Plan Commission — Agenda Packet
City of Fort Atkinson · Jefferson County · Plan Commission · meeting of Sep 22, 2026 · Agenda packets
Open the original document More from City of Fort Atkinson
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
PLAN COMMISSION MEETING
IN PERSON AND VIA ZOOM
TUESDAY, SEPTEMBER 22, 2026 – 4:00 PM
CITY HALL – SECOND FLOOR
https://us02web.zoom.us/j/82214860406?pwd=TEVyUVdQM05VNFVzb0E2TUNTVnZlZz09
Meeting ID: 822 1486 0406
Passcode: 53538
Dial by Location
+1 312 626 6799
If you have special needs or circumstances which may make communication or accessibility
difficult at the meeting, please call (920) 397-9901. Accommodations will, to the fullest extent
possible, be made available on request by a person with a disability.
AGENDA
1. Call meeting to order
2. Roll call
3. New Business
a. Review and possible action relating to the minutes of the August 25, 2026, Plan
Commission meeting (Ebbert, Clerk/Treasurer/Finance Director)
b. Review and possible action relating to a Site Plan Review for the property located
at 815 Jefferson St. (226-0614-3432 and 226-0614-3432-004) (SPR-2026-12)
(Draeger, Director of Neighborhood and Building Services)
c. Update on previously approved projects (Houseman)
4. Adjournment
Date Posted: September 18, 2026
CC: Plan Commission, City Council; City Staff; City Attorney; News Media; Fort Atkinson School
District; Fort Atkinson Chamber of Commerce
Notice is hereby given that a majority of the Fort Atkinson City Council may be present at this
meeting at the location and time indicated above to gather information about any subject
Page 1 of 161
matters on this agenda over which they have decision-making responsibility. This may constitute
a meeting of the City Council pursuant to State ex rel. Badke v. Greendale Village Bd., 173
Wis.2d. 553, 494 N.W.2d 408 (1993), and must be noticed as such although the City Council will
not take any formal action at this meeting.
Visit us online! City news and information can be found at www.fortatkinsonwi.gov, and be sure
to follow us on Facebook @FortAtkinsonWI.
Page 2 of 161
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
PLAN COMMISSION MEETING
IN PERSON AND VIA ZOOM
TUESDAY, AUGUST 25, 2026 – 4:00 PM
CITY HALL – SECOND FLOOR
MINUTES
1. Call meeting to order
Chairperson Manager Houseman called the meeting to order at 4:00 pm.
2. Roll call
Present: Chairperson Manager Houseman, Director of Public Works Navin, Commissioners
Ciccarelli, Shull, Schultz, and Council Representative Huckabee. Also present: Deputy Clerk, and
City Attorney.
Absent: Director of Neighborhood and Building Services
3. New Business
a. Review and possible action relating to the minutes of the August 11, 2026, Plan
Commission meeting (Ebbert, Clerk/Treasurer/Finance Director)
Huckabee moved, seconded by Schultz, to approve the minutes of the August 11, 2026
Plan Commission meeting. The motion carried, 6-0.
b. Review and possible action relating to a Conditional Use Permit for a property located on
Mehta Lane, known as Cardinal View Crossing (parcels 226-0614-3231-000 and 226-0614-
3242-001) (ZMA-2026-01) (Draeger, Director of Neighborhood and Building Services)
Manager Houseman presented the request relating to a Conditional Use Permit for a
group development to allow multiple buildings on the property located on Mehta Lane.
The CSM and Site Plan were approved by the Plan Commission on August 11, 2026,
contingent upon approval of the Conditional Use Permit. The proposed project involves a
CSM to combine two existing parcels, a conditional use permit for group development,
and a Site Plan Review. Each multifamily building is proposed to be identical, two stories in
height, with individual units, attached garages, and entries for a total of 72 units. Multiple
surface parking areas are provided for guests and residents that are connected via internal
circulation driveways. The subject properties are located on the far Northwest side of Fort
Atkinson, adjacent to the USH 26 Bypass on Mehta Lane and Commonwealth Drive.
The developer is also requesting Tax Incremental Financing (TIF) assistance. The Economic
Development Commission recommended approval of the TIF request, with the City
Page 3 of 161
Council expected to review the Development Agreement on September 1, 2026.
Huckabee motioned, seconded by Schultz to recommend approval of the Conditional Use
Permit, subject to the following conditions:
1. All conditions approved by the Plan Commission relating to the Certified Survey Map
and Site Plan Review are incorporated into the final development plans, and
2. Any other recommendations from City staff and the Plan Commission.
Motion carried, 6-0.
c. Review and possible action relating to a Conditional Use Permit for a property located at
550 McMillen St., known as River Point Commons (ZMA-SPR-2026-02) (Draeger, Director of
Neighborhood and Building Services)
Manager Houseman presented the Conditional Use Permit application for the proposed
multi-family development on the property located at 550 McMillen St. The CSM and Site
Plan were approved by the Plan Commission on August 11, 2026, contingent upon
approval of the Conditional Use Permit. The proposed development includes combining
two parcels; four three-story multi-family buildings totaling 96 units; an accessory
office/mailroom building; green space and a dog run; underground and surface parking;
internal driveways and sidewalks; stormwater management areas; and access from both
McMillen Street and Schumacher Way. The development also provides substantial buffers
from existing single-family homes to the north and south.
The developer is also requesting Tax Incremental Financing (TIF) assistance. The Economic
Development Commission recommended approval of the TIF request, with the City
Council expected to review the Development Agreement on September 1, 2026.
Shull moved, seconded by Ciccarelli to recommend approval of the Conditional Use
Permit, subject to the following conditions:
1. All conditions approved by the Plan Commission relating to the Certified Survey Map
and Site Plan Review are incorporated into the final development plans, and
2. Any other recommendations from City staff and the Plan Commission.
Motion carried, 6-0.
d. Review and possible recommendation to the City Council relating to a Certified Survey
Map, for the property located at 1704 Montclair Pl. (CSM-2026-13) (Draeger, Director of
Neighborhood and Building Services)
Director of Public Works Navin presented the Certified Survey Map for 1704 Montclair Pl.
The proposal would divide the existing DR-8 Duplex Residential lot into two lots to allow
construction of a twin house using the zero-lot-line zoning mechanism. Utilities have been
designed to serve the separate lots in accordance with City requirements. The proposal is
consistent with the City’s Comprehensive Plan and residential designation for the area.
Public notice is not required.
Huckabbe motioned, seconded by Ciccarelli to recommend that the Plan Commission
recommend the City Council approve this preliminary Certified Survey Map, subject to
Page 4 of 161
inclusion of the following conditions:
• A joint maintenance agreement for the roof, shared wall of the house, and any
shared portion of the sanitary lateral to be recorded on each parcel,
• All changes noted in the staff report, and
• Any other recommendations from City staff and the Plan Commission
Motion carried, 6-0.
e. Review and possible recommendation to the City Council on a Certified Survey Map for the
property located at 1911 Janesville Avenue, known as River Trail Flats (parcel
226-0514-1742-001) (SPR-2026-07) (Draeger, Director of Neighborhood and Building
Services) Director of Public Works Navin presented the Certified Survey Map and Site Plan
review for the property at 1911 Janesville Avenue, to split the 12-acre parcel into three
new parcels, rezoning from RH-35 to MRH-30, Conditional Use Permit for a Group
Development, and Site Plan for a 12-acre property near Klement Business Park and the
STH 26 Bypass/Janesville Avenue interchange. The Plan Commission approved the
Conditional Use Permit contingent on the approval of the Site Plan by the Plan
Commission and CSM by the City Council at the Plan Commission meeting on August 11,
2026
The development is proposed in two phases, totaling seven two-story multi-family
buildings and 112 units. Phase 1 includes four 16-unit buildings for a total of 64 units (Lot
1), a new Janesville Avenue access, parking, internal drives, and stormwater management.
Phase 2 would include three additional 16-unit buildings for a total of 48 units (Lot 3). The
existing single-family home would remain on a separate 0.9-acre parcel (Lot 2). The
Conditional Use Permit applies to Phase 1; Phase 2 will require a separate Conditional Use
Permit.
Note that the developer will be asking for Tax Incremental Financing assistance for the
project. The Economic Development Commission has reviewed the TIF request in the
Development Agreement and recommended approval of such to the City Council. The City
Council is expected to review the Development Agreement at the meeting on September
1, 2026. Additionally, the developer will be required to obtain a Wisconsin Department of
Natural Resources (DNR) Construction Site Storm Water Discharge General Permit before
commencing construction activities.
Huckabee motioned, seconded by Schultz to recommend the Plan Commission
recommend the City Council approve the Certified Survey Map, subject to the following
conditions:
1. All City Engineer comments are incorporated within a revised CSM and provided to
City staff for review and approval.
2. An access easement is shown over the 6-foot wide trail access over the proposed Lot
3. Any other recommendations of City staff and the Plan Commission.
Motion carried, 6-0.
Page 5 of 161
f. Review and possible action relating to a Site Plan Review for the property located at 1911
Janesville Avenue, known as River Trail Flats (parcel 226-0514-1742-001) (SPR-2026-07)
(Draeger, Director of Neighborhood and Building Services)
Ciccarelli stated that he would like to see a glacial river trail connection to the business
park and a direct connection through the development. Houseman explained that staff
have discussed trail connectivity with the developer; however, a public trail connection
through the private development is unlikely due to liability concerns. She noted that the
city-owned trail is subject to recreational immunity, which generally protects the city from
liability for injuries occurring on the recreational trail.
Huckabee motioned, seconded by Schultz to recommend approval of the Site Plan Review
for Phase 1, subject to the following conditions:
1. Provide interior pathways to connect each building using sidewalks or marked paths
for pedestrian safety
2. Install curbing in all locations where parking and interior landscaping is present
3. Screen all building mechanicals, subject to review by the Zoning Administrator
4. Approval of a Certified Survey Map creating three parcels
5. Approval of a Conditional Use Permit for multiple principal buildings on one parcel
for Phase 1 (approved 8/11/26)
6. Any other recommendations from City staff and the Plan Commission
Motion carried, 6-0.
g. Update on previously approved projects (Houseman)
None.
4. Adjournment
Ciccarelli moved, seconded by Huckabee to adjourn. Meeting adjourned at 4:23 p.m.
Respectfully submitted,
Courtney Thom
Deputy Clerk
Page 6 of 161
City of Fort Atkinson
City Manager's Office
101 N. Main Street
Fort Atkinson, WI 53538
SITE PLAN REVIEW
REPORT TO THE PLAN COMMISSION
DATE: August 11, 2026 FILE NUMBER: SPR-2026-12
PROPERTY ADDRESS: 815 Jefferson St. EXISTING ZONING: Light Industrial
PARCEL NUMBER: 226-0614-3432-002 PROPOSED ZONING: No change
OWNER: Opportunities, Inc. of Jefferson County EXISTING LAND USE: Industrial
APPLICANT: Opportunities, Inc. of Jefferson County REQUESTED USES: Light Industrial, Active
Outdoor Recreation, and On-Site Parking Lot
BACKGROUND
Section 15.10.42 of the City of Fort Atkinson Zoning Ordinance outlines the requirements for
the Site Plan application. This requires review of the proposed development’s building
configuration, site layout and access, parking, exterior building design, landscaping, grading and
erosion, stormwater, exterior lighting, signage, and operational plan.
REQUEST OVERVIEW
Opportunities Inc. is a nonprofit employment service organization that operates commercial
manufacturing, packaging, fulfillment, and warehousing services located on the north side of Fort
Atkinson. The organization is looking to add an outdoor activity area to its campus for its employees.
The subject property was recently approved for a CSM to combine two lots into a new 3.2-acre site
with road frontage on three sides: Jefferson Street, E. Cramer Street, and Clearance Street. The new
site includes two structures, on-site parking, and an east-west internal driveway connection between
Jefferson Street and Clarence Street.
The proposed project is located on the southern end of the site (blue) and includes the construction
of a new outdoor recreational space, off-street parking on either side, and reuse of the existing
structure.
Within the Zoning Ordinance, only new additions, improvements, and development are subject to the
requirements of the ordinance. This memo reviews only those proposed new features within the
disturbance area portion of the site.
The site layout is required to meet the minimum dimensional standards of the zoning district. The
proposed improvements meet these requirements, as shown below.
Page 7 of 161
Requirement Size Proposed Development
Minimum Front Setback 25 feet >25 feet
Minimum Side Setback 10 feet >10 feet
Minimum Street Side Setback 25 feet >25 feet
Maximum Principal Building Height 65 feet N/A
Minimum Principal Building Separation 10 feet >10 feet
Minimum Pavement Setback (lot line to
pavement, excludes driveway entrances)
Side: 5 feet
ROW: 10 feet
Side: 5 feet
ROW: 10 feet
Maximum Impervious Surface Ratio 80% 73.75%
Maximum Building Coverage 70% +/-10%
Accessory Structure Front Setback 60 feet >60 feet
Accessory Structure Side Setback 3 feet >3 feet
Accessory Structure Maximum Height 45 feet <45 feet
The existing Light Industrial land use is permitted by right within the LI, Light Industrial zoning district.
The proposed new land use on-site include: Active Outdoor Recreation and On-Site Parking Lot. Both
land uses are permitted by-right within the Light Industrial zoning district. Land use requirements
include:
On-Site Parking Lot
• Access and vehicular circulation shall be designed to prevent cut-through traffic = met (two
separate parking areas that are not connected)
Active Outdoor Recreation
• Each location shall have appropriate hours of use and comply with the noise provisions of Article
VI Performance Standards = Met
• Facilities using recreational facility night lighting and adjoining a residentially zoned property shall
install and continually maintain a bufferyard with a minimum opacity of 0.60. Said bufferyard shall
be located at the property line adjacent to said residentially zoned property. = N/A (not abutting
residential)
• All structures, paved areas, and active recreational improvements such as sandboxes, tot lots,
tennis courts, and baseball backstops shall be located a minimum of 25 feet from any residentially
zoned property. = N/A (not abutting residential)
• Facilities which serve a regional or community-wide function shall provide an off-street passenger
loading area if the majority of the users will be children or senior citizens. = N/A (not intended for
Page 8 of 161
these purposes)
• Minimum required parking: Generally, one space is required per four expected patrons at
maximum capacity for any use requiring over 5 spaces. However, the following specific
requirements apply.
o Athletic facilities: one space per employee on the largest work shift, plus one space per 4
patrons (participants and spectators) at maximum capacity.
o Tot lots, fitness courses, and parks: no parking spaces required.
o The Zoning Administrator has the ability to require a parking study to increase or reduce
parking requirements for any combination of the above uses.
There is a total of 57 proposed new on-site parking stalls. The East parking area is intended for
visitors of the playground and the West parking area is intended to become additional employee
parking. As shown above, tot lots, fitness courses and parks have no minimum parking requirements.
Additionally, the Zoning Administrator has the ability to increase or reduce requirements based on
the specific needs of the proposed facility.
The northern portion of the site is an existing legal nonconforming property, with structures and
pavement established before the current zoning regulations. All new improvements are required to
comply with applicable site design standards.
The proposed project has submitted required elements of the Site Plan review that are included
within the attachment. Below is a review of the various other zoning standards that are required with
the proposed development:
Access and Visibility Standards (Section 15.06.03, 15.06.04, and 15.06.05)
• Multiple access points from one street can be approved through the Site Plan process on lots
greater than 200 feet long = not met (new access points proposed and greater than two exist
today Plan Commission must approve)
• No access is permitted within 50 feet of an intersection = met
• Maximum driveway size is 24 feet wide, unless greater is needed for fire access = met
• At least one ped/bicycle access point to at least one street frontage is required = met (the
playground is private and access is provided to the facility to the North)
• All structures must be located outside of vision triangle at intersections = met
Page 9 of 161
Parking and Loading Standards (Section 15.06.06 and 15.06.07)
• All drive isles, driveways, and parking areas must be constructed of a hard surface = met
• Curbs are required adjacent to buildings, planting islands, required front yards, and where
necessary to prevent vehicles from extending into pedestrian paths or rights-of-way = not met
(only curbing shown between Clarence Street parking lot and outdoor recreational area)
• All parking stalls must provide pavement markings = met
• Throat depth (distance between street access and traffic circulation area/parking area must be a
minimum of 25 feet) = met
• Minimum parking stall dimensions are required to be 9 feet wide and 18 feet long = met
• Minimum parking isles widths are required to be 24 feet wide = met
• Minimum and maximum off-street parking stalls requirements = see above
• A minimum of 7 on-site bicycle stalls are required = not met (applicant has indicated the
willingness to add the bicycle stalls)
• Loading areas shall not be located within the front yard, within 50 feet of residential zoned
property, or be located within 25 feet of an intersection = not met (located within the front yard)
• Loading areas shall be a minimum of 10 feet wide and 50 feet long = met
Exterior Lighting Standards (Section 15.06.20)
• At the property line, a maximum of 1.0 footcandle is required = met
• The average lighting on-site is required to be a maximum average of 3.0 footcandles = met
• All vehicular parking, loading, and circulation areas are required to provide a minimum intensity
of 0.4 footcandles in those areas = met
• The maximum height of all freestanding light fixtures required is 30 feet = met (12–16 ft in height)
• All exterior light fixtures are full cut-off and downward facing = met (staff will need to confirm
Page 10 of 161
that motion lighting will not be pointed towards neighboring properties)
Outdoor Storage and Screening Standards (Section 15.06.21)
• All trash containment structures are required to be enclosed, a minimum of 6 feet in height, and
made of solid wood with an access gate = unknown
Fencing Standards (Section 15.06.40)
• Materials permitted include wood, brick, stone, wrought iron, vinyl, and chain link = met (vinyl
and steel)
• Maximum fence height is 4 feet in front/street yards and 6 feet in side/rear yards = met (6 ft vinyl
side yard and 4 foot steel around activity area)
Landscaping Standards (Section 15.08.30)
Point values are provided for each type of plant and the amount required in each portion of the site is
listed within the Zoning Ordinance. This provides the developer with options in customizing the
planting selection and location to best fit the project and site.
• 0 landscaping points are required for the building foundation = N/A
• 300 landscaping points are required for the paved surface areas = met
• 400 landscaping points are required for the street frontage = met
• 0 landscaping points are required for the yards = N/A
Exterior Building Design Standards (Section 15.07.40)
There are defined exterior building design standards for different types of uses in the Zoning Code.
This project is proposed to be an institutional land use in the Institutional Zoning District.
Additionally, the design standards classify the following materials by type: Class I (brick, stone, glass),
Class II (block, EIFS, stucco), Class III (siding, wood, decorative metal panels), or Class IV
(nondecorative metal panels or concrete panels).
• Minimum 50% Class I materials on the total building facade = not met
• Rear building elevations not facing a public street or parking lot are exempt
• Class I, II, or II materials permitted, Class IV prohibited = met
• Façade articulation shall be included every 70 feet = met
• Building orientation toward the road and appearance of front façade as entryway = met
Page 11 of 161
• Rooftop mechanicals visible from adjacent public rights-of-way shall be screened = unknown
Post Construction Stormwater Management (Ordinance 18-190)
This ordinance follows state law for all developments with greater than 1 acre of disturbance. The
ordinance manages stormwater based upon sites characterized as new construction, redevelopment,
or in-fill. The ordinance requires the development’s stormwater leaving the site be controlled among
three categories, volume (peak runoff), TSS (total suspended solids) and infiltration.
Construction Site Erosion Control Plan (Ordinance 18-189)
This ordinance follows requires certain levels of control during construction to reduce the movement
of sediment (dirt) off the construction site and into local waterways (Rock River, Bark River, Allen
Creek).
The submitted stormwater management plan and the erosion control plan generally comply with
State and City requirements. To ensure full compliance before final approval, the applicant is
coordinating with the Director of Public Works and the City Engineer to finalize and record a
Stormwater Maintenance Agreement, which must be fully executed and recorded prior to issuing any
construction permits.
Due to site constraints and desired development, the applicant will utilize an underground
stormwater infiltration system installed beneath the East parking area to assist with stormwater
management requirements.
Required Plan Revision Areas Include:
• Inlet-Capacity Calculations: Detailed hydrological calculations demonstrating that all
proposed inlets can sufficiently capture anticipated peak runoff rates.
• 100-Year Event Overflow Route: A clearly defined, unobstructed overland flow path mapped
to safely convey stormwater during a 100-year storm event without threatening adjacent
structures.
• Driveway Apron Specifications: Design details updated to explicitly align with City standard
engineering drawings and construction specifications.
• Accessible Route Integration: Detailed grading and elevation plans ensuring continuous,
compliant accessible routes leading directly from designated accessible parking stalls.
Page 12 of 161
PUBLIC NOTICE
Public Notice is not required.
COMPREHENSIVE LAND USE PLAN (2019):
The subject parcel is located within the North Railway District Planning Area (see Attachments)
and is identified for Employment uses within the Plan. The future development and
redevelopment concepts identified in the Plan emphasize the continued presence of industrial
and employment opportunities within the area.
The subject property is also designated General Industrial on the Future Land Use Map. This
designation accommodates a range of uses, including indoor manufacturing, warehousing and
distribution, and office uses. The proposed outdoor activity area is intended to function as an
accessory amenity to the existing industrial and employment use and does not alter the
predominant land use of the property.
The proposed addition represents an investment in the site that provides enhanced amenities
and recreational space for employees, contributing to employee quality of life and a positive
work environment. The addition also provides a beneficial amenity within the industrial campus
while remaining compatible with the established industrial use. Staff believes the proposal is
consistent with the intent of the Comprehensive Plan and supports the continued vitality of the
North Railway District.
DISCUSSION
Opportunities Inc. is a valued local company and an important community resource. The
proposed improvements will provide benefits to both the community and the organization’s
employees. Staff recognizes the positive community impacts associated with the project.
Staff notes that certain aspects of the proposed building materials do not fully meet the
requirements of the ordinance. However, the project involves an existing building and
represents a significant improvement to the property, as well as a significant investment by the
applicant. Given the existing conditions of the site and building, and considering the overall
scope and quality of the proposed improvements, City Staff finds that the intent of the
ordinance is being met through the proposed project. The proposal also includes an additional
access point to Clarence Street. Staff discussed the proposed access with the applicant and
understands that the access is intended to address employee safety and site circulation
concerns. The applicant indicated that employee transportation currently uses the alley
connection between Jefferson and Clarence Streets as a primary pick-up and drop-off location.
The additional Clarence Street access would provide an alternative point of access and is
intended to prevent potential safety issues. Staff considers the proposed access to be a
reasonable site improvement given the existing circulation pattern and the safety concerns
identified by the applicant. While there are a few outstanding items that still need to be
addressed, staff supports the project overall and recognizes the substantial improvements,
Page 13 of 161
safety considerations, and community benefits associated with the applicant’s investment in
the property.
The City’s Management Team has reviewed the application, and all comments have been
included within this document.
RECOMMENDATION
City staff recommends approval of the Site Plan, subject to the following conditions:
• Require the applicant to provide the following information that meets all the requirements
of the Zoning Code to be reviewed by City staff:
o Add curbing to meet the minimum requirements
o Add on-site bicycle parking to meet the minimum requirements
o Provide a trash enclosure plan compliant with Section 15.06.21
o Provide the location of building mechanicals and screening if necessary
o Execute a Stormwater Management Agreement with the City
• Waive the requirement for any loading areas to be located outside the front yard setback
(the existing building on the south end of the site is not proposed to change and is currently
located approximately 25 feet from the property line, creating limited space to
accommodate the proposed new loading area outside that setback).
• Approve the new access point from Clarence street as proposed
• Require the recording of the previously approved CSM
• Any other recommendations of City staff and the Plan Commission.
ATTACHMENTS
1. 2026 Site Plan Review Appl_Redacted
2. 2026.09.03 Opport Inclusive Park Renderings
3. Opportunities Civil Plans 9.4.26
4. Playground layout and Site-200 A0.0
5. Opportunities 815 Jefferson Street
6. Landscaping_Opportunities 815 Jefferson Street
7. Grading & Erosion Control Plan 8.27.26
8. Opportunities Development Storwater Review_9.17.26
9. Opprotunities Inc - SWM Memo 2026.09.04
10. Photometrics_StrucRite_Opportunities Rec_ES1.0P_20260911
11. dsx0_Lighting
12. hgx_Lighting
13. rad1_Lighting
14. rcny_Lighting
15. wdge2_Lighting
Page 14 of 161
Page 15 of 161
Page 16 of 161
Page 17 of 161
Page 18 of 161
Page 19 of 161
Page 20 of 161
NORTH 72°25'55" WEST 251.05'
NORTH 17°32'36" EAST 485.86'SOUTH 22°14'26" WEST 511.67'
9/4/2026
C1.01
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
EXISTINGCONDITIONS &REMOVALSPLANEJQLJKKJP
Page 21 of 161
REF.
slab ~ -1.5"
slab ~ -1.0"
GAS
NEWOHD
RECREATIONAREA
?sprinkler riser?WH
STORAGE
BENCH
MECHANICAL
WATERFOUNTAIN
NORTH 72°25'55" WEST 251.05'
NORTH 17°32'36" EAST 485.86'SOUTH 22°14'26" WEST 511.67'
9/4/2026
C1.02
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
PROPOSEDSITE PLANEJQLJKKJP
Page 22 of 161
REF.
slab ~ -1.5"
slab ~ -1.0"
GAS
NEWOHD
RECREATIONAREA
?sprinkler riser?WH
STORAGE
BENCH
MECHANICAL
WATERFOUNTAIN
NORTH 72°25'55" WEST 251.05'
NORTH 17°32'36" EAST 485.86'SOUTH 22°14'26" WEST 511.67'
9/4/2026
C1.03
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
GRADING &EROSIONCONTROLPLANEJQLJKKJPDIGGERS HOTLINEDial or (800)242-8511www.DiggersHotline.com
Page 23 of 161
REF.
slab ~ -1.5"
slab ~ -1.0"
GAS
NEWOHD
RECREATIONAREA
?sprinkler riser?WH
STORAGE
BENCH
MECHANICAL
WATERFOUNTAIN
NORTH 72°25'55" WEST 251.05'
NORTH 17°32'36" EAST 485.86'SOUTH 22°14'26" WEST 511.67'
9/4/2026
C1.04
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
UTILITY PLANEJQLJKKJPDIGGERS HOTLINEDial or (800)242-8511www.DiggersHotline.com
Page 24 of 161
9/4/2026
C1.05
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
UNDERGROUNDDETENTIONPLANKJPKJPKJP
Page 25 of 161
9/4/2026
C2.00
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
CONSTRUCTIONNOTESEJQLJKKJP
Page 26 of 161
1. 6.
7.
2.
5.
4.8.
3.
9/4/2026
C2.02
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
EROSIONCONTROLDETAILSKJPKJPKJP
Page 27 of 161
9/4/2026
C2.01
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
SITE DETAILSEJQLJKKJP
Page 28 of 161
9/4/2026
C2.03
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
UTILITYDETAILSKJPKJPKJP
Page 29 of 161
PAVILION
RECREATION BUILDING
EXISTING BUILDING
EXISTING DROP OFF LANE
ENTRANCE GATE
SEE CIVIL DRAWINGS FOR PARKING
SEE CIVIL DRAWINGS FOR PARKING
STEEL FENCE
STEEL FENCE
STE
EL FENCE
GATE
EXISTING
DUMPSTER
HVAC
JEFFERSON STREET
CLARENCE STREET
SEE CIVIL DRAWINGS DRIVE AISLES
A
C
B
B
B
B
A
F
F
F
D
F
F
F
D
E
GATE
6' - 0" 2' - 0"
2' - 0" 8' - 0"
RAISED GARDEN BEDS
(3) 6FT & (2) 8FT
JOB NUMBER:
DRAWN BY:
SHEET NUMBER:
© 2026 STRUCRITE , INC.
ISSUED DATE:
707 N. Grand Ave. - Suite 102
Waukesha, WI 53186
262.549.3222 - www.srdinc.biz
SHEET TITLE:
REVISIONS
9/3/2026 7:19:33 PM
25218
KS
A0.0
ARCH SITE PLAN
07.28.2026
PLAN COMMISSION
Opportunities, Inc. Rec Building
815 Jefferson St.
Fort Atkinson, WI
NORTH
SOUTH FENCE
6' WHITE PVC
STEEL PARK FENCE
4' TITAN 3 -RAIL w/ RINGS
No. DATE DESCRIPTION
1/4" = 1'-0" 2 ENTRY GATE
1/2" = 1'-0" 3 CLOCK
A - GREEN
B - ORANGE
C - GRAY
TURF COLORS
D - ?
E - ?
F - ?
CONCRETE COLORS
Page 30 of 161
1a
e1
DOOR TAG
WINDOW TAG
WALL TAG
EMERGENCY EXIT SIGN
EXISTING CONSTRUCTION
NEW CONSTRUCTION
6"
( 6" )
TYPICAL DIMENSION
FINISH TO FINISH
DIMENSION SHOWING
FRAMING TO FRAMING
FIRE EXTINGUISHER
PROJECT KEYED NOTE ?
101
JOB NUMBER:
DRAWN BY:
SHEET NUMBER:
© 2026 STRUCRITE , INC.
ISSUED DATE:
707 N. Grand Ave. - Suite 102
Waukesha, WI 53186
262.549.3222 - www.srdinc.biz
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN CONSTITUTE ORIGINAL
AND UNPUBLISHED WORK OF THE DESIGN
PROFESSIONAL AND MAY NOT BE DUPLICATED,
USED OR DISCLOSED WITHOUT WRITTEN
CONSENT OF STRUCRITE, INC.
DESIGNER/
SUPERVISING PROFESSIONAL
SHEET TITLE:
REVISIONS
SYMBOLS LEGEND LOCATION MAP VICINITY MAP ABBREVIATIONS SHEET INDEX
GENERAL NOTES
7/29/2026 3:18:35 PM
25218
Author
G1.0
Opportunities,
Inc. Rec
Building
815 Jefferson St.
Fort Atkinson, WI
COVER PAGE
07.28.2026
Opportunities, Inc. Rec Building
815 Jefferson St.
Fort Atkinson, WI
StrucRite, Inc.
Boyd E. Coleman, P.E.
President, Engineer
707 N. Grand Ave. - Suite 102
Waukesha, WI 53186
262.549.3222
PLAN COMMISSION
PLAN COMMISSION
1-GENERAL
G1.0 COVER PAGE
2-CIVIL
C1.00 TITLE SHEET
C1.01 EXISTING CONDITIONS PLAN
C1.02 PROPOSED SITE PLAN
C1.03 GRADING & EROSION CONTROL PLAN
C1.04 UTILITY PLAN
C1.05 LANDSCAPE PLAN
C2.00 CONSTRUCTION NOTES
C2.01 SITE DETAILS
3-ARCHITECTURAL
A0.0 ARCHITECTURAL SITE PLAN
A1.0 RECREATION BUILDING
A1.1 PAVILION
A2.0 EXTERIOR ELEVATIONS
5-ELECTRICAL
ES1.0P ELECTRICAL SITE LIGHTING & PHOTOMETRICS
1. ALL WORK SHALL COMPLY WITH ALL LOCAL, STATE & NATIONAL CODES HAVING
JURISDICTION OVER THIS PROJECT.
2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH BUILDING REGULATIONS AND IN
A QUALITY WORKMANSHIP MANNER
3. DO NOT SCALE DRAWINGS
4. SEE GENERAL CONDITIONS OF THE CONTRACT FOR FULL SCOPE OF PROJECT
5. UNLESS NOTED OTHERWISE, ALL DETAILS, SECTION AND NOTES ON THE
DRAWINGS ARE INTENDED TO BE TYPICAL FOR SIMILAR SITUATIONS ELSEWHERE
6. THE PLANS AND SPECIFICATIONS ARE INTENDED TO GIV E A DESCRIPTION OF THE
WORK. NO DEVIATION FROM THE PLANS AND SPECIFICATION S SHALL BE MADE
WITHOUT THE WRITTEN CONSENT OF STRUCRITE, INC.
7. ANY DISCREPANCIES WITHIN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE ATTENTION OF STRUCRITE, INC. IN WRITING.
8. THE TERMS "NOT IN CONTRACT" OR "BY OWNER" OR "BY OTHERS" DO NOT
PRECLUDE OTHER WORK ASSOCIATED WITH THE CONTRACT WHICH MUST OCCUR
IN THE VICINITY OF THE AREA OR THROUGH THE SPACE.
9. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS
AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES BETWEEN EXISTING
CONDITIONS AND THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE
ATTENTION OF STRUCRITE, INC PRIOR TO BIDDING.
10. IF FIELD CONDITIONS NECESSITATE ANY CHANGES OR MODIFICATIONS, THE
CHANGES OR MODIFICATIONS MUST BE APPROVED BY STRUCRITE, INC. PRIOR TO
PROCEEDING WITH WORK.
11. ALL CHANGE ORDERS MUST BE APPROVED BY THE OWNER PRIOR TO
PROCEEDING WITH ANY WORK. FAILURE TO FOLLOW THIS STEP MIGHT RESULT IN
NON-PAYMENT.
12. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL CLEAN-UP.
13. GENERAL AND SUB CONTRACTS SHALL EXERCISE ALL REASONABLE
PRECAUTIONS FOR THE PROTECTION OF PERSONS AND PROPE RTY ON THE SITE.
ALL SAFETY PROVISIONS AND APPLICABLE LAWS FOR BUILDING AND
CONSTRUCTION CODES SHALL BE OBSERVED.
14. GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO STRUCRITE INC.
FOR APPROVAL BEFORE PROCEEDING WITH ANY FABRICATION OR INSTALLATION.
15. MANUFACTURES DIRECTIONS FOR APPLICATION, INSTALLATION AND METHODS
SHALL BE FOLLOWED ARE HEREWITH MADE PART OF THE CONSTRUCTION
DOCUMENTS.
16. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY TO BE PRESSURE
TREATED
NORTH
AC AIR CONDITIONING
ACS ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADDM ADDENDUM
ADJ ADJUSTABLE
ADO AUTOMATIC DOOR OPERATOR
AFF ABOVE FINISH FLOOR
ATL ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECT
AUX AUXILIARY
AVG AVERAGE
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
BLKHD BULKHEAD
BM BEAM
BO_ BOTTOM OF (ITEM)
BO BY OTHERS
BS BOTH SIDES
BT JNT BUTT JOINT
BTWN BETWEEN
CAS CARD ACCESS SYSTEM
CB CATCH BASIN
CF/CI CONTRACTOR
FURNISHED/CONTRACTOR
INSTALLED
CG CORNER GUARD
CH COAT HOOK
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CONT CONTINUE, CONTINUOUS
CORR CORRIDOR
CPT CARPET
CRS COURSE, COURSES
CT CERAMIC TILE
CTR CENTER
CUH CABINET UNIT HEATER
DBL DOUBLE
DEFS ERECT APPLIED EXTERIOR
FINISH SYSTEM
DEMO DEMOLITION
DEP DEPRESSED
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DIV DIVISION
DN DOWN
DR OPNGDOOR OPENING
DS DOWNSPOUT
DT DRAIN TILE
DW DISHWASHER
DWG DRAWING
DWR DRAWER
EA EACH
EIFS EXTERIOR INSULATION FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL/ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EP ELECTRICAL PANEL
EQ EQUAL
EQUP EQUIPMENT
ES ELECTRIC STRIKE
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXH FN EXHAUST FAN
EXIST EXISTING
EXP EXPANSION
EXPO EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FGL FIBERGLASS
FHC FIRE HOSE CABINET
FN FINISH
FIXT FIXTURE
FL FLOOR LINE
FLR FLOOR
FLUOR FLUORESCENT
FO_ FACE OF (ITEM)
FOF FACE OF FINISH
FOM FACE OF MASONRY
FP FIRE PROOF, FIRE PROTECTION
FR FRAME
FT FOOT OR FEET
FTG FOOTING
FURG FURRING
FV FIELD VERIFY
GA GAGE
GAL GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GL GLASS
GYP BD GYPSUM BOARD
HB HOSE BIB
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HORZ HORIZONTAL
HP HORSE POWER
HR HOUR
HTR HEATER
HVAC HEATING, VENTILATION & AIR
CONDITIONING
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE, INCLUDING
INT INTERIOR
JAN JANITOR
JNT JOINT
KO KNOCK OUT
KS KNEE SPACE
L LENGTH, LONG
LAV LAVATORY
LBS POUND(S)
LKR LOCKER
LT WT LIGHT WEIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MFR MANUFACTURER
MH MANHOLE
HD MIDDLE
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MSB MOP SERVICE BASIN
MTD MOUNTED
MTL METAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OV OVER
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF/CI OWNER FURNISHED/
CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
PED PEDESTAL
PERIM PERIMETER
PL PLATE
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNL JNT PANEL JOINT
POC POINT OF CONNECTION
PR PAIR
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PT PAINT
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER WITH
RECEPTACLE
PTM PAINT TO MATCH
QT QUARRY TILE
R RADIUS
R RISER
RA RETURN AIR
RD ROOF DRAIN
REF REFRIGERATOR
REFL REFLECTED
REINF REINFORCED
REQD REQUIRED
REV REVISION
RFI REQUEST FOR INFORMATION
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RTU ROOF TOP UNIT
SAB SOUND ATTENUATION BATTS
SAG SUPPLY AIR GRILL
SC SOLID CORE
SCHED SCHEDULE
SD SOAP DISPENSER
SECT SECTION
SHR SHOWER
SHT SHEET
SHT MTLSHEET METAL
SHV SHELF, SHELVING
SIM SIMILAR
S&P SHELF & POLE
SPEC SPECIFICATION
SPKR SPEAKER
SQ SQUARE
SS SOLID SURFACE
SSK SERVICE SINK
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
T TREAD
TEMP TEMPORARY
T&G TONGUE & GROOVE
THK THICKNESS
TLT TOILET
TO_ TOP OF (ITEM)
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOP TOP OF PAVEMENT
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TYP TYPICAL
UCR UNDERCOUNTER REFRIG.
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UR URINAL
VAV VARIABLE AIR VOLUME
VB VAPOR BARRIER
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VR VAPOR RETARDER
VWC VINYL WALL COVERERING
w/ WITH
WC WATERCLOSET
WD WOOD
WF WIDE FLANGE
WH WATER HEATER
w/o WITHOUT
WS WORKSTATION
WWF WELDED WIRE FABRIC
WWM WEEDED WIRE MESH
YD YARD(S)
NORTH
No. DATE DESCRIPTION
Page 31 of 161
815 JEFFERSON STREETFORT ATKINSON, WI 53538OPPORTUNITIES INC. RECREATION AREA
DIGGERS HOTLINEDial or (800)242-8511www.DiggersHotline.com7/28/2026C1.00122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
TITLE SHEETEJQLJKKJP
Page 32 of 161
7/28/2026C1.01122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
EXISTINGCONDITIONS &REMOVALSPLANEJQLJKKJP
Page 33 of 161
PAVILION
RECREATION BUILDING
EXISTING BUILDING
EXISTING DROP OFF LANE
ENTRANCE
GATE
SEE CIVIL DRAWINGS FOR PARKING
A0.0
2
SEE CIVIL DRAWINGS FOR PARKING
STEEL FENCE
STEEL FENCE
STEEL FENCE
GATE
EXISTING
DUMPSTER
HVAC
JEFFERSON STREET
CLARENCE STREET
A0.0
3
JOB NUMBER:
DRAWN BY:
SHEET NUMBER:
© 2026 STRUCRITE , INC.
ISSUED DATE:
707 N. Grand Ave. - Suite 102
Waukesha, WI 53186
262.549.3222 - www.srdinc.biz
SHEET TITLE:
REVISIONS
7/29/2026 3:09:18 PM
25218
KS
A0.0
ARCH SITE PLAN
07.28.2026
PLAN COMMISSION
Opportunities, Inc. Rec Building
815 Jefferson St.
Fort Atkinson, WI
1/16" = 1'-0" 1 Site-F.F. Plan Commission
NORTH
SOUTH FENCE
4' WHITE PVC STEEL PARK FENCE
4' TITAN 3 -RAIL w/ RINGS
No. DATE DESCRIPTION
1/4" = 1'-0" 2 ENTRY GATE
1/4" = 1'-0" 3 CLOCK
Page 34 of 161
REF.
slab ~ -1.5"
slab ~ -1.0"
GAS
NEW
OHD
79' - 9"
24' - 0" 13' - 0 1/4"
RECREATION
AREA
?sprinkler riser?
WH
STORAGE
3' - 8"
5' - 6"
4' - 6"
BENCH
MECHANICAL
16' - 0"
WATER
FOUNTAIN
11' - 2 7/8"
6' - 7 5/8"
10' - 10 7/8"
9' - 1 5/8"
6' - 5 1/4"
41' - 6 1/2"
CANOPY ABOVE
JOB NUMBER:
DRAWN BY:
SHEET NUMBER:
© 2026 STRUCRITE , INC.
ISSUED DATE:
707 N. Grand Ave. - Suite 102
Waukesha, WI 53186
262.549.3222 - www.srdinc.biz
SHEET TITLE:
REVISIONS
7/29/2026 2:07:45 PM
25218
Author
A1.0
RECREATION BUILDING
07.28.2026
PLAN COMMISSION
Opportunities, Inc. Rec Building
815 Jefferson St.
Fort Atkinson, WI
TRUE
NORTH
1/4" = 1'-0" 1 1st LEVEL PLAN - RECREATION BUILDING
No. DATE DESCRIPTION
Page 35 of 161
GENERAL PLAN NOTES:
1. SEE SHEET A5.0 FOR ALL TYPICAL MOUNTING HEIGHTS AND DOOR CLEARANCES.
2. NOT USED
18' - 2 3/8" 17' - 9 5/8"
24' - 0"
36' - 0"
COVERED
PATIO STORAGE
EXISTING EPDM RETROFIT ROOF TO REMAIN
REMOVE HOIST
1st LEVEL
100' - 0"
ARCTIC WHITE A -TYPE SEMI
CONCEALED WALL PANEL CARBON GRAY TRIM
1st LEVEL
100' - 0"
OPEN TO COVERED PATIO
1st LEVEL
100' - 0"
ARCTIC WHITE A -TYPE SEMI
CONCEALED WALL PANEL
EXISTING ROOF,
NEW CARBON GRAY TRIM
ALL DEMOLITION BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED.
GENERAL CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS. LOCATIONS OF
WALLS, DOORS, AND OTHER ITEMS HAVE BEEN FIELD MEASURED FOR GENERAL
LAYOUT ONLY. REPORT ANY DISCREPANCIES TO STRUCRITE, INC. FOR
CLARIFICATION PRIOR TO THE START OF WORK.
IF FLOORS, WALLS, OR CEILINGS ARE DAMAGED DURING REMOVAL, THE
CONTRACTOR RESPONSIBLE SHALL PATCH / REPAIR AS REQUIRED TO MATCH
EXISTING OR NEW MATERIAL SURFACES.
AT ALL REMOVAL WORK, INCLUDING FLOORS, WALLS, DOORS, CEILINGS, ETC.,
PATCH ALL WORK AT REMOVAL & NEW CONNECTION; PAINT AS REQUIRED.
AT MECHANICAL WORK, WHERE REMOVAL OF PIPES, CONDUIT, DUCTWORK, ETC.
HAS LEFT AN OPENING OR HOLD THROUGH THE WALL, FLOOR, OR CEILING; FILL &
PATCH OPENING TO MATCH THE ADJACENT CONSTRUCTION AND FINISH AS
REQUIRED.
BEFORE COMMENCING WITH DEMOLITION WORK, REVIEW W/ OWNER WHICH ITEMS
ARE TO BE SALVAGED AND TURNED OVER THE OWNER, IN ADDITION TO THOSE
LISTED ON THE PLANS. ANY ITEM NOT WANTED BY THE OW NER SHALL BE
REMOVED FROM THE JOB SITE BY THE GENERAL CONTRACTOR AND DISPOSED OF
IN THE PROPER AND LEGAL MANNER.
SEE MECHANICAL DRAWINGS FOR DESCRIPTION OF REQUIRED MECHANICAL
DEMOLITIONS.
GENERAL DEMOLITION NOTES:
JOB NUMBER:
DRAWN BY:
SHEET NUMBER:
© 2026 STRUCRITE , INC.
ISSUED DATE:
707 N. Grand Ave. - Suite 102
Waukesha, WI 53186
262.549.3222 - www.srdinc.biz
SHEET TITLE:
REVISIONS
7/29/2026 2:28:02 PM
25218
Author
A1.1
PAVILION
07.28.2026
PLAN COMMISSION
Opportunities, Inc. Park Pavilion
815B Jefferson St
Ft. Atkinson, WI
TRUE
1/4" = 1'-0" 2 1st LEVEL NORTH
1/4" = 1'-0" 3 ROOF PLAN
1/4" = 1'-0" 1 1st LEVEL - DEMO
1/4" = 1'-0" 4 EAST ELEVATION
1/4" = 1'-0" 5 NORTH ELEVATION 1/4" = 1'-0" 6 SOUTH ELEVATION
No. DATE DESCRIPTION
Page 36 of 161
ELEVATION GENERAL NOTES:
1. NOT USED
1st LEVEL
100' - 0"
ARCTIC WHITE PANEL
CARBON GRAY PANEL
BRICK VENEER
1st LEVEL
100' - 0"
CARBON GRAY PANEL
HVAC
1st LEVEL
100' - 0"
GLAZED OVERHEAD DOOR
CARBON GRAY PANEL
ARCTIC WHITE PANEL
CARBON GRAY PANEL
ARCTIC WHITE PANEL
BRICK VENEER
JOB NUMBER:
DRAWN BY:
SHEET NUMBER:
© 2026 STRUCRITE , INC.
ISSUED DATE:
707 N. Grand Ave. - Suite 102
Waukesha, WI 53186
262.549.3222 - www.srdinc.biz
SHEET TITLE:
REVISIONS
7/29/2026 2:08:00 PM
25218
Author
A2.0
EXTERIOR ELEVATIONS
07.28.2026
PLAN COMMISSION
Opportunities, Inc. Rec Building
815 Jefferson St.
Fort Atkinson, WI
1/4" = 1'-0" 1 EAST ELEVATION
1/4" = 1'-0" 2 SOUTH ELEVATION
1/4" = 1'-0" 3 WEST ELEVATION
1/4" = 1'-0" 4 NORTH ELEVATION
No. DATE DESCRIPTION
CANYON BRICK SHALE BROWN VENEER
Page 37 of 161
LIGHT FIXTURE SCHEDULE
ABBREVIATIONS:
=DRIVERDW= DRYWALLET = ELECTRONICMG= MAGNETICR=RECESsS = SURFACESP = SUSPENDEDV = VARIES
DM = DIMMINGE = EXPOSEDLG=LAY-IN GRIDOT = OTHERRMREMOTERM = REMOTESD = STEP DIMMINGST =STANDARDWM = WALL MOUNTED
LAMPS/LEDSBALLAST/DRIVER
DWG IDDESCRIPTIONMOUNTING
TYPELUMENSWATTSTYPENO.
XTURE
VOLTAGE
POLE-MOUNTED AREA LIGHT FOR VEHICLE TRAFFIC AREAS OPALED52973500451POLE120/277
-WITH WTH GLARE GLARE SHEILDSHEILD
POLE-MOUNTED AREA LIGHT FOR PEDESTRAIN TRAFFIC AREAS
OPB-3LED4410350038DPOLE120/277 -PATHWAY DISTRIBUTION
POLE-MOUNTED AREA LIGHT FOR PEDESTRAIN TRAFFIC AREAS
OPB-4LED5078350038D1POLE120/277 - FORWARD DISTRIBUTIONTAIR2
MANUFUFACTURERRER PART NUMBER
LITHONIA LIGHTING DSXO LED P2 35K 80CRI T3LG MVOLT XPA
NLTAIR2 PIRHN EGSROR APPROVED EQUIVALENT
LITHONIA LIGHTING RAD1 LED P2 35K PATH MVOLT XPA
NLTAIR2OR APPROVED EQUIVALENT
LITHONIA LIGHTING RAD1 LED P2 35K ASY MVOLT XPAUW
NOTES
1
1 OR APPROVED EQUIVALENT
AXIS LIGHTING EX2R IP66 400 90 35 SO 4 x
ODAOUTDOOR CANOPY LINEAR DOWNLIGHTLED16003500161120/277UNV DPXOR APPROVED EQUIVALENT
1
AXIS LIGHTING EX2R IP66 300 9 1P66 300 90 35 SO 404 xx
ODBOUTDOOR CANOPY LINEAR DOWNLIGHTLED12003500121R120/277UNV DPXOR APPROVED EQUIVALENT
LITHONIA LIGHTING HGX HLED 2RH ALO SWW2WW2 120 PIR
OWAWALL-MOUNTED SECURITY FLOOD LIGHTLED2150400021WM120/277
OR APPROVED о EQUIVALENTED
OUTDOOR EXIT LIGHT OXALED1251350010DWMLITHONIA LIGHTING WDWDGE2 LED P1 35K5K 80CRI VF MVOLTOLT SRM AWS 120/277
WITH TH COLD-WEATHER-RATED EMERGENCY BATTERY BACKUPE20WC PE E20WC PEOR APPROVED EEOUIVALENT1,2
ЕQUIVALENT
SCHEDULE NOTES:
1 CONFIRM FIXTURE WITH ARCHITECT AND OWNER
FIXTURE SHALL BE PROVIDED WITH INTEGRAL PHOTOCELL CONTROL AND COLD-WEATHER-RATED BATTERY, AND SHALLIS
UNSWITCHED CIRCUIT
Page 38 of 161
7/28/2026C1.05122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
LANDSCAPEPLANLJKSLBLJK
Page 39 of 161
REF.
slab ~ -1.5"
slab ~ -1.0"
GAS
NEWOHD
RECREATIONAREA
?sprinkler riser?WH
STORAGE
BENCH
MECHANICAL
WATERFOUNTAIN
8/27/2026
C1.03
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
PRELIMINARYOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
GRADING &EROSIONCONTROLPLANEJQLJKKJP
DIGGERS HOTLINEDial or (800)242-8511www.DiggersHotline.com
Page 40 of 161
CITY OF FORT ATKINSON
Engineering Review Comments
Project: Opportunities, Inc. Recreation Area
Location: 815 Jefferson Street
Review Date: September 17, 2026
Reviewed By: Cory Horton, P.E.
Resubmittal Reviewed:
• Opportunities Civil Plans - Parish Survey & Engineering (September 4, 2026) -
Existing conditions, site, grading, erosion control, utility, underground detention,
notes, and details.
• Stormwater Management Memorandum - Kevin Parish, P.E., Parish Survey &
Engineering (September 4, 2026) - Peak discharge, TSS, HydroCAD, WinSLAMM,
storm sewer, and maintenance information.
• Proposed Site Plan and Grading & Erosion Control Plan - Parish Survey &
Engineering (August 27, 2026).
• Architectural Site Plan / Playground Layout - StrucRite, Inc. (September 3, 2026).
Civil / Stormwater
1. Original Comment: Provide stormwater management calculations demonstrating
compliance with the City’s peak discharge requirements for the 1-, 2-, 10-, and 100-
year storm events.
Resubmittal Response: The September 4 stormwater memorandum includes
existing and proposed HydroCAD results for all four storm events. Proposed peak
flows are 1.75, 2.03, 4.05, and 8.00 cfs, compared with existing flows of 1.88, 2.34,
4.37, and 8.03 cfs.
Status: Addressed. The submitted calculations demonstrate proposed peak
discharge rates at or below existing conditions.
2. Original Comment: Provide existing and proposed impervious-area totals and
identify the net increase in impervious area used in the stormwater analysis.
Resubmittal Response: The HydroCAD and WinSLAMM materials provide drainage-
area and surface-area inputs, including 1.445 acres modeled for peak flow and
1.306 disturbed acres modeled for TSS.
Status: Addressed. The provided information shows the inputs and the stormwater
analysis shows the required rate and TSS control.
3. Original Comment: Clarify how the synthetic turf and playground surfacing are
modeled and provide construction and drainage details for these areas.
Resubmittal Response: Synthetic turf is now modeled as impervious, and the
Page 41 of 161
architectural exhibit identifies the turf locations. Final surfacing sections and
complete drainage details were not provided.
Status: Adressed. The calculations now consider the imperviousness of the
synthetic turf.
4. Original Comment: Submit complete HydroCAD and WinSLAMM calculations and
the native electronic model files for review.
Resubmittal Response: The resubmittal includes expanded HydroCAD and
WinSLAMM input and output reports and documents 63.46% TSS reduction. Native
electronic model files were not included.
Status: Partially addressed. Submit the native electronic HydroCAD and WinSLAMM
model files.
5. Original Comment: Provide a storm sewer drainage map, drainage areas, pipe
sizing, and inlet-capacity calculations for the proposed collection system.
Resubmittal Response: A storm sewer drainage map and revised sizing worksheet
are provided, including drainage areas and 10- and 100-year pipe-capacity checks.
Supporting inlet-capacity and bypass calculations were not provided.
Status: Partially addressed. Provide inlet-capacity calculations for each proposed
inlet or catch basin and identify the contributing area, design flow, bypass flow, and
downstream routing for each structure.
6. Original Comment: Identify and document the emergency overflow route for the
100-year storm event, including elevations, freeboard, and protection of buildings
and adjoining properties.
Resubmittal Response: The plans show proposed drainage patterns and the
underground detention system, but the emergency overflow route is not clearly
labeled or profiled.
Status: Partially addressed. Identify and profile the 100-year emergency overflow
route, provide controlling elevations and freeboard, and confirm that overflow will
not enter buildings or adversely affect adjacent properties or public rights-of-way.
7. Original Comment: Evaluate the effect of filling the existing depressional area and
verify that the downstream public storm sewer has adequate capacity for the
proposed discharge.
Resubmittal Response: The proposed peak discharge rates are controlled to
existing rates, but the submittal does not fully document displaced depressional
storage, overflow elevations, or downstream system capacity and tailwater
conditions.
Status: Partially addressed. Provide an existing-versus-proposed storage
comparison for the depression, document displaced storage and overflow
Page 42 of 161
elevations, and provide downstream capacity or tailwater verification for the
proposed connection.
8. Original Comment: Provide a stormwater operation and maintenance plan and, if
required by the City, a recordable maintenance agreement identifying inspection,
maintenance, documentation, and responsible-party requirements.
Resubmittal Response: An operation and maintenance plan is included. The plan
references the “City of Mequon,” contains differing inspection frequencies, and
does not clearly identify the responsible owner/contact or include an inspection
log.
Status: Partially addressed. Replace “City of Mequon” with “City of Fort Atkinson,”
reconcile the semiannual system inspection with the three-month isolator-row
inspection, identify the responsible owner/contact, provide an inspection and
maintenance log, and submit a recordable agreement if required.
9. NEW Comment: Show the actual type and layout of the proposed stormwater
management system on the erosion control plan and provide inlet protection at all
proposed inlets.
Site Plan / Transportation
10. Original Comment: Revise and document the Clarence Street driveway
configuration, including apron geometry, grades, right-of-way tie-ins, and
applicable City details.
Resubmittal Response: The driveway configuration has been revised and proposed
pavement geometry is shown. Final confirmation of apron limits, grades, existing
roadway tie-ins, and the City-standard detail remains outstanding.
Status: Partially addressed. Confirm that apron limits and grades match existing
roadway and right-of-way conditions and provide the applicable City-standard
driveway/apron detail.
11. Original Comment: Clarify internal vehicle circulation, address dead-end parking
and opposing movements, provide design-vehicle turning movements, and identify
signage, pavement markings, and snow-storage locations.
Resubmittal Response: The revised plans clarify parking, drive aisles, gates, and
drop-off circulation; however, dead-end parking areas and potential opposing
movements remain, and turning exhibits and snow-storage areas are not shown.
Status: Partially addressed. Provide turning-movement exhibits for the design
vehicle, add directional pavement markings and signs as appropriate, and identify
snow-storage areas that do not obstruct parking, accessible routes, drainage, or
sight lines.
Page 43 of 161
12. Original Comment: Reconcile proposed building and site elevations with existing
topography and coordinate finished-floor elevations between the civil and
architectural plans.
Resubmittal Response: The revised civil plans use elevations consistent with the
site topography.
Status: Addressed.
Accessibility
14. Original Comment: Provide complete accessible-route information from accessible
parking spaces to building entrances and recreation areas, including widths,
running slopes, cross slopes, spot grades, and curb-ramp details.
Resubmittal Response: Accessible parking and route alignments are shown, but
sufficient grading, slope, width, and curb-ramp information is not provided to verify
compliance.
Status: Partially addressed. Add complete accessible-route design information
from the accessible stalls to each building entrance and recreation area.
15. Original Comment: Provide a clear accessible pedestrian connection from the
western parking area to the buildings and recreation area and coordinate the
connection between the civil and architectural plans.
Resubmittal Response: The architectural site plan shows internal walkways, but the
civil plans do not clearly demonstrate or dimension an accessible connection from
the western parking area.
Status: Partially addressed. Add and dimension the accessible pedestrian
connection and coordinate it across the civil and architectural plan sets.
16. Original Comment: Provide sidewalk along the Jefferson Street frontage, including
grades, curb ramps, and connections to the on-site accessible route, or document
City approval of an alternate treatment or waiver.
Resubmittal Response: A Jefferson Street frontage sidewalk or documentation of an
approved alternate treatment or waiver was not provided.
Status: Not addressed. Provide the sidewalk and associated accessibility details, or
submit documentation of City approval for an alternate treatment or waiver.
Utilities
16. Original Comment: Obtain applicable City permits for work in the public right-of-
way and clearly distinguish public and private improvements, restoration limits, and
applicable City-standard details.
Resubmittal Response: The revised plans show utility and site work, but permit
status, public/private limits, restoration limits, and all applicable City-standard
Page 44 of 161
details are not fully documented.
Status: Open. Obtain the required permits and provide the outstanding limits and
details on the final plans.
General
21. Original Comment: Submit a written response to each review comment, highlight all
plan changes, and provide revised plans and supporting calculations for final
review.
Resubmittal Response: Revised civil plans and stormwater materials were
submitted and reviewed; several comments remain open or partially addressed.
Status: Partially addressed. Provide a response letter and revised final plan set
addressing each remaining comment. Highlight all changes and include revised
supporting calculations and native stormwater model files. Additional comments
may be generated upon review of the next resubmittal.
Page 45 of 161
pse
PARISH SURVEY & ENGINEERING
122 Wisconsin St ♦ West Bend, Wisconsin 53095
Phone (262) 346-7800 ♦ www.parishse.com
To: City of Fort Atkinson
Attn: Zach Navin
101 N Main Street
Fort Atkinson, WI 53538
From: Parish Survey & Engineering
Attn: Kevin Parish, PE
122 Wisconsin Street
West Bend, WI 53095
Re: Opportunities Inc. Recreation Area
Stormwater Management
815 Jefferson St, Fort Atkinson, 53538
Date: September 4, 2026
This memorandum summarizes the management of run-off from the proposed Recreation and
parking area, located at 815 Jefferson St. in the City of Fort Atkinson. The following information
is included to provide further details related to the run-off and sizing calculations:
Attachment A – Existing Conditions Drainage Map & HydroCAD Calculations
Attachment B – Proposed Conditions Drainage Map & HydroCAD Calculations
Attachment C – TSS Reduction Calculations
Attachment D – Storm Sewer Sizing Calculations
Attachment E – Stormwater Maintenance Plan
Design Standards
The proposed project will be subject to the City of Fort Atkinson’s stormwater requirements
found in Chapter 18, Article V of the Code of Ordinances.
Peak Discharge
Due to the increase in impervious area, the City of Fort Atkinson is requesting that proposed
peak flow rates for the 2, 10 and 100-year events match the existing peak flow rates. Since the
site will also disturb more than 1 acre, the site will also match the peak flow rate for the 1-year
event to comply with DNR requirements.
Total Suspended Solids (TSS)
This project is classified as a redevelopment since the proposed project will replace existing
development. Per Chapter 18, Article V, the site is to reduce the total suspended solids load by
40 percent for redevelopment.
Infiltration
The site is a redevelopment and is therefore exempt from infiltration requirements
Page 46 of 161
pse
PARISH SURVEY & ENGINEERING
Proposed Conditions
An ADS Underground Detention System will be used to manage the majority of the site. There is
some uncontrolled runoff to the existing storm sewer system on the property, as well as some
runoff to Jefferson Street and Clarence Street.
Summary of Results
Peak Discharge
Below is a table summarizing the peak flow rates for the overall site:
Table 1: Water Quantity Results
Storm Event
Existing Peak Flow
Rate
(cfs)
Proposed Peak
Flow Rate
(cfs)
1-Year 1.88 1.75
2-Year 2.34 2.03
10-Year 4.37 4.05
100-Year 8.03 8.00
Calculations can be found for the existing conditions in Attachment A and the calculations for
the proposed conditions can be found in Attachment B.
Total Suspended Solids (TSS)
Below is a summary of the TSS reduction calculations for the site:
Table 2: TSS Reduction Summary
Area Total Influent Load
(lbs)
Total Effluent Load
(lbs)
TSS Reduction
Site Disturbed Total
(1.306 acres) 619.6 226.4 63.46%
Calculations for TSS reduction can be found in Attachment C.
Conclusion
The site meets the 40% TSS reduction requirement. The Storm sewer was designed to handle
the 10-year storm and is shown in attachment E.
If there are any questions or if additional information is needed, please contact me via email at
kparish@parishse.com or by phone at (262) 346-7800.
Respectfully Submitted
K e v i n P a r i s h , P . E . F N : S R - 6 5 - 2 6
Page 47 of 161
9/4/2026
SWM-1
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
SWM REPORTOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
EXISTINGDRAINAGEMAPJDRLJKKJP
Page 48 of 161
Existing Conditions
Table of ContentsOpportunities Inc
Printed 9/4/2026Prepared by PSE
HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
TABLE OF CONTENTS
Project Reports
1 Routing Diagram
2 Rainfall Events Listing
1-Year Event
3 Subcat E1: To 6" Culvert
4 Subcat E1a: To Internal Kettle
5 Subcat E2: To Jefferson St
6 Subcat E3: To Clarence St
7 Pond 1P: Internal Kettle
9 Link E: Existing Total
2-Year Event
10 Subcat E1: To 6" Culvert
11 Subcat E1a: To Internal Kettle
12 Subcat E2: To Jefferson St
13 Subcat E3: To Clarence St
14 Pond 1P: Internal Kettle
16 Link E: Existing Total
10-Year Event
17 Subcat E1: To 6" Culvert
18 Subcat E1a: To Internal Kettle
19 Subcat E2: To Jefferson St
20 Subcat E3: To Clarence St
21 Pond 1P: Internal Kettle
23 Link E: Existing Total
100-Year Event
24 Subcat E1: To 6" Culvert
25 Subcat E1a: To Internal Kettle
26 Subcat E2: To Jefferson St
27 Subcat E3: To Clarence St
28 Pond 1P: Internal Kettle
30 Link E: Existing Total
Multi-Event Tables
31 Subcat E1: To 6" Culvert
32 Subcat E1a: To Internal Kettle
33 Subcat E2: To Jefferson St
34 Subcat E3: To Clarence St
35 Pond 1P: Internal Kettle
36 Link E: Existing Total
Page 49 of 161
E1
To 6" Culvert
E1a
To Internal Kettle
E2
To Jefferson St
E3
To Clarence St
1P
Internal Kettle
E
Existing Total
Routing Diagram for Opportunities Inc
Prepared by PSE, Printed 9/4/2026
HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Subcat Reach Pond Link
Page 50 of 161
Existing Conditions
Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 2HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Rainfall Events Listing
Event# Event
Name
Storm Type Curve Mode Duration
(hours)
B/B Depth
(inches)
AMC
1 1-Year MSE 24-hr 3 Default 24.00 1 2.46 2
2 2-Year MSE 24-hr 3 Default 24.00 1 2.79 2
3 10-Year MSE 24-hr 3 Default 24.00 1 3.93 2
4 100-Year MSE 24-hr 3 Default 24.00 1 6.19 2
Page 51 of 161
Existing Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 3HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E1: To 6" Culvert
Runoff = 1.21 cfs @ 12.23 hrs, Volume= 0.072 af, Depth> 1.15"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 1-Year Rainfall=2.46"
Area (ac) CN Description
* 0.048 98 Existing Roof
* 0.257 98 Existing Asphalt/Concrete
* 0.081 96 Existing Gravel
0.366 74 >75% Grass cover, Good, HSG C
0.752 86 Weighted Average
0.447 59.44% Pervious Area
0.305 40.56% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
13.3 100 0.0110 0.13 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
0.6 59 0.0136 1.75 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
13.9 159 Total
Subcatchment E1: To 6" Culvert
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
MSE 24-hr 3
1-Year Rainfall=2.46"
Runoff Area=0.752 ac
Runoff Volume=0.072 af
Runoff Depth>1.15"
Flow Length=159'
Tc=13.9 min
CN=86
1.21 cfs
Page 52 of 161
Existing Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 4HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E1a: To Internal Kettle
Runoff = 0.17 cfs @ 12.15 hrs, Volume= 0.008 af, Depth> 0.55"
Routed to Pond 1P : Internal Kettle
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 1-Year Rainfall=2.46"
Area (ac) CN Description
0.179 74 >75% Grass cover, Good, HSG C
0.179 100.00% Pervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
7.0 57 0.0175 0.13 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E1a: To Internal Kettle
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.19
0.18
0.17
0.16
0.15
0.14
0.13
0.12
0.11
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
MSE 24-hr 3
1-Year Rainfall=2.46"
Runoff Area=0.179 ac
Runoff Volume=0.008 af
Runoff Depth>0.55"
Flow Length=57'
Slope=0.0175 '/'
Tc=7.0 min
CN=74
0.17 cfs
Page 53 of 161
Existing Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 5HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E2: To Jefferson St
Runoff = 0.60 cfs @ 12.15 hrs, Volume= 0.029 af, Depth> 1.51"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 1-Year Rainfall=2.46"
Area (ac) CN Description
* 0.045 98 Existing Roof
* 0.122 98 Existing Asphalt/Concrete
0.063 74 >75% Grass cover, Good, HSG C
0.230 91 Weighted Average
0.063 27.39% Pervious Area
0.167 72.61% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
7.6 75 0.0255 0.17 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E2: To Jefferson St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
MSE 24-hr 3
1-Year Rainfall=2.46"
Runoff Area=0.230 ac
Runoff Volume=0.029 af
Runoff Depth>1.51"
Flow Length=75'
Slope=0.0255 '/'
Tc=7.6 min
CN=91
0.60 cfs
Page 54 of 161
Existing Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 6HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E3: To Clarence St
Runoff = 0.22 cfs @ 12.24 hrs, Volume= 0.014 af, Depth> 0.59"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 1-Year Rainfall=2.46"
Area (ac) CN Description
* 0.010 98 Existing Roof
* 0.007 96 Existing Gravel
0.267 74 >75% Grass cover, Good, HSG C
0.284 75 Weighted Average
0.274 96.48% Pervious Area
0.010 3.52% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
13.4 96 0.0100 0.12 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E3: To Clarence St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.24
0.23
0.22
0.21
0.2
0.19
0.18
0.17
0.16
0.15
0.14
0.13
0.12
0.11
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
MSE 24-hr 3
1-Year Rainfall=2.46"
Runoff Area=0.284 ac
Runoff Volume=0.014 af
Runoff Depth>0.59"
Flow Length=96'
Slope=0.0100 '/'
Tc=13.4 min
CN=75
0.22 cfs
Page 55 of 161
Existing Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 7HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Pond 1P: Internal Kettle
Inflow Area = 0.179 ac, 0.00% Impervious, Inflow Depth > 0.55" for 1-Year event
Inflow = 0.17 cfs @ 12.15 hrs, Volume= 0.008 af
Outflow = 0.05 cfs @ 12.46 hrs, Volume= 0.005 af, Atten= 72%, L ag= 18.5 min
Primary = 0.05 cfs @ 12.46 hrs, Volume= 0.005 af
Routed to Link E : Existing Total
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 787.47' @ 12.46 hrs Surf.Area= 569 sf Storage= 145 cf
Plug-Flow detention time= 125.1 min calculated for 0.005 af (63% of inflow)
Center-of-Mass det. time= 54.1 min ( 867.2 - 813.1 )
Volume Invert Avail.Storage Storage Description
#1 787.04' 171 cf Custom Stage Data (Prismatic) Listed below
Elevation Surf.Area Inc.Store Cum.Store
(feet) (sq-ft) (cubic-feet) (cubic-feet)
787.04 1 0 0
787.55 670 171 171
Device Routing Invert Outlet Devices
#1 Primary 787.42' 1.0' long + 10.0 '/' SideZ x 1.0' breadth Broad-Crested Rectangular Weir
Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00
2.50 3.00
Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31
3.30 3.31 3.32
Primary OutFlow Max=0.05 cfs @ 12.46 hrs HW=787.47' (Free Discharge)
1=Broad-Crested Rectangular Weir (Weir Controls 0.05 cfs @ 0.57 fps)
Page 56 of 161
Existing Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 8HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond 1P: Internal Kettle
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.19
0.18
0.17
0.16
0.15
0.14
0.13
0.12
0.11
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
Inflow Area=0.179 ac
Peak Elev=787.47'
Storage=145 cf
0.17 cfs
0.05 cfs
Page 57 of 161
Existing Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 9HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Link E: Existing Total
Inflow Area = 1.445 ac, 33.36% Impervious, Inflow Depth > 1.00" for 1-Year event
Inflow = 1.88 cfs @ 12.20 hrs, Volume= 0.120 af
Primary = 1.88 cfs @ 12.20 hrs, Volume= 0.120 af, Atten= 0%, La g= 0.0 min
Primary outflow = Inflow, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Link E: Existing Total
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
2
1
0
Inflow Area=1.445 ac
1.88 cfs
1.88 cfs
Page 58 of 161
Existing Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 10HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E1: To 6" Culvert
Runoff = 1.49 cfs @ 12.22 hrs, Volume= 0.089 af, Depth> 1.42"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 2-Year Rainfall=2.79"
Area (ac) CN Description
* 0.048 98 Existing Roof
* 0.257 98 Existing Asphalt/Concrete
* 0.081 96 Existing Gravel
0.366 74 >75% Grass cover, Good, HSG C
0.752 86 Weighted Average
0.447 59.44% Pervious Area
0.305 40.56% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
13.3 100 0.0110 0.13 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
0.6 59 0.0136 1.75 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
13.9 159 Total
Subcatchment E1: To 6" Culvert
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
MSE 24-hr 3
2-Year Rainfall=2.79"
Runoff Area=0.752 ac
Runoff Volume=0.089 af
Runoff Depth>1.42"
Flow Length=159'
Tc=13.9 min
CN=86
1.49 cfs
Page 59 of 161
Existing Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 11HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E1a: To Internal Kettle
Runoff = 0.23 cfs @ 12.15 hrs, Volume= 0.011 af, Depth> 0.73"
Routed to Pond 1P : Internal Kettle
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 2-Year Rainfall=2.79"
Area (ac) CN Description
0.179 74 >75% Grass cover, Good, HSG C
0.179 100.00% Pervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
7.0 57 0.0175 0.13 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E1a: To Internal Kettle
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.26
0.25
0.24
0.23
0.22
0.21
0.2
0.19
0.18
0.17
0.16
0.15
0.14
0.13
0.12
0.11
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
MSE 24-hr 3
2-Year Rainfall=2.79"
Runoff Area=0.179 ac
Runoff Volume=0.011 af
Runoff Depth>0.73"
Flow Length=57'
Slope=0.0175 '/'
Tc=7.0 min
CN=74
0.23 cfs
Page 60 of 161
Existing Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 12HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E2: To Jefferson St
Runoff = 0.71 cfs @ 12.15 hrs, Volume= 0.035 af, Depth> 1.81"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 2-Year Rainfall=2.79"
Area (ac) CN Description
* 0.045 98 Existing Roof
* 0.122 98 Existing Asphalt/Concrete
0.063 74 >75% Grass cover, Good, HSG C
0.230 91 Weighted Average
0.063 27.39% Pervious Area
0.167 72.61% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
7.6 75 0.0255 0.17 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E2: To Jefferson St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.75
0.7
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
MSE 24-hr 3
2-Year Rainfall=2.79"
Runoff Area=0.230 ac
Runoff Volume=0.035 af
Runoff Depth>1.81"
Flow Length=75'
Slope=0.0255 '/'
Tc=7.6 min
CN=91
0.71 cfs
Page 61 of 161
Existing Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 13HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E3: To Clarence St
Runoff = 0.30 cfs @ 12.23 hrs, Volume= 0.018 af, Depth> 0.78"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 2-Year Rainfall=2.79"
Area (ac) CN Description
* 0.010 98 Existing Roof
* 0.007 96 Existing Gravel
0.267 74 >75% Grass cover, Good, HSG C
0.284 75 Weighted Average
0.274 96.48% Pervious Area
0.010 3.52% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
13.4 96 0.0100 0.12 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E3: To Clarence St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.32
0.3
0.28
0.26
0.24
0.22
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
MSE 24-hr 3
2-Year Rainfall=2.79"
Runoff Area=0.284 ac
Runoff Volume=0.018 af
Runoff Depth>0.78"
Flow Length=96'
Slope=0.0100 '/'
Tc=13.4 min
CN=75
0.30 cfs
Page 62 of 161
Existing Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 14HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Pond 1P: Internal Kettle
Inflow Area = 0.179 ac, 0.00% Impervious, Inflow Depth > 0.73" for 2-Year event
Inflow = 0.23 cfs @ 12.15 hrs, Volume= 0.011 af
Outflow = 0.11 cfs @ 12.30 hrs, Volume= 0.008 af, Atten= 52%, L ag= 8.7 min
Primary = 0.11 cfs @ 12.30 hrs, Volume= 0.008 af
Routed to Link E : Existing Total
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 787.51' @ 12.30 hrs Surf.Area= 611 sf Storage= 156 cf
Plug-Flow detention time= 97.1 min calculated for 0.008 af (72% of inflow)
Center-of-Mass det. time= 36.2 min ( 843.7 - 807.6 )
Volume Invert Avail.Storage Storage Description
#1 787.04' 171 cf Custom Stage Data (Prismatic) Listed below
Elevation Surf.Area Inc.Store Cum.Store
(feet) (sq-ft) (cubic-feet) (cubic-feet)
787.04 1 0 0
787.55 670 171 171
Device Routing Invert Outlet Devices
#1 Primary 787.42' 1.0' long + 10.0 '/' SideZ x 1.0' breadth Broad-Crested Rectangular Weir
Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00
2.50 3.00
Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31
3.30 3.31 3.32
Primary OutFlow Max=0.11 cfs @ 12.30 hrs HW=787.50' (Free Discharge)
1=Broad-Crested Rectangular Weir (Weir Controls 0.11 cfs @ 0.71 fps)
Page 63 of 161
Existing Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 15HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond 1P: Internal Kettle
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.26
0.24
0.22
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
Inflow Area=0.179 ac
Peak Elev=787.51'
Storage=156 cf
0.23 cfs
0.11 cfs
Page 64 of 161
Existing Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 16HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Link E: Existing Total
Inflow Area = 1.445 ac, 33.36% Impervious, Inflow Depth > 1.24" for 2-Year event
Inflow = 2.34 cfs @ 12.21 hrs, Volume= 0.150 af
Primary = 2.34 cfs @ 12.21 hrs, Volume= 0.150 af, Atten= 0%, La g= 0.0 min
Primary outflow = Inflow, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Link E: Existing Total
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
2
1
0
Inflow Area=1.445 ac
2.34 cfs
2.34 cfs
Page 65 of 161
Existing Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 17HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E1: To 6" Culvert
Runoff = 2.47 cfs @ 12.22 hrs, Volume= 0.149 af, Depth> 2.38"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 10-Year Rainfall=3.93"
Area (ac) CN Description
* 0.048 98 Existing Roof
* 0.257 98 Existing Asphalt/Concrete
* 0.081 96 Existing Gravel
0.366 74 >75% Grass cover, Good, HSG C
0.752 86 Weighted Average
0.447 59.44% Pervious Area
0.305 40.56% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
13.3 100 0.0110 0.13 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
0.6 59 0.0136 1.75 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
13.9 159 Total
Subcatchment E1: To 6" Culvert
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
2
1
0
MSE 24-hr 3
10-Year Rainfall=3.93"
Runoff Area=0.752 ac
Runoff Volume=0.149 af
Runoff Depth>2.38"
Flow Length=159'
Tc=13.9 min
CN=86
2.47 cfs
Page 66 of 161
Existing Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 18HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E1a: To Internal Kettle
Runoff = 0.48 cfs @ 12.15 hrs, Volume= 0.022 af, Depth> 1.47"
Routed to Pond 1P : Internal Kettle
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 10-Year Rainfall=3.93"
Area (ac) CN Description
0.179 74 >75% Grass cover, Good, HSG C
0.179 100.00% Pervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
7.0 57 0.0175 0.13 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E1a: To Internal Kettle
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
MSE 24-hr 3
10-Year Rainfall=3.93"
Runoff Area=0.179 ac
Runoff Volume=0.022 af
Runoff Depth>1.47"
Flow Length=57'
Slope=0.0175 '/'
Tc=7.0 min
CN=74
0.48 cfs
Page 67 of 161
Existing Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 19HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E2: To Jefferson St
Runoff = 1.09 cfs @ 12.15 hrs, Volume= 0.055 af, Depth> 2.85"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 10-Year Rainfall=3.93"
Area (ac) CN Description
* 0.045 98 Existing Roof
* 0.122 98 Existing Asphalt/Concrete
0.063 74 >75% Grass cover, Good, HSG C
0.230 91 Weighted Average
0.063 27.39% Pervious Area
0.167 72.61% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
7.6 75 0.0255 0.17 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E2: To Jefferson St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
MSE 24-hr 3
10-Year Rainfall=3.93"
Runoff Area=0.230 ac
Runoff Volume=0.055 af
Runoff Depth>2.85"
Flow Length=75'
Slope=0.0255 '/'
Tc=7.6 min
CN=91
1.09 cfs
Page 68 of 161
Existing Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 20HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E3: To Clarence St
Runoff = 0.62 cfs @ 12.22 hrs, Volume= 0.036 af, Depth> 1.53"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 10-Year Rainfall=3.93"
Area (ac) CN Description
* 0.010 98 Existing Roof
* 0.007 96 Existing Gravel
0.267 74 >75% Grass cover, Good, HSG C
0.284 75 Weighted Average
0.274 96.48% Pervious Area
0.010 3.52% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
13.4 96 0.0100 0.12 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E3: To Clarence St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
MSE 24-hr 3
10-Year Rainfall=3.93"
Runoff Area=0.284 ac
Runoff Volume=0.036 af
Runoff Depth>1.53"
Flow Length=96'
Slope=0.0100 '/'
Tc=13.4 min
CN=75
0.62 cfs
Page 69 of 161
Existing Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 21HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Pond 1P: Internal Kettle
[93] Warning: Storage range exceeded by 0.07'
[88] Warning: Qout>Qin may require smaller dt or Finer Routing
Inflow Area = 0.179 ac, 0.00% Impervious, Inflow Depth > 1.47" for 10-Year event
Inflow = 0.48 cfs @ 12.15 hrs, Volume= 0.022 af
Outflow = 0.61 cfs @ 12.15 hrs, Volume= 0.019 af, Atten= 0%, La g= 0.2 min
Primary = 0.61 cfs @ 12.15 hrs, Volume= 0.019 af
Routed to Link E : Existing Total
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 787.62' @ 12.15 hrs Surf.Area= 670 sf Storage= 171 cf
Plug-Flow detention time= 56.5 min calculated for 0.019 af (86% of inflow)
Center-of-Mass det. time= 16.5 min ( 811.9 - 795.4 )
Volume Invert Avail.Storage Storage Description
#1 787.04' 171 cf Custom Stage Data (Prismatic) Listed below
Elevation Surf.Area Inc.Store Cum.Store
(feet) (sq-ft) (cubic-feet) (cubic-feet)
787.04 1 0 0
787.55 670 171 171
Device Routing Invert Outlet Devices
#1 Primary 787.42' 1.0' long + 10.0 '/' SideZ x 1.0' breadth Broad-Crested Rectangular Weir
Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00
2.50 3.00
Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31
3.30 3.31 3.32
Primary OutFlow Max=0.61 cfs @ 12.15 hrs HW=787.62' (Free Discharge)
1=Broad-Crested Rectangular Weir (Weir Controls 0.61 cfs @ 1.04 fps)
Page 70 of 161
Existing Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 22HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond 1P: Internal Kettle
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Inflow Area=0.179 ac
Peak Elev=787.62'
Storage=171 cf
0.48 cfs
0.61 cfs
Page 71 of 161
Existing Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 23HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Link E: Existing Total
Inflow Area = 1.445 ac, 33.36% Impervious, Inflow Depth > 2.15" for 10-Year event
Inflow = 4.37 cfs @ 12.17 hrs, Volume= 0.259 af
Primary = 4.37 cfs @ 12.17 hrs, Volume= 0.259 af, Atten= 0%, La g= 0.0 min
Primary outflow = Inflow, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Link E: Existing Total
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
4
3
2
1
0
Inflow Area=1.445 ac
4.37 cfs
4.37 cfs
Page 72 of 161
Existing Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 24HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E1: To 6" Culvert
Runoff = 4.46 cfs @ 12.22 hrs, Volume= 0.277 af, Depth> 4.42"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 100-Year Rainfall=6.19"
Area (ac) CN Description
* 0.048 98 Existing Roof
* 0.257 98 Existing Asphalt/Concrete
* 0.081 96 Existing Gravel
0.366 74 >75% Grass cover, Good, HSG C
0.752 86 Weighted Average
0.447 59.44% Pervious Area
0.305 40.56% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
13.3 100 0.0110 0.13 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
0.6 59 0.0136 1.75 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
13.9 159 Total
Subcatchment E1: To 6" Culvert
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
4
3
2
1
0
MSE 24-hr 3
100-Year Rainfall=6.19"
Runoff Area=0.752 ac
Runoff Volume=0.277 af
Runoff Depth>4.42"
Flow Length=159'
Tc=13.9 min
CN=86
4.46 cfs
Page 73 of 161
Existing Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 25HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E1a: To Internal Kettle
Runoff = 1.04 cfs @ 12.14 hrs, Volume= 0.048 af, Depth> 3.20"
Routed to Pond 1P : Internal Kettle
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 100-Year Rainfall=6.19"
Area (ac) CN Description
0.179 74 >75% Grass cover, Good, HSG C
0.179 100.00% Pervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
7.0 57 0.0175 0.13 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E1a: To Internal Kettle
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
MSE 24-hr 3
100-Year Rainfall=6.19"
Runoff Area=0.179 ac
Runoff Volume=0.048 af
Runoff Depth>3.20"
Flow Length=57'
Slope=0.0175 '/'
Tc=7.0 min
CN=74
1.04 cfs
Page 74 of 161
Existing Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 26HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E2: To Jefferson St
Runoff = 1.84 cfs @ 12.15 hrs, Volume= 0.095 af, Depth> 4.98"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 100-Year Rainfall=6.19"
Area (ac) CN Description
* 0.045 98 Existing Roof
* 0.122 98 Existing Asphalt/Concrete
0.063 74 >75% Grass cover, Good, HSG C
0.230 91 Weighted Average
0.063 27.39% Pervious Area
0.167 72.61% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
7.6 75 0.0255 0.17 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E2: To Jefferson St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
2
1
0
MSE 24-hr 3
100-Year Rainfall=6.19"
Runoff Area=0.230 ac
Runoff Volume=0.095 af
Runoff Depth>4.98"
Flow Length=75'
Slope=0.0255 '/'
Tc=7.6 min
CN=91
1.84 cfs
Page 75 of 161
Existing Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 27HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment E3: To Clarence St
Runoff = 1.33 cfs @ 12.22 hrs, Volume= 0.078 af, Depth> 3.30"
Routed to Link E : Existing Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 100-Year Rainfall=6.19"
Area (ac) CN Description
* 0.010 98 Existing Roof
* 0.007 96 Existing Gravel
0.267 74 >75% Grass cover, Good, HSG C
0.284 75 Weighted Average
0.274 96.48% Pervious Area
0.010 3.52% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
13.4 96 0.0100 0.12 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
Subcatchment E3: To Clarence St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
MSE 24-hr 3
100-Year Rainfall=6.19"
Runoff Area=0.284 ac
Runoff Volume=0.078 af
Runoff Depth>3.30"
Flow Length=96'
Slope=0.0100 '/'
Tc=13.4 min
CN=75
1.33 cfs
Page 76 of 161
Existing Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 28HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Pond 1P: Internal Kettle
[93] Warning: Storage range exceeded by 0.12'
Inflow Area = 0.179 ac, 0.00% Impervious, Inflow Depth > 3.20" for 100-Year event
Inflow = 1.04 cfs @ 12.14 hrs, Volume= 0.048 af
Outflow = 1.02 cfs @ 12.14 hrs, Volume= 0.045 af, Atten= 2%, La g= 0.0 min
Primary = 1.02 cfs @ 12.14 hrs, Volume= 0.045 af
Routed to Link E : Existing Total
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 787.67' @ 12.14 hrs Surf.Area= 670 sf Storage= 171 cf
Plug-Flow detention time= 31.2 min calculated for 0.045 af (93% of inflow)
Center-of-Mass det. time= 9.5 min ( 792.0 - 782.6 )
Volume Invert Avail.Storage Storage Description
#1 787.04' 171 cf Custom Stage Data (Prismatic) Listed below
Elevation Surf.Area Inc.Store Cum.Store
(feet) (sq-ft) (cubic-feet) (cubic-feet)
787.04 1 0 0
787.55 670 171 171
Device Routing Invert Outlet Devices
#1 Primary 787.42' 1.0' long + 10.0 '/' SideZ x 1.0' breadth Broad-Crested Rectangular Weir
Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00
2.50 3.00
Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31
3.30 3.31 3.32
Primary OutFlow Max=1.00 cfs @ 12.14 hrs HW=787.67' (Free Discharge)
1=Broad-Crested Rectangular Weir (Weir Controls 1.00 cfs @ 1.15 fps)
Page 77 of 161
Existing Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 29HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond 1P: Internal Kettle
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
Inflow Area=0.179 ac
Peak Elev=787.67'
Storage=171 cf
1.04 cfs
1.02 cfs
Page 78 of 161
Existing Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 30HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Link E: Existing Total
Inflow Area = 1.445 ac, 33.36% Impervious, Inflow Depth > 4.11" for 100-Year event
Inflow = 8.03 cfs @ 12.19 hrs, Volume= 0.495 af
Primary = 8.03 cfs @ 12.19 hrs, Volume= 0.495 af, Atten= 0%, La g= 0.0 min
Primary outflow = Inflow, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Link E: Existing Total
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
8
7
6
5
4
3
2
1
0
Inflow Area=1.445 ac
8.03 cfs
8.03 cfs
Page 79 of 161
Existing Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 31HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Subcatchment E1: To 6" Culvert
Event Rainfall
(inches)
Runoff
(cfs)
Volume
(acre-feet)
1-Year 2.46 1.21 0.072
2-Year 2.79 1.49 0.089
10-Year 3.93 2.47 0.149
100-Year 6.19 4.46 0.277
Page 80 of 161
Existing Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 32HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Subcatchment E1a: To Internal Kettle
Event Rainfall
(inches)
Runoff
(cfs)
Volume
(acre-feet)
1-Year 2.46 0.17 0.008
2-Year 2.79 0.23 0.011
10-Year 3.93 0.48 0.022
100-Year 6.19 1.04 0.048
Page 81 of 161
Existing Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 33HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Subcatchment E2: To Jefferson St
Event Rainfall
(inches)
Runoff
(cfs)
Volume
(acre-feet)
1-Year 2.46 0.60 0.029
2-Year 2.79 0.71 0.035
10-Year 3.93 1.09 0.055
100-Year 6.19 1.84 0.095
Page 82 of 161
Existing Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 34HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Subcatchment E3: To Clarence St
Event Rainfall
(inches)
Runoff
(cfs)
Volume
(acre-feet)
1-Year 2.46 0.22 0.014
2-Year 2.79 0.30 0.018
10-Year 3.93 0.62 0.036
100-Year 6.19 1.33 0.078
Page 83 of 161
Existing Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 35HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Pond 1P: Internal Kettle
Event Inflow
(cfs)
Primary
(cfs)
Elevation
(feet)
Storage
(cubic-feet)
1-Year 0.17 0.05 787.47 145
2-Year 0.23 0.11 787.51 156
10-Year 0.48 0.61 787.62 171
100-Year 1.04 1.02 787.67 171
Page 84 of 161
Existing Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 36HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Link E: Existing Total
Event Inflow
(cfs)
Primary
(cfs)
Volume
(acre-feet)
1-Year 1.88 1.88 0.120
2-Year 2.34 2.34 0.150
10-Year 4.37 4.37 0.259
100-Year 8.03 8.03 0.495
Page 85 of 161
NORTH 72°25'55" WEST 251.05'
NORTH 17°32'36" EAST 485.86'
SOUTH 22°14'26" WEST 511.67'
9/4/2026
SWM-2
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
SWM REPORTOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
PROPOSEDDRAINAGEMAPEJQLJKKJP
Page 86 of 161
P1
To 6" Culvert
P1a
To Underground
Detention
P2
To Jefferson StP3
To Clarence St
UD
Underground Detention
P
Proposed Total
Routing Diagram for Opportunities Inc
Prepared by PSE, Printed 9/4/2026
HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Subcat Reach Pond Link
Page 87 of 161
Proposed Conditions
Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 2HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Rainfall Events Listing
Event# Event
Name
Storm Type Curve Mode Duration
(hours)
B/B Depth
(inches)
AMC
1 1-Year MSE 24-hr 3 Default 24.00 1 2.46 2
2 2-Year MSE 24-hr 3 Default 24.00 1 2.79 2
3 10-Year MSE 24-hr 3 Default 24.00 1 3.93 2
4 100-Year MSE 24-hr 3 Default 24.00 1 6.19 2
Page 88 of 161
Proposed Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 3HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P1: To 6" Culvert
Runoff = 0.44 cfs @ 12.19 hrs, Volume= 0.024 af, Depth> 1.22"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 1-Year Rainfall=2.46"
Area (ac) CN Description
* 0.008 98 Proposed Sidewalk
* 0.122 98 Existing Asphalt/Concrete
0.104 74 >75% Grass cover, Good, HSG C
0.234 87 Weighted Average
0.104 44.44% Pervious Area
0.130 55.56% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
9.4 92 0.0220 0.16 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
1.4 135 0.0113 1.59 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
10.8 227 Total
Subcatchment P1: To 6" Culvert
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.48
0.46
0.44
0.42
0.4
0.38
0.36
0.34
0.32
0.3
0.28
0.26
0.24
0.22
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
MSE 24-hr 3
1-Year Rainfall=2.46"
Runoff Area=0.234 ac
Runoff Volume=0.024 af
Runoff Depth>1.22"
Flow Length=227'
Tc=10.8 min
CN=87
0.44 cfs
Page 89 of 161
Proposed Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 4HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P1a: To Underground Detention
Runoff = 3.26 cfs @ 12.13 hrs, Volume= 0.168 af, Depth> 2.16"
Routed to Pond UD : Underground Detention
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 1-Year Rainfall=2.46"
Area (ac) CN Description
* 0.057 98 Existing Building
* 0.168 98 Proposed Concrete
* 0.400 98 Proposed parking lots
* 0.312 98 Proposed Artificial Turf
0.937 98 Weighted Average
0.937 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry,
Subcatchment P1a: To Underground Detention
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
3
2
1
0
MSE 24-hr 3
1-Year Rainfall=2.46"
Runoff Area=0.937 ac
Runoff Volume=0.168 af
Runoff Depth>2.16"
Tc=6.0 min
CN=98
3.26 cfs
Page 90 of 161
Proposed Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 5HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P2: To Jefferson St
Runoff = 0.43 cfs @ 12.13 hrs, Volume= 0.020 af, Depth> 1.36"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 1-Year Rainfall=2.46"
Area (ac) CN Description
* 0.045 98 Existing Roof
* 0.064 98 Proposed Asphalt/Concrete
0.063 74 >75% Grass cover, Good, HSG C
0.172 89 Weighted Average
0.063 36.63% Pervious Area
0.109 63.37% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry,
Subcatchment P2: To Jefferson St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.48
0.46
0.44
0.42
0.4
0.38
0.36
0.34
0.32
0.3
0.28
0.26
0.24
0.22
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
MSE 24-hr 3
1-Year Rainfall=2.46"
Runoff Area=0.172 ac
Runoff Volume=0.020 af
Runoff Depth>1.36"
Tc=6.0 min
CN=89
0.43 cfs
Page 91 of 161
Proposed Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 6HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P3: To Clarence St
Runoff = 0.07 cfs @ 12.26 hrs, Volume= 0.005 af, Depth> 0.59"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 1-Year Rainfall=2.46"
Area (ac) CN Description
* 0.006 98 Proposed Asphalt
0.096 74 >75% Grass cover, Good, HSG C
0.102 75 Weighted Average
0.096 94.12% Pervious Area
0.006 5.88% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
15.1 100 0.0080 0.11 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
0.3 25 0.0100 1.50 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
15.4 125 Total
Subcatchment P3: To Clarence St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.08
0.075
0.07
0.065
0.06
0.055
0.05
0.045
0.04
0.035
0.03
0.025
0.02
0.015
0.01
0.005
0
MSE 24-hr 3
1-Year Rainfall=2.46"
Runoff Area=0.102 ac
Runoff Volume=0.005 af
Runoff Depth>0.59"
Flow Length=125'
Tc=15.4 min
CN=75
0.07 cfs
Page 92 of 161
Proposed Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 7HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Pond UD: Underground Detention
[82] Warning: Early inflow requires earlier time span
Inflow Area = 0.937 ac,100.00% Impervious, Inflow Depth > 2.16" for 1-Year event
Inflow = 3.26 cfs @ 12.13 hrs, Volume= 0.168 af
Outflow = 0.96 cfs @ 12.31 hrs, Volume= 0.151 af, Atten= 70%, L ag= 11.0 min
Discarded = 0.00 cfs @ 12.31 hrs, Volume= 0.003 af
Primary = 0.96 cfs @ 12.31 hrs, Volume= 0.148 af
Routed to Link P : Proposed Total
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 784.72' @ 12.31 hrs Surf.Area= 0.059 ac Storage= 0.074 af
Plug-Flow detention time= 86.0 min calculated for 0.151 af (90% of inflow)
Center-of-Mass det. time= 56.0 min ( 798.0 - 742.0 )
Volume Invert Avail.Storage Storage Description
#1A 782.94' 0.054 af 42.25'W x 60.70'L x 3.75'H Field A
0.221 af Overall - 0.085 af Embedded = 0.136 af x 40.0% Voids
#2A 783.44' 0.085 af ADS_StormTech SC-800 +Cap x 72 Inside #1
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
72 Chambers in 9 Rows
Cap Storage= 3.4 cf x 2 x 9 rows = 61.6 cf
0.139 af Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 782.94' 0.040 in/hr Exfiltration over Surface area
Conductivity to Groundwater Elevation = 775.00'
#2 Primary 783.44' 12.0" Round 12" Outlet Pipe
L= 71.0' CPP, projecting, no headwall, Ke= 0.900
Inlet / Outlet Invert= 783.44' / 783.20' S= 0.0034 '/' Cc= 0.900
n= 0.012 Corrugated PP, smooth interior, Flow Area= 0.79 sf
#3 Device 2 783.44' 6.0" Vert. Orifice 1 C= 0.600 Limited to weir flow at low heads
#4 Device 2 785.00' 6.0" Vert. Orifice 2 X 3.00 C= 0.600
Limited to weir flow at low heads
#5 Device 2 786.25' 4.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s)
Discarded OutFlow Max=0.00 cfs @ 12.31 hrs HW=784.72' (Free Discharge)
1=Exfiltration ( Controls 0.00 cfs)
Primary OutFlow Max=0.96 cfs @ 12.31 hrs HW=784.72' (Free Discharge)
2=12" Outlet Pipe (Passes 0.96 cfs of 2.48 cfs potential flow)
3=Orifice 1 (Orifice Controls 0.96 cfs @ 4.89 fps)
4=Orifice 2 ( Controls 0.00 cfs)
5=Sharp-Crested Rectangular Weir ( Controls 0.00 cfs)
Page 93 of 161
Proposed Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 8HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond UD: Underground Detention - Chamber Wizard Field A
Chamber Model = ADS_StormTech SC-800 +Cap (ADS StormTech® SC-800 with cap volume)
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
Cap Storage= 3.4 cf x 2 x 9 rows = 61.6 cf
51.0" Wide + 3.0" Spacing = 54.0" C-C Row Spacing
8 Chambers/Row x 7.12' Long +0.88' Cap Length x 2 = 58.70' Row Length +12.0" End Stone x 2 = 60.70'
Base Length
9 Rows x 51.0" Wide + 3.0" Spacing x 8 + 12.0" Side Stone x 2 = 42.25' Base Width
6.0" Stone Base + 33.0" Chamber Height + 6.0" Stone Cover = 3.75' Field Height
72 Chambers x 50.6 cf + 3.4 cf Cap Volume x 2 x 9 Rows = 3,704.2 cf Chamber Storage
9,617.2 cf Field - 3,704.2 cf Chambers = 5,913.0 cf Stone x 40.0% Voids = 2,365.2 cf Stone Storage
Chamber Storage + Stone Storage = 6,069.4 cf = 0.139 af
Overall Storage Efficiency = 63.1%
Overall System Size = 60.70' x 42.25' x 3.75'
72 Chambers
356.2 cy Field
219.0 cy Stone
Page 94 of 161
Proposed Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 9HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond UD: Underground Detention
Inflow
Outflow
Discarded
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
3
2
1
0
Inflow Area=0.937 ac
Peak Elev=784.72'
Storage=0.074 af
3.26 cfs
0.96 cfs
0.00 cfs
0.96 cfs
Page 95 of 161
Proposed Conditions
MSE 24-hr 3 1-Year Rainfall=2.46"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 10HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Link P: Proposed Total
Inflow Area = 1.445 ac, 81.80% Impervious, Inflow Depth > 1.63" for 1-Year event
Inflow = 1.75 cfs @ 12.17 hrs, Volume= 0.197 af
Primary = 1.75 cfs @ 12.17 hrs, Volume= 0.197 af, Atten= 0%, La g= 0.0 min
Primary outflow = Inflow, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Link P: Proposed Total
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
Inflow Area=1.445 ac
1.75 cfs
1.75 cfs
Page 96 of 161
Proposed Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 11HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P1: To 6" Culvert
Runoff = 0.54 cfs @ 12.19 hrs, Volume= 0.029 af, Depth> 1.49"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 2-Year Rainfall=2.79"
Area (ac) CN Description
* 0.008 98 Proposed Sidewalk
* 0.122 98 Existing Asphalt/Concrete
0.104 74 >75% Grass cover, Good, HSG C
0.234 87 Weighted Average
0.104 44.44% Pervious Area
0.130 55.56% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
9.4 92 0.0220 0.16 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
1.4 135 0.0113 1.59 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
10.8 227 Total
Subcatchment P1: To 6" Culvert
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
MSE 24-hr 3
2-Year Rainfall=2.79"
Runoff Area=0.234 ac
Runoff Volume=0.029 af
Runoff Depth>1.49"
Flow Length=227'
Tc=10.8 min
CN=87
0.54 cfs
Page 97 of 161
Proposed Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 12HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P1a: To Underground Detention
Runoff = 3.71 cfs @ 12.13 hrs, Volume= 0.193 af, Depth> 2.47"
Routed to Pond UD : Underground Detention
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 2-Year Rainfall=2.79"
Area (ac) CN Description
* 0.057 98 Existing Building
* 0.168 98 Proposed Concrete
* 0.400 98 Proposed parking lots
* 0.312 98 Proposed Artificial Turf
0.937 98 Weighted Average
0.937 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry,
Subcatchment P1a: To Underground Detention
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
4
3
2
1
0
MSE 24-hr 3
2-Year Rainfall=2.79"
Runoff Area=0.937 ac
Runoff Volume=0.193 af
Runoff Depth>2.47"
Tc=6.0 min
CN=98
3.71 cfs
Page 98 of 161
Proposed Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 13HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P2: To Jefferson St
Runoff = 0.52 cfs @ 12.13 hrs, Volume= 0.024 af, Depth> 1.64"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 2-Year Rainfall=2.79"
Area (ac) CN Description
* 0.045 98 Existing Roof
* 0.064 98 Proposed Asphalt/Concrete
0.063 74 >75% Grass cover, Good, HSG C
0.172 89 Weighted Average
0.063 36.63% Pervious Area
0.109 63.37% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry,
Subcatchment P2: To Jefferson St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
MSE 24-hr 3
2-Year Rainfall=2.79"
Runoff Area=0.172 ac
Runoff Volume=0.024 af
Runoff Depth>1.64"
Tc=6.0 min
CN=89
0.52 cfs
Page 99 of 161
Proposed Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 14HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P3: To Clarence St
Runoff = 0.10 cfs @ 12.26 hrs, Volume= 0.007 af, Depth> 0.78"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 2-Year Rainfall=2.79"
Area (ac) CN Description
* 0.006 98 Proposed Asphalt
0.096 74 >75% Grass cover, Good, HSG C
0.102 75 Weighted Average
0.096 94.12% Pervious Area
0.006 5.88% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
15.1 100 0.0080 0.11 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
0.3 25 0.0100 1.50 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
15.4 125 Total
Subcatchment P3: To Clarence St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.11
0.105
0.1
0.095
0.09
0.085
0.08
0.075
0.07
0.065
0.06
0.055
0.05
0.045
0.04
0.035
0.03
0.025
0.02
0.015
0.01
0.005
0
MSE 24-hr 3
2-Year Rainfall=2.79"
Runoff Area=0.102 ac
Runoff Volume=0.007 af
Runoff Depth>0.78"
Flow Length=125'
Tc=15.4 min
CN=75
0.10 cfs
Page 100 of 161
Proposed Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 15HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Pond UD: Underground Detention
[82] Warning: Early inflow requires earlier time span
Inflow Area = 0.937 ac,100.00% Impervious, Inflow Depth > 2.47" for 2-Year event
Inflow = 3.71 cfs @ 12.13 hrs, Volume= 0.193 af
Outflow = 1.06 cfs @ 12.32 hrs, Volume= 0.176 af, Atten= 72%, L ag= 11.4 min
Discarded = 0.00 cfs @ 12.32 hrs, Volume= 0.003 af
Primary = 1.05 cfs @ 12.32 hrs, Volume= 0.173 af
Routed to Link P : Proposed Total
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 784.93' @ 12.32 hrs Surf.Area= 0.059 ac Storage= 0.083 af
Plug-Flow detention time= 83.7 min calculated for 0.175 af (91% of inflow)
Center-of-Mass det. time= 55.7 min ( 796.2 - 740.5 )
Volume Invert Avail.Storage Storage Description
#1A 782.94' 0.054 af 42.25'W x 60.70'L x 3.75'H Field A
0.221 af Overall - 0.085 af Embedded = 0.136 af x 40.0% Voids
#2A 783.44' 0.085 af ADS_StormTech SC-800 +Cap x 72 Inside #1
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
72 Chambers in 9 Rows
Cap Storage= 3.4 cf x 2 x 9 rows = 61.6 cf
0.139 af Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 782.94' 0.040 in/hr Exfiltration over Surface area
Conductivity to Groundwater Elevation = 775.00'
#2 Primary 783.44' 12.0" Round 12" Outlet Pipe
L= 71.0' CPP, projecting, no headwall, Ke= 0.900
Inlet / Outlet Invert= 783.44' / 783.20' S= 0.0034 '/' Cc= 0.900
n= 0.012 Corrugated PP, smooth interior, Flow Area= 0.79 sf
#3 Device 2 783.44' 6.0" Vert. Orifice 1 C= 0.600 Limited to weir flow at low heads
#4 Device 2 785.00' 6.0" Vert. Orifice 2 X 3.00 C= 0.600
Limited to weir flow at low heads
#5 Device 2 786.25' 4.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s)
Discarded OutFlow Max=0.00 cfs @ 12.32 hrs HW=784.93' (Free Discharge)
1=Exfiltration ( Controls 0.00 cfs)
Primary OutFlow Max=1.05 cfs @ 12.32 hrs HW=784.93' (Free Discharge)
2=12" Outlet Pipe (Passes 1.05 cfs of 2.76 cfs potential flow)
3=Orifice 1 (Orifice Controls 1.05 cfs @ 5.36 fps)
4=Orifice 2 ( Controls 0.00 cfs)
5=Sharp-Crested Rectangular Weir ( Controls 0.00 cfs)
Page 101 of 161
Proposed Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 16HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond UD: Underground Detention - Chamber Wizard Field A
Chamber Model = ADS_StormTech SC-800 +Cap (ADS StormTech® SC-800 with cap volume)
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
Cap Storage= 3.4 cf x 2 x 9 rows = 61.6 cf
51.0" Wide + 3.0" Spacing = 54.0" C-C Row Spacing
8 Chambers/Row x 7.12' Long +0.88' Cap Length x 2 = 58.70' Row Length +12.0" End Stone x 2 = 60.70'
Base Length
9 Rows x 51.0" Wide + 3.0" Spacing x 8 + 12.0" Side Stone x 2 = 42.25' Base Width
6.0" Stone Base + 33.0" Chamber Height + 6.0" Stone Cover = 3.75' Field Height
72 Chambers x 50.6 cf + 3.4 cf Cap Volume x 2 x 9 Rows = 3,704.2 cf Chamber Storage
9,617.2 cf Field - 3,704.2 cf Chambers = 5,913.0 cf Stone x 40.0% Voids = 2,365.2 cf Stone Storage
Chamber Storage + Stone Storage = 6,069.4 cf = 0.139 af
Overall Storage Efficiency = 63.1%
Overall System Size = 60.70' x 42.25' x 3.75'
72 Chambers
356.2 cy Field
219.0 cy Stone
Page 102 of 161
Proposed Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 17HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond UD: Underground Detention
Inflow
Outflow
Discarded
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
4
3
2
1
0
Inflow Area=0.937 ac
Peak Elev=784.93'
Storage=0.083 af
3.71 cfs
1.06 cfs
0.00 cfs
1.05 cfs
Page 103 of 161
Proposed Conditions
MSE 24-hr 3 2-Year Rainfall=2.79"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 18HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Link P: Proposed Total
Inflow Area = 1.445 ac, 81.80% Impervious, Inflow Depth > 1.93" for 2-Year event
Inflow = 2.03 cfs @ 12.17 hrs, Volume= 0.232 af
Primary = 2.03 cfs @ 12.17 hrs, Volume= 0.232 af, Atten= 0%, La g= 0.0 min
Primary outflow = Inflow, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Link P: Proposed Total
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
2
1
0
Inflow Area=1.445 ac
2.03 cfs
2.03 cfs
Page 104 of 161
Proposed Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 19HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P1: To 6" Culvert
Runoff = 0.88 cfs @ 12.19 hrs, Volume= 0.048 af, Depth> 2.47"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 10-Year Rainfall=3.93"
Area (ac) CN Description
* 0.008 98 Proposed Sidewalk
* 0.122 98 Existing Asphalt/Concrete
0.104 74 >75% Grass cover, Good, HSG C
0.234 87 Weighted Average
0.104 44.44% Pervious Area
0.130 55.56% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
9.4 92 0.0220 0.16 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
1.4 135 0.0113 1.59 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
10.8 227 Total
Subcatchment P1: To 6" Culvert
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.95
0.9
0.85
0.8
0.75
0.7
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
MSE 24-hr 3
10-Year Rainfall=3.93"
Runoff Area=0.234 ac
Runoff Volume=0.048 af
Runoff Depth>2.47"
Flow Length=227'
Tc=10.8 min
CN=87
0.88 cfs
Page 105 of 161
Proposed Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 20HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P1a: To Underground Detention
Runoff = 5.27 cfs @ 12.13 hrs, Volume= 0.278 af, Depth> 3.56"
Routed to Pond UD : Underground Detention
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 10-Year Rainfall=3.93"
Area (ac) CN Description
* 0.057 98 Existing Building
* 0.168 98 Proposed Concrete
* 0.400 98 Proposed parking lots
* 0.312 98 Proposed Artificial Turf
0.937 98 Weighted Average
0.937 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry,
Subcatchment P1a: To Underground Detention
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
5
4
3
2
1
0
MSE 24-hr 3
10-Year Rainfall=3.93"
Runoff Area=0.937 ac
Runoff Volume=0.278 af
Runoff Depth>3.56"
Tc=6.0 min
CN=98
5.27 cfs
Page 106 of 161
Proposed Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 21HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P2: To Jefferson St
Runoff = 0.82 cfs @ 12.13 hrs, Volume= 0.038 af, Depth> 2.66"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 10-Year Rainfall=3.93"
Area (ac) CN Description
* 0.045 98 Existing Roof
* 0.064 98 Proposed Asphalt/Concrete
0.063 74 >75% Grass cover, Good, HSG C
0.172 89 Weighted Average
0.063 36.63% Pervious Area
0.109 63.37% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry,
Subcatchment P2: To Jefferson St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.9
0.85
0.8
0.75
0.7
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
MSE 24-hr 3
10-Year Rainfall=3.93"
Runoff Area=0.172 ac
Runoff Volume=0.038 af
Runoff Depth>2.66"
Tc=6.0 min
CN=89
0.82 cfs
Page 107 of 161
Proposed Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 22HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P3: To Clarence St
Runoff = 0.21 cfs @ 12.25 hrs, Volume= 0.013 af, Depth> 1.53"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 10-Year Rainfall=3.93"
Area (ac) CN Description
* 0.006 98 Proposed Asphalt
0.096 74 >75% Grass cover, Good, HSG C
0.102 75 Weighted Average
0.096 94.12% Pervious Area
0.006 5.88% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
15.1 100 0.0080 0.11 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
0.3 25 0.0100 1.50 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
15.4 125 Total
Subcatchment P3: To Clarence St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.23
0.22
0.21
0.2
0.19
0.18
0.17
0.16
0.15
0.14
0.13
0.12
0.11
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
MSE 24-hr 3
10-Year Rainfall=3.93"
Runoff Area=0.102 ac
Runoff Volume=0.013 af
Runoff Depth>1.53"
Flow Length=125'
Tc=15.4 min
CN=75
0.21 cfs
Page 108 of 161
Proposed Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 23HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Pond UD: Underground Detention
[82] Warning: Early inflow requires earlier time span
Inflow Area = 0.937 ac,100.00% Impervious, Inflow Depth > 3.56" for 10-Year event
Inflow = 5.27 cfs @ 12.13 hrs, Volume= 0.278 af
Outflow = 2.54 cfs @ 12.24 hrs, Volume= 0.260 af, Atten= 52%, L ag= 6.7 min
Discarded = 0.00 cfs @ 12.24 hrs, Volume= 0.003 af
Primary = 2.54 cfs @ 12.24 hrs, Volume= 0.256 af
Routed to Link P : Proposed Total
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 785.45' @ 12.24 hrs Surf.Area= 0.059 ac Storage= 0.104 af
Plug-Flow detention time= 73.2 min calculated for 0.259 af (93% of inflow)
Center-of-Mass det. time= 49.9 min ( 787.0 - 737.1 )
Volume Invert Avail.Storage Storage Description
#1A 782.94' 0.054 af 42.25'W x 60.70'L x 3.75'H Field A
0.221 af Overall - 0.085 af Embedded = 0.136 af x 40.0% Voids
#2A 783.44' 0.085 af ADS_StormTech SC-800 +Cap x 72 Inside #1
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
72 Chambers in 9 Rows
Cap Storage= 3.4 cf x 2 x 9 rows = 61.6 cf
0.139 af Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 782.94' 0.040 in/hr Exfiltration over Surface area
Conductivity to Groundwater Elevation = 775.00'
#2 Primary 783.44' 12.0" Round 12" Outlet Pipe
L= 71.0' CPP, projecting, no headwall, Ke= 0.900
Inlet / Outlet Invert= 783.44' / 783.20' S= 0.0034 '/' Cc= 0.900
n= 0.012 Corrugated PP, smooth interior, Flow Area= 0.79 sf
#3 Device 2 783.44' 6.0" Vert. Orifice 1 C= 0.600 Limited to weir flow at low heads
#4 Device 2 785.00' 6.0" Vert. Orifice 2 X 3.00 C= 0.600
Limited to weir flow at low heads
#5 Device 2 786.25' 4.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s)
Discarded OutFlow Max=0.00 cfs @ 12.24 hrs HW=785.44' (Free Discharge)
1=Exfiltration ( Controls 0.00 cfs)
Primary OutFlow Max=2.51 cfs @ 12.24 hrs HW=785.44' (Free Discharge)
2=12" Outlet Pipe (Passes 2.51 cfs of 3.61 cfs potential flow)
3=Orifice 1 (Orifice Controls 1.25 cfs @ 6.38 fps)
4=Orifice 2 (Orifice Controls 1.26 cfs @ 2.27 fps)
5=Sharp-Crested Rectangular Weir ( Controls 0.00 cfs)
Page 109 of 161
Proposed Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 24HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond UD: Underground Detention - Chamber Wizard Field A
Chamber Model = ADS_StormTech SC-800 +Cap (ADS StormTech® SC-800 with cap volume)
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
Cap Storage= 3.4 cf x 2 x 9 rows = 61.6 cf
51.0" Wide + 3.0" Spacing = 54.0" C-C Row Spacing
8 Chambers/Row x 7.12' Long +0.88' Cap Length x 2 = 58.70' Row Length +12.0" End Stone x 2 = 60.70'
Base Length
9 Rows x 51.0" Wide + 3.0" Spacing x 8 + 12.0" Side Stone x 2 = 42.25' Base Width
6.0" Stone Base + 33.0" Chamber Height + 6.0" Stone Cover = 3.75' Field Height
72 Chambers x 50.6 cf + 3.4 cf Cap Volume x 2 x 9 Rows = 3,704.2 cf Chamber Storage
9,617.2 cf Field - 3,704.2 cf Chambers = 5,913.0 cf Stone x 40.0% Voids = 2,365.2 cf Stone Storage
Chamber Storage + Stone Storage = 6,069.4 cf = 0.139 af
Overall Storage Efficiency = 63.1%
Overall System Size = 60.70' x 42.25' x 3.75'
72 Chambers
356.2 cy Field
219.0 cy Stone
Page 110 of 161
Proposed Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 25HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond UD: Underground Detention
Inflow
Outflow
Discarded
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
5
4
3
2
1
0
Inflow Area=0.937 ac
Peak Elev=785.45'
Storage=0.104 af
5.27 cfs
2.54 cfs
0.00 cfs
2.54 cfs
Page 111 of 161
Proposed Conditions
MSE 24-hr 3 10-Year Rainfall=3.93"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 26HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Link P: Proposed Total
Inflow Area = 1.445 ac, 81.80% Impervious, Inflow Depth > 2.95" for 10-Year event
Inflow = 4.05 cfs @ 12.21 hrs, Volume= 0.356 af
Primary = 4.05 cfs @ 12.21 hrs, Volume= 0.356 af, Atten= 0%, La g= 0.0 min
Primary outflow = Inflow, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Link P: Proposed Total
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
4
3
2
1
0
Inflow Area=1.445 ac
4.05 cfs
4.05 cfs
Page 112 of 161
Proposed Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 27HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P1: To 6" Culvert
Runoff = 1.56 cfs @ 12.18 hrs, Volume= 0.088 af, Depth> 4.54"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 100-Year Rainfall=6.19"
Area (ac) CN Description
* 0.008 98 Proposed Sidewalk
* 0.122 98 Existing Asphalt/Concrete
0.104 74 >75% Grass cover, Good, HSG C
0.234 87 Weighted Average
0.104 44.44% Pervious Area
0.130 55.56% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
9.4 92 0.0220 0.16 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
1.4 135 0.0113 1.59 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
10.8 227 Total
Subcatchment P1: To 6" Culvert
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
MSE 24-hr 3
100-Year Rainfall=6.19"
Runoff Area=0.234 ac
Runoff Volume=0.088 af
Runoff Depth>4.54"
Flow Length=227'
Tc=10.8 min
CN=87
1.56 cfs
Page 113 of 161
Proposed Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 28HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P1a: To Underground Detention
Runoff = 8.34 cfs @ 12.13 hrs, Volume= 0.445 af, Depth> 5.70"
Routed to Pond UD : Underground Detention
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 100-Year Rainfall=6.19"
Area (ac) CN Description
* 0.057 98 Existing Building
* 0.168 98 Proposed Concrete
* 0.400 98 Proposed parking lots
* 0.312 98 Proposed Artificial Turf
0.937 98 Weighted Average
0.937 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry,
Subcatchment P1a: To Underground Detention
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
9
8
7
6
5
4
3
2
1
0
MSE 24-hr 3
100-Year Rainfall=6.19"
Runoff Area=0.937 ac
Runoff Volume=0.445 af
Runoff Depth>5.70"
Tc=6.0 min
CN=98
8.34 cfs
Page 114 of 161
Proposed Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 29HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P2: To Jefferson St
Runoff = 1.41 cfs @ 12.13 hrs, Volume= 0.068 af, Depth> 4.76"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 100-Year Rainfall=6.19"
Area (ac) CN Description
* 0.045 98 Existing Roof
* 0.064 98 Proposed Asphalt/Concrete
0.063 74 >75% Grass cover, Good, HSG C
0.172 89 Weighted Average
0.063 36.63% Pervious Area
0.109 63.37% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry,
Subcatchment P2: To Jefferson St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
1
0
MSE 24-hr 3
100-Year Rainfall=6.19"
Runoff Area=0.172 ac
Runoff Volume=0.068 af
Runoff Depth>4.76"
Tc=6.0 min
CN=89
1.41 cfs
Page 115 of 161
Proposed Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 30HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Subcatchment P3: To Clarence St
Runoff = 0.45 cfs @ 12.24 hrs, Volume= 0.028 af, Depth> 3.29"
Routed to Link P : Proposed Total
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
MSE 24-hr 3 100-Year Rainfall=6.19"
Area (ac) CN Description
* 0.006 98 Proposed Asphalt
0.096 74 >75% Grass cover, Good, HSG C
0.102 75 Weighted Average
0.096 94.12% Pervious Area
0.006 5.88% Impervious Area
Tc Length Slope Velocity Capacity Description
(min) (feet) (ft/ft) (ft/sec) (cfs)
15.1 100 0.0080 0.11 Sheet Flow,
Grass: Short n= 0.150 P2= 2.80"
0.3 25 0.0100 1.50 Shallow Concentrated Flow,
Grassed Waterway Kv= 15.0 fps
15.4 125 Total
Subcatchment P3: To Clarence St
Runoff
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
0.48
0.46
0.44
0.42
0.4
0.38
0.36
0.34
0.32
0.3
0.28
0.26
0.24
0.22
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
MSE 24-hr 3
100-Year Rainfall=6.19"
Runoff Area=0.102 ac
Runoff Volume=0.028 af
Runoff Depth>3.29"
Flow Length=125'
Tc=15.4 min
CN=75
0.45 cfs
Page 116 of 161
Proposed Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 31HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Pond UD: Underground Detention
[82] Warning: Early inflow requires earlier time span
Inflow Area = 0.937 ac,100.00% Impervious, Inflow Depth > 5.70" for 100-Year event
Inflow = 8.34 cfs @ 12.13 hrs, Volume= 0.445 af
Outflow = 4.92 cfs @ 12.21 hrs, Volume= 0.425 af, Atten= 41%, L ag= 5.2 min
Discarded = 0.00 cfs @ 12.21 hrs, Volume= 0.003 af
Primary = 4.92 cfs @ 12.21 hrs, Volume= 0.422 af
Routed to Link P : Proposed Total
Routing by Stor-Ind method, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Peak Elev= 786.65' @ 12.21 hrs Surf.Area= 0.059 ac Storage= 0.138 af
Plug-Flow detention time= 57.3 min calculated for 0.424 af (95% of inflow)
Center-of-Mass det. time= 40.4 min ( 774.4 - 734.0 )
Volume Invert Avail.Storage Storage Description
#1A 782.94' 0.054 af 42.25'W x 60.70'L x 3.75'H Field A
0.221 af Overall - 0.085 af Embedded = 0.136 af x 40.0% Voids
#2A 783.44' 0.085 af ADS_StormTech SC-800 +Cap x 72 Inside #1
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
72 Chambers in 9 Rows
Cap Storage= 3.4 cf x 2 x 9 rows = 61.6 cf
0.139 af Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 782.94' 0.040 in/hr Exfiltration over Surface area
Conductivity to Groundwater Elevation = 775.00'
#2 Primary 783.44' 12.0" Round 12" Outlet Pipe
L= 71.0' CPP, projecting, no headwall, Ke= 0.900
Inlet / Outlet Invert= 783.44' / 783.20' S= 0.0034 '/' Cc= 0.900
n= 0.012 Corrugated PP, smooth interior, Flow Area= 0.79 sf
#3 Device 2 783.44' 6.0" Vert. Orifice 1 C= 0.600 Limited to weir flow at low heads
#4 Device 2 785.00' 6.0" Vert. Orifice 2 X 3.00 C= 0.600
Limited to weir flow at low heads
#5 Device 2 786.25' 4.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s)
Discarded OutFlow Max=0.00 cfs @ 12.21 hrs HW=786.61' (Free Discharge)
1=Exfiltration ( Controls 0.00 cfs)
Primary OutFlow Max=4.88 cfs @ 12.21 hrs HW=786.61' (Free Discharge)
2=12" Outlet Pipe (Inlet Controls 4.88 cfs @ 6.21 fps)
3=Orifice 1 (Passes < 1.62 cfs potential flow)
4=Orifice 2 (Passes < 3.31 cfs potential flow)
5=Sharp-Crested Rectangular Weir (Passes < 2.79 cfs potential flow)
Page 117 of 161
Proposed Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 32HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond UD: Underground Detention - Chamber Wizard Field A
Chamber Model = ADS_StormTech SC-800 +Cap (ADS StormTech® SC-800 with cap volume)
Effective Size= 45.0"W x 33.0"H => 7.11 sf x 7.12'L = 50.6 cf
Overall Size= 51.0"W x 33.0"H x 7.55'L with 0.43' Overlap
Cap Storage= 3.4 cf x 2 x 9 rows = 61.6 cf
51.0" Wide + 3.0" Spacing = 54.0" C-C Row Spacing
8 Chambers/Row x 7.12' Long +0.88' Cap Length x 2 = 58.70' Row Length +12.0" End Stone x 2 = 60.70'
Base Length
9 Rows x 51.0" Wide + 3.0" Spacing x 8 + 12.0" Side Stone x 2 = 42.25' Base Width
6.0" Stone Base + 33.0" Chamber Height + 6.0" Stone Cover = 3.75' Field Height
72 Chambers x 50.6 cf + 3.4 cf Cap Volume x 2 x 9 Rows = 3,704.2 cf Chamber Storage
9,617.2 cf Field - 3,704.2 cf Chambers = 5,913.0 cf Stone x 40.0% Voids = 2,365.2 cf Stone Storage
Chamber Storage + Stone Storage = 6,069.4 cf = 0.139 af
Overall Storage Efficiency = 63.1%
Overall System Size = 60.70' x 42.25' x 3.75'
72 Chambers
356.2 cy Field
219.0 cy Stone
Page 118 of 161
Proposed Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 33HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Pond UD: Underground Detention
Inflow
Outflow
Discarded
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
9
8
7
6
5
4
3
2
1
0
Inflow Area=0.937 ac
Peak Elev=786.65'
Storage=0.138 af
8.34 cfs
4.92 cfs
0.00 cfs
4.92 cfs
Page 119 of 161
Proposed Conditions
MSE 24-hr 3 100-Year Rainfall=6.19"Opportunities Inc
Printed 9/4/2026Prepared by PSE
Page 34HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Summary for Link P: Proposed Total
Inflow Area = 1.445 ac, 81.80% Impervious, Inflow Depth > 5.04" for 100-Year event
Inflow = 8.00 cfs @ 12.17 hrs, Volume= 0.607 af
Primary = 8.00 cfs @ 12.17 hrs, Volume= 0.607 af, Atten= 0%, La g= 0.0 min
Primary outflow = Inflow, Time Span= 5.00-20.00 hrs, dt= 0.05 hrs
Link P: Proposed Total
Inflow
Primary
Hydrograph
Time (hours)
201918171615141312111098765
Flow (cfs)
8
7
6
5
4
3
2
1
0
Inflow Area=1.445 ac
8.00 cfs
8.00 cfs
Page 120 of 161
Proposed Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 35HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Subcatchment P1: To 6" Culvert
Event Rainfall
(inches)
Runoff
(cfs)
Volume
(acre-feet)
1-Year 2.46 0.44 0.024
2-Year 2.79 0.54 0.029
10-Year 3.93 0.88 0.048
100-Year 6.19 1.56 0.088
Page 121 of 161
Proposed Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 36HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Subcatchment P1a: To Underground Detention
Event Rainfall
(inches)
Runoff
(cfs)
Volume
(acre-feet)
1-Year 2.46 3.26 0.168
2-Year 2.79 3.71 0.193
10-Year 3.93 5.27 0.278
100-Year 6.19 8.34 0.445
Page 122 of 161
Proposed Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 37HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Subcatchment P2: To Jefferson St
Event Rainfall
(inches)
Runoff
(cfs)
Volume
(acre-feet)
1-Year 2.46 0.43 0.020
2-Year 2.79 0.52 0.024
10-Year 3.93 0.82 0.038
100-Year 6.19 1.41 0.068
Page 123 of 161
Proposed Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 38HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Subcatchment P3: To Clarence St
Event Rainfall
(inches)
Runoff
(cfs)
Volume
(acre-feet)
1-Year 2.46 0.07 0.005
2-Year 2.79 0.10 0.007
10-Year 3.93 0.21 0.013
100-Year 6.19 0.45 0.028
Page 124 of 161
Proposed Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 39HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Pond UD: Underground Detention
Event Inflow
(cfs)
Outflow
(cfs)
Discarded
(cfs)
Primary
(cfs)
Elevation
(feet)
Storage
(acre-feet)
1-Year 3.26 0.96 0.00 0.96 784.72 0.074
2-Year 3.71 1.06 0.00 1.05 784.93 0.083
10-Year 5.27 2.54 0.00 2.54 785.45 0.104
100-Year 8.34 4.92 0.00 4.92 786.65 0.138
Page 125 of 161
Proposed Conditions
Multi-Event TablesOpportunities Inc
Printed 9/4/2026Prepared by PSE
Page 40HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
Events for Link P: Proposed Total
Event Inflow
(cfs)
Primary
(cfs)
Volume
(acre-feet)
1-Year 1.75 1.75 0.197
2-Year 2.03 2.03 0.232
10-Year 4.05 4.05 0.356
100-Year 8.00 8.00 0.607
Page 126 of 161
Proposed Conditions
Table of ContentsOpportunities Inc
Printed 9/4/2026Prepared by PSE
HydroCAD® 10.20-9a s/n 14207 © 2026 HydroCAD Software Solutions LLC
TABLE OF CONTENTS
Project Reports
1 Routing Diagram
2 Rainfall Events Listing
1-Year Event
3 Subcat P1: To 6" Culvert
4 Subcat P1a: To Underground Detention
5 Subcat P2: To Jefferson St
6 Subcat P3: To Clarence St
7 Pond UD: Underground Detention
10 Link P: Proposed Total
2-Year Event
11 Subcat P1: To 6" Culvert
12 Subcat P1a: To Underground Detention
13 Subcat P2: To Jefferson St
14 Subcat P3: To Clarence St
15 Pond UD: Underground Detention
18 Link P: Proposed Total
10-Year Event
19 Subcat P1: To 6" Culvert
20 Subcat P1a: To Underground Detention
21 Subcat P2: To Jefferson St
22 Subcat P3: To Clarence St
23 Pond UD: Underground Detention
26 Link P: Proposed Total
100-Year Event
27 Subcat P1: To 6" Culvert
28 Subcat P1a: To Underground Detention
29 Subcat P2: To Jefferson St
30 Subcat P3: To Clarence St
31 Pond UD: Underground Detention
34 Link P: Proposed Total
Multi-Event Tables
35 Subcat P1: To 6" Culvert
36 Subcat P1a: To Underground Detention
37 Subcat P2: To Jefferson St
38 Subcat P3: To Clarence St
39 Pond UD: Underground Detention
40 Link P: Proposed Total
Page 127 of 161
Page 128 of 161
Data file name: W:\Projects\SR-65-26\SWMP\Opprotunities Inc.mdb
WinSLAMM Version 10.5.2
Rain file name: C:\WinSLAMM Files\Rain Files\WisReg - Madison WI 1981.RAN
Particulate Solids Concentration file name: C:\WinSLAMM Files\v10.1 WI_AVG01.pscx
Runoff Coefficient file name: C:\WinSLAMM Files\WI_SL06 Dec06.rsvx
Residential Street Delivery file name: C:\WinSLAMM Files\WI_Res and Other Urban Dec06.std
Institutional Street Delivery file name: C:\WinSLAMM Files\WI_Com Inst Indust Dec06.std
Commercial Street Delivery file name: C:\WinSLAMM Files\WI_Com Inst Indust Dec06.std
Industrial Street Delivery file name: C:\WinSLAMM Files\WI_Com Inst Indust Dec06.std
Other Urban Street Delivery file name: C:\WinSLAMM Files\WI_Res and Other Urban Dec06.std
Freeway Street Delivery file name: C:\WinSLAMM Files\Freeway Dec06.std
Apply Street Delivery Files to Adjust the After Event Load Street Dirt Mass Balance: False
Pollutant Relative Concentration file name: C:\WinSLAMM Files\WI_GEO03.ppdx
Source Area PSD and Peak to Average Flow Ratio File: C:\WinSLAMM Files\NURP Source Area PSD Files.csv
Cost Data file name:
Seed for random number generator: -42
Study period starting date: 03/12/81 Study period ending date: 12/02/81
Start of Winter Season: 12/02 End of Winter Season: 03/12
Date: 09-04-2026 Time: 10:57:58
Site information:
LU# 1 - Commercial: To Underground Detention (P1a) Total area (ac): 0.937
1 - Roofs 1: 0.057 ac. Pitched Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
13 - Paved Parking 1: 0.400 ac. Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
31 - Sidewalks 1: 0.168 ac. Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
63 - Paved Playground 1: 0.312 ac. Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
LU# 2 - Commercial: To 6" Culvert (P1 Disturbed)) Total area (ac): 0.095
31 - Sidewalks 1: 0.008 ac. Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
51 - Small Landscaped Areas 1: 0.087 ac. Normal Silty Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
LU# 3 - Commercial: To Jefferson St (P2) Total area (ac): 0.172
1 - Roofs 1: 0.045 ac. Pitched Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
13 - Paved Parking 1: 0.053 ac. Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
31 - Sidewalks 1: 0.011 ac. Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
51 - Small Landscaped Areas 1: 0.063 ac. Normal Silty Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
LU# 4 - Commercial: To Clarence St (P3) Total area (ac): 0.102
25 - Driveways 1: 0.006 ac. Connected Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
51 - Small Landscaped Areas 1: 0.096 ac. Normal Silty Source Area PSD File: C:\WinSLAMM Files\NURP.cpz
Page 129 of 161
Control Practice 1: Isolator Row CP# 1 (DS) - DS Isolator Row # 1
Total available system length (ft) = 66
Total available system width (ft) = 43
Available height from chamber base to surface (ft) = 4.00
Number of isolator rows = 1
Native soil infiltration rate (in/hr) = 0.04
Assumed stone porosity () = 0.40
Sizing option: Use all available area
Selected Chamber Information
Chamber type: SC-800
Chamber height (in): 30.00
Chamber width (in): 51.00
Chamber segment length (in): 85.40
Final storage volume (cf): 5698
Number of rows: 9
Row length (ft): 56.9
Total system length (ft): 512.4
Total system width (ft): 38.3
Number of chambers: 72
Overflow weir invert elevation (ft) = 2.81
Orifice 1 invert elevation (ft) = 0.00
Orifice 1 diameter (ft) = 0.50
Drain Tile Not Present
Page 130 of 161
SLAMM for Windows Version 10.5.2
(c) Copyright Robert Pitt and John Voorhees 2019, All Rights Reserved
Data file name: W:\Projects\SR-65-26\SWMP\Opprotunities Inc.mdb
WinSLAMM Version 10.5.2
Rain file name: C:\WinSLAMM Files\Rain Files\WisReg - Madison WI 1981.RAN
Particulate Solids Concentration file name: C:\WinSLAMM Files\v10.1 WI_AVG01.pscx
Runoff Coefficient file name: C:\WinSLAMM Files\WI_SL06 Dec06.rsvx
Pollutant Relative Concentration file name: C:\WinSLAMM Files\WI_GEO03.ppdx
Residential Street Delivery file name: C:\WinSLAMM Files\WI_Res and Other Urban Dec06.std
Institutional Street Delivery file name: C:\WinSLAMM Files\WI_Com Inst Indust Dec06.std
Commercial Street Delivery file name: C:\WinSLAMM Files\WI_Com Inst Indust Dec06.std
Industrial Street Delivery file name: C:\WinSLAMM Files\WI_Com Inst Indust Dec06.std
Other Urban Street Delivery file name: C:\WinSLAMM Files\WI_Res and Other Urban Dec06.std
Freeway Street Delivery file name: C:\WinSLAMM Files\Freeway Dec06.std
Apply Street Delivery Files to Adjust the After Event Load Street Dirt Mass Balance: False
Source Area PSD and Peak to Average Flow Ratio File: C:\WinSLAMM Files\NURP Source Area PSD Files.csv
Cost Data file name:
Seed for random number generator: -42
Study period starting date: 03/12/81 Study period ending date: 12/02/81
Start of Winter Season: 12/02 End of Winter Season: 03/12
Model Run Start Date: 03/12/81 Model Run End Date: 12/02/81
Date of run: 09-04-2026 Time of run: 10:57:08
Total Area Modeled (acres): 1.306
Years in Model Run: 0.68
Runoff Percent Particulate Particulate Percent
Volume Runoff Solids Solids Particulate
(cu ft) Volume Conc. Yield Solids
Reduction (mg/L) (lbs) Reduction
Total of all Land Uses without Controls: 84039 - 118.1 619.6 -
Outfall Total with Controls: 77232 8.10% 46. 96 226.4 63.46%
Annualized Total After Outfall Controls: 112759 330.5
Page 131 of 161
NORTH 72°25'55" WEST 251.05'
NORTH 17°32'36" EAST 485.86'
SOUTH 22°14'26" WEST 511.67'
9/4/2026
SWM-3
122 Wisconsin Street, West Bend, WI 53095262.346.7800 www.parishse.com
SWM REPORTOPPORTUNITIES INC.RECREATION AREA815 JEFFERSON STFORT ATKINSON, WI, 53538
\SR-65-26\
STORMSEWERDRAINAGEMAPJDRJDRKJP
Page 132 of 161
WORK SHEET FOR STORM SEWER DESIGN
PROJECT: Opportunities Recreation Area Computed by: Kevin Parish
DATE: Checked by: Kevin Parish
Upstream
Structure
Downstream
Structure
Runoff Coeff.
Area
Design Storm
Rain Intensity
Direct Runoff
Other Runoff
Sewer Size
Slope of Sewer
Capacity
Flowing Full
( C ) ( A ) ( I ) Q=C*I* A
Acres Yr. In./Hr. CFS CFS CFS GPM In. Ft./Ft. CFS GPM
0.89 0.28 100 10.60 2.60 0.00 2.60 1166 12 0.0060 3.00 1345
0.89 0.12 100 10.60 1.13 2.60 3.73 1675 12 0.0100 3.87 1737
0.89 0.06 100 10.60 0.54 0.00 0.54 241 8 0.0137 1.54 689
0.89 0.07 100 10.60 0.64 0.00 0.64 287 8 0.0100 1.31 589
0.89 0.04 100 10.60 0.36 1.18 1.53 687 10 0.0146 2.88 1291
0.72 0.07 10 7.20 0.35 0.00 0.35 155 10 0.0050 1.68 755
* C
10= 0.72
* C100= 0.89 0.012 n=
10.60 I = rainfall intensity for Fort Atkinson, Wisconsin from NOAA Atlas 14, Vol. 8, Ver. 2
A = Drainage area to structure. 100 Year Storm10 Year Storm
9/4/2026
LOCATION
= Commercial Soil B, Slope 2-6% from the FDM Procedure 13-10-5 Figure 2.
= Commercial Soil B, Slope 2-6% from the FDM Procedure 13-10-5 Figure 2.
RAINFALL - RUNOFF
Design Runoff
BASIN
7.20
Manning's Roughness Coefficient
CB #5.1 CB #5
CB #5 Stm Mh #4
CB #6 Ex Stm Mh
SEWER
CB #5.2 CB #5
Inlet #3.1 Inlet #3
Inlet #3 STM MH #2
Page 133 of 161
1
STORM WATER FACILITIES LOCATIONS
Page 134 of 161
2
OPERATION AND MAINTENANCE PLAN
STORM WATER MAINTENANCE STANDARDS
The maintenance activities listed below are aimed to ensure the stormwater practices continue serving their intended
functions in perpetuity. The list of activities is not all-inclusive, but rather indicates the minimum type of maintenance
that can be expected for this particular site.
INSPECTION, MAINTENANCE, & PROHIBITIONS
All components of the storm water system shall be inspected at least semi-annually in early Spring and early Autumn.
Repairs will be made whenever the performance of a storm water control device is compromised as described below.
Owner shall maintain records of all inspection and maintenance activities.
STORM SEWER
• Visual inspection of components shall be performed and debris removed from inlets and storm sewer manholes
semi-annually in spring and fall.
• Repair inlet/outlet areas that are damaged or show signs of erosion.
• Repairs must restore the component to the specifications of the original plan.
STORMTECH UNDERGROUND DETENTION SYSTEM
Owner shall install an underground detention system in accordance with plans approved by City Engineer. Visual
inspection of the underground detention system shall be performed semi-annually. Any alterations to approved
underground detention system shall be approved by City Engineer. Owner shall maintain records of inspections, cleaning
and replacement of the underground detention system all in accordance with this agreement.
Inspect Isolator Row for sediment every three (3) months at a minimum. Using a flashlight and stadia rod, measure depth
of sediment and record results on maintenance log. If sediment is at, or above, 3 inch depth, clean out Isolator Row using
the JetVac process. A fixed culvert cleaning nozzle with rear facing nozzle spread of 45 inches or more is preferable.
Apply multiple passes of JetVac until backflush water is clean and vacuum manhole sump as required. Replace all caps,
lids and covers, record observations and actions. Also, inspect & clean catch basins and inlet.
Visually inspect Infiltration Rows through the inspection ports for standing water every six (6) months at a minimum.
Inspections should coincide with a rain event to determine if the system shows standing water beyond 72 hours of the rain
event. If system shows standing water after 72 hours following a rain event, the system shall be repaired to restore the
performance of the system to meet the stormwater management design approved by the City of Mequon.
Page 135 of 161
Page 136 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 1 of 9
COMMERCIAL OUTDOOR
D-Series Size 0
LED Area Luminaire
Specifications
Catalog
Number
Notes
Type
Introduction
The modern styling of the D-Series features a
highly refined aesthetic that blends seamlessly
with its environment. The D-Series offers the
benefits of the latest in LED technology into
a high performance, high efficacy, long-life
luminaire.
The photometric performance results in sites
with excellent uniformity, greater pole spacing
and lower power density. D-Series outstanding
photometry aids in reducing the number of
poles required in area lighting applications, with
typical energy savings of 70% and expected
service life of over 100,000 hours.
EPA: 0.44 ft2
(0.04 m2)
Length: 26.18"
(66.5 cm)
Width: 14.06"
(35.7 cm)
Height H1: 2.26"
(5.7 cm)
Height H2: 7.46"
(18.9 cm)
Weight: 23 lbs
(10.4 kg)
Hit the Tab key or mouse over the page to see all interactive elements.
Ordering Information EXAMPLE: DSX0 LED P6 40K 70CRI T3M MVOLT SPA NLTAIR2 PIRHN DDBXD
DSX0 LED
Series LEDs Color temperature 2 Color Rendering
Index 2 Distribution Voltage Mounting
DSX0 LED Forward optics
P1 P5
P2 P6
P3 P7
P4
Rotated optics
P10 1 P12 1
P11 1 P13 1
(this section 70CRI only)
30K 3000K
40K 4000K
50K 5000K
27K 2700K
30K 3000K
35K 3500K
40K 4000K
50K 5000K
70CRI
70CRI
70CRI
80CRI
80CRI
80CRI
80CRI
80CRI
AFR Automotive front
row
T1S Type I short
T2M Type II medium
T3M Type III medium
T3LG Type III low glare 3
T4M Type IV medium
T4LG Type IV low glare 3
TFTM Forward throw
medium
T5M Type V medium
T5LG Type V low glare
T5W Type V wide
BLC3 Type III backlight
control 3
BLC4 Type IV backlight
control 3
LCCO Left corner cutoff 3
RCCO Right corner cutoff 3
MVOLT (120V-277V) 4
HVOLT (347V-480V) 5,6
XVOLT (277V-480V) 7, 8
120 16, 24
208 16, 24
240 16, 24
277 16, 24
347 16, 24
480 16, 24
Shipped included
SPA Square pole mounting (#8
drilling, 3.5" min. SQ pole)
RPA Round pole mounting (#8
drilling, 3" min. RND pole)
SPA5 Square pole mounting (#5
drilling. 3" min. SQ pole) 9
RPA5 Round pole mounting (#5
drilling, 3" min. RND pole) 9
SPA8N Square narrow pole mounting
(#8 drilling, 3" min. SQ pole)
WBA Wall bracket 10
MA Mast arm adapter (mounts on
2 3/8" OD horizontal tenon)
Control options Other options Finish (required)
Shipped installed
NLTAIR2 PIRHN nLight AIR gen 2 enabled with
bi-level motion / ambient sensor,
8-40' mounting height, ambient
sensor enabled at 2fc. 11, 12, 18, 19
PIR High/low, motion/ambient sensor,
8-40’ mounting height, ambient
sensor enabled at 2fc 13, 18, 19
PER NEMA twist-lock receptacle only
(controls ordered separate) 14
PER5 Five-pin receptacle only (controls
ordered separate) 14, 19
PER7 Seven-pin receptacle only
(controls ordered separate) 14, 19
FAO Field adjustable output 15, 19
BL30 Bi-level switched dimming,
30% 16, 19
BL50 Bi-level switched dimming,
50% 16, 19
DMG 0-10v dimming wires pulled
outside fixture (for use with
an external control, ordered
separately) 17
Shipped installed
HS Houseside shield (black finish standard) 20
L90 Left rotated optics 1
R90 Right rotated optics 1
CCE Coastal Construction 21
HA 50°C ambient operation 22
BAA Buy America(n) Act and/or Build America Buy America Qualified
SF Single fuse (120, 277, 347V) 24
DF Double fuse (208, 240, 480V) 24
Shipped separately
EGSR External Glare Shield (reversible, field install required, matches housing finish)
BSDB Bird Spikes (field install required)
DDBXD Dark Bronze
DBLXD Black
DNAXD Natural Aluminum
DWHXD White
DDBTXD Textured dark bronze
DBLBXD Textured black
DNATXD Textured natural aluminum
DWHGXD Textured white
L
H1
W
H2
L
H1
W
H2 Items marked by a shaded background qualify for the Design Select program and ship in 15
days or less. To learn more about Design Select, visit www.acuitybrands.com/designselect.
*See ordering tree for detailsDesign Select options indicated
by this color background.
Page 137 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 2 of 9
COMMERCIAL OUTDOOR
1.750" for
aluminum poles
2.750" - for
other poles
type
Drilling
Ordering Information
Accessories
Ordered and shipped separately.
DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 23
DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 23
DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 23
DSHORT SBK Shorting cap 23
DSX0HS P# House-side shield (enter package number P1-7,
P10-13 in place of #)
DSXRPA (FINISH) Round pole adapter (#8 drilling, specify finish)
DSXRPA5 (FINISH) Round pole adapter #5 drilling (specify finish)
DSXSPA5 (FINISH) Square pole adapter #5 drilling (specify finish)
DSX0EGSR (FINISH) External glare shield (specify finish)
DSX0BSDB (FINISH) Bird spike deterrent bracket (specify finish)
Shield Accessories
NOTES
1 Rotated optics available with packages P10, P11, P12 and P13. Must be combined with option L90 or R90.
2 30K, 40K, and 50K available in 70CRI and 80CRI. 27K and 35K only available with 80CRI. Contact Technical Support for other possible combinations.
3 T3LG, T4LG, BLC3, BLC4, LCCO, RCCO not available with option HS.
4 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz).
5 HVOLT driver operates on any line voltage from 347-480V (50/60 Hz).
6 HVOLT not available with package P1, P2 and P10 when combined with option NLTAIR2 PIRHN or option PIR.
7 XVOLT operates with any voltage between 277V and 480V (50/60 Hz).
8 XVOLT not available in packages P1, P2, or P10. XVOLT not available with fusing (SF or DF). XVOLT also not available in packages P3, P4, P5, P7, P11, P13
when combined with NLTAIR2 PIRHN or PIR.
9 SPA5 and RPA5 for use with #5 drilling only (Not for use with #8 drilling).
10 WBA cannot be combined with Type 5 distributions plus photocell (PER).
11 NLTAIR2 and PIRHN must be ordered together. For more information on nLight Air 2.
12 NLTAIR2 PIRHN not available with other controls including PIR, PER, PER5, PER7, FAO, BL30, BL50 and DMG. NLTAIR2 PIRHN not available with P1, P2 and
P10 using HVOLT. NLTAIR2 PIRHN not available with P1 using MVOLT.
13 PIR not available with NLTAIR2, PER, PER5, PER7, FAO BL30, BL50 and DMG. PIR not available with P1, P2 and P10 using HVOLT.PIR not available with P1
using MVOLT.
14 PER/PER5/PER7 not available with NLTAIR2, PIR, BL30, BL50. Photocell ordered and shipped as a separate line item from Acuity Brands Controls. See
accessories. Shorting Cap included.
15 FAO not available with other dimming control options NLTAIR2 PIRHN, PIR, PER5, PER7, BL30, BL50, or DMG.
16 BL30 and BL50 are not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, FAO and DMG. BL30 or BL50 must specify 120 or 277V.
17 DMG not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, BL30, BL50 and FAO.
18 Reference Motion Sensor Default Settings table on page 4 to see functionality.
19 Reference Controls Options table on page 4.
20 Option HS not available with T3LG, T4LG, BLC3, BLC4, LCCO and RCCO distribution. Also available as a separate accessory; see Accessories information.
21 CCE option not available with option BS and EGSR. Contact Technical Support for availability.
22 Option HA not available with performance packages P6, P7, P12 and P13.
23 Requires luminaire to be specified with PER, PER5 or PER7 option. See Controls Table on page 4.
24 Single fuse (SF) requires 120V, 277V, or 347V. Double fuse (DF) requires 208V, 240V or 480V. XVOLT not available with fusing (SF or DF).
Top of Pole
0.563"
1.325"
0.400"
(2 PLCS)
Template #8
A
Handhole
B
C
D
HANDHOLE ORIENTATION
(from top of pole)
2.650"
Tenon Mounting Slipfitter
Tenon O.D. Mounting Single Unit 2 @ 180 2 @ 90 3 @ 90 3 @120 4 @ 90
2-3/8" RPA AS3-5 190 AS3-5 280 AS3-5 290 AS3-5 390 AS3-5 320 AS3-5 490
2-7/8" RPA AST25-190 AST25-280 AST25-290 AST25-390 AST25-320 AST25-490
4" RPA AST35-190 AST35-280 AST35-290 AST35-390 AST35-320 AST35-490
External Glare Shield (EGSR)
House Side Shield (HS)
Fixture Quantity & Mounting
Configuration Single DM19 2 @ 180 DM28 2 @ 90 DM29 3 @ 90 DM39 3 @ 120 DM32 4 @ 90 DM49
Mounting Type
DSX0 with SPA 0.44 0.88 0.96 1.18 --- 1.16
DSX0 with SPA5, SPA8N 0.51 1.02 1.06 1.26 --- 1.29
DSX0 with RPA, RPA5 0.51 1.02 1.06 1.26 1.24 1.29
DSX0 with MA 0.64 1.28 1.24 1.67 1.70 1.93
DSX0 Area Luminaire - EPA
*Includes luminaire and integral mounting arm. Other tenons, arms, brackets or other accessories are not included in this EPA data.
Minimum Acceptable Outside Pole Dimension
SPA #8 3.5" 3.5" 3.5" 3.5" 3.5"
RPA #8 3" 3" 3" 3" 3" 3"
SPA5 #5 3" 3" 3" 3" 3"
RPA5 #5 3" 3" 3" 3" 3" 3"
SPA8N #8 3" 3" 3" 3" 3"
Mounting Option Drilling
Template Single 2 @ 180 2 @ 90 3 @ 90 3 @ 120 4 @ 90
Head Location Side B Side B & D Side B & C Side B, C & D Round Pole Only Side A, B, C & D
Drill Nomenclature #8 DM19AS DM28AS DM29AS DM39AS DM32AS DM49AS
Page 138 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 3 of 9
COMMERCIAL OUTDOOR
To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s homepage. Photometric Diagrams
Isofootcandle plots for the DSX0 LED P7 40K 70CRI. Distances are in units of mounting height (20').
LEGEND
0.1 fc
0.5 fc
1.0 fc
T1S T2M T3M
4
3
2
1
0
-4
-3
-2
-1
4 3 2 1 0 4321
T3LG
T4M TFTM T4LG T5M
T5W T5LG AFR BLC3
BLC4 LCCO RCCO
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
4 3 2 1 0 43216 5 65
4
3
2
1
0
-4
-3
-2
-1
5
6
-5
-6
Page 139 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 4 of 9
COMMERCIAL OUTDOOR
Performance Data
Current (A)
Performance
Package
LED
Count
Drive
Current (mA) Wattage 120V 208V 240V 277V 347V 480V
Forward Optics
(Non-Rotated)
P1 20 530 34 0.28 0.16 0.14 0.12 0.10 0.07
P2 20 700 45 0.38 0.22 0.19 0.16 0.13 0.09
P3 20 1050 69 0.57 0.33 0.29 0.25 0.20 0.14
P4 20 1400 94 0.78 0.45 0.39 0.34 0.27 0.19
P5 40 700 89 0.75 0.43 0.38 0.33 0.26 0.19
P6 40 1050 136 1.14 0.66 0.57 0.49 0.39 0.29
P7 40 1300 170 1.42 0.82 0.71 0.62 0.49 0.36
Rotated Optics
(Requires L90 or
R90)
P10 30 530 51 0.42 0.24 0.21 0.18 0.15 0.11
P11 30 700 67 0.57 0.33 0.28 0.25 0.20 0.14
P12 30 1050 103 0.86 0.50 0.43 0.37 0.30 0.22
P13 30 1300 129 1.07 0.62 0.54 0.46 0.37 0.27
Electrical Load
Motion Sensor Default Settings
Option Unoccupied Dimmed Level High Level
(when occupied) Phototcell Operation Dwell Time Ramp-up Time Dimming Fade Rate
PIR 30% 100% Enabled @ 2FC 7.5 min 3 sec 5 min
NLTAIR2 PIRHN 30% 100% Enabled @ 2FC 7.5 min 3 sec 5 min
Controls Options
Nomenclature Description Functionality Primary control device Notes
FAO Field adjustable output device installed inside the
luminaire; wired to the driver dimming leads.
Allows the luminaire to be manually dimmed,
effectively trimming the light output.
FAO device Cannot be used with other controls options that need the
0-10V leads
DS (not available on DSX0) Drivers wired independently for 50/50 luminaire
operation
The luminaire is wired to two separate circuits,
allowing for 50/50 operation.
Independently wired drivers Requires two separately switched circuits. Consider nLight
AIR as a more cost effective alternative.
PER5 or PER7 Twist-lock photocell receptacle Compatible with standard twist-lock photocells for
dusk to dawn operation, or advanced control nodes
that provide 0-10V dimming signals.
Twist-lock photocells such as DLL Elite or
advanced control nodes such as ROAM.
Pins 4 & 5 to dimming leads on driver, Pins 6 & 7 are
capped inside luminaire. Cannot be used with other
controls options that need the 0-10V leads.
PIR Motion sensor with integral photocell. Sensor suitable
for 8' to 40' mounting height.
Luminaires dim when no occupancy is detected. Acuity Controls rSBG Cannot be used with other controls options that need the
0-10V leads.
NLTAIR2 PIRHN nLight AIR enabled luminaire for motion sensing,
photocell and wireless communication.
Motion and ambient light sensing with group
response. Scheduled dimming with motion sensor
over-ride when wirelessly connected to the nLight
Eclypse.
nLight Air rSBG nLight AIR sensors can be programmed and commissioned
from the ground using the ClAIRity Pro app. Cannot be used
with other controls options that need the 0-10V leads.
BL30 or BL50 Integrated bi-level device that allows a second control
circuit to switch all light engines to either 30% or 50%
light output
BLC device provides input to 0-10V dimming leads on
all drivers providing either 100% or dimmed (30% or
50%) control by a secondary circuit
BLC UVOLT1 BLC device is powered off the 0-10V dimming leads, thus
can be used with any input voltage from 120 to 480V
Lumen Ambient Temperature (LAT) Multipliers
Use these factors to determine relative lumen output for average ambient temperatures
from 0-40°C (32-104°F).
Ambient Lumen Multiplier
0°C 32°F 1.04
5°C 41°F 1.04
10°C 50°F 1.03
15°C 50°F 1.02
20°C 68°F 1.01
25°C 77°C 1.00
30°C 86°F 0.99
35°C 95°F 0.98
40°C 104°F 0.97
Projected LED Lumen Maintenance
Data references the extrapolated performance projections for the platforms noted in a 25°C
ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per
IESNA TM-21-11).
To calculate LLF , use the lumen maintenance factor that corresponds to the desired number of
operating hours below. For other lumen maintenance values, contact factory.
Operating Hours Lumen Maintenance Factor
0 1.00
25,000 0.94
50,000 0.89
100,000 0.80
70 CRI 80CRI 90CRI
Lumen Multiplier Availability Lumen Multiplier Availability Lumen Multiplier Availability
5000K 102% Standard 92% Extended lead-time 71% (see note)
4000K 100% Standard 92% Extended lead-time 67% (see note)
3500K 100% (see note) 90% Extended lead-time 63% (see note)
3000K 96% Standard 87% Extended lead-time 61% (see note)
2700K 94% (see note) 85% Extended lead-time 57% (see note)
LED Color Temperature / Color Rendering Multipliers
Note: Some LED types are available as per special request. Contact Technical Support for more information.
*Note: Calculated values are based on original performance
package data. When calculating new values for given FAO position,
use published values for each package based on input watts and
lumens by optic type.
FAO Position % Wattage % Lumen Output
8 100% 100%
7 93% 95%
6 80% 85%
5 66% 73%
4 54% 61%
3 41% 49%
2 29% 36%
1 15% 20%
FAO Dimming Settings
Page 140 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 5 of 9
COMMERCIAL OUTDOOR
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79.
Contact factory for performance data on any configurations not shown here.
Forward Optics
Performance
Package System Watts LED Count Drive
Current (mA) Distribution Type
30K 40K 50K
(3000K, 70 CRI) (4000K, 70 CRI) (5000K, 70 CRI)
Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW
P1 33W 20 530
T1S 4,906 1 0 1 148 5,113 1 0 1 154 5,213 1 0 1 157
T2M 4,545 1 0 2 137 4,736 1 0 2 143 4,829 1 0 2 145
T3M 4,597 1 0 2 138 4,791 1 0 2 144 4,885 1 0 2 147
T3LG 4,107 1 0 1 124 4,280 1 0 1 129 4,363 1 0 1 131
T4M 4,666 1 0 2 141 4,863 1 0 2 146 4,957 1 0 2 149
T4LG 4,244 1 0 1 128 4,423 1 0 1 133 4,509 1 0 1 136
TFTM 4,698 1 0 2 141 4,896 1 0 2 147 4,992 1 0 2 150
T5M 4,801 3 0 1 145 5,003 3 0 1 151 5,101 3 0 1 154
T5W 4,878 3 0 1 147 5,084 3 0 2 153 5,183 3 0 2 156
T5LG 4,814 2 0 1 145 5,018 2 0 1 151 5,115 2 0 1 154
BLC3 3,344 0 0 1 101 3,485 0 0 1 105 3,553 0 0 1 107
BLC4 3,454 0 0 2 104 3,599 0 0 2 108 3,670 0 0 2 111
RCCO 3,374 0 0 1 102 3,517 0 0 1 106 3,585 0 0 1 108
LCCO 3,374 0 0 1 102 3,517 0 0 1 106 3,585 0 0 1 108
AFR 4,906 1 0 1 148 5,113 1 0 1 154 5,213 1 0 1 157
P2 45W 20 700
T1S 6,328 1 0 1 140 6,595 1 0 1 146 6,724 1 0 1 149
T2M 5,862 1 0 2 130 6,109 1 0 2 135 6,228 1 0 2 138
T3M 5,930 1 0 3 131 6,180 1 0 3 137 6,301 1 0 3 140
T3LG 5,297 1 0 1 117 5,521 1 0 1 122 5,628 1 0 1 125
T4M 6,018 1 0 3 133 6,272 1 0 3 139 6,395 1 0 3 142
T4LG 5,474 1 0 1 121 5,705 1 0 1 126 5,816 1 0 1 129
TFTM 6,060 1 0 3 134 6,316 1 0 3 140 6,439 1 0 3 143
T5M 6,192 3 0 1 137 6,453 3 0 2 143 6,579 3 0 2 146
T5W 6,293 3 0 2 139 6,558 3 0 2 145 6,686 3 0 2 148
T5LG 6,210 2 0 1 138 6,472 3 0 1 143 6,598 3 0 1 146
BLC3 4,313 0 0 2 96 4,495 0 0 2 100 4,583 0 0 2 102
BLC4 4,455 0 0 2 99 4,643 0 0 2 103 4,733 0 0 2 105
RCCO 4,352 0 0 2 96 4,536 0 0 2 100 4,624 0 0 2 102
LCCO 4,352 0 0 2 96 4,536 0 0 2 100 4,624 0 0 2 102
AFR 6,328 1 0 1 140 6,595 1 0 1 146 6,724 1 0 1 149
P3 69W 20 1050
T1S 9,006 1 0 2 131 9,386 1 0 2 136 9,569 1 0 2 139
T2M 8,343 2 0 3 121 8,694 2 0 3 126 8,864 2 0 3 129
T3M 8,439 2 0 3 122 8,795 2 0 3 128 8,967 2 0 3 130
T3LG 7,539 1 0 2 109 7,857 1 0 2 114 8,010 1 0 2 116
T4M 8,565 2 0 3 124 8,926 2 0 3 129 9,100 2 0 3 132
T4LG 7,790 1 0 2 113 8,119 1 0 2 118 8,277 1 0 2 120
TFTM 8,624 1 0 3 125 8,988 1 0 3 130 9,163 2 0 3 133
T5M 8,812 3 0 2 128 9,184 4 0 2 133 9,363 4 0 2 136
T5W 8,955 4 0 2 130 9,333 4 0 2 135 9,515 4 0 2 138
T5LG 8,838 3 0 1 128 9,211 3 0 1 134 9,390 3 0 1 136
BLC3 6,139 0 0 2 89 6,398 0 0 2 93 6,522 0 0 2 95
BLC4 6,340 0 0 3 92 6,607 0 0 3 96 6,736 0 0 3 98
RCCO 6,194 1 0 2 90 6,455 1 0 2 94 6,581 1 0 2 95
LCCO 6,194 1 0 2 90 6,455 1 0 2 94 6,581 1 0 2 95
AFR 9,006 1 0 2 131 9,386 1 0 2 136 9,569 1 0 2 139
P4 93W 20 1400
T1S 11,396 1 0 2 122 11,877 1 0 2 128 12,109 2 0 2 130
T2M 10,557 2 0 3 113 11,003 2 0 3 118 11,217 2 0 3 121
T3M 10,680 2 0 3 115 11,130 2 0 3 120 11,347 2 0 3 122
T3LG 9,540 1 0 2 103 9,942 1 0 2 107 10,136 1 0 2 109
T4M 10,839 2 0 3 117 11,296 2 0 3 121 11,516 2 0 4 124
T4LG 9,858 1 0 2 106 10,274 1 0 2 110 10,474 1 0 2 113
TFTM 10,914 2 0 3 117 11,374 2 0 3 122 11,596 2 0 3 125
T5M 11,152 4 0 2 120 11,622 4 0 2 125 11,849 4 0 2 127
T5W 11,332 4 0 3 122 11,811 4 0 3 127 12,041 4 0 3 129
T5LG 11,184 3 0 1 120 11,656 3 0 2 125 11,883 3 0 2 128
BLC3 7,768 0 0 2 83 8,096 0 0 2 87 8,254 0 0 2 89
BLC4 8,023 0 0 3 86 8,362 0 0 3 90 8,524 0 0 3 92
RCCO 7,838 1 0 2 84 8,169 1 0 2 88 8,328 1 0 2 90
LCCO 7,838 1 0 2 84 8,169 1 0 2 88 8,328 1 0 2 90
AFR 11,396 1 0 2 122 11,877 1 0 2 128 12,109 2 0 2 130
Performance Data
Lumen Output
Page 141 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 6 of 9
COMMERCIAL OUTDOOR
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79.
Contact factory for performance data on any configurations not shown here.
Forward Optics
Performance
Package System Watts LED Count Drive
Current (mA) Distribution Type
30K 40K 50K
(3000K, 70 CRI) (4000K, 70 CRI) (5000K, 70 CRI)
Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW
P5 90W 40 700
T1S 12,380 2 0 2 137 12,902 2 0 2 143 13,154 2 0 2 146
T2M 11,468 2 0 3 127 11,952 2 0 3 133 12,185 2 0 3 135
T3M 11,601 2 0 3 129 12,091 2 0 3 134 12,326 2 0 4 137
T3LG 10,363 2 0 2 115 10,800 2 0 2 120 11,011 2 0 2 122
T4M 11,774 2 0 4 131 12,271 2 0 4 136 12,510 2 0 4 139
T4LG 10,709 1 0 2 119 11,160 2 0 2 124 11,378 2 0 2 126
TFTM 11,856 2 0 3 132 12,356 2 0 4 137 12,596 2 0 4 140
T5M 12,114 4 0 2 134 12,625 4 0 2 140 12,871 4 0 2 143
T5W 12,310 4 0 3 137 12,830 4 0 3 142 13,080 4 0 3 145
T5LG 12,149 3 0 2 135 12,662 3 0 2 141 12,908 3 0 2 143
BLC3 8,438 0 0 2 94 8,794 0 0 2 98 8,966 0 0 2 99
BLC4 8,715 0 0 3 97 9,083 0 0 3 101 9,260 0 0 3 103
RCCO 8,515 1 0 2 94 8,874 1 0 2 98 9,047 1 0 2 100
LCCO 8,515 1 0 2 94 8,874 1 0 2 98 9,047 1 0 2 100
AFR 12,380 2 0 2 137 12,902 2 0 2 143 13,154 2 0 2 146
P6 137W 40 1050
T1S 17,545 2 0 3 128 18,285 2 0 3 133 18,642 2 0 3 136
T2M 16,253 3 0 4 119 16,939 3 0 4 124 17,269 3 0 4 126
T3M 16,442 2 0 4 120 17,135 3 0 4 125 17,469 3 0 4 128
T3LG 14,687 2 0 2 107 15,306 2 0 2 112 15,605 2 0 2 114
T4M 16,687 2 0 4 122 17,391 3 0 5 127 17,730 3 0 5 129
T4LG 15,177 2 0 2 111 15,817 2 0 2 115 16,125 2 0 2 118
TFTM 16,802 2 0 4 123 17,511 2 0 4 128 17,852 2 0 5 130
T5M 17,168 4 0 2 125 17,893 5 0 3 131 18,241 5 0 3 133
T5W 17,447 5 0 3 127 18,183 5 0 3 133 18,537 5 0 3 135
T5LG 17,218 4 0 2 126 17,944 4 0 2 131 18,294 4 0 2 134
BLC3 11,959 0 0 3 87 12,464 0 0 3 91 12,707 0 0 3 93
BLC4 12,352 0 0 4 90 12,873 0 0 4 94 13,124 0 0 4 96
RCCO 12,067 1 0 3 88 12,576 1 0 3 92 12,821 1 0 3 94
LCCO 12,067 1 0 3 88 12,576 1 0 3 92 12,821 1 0 3 94
AFR 17,545 2 0 3 128 18,285 2 0 3 133 18,642 2 0 3 136
P7 171W 40 1300
T1S 20,806 2 0 3 122 21,683 2 0 3 127 22,106 2 0 3 129
T2M 19,273 3 0 4 113 20,086 3 0 4 118 20,478 3 0 4 120
T3M 19,497 3 0 5 114 20,319 3 0 5 119 20,715 3 0 5 121
T3LG 17,416 2 0 2 102 18,151 2 0 2 106 18,504 2 0 2 108
T4M 19,787 3 0 5 116 20,622 3 0 5 121 21,024 3 0 5 123
T4LG 17,997 2 0 2 105 18,756 2 0 2 110 19,121 2 0 2 112
TFTM 19,924 3 0 5 117 20,765 3 0 5 122 21,170 3 0 5 124
T5M 20,359 5 0 3 119 21,217 5 0 3 124 21,631 5 0 3 127
T5W 20,689 5 0 3 121 21,561 5 0 3 126 21,982 5 0 3 129
T5LG 20,418 4 0 2 120 21,279 4 0 2 125 21,694 4 0 2 127
BLC3 14,182 0 0 3 83 14,780 0 0 3 87 15,068 0 0 3 88
BLC4 14,647 0 0 4 86 15,265 0 0 4 89 15,562 0 0 4 91
RCCO 14,309 1 0 3 84 14,913 1 0 3 87 15,204 1 0 3 89
LCCO 14,309 1 0 3 84 14,913 1 0 3 87 15,204 1 0 3 89
AFR 20,806 2 0 3 122 21,683 2 0 3 127 22,106 2 0 3 129
Lumen Output
Performance Data
Page 142 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 7 of 9
COMMERCIAL OUTDOOR
Performance Data
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79.
Contact factory for performance data on any configurations not shown here.
Rotated Optics
Performance
Package System Watts LED Count Drive
Current (mA) Distribution Type
30K 40K 50K
(3000K, 70 CRI) (4000K, 70 CRI) (5000K, 70 CRI)
Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW
P10 51W 30 530
T1S 7,399 3 0 3 145 7,711 3 0 3 151 7,862 3 0 3 154
T2M 6,854 3 0 3 135 7,144 3 0 3 140 7,283 3 0 3 143
T3M 6,933 3 0 3 136 7,225 3 0 3 142 7,366 3 0 3 145
T3LG 6,194 2 0 2 122 6,455 2 0 2 127 6,581 2 0 2 129
T4M 7,036 3 0 3 138 7,333 3 0 3 144 7,476 3 0 3 147
T4LG 6,399 2 0 2 126 6,669 2 0 2 131 6,799 2 0 2 134
TFTM 7,086 3 0 3 139 7,385 3 0 3 145 7,529 3 0 3 148
T5M 7,239 3 0 2 142 7,545 3 0 2 148 7,692 3 0 2 151
T5W 7,357 3 0 2 145 7,667 3 0 2 151 7,816 4 0 2 154
T5LG 7,260 3 0 1 143 7,567 3 0 1 149 7,714 3 0 1 152
BLC3 5,043 3 0 3 99 5,256 3 0 3 103 5,358 3 0 3 105
BLC4 5,208 3 0 3 102 5,428 3 0 3 107 5,534 3 0 3 109
RCCO 5,089 0 0 2 100 5,303 0 0 2 104 5,407 0 0 2 106
LCCO 5,089 0 0 2 100 5,303 0 0 2 104 5,407 0 0 2 106
AFR 7,399 3 0 3 145 7,711 3 0 3 151 7,862 3 0 3 154
P11 68W 30 700
T1S 9,358 3 0 3 138 9,753 3 0 3 143 9,943 3 0 3 146
T2M 8,669 3 0 3 127 9,034 3 0 3 133 9,211 3 0 3 135
T3M 8,768 3 0 3 129 9,138 3 0 3 134 9,316 3 0 3 137
T3LG 7,833 3 0 3 115 8,164 3 0 3 120 8,323 3 0 3 122
T4M 8,899 3 0 3 131 9,274 3 0 3 136 9,455 3 0 3 139
T4LG 8,093 3 0 3 119 8,435 3 0 3 124 8,599 3 0 3 126
TFTM 8,962 3 0 3 132 9,340 3 0 3 137 9,522 3 0 3 140
T5M 9,156 4 0 2 135 9,542 4 0 2 140 9,728 4 0 2 143
T5W 9,304 4 0 2 137 9,696 4 0 2 143 9,885 4 0 2 145
T5LG 9,182 3 0 1 135 9,569 3 0 1 141 9,756 3 0 1 143
BLC3 6,378 3 0 3 94 6,647 3 0 3 98 6,777 3 0 3 100
BLC4 6,587 3 0 3 97 6,865 3 0 3 101 6,999 3 0 3 103
RCCO 6,436 0 0 2 95 6,707 0 0 2 99 6,838 0 0 2 101
LCCO 6,436 0 0 2 95 6,707 0 0 2 99 6,838 0 0 2 101
AFR 9,358 3 0 3 138 9,753 3 0 3 143 9,943 3 0 3 146
P12 103W 30 1050
T1S 13,247 3 0 3 128 13,806 3 0 3 134 14,075 3 0 3 136
T2M 12,271 4 0 4 119 12,789 4 0 4 124 13,038 4 0 4 126
T3M 12,412 4 0 4 120 12,935 4 0 4 125 13,187 4 0 4 128
T3LG 11,089 3 0 3 107 11,556 3 0 3 112 11,782 3 0 3 114
T4M 12,597 4 0 4 122 13,128 4 0 4 127 13,384 4 0 4 129
T4LG 11,457 3 0 3 111 11,940 3 0 3 116 12,173 3 0 3 118
TFTM 12,686 4 0 4 123 13,221 4 0 4 128 13,479 4 0 4 130
T5M 12,960 4 0 2 125 13,507 4 0 2 131 13,770 4 0 2 133
T5W 13,170 4 0 3 127 13,726 4 0 3 133 13,994 4 0 3 135
T5LG 12,998 3 0 2 126 13,546 3 0 2 131 13,810 3 0 2 134
BLC3 9,029 3 0 3 87 9,409 3 0 3 91 9,593 3 0 3 93
BLC4 9,324 4 0 4 90 9,718 4 0 4 94 9,907 4 0 4 96
RCCO 9,110 1 0 2 88 9,495 1 0 2 92 9,680 1 0 2 94
LCCO 9,110 1 0 2 88 9,494 1 0 2 92 9,680 1 0 2 94
AFR 13,247 3 0 3 128 13,806 3 0 3 134 14,075 3 0 3 136
P13 129W 30 1300
T1S 15,704 3 0 3 122 16,366 3 0 3 127 16,685 4 0 4 130
T2M 14,547 4 0 4 113 15,161 4 0 4 118 15,457 4 0 4 120
T3M 14,714 4 0 4 114 15,335 4 0 4 119 15,634 4 0 4 121
T3LG 13,145 3 0 3 102 13,700 3 0 3 106 13,967 3 0 3 108
T4M 14,933 4 0 4 116 15,563 4 0 4 121 15,867 4 0 4 123
T4LG 13,582 3 0 3 105 14,155 3 0 3 110 14,431 3 0 3 112
TFTM 15,039 4 0 4 117 15,673 4 0 4 122 15,979 4 0 4 124
T5M 15,364 4 0 2 119 16,013 4 0 2 124 16,325 4 0 2 127
T5W 15,613 5 0 3 121 16,272 5 0 3 126 16,589 5 0 3 129
T5LG 15,409 3 0 2 120 16,059 3 0 2 125 16,372 4 0 2 127
BLC3 10,703 4 0 4 83 11,155 4 0 4 87 11,372 4 0 4 88
BLC4 11,054 4 0 4 86 11,520 4 0 4 89 11,745 4 0 4 91
RCCO 10,800 1 0 2 84 11,256 1 0 2 87 11,475 1 0 3 89
LCCO 10,800 1 0 2 84 11,255 1 0 2 87 11,475 1 0 3 89
AFR 15,704 3 0 3 122 16,366 3 0 3 127 16,685 4 0 4 130
Lumen Output
Page 143 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 8 of 9
COMMERCIAL OUTDOOR
27.70"
2.26"
14.06"
7.80"
28.00"
2.26"
14.06"
8.90"
32.17"
2.26"
14.06"
7.59"
DSX0 with RPA, RPA5, SPA5, SPA8N mount
Weight: 25 lbs
Dimensions
2.41"
3.16"
SPA (STANDARD ARM)
2.41"
3.16"
RPA
2.41"
3.16"
SPA8N
4.25"
RPA5
4.25"
SPA5
DSX0 with WBA mount
Weight: 27 lb
DSX0 with MA mount
Weight: 28 lbs
Page 144 of 161
1 Acuity Way • Decatur, Georgia 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
DSX0-LED
Rev. 08/28/25
Page 9 of 9
COMMERCIAL OUTDOOR
nLight Control - Sensor Coverage and Settings
nLight Sensor Coverage Pattern
NLTAIR2 PIRHN
Top Side
FEATURES & SPECIFICATIONS
INTENDED USE
The sleek design of the D-Series Size 0 reflects the embedded high performance
LED technology. It is ideal for many commercial and municipal applications, such as
parking lots, plazas, campuses, and pedestrian areas.
CONSTRUCTION
Single-piece die-cast aluminum housing has integral heat sink fins to optimize
thermal management through conductive and convective cooling. Modular design
allows for ease of maintenance and future light engine upgrades. The LED driver is
mounted in direct contact with the casting to promote low operating temperature
and long life. Housing driver compartment is completely sealed against moisture
and environmental contaminants (IP66). Vibration rated per ANSI C136.31 for 3G.
Low EPA (0.44 ft2) for optimized pole wind loading.
FINISH
Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset
powder coat finish that provides superior resistance to corrosion and weathering.
A tightly controlled multi-stage process ensures a minimum 3 mils thickness for
a finish that can withstand extreme climate changes without cracking or peeling.
Available in both textured and non-textured finishes.
COASTAL CONSTRUCTION (CCE)
Optional corrosion resistant construction is engineered with added corrosion
protection in materials and/or pre-treatment of base material under super
durable paint. Provides additional corrosion protection for applications near
coastal areas. Finish is salt spray tested to over 5,000 hours per ASTM B117 with
scribe rating of 10. Additional lead-times may apply.
OPTICS
Precision-molded proprietary silicone lenses are engineered for superior area
lighting distribution, uniformity, and pole spacing. Light engines are available
in 3000 K, 4000 K or 5000 K (70 CRI) configurations. 80CRI configurations are
also available. The D-Series Size 0 has zero uplight and qualifies as a Nighttime
Friendly™ product, meaning it is consistent with the LEED® and Green Globes™
criteria for eliminating wasteful uplight.
ELECTRICAL
Light engine(s) configurations consist of high-efficacy LEDs mounted to metal-
core circuit boards to maximize heat dissipation and promote long life (up to
L80/100,000 hours at 25°C). Class 1 electronic drivers are designed to have a
power factor >90%, THD <20%, and an expected life of 100,000 hours with <1%
failure rate. Easily serviceable 10kV surge protection device meets a minimum
Category C Low operation (per ANSI/IEEE C62.41.2).
STANDARD CONTROLS
The DSX0 LED area luminaire has a number of control options. DSX Size 0, comes
standard with 0-10V dimming driver. Dusk to dawn controls can be utilized via
optional NEMA twist-lock photocell receptacles. PIR integrated motion sensor
with on-board photocell feature field-adjustable programing and are suitable for
mounting heights up to 40 feet. Control option BL features a bi-level device that
allows a second control circuit to switch all light engines to either 30% or 50%
light output.
nLIGHT AIR CONTROLS
The DSX0 LED area luminaire is also available with nLight® AIR for the ultimate
in wireless control. This powerful controls platform provides out-of-the-box basic
motion sensing and photocontrol functionality and is suitable for mounting
heights up to 40 feet. Once commissioned using a smartphone and the easy-to-
use CLAIRITY app, nLight AIR equipped luminaries can be grouped, resulting
in motion sensor and photocell group response without the need for additional
equipment. Scheduled dimming with motion sensor over-ride can be achieved
when used with the nLight Eclypse. Additional information about nLight Air can
be found here.
INSTALLATION
Integral mounting arm allows for fast mounting using Lithonia standard #8 drilling
and accommodates pole drilling's from 2.41 to 3.12" on center. The standard
“SPA” option for square poles and the “RPA” option for round poles use the
#8 drilling. For #5 pole drillings, use SPA5 or RPA5. Additional mountings are
available including a wall bracket (WBA) and mast arm (MA) option that allows
luminaire attachment to a 2 3/8” horizontal mast arm.
LISTINGS
UL listed to meet U.S. and Canadian standards. UL Listed for wet locations. Light
engines are IP66 rated; luminaire is IP66 rated. Rated for -40°C minimum ambient.
DesignLights Consortium® (DLC) Premium qualified product and DLC qualified
product. Not all versions of this product may be DLC Premium qualified or DLC
qualified. Please check the DLC Qualified Products List at www.designlights.org/
QPL to confirm which versions are qualified.
International Dark-Sky Association (IDA) Fixture Seal of Approval (FSA) is available
for all products on this page utilizing 3000K color temperature only.
GOVERNMENT PROCUREMENT
BAA – Buy America(n) Act: Product with the BAA option qualifies as a domestic
end product under the Buy American Act as implemented in the FAR and
DFARS. Product with the BAA option also qualifies as manufactured in the United
States under DOT Buy America regulations.
BABA – Build America Buy America: Product with the BAA option also qualifies
as produced in the United States under the definitions of the Build America, Buy
America Act.
Please refer to www.acuitybrands.com/buy-american for additional information.
WARRANTY
5-year limited warranty. This is the only warranty provided and no other
statements in this specification sheet create any warranty of any kind. All other
express and implied warranties are disclaimed. Complete warranty terms located
at: www.acuitybrands.com/support/warranty/terms-and-conditions
Note: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.
Page 145 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2021-2026 Acuity Brands Lighting, Inc. All rights reserved.
CONTRACTOR SELECT HGX LED
Rev. 09/09/26
COMMERCIAL OUTDOOR
HGX
A complete security
floodlighting solution
Catalog
Number
Notes
Type
Hit the Tab key or mouse over the page to see all interactive elements.
Introduction
The HomeGuard LED family of security flood lights, built
with rugged die cast aluminum construction, are long
lasting, energy efficient solutions for replacing incandescent
PAR lamp fixtures. Mounted under an eave or on a wall,
these luminaires provide reliable security lighting in
residential and commercial applications (PIR unit is wall
mount only).The HGX family has seven configurations
both in bronze and white. Featuring a low cost version for
switched circuits and fully featured products that include the
following options: an integral photocell for that automatic
dusk-to-dawn operation, adjustable lumen output, color
temperature switchability, and a PIR motion sensor in a wall
sconce SKU. With tool-less easy-to-aim lamps, HGX installs
quickly, and delivers a lumen range from 1700 to 4100. The
HGX family provide great flexibility and versatility.
TM
CAN BE USED TO
COMPL Y WITH 2019
HIGH EFFICACY LED LIGHT
SOURCE REQUIREMENTS
Luminaire Width (W) Length (L) Height (H) Lamp head
dia (A)
Back plate
dia (B)
Back plate
thickness (C) Weight
HGX 2RH 4.41"
(11.2cm)
7.56"
(19.2cm)
4.25"
(10.8cm)
2.4"
(6.1cm)
4.25"
(10.8cm)
1.38"
(3.5cm)
1.15 lbs
(0.52 kg)
HGX 3RH 5.12"
(13cm)
7.72"
(19.6cm)
4.53"
(11.5cm)
2.4"
(6.1cm)
4.53"
(11.51cm)
2.13"
(5.4cm)
1.77 lbs
(0.8kg)
HGX 2SH 4.53"
(11.5cm)
7.56"
(19.2cm)
4.33"
(11cm)
2.40"
(6.1cm)
4.33"
(11cm)
1.54"
(3.9cm)
1.31 lbs
(0.6kg)
HGX 2RH PIR 4.96"
(12.6cm)
7.52"
(19.1cm)
4.53"
(11.5cm)
2.40"
(6.1cm)
4.53"
(11.5cm)
1.89"
(4.8cm)
1.37lbs
(0.62 kg)
HGX 2RH ALO 4.53"
(11.51cm)
7.56"
(19.2cm)
4.33"
(11cm)
2.40"
(6.1cm)
4.33"
(11cm)
1.54"
(3.9cm)
1.31lbs
(0.6kg)
HGX 2RH MO 4.7"
(11.9cm)
7.56"
(19.2cm)
6.14"
(15.6cm)
2.40"
(6.1cm)
1.38"
(3.5cm)
4.25"
(10.8cm)
1.38 lbs
(0.63kg)
HGX 3RH MO 5.60"
(14.2cm)
8.90"
(22.5cm)
6.60"
(16.7cm)
2.40"
(6.1cm)
4.53"
(11.5cm)
2.05"
(5.2cm)
1.92 lbs
(0.87kg)
L W
H
L W
H
L W
H
L W
H
L W
H
HGX LED 2RH ALO SWW2 120 PE DDB M2 HGX LED 3RH 40K 120 MO DDB M2
HGX LED 2RH ALO SWW2 120 PIR DDB M2
*Wall mount only
HGX LED 2RH 40K 120 MO DDB M2 HGX LED 3RH ALO SWW2 120 PE WH M2
HGX LED 2RH & HGX 2RH ALO HGX 2SH
HGX LED 3RH
HGX 2RH MO
HGX 2RH PIR
HGX LED 3RH MO
Page 146 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2021-2026 Acuity Brands Lighting, Inc. All rights reserved.
CONTRACTOR SELECT HGX LED
Rev. 09/09/26
COMMERCIAL OUTDOOR
*PIR unit is wet location rated and is to be used for wall mount applications
Ordering Information EXAMPLE: HGX LED 3RH ALO SWW2 120 PE DDB
Full photometric data report available within 2 weeks from request. Contact Acuity tech support.Photometric Diagrams
LEGEND
0.1 fc
0.2 fc
0.5 fc
1.0 fc
Visual - Template Tool
These lighting calculation results are for general informational purposes only and are provided without warranty as to accuracy, completeness, reliability or
otherwise. Results are based on user provided data and data provided from publicly available sources; actual field conditions may affect calculated output. Visit
www.Visual-3D.com .
Design Information
Project
Description
Wednesday, April 21, 2021
Name
Company
Phone
Email
[ A ] - HGX LED 2RH ALO SWW2 120 PE
Manufacturer Lithonia Lighting Configuration Single
Lamp Lumens 2963 Orientation Single
Lamp Quantity 1 Mounting Height 12
Light Loss Factor 1 Arm Length 1
Input Power 24.6 Tilt 45
Max Illuminance 7 Area > 0.5fc 1013
Homeguard ordering nomenclature and stocked configurations
Nomenclature UPC CI Code Features
HGX LED 2RH 40K 120 DDB 00194995254156 *271FE9
HGX LED 2RH 40K 120 WH 00194995254170 *271FEE
HGX LED 2RH ALO 40K 120 PE DDB 00194995254200 *271FEF
HGX LED 2RH ALO 40K 120 PE WH 00194995254194 *271FEH
HGX LED 2RH ALO SWW2 120 PE DDB 00194995254255 *271FEP
HGX LED 2RH ALO SWW2 120 PE WH 00194995254316 *271FEV
HGX LED 2SH ALO SWW2 120 PE DDB 00194995255214 *271FJ3
HGX LED 2SH ALO SWW2 120 PE WH 00194995255207 *271FJ4
HGX LED 3RH ALO SWW2 120 PE DDB 00194995255160 *271FHW
HGX LED 3RH ALO SWW2 120 PE WH 00194995255139 *271FJ0
HGX LED 2RH ALO SWW2 120 PIR DDB* 00194995254330 *271FEX
HGX LED 2RH ALO SWW2 120 PIR WH* 00194995255092 *271FHR
HGX LED 2RH 40K 120 MO DDB M2 00196182114717 *2754KP
HGX LED 2RH 40K 120 MO WH M2 00196182114700 *2754KR
HGX LED 3RH 40K 120 MO DDB M2 00199871048904 *295S4V
Visual - Template Tool
These lighting calculation results are for general informational purposes only and are provided without warranty as to accuracy, completeness, reliability or
otherwise. Results are based on user provided data and data provided from publicly available sources; actual field conditions may affect calculated output. Visit
www.Visual-3D.com .
Design Information
Project
Description
Wednesday, April 21, 2021
Name
Company
Phone
Email
[ B ] - HGX LED 2RH ALO SWW2 120 PIR
Manufacturer Lithonia Lighting Configuration Single
Lamp Lumens 2574 Orientation Single
Lamp Quantity 1 Mounting Height 12
Light Loss Factor 1 Arm Length 1
Input Power 26.2 Tilt 45
Max Illuminance 6 Area > 0.5fc 923
Visual - Template Tool
These lighting calculation results are for general informational purposes only and are provided without warranty as to accuracy, completeness, reliability or
otherwise. Results are based on user provided data and data provided from publicly available sources; actual field conditions may affect calculated output. Visit
www.Visual-3D.com .
Design Information
Project
Description
Wednesday, April 21, 2021
Name
Company
Phone
Email
[ C ] - HGX LED 3RH ALO SWW2 120 PE
Manufacturer Lithonia Lighting Configuration Single
Lamp Lumens 4397 Orientation Single
Lamp Quantity 1 Mounting Height 12
Light Loss Factor 1 Arm Length 1
Input Power 35.1 Tilt 45
Max Illuminance 11 Area > 0.5fc 1305
Adjustable Lumen Output
ALO
Dusk-to-Dawn Operation
PE
Switchable CCT SWW2
(3000K/4000K/5000K)
Motion Sensor Capable
MO
Page 147 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2021-2026 Acuity Brands Lighting, Inc. All rights reserved.
CONTRACTOR SELECT HGX LED
Rev. 09/09/26
COMMERCIAL OUTDOOR
HomeGuard LED Stocked Configurations
Low Medium High
Nomenclature Lumens Wattage CRI Lumens Wattage CRI Lumens Wattage CRI Options
HGX LED 2RH 40K 120 DDB
2750 25 80
HGX LED 2RH 40K 120 WH
HGX LED 2RH ALO 40K 120 PE DDB
1750 15 80 2750 25 80
HGX LED 2RH ALO 40K 120 PE WH
HGX LED 2RH ALO SWW2 120 PE DDB
1800 15 80 2750 25 80
HGX LED 2RH ALO SWW2 120 PE WH
HGX LED 2SH ALO SWW2 120 PE DDB
1700 15 80 2700 25 80
HGX LED 2SH ALO SWW2 120 PE WH
HGX LED 3RH ALO SWW2 120 PE DDB
1750 15 80 2750 25 80 4100 36 80
HGX LED 3RH ALO SWW2 120 PE WH
HGX LED 2RH ALO SWW2 120 PIR DDB
2150 21 80 2600 26 80
HGX LED 2RH ALO SWW2 120 PIR WH
HGX LED 2RH 40K 120 MO DDB M2 2750 25 80
HGX LED 2RH 40K 120 MO WH M2 2750 25 80
HGX LED 3RH 40K 120 MO DDB M2 4165 38 80
Adjustable Lumen Output
ALO
Dusk-to-Dawn Operation
PE
Switchable CCT SWW2
(3000K/4000K/5000K)
Motion Sensor Capable
MO
HGX motion security dusk-to-dawn floodlight. Full-
range dual motion sensor with 200° sensors that
eliminate common blind spots
Page 148 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2021-2026 Acuity Brands Lighting, Inc. All rights reserved.
CONTRACTOR SELECT HGX LED
Rev. 09/09/26
COMMERCIAL OUTDOOR
FEATURES & SPECIFICATIONS
INTENDED USE
HGX security floods are ideal for an energy efficient replacement for two lamp 200W
incandescent security lights. The HGX LED provides over 50K hours of maintenance-free
general illumination for outdoor applications. HGX with its 2RH/3RH/2SH head with PE
options prevents daylight operation and saves on energy costs. Further with adjustable
light output and color tuning technology built into HGX, it provides great flexibility for
mounting and color selection. Ideal for entrances, walkways, corridors, yards, driveways
and patios.
CONSTRUCTION
Cast-aluminum housing with dark bronze or white polyester powder paint for lasting
durability. Photocell sensitivity is adjustable. LED lamp heads are thermally isolated
from the driver that is located in the rear housing, promoting a long service life. Lenses
are sealed to prolong service life. LEDs maintain 70% of light output at 50,000 hours of
service life.
ELECTRICAL
HGX family comes in six configurations from low cost version which is on switched circuit
to a fully featured product which has adjustable lumens, photocell, color and motion.
The HGX is rated for outdoor installations .The 2 RH versions consume 25W and 3RH
version consumes 36W and 38W power, 120V input 60 HZ driver. LED's with min. 80 CRI
provide great quality of light and rendering. HGX with PIR option (motion sensor) has
up to 180 degree motion detection angle, range of up to 40' at 18C/65 F and has three
modes – test, 1 or five minutes on time after motion is detected. Motion sensitivity and
daylight sensing is adjustable. Wall Sconce PIR unit is recommended for wall mount only.
ADJUSTABLE FEATURES
Adjustable light output – select HGX products include adjustable lumen output –
2 settings on 2 head versions & 3 settings on 3 RH version. The lumens can be adjusted
by rotation of dial. Use the same product to mount on various mounting heights by
increasing or decreasing the light output. Color Tuning – Color temperature of the lamp
heads can be switched with rotation of dial from warm to cool to daylight. Adjustable
photocell – the sensitivity of the PE can be adjusted. The dial can be turned off to make
the light turn on during day time, or have it only as dusk-to-dawn operation.
INSTALLATION
Mounts to a recessed junction box on wall or ceiling. Crossbar and hardware provided.
Wet location listed for mounting 4 feet above ground. Tool-less adjustable heads allow
for precise aiming. Mounts to 4x4 round, square or octagonal recessed junction box.
LISTINGS
UL/cUL listed Listed to U.S. and Canadian safety standards for wet locations. Tested in
accordance with IESNA LM-79 and LM-80 standards. All units are IP65 except HGX PIR
which is wet location. HGX is rated for use in ambient conditions ranging from -40° C to
40° C.
WARRANTY
Five-year limited warranty. This is the only warranty provided and no other statements
in this specification sheet create any warranty of any kind. All other express and implied
warranties are disclaimed. Complete warranty terms located at:
www.acuitybrands.com/support/warranty/terms-and-conditions
Note: Actual performance may differ as a result of end-user environment and
application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
The product images shown are for illustration purposes only and may not be an exact
representation of the product.
Specifications subject to change without notice.
Page 149 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
COMMERCIAL OUTDOOR Rev. 12/08/25
RAD1 LED
Radean Arm Mount
LED Area Luminaire
Specifications
Catalog
Number
Notes
Type
Introduction
The RADEAN arm mount luminaire is the
perfect choice for pedestrian applications
where daytime aesthetics and visual comfort
are needed. Adding architectural flair to any
space, the RADEAN’s low-profile shape and
smooth curves blend in while adding a touch of
elegance.
Perfect for campuses, parks, pedestrian malls,
courtyards and pathways, the RADEAN arm
mount is the Architect’s choice to provide
beautiful aesthetics both day and night.
Hit the Tab key or mouse over the page to see all interactive elements.
L1
3.7”H
L2
W
RAD1 LED
Series Performance package Color temperature Distribution Voltage Mounting
RAD1 LED P1 3,000 Lumens
P2 5,000 Lumens
P3 7 ,000 Lumens
P4 11,000 Lumens
P5 16,000 Lumens
27K 2700K
30K 3000K
35K 3500K
40K 4000K
50K 5000K
SYM Symmetric type V
ASY Asymmetric type IV
PATH Pathway type III
MVOLT 2
120 2
208 2
240 2
277 2
347
480
SPA Square pole mounting (includes adapter)
RPA Round pole mounting
WBA Wall bracket
Control options Other options Finish (required)
Shipped installed
NLTAIR2 nLight AIR 2.0 enabled 3
PE Button photocell 3
FAO Field adjustable output 3
DMG 0-10v dimming wires pulled outside fixture (for use
with an external control, ordered separately)
SF Single Fuse 2
DF Double Fuse 2
L90 Left rotated optics
R90 Right rotated optics
Shipped separately
HS Houseside shield 5
DDBXD Dark bronze
DBLXD Black
DNAXD Natural aluminum
DWHXD White
DDBTXD Textured dark bronze
DBLBXD Textured black
DNATXD Textured natural aluminum
DWHGXD Textured white
Ordering Information EXAMPLE: RAD1 LED P3 30K SYM MVOLT RPA PE DNAXD
EPA: 0.75 ft2
(0.05 m2)
Length:
L1 24" (61cm)
L2 30" (60.96 cm)
Width: 24" (61cm)
Height: 4" (10.2cm)
Weight
(max):
29lbs
(13.15Kg)
NOTES
1 2700K and 3500K may require extended lead-times.
2 MVOLT driver operates on any line voltage from 120-277V (50/60
Hz). Single fuse (SF) requires 120, 277 or 347 voltage option.
Double fuse (DF) requires 208, 240 or 480 voltage option.
3 NLTAIR2 not available with PE or FAO. Must link to external
nLight Air network. Does not include occupancy sensor. For more
information refer to rSBOR pole mount sensor.
4 DMG not available with NLTAIR2 or FAO.
5 Also available as a separate accessory; see Accessories
information. Shield is field rotatable in 45º increments.
Accessories
Ordered and shipped separately.
RADHS Houseside shield (shield is white)
For more control options, visit DTL and ROAM online.
Page 150 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
COMMERCIAL OUTDOOR Rev. 12/08/25
RAD1 LED
Mounting
Visit Lithonia Lighting’s POLES CENTRAL to see our wide selection of poles,
accessories and educational tools.
RAD1 has a unique drilling pattern. Specify this drilling pattern when
specifying poles, per the table below.
DM19RAD Single unit DM29RAD 2 at 90° 1,2
DM28RAD 2 at 180° DM39RAD 3 at 90° *
DM49RAD 4 at 90° 1 DM32RAD 3 at 120°
Example: SSA 20 4C DM19RAD DDBXD
1. Round pole top must be 4.25" O.D. minimum.
2. Square pole top must be 3.125" O.D. minimum.
Drilling Template #20
2.750"
1.750
.875
Ø.406
Ø.563
Ø.406
Recommended Poles for use with RADEAN RAD1 LED Luminaires.
Acuity Part Number Description For luminaires: Used with Mounting
RSS 10 4B DM19RAD DDBXD 10' Round Straight Steel - Template #20 Drilling RAD1 LED RPA
RSS 12 4B DM19RAD DDBXD 12' Round Straight Steel - Template #20 Drilling RAD1 LED RPA
RSS 14 4B DM19RAD DDBXD 14' Round Straight Steel - Template #20 Drilling RAD1 LED RPA
RSS 16 4B DM19RAD DDBXD 16' Round Straight Steel - Template #20 Drilling RAD1 LED RPA
RSS 18 4B DM19RAD DDBXD 18' Round Straight Steel - Template #20 Drilling RAD1 LED RPA
RSS 20 4B DM19RAD DDBXD 20' Round Straight Steel - Template #20 Drilling RAD1 LED RPA
RSS 25 4B DM19RAD DDBXD 25' Round Straight Steel - Template #20 Drilling RAD1 LED RPA
SSS 10 4C DM19RAD DDBXD 10' Square Straight Steel -Template #20 Drilling RAD1 LED SPA
SSS 12 4C DM19RAD DDBXD 12' Square Straight Steel -Template #20 Drilling RAD1 LED SPA
SSS 14 4C DM19RAD DDBXD 14' Square Straight Steel -Template #20 Drilling RAD1 LED SPA
SSS 16 4C DM19RAD DDBXD 16' Square Straight Steel -Template #20 Drilling RAD1 LED SPA
SSS 18 4C DM19RAD DDBXD 18' Square Straight Steel -Template #20 Drilling RAD1 LED SPA
SSS 20 4C DM19RAD DDBXD 20' Square Straight Steel -Template #20 Drilling RAD1 LED SPA
SSS 25 4C DM19RAD DDBXD 25' Square Straight Steel -Template #20 Drilling RAD1 LED SPA
* Customer must verify pole loading per required design criteria and specified wind speed. Consult pole specification sheet for additional details.
Page 151 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
COMMERCIAL OUTDOOR Rev. 12/08/25
RAD1 LED
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative
of the configurations shown. Contact factory for performance data on any configurations not shown here.
Performance Data
Lumen Output
Use these factors to determine relative lumen output for
average ambient temperatures from 0-40°C (32-104°F).
Lumen Ambient Temperature (LAT) Multipliers Projected LED Lumen Maintenance
Data references the extrapolated performance projections for the RAD1 LED P5 platform
in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and
projected per IESNA TM-21-11).
To calculate LLF , use the lumen maintenance factor that corresponds to the desired number
of operating hours below. For other lumen maintenance values, contact factory.
Performance
Package
Input
Wattage Distribution
2700K 3000K 3500K 4000K 5000K
Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW
P1 25
ASY 3,103 1 0 1 122 3,207 1 0 1 126 3,285 1 0 1 129 3,362 1 0 1 132 3,362 1 0 1 132
PATH 2,695 2 0 2 106 2,785 2 0 2 110 2,853 2 0 2 112 2,920 2 0 2 115 2,920 2 0 2 115
SYM 3,271 2 0 1 129 3,380 2 0 1 133 3,461 2 0 1 136 3,543 2 0 1 139 3,543 2 0 1 139
P2 38
ASY 4,798 1 0 2 126 4,958 1 0 2 130 5,078 2 0 2 134 5,198 2 0 2 137 5,198 2 0 2 137
PATH 4,167 2 0 2 110 4,306 3 0 3 113 4,410 3 0 3 116 4,514 3 0 3 119 4,514 3 0 3 119
SYM 5,056 2 0 1 133 5,225 3 0 1 137 5,351 3 0 1 141 5,478 3 0 1 144 5,478 3 0 1 144
P3 54
ASY 6,779 2 0 2 126 7,005 2 0 2 131 7,174 2 0 2 134 7,344 2 0 2 137 7,344 2 0 2 137
PATH 5,887 3 0 3 110 6,084 3 0 3 113 6,231 3 0 3 116 6,378 3 0 3 119 6,378 3 0 3 119
SYM 7,144 3 0 2 133 7,382 3 0 2 138 7,561 3 0 2 141 7,739 3 0 2 144 7,739 3 0 2 144
P4 86
ASY 10,773 3 0 3 126 11,132 3 0 3 130 11,401 3 0 3 133 11,671 3 0 3 136 11,671 3 0 3 136
PATH 9,356 3 0 3 109 9,668 3 0 3 113 9,902 3 0 3 116 10,136 3 0 3 118 10,136 3 0 3 118
SYM 11,353 3 0 2 133 11,731 3 0 2 137 12,015 3 0 2 140 12,299 3 0 2 144 12,299 3 0 2 144
P5 122
ASY 15,001 3 0 3 123 15,501 3 0 3 127 15,876 3 0 3 130 16,251 3 0 3 133 16,251 3 0 3 133
PATH 13,028 4 0 4 107 13,462 4 0 4 110 13,788 4 0 4 113 14,114 4 0 4 116 14,114 4 0 4 116
SYM 15,808 4 0 3 130 16,335 4 0 3 134 16,731 4 0 3 137 17,126 4 0 3 140 17,126 4 0 3 140
Projected LED Lumen Maintenance
0 25,000 50,000 100,000
P1 1.00 0.96 0.91 0.82
P2 1.00 0.96 0.91 0.82
P3 1.00 0.96 0.91 0.82
P4 1.00 0.96 0.91 0.82
P5 1.00 0.95 0.89 0.78
Ambient LAT Factor
0°C 32°F 1.06
5°C 41°F 1.05
10°C 50°F 1.04
15°C 59°F 1.02
20°C 68°F 1.01
25°C 77°F 1.00
30°C 86°F 0.99
35°C 95°F 0.98
40°C 104°F 0.96
Current (A)
Lumen
Package
LED Drive
Current Voltage Wattage 120 208 240 277 347 480
P1 500 42.8 21.4 Input Current 0.22 0.13 0.11 0.1 0.08 0.06
System Watts 26 26 26 27 25 26
P2 770 43 33.1 Input Current 0.33 0.19 0.16 0.14 0.11 0.08
System Watts 39 39 39 39 38 38
P3 1100 43.2 47.5 Input Current 0.46 0.26 0.23 0.2 0.16 0.12
System Watts 55 54 54 54 54 54
P4 900 87.3 78.6 Input Current 0.73 0.42 0.36 0.32 0.25 0.18
System Watts 87 86 86 86 86 86
P5 1250 88.2 110.2 Input Current 1 0.58 0.5 0.44 0.35 0.25
System Watts 120 119 119 119 120 120
Electrical Load
Page 152 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2011-2025 Acuity Brands Lighting, Inc. All rights reserved.
COMMERCIAL OUTDOOR Rev. 12/08/25
RAD1 LED
FEATURES & SPECIFICATIONS
INTENDED USE
Pedestrian areas such as parks, campuses, pathways, courtyards and pedestrians malls.
CONSTRUCTION
Single-piece die-cast aluminum housing with nominal wall thickness of 0.125" on a 6mm thick
acrylic waveguide is fully gasketd with a single piece tubular silicone gasket.
FINISH
Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish
that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage
process ensures a minimum 3 mils thickness for a finish that can withstand extreme climate changes
without cracking or peeling. Standard Super Durable colors include dark bronze, black, natural
aluminum and white. Available in textured and non-textured finishes.
OPTICS
6MM thick acrylic waveguide with 360º flexible LED board. Available in 2700K, 3000K, 3500K, 4000K
and 5000K (80CRI) CCT configurations.
ELECTRICAL
Light engine consists of 96 high-efficacy LEDs mounted to a flexible circuit board and aluminum
heat sink, ensuring optimal thermal management and long life. Fixtures ship standard with 0-10v
dimming driver (order option DMG for connection to exterior controls). Class 1 electronic driver
has a power factor >90%, THD <20%, with an expected life of 100,000 hours with <1% failure rate.
Serviceable 10kV surge protection device meets a minimum Category C Low for operation (per
ANSI/IEEE C62.41.2).
INSTALLATION
Included luminaire and integral arm facilitate quick and easy installation. Stainless steel bolts fasten
the mounting block securely to poles and walls.
LISTINGS
CSA certified to U.S. and Canadian standards. Luminaire is IP65 rated. Rated for -40°C minimum
ambient.
DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all
versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC
Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified.
International Dark-Sky Association (IDA) Fixture Seal of Approval (FSA) is available for all products
on this page utilizing 3000K color or less.
GOVERNMENT PROCUREMENT
BAA – Buy America(n) Act: Product qualifies as a domestic end product under the Buy American
Act as implemented in the FAR and DFARS. Product also qualifies as manufactured in the United
States under DOT Buy America regulations.
BABA – Build America Buy America: Product qualifies as produced in the United States under the
definitions of the Build America, Buy America Act.
Please refer to www.acuitybrands.com/buy-american for additional information.
WARRANTY
5-year limited warranty. This is the only warranty provided and no other statements in this
specification sheet create any warranty of any kind. All other express and implied warranties are
disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-
and-conditions
Note: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.
Orientation Diagrams To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s RAD1 LED homepage.
RAD1 SYM RAD1 SYM R90RAD1 SYM HS
House side shield
RAD1 ASY Standard RAD1 ASY R90RAD1 ASY HS RAD1 ASY L90
House side shield
RAD1 PATH RAD1 PATH R90RAD1 PATH HS
House side shield
Standard Optic House side Shield Rotated R90
Page 153 of 161
RCNY LED
Series Package Color Temperature CRI Lens
RCNY LED ALO1 2,000-12,000 Lumens
ALO2 4,000-24,000 Lumens
30K 3000K
40K 4000K
50K 5000K
57K 5700K
AMBLW (Limited Wavelength) 1
70CRI
80CRI
90CRI 2
AMCRI 3
SYMC Symmetric Clear Lens
ASYC Asymmetric Clear Lens
SYMF Symmetric Frost Lens
SYMG Symmetric Glass Lens
Voltage Trim Trim Finish Option
MVOLT 120-277V
HVOLT 347-480V
BZS 11.5" Square Bezel
BZL 18.0" Square Bezel 4
DWHXD White
DBLXD Black
DDBXD Bronze
DNAXD Natural Aluminum
CCE Coastal Protection
SPD10KV 10K Surge Protection
DMG 5 0-10V dimming wires pulled outside fixture
(for use with an external control, ordered separately)
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2024-2026 Acuity Brands Lighting, Inc. All rights reserved.
RCNY LED
Rev. 06/10/26
COMMERCIAL OUTDOOR
RCNY LED
Recessed LED
Canopy/Ceiling
Luminaire
Ordering Information EXAMPLE: RCNY LED ALO2 50K 70CRI SYMC MVOLT BZS DWHXD
NOTES
1. Only available with ALO2 and AMCRI.
2. 90CRI not available with 57K.
3. Only available with ALO2 and AMBLW.
4. BZL Only Available with SYMG Lens
5. FAO not included with fixture, ALO2 will be set
at 24,000 lumens and ALO1 at 12,000 Lumens.
Catalog
Number
Notes
Type
Hit the Tab key or mouse over the page to see all interactive elements.
Introduction
The RCNY LED recessed luminaire is designed to
provide exceptional energy savings and versatility
in one fixture. With a compact design the RCNY
provides superior illumination while blending into the
canopy space seamlessly. The RCNY is unique in that
as a recessed canopy it can be installed in both 12"
and 16" canopy decks. Features such as Adjustable
Lumen Output Dial with 8 Settings and forward throw
distribution (ASYC) option make the RCNY one of
the most versatile gas station canopies in the market.
Lumen dial and driver are both accessible from below.
With up to 179 LPW the RCNY LED delivers up to
90% in energy savings when replacing metal halide
luminaires. With over 100,000 hour life expectancy
(12+ years of 24/7 continuous operation), the RCNY
LED luminaire provides significant maintenance
savings over traditional luminaires. Wet location
junction box available upon request.
RCNY LED
Width: 11.5"
Height: 5.9"
Length: 11.5"
Weight: 14lbs
Specifications
Accessories
Ordered and shipped separately.
Catalog Description Use Dimensions
FP12RM* RCNY Backplate for 12" Decks Covers Existing Hole if Larger than Fixture 11.5" x 24" x 18GA Galv Steel
FP16RM* RCNY Backplate for 16" Decks Covers Existing Hole if Larger than Fixture 15.5" x 24" x 18GA Galv Steel
BP18RM* RCNY 18" Beautyplate Covers Existing Footprint of Existing Fixture 18" x 18" x 16GA Aluminum
BP26RM* RCNY 26" Beautyplate Covers Existing Footprint of Existing Fixture 26" x 26" x 16GA Aluminum
WLJBX2 Waterproof J-Box 1/2 Inch with Cover For Power Supply Wiring 2.8" x 4.6" x 2.0" Aluminum
* Add “U" to the end of the catalog number for individual unit pack or “J6" for packs of 6 units
Page 154 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2024-2026 Acuity Brands Lighting, Inc. All rights reserved.
RCNY LED
Rev. 06/10/26
COMMERCIAL OUTDOOR
Performance Data
Full photometric data report available within 2 weeks from request. Contact Acuity Tech Support.Photometric Diagrams
Performance
Package Setting System
Watts
30K
(3000K, 70 CRI)
40K
(4000K, 70 CRI)
50K
(5000K, 70 CRI)
50K
(5000K, 90 CRI)
Lumens LPW Lumens LPW Lumens LPW Lumens LPW
ALO2 1 24 3,681 153 3,795 158 3,843 160 3,436 143
ALO2 2 42 6,933 165 7,149 170 7,238 172 6,473 154
ALO2 3 57 9,677 170 9,978 175 10,103 177 9,035 159
ALO2 4 74 12,606 170 12,998 176 13,162 178 11,770 159
ALO2 5 89 15,249 171 15,723 177 15,920 179 14,237 160
ALO2 6 107 18,182 170 18,747 175 18,983 177 16,975 159
ALO2 7 123 20,446 166 21,082 171 21,347 174 19,089 155
ALO2 8 132 22,143 168 22,831 173 23,118 175 20,003 152
ALO1 1 14 1,956 140 2,017 144 2,042 146 1,842 132
ALO1 2 24 3,684 154 3,799 158 3,846 160 3,470 145
ALO1 3 32 5,142 161 5,302 166 5,369 168 4,844 151
ALO1 4 40 6,699 167 6,907 173 6,994 175 6,310 158
ALO1 5 48 8,103 169 8,355 174 8,460 176 7,632 159
ALO1 6 57 9,662 170 9,962 175 10,087 177 9,101 160
ALO1 7 66 10,865 165 11,203 170 11,343 172 10,234 155
ALO1 8 72 11,767 163 12,132 169 12,285 171 11,083 154
Symmetric Clear Lens
SYMMETRIC CLEAR LENS ASYMMETRIC CLEAR LENS
/0/1/2/3/0/0/4/i255/6/7/0/2/0/8 /9/2/4/10/11/i255/4/9/6/0/4/2
/12/13/14/13/15/16/17/18/i255/20/12/21/22/i255/15/23/24/i255/13/15/16/25/i255/26/27/28/i255/29/27/12/20/30/i255/13/31/22/12/i255/32/33/16/15/14
/32/34/35/36/37/34/38/39/36/40/41/40/18 /15/42/39/43/44/35/42/34/i255/15/42/45/43/39/42/35/45
/14/41/46/39/i255/47/18 /30/31/48/i255/25/49/50/49/51/29
/14/41/46/39/i255/15/34/52/18 /13/12/53/30/14/22/i255/54/20/13/21/24/31/i255/15/30/17/55/14/30/21/17/56/i255/24/23/12/13/14/53/20/i255/15/13/54
/14/41/46/39/i255/24/34/39/41/18 /51/57/50/29/57/25/27/25/49
/12/34/39/34/58/44/45/18 /20/12/21/22/i255/15/23/24/i255/13/15/16/25/i255/26/27/28/i255/29/27/12/20/30/i255/13/31/22/12/i255/32/33/16/15/14
/24/41/46/38/40/42/59/39/42/44/35/18 /20/12/21/22/i255/15/23/24/i255/13/15/16/25/i255/26/27/28/i255/29/27/12/20/30/i255/13/31/22/12/i255/32/33/16/15/14
/15/34/60/59/i255/12/34/39/34/58/44/45/18 /21/42/38/43/42/34
/15/34/60/59/i255/16/36/39/59/36/39/18 /14/44/39/34/58/i255/58/36/60/42/35/34/42/40/41/i255/15/36/60/41/35/46/18/i255/50/61/62/63/29/64/49/56/i255/34/52/46/44/58/36/39/41/i255/59/43/44/39/44/60/41/39/40/65/i255/66
/54/34/58/58/34/46/39/i255/57/i255/24/40/42/67/41/40/18 /16/46/40/34/60/56/i255/16/46/40/34/60
/30/35/59/36/39/i255/68/34/39/39/34/45/41/18 /50/62/63/64/62
/23/37/37/42/38/34/38/65/18 /50/62/25/64/27/29/i255/69/15/36/60/41/35/46/i255/14/44/39/34/58/i255/57/i255/30/35/59/36/39/i255/68/34/39/39/34/45/41/70
/15/36/60/42/35/44/36/46/i255/16/59/41/35/42/35/45/18 /20/41/38/39/34/35/45/58/41/i255/69/15/18/i255/61/64/26/25/71/56/i255/68/18/i255/61/64/26/25/71/70
/32/34/72/i255/12/73/18 /61/56/27/63/25/64/27/i255/34/39/i255/55/44/40/42/74/44/35/39/34/58/18/i255/27/75/56/i255/33/41/40/39/42/38/34/58/18/i255/49/29/64/26/75
/20/44/34/73/76/34/65/i255/12/58/34/46/46/18 /33/23/20/22/i255/31/55/16/20/14/56/i255/14/22/77/23/i255/30/30/30
/66/14/41/46/39/i255/52/34/46/41/73/i255/44/35/i255/34/52/46/44/58/36/39/41/i255/59/43/44/39/44/60/41/39/40/65/i255/76/43/41/40/41/i255/58/34/60/59/i255/58/36/60/41/35/46/78/58/36/60/41/35/46/i255/39/44/39/34/58/64
/66/12/36/39/44/37/37/i255/12/58/34/46/46/42/37/42/38/34/39/42/44/35/i255/34/35/73/i255/41/37/37/42/38/42/41/35/38/65/i255/38/34/35/35/44/39/i255/52/41/i255/59/40/44/59/41/40/58/65/i255/38/34/58/38/36/58/34/39/41/73/i255/37/44/40/i255/34/52/46/44/58/36/39/41/i255/59/43/44/39/44/60/41/39/40/65/64
/33/42/46/36/34/58/i255/77/43/44/39/44/60/41/39/40/42/38/i255/14/44/44/58/i255/50/64/25/64/49/51/i255/12/44/59/65/40/42/45/43/39/i255/25/27/25/49/56/i255/13/38/36/42/39/65/i255/54/40/34/35/73/46/i255/15/42/45/43/39/42/35/45/64
/14/43/42/46/i255/77/43/44/39/44/60/41/39/40/42/38/i255/40/41/59/44/40/39/i255/43/34/46/i255/52/41/41/35/i255/45/41/35/41/40/34/39/41/73/i255/36/46/42/35/45/i255/60/41/39/43/44/73/46/i255/40/41/38/44/60/60/41/35/73/41/73/i255/52/65/i255/39/43/41/i255/30/23/31/21/13/64/i255/12/34/58/38/36/58/34/39/42/44/35/46/i255/34/40/41/i255/52/34/46/41/73/i255/44/35/i255/77/43/44/39/44/60/41/39/40/42/38/i255/73/34/39/34/i255/59/40/44/67/42/73/41/73
/0/1/2/3/0/0/4/i255/6/7/0/2/0/8 /9/2/4/10/11/i255/4/9/6/0/4/2
/12/13/14/13/15/16/17/18/i255/20/12/21/22/i255/15/23/24/i255/13/15/16/25/i255/26/27/28/i255/29/27/12/20/30/i255/31/22/32/12/i255/32/33/16/15/14/i255/34/i255/13/15/16/i255/31/23/14/14/30/21/17/i255/35/i255/36/31/32/37/31
/32/38/39/40/41/38/42/43/40/44/45/44/18 /15/46/43/47/48/39/46/38/i255/15/46/49/47/43/46/39/49
/14/45/50/43/i255/51/18 /30/31/52/i255/25/53/54/53/29/35
/14/45/50/43/i255/15/38/55/18 /13/12/56/30/14/22/i255/57/20/13/21/24/31/i255/15/30/17/58/14/30/21/17/59/i255/24/23/12/13/14/56/20/i255/15/13/57
/14/45/50/43/i255/24/38/43/45/18 /60/61/54/27/61/25/27/25/53
/12/38/43/38/62/48/49/18 /20/12/21/22/i255/15/23/24/i255/13/15/16/25/i255/26/27/28/i255/29/27/12/20/30/i255/31/22/32/12/i255/32/33/16/15/14/i255/34/i255/13/15/16/i255/31/23/14/14/30/21/17/i255/35/i255/36/31/32/37/31
/24/45/50/42/44/46/63/43/46/48/39/18 /20/12/21/22/i255/15/23/24/i255/13/15/16/25/i255/26/27/28/i255/29/27/12/20/30/i255/31/22/32/12/i255/32/33/16/15/14/i255/34/i255/13/15/16/i255/31/23/14/14/30/21/17/i255/35/i255/36/31/32/37
/15/38/64/63/i255/12/38/43/38/62/48/49/18 /21/46/42/47/46/38
/15/38/64/63/i255/16/40/43/63/40/43/18 /14/48/43/38/62/i255/62/40/64/46/39/38/46/44/45/i255/15/40/64/45/39/50/18/i255/25/27/53/54/54/65/35/59/i255/38/55/50/48/62/40/43/45/i255/63/47/48/43/48/64/45/43/44/66/i255/67
/57/38/62/62/38/50/43/i255/61/i255/24/44/46/68/45/44/18 /16/50/44/38/64/59/i255/16/50/44/38/64
/30/39/63/40/43/i255/69/38/43/43/38/49/45/18 /54/70/35/65/70
/23/41/41/46/42/38/42/66/18 /54/53/29/65/26/71/i255/36/15/40/64/45/39/50/i255/14/48/43/38/62/i255/61/i255/30/39/63/40/43/i255/69/38/43/43/38/49/45/37
/15/40/64/46/39/48/40/50/i255/16/63/45/39/46/39/49/18/20/45/42/43/38/39/49/62/45/i255/36/15/18/i255/35/65/27/53/72/59/i255/69/18/i255/35/65/27/53/72/37
/32/38/73/i255/12/74/18 /60/59/54/70/29/65/27/i255/38/43/i255/58/48/44/46/75/48/39/43/38/62/18/i255/35/26/76/59/i255/33/45/44/43/46/42/38/62/18/i255/25/65/26/76
/20/48/38/74/77/38/66/i255/12/62/38/50/50/18 /14/66/63/45/i255/33/31
/67/14/45/50/43/i255/55/38/50/45/74/i255/48/39/i255/38/55/50/48/62/40/43/45/i255/63/47/48/43/48/64/45/43/44/66/i255/77/47/45/44/45/i255/62/38/64/63/i255/62/40/64/45/39/50/78/62/40/64/45/39/50/i255/43/48/43/38/62/65
/67/12/40/43/48/41/41/i255/12/62/38/50/50/46/41/46/42/38/43/46/48/39/i255/38/39/74/i255/45/41/41/46/42/46/45/39/42/66/i255/42/38/39/39/48/43/i255/55/45/i255/63/44/48/63/45/44/62/66/i255/42/38/62/42/40/62/38/43/45/74/i255/41/48/44/i255/38/55/50/48/62/40/43/45/i255/63/47/48/43/48/64/45/43/44/66/65
/33/46/50/40/38/62/i255/79/47/48/43/48/64/45/43/44/46/42/i255/14/48/48/62/i255/54/65/25/65/53/60/i255/12/48/63/66/44/46/49/47/43/i255/25/27/25/53/59/i255/13/42/40/46/43/66/i255/57/44/38/39/74/50/i255/15/46/49/47/43/46/39/49/65
/14/47/46/50/i255/79/47/48/43/48/64/45/43/44/46/42/i255/44/45/63/48/44/43/i255/47/38/50/i255/55/45/45/39/i255/49/45/39/45/44/38/43/45/74/i255/40/50/46/39/49/i255/64/45/43/47/48/74/50/i255/44/45/42/48/64/64/45/39/74/45/74/i255/55/66/i255/43/47/45/i255/30/23/31/21/13/65/i255/12/38/62/42/40/62/38/43/46/48/39/50/i255/38/44/45/i255/55/38/50/45/74/i255/48/39/i255/79/47/48/43/48/64/45/43/44/46/42/i255/74/38/43/38/i255/63/44/48/68/46/74/45/74
Performance
Package Setting System
Watts
30K
(3000K, 70 CRI)
40K
(4000K, 70 CRI)
50K
(5000K, 70 CRI)
50K
(5000K, 90 CRI)
Lumens LPW Lumens LPW Lumens LPW Lumens LPW
ALO2 1 24 3,283 137 3,385 141 3,427 143 3,065 128
ALO2 2 42 6,184 147 6,376 152 6,456 154 5,774 137
ALO2 3 57 8,632 151 8,900 156 9,012 158 8,059 141
ALO2 4 74 11,244 152 11,594 157 11,740 159 10,498 142
ALO2 5 89 13,601 153 14,024 158 14,200 160 12,699 143
ALO2 6 107 16,217 152 16,721 156 16,932 158 15,141 142
ALO2 7 123 18,237 148 18,804 153 19,040 155 17,027 138
ALO2 8 132 19,750 150 20,364 154 20,620 156 18,440 140
ALO1 1 14 1,745 125 1,799 129 1,821 130 1,643 117
ALO1 2 24 3,286 137 3,388 141 3,431 143 3,095 129
ALO1 3 32 4,587 143 4,729 148 4,789 150 4,320 135
ALO1 4 40 5,975 149 6,161 154 6,238 156 5,628 141
ALO1 5 48 7,227 151 7,452 155 7,546 157 6,808 142
ALO1 6 57 8,618 151 8,886 156 8,997 158 8,117 142
ALO1 7 66 9,691 147 9,992 151 10,118 153 9,128 138
ALO1 8 72 10,495 146 10,821 150 10,957 152 9,886 137
Symmetric Frost Lens
Performance
Package Setting System
Watts
30K
(3000K, 70 CRI)
40K
(4000K, 70 CRI)
50K
(5000K, 70 CRI)
50K
(5000K, 90 CRI)
Lumens LPW Lumens LPW Lumens LPW Lumens LPW
ALO2 1 26 3,193 123 3,411 131 3,549 137 2,378 91
ALO2 2 45 5,628 125 6,012 134 6,096 135 4,192 93
ALO2 3 61 7,957 130 8,500 139 8,618 141 5,927 97
ALO2 4 79 10,142 128 10,834 137 10,984 139 7,554 96
ALO2 5 96 12,281 128 13,119 137 13,301 139 9,147 95
ALO2 6 114 14,093 124 15,055 132 15,264 134 10,497 92
ALO2 7 132 15,860 120 16,943 128 17,178 130 11,813 89
ALO2 8 141 16,293 116 18,078 128 18,329 130 12,605 89
ALO1 1 14 1,587 113 1,696 121 1,719 123 1,182 84
ALO1 2 25 2,798 112 2,989 120 3,030 121 2,084 83
ALO1 3 31 3,877 125 4,142 134 4,199 135 2,888 93
ALO1 4 39 5,041 129 5,385 138 5,460 140 3,755 96
ALO1 5 47 6,105 130 6,521 139 6,612 141 4,547 97
ALO1 6 53 7,005 132 7,483 141 7,587 143 5,218 98
ALO1 7 60 7,884 131 8,422 140 8,539 142 5,872 98
ALO1 8 66 8,412 127 8,986 136 9,111 138 6,266 95
Asymmetric Clear Lens
B U G
SYMC 4 0 2
SYMF 4 0 2
ASYC 3 0 2
RCNY LED ALO2 50K
Performance
Package Setting System
Watts
30K
(3000K, 70 CRI)
40K
(4000K, 70 CRI)
50K
(5000K, 70 CRI)
50K
(5000K, 90 CRI)
Lumens LPW Lumens LPW Lumens LPW Lumens LPW
ALO2 1 24 3,511 146 3,620 151 3,666 153 3,278 137
ALO2 2 42 6,614 157 6,819 162 6,905 164 6,175 147
ALO2 3 57 9,231 162 9,518 167 9,638 169 8,619 151
ALO2 4 74 12,025 163 12,399 168 12,555 170 11,227 152
ALO2 5 89 14,546 163 14,998 169 15,186 171 13,581 153
ALO2 6 107 17,344 162 17,883 167 18,108 169 16,193 151
ALO2 7 123 19,504 159 20,110 163 20,363 166 18,209 148
ALO2 8 132 21,122 160 21,779 165 22,052 167 19,721 149
ALO1 1 14 1,866 133 1,924 137 1,948 139 1,757 126
ALO1 2 24 3,514 146 3,624 151 3,669 153 3,310 138
ALO1 3 32 4,905 153 5,058 158 5,121 160 4,620 144
ALO1 4 40 6,390 160 6,589 165 6,672 167 6,019 150
ALO1 5 48 7,729 161 7,970 166 8,070 168 7,281 152
ALO1 6 57 9,216 162 9,503 167 9,622 169 8,681 152
ALO1 7 66 10,364 157 10,686 162 10,820 164 9,762 148
ALO1 8 72 11,224 156 11,573 161 11,718 163 10,572 147
Symmetric Glass Lens
Page 155 of 161
1 Acuity Way, Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2024-2026 Acuity Brands Lighting, Inc. All rights reserved.
RCNY LED
Rev. 06/10/26
COMMERCIAL OUTDOOR
Line Art
5.56 5.93
.33
4.50
1.06
FIGURE 1: SIDE VIEW OF LUMINAIRE
10.12
10.12
FIGURE 2: TOP SIDE OF CANOPY
11.54
11.54
FIGURE 3: BOTTOM SIDE OF CANOPY
WITH BZS OPTION
18.000
18.000
FIGURE 4: WITH BZS OPTION
FEATURES & SPECIFICATIONS
INTENDED USE
The Velarium RCNY LED recessed luminaire is designed to provide exceptional energy savings
and versatility in one fixture. With a compact design the RCNY provides superior illumination while
blending into the canopy space seamlessly. The RCNY is unique in that as a recessed canopy it
can be installed in both 12" and 16" canopy decks. Features such as Adjustable Lumen Output
and forward throw distribution option make the RCNY one of the most versatile gas station
canopies in the market. With up to 179 LPW the RCNY LED delivers up to 90% in energy savings
when replacing metal halide luminaires. With over 100,000 hour life expectancy (12+ years of 24/7
continuous operation), the RCNY LED luminaire provides significant maintenance savings over
traditional luminaires.
CONSTRUCTION
Die-cast aluminum housing for the light engine is optimized for thermal management. Driver is
accessible from below without removing fixture for easy maintenance. The light engine housing
is completely sealed against moisture and environmental contaminants (IP66) and is suitable for
hose-down application.
ELECTRICAL
Light engine consists of high-efficacy LEDs mounted to metal-core circuit boards to maximize
heat dissipation and promote long life (up to L77/100,000 hours at 25°C). The electronic driver has
a power factor of >90% and THD <20%. Standard 6KV surge protection. Operating temperature
-40C to 35C. Driver is a 0-10V dimming driver.
INSTALLATION
The product can be installed by one person to a 12" or 16" deck panel. The Adjustable Lumen
Output (ALO) module in the driver box allows the contractor to customize the lumens (8 levels)
based on application needs. Two trim options provide clean look once installation is complete.
LISTINGS
CSA Certified to meet U.S. and Canadian standards. IP66 Rated for wet locations.
Tested in accordance with IESNA LM-79 and LM-80 standards.
DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all
versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC
Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified.
WARRANTY
5-year limited warranty. This is the only warranty provided and no other statements in this
specification sheet create any warranty of any kind. All other express and implied warranties are
disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-
and-conditions
Note: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
The product images shown are for illustration purposes only and may not be an exact
representation of the product.
Specifications subject to change without notice.
Page 156 of 161
Introduction
The WDGE LED family is designed to meet specifier’s every wall-
mounted lighting need in a widely accepted shape that blends
with any architecture. The clean rectilinear design comes in four
sizes with lumen packages ranging from 1,200 to 25,000 lumens,
providing a true site-wide solution. Embedded with nLight® AIR
wireless controls, the WDGE family provides additional energy
savings and code compliance.
WDGE2 delivers up to 6,000 lumens with a soft, non-pixelated
light source, creating a visually comfortable environment. When
combined with multiple integrated emergency battery backup
options, including an 18W cold temperature option, the WDGE2
becomes the ideal wall-mounted lighting solution for pedestrian
scale applications in any environment.
1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2019-2026 Acuity Brands Lighting, Inc. All rights reserved.
WDGE2 LED
Rev. 07/06/26
COMMERCIAL OUTDOOR
WDGE2 LED
Architectural Wall Sconce
Visual Comfort Optic
Catalog
Number
Notes
Type
Depth (D1): 7"
Depth (D2): 1.5"
Height: 9"
Width: 11.5"
Weight:
(without options) 13.5 lbs
Hit the Tab key or mouse over the page to see all interactive elements.
Specifications
Series Package Color Temperature CRI Distribution Voltage Mounting
WDGE2 LED P1 1
P2 1
P3 1
P4 1
P5 1
P1SW
P2SW
P3SW
Door with small window (SW) is
required to accommodate sensors.
See page 2 for more details.
27K 2700K
30K 3000K
35K 3500K
40K 4000K
50K 2 5000K
80CRI
90CRI
VF Visual comfort
forward throw
VW Visual comfort
wide
MVOLT
347 3
480 3
Shipped included
SRM Surface mounting bracket
ICW Indirect Canopy/Ceiling
Washer bracket (dry/damp
locations only)4
Shipped separately
AWS 3/8inch Architectural wall spacer5
PBBW Surface-mounted back box (top, left,
right conduit entry). Use when there
is no junction box available.5
Options Finish
E4WH Emergency battery backup, Certified in CA Title 20
MAEDBS (4W, 0°C min)
E10WH Emergency battery backup, Certified in CA Title 20
MAEDBS (10W , 5°C min)
E20WC Emergency battery backup, Certified in CA Title 20
MAEDBS (18W , -20°C min)
PE Photocell, Button Type 6
DS Dual switching (comes with 2 drivers and 2 light
engines; see page 3 for details) 7
DMG 0-10V dimming wires pulled outside fixture (for use
with an external control, ordered separately) 8
BCE Bottom conduit entry for back box (PBBW). Total of 4
entry points.
DSLE Dual Switching (1 Driver, 2 Light Engines)
CCE Coastal Construction5
Standalone Sensors/Controls (only available with P1SW , P2SW & P3SW)
PIR Bi-level (100/35%) motion sensor for 8-15’ mounting heights. Intended for use on switched circuits with external dusk to
dawn switching.
PIRH Bi-level (100/35%) motion sensor for 15-30’ mounting heights. Intended for use on switched circuits with external dusk
to dawn switching
PIR1FC3V Bi-level (100/35%) motion sensor for 8-15’ mounting heights with photocell pre-programmed for dusk to dawn operation.
PIRH1FC3V Bi-level (100/35%) motion sensor for 15-30’ mounting heights with photocell pre-programmed for dusk to dawn operation.
Networked Sensors/Controls (only available with P1SW , P2SW & P3SW)
NLTAIR2 PIR Embedded wireless controls by nLight with Passive Infrared Occ sensor and on/off photocell for 8-15' mounting heights.
NLTAIR2 PIRH Embedded wireless controls by nLight with Passive Infrared Occ sensor and on/off photocell for 15-30' mounting heights.
NLTAIREM2 PIR Embedded wireless controls by nLight with UL924 listed emegency operation, Passive Infrared Occ sensor and on/off
photocell for 8-15' mounting heights9
NLTAIREM2 PIRH Embedded wireless controls by nLight with UL924 listed emegency operation, Passive Infrared Occ sensor and on/off
photocell for 15-30' mounting heights9
See page 4 for out of box functionality
DDBXD Dark bronze
DBLXD Black
DNAXD Natural
aluminum
DWHXD White
DSSXD Sandstone
DDBTXD Textured dark
bronze
DBLBXD Textured black
DNATXD Textured natural
aluminum
DWHGXD Textured white
DSSTXD Textured
sandstone
Ordering Information EXAMPLE: WDGE2 LED P3 40K 80CRI VF MVOLT SRM DDBXD
WDGE LED Family Overview
D1W
D2
H
Luminaire Optics Standard EM, 0°C Cold EM, -20°C Sensor Approximate Lumens (4000K, 80CRI)
P0 P1 P2 P3 P4 P5 P6
WDGE1 LED Visual Comfort 4W -- 750 1,200 2,000 -- -- -- --
WDGE2 LED Visual Comfort 10W 18W Standalone / nLight -- 1,200 2,000 3,000 4,500 6,000 --
WDGE2 LED Precision Refractive 10W 18W Standalone / nLight 700 1,200 2,000 3,200 4,200 -- --
WDGE3 LED Precision Refractive 15W 18W Standalone / nLight 6,000 7,500 8,500 10,000 12,000 -- --
WDGE4 LED Precision Refractive Standalone / nLight -- 12,000 16,000 18,000 20,000 22,000 25,000
Items marked by a shaded background qualify for the Design Select program and ship in 15 days or less. To learn more about Design Select, visit www.acuitybrands.com/designselect.
*See ordering tree for details
Page 157 of 161
NOTES
1 P1-P5 not available with sensors/controls. Sensors/controls only available with
P1SW, P2SW and P3SW.
2 50K not available in 90CRI.
3 347V and 480V not available with E4WH, E10WH, E20WC, DS or DSLE.
4 Not qualified for DLC. Not available with emergency battery backup or
sensors/controls.
5 For PBBW and AWS with CCE option,require an RFA.
6 PE not available in 480V or with sensors/controls.
7 DS option not available with E4WH, E10WH, E20WC or sensors/controls.
8 DMG option not available with sensors/controls.
9 Available with MVOLT only and only rated to 25C ambient.
Accessories
Ordered and shipped separately.
WDGEAWS DDBXD WDGE 3/8inch Architectural Wall Spacer (specify finish)
WDGE2PBBW DDBXD U WDGE2 surface-mounted back box (specify finish)
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown,
within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here.
Default configuration with no sensors/controls.
Power Packages: P1, P2, P3, P4, P5
Small Window (SW) configuration
Power Packages: P1SW, P2SW, P3SW
Configuration with sensors/controls
Power Packages: P1SW, P2SW, P3SW
Performance
Package
System
Watts Dist. Type
27K (2700K, 80 CRI) 30K (3000K, 80 CRI) 35K (3500K, 80 CRI) 40K (4000K, 80 CRI) 50K (5000K, 80 CRI)
Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G
P1 / P1SW 10W
VF 1,166 119 0 0 0 1,209 123 0 0 0 1,251 128 0 0 0 1,256 128 0 0 0 1,254 128 0 0 0
VW 1,197 122 0 0 0 1,241 126 0 0 0 1,284 131 0 0 0 1,289 131 0 0 0 1,286 131 0 0 0
P2 / P2SW 15W
VF 1,878 129 1 0 0 1,947 134 1 0 0 2,015 139 1 0 0 2,023 139 1 0 0 2,019 139 1 0 0
VW 1,927 133 1 0 0 1,997 137 1 0 0 2,067 142 1 0 0 2,075 143 1 0 0 2,071 143 1 0 0
P3 / P3SW 23W
VF 2,908 129 1 0 0 3,015 134 1 0 0 3,119 138 1 0 0 3,132 139 1 0 0 3,126 139 1 0 0
VW 2,983 132 1 0 0 3,093 137 1 0 0 3,200 142 1 0 0 3,213 143 1 0 0 3,206 142 1 0 0
P4 35W
VF 4,096 117 1 0 1 4,247 121 1 0 1 4,394 126 1 0 1 4,412 126 1 0 1 4,403 126 1 0 1
VW 4,202 120 1 0 0 4,357 125 1 0 1 4,508 129 1 0 1 4,526 129 1 0 1 4,517 129 1 0 1
P5 48W
VF 5,567 115 1 0 1 5,772 119 1 0 1 5,972 123 1 0 1 5,996 124 1 0 1 5,984 124 1 0 1
VW 5,711 118 1 0 1 5,921 122 1 0 1 6,127 126 1 0 1 6,151 127 1 0 1 6,139 127 1 0 1
Option Dist. Type Lumens
E4WH
VF 646
VW 647
E10WH
VF 1,658
VW 1,701
E20WC
VF 2,840
VW 2,913
Lumen Output in Emergency
Mode (4000K, 80 CRI)
1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2019-2026 Acuity Brands Lighting, Inc. All rights reserved.
WDGE2 LED
Rev. 07/06/26
COMMERCIAL OUTDOOR
Performance Data
Lumen Output
Use these factors to determine relative lumen output for average ambient
temperatures from 0-40°C (32-104°F).
Lumen Ambient Temperature (LAT) Multipliers
Ambient Lumen Multiplier
0°C 32°F 1.03
10°C 50°F 1.02
20°C 68°F 1.01
25°C 77°F 1.00
30°C 86°F 0.99
40°C 104°F 0.98
Projected LED Lumen Maintenance
Data references the extrapolated performance projections for the platforms noted in a 25°C
ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per
IESNA TM-21-11).
To calculate LLF , use the lumen maintenance factor that corresponds to the desired number of
operating hours below. For other lumen maintenance values, contact factory.
Operating Hours 0 25,000 50,000 100,000
Lumen Maintenance Factor 1.0 >0.96 >0.95 >0.91
Performance
Package System Watts
Current (A)
120V 208V 240V 277V 347V 480V
P1 / P1SW
10W 0.082 0.049 0.043 0.038 -- --
13W -- -- -- -- 0.046 0.033
P2 / P2SW
15W 0.132 0.081 0.072 0.064 -- --
18W -- -- -- -- 0.056 0.041
P3 / P3SW
23W 0.195 0.114 0.100 0.088 -- --
26W -- -- -- -- 0.079 0.058
P4
35W 0.302 0.175 0.152 0.134 -- --
38W -- -- -- -- 0.115 0.086
P5
48W 0.434 0.241 0.211 0.184 -- --
52W -- -- -- -- 0.157 0.119
Electrical Load
CCT Multiplier
27K 0.845
30K 0.867
35K 0.845
40K 0.885
50K 0.898
Lumen Multiplier for 90CRI
Page 158 of 161
To see complete photometric reports or download .ies files for this product, visit the Lithonia Lighting WDGE LED homepage.
Tested in accordance with IESNA LM-79 and LM-80 standards.
1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2019-2026 Acuity Brands Lighting, Inc. All rights reserved.
WDGE2 LED
Rev. 07/06/26
COMMERCIAL OUTDOOR
Photometric Diagrams
The emergency battery backup is integral to the luminaire — no external housing required! This design provides reliable emergency operation while maintaining
the aesthetics of the product. All emergency battery backup configurations include an independent secondary driver with an integral relay to immediately
detect loss of normal power and automatically energize the luminaire. The emergency battery will power the luminaire for a minimum duration of 90 minutes
(maximum duration of three hours) from the time normal power is lost and maintain a minimum of 60% of the light output at the end of 90minutes.
Applicable codes: NFPA 70/NEC – section 700.16, NFPA 101 Life Safety Code Section 7.9
The examples below show illuminance of 1 fc average and 0.1 fc minimum in emergency mode with E10WH or E20WC and VF distribution.
Emergency Egress Options
Emergency Battery Backup
The dual switching option offers operational redundancy that certain
codes require. With this option the luminaire comes integrated with two
drivers and two light engines. These work completely independent to
each other so that a failure of any individual component does not cause
the whole luminaire to go dark.
Applicable codes: NFPA 70/NEC – section 700.16, NFPA 101 Life Safety
Code Section 7.9
Dual Switching (DS) Option
WDGE2 LED xx 40K 80CRI VF MVOLT E10WH
Grid = 10ft x 10ft
30'
0.1 fc min.
1.0 fc avg.
8'
22'
40'
0.1 fc min.
1.0 fc avg.
12'
26'
8' MH 12' MH
40'
0.1 fc min.
1.0 fc avg.
12'
31'
40'
0.1 fc min.
1.0 fc avg.
15'
37'
12' MH 15' MH
WDGE2 LED xx 40K 80CRI VF MVOLT E20WC
LEGEND
0.25 fc
0.5 fc
3.0 fc
1.0 fc
WDGE2 LED P3 40K 80CRI VWWDGE2 LED P3 40K 80CRI VW
MH = 10ft
Grid = 10ft x 10ft
WDGE2 LED P3 40K 80CRI VFWDGE2 LED P3 40K 80CRI VF
The dual switching option offers operational redundancy that certain
codes require. With this option the luminaire comes integrated with one
driver and two light engines. These work completely independent to each
other so that a failure of either light engine does not cause the whole
luminaire to go dark.
Applicable codes: NFPA 70/NEC – section 700.16, NFPA 101 Life Safety
Code Section 7.9
Dual Switching Light Engine (DSLE) Option
Page 159 of 161
1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2019-2026 Acuity Brands Lighting, Inc. All rights reserved.
WDGE2 LED
Rev. 07/06/26
COMMERCIAL OUTDOOR
Motion/Ambeint sensor (Sensor Switch MSOD) is integrated into the the luminaire. The sensor provides both Motion and Daylight based dimming of the
luminaire. For motion detection, the sensor utilizes 100% Digital Passive Infrared (PIR) technology that is tuned for walking size motion while preventing false
tripping from the environment. The integrated photocell enables additional energy savings during daytime periods when there is sufficient daylight. Optimize
sensor coverage by either selecting PIR or PIRH option. PIR option comes with a sensor lens that is optimized to provide maximum coverage for mounting
heights between 8-15ft, while PIRH is optimized for 15-40ft mounting height.
Control / Sensor Options
Motion/Ambient Sensor (PIR_, PIRH_)
nLight® AIR is a wireless lighting controls platform that allows for seamless integration of both indoor and outdoor luminaires. Five-tier security architecture, 900
MHz wireless communication and app (CLAIRITY™ Pro) based configurability combined together make nLight® AIR a secure, reliable and easy to use platform.
Networked Control (NLTAIR2)
HIGH VIEW
0 ft
15
0 m
4.6
30 24 18 12 6 0 ft 6 12 18 24 30
9.2 7.4 5.4 3.6 1.8 0 m 1.8 3.6 5.4 7.4 9.2
30
24
18
12
6
0 ft
6
12
18
24
30
9.2
7.4
5.4
3.6
1.8
0 m
1.8
3.6
5.4
7.4
9.2
LOW VIEW
0 ft
9
0 m
2.7
18 15 12 9 6 3 0 ft 3 6 9 12 15 18
5.4 4.6 3.6 2.7 1.8 0.9 0 m 0.9 1.8 2.7 3.6 4.6 5.4
18
15
12
9
6
3
0 ft
3
6
9
12
15
18
5.5
4.6
3.7
2.7
1.8
0.9
0 m
0.9
1.8
2.7
3.7
4.6
5.5
PIR
PIRH
TOP VIEW
20
10
0 ft
10
20
6.1
3
0 m
3
6.1
20 0 ft 20
6.1 0 m 6.1
SIDE VIEW
0 ft
10
20
30
40
0 m
3
6.1
9.1
12.2
TOP VIEW
20
10
0 ft
10
20
6.1
3
0 m
3
6.1
20 0 ft 20
6.1 0 m 6.1
SIDE VIEW
0 ft
10
20
30
40
0 m
3
6.1
9.1
12.2
Option Dim Level High Level
(when triggered
Photocell
Operation
Motion Time
Delay
Ramp-down
Time
Ramp-up
Time
PIR or PIRH Motion - 3V (37% of full output)
Photocell - 0V (turned off) 10V (100% output) Enabled @ 5fc 5 min 5 min Motion - 3 sec
Photocell - 45 sec
PIR1FC3V, PIRH1FC3V Motion - 3V (37% of full output)
Photocell - 0V (turned off) 10V (100% output) Enabled @ 1fc 5 min 5 min Motion - 3 sec
Photocell - 45 sec
NLTAIR2 PIR, NLTAIR2 PIRH
(out of box)
Motion - 3V (37% of full output)
Photocell - 0V (turned off) 10V (100% output) Enabled @ 5fc 7.5 min 5 min Motion - 3 sec
Photocell - 45 sec
• NLTAIREM2 devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-
sensed (NPS) broadcast is received at least every 8 seconds.
• Using the CLAIRITY+ mobile app, NLTAIREM2 devices must be associated with a group that includes a normal power sensing
device to receive NPS broadcasts.
• The non-emergency devices, NLTAIR2 PIR and NLTAIR2 PIRH, with version 3.4 or later firmware can be used for normal power
sensing.
UL 924 Response – nLight AIR Devices with EM Option
Page 160 of 161
1 Acuity Way • Decatur, GA 30035 • Phone: 1-800-705-SERV (7378) • www.lithonia.com
© 2019-2026 Acuity Brands Lighting, Inc. All rights reserved.
WDGE2 LED
Rev. 07/06/26
COMMERCIAL OUTDOOR
FEATURES & SPECIFICATIONS
INTENDED USE
Common architectural look, with clean rectilinear shape, of the WDGE LED was designed to
blend with any type of construction, whether it be tilt-up, frame or brick. Applications include
commercial offices, warehouses, hospitals, schools, malls, restaurants, and other commercial
buildings.
CONSTRUCTION
The single-piece die-cast aluminum housing integrates secondary heat sinks to optimize
thermal transfer from the internal light engine heat sinks and promote long life. The driver
is mounted in direct contact with the casting for a low operating temperature and long life.
The die-cast door frame is fully gasketed with a one-piece solid silicone gasket to keep out
moisture and dust, providing an IP66 rating for the luminaire.
FINISH
Exterior painted parts are protected by a zinc-infused Super Durable TGIC thermoset powder
coat finish that provides superior resistance to corrosion and weathering. A tightly controlled
multi-stage process ensures a 3 mils thickness for a finish that can withstand extreme climate
changes without cracking or peeling. Standard Super Durable colors include dark bronze,
black, natural aluminum, sandstone and white. Available in textured and non-textured
finishes. COASTAL CONSTRUCTION (CCE) Optional corrosion resistant construction is
engineered with added corrosion protection in materials and/or pre-treatment of base
material under super durable paint. Provides additional corrosion protection for applications
near coastal areas. Finish is salt spray tested to over 5,000 hours per ASTM B117 with scribe
rating of 10. Additional lead-times may apply.
OPTICS
Well crafted reflector optics allow the light engine to be recessed within the luminaire,
providing visual comfort, superior distribution, uniformity, and spacing in wall-mount
applications. The WDGE LED has zero uplight and qualifies as a Nighttime Friendly™
product, meaning it is consistent with the LEED® and Green Globes™ criteria for eliminating
wasteful uplight.
ELECTRICAL
Light engine consists of high-efficacy LEDs mounted to metal-core circuit boards to maximize
heat dissipation and promote long life (up to L91/100,000 hours at 25°C). The electronic driver
has a power factor of >90%, THD <20%. Luminaire comes with built in 6kV surge protection,
which meets a minimum Category C low exposure (per ANSI/IEEE C62.41.2). Fixture ships
standard with 0-10v dimmable driver.
INSTALLATION
A universal mounting plate with integral mounting support arms allows the fixture to hinge
down for easy access while making wiring connections. The 3/8” Architectural Wall Spacer
(AWS) can be used to create a floating appearance or to accommodate small imperfections
in the wall surface. The ICW option can be used to mount the luminaire inverted for indirect
lighting in dry and damp locations. Design can withstand up to a 1.5 G vibration load rating
per ANSI C136.31.
LISTINGS
CSA certified to U.S. and Canadian standards. Luminaire is IP66 rated. PIR options are
rated for wet location. Rated for -40°C minimum ambient. DesignLights Consortium® (DLC)
Premium qualified product and DLC qualified product. Not all versions of this product may
be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List
at www.designlights.org/QPL to confirm which versions are qualified. International Dark-Sky
Association (IDA) Fixture Seal of Approval (FSA) is available for all products on this page
utilizing 2700K and 3000K color temperature only and SRM mounting only.
GOVERNMENT PROCUREMENT
BAA – Buy American Act: This product is available in a version that qualifies as a domestic
end product under the Buy American Act as implemented in the FAR and DFARS.
BABA – Build America Buy America: This product is available in a version that qualifies as
produced in the United States under the definitions of the Build America, Buy America Act,
as implemented by 2 C.F .R. Part 184 and other agency implementing regulations, including
Department of Transportation regulations.
Please refer to www.acuitybrands.com/resources/buy-american for additional information.
WARRANTY
5-year limited warranty. This is the only warranty provided and no other statements in this
specification sheet create any warranty of any kind. All other express and implied warranties
are disclaimed. Complete warranty terms located at:
www.acuitybrands.com/support/warranty/terms-and-conditions
Note: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.
Mounting, Options & Accessories
D = 7"
H = 11"
W = 11.5"
NLTAIR2 PIR – nLight AIR
Motion/Ambient Sensor
D = 1.75"
H = 9"
W = 11.5"
PBBW – Surface-Mounted Back Box
Use when there is no junction box available.
D = 0.38"
H = 4.4"
W = 7.5"
AWS – 3/8inch Architectural Wall Spacer
Page 161 of 161
Source: City of Fort Atkinson website. First collected Oct 8, 2026.