal and interest payments for existing
debt, conservative projections of future sales, and rate increases of 3.0 percent per year, the
Utility is projected to be able to fund about $4.1 million of capital projects from funds borrowed
in 2024 for the WWTP solar project and annual revenues between 2025 and 2030. With over $6.6
million in planned capital improvement projects for 2025 through 2030 , the Utility is projected
to draw down its cash reserves by almost $2.5 million over the next several years. In addition,
the City is plann ing to loan $1.0 million of Utility funds to TID No. 9, expected to be paid back
beginning in 2035.
As shown in the table below, the Utility’s cash reserves are currently well above the
recommended target reserve levels. At year end 2023 the Utility had $3.9 million of unrestricted
cash and just under $1.4 million in the Equipment Replacement Fund (ERF). At a minimum, the
Utility is required by the Wisconsin Department of Natural Resources to maintain an ERF balance
equal to 10 percent of the value of its e quipment, or currently about $1.0 million. No additional
deposits to the ERF are necessary currently. However, if the Utility uses these funds for
unplanned equipment replacement, funds may need to be added to replenish these funds in the
future. Even after using $2.5 million of reserves to fund capital projects over the next six years
and loaning funds to TID No. 9, the Utility’s reserve funds are projected to remain at about the
recommended target reserve levels.
These projections are based on numerous assumptions regarding trends in customer sales,
inflation, and the Utility’s Capital Improvement Program. The Utility should continue to evaluate
the rates regularly and adjust the rates as needed to adapt to changing conditions , continue to
support adequate spending on repairs and replacements, and maintain prudent reserves.
Page 98 of 271
5
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (262)470-2277•FAX: (262)436-2102•www.trilogy-llc.com
2023 2024 2025 2026 2027 2028 2 029 2030
Actual / Projected Rate Increase 6.0% 3.0% 3.0% 3.0% 3.0% 3.0% 3.0% 0.0%
Total Cash In $3,947,128 $3,757,332 $3,797,786 $3,893,085 $3,999,854 $4,104,845 $4,221,640 $4,219,860
O&M Expenses $2,231,048 $2,198,881 $2,260,325 $2,276,282 $2,293,068 $2,309,665 $2,430,706 $2,447,651
PILOT to Water Utility for Meters $47,706 $50,091 $52,596 $55,226 $57,987 $60,886 $63,931 $67,127
Debt Service $836,445 $907,902 $1,156,454 $1,151,318 $1,150,086 $1,074,780 $1,075,396 $1,070,911
Cash Flow Available for Capital $831,930 $600,457 $328,411 $410,259 $498,714 $659,513 $651,608 $634,171
Borrowing / CWF Principal Forgiveness $3,006,688 $1,714,859 $1,500,000 $0 $0 $0 $0 $0
Total Available for Capital $3,838,618 $2,315,316 $1,828,411 $410,259 $498,714 $659,513 $651,608 $634,171
Actual / Planned Capital Outlay $3,677,941 $2,357,235 $2,484,000 $800,000 $1,155,000 $835,000 $750,000 $610,000
Loan to TID #9 $1,000,000
Projected Addition to / (Decrease of) Cash $160,677 ($41,919) ($1,655,589) ($389,741) ($656,286) ($175,487) ($98,392) $24,171
Projected Reserve Balance at Year End
Operating / Capital $3,956,083 $3,914,164 $2,258,575 $1,868,834 $1,212,548 $1,037,061 $938,669 $962,840
Equipment Replacement Fund $1,394,079 $1,394,079 $1,394,079 $1,394,079 $1,394,079 $1,394,079 $1,394,079 $1,394,079
Total $5,350,162 $5,308,243 $3,652,654 $3,262,913 $2,606,627 $2,431,140 $2,332,748 $2,356,919
Recommended Reserves
3 Months's Operating Expenses $557,762 $549,720 $565,081 $569,071 $573,267 $577,416 $607,676 $611,913
Unrestricted Capital $400,000 $400,000 $400,000 $400,000 $400,000 $400,000 $400,000 $400,000
Equipment Replacement Fund $1,394,079 $1,394,079 $1,394,079 $1,394,079 $1,394,079 $1,394,079 $1,394,079 $1,394,079
Total $2,351,841 $2,343,799 $2,359,160 $2,363,150 $2,367,346 $2,371,495 $2,401,755 $2,405,992
Projected Debt Coverage 2.23 1.73 1.36 1.45 1.54 1.63 1.63 1.62
Page 99 of 271
6
169 E Wisconsin Ave, Suite R, Oconomowoc WI 53066•PHONE: (262)470-2277•FAX: (262)436-2102•www.trilogy-llc.com
Page 100 of 271
RESOLUTION NO. _____
RESOLUTION
ADOPTING 2027 WASTEWATER UTILITY RATES
WHEREAS, Chapter 98 of the City of Fort Atkinson Municipal Code provides regulations
relating to Municipal Utilities; and
WHEREAS, Article IV of Chapter 98 regulates the City’s Wastewater Utility (also known
as Sewer Utility, hereinafter “Utility”); and Division 9 outlines charges and fees; and
WHEREAS, Section 98-361 includes a policy that states that the Utility obtain sufficient
revenues to pay the costs of the debt retirement, including any debt service reserves and debt
coverage required, annual cash funded capital outlay, and the operation and maintenance of
the wastewater facilities, including replacement costs, through a system of sewer service
charge. The system shall be based on a cost of service study that assures that each user of the
wastewater facilities pays a proportionate share of the costs; and
WHEREAS, the City Council commissioned a Utility rate study from Trilogy Consulting,
LLC, and that study was presented to the City Council at the meeting on November 17, 2024;
and
WHEREAS, Trilogy Consulting, LLC, through the 25-year projection of user rates, cash
flows, debt obligations, and future capital projects, recommends that the Utility implement
annual rate increases; and
WHEREAS, the rate increase for 2027 will be about 3%, to complete all necessary capital
improvement projects and meet all debt requirements while maintaining the financial health of
the Utility.
NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Fort Atkinson,
Jefferson County, Wisconsin, that the following flat charges and user rates be implemented as
of January 1, 2027:
Connection Size(Meter) 2024 2025 2026 2027
5/8" $24.93 $25.68 $26.45 $27.243/4" $24.93 $25.68 $26.45 $27.241" $40.17 $41.38 $42.62 $43.901 1/4" $52.53 $54.11 $55.73 $57.401 1/2" $65.82 $67.79 $69.83 $71.922" $96.51 $99.41 $102.39 $105.463" $137.40 $141.52 $145.77 $150.144" $168.10 $173.14 $178.33 $183.686" $270.27 $278.38 $286.73 $295.33
TABLE 1: FLAT CHARGES (2024-2027)
Flat Charges
Page 101 of 271
Adopted this 6th day of October 2026.
CITY OF FORT ATKINSON
Kyle Jaeckel, City Council President
ATTEST:
Michelle Ebbert, City Clerk/Treasurer/Finance Director
Units 2024 2025 2026 2027Domestic Sewage$/CCF $2.67 $2.76 $2.84 $2.93$/CCF $32.09 $33.05 $34.04 $35.06$/1,000 galsper load $42.90 $44.18 $45.51 $46.88$/CCF $9.19 $9.46 $9.75 $10.04$/1,000 galsper load $12.28 $12.65 $13.03 $13.42$/CCF $11.05 $11.38 $11.72 $12.07$/1,000 galsper load $14.77 $15.21 $15.67 $16.14$/CCF $19.26 $19.84 $20.43 $21.04$/1,000 galsper load $25.75 $26.52 $27.32 $28.14
CommercialUnits 2024 2025 2026 2027$/CCF $13.39 $13.79 $14.20 $14.63$/CCF $5.33 $5.49 $5.65 $5.82$/CCF $7.56 $7.79 $8.02 $8.26IndustrialUnits 2024 2025 2026 2027$/CCF $2.67 $2.76 $2.84 $2.93$/1,000 gals $3.56 $3.69 $3.80 $3.91BOD$/pound $0.48 $0.54 $0.56 $0.58TSS$/pound $0.68 $0.75 $0.77 $0.79Phosphorus$/pound $3.86 $4.03 $4.15 $4.27TKN$/pound $1.39 $1.48 $1.52 $1.57
TABLE 2: USAGE CHARGES (2024-2027)
Usage Charges
Septic Tank
Holding Tank -Residential
Holding Tank -Commercial
Landfill Leachate
High-Strength Surcharge Rates
Flow
Page 102 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Fort Atkinson City Council
FROM: Jedidiah Draeger, Director of Neighborhood and Building Services
RE: First reading of a proposed Annexation Ordinance relating to the annexation of
the property located at N1807 South Main Street (parcel number 016-0514-
0941-030) to the City of Fort Atkinson from the Town of Koshkonong (PFA-
2026-02) (Draeger, Director of Neighborhood and Building Services)
BACKGROUND
Annexations in Wisconsin are governed by Wisconsin State Statute 66.0217, which
establishes the legal procedures and requirements for incorporating territory from a
town into a city or village. The statute outlines the methods of annexation, petition
requirements, notice and public hearing procedures, and review by the Wisconsin
Department of Administration. It also requires a determination that the annexation is in
the public interest and ensures that statutory standards related to contiguity, boundary
regularity, and service provision are met prior to approval. The Plan Commission will
review the proposed Annexation and a Certified Survey Map (CSM) associated with the
annexation at a meeting on October 13, 2026. The assigned zoning classification will be
Single-Family Residential-5 (SR-5).
DISCUSSION
The subject property is currently located in the Town of Koshkonong, and the applicant is requesting
annexation into the City. In conjunction with the proposed annexation, the applicant is requesting an
SR-5 Single-Family Residential zoning designation.
Upon approval of the annexation, the 1.28-acre parcel is proposed to be divided through a Certified
Survey Map (CSM) into four individual residential lots, each meeting the minimum dimensional and
area requirements of the proposed SR-5 zoning district. The proposed zoning is consistent with the
City's Comprehensive Plan, which identifies the property for Single-Family Residential future land
use. The surrounding properties within the City are similarly zoned for single-family residential use,
with nearby properties also designated for duplex and MRL-8 multifamily residential development.
As a result, the proposed annexation and zoning would provide a logical continuation of the existing
residential development pattern in the area.
City Staff is working with the applicant to coordinate the installation of sanitary sewer and water
laterals to each of the proposed lots prior to completion of the S. Main St. project. Installing these
utilities as part of the current project will help avoid the need to reopen the newly completed roadway
Page 103 of 271
in the future to provide utility connections to the individual lots.
City Staff also contacted WE Energies to determine whether natural gas service could be extended
to the proposed lots in conjunction with the street improvements. WE Energies declined, indicating
that installation of gas services to vacant lots is not part of its current process. Gas service will
instead be installed when construction of individual homes occurs.
The Petition for Annexation was submitted to the Wisconsin Department of Administration in
accordance with applicable state statutes. The proposed annexation was subsequently determined
to be in the public interest.
Jason Schultz, the property owner, is seeking annexation of the property from the Town of
Koshkonong into the City to facilitate the development of a four-lot residential subdivision. The
proposed annexation would allow the property to be developed consistent with the City's
Comprehensive Plan and surrounding residential land uses while providing additional housing
opportunities within the community.
Overall, the proposed annexation and development represent an investment in the community and
provide an opportunity to add new residential housing in an area planned and designated for
residential development. The proposal also allows the City to coordinate the extension of municipal
utilities with the ongoing S. Main St. improvements, supporting efficient infrastructure installation and
reducing the potential for future disruption to the completed roadway.
FINANCIAL ANALYSIS
The proposed annexation is not anticipated to have a direct financial impact on the City. However,
the subsequent division and development of the property into four buildable residential lots will
expand the City's tax base and provide additional taxable property and housing units within the City.
RECOMMENDATION
Staff recommends the City Council perform the first reading of the annexation ordinance
and direct the City Manager to prepare it for the second and possible third/final reading
at the meeting on October 20, 2026, provided that the Plan Commission provides a
positive recommendation at the meeting on October 13, 2026.
ATTACHMENTS
1. 2026 Certified Survey Map App (CSM)_Redacted
2. 14868_20260908_DOA-mbr review letter
3. 260514-SCHULTZ_N1807SMAINannexSent072126
4. CSM
5. Petition for Direct Annexation by Unanimous Approval
6. Petition to Attach or Annex to C. Fort Atkinson12
7. WIAnnexationReviewRequestForm_2026_draft_Redacted
8. Annexation Ordinance -Schultz South Main
Page 104 of 271
City of Fort Atkinson
City Manager’s Office
101 N. Main Street
Fort Atkinson, WI 53538
Certified Survey Map Review Page 1 of 2
City of Fort Atkinson Certified Survey Map Application
This form is designed to be used by the Applicant as a guide to submitting a complete application for
review of a Certified Survey Map by the City to process the application.
APPLICANT Name, company, and client (if applicable):
Phone number Email:
OWNER Name
, company, and client (if applicable):
Phone number: Email:
Postal addres
s for proposed CSM:
_
_
Parcel Identification Numbers Involved:
_
_
Brief description of proposed division or combination and purpose:
_
_
_
I Application Packet Requirements
The Applicant shall submit one electronic copy of the application.
A map of the subject property to scale depicting:
All lands and boundaries for the parcel(s)
Current zoning of the subject property and its environs, and the
jurisdiction(s) which maintains that control.
All lot dimensions of the subject property.
A graphic scale and a north arrow.
Legal Description
All easements, setbacks or land restrictions on the parcel(s)
Ryan Schultz, OpeningDesign
Jason Schultz
N1807 S MAIN ST.
FORT ATKINSON, WI 53538
016-0514-0941-030
Proposing to divide the lot into (4) SR-5 single family lots.
Page 105 of 271
Page 106 of 271
State of Wisconsin Department of Administration
Tony Evers, Governor
Kathy Blumenfeld, Secretary
Dawn Vick, Division Administrator
Division of Intergovernmental Relations
Date: September 08, 2026 PETITION FILE NO. 14868
To: MICHELLE EBBERT, CLERK
CITY OF FORT ATKINSON
101 N MAIN STREET
FORT ATKINSON, WI 53538-1861
CAITLIN KINCANNON, CLERK
TOWN OF KOSHKONONG
W5609 STAR SCHOOL ROAD
FORT ATKINSON, WI 53538
From: Municipal Boundary Review
PO Box 1645, Madison WI 53701
Voice (608) 261-6097 Fax (608) 264-6104
Email: wimunicipalboundaryreview@wi.gov
Web: http://doa.wi.gov/municipalboundaryreview
Subject: SCHULTZ ANNEXATION
The proposed annexation submitted to our office on August 18, 2026, has been reviewed and found to be in the
public interest. In determining whether an annexation is in the public interest, s. 66.0217 (6), Wis. Stats. requires the
Department to examine "[t]he shape of the proposed annexation and the homogeneity of the territory with the
annexing village or city…." so as, to ensure the resulting boundaries are rational and compact. The statute also
requires the Department to consider whether the annexing city or village can provide needed municipal services to
the territory. The subject petition is for territory that is reasonably shaped and contiguous to the CITY OF FORT
ATKINSON, which is able to provide needed municipal services.
Surveyor’s Note: Per s. 66.0217 (1) (c), Wis. Stats. the metes and bounds description of the territory to be annexed
must commence from a monumented corner of the 1/4-section in which the territory lies.
The Department reminds clerks of annexing municipalities of the requirements of s. 66.0217 (9)(a), Wis. Stats.,
which states:
"The clerk of a city or village which has annexed shall file immediately with the secretary of administration a
certified copy of the ordinance, certificate and plat, and shall send one copy to each company that provides any
utility service in the area that is annexed. The clerk shall record the ordinance with the register of deeds and file a
signed copy of the ordinance with the clerk of any affected school district..."
State and federal aids based on population and equalized value may be significantly affected through failure to file
with the Department of Administration. Please file a copy of your annexing ordinance, including a statement
certifying the population of the annexed territory. Please include your MBR number 14868 with your ordinance.
Ordinance filing checklist available at http://mds.wi.gov/, click on "Help on How to Submit Municipal Records".
Email scanned copy of required materials (color scan maps with color) to mds@wi.gov or mail to: Wisconsin
Department of Administration, Municipal Boundary Review, PO Box 1645, Madison WI 53701-1645.
The petition file is available for viewing at: http://mds.wi.gov/View/Petition?ID=2944
Please call me at (608) 261-6097, should you have any questions concerning this annexation review.
Sincerely,
Page 107 of 271
Bradley T. Vowels-Katter
Municipal Boundary Review – DOA
Direct (608) 261-6097
bradley.vowelskatter@wisconsin.gov
http://doa.wi.gov/municipalboundaryreview
cc: petitioner
Page 108 of 271
S T R E E TS O U T H M A I N
IRON PIPE FOUND (1 3/8" Outside Diam. unless Noted)
INDICATES RECORDED AS
DISTANCES ARE MEASURED TO THE
LEGEND
( )
NEAREST HUNDREDTH OF A FOOT.
JEFFERSON COUNTY ZONE NAD83(11)
WISCONSIN COUNTY COORDINATE SYSTEM
BEARINGS ARE REFERENCED TO THE
50' 0' 50'
C. S. M. 1 5 6 6
L O T 1
H I L L T O P P L A T N 87°01'50" W 183.20'
N 00°43'29" E 305.59'
S 00°38'53" W
305.53'
C. S. M. 1 5 6 6
L O T 2 S 00°
38'53"
W
30
5.54'
10.01'
162.95'
10.24'
Annexation Exhibit
C:\PROJECTS\2026\260514-SCHULTZ_N1807SMAIN\260514-SCHULTZ_N1807SMAINannex.dwg
IRON PIPE FOUND (1 3/8" Outside Diam. unless Noted)
INDICATES RECORDED AS
DISTANCES ARE MEASURED TO THE
LEGEND
( )
NEAREST HUNDREDTH OF A FOOT.
3/4"x18" SOLID IRON ROD SET
1.50Lbs./LINEAL FOOT.
PREPARED BY:
ISTHMUS SURVEYING, LLC
450 NORTH BALDWIN STREET
MADISON, WI 53703
(608) 244.1090
www.isthmussurveying.com
PREPARED FOR:
RYAN SCHULTZ/ARCHITECT
STOUGHTON, WI 53589
2042 BARBER DRIVE
Parcel Contains
To The City of Fort Atkinson, Jefferson County, Wisconsin
C. S. M. 3 9 1 9
L O T 2
C. S. M. 1 5 6 6
L O T 1
L A N D S
L A N D S
55,871 S. F.
1.28 Acres
1 4 1
T O W
N O F K O S H K O N O N G
C I T Y O F F O R T A T K I N S O N
T O W
N O F K O S H K O N O N G
T O W N O F K O S H K O N O N G
Annexation area Description:
Lot 2 and that part of Lot 1, Certified Survey Map No. 1566, recorded in the Office of the Register of Deeds in and for Jefferson County, Wisconsin on
October 5, 1981 in Volume 5 of Certified Survey Maps on Pages 91, 92 and 93, as Document No. 778867, located in the Northeast 1/4 of the
Southeast 1/4 of Section 9, Township 5 North, Range 14 East, Town of Koshkonong, Jefferson County, Wisconsin more particularly described as
follows;
Commencing at the Southeasterly platted boundary corner of said Lot 2, C.S.M. 1566, said point also the point of beginning, thence N 87°01'50" W,
along the southerly platted boundary line of said Lot 2, C.S.M. 1566, 183.20 feet;
thence N 00°43'29" E, along the westerly platted boundary line of said Lot 2 and Lot 1, C.S.M. 1566, 305.59 feet;
thence S 87°00'37" E, 182.79 feet to a point on the westerly right-of-way line of South Main Street and easterly platted boundary line of said Lot 1,
C.S.M. 1566;
thence S 00°38'53" W, along said right-of-way line, and easterly platted boundary line of said Lot 1 and Lot 2, C.S.M. 1566, 305.54 feet to the point of
beginning.
This Annexation area contains 55,871 square feet or 1.28 acres.
Proposed
Annexation
Area
T O W N O F K O S H K O N O N G Point of Commencement
and Beginning
Municipal Boundary line
Annexation/Boundary line
Annexation Area
S 87°00'37" E 182.79'
Page 109 of 271
S T R E E TS O U T H M A I N
JEFFERSON COUNTY ZONE NAD83(11)
WISCONSIN COUNTY COORDINATE SYSTEM
BEARINGS ARE REFERENCED TO THE
60' 0' 60'
C. S. M. 1 5 6 6
L O T 1
H I L L T O P P L A T N 87°01'50" W 183.20'
N 00°43'29" E 305.59'
305.53'
garage
vinyl fence C. S. M. 1 5 6 6
L O T 2
S 00°
38'53"
W
30
5.54'
10.01'
162.95'
10.24'
S 87°00'37" E 182.79'
Well
Residence
Residence
C:\PROJECTS\2026\260514-SCHULTZ_N1807SMAIN\260514-SCHULTZ_N1807SMAINcsm.dwg
IRON PIPE FOUND (1 3/8" Outside Diam. unless Noted)
INDICATES RECORDED AS
DISTANCES ARE MEASURED TO THE
LEGEND
( )
NEAREST HUNDREDTH OF A FOOT.
3/4"x18" SOLID IRON ROD SET
1.50Lbs./LINEAL FOOT.
PREPARED FOR:
RYAN SCHULTZ/ARCHITECT
STOUGHTON, WI 53589
2042 BARBER DRIVE
This C.S.M. Contains
2.5" Outside Diam.
1.5" Outside Diam.
Located In:
Lot 1, except the North 5 feet thereof, and Lot 2, Certified Survey
Map No. 1566, recorded in the Office of the Register of Deeds in
and for Jefferson County, Wisconsin on October 5, 1981 in
Volume 5 of Certified Survey Maps on Pages 91, 92 and 93, as
Document No. 778867, being part of the Northeast 1/4 of the
Southeast 1/4 of Section 9, Township 5 North, Range 14 East,
City of Fort Atkinson, Jefferson County, Wisconsin.
C. S. M. 3 9 1 9
L O T 2
C. S. M. 1 5 6 6
L O T 1
L A N D S
L A N D S
55,871 S. F.
1.28 Acres
1 4 1
N 87°01'50" W 182.86'
N 87°01'50" W 182.97'
N 87°01'50" W 183.07'
76.38'
76.38'
76.38'
76.45'
76.40'
76.38'
76.38'
13,963 S. F.
0.32 Acres
13,960 S. F.
0.32 Acres
13,968 S. F.
0.32 Acres
13,977 S. F.
0.32 Acres
Lot 1
Lot 2
Lot 3
Lot 4
THE EAST LINE OF THE SE 1/4 OF SEC. 9
East 1/4 to the SE 1/4 Corner- S 00°38'53" W
2653.67'
1324.82'
1023.32'
N 87°00'37" W
40.03'
N:523817.64
E:847381.57
T5N, R14E, BEARS S 00°38'53" W
PREPARED BY:
ISTHMUS SURVEYING, LLC
450 NORTH BALDWIN STREET
MADISON, WI 53703
(608) 244.1090
www.isthmussurveying.com
CERTIFIED SURVEY MAP
SHEET 1 OF 3
garage
76.38'
N 87°01'50" W
40.03'
Page 110 of 271
CERTIFIED SURVEY MAP
SURVEYORS CERTIFICATE:
I, Paul A. Spetz, Registered Land Surveyor for Isthmus Survey ing LLC, hereby certify: that under the direction of Jason
W. Schultz, owner, I have surveyed, di vided and mapped the following parcel of land:
Lot 1, except the North 5 feet thereof, and Lot 2, Certified Survey Map No. 1566, recorded in the Office of the Register
of Deeds in and for Jefferson County, Wisconsin on October 5, 1981 in Volume 5 of Certified Survey Maps on Pages
91, 92 and 93, as Document No. 778867, being part of the Northeas t 1/4 of the Southeast 1/4 of Section 9, Township 5
North, Range 14 East, City of Fort Atkinson, Jefferson County, Wisconsin.
This Description contains 55,871 Square feet, or 1.28 Acres.
I further certify that the map on sheet one (1) is a correct representation of the
exterior boundaries of the land surveyed and that I have fully complied with A-E 7,
A-E 7(08) the provisions of Chapter 236.34 of the State Statutes, and the
Land Division Ordinance of the City of Fort Atkinson and in surveying,
dividing, and mapping the same.
Signed this day of , 2026.
SHEET 2 OF 3
Located In:
Lot 1, except the North 5 feet thereof, and Lot 2, Certified Survey Map No. 1566, recorded in the Office of the
Register of Deeds in and for Jefferson County, Wisconsin on October 5, 1981 in Volume 5 of Certified Survey
Maps on Pages 91, 92 and 93, as Document No. 778867, being part of the Northeast 1/4 of the Southeast 1/4 of
Section 9, Township 5 North, Range 14 East, City of Fort Atkinson, Jefferson County, Wisconsin.
Page 111 of 271
OWNERS CERTIFICATE:
I, Jason W. Schultz, owner of the above described land, hereby certify that we have caused the land
described on this Certified Survey Map to be surveyed, divided, mapped and dedicated as represented
on the Map hereon. I further certify that this Certified Survey Map is required by City of Fort Atkinson for
approval.
Witness the hand and seal of said owner this day of , 2026.
By: ,
Jason W. Schultz, owner
State of Wisconsin )
)ss
County of )
Personally came before me this day of , 2026, the above named
Jason W. Schultz, to me known to be the persons who executed the foregoing instrument and
acknowledged the same.
My Commission expires: ;
Notary Public, State of Wisconsin
REGISTER OF DEEDS CERTIFICATE
Received for recording on this day of , 2026, at
o'clock . m. and recorded in recorded in Volume of Certified
Survey Maps on pages , as Document Number .
Staci Hoffman, Jefferson County Register of Deeds
CITY OF FORT ATKINSON PLANNING COMMISSION APPROVAL
Approved by the Planning Commission of the City of Fort Atkinson on this day
of , 2026.
,
printed name signature
SHEET 3 OF 3
CERTIFIED SURVEY MAP
Located In:
Lot 1, except the North 5 feet thereof, and Lot 2, Certified Survey Map No. 1566, recorded in the Office of the
Register of Deeds in and for Jefferson County, Wisconsin on October 5, 1981 in Volume 5 of Certified Survey
Maps on Pages 91, 92 and 93, as Document No. 778867, being part of the Northeast 1/4 of the Southeast 1/4 of
Section 9, Township 5 North, Range 14 East, City of Fort Atkinson, Jefferson County, Wisconsin.
CITY OF FORT ATKINSON CITY COUNCIL APPROVAL
Approved and accepted by the Common Council of the City of Fort Atkinson on this day
of , 2026.
,
printed name signature
Page 112 of 271
PETITION FOR DIRECT ANNEXATION BY UNANIMOUS APPROVAL Pursuant to s. 66.0217(2), Wisconsin
Statutes
PURPOSE
The undersigned, being all of the owners of real property and all of the electors residing in the territory
described herein, hereby petition the City of Fort Atkinson, Jefferson County, Wisconsin, for direct
annexation by unanimous approval pursuant to s. 66.0217(2), Wis. Stats.
TERRITORY TO BE ANNEXED
The territory proposed for annexation is located in the Town of Koshkonong, Jefferson County,
Wisconsin, and is identified by Tax Parcel No. 016-0514-0941-030. The territory encompasses
approximately 1.275 acres.
The legal description of the territory to be annexed is as follows:
Lot 2 and that part of Lot 1, Certified Survey Map No. 1566, recorded in the Office of the
Register of Deeds in and for Jefferson County, Wisconsin on
October 5, 1981 in Volume 5 of Certified Survey Maps on Pages 91, 92 and 93, as Document
No. 778867, located in the Northeast 1/4 of the
Southeast 1/4 of Section 9, Township 5 North, Range 14 East, Town of Koshkonong, Jefferson
County, Wisconsin more particularly described as
follows;
Commencing at the Southeasterly platted boundary corner of said Lot 2, C.S.M. 1566, said
point also the point of beginning, thence N 87°01'50" W,
along the southerly platted boundary line of said Lot 2, C.S.M. 1566, 183.20 feet;
thence N 00°43'29" E, along the westerly platted boundary line of said Lot 2 and Lot 1, C.S.M.
1566, 305.59 feet;
thence S 87°00'37" E, 182.79 feet to a point on the westerly right-of-way line of South Main
Street and easterly platted boundary line of said Lot 1,
C.S.M. 1566;
thence S 00°38'53" W, along said right-of-way line, and easterly platted boundary line of said
Lot 1 and Lot 2, C.S.M. 1566, 305.54 feet to the point of
beginning.
A scale map accurately reflecting the legal description and showing the existing municipal boundary is
attached hereto and incorporated herein by reference.
POPULATION
The population of the territory to be annexed is zero (0).
REQUEST
The undersigned respectfully requests that the City of Fort Atkinson enact an annexation ordinance
incorporating the above-described territory into the City of Fort Atkinson pursuant to s. 66.0217(2), Wis.
Stats.
SIGNATURES
Page 113 of 271
By signing below, the undersigned certifies that they are the owner(s) of all real property within the
territory to be annexed and that this petition is signed for the purpose of direct annexation by
unanimous approval. The undersigned acknowledges that once signed, this petition may not be
withdrawn.
Name (Print) Signature Capacity (Owner/Elector) Date
Jason Schultz Owner
STATE OF WISCONSIN COUNTY OF JEFFERSON
Personally appeared before me this ______ day of __________, 2026, the above-named Jason Schultz,
known to me to be the person who signed this petition, and acknowledged the same.
Notary Public, State of Wisconsin My Commission Expires: __________
Page 114 of 271
City of Fort Atkinson
101 N. Main Street
Fort Atkinson, WI 53538
Apply Online to start immediate
review with the State of Wisconsin
PETITION FOR ANNEXATION
TO THE CITY OF FORT ATKINSON
Address(es) of Property:
Parcel Number(s):
The current population or territory to be annexed and/or attached is persons.
We, the
undersigned, constituting all of the owners of the real property in Jefferson
County, Wisconsin, lying contiguous to the City of Fort Atkinson, respectfully petition the City
Council of the City of Fort Atkinson to annex the territory described and shown on the attached
scale map to the City of Fort Atkinson , Jefferson County, Wisconsin. (Plat of Annexation or
Attachment must include a legal description of the subject property.)
We
the undersigned, elect that this annexation shall take effect to the full extent
consistent with outstanding priorities of other annexation, incorporation or consolidation
proceedings, if any.
We further respectfully request that this property be zoned .
Owner/Petitioner Signature: Print Name: Address: Date:
Personally came before me this day of ____________, _________, the above
named,
(day) (m onth) (year)
to me known to be the persons who executed the
foregoing instrument and acknowledged the same.
Not ary Public, Jefferson County, Wisconsin (SEAL)
My C ommission is permanent or expires on:
Page 115 of 271
Page 116 of 271
Annexation Review Fee Schedule
A Guide for Calculating the Fee Required by ss.16.53 (4) and 66.0217, Wis. Stats.
Required Fees
Th
ere is an initial filing fee and a variable review fee
$300 Initial Filing Fee ( required with the first submittal of all petitions)
$300 – 2 acres or less
$525 – 2.01 acres or more
$300 Review Fee ( required with all annexation submittals except those that consist ONLY of road right-of-way)
$300 – 2 acres or less
$900 – 2.01 to 10 acres
$1,200 – 10.01 to 50 acres
$1,500 – 50.01 to 100 acres
$2,100 – 100.01 to 200 acres
$3,000 – 200.01 to 500 acres
$4,000 – Over 500 acres
$600 TOTAL FEE DUE (Add the Filing Fee to the Review Fee)
Include check or money order, payable to: Department of Administration
DON’T attach the check with staples, tape, …
THE DEPARTMENT WILL NOT PROCESS
AN ANNEXATION PETITION THAT IS NOT ACCOMPANIED
BY THE REQUIRED FEE.
THE DEPARTMENT’S 20-DAY STATUTORY REVIEW PERIOD
COMMENCES UPON RECEIPT OF THE PETITION AND REVIEW FEE
Shaded Area for Office Use Only
Date fee & form received: __________
P
ayer: ______________________________________________________________ Check Number: _________
Check Date: _________
Amount: _________
Page 117 of 271
Page 118 of 271
ORDINANCE NO. ______
AN ORDINANCE ANNEXING
THE TERRITORY ADDRESSED N1807 S. MAIN STREET
TO THE CITY OF FORT ATKINSON
NOW, THEREFORE, The City Council of the City of Fort Atkinson, Wisconsin, does
hereby ordain as follows:
Section 1. TERRITORY ANNEXED. That pursuant to Wis. Stats. §66.0217 of the
Wisconsin Statutes, and the Petition for Annexation filed by the property owners by
unanimous consent, the following described territory in the Town of Koshkonong, Jefferson
County, Wisconsin, is hereby annexed to the City of Fort Atkinson, Wisconsin:
LOT 2 AND THAT PART OF LOT 1, CERTIFIED SURVEY MAP NO. 1566, RECORDED IN THE
OFFICE OF THEREGISTER OF DEEDS IN AND FOR JEFFERSON COUNTY, WISCONSIN ON
OCTOBER 5, 1981 IN VOLUME 5 OF CERTIFIED SURVEY MAPS ON PAGES 91, 92 AND 93,
AS DOCUMENT NO. 778867, LOCATED IN THE NORTHEAST 1/4 OF THESOUTHEAST 1/4
OF SECTION 9, TOWNSHIP 5 NORTH, RANGE 14 EAST, TOWN OF KOSHKONONG,
JEFFERSON COUNTY, WISCONSIN MORE PARTICULARLY DESCRIBED AS FOLLOWS;
COMMENCING AT THE SOUTHEASTERLY PLATTED BOUNDARY CORNER OF SAID LOT 2,
C.S.M. 1566, SAIDPOINT ALSO THE POINT OF BEGINNING, THENCE N 87°01'50" W,
ALONG THE SOUTHERLY PLATTED BOUNDARY LINE OF SAID LOT 2, C.S.M. 1566, 183.20
FEET; THENCE N 00°43'29" E, ALONG THE WESTERLY PLATTED BOUNDARY LINE OF SAID
LOT 2 AND LOT 1, C.S.M.1566, 305.59 FEET; THENCE S 87°00'37" E, 182.79 FEET TO A
POINT ON THE WESTERLY RIGHT-OF-WAY LINE OF SOUTH MAINSTREET AND EASTERLY
PLATTED BOUNDARY LINE OF SAID LOT 1, C.S.M. 1566; THENCE S 00°38'53" W, ALONG
SAID RIGHT-OF-WAY LINE, AND EASTERLY PLATTED BOUNDARY LINE OF SAID LOT 1
AND LOT 2, C.S.M. 1566, 305.54 FEET TO THE POINT OF BEGINNING.
Section 2. EFFECT OF ANNEXATION. From and after the effective date of this
Ordinance the territory described in Section 1 above shall be part of the City of Fort Atkinson
for any and all purposes provided by law and any persons coming or residing within such
territory shall be subject to all Ordinances, rules, and regulations governing the City of Fort
Atkinson.
Section 3. PAYMENT TO THE TOWN OF KOSHKONONG. The property owner has
requested annexation to the City per Wis. Stats. §66.0217(2) – Direct Annexation by
Unanimous Approval. The City of Fort Atkinson agrees to pay the Town of Koshkonong one
Page 119 of 271
lump sum of $1,087.00 to represent the lost Town taxes for the next five years, as required by
Section 66.0217(14) of the Wisconsin Statutes.
Section 4. ZONING CLASSIFICATION. A) The Territory annexed to the City of Fort
Atkinson by this Ordinance is temporarily designated to be part of the following district of the
City for zoning purposes and subject to all provisions of Title 15 of the Code of General
Ordinances in the City of Fort Atkinson entitled “Zoning Ordinance” relating to such district
classifications and to zoning in the City: (SR-5) Single Family Residential-5. B) The boundaries of
these designated districts are established as shown on the map filed in the office of the City
Clerk.
Section 5. WARD DESIGNATION. The territory described in Section 1 of this Ordinance
is hereby made part of Ward 14 of the City of Fort Atkinson, subject to all ordinances, rules,
and regulations of the City. The population of this territory is zero (0) on the effective date of
this Ordinance.
Section 6. SEVERABILITY. If any provision of this Ordinance is found to be invalid or
unconstitutional or if the application of this Ordinance or any person or circumstance is invalid
or unconstitutional such invalidity or unconstitutionality shall not affect the other provisions or
application of this Ordinance which can be given effect without the invalid or unconstitutional
provisions or applications.
Section 7. EFFECTIVE DATE. This Ordinance shall take effect upon passage and
publication and after ____________________, 2026.
Adopted this day of , 2026.
CITY COUNCIL OF THE CITY OF FORT ATKINSON
Kyle Jaeckel, City Council President
ATTEST:
Michelle Ebbert, City Clerk/Treasurer/Finance Director
Page 120 of 271
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
MEMORANDUM
DATE: October 6, 2026
TO: Committee/Commission/Board
FROM: Jedidiah Draeger, Director of Neighborhood and Building Services
RE: Second and possible third/final reading of an Ordinance to Amend Section 18-
256 of the City of Fort Atkinson Code of General Ordinances relating to
Camping Units (Draeger, Director of Neighborhood and Building Services)
BACKGROUND
The City is delegated by the State of Wisconsin to administer and enforce the Wisconsin
Uniform Dwelling Code (UDC) within the City. As part of this delegation, the City is responsible
for issuing building permits, conducting inspections, and enforcing applicable state building
standards for one- and two-family dwellings and certain related structures.
To maintain this delegated authority, municipalities are required to adopt and enforce specific
provisions of the Wisconsin Administrative Code by reference within their local ordinances.
Chapter 18 of the City's Municipal Code, Buildings and Building Regulations, currently adopts
the required state administrative code sections necessary for the administration of the UDC.
The Wisconsin Department of Safety and Professional Services (DSPS) has since adopted SPS
327 relating to Camping Units, as part of the applicable administrative code. Updating Chapter
18 to include SPS 327 ensures that the City's ordinances remain consistent with current state
law and continue to satisfy the requirements of the City's delegated enforcement authority. SPS
327 is included with this staff report for information and review.
DISCUSSION
The proposed ordinance amendment adopts Wisconsin Administrative Code SPS 327, Camping
Units, by reference into Chapter 18 of the City's Municipal Code. This amendment is
administrative in nature and is intended to ensure that the City's building regulations remain
consistent with current state requirements governing the Uniform Dwelling Code program.
Under Wisconsin law, municipalities that elect to administer the Uniform Dwelling Code are
required to adopt the applicable administrative code provisions identified by the Department of
Safety and Professional Services. Adoption of SPS 327 is part of maintaining compliance with
the State's delegation requirements and preserving the City's authority to issue permits,
perform inspections, and enforce the Uniform Dwelling Code locally.
Page 121 of 271
SPS 327 establishes statewide construction and safety standards applicable to camping units.
Incorporating these standards by reference provides consistency between state and local
regulations and allows the City to administer building-related matters using the most current
state standards.
Importantly, adoption of SPS 327 does not allow camping units to be permitted within the City.
The proposed ordinance does not amend zoning regulations, land use policies, or occupancy
provisions. Camping units will continue to be allowed only in locations and under circumstances
otherwise authorized by the City's zoning ordinance and other applicable municipal regulations.
The amendment simply adopts the applicable state construction and safety standards required
under the City's delegated building inspection authority. It is also important to note that
Camping Units are not the same as Accessory Dwelling Units which are a different type of land
use and are not regulated by the SPS 327.
Camping Units vs. Accessory Dwelling Units
Camping Unit Accessory Dwelling Unit
(ADU)
Purpose Portable, temporary shelter for recreational/camping
use
Permanent residential
dwelling
Structure Portable and highway-ready (e.g., camper, motor
home, tent, bus, van, or similar vehicle)
Permanent attached or
detached dwelling
Current City
Status
Permitted only within approved campgrounds as a
conditional use; prohibited as living quarters outside
of approved campgrounds
Not permitted in any zoning
district
Length of
Stay
Limited to 180 consecutive days at an approved
campground, after which the unit must be removed
for at least 24 hours
Intended for long-term or
permanent occupancy
Private
Property
May be stored/parked on private property subject to
applicable parking regulations, but may not be used
for habitation or sleeping
Cannot currently be
established or occupied as a
residential dwelling
Key Distinction: A camping unit is regulated as a temporary recreational shelter and is not
permitted to function as a dwelling on a private residential lot. An ADU is, by definition, a
permanent residential dwelling located on the same lot as a principal dwelling. Under the City's
Page 122 of 271
current zoning regulations, neither may be used as a residential living unit on a private
residential lot.
Failure to update the City's ordinances to reflect the current Wisconsin Administrative Code
could create inconsistencies between local and state regulations and may jeopardize the City's
continued compliance with the requirements necessary to administer the Uniform Dwelling
Code program.
The Ordinance Committee reviewed the proposed Ordinance Amendment to Section 18-256 at
a meeting on July 21, 2026, and recommended the City Council adopt the proposed
Amendment.
FINANCIAL ANALYSIS
The proposed ordinance amendment is not expected to have a significant fiscal impact on the
City. Adoption of SPS 327 is an administrative update required to maintain compliance with
state requirements associated with the City's delegated Uniform Dwelling Code authority.
Any implementation costs are expected to be minimal and will be absorbed within the Building
Inspection Department's existing operations. Maintaining delegated authority allows the City to
continue issuing permits and performing inspections locally, providing efficient service to
residents and avoiding the potential administrative and operational impacts that could result if
the City were no longer authorized to administer the Uniform Dwelling Code.
RECOMMENDATION
The first reading was held by the City Council on September 15, 2026. Staff recommends the
City Council hold the second reading, suspend the rules to hold a third/final reading, and adopt
the ordinance amending Section 18-256 of the City of Fort Atkinson General Code of
Ordinances relating to Camping Units.
ATTACHMENTS
1. DRAFT ORDINANCE NO_Camping Units
2. WI SPS 327
3. ORDINANCE NO UDC Camping Units 10.6.26 Final
Page 123 of 271
ORDINANCE NO. ____
AN ORDINANCE TO AMEND SECTION 18-256
OF THE CITY OF FORT ATKINSON CODE OF GENERAL ORDINANCES RELATING TO
CAMPING UNITS
NOW THEREFORE, the City Council of the City of Fort Atkinson, Wisconsin, does hereby
ordain as follows:
Section 1. Amends Sec. 18-256. – Adoption of Uniform Dwelling Code to read as follows:
Sec. 18-256. – Adoption of Uniform Dwelling Code.
(a) Pursuant to Wis. Stats. §§ 101.65, and 101.66, the council ordains a building
code for new one- and two-family dwellings, accessory structures and the
remodeling of, or addition to existing structures, by adoption of Wis. Admin.
Code chapters:
SPS. 320 Administration and Enforcement;
SPS. 321 Construction Standards;
SPS. 322 Energy Conservation;
SPS. 323 Heating, Ventilating and Air Conditioning;
SPS. 324 Electrical Standards;
SPS. 325 Plumbing and Potable Water Standards
SPS. 327 Camping Units
Section 2. This ordinance shall take effect after passage, posting, or publication as provided
by law.
Enacted by the City Council of the City of Fort Atkinson, Jefferson County, Wisconsin,
this __________ day of ____________, 2026.
Page 124 of 271
Fort Atkinson City Council
______________________________________
Kyle Jaeckel, President
ATTEST:
____________________________________________________
Michelle Ebbert, City Clerk/Treasurer/Finance Director
Page 125 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
1 SAFETY AND PROFESSIONAL SERVICES SPS 327.02
Chapter SPS 327
CAMPING UNITS
Subchapter I — Administration and Enforcement
SPS 327.01 Purpose.
SPS 327.02 Scope.
SPS 327.03 Effective date.
SPS 327.04 Applications.
SPS 327.05 Exemptions.
SPS 327.06 Procedure for municipalities.
SPS 327.07 State jurisdiction.
SPS 327.08 Definitions.
SPS 327.09 Wisconsin camping unit building permit.
SPS 327.10 Procedure for obtaining camping unit building permit.
SPS 327.11 Inspections.
SPS 327.12 Approval procedures.
SPS 327.13 Suspension or revocation of Wisconsin camping unit building
permit.
SPS 327.14 Effect of suspension and revocation.
SPS 327.15 Approval of products.
SPS 327.16 Petition for variance.
SPS 327.17 Municipal variance from the code.
SPS 327.18 Appeals of orders, determinations, and for extension of time.
SPS 327.19 Adoption of standards.
Subchapter II — Construction Standards
SPS 327.20 Loads and materials.
SPS 327.21 Exits.
SPS 327.22 Stairways and elevated areas.
SPS 327.23 Ladders.
SPS 327.24 Ceiling height.
SPS 327.25 Fireblocking.
SPS 327.26 Smoke detectors.
SPS 327.27 Carbon monoxide alarms.
SPS 327.28 Protection against decay and termites.
SPS 327.29 Floor design.
SPS 327.30 Wood floors in contact with the ground.
SPS 327.31 Wood frame floors.
SPS 327.32 Decks.
SPS 327.33 Exterior covering.
SPS 327.34 Wood frame walls.
SPS 327.35 Roof design and framing.
SPS 327.36 Weather protection for roofs.
Subchapter III — Heating, Ventilating, and Air Conditioning
SPS 327.37 Scope.
SPS 327.38 Design.
SPS 327.39 Selection of equipment.
SPS 327.40 Types and location of equipment.
SPS 327.41 Combustion air.
SPS 327.42 Mechanical draft systems.
SPS 327.43 Equipment maintenance information.
SPS 327.44 Ductwork.
SPS 327.45 Dampers, registers, and grilles.
SPS 327.46 Piping.
SPS 327.47 Venting system location.
SPS 327.48 Multiple appliance venting.
SPS 327.49 Fuel storage.
Subchapter IV — Electrical Standards
SPS 327.50 Electrical standards.
Subchapter V — Plumbing
SPS 327.51 Plumbing.
Subchapter VI — Camping Unit Transfer Tanks
SPS 327.52 Purpose.
SPS 327.53 Installation and maintenance.
SPS 327.54 Compliance with code.
SPS 327.55 Servicing requirements.
SPS 327.56 Abandonment.
SPS 327.57 Penalties.
Note: Ch. SPS 327 was created by emergency rule, EmR1703, effective February
6, 2017.
Subchapter I — Administration and Enforcement
SPS 327.01 Purpose. The purpose of this code is to es-
tablish uniform statewide construction standards and inspection
procedures for camping units in accordance with the require-
ments of ss. 101.63 (1), 101.82 (1), and 145.02 (2) (b), Stats.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.02 Scope. (1) GENERAL. The provisions of
this code apply to all camping units for which construction com-
menced on or after February 6, 2017.
Note: Also see s. SPS 327.04.
(2) MUNICIPAL ORDINANCES. (a) A municipality may not
adopt an ordinance on any subject falling within the scope of this
code including establishing restrictions on the occupancy of
camping units for any reason other than noncompliance with the
provisions of this code as set forth in s. SPS 327.11 (5) . This
code does not apply to occupancy requirements occurring after
the first occupancy following the final inspection required under
s. SPS 327.11 (4).
(b) This code shall not be construed to affect local require-
ments relating to land use, zoning, post-construction storm water
management, fire districts, side, front and rear setback require-
ments, property line requirements or other similar requirements.
This code shall not affect the right of municipalities to establish
safety regulations for the protection of the public from hazards at
the job site.
(c) Any municipality may, by ordinance, require permits and
fees for any construction, additions, alterations, or repairs not
within the scope of this code.
(d) Any municipality may, by ordinance, adopt the provisions
of this chapter to apply to any additions or alterations to existing
camping units.
(e) Nothing in this chapter shall prevent a municipality from
any of the following:
1. Implementing erosion and sediment control requirements
that are more stringent than the standards of this code when di-
rected by an order of the United States Environmental Protection
Agency or by an administrative rule of the department of natural
resources under s. NR 151.004.
2. Regulating erosion and sediment control for sites that are
not under the scope of this chapter.
(f) This code shall not be construed to affect the authority of
the department of natural resources to enforce chs. 281 and 283,
Stats., and administrative rules promulgated thereunder.
(3) LEGAL RESPONSIBILITY. The department or the munici-
pality having jurisdiction shall not assume legal responsibility for
the design or construction of camping units.
(4) RETROACTIVITY. The provisions of this code are not
retroactive, except as specifically stated in a rule.
(5) LANDSCAPING. The scope of this code does not extend to
driveways, sidewalks, landscaping, and other similar features not
having an impact on the camping unit structure.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18; correction in (2) (f) made under s. 35.17, Stats., Register March
2018 No. 747.
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 126 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.03 WISCONSIN ADMINISTRATIVE CODE 2
SPS 327.03 Effective date. The effective date of this
chapter is February 6, 2017.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.04 Applications. (1) NEW CAMPING UNITS.
This code applies to all camping units for which construction
commenced on or after February 6, 2017. All camping units cov-
ered under this subsection shall meet the requirements of this
chapter. If a plumbing, electrical, heating, or air conditioning sys-
tem is installed in a camping unit, the system shall meet the re-
quirements of this chapter.
(2) ADDITIONS AND ALTERATIONS. Additions and alterations
to camping units covered by this code shall comply with all provi-
sions of this code at the time of permit application or the begin-
ning of the project, if no permit is required.
(3) CHANGE OF USE. Property previously used for another
purpose shall comply with this code upon conversion to a camp-
ing unit.
Note: Examples of property that may be converted to a camping unit include a
cabin, covered wagon, or gazebo.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.05 Exemptions. (1) EXISTING CAMPING
UNITS. The provisions of this code shall not apply to camping
units, the construction of which was commenced prior to Febru-
ary 6, 2017, or to additions or alterations to such camping units.
Note: As provided under s. SPS 327.02 (2) (d), the provisions of this chapter may
be adopted by a municipality to apply to any additions or alterations to existing
camping units.
(2) REPAIRS. The provisions of this code do not apply to re-
pairs or maintenance to camping units, or to the repair of electri-
cal, plumbing, heating, ventilating, air conditioning and other sys-
tems installed therein.
(3) ACCESSORY BUILDINGS. The provisions of this code do
not apply to detached garages or to any accessory buildings de-
tached from the camping unit.
(4) DETACHED DECKS. The provisions of this code do not ap-
ply to detached decks provided the deck does not serve an exit
from the camping unit.
(5) MANUFACTURED AND MODULAR HOMES. The provisions
of this code do not apply to manufactured homes and modular
homes.
(6) MOTOR AND MOBILE HOMES AND RECREATIONAL VEHI-
CLES. The provisions of this code do not apply to motor homes,
recreational vehicles, park model recreational vehicles, and recre-
ational mobile homes.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.06 Procedure for municipalities. (1) MU-
NICIPAL JURISDICTION. (a) General. 1. Except as provided in
par. (b), cities, villages, towns, and counties approved by the de-
partment under s. SPS 320.06 to exercise jurisdiction over the
construction and inspection of new dwellings shall exercise juris-
diction over the construction and inspection of new camping
units.
2. Municipalities exercising jurisdiction under subd. 1. shall,
by ordinance, adopt this code in its entirety.
3. Except as provided under s. SPS 327.02 (2) (d), no addi-
tional requirements within the scope of this code may be adopted
by a municipality unless approved by the department in accor-
dance with s. SPS 327.17.
(b) Intent to not exercise jurisdiction. Municipalities intend-
ing not to exercise jurisdiction over the construction and inspec-
tion of new camping units shall notify the department, in writing,
within 90 days of the effective date of this code.
(c) Recision of ordinances. Municipalities that rescind an or-
dinance under par. (a) shall file a certified copy of the recision
with the department within 30 days of adoption.
Note: Notification of intent to not exercise jurisdiction and certified copies of re-
cisions of ordinances should be sent to Department of Safety and Professional Ser-
vices, Industry Services Division, PO Box 2658, Madison, WI 53701-2658.
(2) DEPARTMENTAL JURISDICTION. In municipalities not ex-
ercising jurisdiction under sub. (1), the department will oversee
enforcement and inspection services for new camping units.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.07 State jurisdiction. In accordance with s.
101.64 (1) (h), Stats., municipalities administering the code may
be monitored by the department for compliance with the admin-
istrative requirements under this code.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18; correction made under s. 13.92 (4) (b) 7., Stats., Register May
2018 No. 749.
SPS 327.08 Definitions. In this chapter:
(1) XAccessory building Y means a detached building, not
used as a camping unit but is incidental to that of the camping
unit and which is located on the same lot. Accessory building
does not mean farm building.
(2) XAdditionY means new construction performed on a
camping unit which increases the outside dimensions of the
camping unit.
(3) XAllowable stressY means the specified maximum per-
missible stress of a material expressed in load per unit area.
(4) XAlterationY means an enhancement, upgrading, or sub-
stantial change or modification other than an addition or repair to
a camping unit or to electrical, plumbing, heating, ventilating, air
conditioning, and other systems within a camping unit.
(5) XApprovedY means an approval by the department or its
authorized representative. Approval is not to be construed as an
assumption of any legal responsibility for the design or construc-
tion of the camping unit.
(6) XBuilding componentY means any subsystem, subassem-
bly, or other system designed for use in or as part of a structure,
which may include structural, electrical, mechanical, plumbing,
and fire protection systems and other systems affecting health and
safety.
(7) XBuilding systemY means plans, specifications and docu-
mentation for a system of manufactured building or for a type or
a system of building components, which may include structural,
electrical, mechanical, plumbing, and variations which are sub-
mitted as part of the building system.
(8) XCampgroundY has the meaning given in s. ATCP 79.03
(3).
Note: ATCP 79.03 (3) reads: XCampgroundY means a parcel or tract of land
owned by a person, state, or local government that is designed, maintained, in-
tended, or used for the purpose of providing campsites offered with or without
charge, for temporary overnight sleeping accommodations.
(9) XCamping unit Y means a framed structure or a tent,
teepee, yurt, or other structure with fabric roof or walls that is
400 square feet or less in area, which is placed by a campground
owner or operator in a campground for which a permit is issued
under s. 97.67, Stats., and used for seasonal overnight camping.
(10) XCamping unit transfer tankY or Xtransfer tankY means a
type of portable container used to collect and hold wastewater
discharges generated by an individual camping unit.
(11) XCeiling heightY means the clear vertical distance from
the finished floor to the finished ceiling.
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 127 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
3 SAFETY AND PROFESSIONAL SERVICES SPS 327.08
(12) XCertified UDC inspectorY means a person certified by
the department to engage in the administration and enforcement
of this code.
(13) A XchimneyY is one or more vertical, or nearly so, pas-
sageways or flues for the purpose of conveying flue gases to the
atmosphere.
(14) XCodeY means this chapter.
(15) XCommon areaY means a kitchen, hallway, or any habit-
able room.
(16) XCooling loadY is the rate at which heat must be removed
from the space to maintain a selected indoor air temperature dur-
ing periods of design outdoor weather conditions.
(17) XDeckY means an unenclosed exterior structure, at-
tached or adjacent to the exterior wall of a camping unit, which
has a floor, but no roof.
(18) XDepartmentY means the department of safety and pro-
fessional services.
(19) XDilution airY means air that is provided for the purpose
of mixing with flue gases in a draft hood or draft regulator.
(20) XDirect-vent applianceY means a gas-burning appliance
that is constructed and installed so that all air for combustion is
derived directly from the outside atmosphere and all flue gases
are discharged to the outside atmosphere.
(21) XExitY means a direct, continuous, unobstructed means
of egress from inside the camping unit to the exterior of the
camping unit.
(22) XFireblockingY means a material or device used to retard
or prevent the spread of flame or hot gases through concealed
spaces into adjacent rooms or areas.
(23) XFirst floor Y means the first floor level above any
groundfloor or basement or, in the absence of a groundfloor or
basement, means the lowest floor level in the camping unit.
(24) XFlightY means a continuous series of risers and treads,
with no intermediate landings.
(25) XGas applianceY means any device that uses gas as a fuel
or raw material to produce light, heat, power, refrigeration, or air
conditioning.
(26) XGroundfloorY means that level of a camping unit, be-
low the first floor, located on a site with a sloping or multilevel
grade and which has a portion of its floor line at grade.
(27) XGuardY means a barrier erected to prevent a person
from falling to a lower level.
(28) XHabitable room Y means any room used for sleeping,
living, or dining purposes, excluding such enclosed places as
kitchens, closets, pantries, bath or toilet rooms, hallways, laun-
dries, storage spaces, utility rooms, and similar spaces.
(29) XHandrailY means a horizontal or sloping rail intended
for grasping by a hand, for guidance or support or preventing a
fall down a stair.
(30) XHeating loadY is the estimated heat loss of each room or
space to be heated, based on maintaining a selected indoor air
temperature during periods of design outdoor weather conditions.
The total heat load includes: the transmission losses of heat trans-
mitted through the wall, floor, ceiling, glass or other surfaces;
and either the infiltration losses or heat required to warm outdoor
air used for ventilation.
(31) XHV ACY means heating, ventilating and air
conditioning.
(32) XHV AC systemY means the equipment, distribution net-
work, and terminals that provide either collectively or individu-
ally the processes of heating, ventilating, or air conditioning to a
building.
(33) XInsigniaY or XWisconsin insigniaY means a device or
seal approved by the department to certify compliance with this
code.
(34) XKitchenY means an area used, or designed to be used,
for the preparation of food.
(35) XLand disturbing construction activityY means any man-
made alteration of the land surface resulting in a change in the to-
pography or existing vegetative or non-vegetative soil cover, that
may result in storm water runoff and lead to an increase in soil
erosion and movement of sediment.
(36) XLandingY means the level portion of a stairs located be-
tween flights of stairs or located at the top and base of a stairs.
(37) XLavatoryY means a sink or basin in a camping unit
bathroom.
(38) XListed and listingY means equipment or building com-
ponents which are tested by an independent testing agency and
accepted by the department.
(39) XLoftY means an upper room or floor with one side that
has at least 50% of the space from the floor to the ceiling open to
the floor below.
(40) XManufactured home Y has the meaning given in s.
101.91 (2), Stats.
(41) XMechanical draft systemY means a venting system for a
gas burning appliance that is designed to remove flue or vent
gases by mechanical means, such as a fan, which may consist of
an induced draft portion under non-positive static pressure or a
forced draft portion under positive static pressure.
(42) XModular homeY has the meaning given in s. 101.71 (6),
Stats.
(43) XMotor home Y has the meaning given in s. 340.01
(33m), Stats.
(44) XMunicipalityY means any city, village, town, or county
in this state.
(45) XNaturally vented applianceY means an appliance with a
venting system designed to remove flue or vent gases under non-
positive static vent pressure entirely by natural draft.
(46) XOwnerY means any person having a legal or equitable
interest in the camping unit.
(47) XPark model recreational vehicleY means a factory built
vehicular structure that is designed only for recreational use and
not as a primary residence or for permanent occupancy, is built
and certified in accordance with the National Fire Protection As-
sociation[s NFPA 1192-15, Standard for Recreational Vehicles,
or the American National Standards Institute[s ANSI A119.5-15,
Recreational Park Trailer Standard, and is not certified as a man-
ufactured home.
(48) XPorchY means an unenclosed exterior structure at or
near grade attached or adjacent to the exterior wall of any camp-
ing unit, and having a roof and floor.
(49) XPre-existing insigniaY or XWisconsin pre-existing in-
signiaY means a device or seal approved by the department for
camping units, the construction of which was commenced prior
to February 6, 2017.
(50) XRecreational mobile homeY has the meaning given in s.
66.0435 (1) (hm), Stats.
(51) XRecreational vehicle Y has the meaning given in s.
340.01 (48r), Stats.
(52) XRegistered UDC inspection agency Y means a person,
business, or entity that is registered with the department for the
purpose of facilitating issuance of Wisconsin camping unit build-
ing permits and inspection of camping units in municipalities
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 128 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.08 WISCONSIN ADMINISTRATIVE CODE 4
where the department has jurisdiction pursuant to s. 101.651 (3)
(b), Stats.
(53) XRepairY means the act or process of restoring to origi-
nal soundness, including redecorating, refinishing, nonstructural
repairs or maintenance, or the replacement of existing fixtures,
systems, or equipment with the equivalent fixture, system or
equipment.
(54) XShingleY means a unit of roof-covering material that
has been manufactured to specific dimensions and is applied in
overlapping fashion. XShingleY includes all of the following:
(a) XFiberglass asphalt shingleY means a type of shingle with
an internal mat composed of nonwoven, resin-bonded glass
fibers, that is impregnated and coated with asphalt.
(b) XLaminated shingleY means a shingle with a second layer
of asphalt and mat laminated to the first layer, usually in a design
pattern to simulate the dimensional appearance of natural slate or
wood shakes.
(c) XOrganic asphalt shingleY means a shingle with an internal
mat composed of organic fibers, such as cellulose, that is satu-
rated and coated with asphalt.
(d) XStrip shingleY means a rectangular shingle that relies ei-
ther on a sealant or on a combination of weight and stiffness to re-
sist wind uplift, rather than using interlocking tabs.
(55) XStair,Y Ystairs,Y or YstairwayY means one or more risers
that form a continuous passage from one elevation to another.
(56) A XstoryY is that portion of a camping unit located be-
tween the floor and the ceiling.
(57) XVentY means a vertical flue or passageway to vent fuel-
burning appliances.
(58) XVentilationY means the process of supplying or remov-
ing air by natural or mechanical means to or from any space.
(59) XWater closetY means a water-flushed plumbing fixture
designed to receive human excrement directly from the user of
the fixture.
(60) XWaters of the state Y includes those portions of Lake
Michigan and Lake Superior within the boundaries of Wisconsin,
and all lakes, bays, rivers, streams, springs, ponds, wells, im-
pounding reservoirs, marshes, watercourses, drainage systems,
and other surface waters or groundwaters, natural or artificial,
public or private, within the state or its jurisdiction.
(61) XWindowY means a glazed opening in an exterior wall,
including glazed portions of doors, within a conditioned space.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.09 Wisconsin camping unit building per-
mit. (1) WHERE REQUIRED. A Wisconsin camping unit build-
ing permit shall be obtained from the municipality administering
and enforcing this code or from a registered UDC inspection
agency administering and enforcing this code in a municipality
where the department has jurisdiction pursuant to s. 101.651 (3)
(b), Stats., before any construction of a camping unit may begin.
(2) INSPECTIONS. A person who obtains a Wisconsin camp-
ing unit building permit from a registered UDC inspection
agency shall retain the same agency to conduct the inspection of
the camping unit under s. SPS 327.11.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.10 Procedure for obtaining camping unit
building permit. (1) APPLICATION. Application for a Wis-
consin camping unit building permit shall be on forms obtained
from the department, the municipality, or the authorized UDC in-
spection agency administering and enforcing this code. No appli-
cation shall be accepted that does not contain all the information
requested on the form.
Note: Applications are available from the department by email at dsps@wiscon-
sin.gov or by telephone at (608) 266-2112, (877) 617-1565, or 411 (Telecommuni-
cations Relay).
(2) FILING OF PERMIT APPLICATIONS. A Wisconsin camping
unit building permit shall be filed with the municipality or the
authorized UDC inspection agency administering and enforcing
this code.
(3) FEES. (a) Municipal fees. The municipality shall, by or-
dinance, determine fees to cover expenses of final inspection of
the camping unit and the issuance of a Wisconsin insignia.
Note: Also see s. SPS 302.34, which sets the fee the department will charge for
a Wisconsin insignia.
(b) Inspection agency fees. UDC inspection agency fees shall
be determined by contract between the municipality and the
agency or between the department and the agency, where the
agency has been authorized to conduct inspections on behalf of
the department.
(4) ISSUANCE OF PERMITS. (a) The Wisconsin camping unit
building permit shall be issued if the requirements for filing and
fees are satisfied.
(b) The permit shall expire 24 months after issuance if con-
struction of the camping unit has not been completed.
(5) DENIAL OF PERMITS. (a) General. Approval shall be de-
nied if the municipality or authorized UDC inspection agency ad-
ministering and enforcing this code determines that the Wiscon-
sin camping unit building permit application does not substan-
tially conform to the provisions of this code and other legal
requirements.
(b) Denial of application. A copy of the denied application,
accompanied by a written statement specifying the reasons for
denial, shall be sent to the applicant and to the owner as specified
on the Wisconsin camping unit building permit application.
(c) Appeals. The applicant may appeal a denial of the appli-
cation in accordance with the procedure outlined in s. SPS
327.18.
(6) TIME-SPAN FOR APPROVAL OR DENIAL. Action to approve
or deny a camping unit building permit application shall be com-
pleted within 10 business days of receipt of the application, fees,
and supplementary information required to process the
application.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.11 Inspections. (1) INSPECTOR CERTIFICA-
TION. All inspections, for the purpose of administering and en-
forcing this code, shall be performed by a certified UDC inspec-
tor who holds the respective credential for the inspection
performed.
Note: Also see ch. SPS 305 , which relates to licenses, certifications, and
registrations.
(2) GENERAL INSPECTION REQUIREMENTS. (a) General.
Camping units for which a permit has been issued under s. SPS
327.10 (4) shall be inspected in accordance with this section. In-
spections shall be conducted by the municipality or authorized
UDC inspection agency administering and enforcing this code to
determine if the construction conforms to the provisions of this
code.
(b) Inspection notice. The applicant or an authorized repre-
sentative shall request an inspection required under sub. (3) or (4)
from the municipality or authorized UDC inspection agency ad-
ministering and enforcing this code.
(3) ROUGH INSPECTION. (a) A rough inspection of the fol-
lowing shall be performed after the rough work is constructed but
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 129 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
5 SAFETY AND PROFESSIONAL SERVICES SPS 327.14
before it is concealed to determine if the work complies with this
code:
1. General construction, including framing.
2. Rough electrical.
3. Rough plumbing.
4. Rough heating, ventilating and air conditioning.
(b) All rough work may be completed before the notice for
rough inspection is given, provided the rough work has not been
covered.
(c) The applicant may request one rough inspection or indi-
vidual rough inspections.
(d) A separate fee may be charged for each individual
inspection.
(4) FINAL INSPECTION REQUIRED PRIOR TO OCCUPANCY. (a)
A camping unit may not be occupied until a final inspection has
been made of a camping unit [s construction, HV AC, electrical,
plumbing, and transfer tank that finds no critical violations of this
code that could reasonably be expected to affect the health or
safety of a person using the camping unit.
(b) If the municipality or authorized UDC inspection agency
conducting the inspection under this subsection did not conduct
the inspection under sub. (3), the final inspection under this sub-
section may not take place until the municipality or authorized
UDC inspection agency is provided a copy of an inspection report
or other written verification of a pass result for all inspections re-
quired under sub. (3).
(5) NOTICE OF COMPLIANCE OR NONCOMPLIANCE. (a) Upon
a finding of compliance for an inspection under sub. (4), the mu-
nicipality shall assign a Wisconsin insignia to the owner of the
camping unit as provided in s. SPS 327.12 (1).
(b) Upon a finding of noncompliance for an inspection under
sub. (3) or (4), the municipality or authorized UDC inspection
agency enforcing this code shall notify the applicant of record
and the owner, in writing, of the violations to be corrected.
(c) The municipality or authorized UDC inspection agency
shall order all cited violations corrected within 30 days after writ-
ten notification, unless an extension of time is granted under s.
SPS 327.18.
(6) VOLUNTARY INSPECTION. The department or its autho-
rized representative may, at the request of the owner, enter and in-
spect camping units, subject to the provisions of this code, to as-
certain compliance with this code.
(7) RECORD KEEPING. (a) Municipal enforcement. Munici-
palities that have adopted an ordinance to enforce this code shall
maintain records in accordance with all of the following:
1. A record shall be made of each visit to a site, each inspec-
tion performed, and the pass or fail results of each inspection.
2. Application forms, correction orders, correspondence and
inspection records shall be maintained for 7 years after comple-
tion of the camping unit.
(b) State enforcement. Inspectors working under state con-
tract shall maintain records in accordance with the provisions of
the contract that was in effect at the time the inspections were
completed.
Note: Records generated by an inspection are public records and are subject to
the open-records law.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.12 Approval procedures. (1) WISCONSIN
INSIGNIA. (a) Upon a finding of compliance under s. SPS 327.11
(5) (a), the municipality shall issue a Wisconsin insignia to the
owner of the camping unit.
(b) At the request of the owner of a camping unit that is ex-
empt from the provisions of this code under s. SPS 327.05 (1) ,
the municipality shall issue a Wisconsin pre-existing insignia to
the owner of the camping unit. A pre-existing insignia shall con-
tain the following language: XUnit was constructed before code[s
eff. date.Y
(c) Wisconsin insignias shall be purchased by municipalities
from the department in accordance with the fee established in s.
SPS 302.34. The owner of the camping unit shall affix the Wis-
consin insignia to the camping unit as provided in sub. (4).
(2) UNIT IDENTIFICATION. Each camping unit shall be as-
signed a serial number. The serial number shall be located on the
Wisconsin insignia.
(3) LOST OR DAMAGED INSIGNIA. (a) Notification. If a Wis-
consin insignia becomes lost or damaged or is no longer in use,
the owner of the camping unit shall immediately notify the mu-
nicipality in writing.
(b) Return of damaged insignias. If a Wisconsin insignia be-
comes damaged, the owner of the camping unit shall return the
insignia to the municipality with the appropriate fee to obtain a
new insignia.
(4) AFFIXING W ISCONSIN INSIGNIAS. Each Wisconsin in-
signia shall be affixed to a specific camping unit in an overt loca-
tion on the outside or inside of the camping unit. If the Wisconsin
insignia is issued under sub. (1) (a), the camping unit may not be
occupied until the Wisconsin insignia has been affixed as pro-
vided in this subsection.
(5) INSIGNIA RECORDS. (a) Municipality[s insignia records.
The municipality shall keep permanent records regarding the
handling of all Wisconsin insignias indicating the following:
1. The number of Wisconsin insignias affixed to camping
units.
2. Which Wisconsin insignia has been applied to which
camping unit.
3. The disposition of any damaged or rejected Wisconsin
insignias.
4. The location and custody of all unused Wisconsin
insignias.
(b) Retention of insignia records. The records under par. (a)
shall be maintained by the municipality for at least 10 years. A
copy of the records shall be sent to the department upon request.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.13 Suspension or revocation of Wiscon-
sin camping unit building permit. (1) (a) The municipal-
ity or the registered UDC inspection agency administering and
enforcing this code may suspend or revoke any Wisconsin camp-
ing unit building permit where it appears that the permit or ap-
proval was obtained through fraud or deceit, where the applicant
has willfully refused to correct a violation order, or where the in-
spector is denied access to the premises.
(b) No construction may take place on the camping unit after
suspension or revocation of the permit.
(2) Any person aggrieved by a determination made by the de-
partment, a municipality, or a registered UDC inspection agency
may appeal the decision in accordance with s. SPS 327.18.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.14 Effect of suspension and revocation.
(1) BEARING OF INSIGNIA. Upon suspension or revocation under
s. SPS 327.13, the camping unit shall not be entitled to bear the
Wisconsin insignia and the camping unit may not be occupied un-
less the municipality has inspected, or caused to be inspected,
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 130 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.14 WISCONSIN ADMINISTRATIVE CODE 6
such camping unit and is satisfied that all requirements for ap-
proval have been met.
(2) RETURN OF INSIGNIAS. The owner shall return to the mu-
nicipality a Wisconsin insignia assigned to a camping unit no
later than 30 days from the effective date of any suspension or re-
vocation under s. SPS 327.13.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.15 Approval of products. (1) VOLUNTARY
APPROVAL. (a) Materials, equipment and products regulated by
this code may receive a written approval from the department in-
dicating code compliance.
(b) 1. Approval of materials, equipment and products shall be
based on sufficient data, tests and other evidence that prove the
material, equipment or product is in compliance with the stan-
dards specified in this code.
2. Tests, compilation of data, and calculations for materials,
equipment and products shall be conducted by a qualified inde-
pendent third party.
(2) ALTERNATE APPROVAL. (a) Materials, equipment and
products, including experimental materials, equipment, and
products, which meet the intent of this code and which are not ap-
proved under sub. (1) shall be permitted if approved in writing by
the department.
(b) 1. Approval of materials, equipment and products shall be
based on sufficient data, tests, and other evidence that prove the
material, equipment, or product meets the intent of the standards
specified in this code.
2. Tests, compilation of data, and calculations for materials,
equipment, and products shall be conducted by a qualified inde-
pendent third party.
(3) REVIEW, APPROVAL AND REVOCATION PROCESSES. (a) 1.
Upon receipt of a fee and a written request, the department may
issue an approval for a material, equipment, or product.
2. The department shall review and make a determination on
an application for approval after receipt of all forms, fees, plans,
and information required to complete the review.
3. For voluntary and alternate approvals, a determination
shall be made within 40 business days of receipt of all required
materials.
(b) 1. The department may include specific conditions in is-
suing an approval, including an expiration date for the approval.
2. Violations of the conditions under which an approval is is-
sued shall constitute a violation of this code.
(c) If the department determines that the material, equipment,
or product does not comply with this code or the intent of this
code, the request for approval shall be denied in writing.
(d) If an approved material, equipment, or product is modi-
fied, the approval shall be considered null and void, unless the
material, equipment, or product is resubmitted to the department
for review and approval is granted.
(e) 1. The department may revoke or deny an approval of a
material, equipment, or product for any false statements or mis-
representations of relevant facts or data, unacceptability of a third
party providing information, or as a result of material, equip-
ment, or product failure.
2. The department may re-examine an approved material,
equipment, or product and issue a revised approval at any time.
(f) The department may revoke an approval if the department
determines that the material, equipment, or product does not
comply with this code or the intent of this code due to a change in
the code or department interpretation of the code.
(g) An approval issued by the department may not be con-
strued as an assumption of any responsibility for defects in de-
sign, construction, or performance of the approved material,
equipment, or product nor for any damages that may result.
(h) Fees for the review of a material, equipment or product
under this section and any onsite inspections shall be submitted
in accordance with ch. SPS 302.
(4) UNGRADED OR USED MATERIALS. (a) Ungraded or used
building materials may be used or reused as long as the material
possesses the essential properties necessary to achieve the level
of performance required by the code for the intended use.
(b) The department or the municipality enforcing this code
may require tests in accordance with sub. (1) or (2).
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.16 Petition for variance. The department
may grant a variance to a rule only if the variance does not result
in lowering the level of health, safety, and welfare established or
intended by the rule. The department may consider other criteria
in determining whether a variance should be granted including
the effect of the variance on uniformity.
(1) APPLICATION FOR VARIANCE. Application for a petition
for variance shall be made on a form furnished by the depart-
ment. The applicant shall submit the petition for variance appli-
cation to the municipality exercising jurisdiction in order to re-
ceive the municipal recommendation. Where no municipality ex-
ercises jurisdiction, the application shall be submitted to the de-
partment. The following items shall be submitted when request-
ing a variance:
(a) A clear written statement of the specific provisions of this
code from which a variance is requested and the method of estab-
lishing equivalency to those provisions.
(b) A fee in accordance with s. SPS 302.52. The municipality
may require a fee for the processing of the application in addition
to the department[s fee.
Note: A copy of the petition for variance form, SBD-9890, is contained in ch.
SPS 325 Appendix A.
(2) MUNICIPAL RECOMMENDATION. The municipality ad-
ministering and enforcing this code shall submit all applications
for variance to the department, together with a municipal recom-
mendation within 10 business days after receipt of the applica-
tion. The recommendation of the municipality shall include the
following items:
(a) Inspections performed on the property.
(b) The issuance of correction orders on the property.
(c) An assessment of the overall impact of the variance on the
municipality.
Note: A copy of the municipal recommendation form, SBD-9890, is contained
in ch. SPS 325 Appendix A.
(3) DEPARTMENTAL ACTION. Where a municipality adminis-
ters and enforces the code, the department shall decide petitions
for variance and shall mail notification to the municipality and
the applicant within 5 business days after receipt of the applica-
tion and municipal recommendation. Where the department en-
forces the code, the department shall decide petitions for variance
within 15 business days after receipt of the application and fees.
(4) APPEALS. A person or municipality may appeal the deter-
mination of the department in the manner set out in s. 101.02 (6)
(e) to (i) and (8), Stats.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.17 Municipal variance from the code. Any
municipality exercising or intending to exercise jurisdiction un-
der this code may apply to the department for a variance permit-
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 131 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
7 SAFETY AND PROFESSIONAL SERVICES SPS 327.19
ting the municipality to adopt an ordinance not in conformance
with this code. The department shall review and make a determi-
nation on a municipal request to adopt an ordinance not in confor-
mance with this code within 60 business days of receipt of the
request.
(1) APPLICATION FOR VARIANCE. The department may grant
an application only under the following circumstances:
(a) The municipality has demonstrated that the variance is
necessary to protect the health, safety, or welfare of individuals
within the municipality because of specific climate or soil condi-
tions generally existing within the municipality.
(b) The municipality has demonstrated that the granting of
the variance, when viewed both individually and in conjunction
with other variances requested by the municipality, does not im-
pair the statewide uniformity of this code.
(2) DEPARTMENTAL INQUIRY. Prior to making a determina-
tion, the department shall solicit within the municipality and con-
sider the statements of any interested persons as to whether or not
said application should be granted.
(3) APPEALS. Any municipality aggrieved by the denial of an
application may appeal the determination in accordance with the
procedure set out in s. 101.02 (6) (e) to (i) and (8), Stats. The de-
partment shall review and make a determination on an appeal of
denial of a municipal request to adopt an ordinance not in confor-
mance with this code within 60 business days of receipt of the
appeal.
(4) UNIFORMITY. This section shall be strictly construed in
accordance with the goal of promoting statewide uniformity.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.18 Appeals of orders, determinations,
and for extension of time. (1) APPEALS OF ORDERS AND DE-
TERMINATIONS BY A MUNICIPALITY EXERCISING JURISDICTION.
Appeals of order or determination of a municipality exercising
jurisdiction under this code, including denials of application for
permits, shall be made in accordance with the procedure set out
in ch. 68, Stats., prior to making an appeal to the department, ex-
cept as provided in sub. (2).
(2) APPEALS OF FINAL DETERMINATIONS BY A MUNICIPALITY
EXERCISING JURISDICTION. Appeals of final determinations by
municipalities shall be made to the department after the proce-
dures prescribed in ch. 68, Stats., have been exhausted. All ap-
peals to the department shall be in writing stating the reason for
the appeal. All appeals shall be filed with the department within
10 business days of the date the final determination is rendered
under ch. 68, Stats. The department shall render a written deci-
sion on all appeals within 60 business days of receipt of all calcu-
lations and documents necessary to complete the review.
Note: Chapter 68, Stats., provides that municipalities may adopt alternate admin-
istrative appeal procedures that provide the same due process rights as ch. 68, Stats.
Municipalities having adopted such alternate procedures may follow those alternate
procedures.
(3) APPEALS OF ORDERS AND DETERMINATIONS BY THE DE-
PARTMENT. Appeals of orders or determinations of the depart-
ment made pursuant to the provisions of this code, including de-
nials of application for permits, shall be in accordance with the
procedure set out in s. 101.02 (6) (e) to (i) and (8), Stats. The de-
partment shall review and make a determination on an appeal of
an order or determination within 60 business days of receipt of all
calculations and documents necessary to complete the review.
(4) EXTENSIONS OF TIME. (a) The time for correction of
cited orders as set out in s. SPS 327.11 shall automatically be ex-
tended in the event that an appeal of the orders is filed. The ex-
tension of time shall extend to the termination of the appeal pro-
cedure and for additional time as the department or municipality
administering and enforcing this code may allow.
(b) The department or municipality administering and enforc-
ing this code may grant additional reasonable time in which to
comply with a violation order.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.19 Adoption of standards. (1) CONSENT.
Pursuant to s. 227.21 (2) , Stats., the attorney general has con-
sented to the incorporation by reference of the standards listed in
Tables 327.19-1 to 327.19-7.
(2) ADOPTION OF STANDARDS. The standards referenced in
Tables 327.19-1 to 327.19-7 are incorporated by reference into
this chapter.
Note: Copies of the adopted standards are on file in the offices of the department
and the legislative reference bureau. Copies of the standards may be purchased, or
are available for free, through the respective organizations or other information
listed in Tables 327.19-1 to 327.19-7.
(3) ALTERNATE STANDARDS. (a) Alternate standards that are
equivalent to or more stringent than the standards incorporated by
reference in this chapter may be used in lieu of incorporated stan-
dards when approved by the department or if written approval is
issued by the department in accordance with par. (b).
(b) 1. a. Upon receipt of a fee and a written request, the de-
partment may issue an approval for the use of the alternate
standard.
b. The department shall review and make a determination on
an application for approval within 40 business days of receipt of
all forms, fees, and documents required to complete the review.
2. Determination of approval shall be based on an analysis of
the alternate standard and the incorporated standard, prepared by
a qualified independent third party or the organization that pub-
lished the incorporated standard.
3. The department may include specific conditions in issuing
an approval, including an expiration date for the approval. Viola-
tions of the conditions under which an approval is issued shall
constitute a violation of this code.
4. If the department determines that the alternate standard is
not equivalent to or more stringent than the standards incorpo-
rated by reference, the request for approval shall be denied in
writing.
5. The department may revoke an approval for any false
statements or misrepresentations of facts on which the approval
was based. The department may re-examine an approved alter-
nate standard and issue a revised approval at any time.
6. Fees for review of standards under this paragraph shall be
submitted in accordance with ch. SPS 302.
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 132 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.19 WISCONSIN ADMINISTRATIVE CODE 8
Table 327.19-1
ASHRAE American Society of Heating, Refrigerating, and Air-
conditioning Engineers, Inc. 1791 Tullie Circle, N.E. At-
lanta, GA 30329 www.ashrae.org
Standard Reference Number Title
1. 2013 Fundamentals ASHRAE Handbook — Fundamentals
2. 2011 HV AC Applications ASHRAE Handbook — HV AC Applications
3. 2012 HV AC Systems & Equipment ASHRAE Handbook — HV AC Systems & Equipment
Table 327.19-2
AWC American Wood Council 222 Catoctin Circle SE Suite 201
Leesburg, V A 20175 www.americanwoodcouncil.org
Standard Reference Number Title
1. ANSI/AWC NDS — 2015 National Design Specification For Wood Construction
2. ANSI/AWC PWF — 2007 Permanent Wood Foundation Design Specification
Table 327.19-3
ICC The International Code Council 500 New Jersey Avenue,
NW, 6th Floor Washington, D.C. 20001 www.iccsafe.org
Standard Reference Number Title
ICC 400-2012 Standard on the Design and Construction of Log Structures
Table 327.19-4
NAIMA North American Insulation Manufacturers Association 11
Canal Canter Plaza, Suite 103 Alexandria, V A 22314
www.naima.org
Standard Reference Number Title
1. 3rd Edition, 2002 Fibrous Glass Residential Duct Construction Standards
Table 327.19-5
NFPA National Fire Protection Association 1 Batterymarch Park
Quincy, MA 02269 www.nfpa.org
Standard Reference Number Title
1. NFPA 54/ANSI Z223.1 2015 National Fuel Gas Code
Table 327.19-6
SMACNA Sheet Metal and Air Conditioning Contractors[ National
Association 4201 Lafayette Center Drive Chantilly, V A
20151-1219 www.smacna.org
Standard Reference Number Title
1. Seventh Edition, 1998 Residential Comfort System Installation Standards Manual
2. Seventh Edition, 2003 Fibrous Glass Duct Construction Standards
3. Third Edition, 2005 HV AC Duct Construction Standards — Metal and Flexible
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 133 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
9 SAFETY AND PROFESSIONAL SERVICES SPS 327.20
Table 327.19-7
TPI Truss Plate Institute, Inc. 218 North Lee Street, Suite 312
Alexandria, V A 22314 www.tpinst.org
Standard Reference Number Title
ANSI/TPI 1-2007 National Design Standard for Metal Plate Connected Wood
Truss Construction
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018 No. 747, eff. 4-1-18.
Subchapter II — Construction Standards
SPS 327.20 Loads and materials. Every camping unit
shall be designed and constructed in accordance with the require-
ments of this section.
(1) DESIGN LOAD. Every camping unit shall be designed and
constructed to support the actual dead load and live loads acting
upon it without exceeding the allowable stresses of the material.
The construction of camping units shall result in a system that
provides a complete load path capable of transferring all loads
from point of origin through the load-resisting elements to the
ground.
(a) Dead loads. Every camping unit shall be designed and
constructed to support the actual weight of all components and
materials. Earth-sheltered camping units shall be designed and
constructed to support the actual weight of all soil loads.
(b) Live loads. Floors and ceilings shall be designed and con-
structed to support the minimum live loads listed in Table
327.20-1. The design load shall be applied uniformly over the
component area.
Table 327.20-1
Component Live Load (pounds per sq. ft.)
Floors 40
Exterior balconies and porches 40
Ceilings (with storage) 20
Ceilings (without storage) 5
(2) METHODS OF DESIGN. All camping units shall be de-
signed by the method of structural analysis or the method of ac-
cepted practice specified in each part of this code.
Note: See ch. NR 116, rules of the department of natural resources, for special
requirements relating to buildings located in flood plain zones. Information regard-
ing the elevation of the regional flood may be obtained from the local zoning
official.
(3) STRUCTURAL STANDARDS. (a) General. Design, con-
struction, installation, practice and structural analysis shall con-
form to the following nationally recognized standards.
(b) Wood. 1. Structural lumber, glue-laminated timber, tim-
ber pilings, and fastenings shall be designed in accordance with
the XNational Design Specification for Wood ConstructionY and
the XDesign Values for Wood Construction,Y a supplement to the
National Design Specification for Wood Construction, except the
provisions of section 4.1.7 shall also apply to reused lumber.
Reused lumber shall be considered to have a duration of load fac-
tor of 0.90.
2. Span tables for joists and rafters approved by the depart-
ment may be used in lieu of designing by structural analysis.
3. Sawn lumber that is not graded in accordance with the
standards under subd. 1., shall use the NDS published allowable
design stresses for the lumber species using grade number 3 when
used for studs, stringers, rafters or joists and may use grade num-
ber 1 when used for beams, posts, or timbers.
(c) Whole logs. Camping units constructed of whole logs
shall conform to ICC 400, Standard on the Design and Construc-
tion of Log Structures.
Note: This standard requires the minimum log diameter to be 8 inches.
(d) Fasteners. 1. All building components shall be fastened
to withstand the dead load and live load.
2. Fasteners shall comply with the schedule listed in Table
327.20-2, except other fastening methods may be allowed if engi-
neered under s. SPS 327.20 (3).
Table 327.20-2
MINIMUM FASTENER SCHEDULE TABLE
Other interior and exterior panel products and finishes installed per manufacturer requirements.
For engineered connectors, use manufacturer[s specified fasteners.
Description of Building Materials/Connection Number and Type of Fastener 1 2 3
Floor Framing
Joist to joist, face nailed over support 3-8d
Joist to sill or girder, toe nail 3-8d
Band or rim joist to joist, end nail 3-16d
Band or rim joist to sill or top plate 2-16d at 16 o.c.
Bridging to joist, toe nail each end 2-8d
Built-up girder and beams, top loaded 10d at 32 Y o.c. at top and bottom
and staggered and two at ends and at each splice
Built-up girder and beams, side-loaded 16d at 16 Y o.c. at top and bottom and staggered
and two at ends and at each splice
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 134 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.20 WISCONSIN ADMINISTRATIVE CODE 10
Ledger strip to beam, face nail 3-16d each joist
Joist on ledger to beam, toe nail 3-8d
Wall Framing
Sole plate to joist or blocking, face nail 2-16d at 16 Y o.c.
Top or sole plate to stud, end nail 2-16d
Stud to sole plate, toe nail 3-8d or 2 ]16d
Doubled studs, face nail 10d at 24 Y o.c.
Doubled top plates, face nail 10d at 24 Y o.c.
Doubled top plates, minimum 24Y offset of end joints, face nail 8 ]16d
in lapped area
Top plates, laps and intersections, face nail 2 ]10d
Continuous header, two pieces 16d at 16 Y o.c. along each edge
Continuous header to stud, toe nail 4-8d
1Y corner brace to each stud and plate, face nail 2-8d or 2 staples, 1 3/4 Y
Built-up corner studs 10d at 24 Y o.c.
Roof/Ceiling Framing
Ceiling joists to plate, toe nail 3-8d
Ceiling joist, laps over partitions, face nail 3 ]10d
Ceiling joist to parallel rafters, face nail 3-16d
Rafter to plate, toe nail (maximum 6 rafter span, engineered 2-16d
connector for longer)
Roof rafters to ridge, valley or hip rafters, toe nail 4-16d
Roof rafters to ridge, valley or hip rafters, face nail 3-16d
Collar ties to rafters, face nail 3-8d
Boards and planks
1Y x 6Y subfloor or less to each joist, face nail 2-8d or 2 staples, 1 3/4 Y
Wider than 1Y x 6Y subfloor toe to each joist, face nail 3-8d or 4 staples 1 3/4 Y
2Y subfloor to joist or girder, blind and face nail 2-16d
1Y x 6Y roof or wall sheathing to each bearing, face nail 2-8d or 2 staples, 1 3/4 Y
1Y x 8Y roof or wall sheathing to each bearing, face nail 2-8d or 3 staples, 1 3/4 Y
Wider than 1Y x 8Y roof sheathing to each bearing, face nail 3-8d or 4 staples, 1 3/4 Y
2Y planks 2-16d at each bearing
Panel Sheathing
Spacing of Fastener
Intermediate
Material Fastener Edges Supports
Engineered wood panel for
subfloor and roof sheathing
and wall corner wind bracing
to framing
5 /16Y to 1/2Y 6d common or deformed nail or staple, 1 1/2Y 6Y 12Y4
5 /8Y to 3/4Y 8d smooth or common, 6d deformed nail, or 6 Y 12Y4
staple, 14 ga. 1 3/4Y
7 /8Y to 1Y 8d common or deformed nail 6 Y 12Y
1 1 /8Y to 1 1/4Y 10d smooth or common or 8d deformed nail 6 Y 12Y
Combination
subfloor/ underlayment
to framing
3/4Y or less 6d deformed or 8d smooth or common nail 6 Y 12Y
7/8Y to 1Y 8d smooth, common or deformed nail 6 Y 12Y
1 1 /8Y to 1 1/4Y 10d smooth or common or 8d deformed nail 6 Y 12Y
Wood panel siding to framing
1/2Y or less 6d corrosion-resistant siding and casing nails 6 Y 12Y
5/8Y 8d corrosion-resistant siding and casing nails 6 Y 12Y
1/2Y structural cellulosic 1 1/2 Y galvanized roofing nail; 8d common nail; 3 Y 6Y
fiberboard sheathing staple 16 ga., 1 1/2 Y long
25/32Y structural cellulosic 1 3/4 Y galvanized roofing nail; 8d common nail; 3 Y 6Y
fiberboard sheathing staple 16 ga., 1 3/4 Y long
1/2Y gypsum sheathing5 1 1/2 Y galvanized roofing nail; 6d common nail; 4 Y 8Y
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 135 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
11 SAFETY AND PROFESSIONAL SERVICES SPS 327.24
staple galvanized 1 1/2Y long; 1 1/4Y screws, Type
W or S
5/8Y gypsum sheathing5 1 3/4 Y galvanized roofing nail; 8d common nail; 7 Y 7Y
staple galvanized 1 5/8Y long; 1 5/8Y screws, Type
W or S
1 All nails are smooth-common, box or deformed shank except where otherwise stated.
2 Nail is a general description and may be T-head, modified round head or round head.
3 Staples are 16-gauge wire, unless otherwise noted, and have a minimum 7 /16Y o.d. crown width.
4 Staples shall be spaced at not more than 10Y o.c. at intermediate supports for floors.
5 Apply vertically 4Y x 8Y or 4Y x 9Y panels.
(4) ALTERNATE MATERIALS AND STANDARDS. No part of
this code is intended to prohibit or discourage use of alternate,
equivalent materials or standards or the construction of innova-
tive or nonconventional camping units.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.21 Exits. Exits, doors, and hallways shall be
constructed as specified in this section.
(1) EXITS FROM THE FIRST FLOOR. (a) A first floor level shall
have at least one exit door that discharges to grade. This exit may
include interior or exterior stairs.
(b) A first floor level shall have at least one egress window
complying with sub. (3) on that floor level.
(c) If a camping unit has more than one room on the first
floor, the exit door and egress window shall be located in differ-
ent rooms.
(d) If there are bedrooms on the first floor, each must have an
egress window that complies with sub. (3).
(2) EXITS FROM LOFTS. At least one stairway or ladder exit
shall be provided to the floor below for a loft.
(3) WINDOWS USED FOR EXITING. Windows which are in-
stalled for exit purposes shall comply with the requirements of
this subsection.
(a) The window shall be openable from the inside without the
use of tools or the removal of a sash. If equipped with a storm or
screen, it shall be openable from the inside.
(b) 1. The nominal size of the net clear window opening shall
be at least 20 inches by 24 inches irrespective of height or width.
Nominal dimensions shall be determined by rounding up frac-
tions of inches if they are 1/2-inch or greater or rounding down
fractions of inches if they are less than 1/2-inch.
2. No portion of the window, including stops, stools, meeting
rails, and operator arms, shall infringe on the required opening.
(c) The area and dimension requirements of par. (b) may be
infringed on by a storm window.
(d) For any window used for exiting, the lowest point of clear
opening shall be no more than 60 inches above the floor.
(4) DOORS USED FOR EXITING. (a) A door used for exiting
from a camping unit shall be a swing-type door at least 80 inches
high by 32 inches wide.
(b) All exit doors shall be openable from the interior without
the use of a key.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.22 Stairways and elevated areas. (1)
HANDRAILS. (a) A flight of stairs with more than 3 risers shall
be provided with at least one handrail for the full length of the
flight.
(b) Handrails shall be designed and constructed to withstand
a 200 pound load applied in any direction.
(c) Exterior handrails shall be constructed of metal, decay re-
sistant or pressure-treated wood, or shall be protected from the
weather.
(2) GUARDS. (a) Except as provided in par. (b),all openings
between floors, and open sides of landings, platforms, balconies,
lofts, or porches that are more than 16 inches above grade or a
floor shall be protected with guards.
(b) For exterior applications, open sides of decks, landings,
porches, or similar structures that are more than 24 inches above
grade shall be protected with guards. The 24 inch vertical mea-
surement shall be taken from the lowest point within 3 feet hori-
zontally from the edge of the deck, landing, porch, or similar
structure.
(c) Guards shall be constructed to prevent the through-pas-
sage of a sphere with a diameter of 4 3/8 inches, when applying a
force of 4 pounds.
(d) This subsection does not apply to window wells, egress
wells, and retaining walls.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.23 Ladders. Ladders which are used as part of
a required exit shall be designed to withstand loads of at least 200
pounds.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.24 Ceiling height. All habitable rooms,
kitchens, hallways, bathrooms, and corridors shall have a ceiling
height of at least 7 feet, except as follows:
(1) (a) Rooms may have ceiling heights of less than 7 feet
provided at least 50% of the room[s floor area has a ceiling height
of at least 7 feet. Any area with a ceiling height of less than 5 feet
may be ignored in this calculation.
(b) The 50% limit in par. (a) does not apply to subs. (3) to (7).
(2) Beams and girders or other projections may project to no
more than 8 inches below the required ceiling height.
(3) The ceiling height extending back from the front edge of a
water closet may slope to below 7 feet, but may not go below 5
feet until beyond the back of the water closet.
(4) The ceiling height extending back from the front edge of a
lavatory may be less than 7 feet, but may not go below 5 feet until
beyond the back of the lavatory.
(5) A ceiling height of less than 7 feet may be provided be-
tween the rear rim of a bathtub and a wall of the room abutting
that rim, or between the side rim and a room wall abutting that
rim.
(6) A ceiling height of less than 7 feet may be provided be-
tween the rear wall of a shower stall and a wall of the room abut-
ting that rear wall, or between the side wall of a shower and a
room wall abutting that side wall.
(7) A ceiling height of less than 7 feet may be provided in a
loft used as a habitable room.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 136 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.25 WISCONSIN ADMINISTRATIVE CODE 12
SPS 327.25 Fireblocking. (1) FIREBLOCKING LOCA-
TIONS. Fireblocking shall be provided in all of the following
locations:
(a) In concealed spaces of walls and partitions, including
furred spaces, at the ceiling and floor levels.
(b) At all interconnections between concealed vertical and
horizontal spaces including the attachment between a carport and
a camping unit.
(c) In concealed spaces between stair stringers at the top and
bottom of the run and at any intervening floor level.
(d) At all openings around wires, cables, vents, pipes, ducts,
chimneys, and fireplaces at ceiling and floor level.
(2) FIREBLOCKING MATERIALS. Fireblocking shall consist of
one of the following:
(a) 2-inch nominal lumber.
(b) Two layers of one-inch nominal lumber.
(c) One thickness of 3/4-inch nominal plywood or wood
structural panel with any joints backed with the same material.
(d) One thickness of 1/2-inch gypsum wallboard, face nailed
or face screwed to solid wood, with any joints backed with the
same material.
(e) Fiberglass or mineral wool batt insulation may be used if
both of the following conditions are met:
1. The least dimension of the opening may not exceed 4
inches.
2. The batt shall be installed to fill the entire thickness of the
opening or stud cavity.
(f) For wires, cables, pipes, and vents only, non-shrinking
caulk, putty mortar, or similar material may be used provided no
dimension of the opening exceeds 1/2 inch around the penetrating
object.
(g) For chimneys, fireplaces, and metal vents, fireblocking
shall be metal, cement board, or other noncombustible material.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.26 Smoke detectors. (1) A listed and labeled
battery-operated smoke alarm shall be installed in all of the fol-
lowing locations:
(a) If a camping unit has a loft, an alarm shall be installed in-
side the loft. An alarm is not required to be installed outside of
the loft.
(b) On a floor level that contains one or more sleeping rooms,
an alarm shall be installed inside each sleeping room and an
alarm shall be installed outside of the sleeping rooms.
(c) An alarm shall be installed on a floor level that does not
contain a sleeping room.
Note: Section 101.645 (3), Stats., requires the owner of a dwelling to install a
functional smoke detector in the basement of the dwelling and on each floor level
except the attic or storage area of each dwelling unit. The occupant of such a
dwelling unit shall maintain any smoke detector in that unit, except that if any occu-
pant who is not the owner, or any state, county, city, village or town officer, agent or
employee charged under statute or municipal ordinance with powers or duties in-
volving inspection of real or personal property, gives written notice to the owner that
the smoke detector is not functional the owner shall provide, within 5 days after re-
ceipt of that notice, any maintenance necessary to make that smoke detector
functional.
(2) Smoke alarms and detectors shall be installed and main-
tained in accordance with the manufacturer [s specifications. In-
terconnection of smoke alarms and detectors is not required.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.27 Carbon monoxide alarms. (1) GEN-
ERAL. A listed and labeled carbon monoxide alarm shall be in-
stalled within 10 feet of a fireplace or fuel-burning appliance.
(2) ELECTRICAL SERVICE. If electrical service for a camping
unit is provided by a public utility, a carbon monoxide alarm re-
quired under sub. (1) shall be continuously powered by the camp-
ing unit electrical service and shall have a backup battery power
supply.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.28 Protection against decay and termites.
(1) Wood used in any of the applications under this section shall
meet all of the following requirements:
(a) The wood shall be labeled and pressure treated with
preservative in accordance with an AWPA standard or shall be
naturally durable and decay-resistant or shall be engineered to be
decay resistant.
(b) The wood shall be pressure treated with preservative or
shall be naturally termite-resistant unless additional steps are
taken to make the wood termite-resistant.
(2) Wood used in the following locations shall be as required
under sub. (1):
(a) Resting directly upon or embedded in earth.
(b) Floor joists or sleepers that meet all of the following
conditions:
1. The joists or sleepers are protected from the weather.
2. The joists or sleepers are within 18 inches above a lower
floor surface, deck or soil.
(c) Floor joists exterior to the camping unit that are within 18
inches above exterior grade, unless protected with a moisture
barrier.
Note: Acceptable moisture barriers for this application include 3/4 -inch exterior
preservative-treated plywood, or ice dam protection material listed as meeting the
requirements of ASTM D 1970 or vapor retarder material, provided they are pro-
tected from physical and UV light damage.
(d) Girders that span directly over and within 12 inches of
earth.
(e) Sills and rim joists that rest on concrete or masonry and
are also below grade or within 8 inches above final exterior grade.
(f) 1. Siding and sheathing in contact with concrete, masonry,
or earth and within 6 inches above final exterior grade.
2. Siding and sheathing in contact with concrete or masonry
and within 2 inches above an impervious surface.
(g) Ends of wood structural members and their shims resting
on or supported in masonry or concrete walls and having clear-
ances of less than 1/2 inch on the top, sides, and ends.
(h) Bottom plates or sole plates of walls that rest on concrete
or masonry and that are below exterior grade or less than 8 inches
above final exterior grade.
(i) Columns in direct contact with concrete or masonry unless
supported by a structural pedestal or plinth block at least one inch
above the floor.
(j) Any structural part of an outdoor deck, including the
decking.
(k) Permanent wood foundations.
(3) Wood girders that rest directly on exterior concrete or ma-
sonry shall be protected by one of the following methods:
(a) The wood shall be pressure treated with preservative or
shall be a naturally durable and decay-resistant species.
(b) Material, such as pressure-treated plywood, flashing ma-
terial, steel shims, or water-resistant membrane material shall be
placed between the wood and the concrete or masonry.
(4) All pressure-treated wood and plywood shall be identified
by a quality mark or certificate of inspection of an approved in-
spection agency which maintains continued supervision, testing,
and inspection over the quality of the product.
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 137 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
13 SAFETY AND PROFESSIONAL SERVICES SPS 327.31
Note: Heartwood of redwood, cypress, black walnut, catalpa, chestnut, sage or-
ange, red mulberry, white oak, or cedar lumber are considered by the department to
be naturally decay-resistant. Heartwood of bald cypress, redwood, and eastern red
cedar are considered by the department to be naturally termite resistant.
(5) (a) Fasteners for pressure-preservative treated wood and
fire-retardant-treated wood shall meet one of the following
requirements:
1. The fastener is a steel bolt with a diameter of 1/2 inch or
greater.
2. The fastener is made of stainless steel.
3. The fastener is made of hot-dipped, zinc-galvanized steel
with the coating weight and thickness labeled as complying with
ASTM A 153.
4. The fastener is made of steel with a mechanically-de-
posited zinc coating labeled as complying with ASTM B 695,
Class 55 or greater.
5. The fastener has coating types and weights in accordance
with the fastener manufacturer [s recommendations. In the ab-
sence of the manufacturer[s recommendations subd. 1., 2., 3., or
4. shall apply.
Note: XZinc plated,Y Xzinc coated,Y Xchrome plated,Y etc., fasteners do not nec-
essarily comply with either of these standards.
(b) When a fastener is used with a hanger or other metal fix-
ture, the fastener shall be of the same material as the hanger or
metal fixture.
Note: When separate pieces are in close contact, zinc corrodes rapidly in the
presence of plain steel. Zinc corrodes much more rapidly in the presence of stainless
steel.
(c) For the purposes of this section, a fastener includes nails,
screws, and bolts with nuts and washers.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.29 Floor design. Floors shall support all dead
loads plus the minimum unit live loads as set forth in s. SPS
327.20. The live loads shall be applied to act vertically and uni-
formly to each square foot of horizontal floor area.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.30 Wood floors in contact with the
ground. Wood floors in contact with the ground shall be de-
signed and constructed in accordance with the wood-foundation
standards adopted in Table 327.19-2.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.31 Wood frame floors. Unless designed
through structural analysis, wood frame floors shall comply with
the following requirements:
(1) FLOOR JOISTS. (a) Floor joists shall comply with the
structural requirements and live load determination under s. SPS
327.20.
(b) Where the joists of a floor system are parallel to, and lo-
cated between bearing walls above and below, the joists shall be
doubled.
(2) FLOOR TRUSSES. Metal plate connected wood floor
trusses shall be designed in accordance with the Design Specifi-
cations for Metal Plate Connected Parallel Chord Wood Trusses
and the National Design Specification for Wood Construction.
Truss members shall not be cut, bored or notched.
(3) GIRDERS AND BEAMS. (a) Wood girders and beams shall
be fitted at the post or column. Adjoining ends shall be fastened
to each other to transfer horizontal loads across the joint. Beams
shall also be fastened to the posts with framing anchors, angle
clips, or equivalent.
(b) Where intermediate beams are used, they shall rest on top
of the girders; or shall be supported by ledgers or blocks fastened
to the sides of the girders; or they may be supported by approved
metal hangers into which the ends of the beams shall be fitted.
(c) Lateral restraint for all wood beams shall be provided at all
columns using a saddle or other approved connection where the
beam meets one of the following conditions:
1. The beam is not restrained at both ends.
2. The beam is more than 11 1/4 inches deep using actual
measurement.
Note: A saddle supports the beam on the bottom and allows for the through-con-
nection of fasteners into the side of the beam.
(4) BEARING AND END CONFIGURATION. (a) Sawn lumber.
1. ZJoists.[ Wood joists made of sawn lumber shall meet the fol-
lowing bearing requirements:
a. Wood joists supported on wood or metal shall have a bear-
ing surface of at least 1 1/2-inches measured from the end of the
joist.
b. The tail end of a floor joist may not extend past the edge of
a beam by more than the depth of the floor joist.
c. Wood floor joists with ends that intersect over a beam
shall have the ends overlap at least 3 inches and be securely fas-
tened together with at least two 12d common nails or the ends
shall be butt-jointed or face-jointed and fastened with ties, straps,
plates or solid blocking.
2. ZBeams and girders. [ Beams and girders made of sawn
lumber shall have a bearing surface on their supports of at least 3
inches parallel to the beam or girder and be at least as wide as the
beam or girder.
(b) Engineered wood products. Bearing surface for engi-
neered wood products shall be in accordance with the manufac-
turer[s instructions provided those instructions were developed
through structural analysis or product testing and are applicable
to the configuration.
(5) NOTCHING AND BORING. Notching and boring of beams
or girders is prohibited unless determined through structural
analysis.
(a) Notching of floor joists. 1. Notches located in the top or
bottom of floor joists shall not have a depth exceeding 1/6 the
depth of the joist, shall not have a length exceeding 1/3 the joist
depth nor be located in the middle 1/3 of the span of the joist.
2. Where floor joists are notched on the ends, the notch shall
not exceed 1/4 the depth of the joist. Notches over supports may
extend the full bearing width of the support.
(b) Boring of floor joists. 1. ZGeneral.[ A hole may not be
bored in a floor joist within 2 inches of a notch or another hole.
In no case shall the distance between adjacent holes be less than
the diameter of the larger hole.
2. ZHoles near the edge.[ Holes bored in the top or bottom 2
inches of a joist shall follow the limitations for notching under
par. (a).
3. ZOther holes. [ Holes bored in floor joists that are not
within 2 inches of the top or bottom of the joist shall have their
diameter limited to 1/3 the depth of the joist.
(c) Engineered wood products. Notching or boring of engi-
neered wood products shall be done in accordance with the man-
ufacturer[s instructions provided those instructions were devel-
oped through structural analysis or product testing.
(6) OVERHANG OF FLOORS. (a) General. Except as provided
in pars. (b) and (c), a floor joist overhang shall be cantilevered be-
yond the outer edge of the supporting wall below it by no more
than the actual depth of the joist or shall be designed through
structural analysis in accordance with s. SPS 327.20 (3).
(b) Joist overhangs parallel to the main floor framing system.
Joist overhangs that are extensions of, and parallel to, the main
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 138 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.31 WISCONSIN ADMINISTRATIVE CODE 14
floor framing system may extend beyond the depth of the joist
without structural analysis provided they meet all of the follow-
ing conditions:
1. The overhang is cantilevered no more than 2 feet beyond
the outer edge of the supporting wall below it.
2. a. The overhang supports a uniform load limited to the
weight of the bearing wall and the tributary roof area above it.
b. The tributary length of the roof area, excluding the eave
overhang, is no more than 2 feet greater than the actual length of
the joist directly below.
c. The eave overhang is no more than 2 feet.
Note: The tributary length is usually half the span of the joist or rafter.
3. The joist overhang does not support any concentrated
loads. For the purposes of this subsection, a framed opening in
the wall with a rough opening of 4 feet or less shall be considered
uniform loading.
4. a. The cantilevered joist is doubled at the supporting wall.
b. The doubled joist length extends inward beyond the inner
edge of the supporting wall by the same distance as the cantilever.
c. The added joist member is secured to the main joist.
(c) Joist overhangs perpendicular to the main floor framing
system. Joist overhangs that are perpendicular to the main floor
framing system, or lookout joists, may extend beyond the depth of
the joist without structural analysis provided they meet all of the
following conditions:
1. The joist overhang is cantilevered no more than 2 feet be-
yond the outer edge of the supporting wall below it.
2. a. A double floor joist is used to support the lookout joist.
b. The double floor joist is located a distance of at least 2
times the cantilever length inward from the outer edge of the sup-
porting wall below.
c. The lookout joists are fastened to the double joist with
metal hangers.
3. The joist overhang supports no more than either a non-
bearing wall or a wall that supports only a roof which spans no
more than the floor overhang cantilever length plus the eave
overhang.
(d) Other joist overhangs. All overhangs longer than the
depth of the supporting joist that do not meet all of the conditions
under par. (b) or (c) shall be designed through structural analysis.
(7) FLOOR OPENINGS. Trimmers and headers shall be dou-
bled when the span of the header exceeds 4 feet. Headers which
span more than 6 feet shall have the ends supported by joist hang-
ers or framing anchors, unless the ends are supported on a parti-
tion or beam. Joists more than 8 feet long that frame into headers
shall be supported on metal framing anchors or on ledger strips of
at least 2 inches by 2 inches nominal.
(8) FLOOR SHEATHING, BOARDS AND PLANKS. (a) Plywood
sheathing. Plywood sheathing used for floors shall be limited to
the allowable loads and spans shown in Table 327.31-A.
(b) Combination subfloor-underlayment. Combination sub-
floor-underlayment shall be installed in accordance with Table
327.31-B.
(c) Floor boards. Where wood boards are used for floor
sheathing, the boards shall comply with the minimum thick-
nesses shown in Table 327.31-C.
(d) Planks. Planks shall be tongue and groove or splined and
at least 2 inches, nominal, in thickness. Planks shall terminate
over beams unless the joints are end matched. The planks shall
be laid so that no continuous line of joints will occur except at
points of support. Planks shall be nailed to each beam.
(9) BRIDGING. (a) Sawn lumber. Bridging shall be provided
for sawn lumber framing at intervals not exceeding 8 feet where
the nominal depth to thickness ratio is greater than 4 to 1.
Note: This 4:1 ratio means bridging is required for wood-framed floors having
nominal 2X10 or deeper solid-sawn-lumber joists, to provide restraint against rota-
tion or lateral displacement.
(b) Engineered products. Bridging shall be provided for engi-
neered framing products in accordance with the manufacturer [s
recommendations.
(10) SILL PLATES. All of the following requirements apply to
a sawn-lumber sill plate with uniform loading that is partially ex-
tended beyond the load-bearing surface of a foundation wall in
order to put the exterior surface of an upper-lying wall flush with
or beyond the exterior surface of insulation that is placed on the
outside of the foundation wall:
(a) The center of any anchor bolt shall be set back from the
side edge of the sill plate by a distance of at least 4 times the di-
ameter of the bolt.
(b) The thickness of the concrete or mortar cover around any
anchor bolt shall comply with ACI 318 section 7.7.
Note: Under ACI 318 section 7.7, the minimum cover for a 5/8-inch-diameter or
smaller bolt is 1 1/2 inches.
(c) With wood floor joists that are parallel to the foundation
wall, the sill plate may not extend beyond the load-bearing sur-
face of the wall by more than one-half of the nominal thickness of
the joist that bears on the sill plate.
(d) As used throughout this subchapter and in the standards
that the subchapter incorporates by reference, the shorter side of
the cross-sectional area of a wood member is the thickness of the
member. The longer side of the cross-sectional area is the depth,
when the longer side is vertical; and it is the width when the
longer side is horizontal.
Note: Under sub. (6), wood floor joists that are perpendicular to the foundation
wall can extend beyond the foundation wall by a distance of up to the depth of the
joist.
Table 327.31-A
ALLOWABLE SPANS FOR PLYWOOD FLOOR SHEATHING CONTINUOUS OVER TWO OR
MORE SPANS AND FACE GRAIN PERPENDICULAR TO SUPPORTS1
Span Rating2 Plywood Thickness Maximum span3
32/16 15/32 Y, 1/2Y, 5/8Y 16Y5
40/20 19/32 Y, 5/8Y, 3/4Y, 7/8Y 20Y4,5
48/24 23/32 Y, 3/4Y, 7/8Y 24Y
1 These values apply to C-D, C-C, and Structural I and II grades only. Spans shall be limited to values shown because of possible effect of concentrated
loads.
2 Span Rating appears on all panels in the construction grades listed in footnote 1.
3 Plywood edges shall have approved tongue and groove joints or shall be supported with blocking, unless 1/4 inch minimum thickness underlayment or
1 1/2 inches of approved cellular or lightweight concrete is installed or finished floor is 25/32-inch wood strip. Allowable uniform load based on deflec-
tion of 1/360 of span is 165 pounds per square foot.
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 139 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
15 SAFETY AND PROFESSIONAL SERVICES SPS 327.33
4 For joists spaced 24 inches on center, plywood sheathing with Span Rating 40/20 or greater can be used for subfloors when supporting 1 1/2 inches
lightweight concrete.
5 May be 24 inches if 25/32-inch wood strip flooring is installed at right angles to joists.
Table 327.31-B
MINIMUM THICKNESS FOR PLYWOOD COMBINATION
SUBFLOOR-UNDERLAYMENT. PLYWOOD CONTINUOUS OVER TWO OR MORE
SPANS AND FACE GRAIN PERPENDICULAR TO SUPPORTS1,2
Maximum Support Spacing3
16Y o.c 20 Y o.c 24 Y o.c
Plywood Panel Panel Panel
Species Thickness Thickness Thickness
Plywood Grade Group (inches) (inches) (inches)
Sanded exterior type 1 1/2 5/8 3/4
2 & 3 5/8 3/4 7/8
4 3/4 7/8 1
Underlayment C-C All Groups APA Rated Sheathing and APA Rated
Plugged Sturd-I-Floor4 Sturd-I-Floor shall be installed consistent
with their rating.
1 Spans shall be limited to values shown, based on possible effect of concentrated loads.
2 Unsupported edges shall be tongue and groove or blocked except where 1/4 inch underlayment or 25/32-inch finish floor is used.
3 Underlayment, C-C Plugged, sanded exterior type: allowable uniform load based on deflection of L/360 span for spans 24 inches or less is 125 psf; and
for spans 48 inches, 65 psf.
4 The department will accept subfloor underlayment panels such as Sturd-I-Floor which meet the requirements of APA manufacturing specifications
for Sturd-I-Floor panels.
Table 327.31-C
MINIMUM THICKNESS OF FLOOR BOARDS
Minimum Net Thickness
Joist Spacing Perpendicular to Joist Diagonal to Joist
24Y 11/16Y 3/4Y
16Y 5/8Y 5/8Y
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018 No. 747, eff. 4-1-18; (6) (d) (title) created under s. 13.92 (4) (b) 1., Stats., Register March
2018 No. 747.
SPS 327.32 Decks. A deck attached to a camping unit or
any detached deck that serves an exit from a camping unit that
meets the following requirements is in compliance with this code:
(1) A deck shall be constructed to support the actual dead
load and a minimum live load of 40 pounds per square inch acting
on it without exceeding the allowable stresses of the material.
(2) A deck attached to a camping unit shall have a ledger at-
tachment that meets the requirement under sub. (1).
(3) Corrosion-resistant flashing shall be installed where a
deck attaches to the wall or floor assembly of a camping unit.
(4) The handrail and guard requirements of s. SPS 327.22.
(5) The decay protection requirements of s. SPS 327.28.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.33 Exterior covering. (1) GENERAL. The ex-
terior walls shall be covered with a permanent weather resistant
finish.
(2) DURING CONSTRUCTION. During construction, wall cav-
ity insulation may not be installed until a water-resistant covering
is in place over the wall cavity and windows, doors and a roof
with at least underlayment are installed.
Note: An example of acceptable water-resistant covering for a wall is foam
sheathing with permanently taped joints.
(3) FLASHING. (a) Corrosion-resistant flashing shall be in-
stalled in the exterior wall to prevent water from entering the wall
cavity or coming in contact with the structural framing
components.
(b) The flashing shall extend to the surface of the exterior
wall finish and prevent water from reentering the exterior wall.
(c) 1. Any joints between 2 pieces of flashing that form a ver-
tical joint shall be lapped a minimum of 6 inches and sealed.
2. Any joints between 2 pieces of flashing that form a hori-
zontal joint shall be lapped a minimum of 2 inches and sealed un-
less otherwise specified by the flashing manufacturer.
3. Sealants used for flashing shall be exterior grade and shall
be compatible with the materials being sealed.
(d) Flashing shall be provided at all of the following locations:
1. At the top of all exterior door and window openings, un-
less using self-flashing windows that provide at least one inch of
flashing around the opening, including the corners.
2. At the intersection of chimneys or other masonry con-
struction with frame walls.
3. Under and at the ends of masonry, wood, or metal copings
and sills.
4. Continuously above all projecting wood trim.
5. Where porches, decks, or stairs attach to a wall or floor as-
sembly of wood frame construction.
6. At wall and roof intersections.
7. At built-in gutters.
8. Along the bottom of door openings that are elevated
above-grade.
Note: Flashing placed along the bottom of a door opening that is elevated above-
grade can subsequently accommodate adding a deck outside the door.
(e) For a roof that intersects with an upper-lying head wall and
rake wall, such as where a dormer is provided, the vertical metal
flashing along the rake wall shall extend down the roof at least
one-half inch past the vertical flashing on the head wall. A head
wall as addressed in this paragraph intersects a sloping roof at a
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 140 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.33 WISCONSIN ADMINISTRATIVE CODE 16
horizontal line along the top of a roof segment. A rake wall inter-
sects a sloping roof along the side of a roof segment.
(f) For a roof eave that intersects with a sidewall, the end of
the roof flashing shall be installed so that it diverts water away
from the sidewall and onto the roof or into the gutter.
(4) WATER-RESISTIVE BARRIER REQUIREMENTS. (a) Gen-
eral. 1. Exterior walls of wood or metal frame construction shall
be provided with a water-resistive barrier from the highest point
to the bottom of the permanent weather-resistant covering.
Note: Acceptable water-resistive barrier materials include polymeric-based
house wraps and spray-applied water-resistive barriers installed per the manufac-
turer[s instructions, #15 or greater asphalt-saturated felts that comply with ASTM D
226 for type I felt and extruded foam sheathing with permanently taped joints. Duct
tape or similar materials will not result in a permanently taped joint.
2. Structural products with an integral water-resistive barrier
may be approved as a complete assembly.
(b) Material compatibility. The water-resistive barrier mate-
rial shall be compatible with the other materials in the wall with
which it will come into contact.
Note: Spray-applied water-resistive barriers may not be compatible with foam
plastic insulation.
(c) Performance requirements. 1. Polymer-based house
wraps shall meet all of the following requirements:
a. A water vapor permeability rating of 5 perms or higher
when tested in accordance with ASTM E96.
b. An acceptable water-resistance rating determined in accor-
dance with ASTM D779, AATCC 127 or CCMC 07102.
Note: Asphalt-saturated felt or Xtar paperY is not a polymeric-based house wrap.
Note: For more information on the water-resistance tests and their results, see the
International Code Council Evaluation Services Acceptance Criteria AC 38.
2. Spray-applied water-resistive barriers shall be approved
under the International Code Council Evaluation Services.
Note: For approval criteria, see ICC-ES acceptance criteria AC 212 or successor
document.
(d) Application. 1. Horizontal seams in sheet or strip mate-
rial shall be overlapped such that the upper layer extends over the
lower layer at least 2 inches.
2. Vertical seams in sheet or strip materials shall be over-
lapped at least 6 inches.
3. Any rips, tears or voids shall be patched in accordance
with subds. 1. and 2.
(e) Penetrations. 1. Penetrations caused by fasteners of the
water-resistive barrier or the weather-resistant exterior covering
do not require sealing.
2. Penetrations of 5 square inches or less with an annular
space of no more than 1/2 inch shall be sealed with caulk or sim-
ilar material.
3. Penetrations of greater than 5 square inches shall be
flashed in accordance with sub. (3).
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.34 Wood frame walls. Unless designed
through structural analysis, wood frame walls shall comply with
the following requirements:
(1) STUD CONFIGURATION. Studs in the exterior walls shall
be placed with the wide faces perpendicular to the plane of the
wall.
Note: See s. SPS 327.28 for requirements on treating wood for decay and termite
resistance.
(2) TOP PLATES. (a) General. Except as allowed under par.
(c), top plates shall be provided and configured as follows:
1. Studs at bearing walls shall be capped with double top
plates.
2. End joints in double top plates shall be offset at least 2
stud spaces.
3. Double top plates shall be overlapped at the corners and at
intersections of partitions.
4. The plate immediately above the stud may have a joint
only when directly over the stud.
(b) Notching and boring. 1. When piping or ductwork is
placed in an exterior wall or an interior load-bearing wall, such
that at least half of the top plate is removed, the plate shall be re-
inforced with a steel angle at least 2 inches by 2 inches by 20
gauge thick.
Note: 20 gauge is approximately 0.036 inch.
2. The steel angle shall span the gap and extend at least to the
midpoint of the adjacent stud spaces.
3. Other equivalent materials may be used in accordance
with s. SPS 327.20.
(c) Exceptions. 1. A single top plate may be used in place of
a double top plate provided a rafter is located directly over the
studs and the plate is securely tied at the end joints, corners and
intersecting walls. Joints may occur in single top plates only
when directly over a stud.
2. A continuous header, consisting of two 2-inch members
set on edge, may be used in lieu of a double plate if tied to the ad-
jacent wall.
(3) WALL OPENINGS. (a) Headers. Where doors or windows
occur, headers shall be used to carry the load across the opening.
(b) Header support. Headers in bearing walls shall be sup-
ported in accordance with the following:
1. Headers 3 feet or less in length shall be directly supported
on each end by one of the following:
a. The single common stud and a shoulder stud.
b. The single common stud with a framing anchor attached.
2. Headers greater than 3 feet but less than or equal to 6 feet
in length shall be directly supported on each end by the single
common stud and a shoulder stud.
3. Headers greater than 6 feet in length shall be directly sup-
ported on each end by the single common stud and 2 shoulder
studs.
(4) NOTCHING. Notching and boring of columns or posts is
prohibited unless designed through structural analysis. Studs
shall not be cut or bored more than 1/3 the depth of the stud, un-
less the stud is reinforced.
(5) PARTITIONS. Load-bearing partitions shall be placed over
beams, girders, or other load-bearing partitions. Load-bearing
partitions running at right angles to the joists shall not be offset
from the main girder or walls more than the depth of the joist un-
less the joists are designed to carry the load.
(6) POSTS AND COLUMNS. (a) General. 1. Posts and col-
umns shall be installed to resist imposed loads.
2. Posts and columns shall bear directly over the middle 1/3
of a footing.
3. Posts and columns shall be restrained at the top and bot-
tom to resist displacement.
4. All columns shall be positively attached to the beams they
support using clips, straps or saddles.
5. Posts and columns that use a height adjustment mecha-
nism shall have the mechanism imbedded in concrete or perma-
nently disabled after installation.
(b) Bearing surface. Posts and columns shall have a steel
bearing plate affixed to one or both ends to distribute any applied
loads and to prevent fiber crushing of any structural member be-
ing supported.
(c) Steel posts or columns. Steel posts or columns shall be
sized according to one of the following methods:
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 141 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
17 SAFETY AND PROFESSIONAL SERVICES SPS 327.35
1. Manufactured columns shall follow the manufacturer [s
testing and listing.
2. Columns made of steel stock, not meeting the require-
ments of subd. 1., shall follow a nationally accepted design spec-
ification or the size shall be determined through structural analy-
sis or load testing.
(d) Wood posts or columns. Wood posts or columns shall be
sized according to Table 327.34 or the size shall be determined
through structural analysis or load testing.
(7) FOUNDATION CRIPPLE WALLS. (a) Foundation cripple
walls shall be framed with studs at least as large as the studs
above.
(b) When more than 4 feet in height, cripple walls shall be
framed with studs needed for an additional floor level.
(c) Cripple walls shall be sheathed on at least one side for its
entire length with a wood structural panel that is fastened to both
the top and bottom plates or the cripple walls shall be constructed
of solid blocking.
(d) Cripple walls shall be fully supported by a continuous
foundation.
Table 327.34
WOOD COLUMNS
Wood Nominal Size Cross Section Area Height (feet) Allowable Load (pounds)
8 4,900
4Y x 4Y 12 1/4Y 10 3,100
12 2,150
8 7,700
4Y x 6Y 19 1/4Y 10 4,900
12 3,400
8 30,000
6Y x 6Y 30 1/4Y 10 18,900
12 13,300
Note: This Table is based on a modulus of elasticity or E of 1,000,000 psi and a fiber bending strength or Fb of 1,000 psi.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018 No. 747, eff. 4-1-18.
SPS 327.35 Roof design and framing. (1) ROOF
RAFTERS. (a) General. 1. Rafters shall be notched to fit the ex-
terior wall plate and fastened to the wall.
2. Collar ties shall be installed on the upper third of every
third pair of abutting roof rafters or every 48 inches, whichever is
less.
(b) Ridge boards. 1. Where rafters meet to form a ridge, the
rafters shall be attached to a ridge board.
2. The ridge board shall have a depth at least equal to the
length of the cut end of the rafter abutting it.
3. Where all rafters are placed directly opposite each other or
are offset at the ridge board by less than the thickness of the
rafter, the ridge board shall have a nominal thickness of at least 1
inch.
4. Where one or more rafters are offset at the ridge board by
more than the thickness of the rafter, the ridge board shall have a
nominal thickness of at least 2 inches.
(c) Ridge beams. Rafters shall be attached to ridge beams us-
ing engineered clips, straps, or hangers or the connection shall be
designed through structural analysis.
(d) Bearing. The required bearing for wood rafters shall be in
accordance with the NDS adopted in Table 327.19-2, except in no
case shall the bearing be less than 1 1/2 inches on wood or metal
or less than 3 inches on masonry or concrete.
(e) Ladders. 1. In this paragraph, XladderY means a perpen-
dicular projection extending beyond the face of the wall below.
2. Overhangs at gable end walls of more than 12 inches shall
be provided with ladders which extend into the structure a dis-
tance no less than the length of the overhang.
3. The ladders shall be fastened at the wall.
4. The interior end of each ladder shall be attached to a rafter
or truss with a hanger.
(2) CEILING JOISTS. (a) Ceiling joists shall be nailed to exte-
rior walls and to the ends of rafters.
(b) Ends of ceiling joists shall be lapped at least 3 inches and
be fastened either with 3-16d nails or in accordance with the
floor joist requirements under s. SPS 327.31 (4) (a) 1. c.
(c) Where ceiling joists are placed at right angles to the
rafters, the lookout joist or ties shall be fastened to the parallel
ceiling joists or rafters using engineered clips, straps or hangers
or the connection shall be designed through structural analysis.
(3) VALLEY AND HIP RAFTERS. (a) Valley rafters. 1. Where
no bearing is provided under valley rafters at the intersection of 2
roof areas, the valley rafters shall be doubled in thickness and
shall be at least 2 inches deeper than the required common rafter
to permit full bearing at the beveled end.
2. Where ridges are provided at different elevations, vertical
support shall be provided for the interior end of the lower ridge
board or ridge beam.
(b) Hip rafters. Where no bearing is provided under hip
rafters, the hip rafters shall be of the same thickness as common
rafters and shall be at least 2 inches deeper than required to per-
mit full contact with the jack rafter.
(4) ROOF TRUSSES. (a) Metal plate connected wood roof
trusses shall be designed in accordance with TPI 1 and the NDS
adopted under s. SPS 327.19.
(b) Truss members shall not be cut, bored or notched, except
as allowed under sub. (5) (d).
(c) If connection is provided to stabilize a non-load bearing
wall, a slotted expansion joint or clip shall be used.
(5) NOTCHING AND BORING. (a) General. 1. Notching and
boring of beams or girders is prohibited unless determined
through structural analysis.
2. Notching and boring of ceiling joists and rafters shall
comply with pars. (b) and (c).
(b) Notching. 1. Notches located in the top or bottom of ceil-
ing joists and rafters are prohibited from all of the following:
a. Having a depth exceeding 1/6 the depth of the member.
b. Having a length exceeding 1/3 the depth of the member.
c. Being located in the middle 1/3 of the span of the member.
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 142 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
SPS 327.35 WISCONSIN ADMINISTRATIVE CODE 18
2. Where ceiling joists or rafters are notched at the ends, the
notch may not exceed 1/4 the depth of the member.
3. Bird mouth cuts may not exceed 1/3 the depth of the rafter
unless the seat cut bears fully on the wall plate.
(c) Boring. 1. Holes bored within 2 inches of the top or bot-
tom of ceiling joists or rafters may not be located in the middle
1/3 of the span of the member.
2. The diameter of a hole may not exceed 1/3 the depth of the
member.
3. A hole may not be bored within 2 inches of a notch or an-
other hole.
4. The distance between adjacent holes may not be less than
the diameter of the larger hole.
(d) Engineered wood products. Notching or boring of engi-
neered wood products shall be done in accordance with the man-
ufacturer[s instructions provided those instructions were devel-
oped through structural analysis or product testing.
(6) ROOF SHEATHING, BOARDS AND PLANKING. (a) Struc-
tural sheathing. The allowable loads and spans for structural
sheathing shall be in accordance with the grade stamp on the
panel.
(b) Roof boards. 1. Where the rafter spacing is 24 inches on
center or less, roof boards may be used that have a minimum
thickness of 5/8-inch for solid sheathing and 3/4-inch for spaced
sheathing.
2. Where the rafter spacing is greater than 24 inches on cen-
ter, roof boards shall be tongue and groove, at least 1 1/2 inches
thick.
(c) Roof planks. 1. Roof planks shall be tongue and groove or
splined and at least 2 inches, nominal, in thickness.
2. Planks shall terminate over beams unless the joints are end
matched.
3. The planks shall be laid so that no continuous line of
joints will occur except at points of support.
4. Planks shall be nailed or fastened to each beam.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.36 Weather protection for roofs. (1) GEN-
ERAL. (a) All roofs shall be designed and constructed to assure
drainage of water.
(b) All fasteners shall be corrosion resistant.
(2) UNDERLAYMENT FOR SHINGLES. Underlayment consist-
ing of number 15 asphalt-impregnated felt paper or equivalent or
other type I material that shows no water transmission when
tested in accordance with ASTM D 226 or ASTM D 4869 shall
be provided under shingles. Underlayment materials meeting the
requirements of ASTM D 1970 meet the performance require-
ments of this subsection.
(3) ASPHALT SHINGLES. (a) General. 1. Shingles that have
a self-sealing adhesive strip shall include a sealant which has an
average bond strength of at least 1 1/2 pounds per 3 3/4 inches of
shingle width, at 32 degrees Fahrenheit. The department will ac-
cept results of testing conducted in accordance with an approved
test method for verifying compliance with the sealant uplift resis-
tance required in this paragraph. Information on the applicable
test method may be obtained from the department.
2. Each shingle package shall be labeled by the manufacturer
to indicate conformance to the applicable ASTM standard for
each type of shingle or the exception in par. (b).
3. Shingles shall be installed in accordance with the manu-
facturer[s recommendations.
4. Shingles shall have at least 4 fasteners per strip shingle or
2 fasteners per interlocking shingle, unless the manufacturer has
other specifications.
5. Shingle head lap shall be at least 2 inches, unless the man-
ufacturer has other specifications.
6. All fasteners for shingles shall be corrosion-resistant.
Note: See s. SPS 327.08 (54) for definitions of shingle terms.
Note: Section SPS 327.04 (2) requires compliance with all parts of this code, in-
cluding these roofing provisions, for an alteration to any camping unit that is regu-
lated under this code.
(b) Fiberglass shingles. Fiberglass asphalt shingles shall con-
form to ASTM D 3462 except that laminated shingles shall have
a tear strength of at least 1450 grams in each ply.
(4) OTHER ROOF COVERINGS. All roof coverings not other-
wise addressed in this section shall be installed in accordance
with the manufacturer[s instructions or a national standard recog-
nized by the department.
(5) REROOFING. New roof coverings may not be installed
over existing roof coverings where any of the following condi-
tions exist:
(a) The existing roof or roof covering is water-soaked or has
deteriorated such that it is inadequate as a base for additional
roofing.
(b) The existing roof is wood shake, slate, clay, cement, or as-
bestos-cement tile.
(c) The existing roof has 2 or more applications of any type of
permanent roof covering.
(6) FLASHING. (a) General. Flashing shall be installed at the
junction of chimneys and roofs, in all valleys, and around all roof
openings.
(b) Flashing of open valleys. 1. Open valleys shall be flashed
with at least No. 28 gauge corrosion-resistant sheet metal, 16
inches wide, or a layer of at least 50-pound roll roofing, 16 inches
wide, placed over a layer of number 15 roofing underlayment.
2. Flashing sections shall be overlapped by at least 4 inches.
(c) Flashing of closed valleys. Where shingles are laced or
woven over the valley, the valley shall be flashed with one of the
following:
1. At least one layer of 50-pound roofing, at least 20 inches
wide, over a layer of number 15 roofing underlayment.
2. A product labeled as meeting the requirements of ASTM
D1970.
(d) Chimney flashing. 1. Chimneys shall be flashed and
counter-flashed to a height of at least 6 inches.
2. Chimney crickets or saddles shall be installed where the
upper side of a chimney is more than 30 inches wide on a sloping
roof.
3. The intersection of the cricket and the chimney shall be
flashed and counter-flashed to a height of at least 6 inches.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
Subchapter III — Heating, Ventilating, and Air
Conditioning
SPS 327.37 Scope. The provisions of this subchapter
shall apply to the design, installation, and construction of all heat-
ing, ventilating, and air conditioning systems in camping units
covered by this code.
History: EmR1703: emerg. cr., eff. 2-6-17; CR 17-017: cr. Register March 2018
No. 747, eff. 4-1-18.
SPS 327.38 Design. Where a heating system is provided
in a camping unit, the heating system shall be designed in accor-
dance with this section. Where a cooling system is provided in a
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date
the chapter was last published.
Register November 2024 No. 827
Page 143 of 271
Published under s. 35.93, Wis. Stats., by the Legislative Reference Bureau.
19 SAFETY AND PROFESSIONAL SERVICES SPS 327.41
camping unit, the cooling requirements of this section shall be
met.
(1) DISTRIBUTION SYSTEMS. Distribution systems shall be
sized and located to satisfy the heating and cooling loads of each
conditioned space.
(2) VENTILATION. (a) General. 1. All exhaust vents shall
terminate outside the camping unit.
2. Automatic or gravity dampers that close when the system
is not operating shall be provided fo