Plan Commission Agenda Packet 10/5/26
City of Eau Claire · Eau Claire County · meeting of Oct 5, 2026 · Agenda packets
Open the original document More from City of Eau Claire
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
James Erickson
Plan Commission Agenda
City Hall Council Chambers
203 S. Farwell Street, Eau Claire, WI 54701
October 5, 2026, 6:00 PM
1. Call to Order
2. Roll Call
3. Open public comment period for items that do not appear on this agenda
Consent Agenda
4. A. Approval of September 14, 2026, Plan Commission minutes
Regular Agenda
5. Public Hearing – For Recommendation to City Council
Rezoning (Z-1770-26)
Request: To recommend approval to rezone properties from CC-P to CC
Applicant: Real Land Surveying
Location: Sculy Drive
6. Public Hearing – For Recommendation to City Council
Rezoning (Z-1769-26)
Request: To recommend approval to rezone properties from UC to CC
Applicant: Mayo Clinic, iHeart Media and City of Eau Claire
Location: 575, 619 & 809 Cameron Street
7. Public Discussion – For Consideration by the Plan Commission
Site Plan (SP-2612) – Industrial Building
Request: To consider a site plan for an industrial building
Applicant: Advanced Engineering Concepts
Location: 6235 Venture Drive
8. Public Discussion – 2027 Plan Commission Schedule
9. Future Agenda Items and Announcements
10. Adjournment
If you have any questions concerning any of the Plan Commission items, please call the Department of Community Development at 715-
839-4914. This notice is given in accordance with the provisions of Subchapter V of Chapter 19 of the Wisconsin Statutes. Notice is hereby
given that members of the City Council may be present at the foregoing meeting to gather information about a subject over which they
have decision-making responsibility. This constitutes a meeting of the City Council pursuant to State ex rel. Badke v. Greendale Village Bd.,
173 Wis.2d 553, 494 N.W.2d 408 (1993) and must be noticed as such, although the Council will not take any formal action at this meeting.
In order to accommodate the participation of persons with special needs at this meeting, the City will provide the services of a sign
language interpreter or make other reasonable accommodations on request. To make such a request, please notify the City at 715-839-
4902 at least 2 days prior to the meeting.
________________________________
James Erickson, Chairperson
c: News Media
1
DRAFT-NOT APPROVED
Plan Commission Minutes
September 14, 2026 at 6:00 p.m.
City Hall Council Chambers
Commission Members Present: Brewster, Erickson, Guettinger, Holzman, Lawson, Lenard, Reed,
Wolfgram
Staff Members Present: Noel
1. Call to Order – Chair Erickson called the meeting to order at 6:00 p.m.
2. Roll Call – Chair Erickson called roll and a quorum was present of eight members.
3. Open public comment period for items that do not appear on this agenda
None one spoke during the open comment period.
Consent Agenda
4. A. Approval of August 31, 2026, Plan Commission minutes
B. Final Plat of Linden Hills
Motion by Commissioner Brewster to approve the consent agenda. Second by Commissioner
Wolfgram and the motion passed unanimously.
5. Future Agenda Items and Announcement
Noel reminded the commission that on September 22nd there will be a community kickoff
meeting for the Comprehensive Plan update at the library.
6. Adjournment
The commission adjourned at 6:05 p.m.
_________________________
Josh Zeug, Secretary
2
Plan Commission
10/5/26 Agenda Items
#1-4A. are Administrative Items
#6. Z-1769-26
#5. Z-1770-26
#7. SP-2612
3
City of Eau Claire
Staff Report
Z-1770-26 - Page 1
Agenda Item: To recommend approval of the rezoning of property from CC-P – Corridor Commercial
with a Planned Development Overlay to CC – Corridor Commercial along the south side of Sculy Drive.
Development Type: Zoning Map Amendment
File Number: Z-1770-26
Completeness Date: 9/10/2026
Plan Commission: 10/5/2026
City Council: 10/12/2026
Owner: KEBB CI EC LLC
Applicant: Real Land Surveying
Address: Sculy Drive
Legal Description: Lots 1 & 2 of CSM #4034
Present Zone: CC-P – Corridor Commercial with a
Planned Development Overlay
Present Use: Vacant with a hotel under
construction
Present Land Use Map: Commercial
Proposed Zone: CC – Corridor Commercial
Proposed Use: Commercial
Proposed Land Use Map: Same
Project Analysis
Real Land Surveying, on behalf of KEBB CI EC LLC, has requested to rezone property from CC-P – Corridor
Commercial with a Planned Development to straight CC - Corridor Commercial to remove the existing
planned development. These properties are two of the remaining pieces of the Southfield Park of
Commerce General Development Plan (Z-1387-07) from 2007 that laid out four quadrants of
development, with the subject properties being within the 31.5 acre “Southfield Retail Center”
quadrant.
The narrative notes that the 5.11-acre project area is divided into two sites through CSM #4039. Lot 1 is
2.35 acres and has a hotel under construction on it, Lot 2 is 2.76 acres and is currently vacant. The
applicant specifically does not declare a specific use of land as being the impetus of the proposed
change and note that their desire is to remove the existing planned development. By removing the
planned development, any new projects would be required to follow the standards of the new LDO and
any future site plans would be administratively approved, rather than approved at the Plan Commission.
Section 17.12.23 of the LDO states that the proposed rezoning must align with the Planned/Future Land
Use Map from the Comprehensive Plan. This area is designated as Commercial on the future land use
map, this zoning change would align with that designation. This request will be reviewed by Council at
their October 12th meeting.
Recommendation
The CC rezoning request meets the LDO criteria in 17.12.23. It is consistent with the Comprehensive
Plan’s Planned Land Use Map of commercial, is suitable and compatible for commercial uses, will not
generate negative impacts on adjacent properties, nor impair health and safety. Staff recommends
approval.
4
0 540 1080270
Feet
0000
5005
0000
0000
6440
6437
0000
0000
6375
O L D T O W N
H
A
L L
R
D
C
E
M
E
T
E
R
Y
L
N
I94
U
S
H
I
G
H
W
A
Y
5
3
SCULY DR
µ
Subject Properties
Notification Area
City Limits
Notification Map
Agenda Item: Z-1770-26
Address: 6375 Sculy Rd and a property at the East
Corner of the intersection of US HWY 53 & Sculy Rd
´
5
0 650 1300325
Feet
4205
0000
5061
5005
0000
0000
6440
6437
0000
0000
6375
P
CC
P
P
CC
CC
CC
CC
MR
O L D T O W N H A L L
R
D
I94
U
S
H
I
G
H
W
A
Y
5
3
C E M E T E R Y L N
S
C
U
L
Y
D
R
µ
Subject Properties
City Limits
Zoning Map
Agenda Item: Z-1770-26
´
6
0 650 1300325
Feet
4205
0000
5061
5005
0000
0000
6440
6437
0000
0000
6375
O L D T O W N H A L L
R
D
I94
U
S
H
I
G
H
W
A
Y
5
3
C E M E T E R Y L N
S
C
U
L
Y
D
R
µ
Medium & High Density
Housing
Commercial
Public Facility
Park
Subject Properties
City Limits
Future Land Use Map
Agenda Item: Z-1770-26
´
7
ORDINANCE
ORDINANCE AMENDING THE ZONING MAP OF THE CITY OF EAU CLAIRE.
THE CITY COUNCIL OF THE CITY OF EAU CLAIRE DO ORDAIN AS FOLLOWS:
That the Official Zoning Map of the City of Eau Claire, Wisconsin, is hereby amended by
rezoning the following described property:
Parcel Number: 15-7005C & 15-7005F
Address: 6375 Sculy Drive & unaddressed lot
From
CC-P – Corridor Commercial Planned Development Overlay
to
CC – Corridor Commercial District
as shown on Planning File No. Z-1770-26, on file in the office of the Department of Community
Development.
All provisions of the Land Development Ordinance now or thereafter adopted, and all regulations
now existing or hereafter adopted by the City of Eau Claire connected with or related to shall
apply to said changed districts, and the Zoning Map adopted by Section 17.01.02 of the Eau Claire
Land Development Ordinance shall thereafter be amended in accordance with this ordinance. A
copy of which is on file in the office of Community Development and open to public inspection
during normal business hours, is hereby approved or approved with conditions, as per Section
17.12.23 of the Eau Claire Land Development Ordinance.
(SEAL)
President Jeremy E. Gragert
(SEAL)
City Manager David A. Solberg
(ATTESTED)
City Clerk Nicholas L. Koerner
First Reading
Final Reading
Adopted
Published
08/25/2026
Real Land Surveying
1356 International Drive
Eau Claire, WI 54701
(715) 514-4116
Sculy Drive Rezone
The 5.11-acre project site is located along the south side of Sculy Drive, with one of the lots
having frontage along State Highway 53. The 5.11 acres is currently divided into two lots via CSM, Lot 1
is 2.35 acres & Lot 2 is 2.76 acres. Both lots are currently zoned CC-P. Lot 2 is vacant, while Lot 1 is
currently amid construction of a hotel.
This rezone request is to simply remove the PLANNED DEVELOPMENT feature from the two lots.
The base CC zoning will remain unchanged. The rezone request will include all of Lots 1 & 2 of CSM
#4034.
Jeremy Skaw, P.L.S.
Field Supervisor
715.514.4116 Office
715.895.8211 Direct
715.225.4572 Mobile
www.rlswi.com
8
9
10
City of Eau Claire, WI
Addresses
Parcel Numbers
PlannedDev
City Zoning
NSR - Non-Sewered Residential
GR - General Residential
NR - Neighborhood Residential
MR - Mixed Residential
UR - Urban Residential
NC - Neighborhood Commercial
CC - Corridor Commercial
UC - Urban Commercial
DT - Downtown
LI - Light Industrial
HI - Heavy Industrial
P - Public
Surrounding Counties
Eau Claire
Chippewa
Dunn
Centerline_Citylimits_3Mile
Interstate
US Highways
State Roads
Ramps
RAMP
Ramp
RAMP US HWY
Major Arterial
Minor Arterial
Collector
Local
Private Drive
Service
Other
Railroads
11
City of Eau Claire
Staff Report
Z-1769-26 - Page 1
Agenda Item: To recommend approval for rezoning properties from UC to CC located at 575, 619 and
809 Cameron Street along Half Moon Lake.
Development Type: Rezoning
File Number: Z-1769-26
Completeness Date: 8/5/26
Waterways & Parks Commission: 9/23/26
Plan Commission: 10/5/26
City Council: 10/12/26
Owners: Mayo Clinic & Capstar Radio Operating
CO & City of Eau Claire
Applicant: Ayres Associates
Address: 575, 619 and 809 Cameron Street
Present Zone(s): UC – Urban Commercial
Present Use(s): Commercial, Parking lot, and
Vacant
Present Land Use Map: Commercial
Proposed Zone(s): CC – Corridor Commercial
Proposed Use(s): Commercial and future
development
Proposed Land Use Map: Same
Zoning Map Change: The request is reviewed using 17.12.23 of the Land Development Ordinance (LDO).
Project Analysis
Mayo Clinic along with Capstar Radio Operating CO and the City of Eau Claire have submitted a rezoning
request from UC to CC located at 575, 619 and 809 Cameron Street along Half Moon Lake. The parcels
are zoned UC – Urban Commercial and are approximately 9.7 acres in size. This area is along Half Moon
Lake. The area includes the Mayo Clinic parking lot, iHeart Media Eau Claire and a vacant City lot.
The applicant’s narrative notes the existing UC zoning is intended for pedestrian-oriented, neighborhood
scale spaces, but the scale of their proposed childcare facility aligns better with CC standards. This area
is more auto focused and transitional from the downtown. The proposed rezoning would strengthen the
area for this type of commercial use. The existing iHeart Media building also aligns with CC zoning given
its one-story height and deeper setbacks. The Comprehensive Plan’s Trail System Plan requires a trail,
which will increase connectivity and directly benefit people using the daycare, sites and lake. A future
trail was shown in a 2005 site plan approval for Mayo’s large parking lot but was never built.
The Waterways and Parks and Urban Foresty Commission recommended approval at their September
23rd meeting. The rezoning recommendations will be reviewed by the City Council on October 10th.
Recommendation
The CC rezoning request meets the LDO criteria in 17.12.23. It is consistent with the Comprehensive
Plan’s Planned Land Use Map of commercial, is suitable and compatible for commercial uses, will not
generate negative impacts on adjacent properties, nor impair health and safety. Staff recommends
approval subject to the following condition:
1. A future public trail along the sites shall meet 17.08.09 B. in the LDO.
12
ORDINANCE
ORDINANCE AMENDING THE ZONING MAP OF THE CITY OF EAU CLAIRE.
THE CITY COUNCIL OF THE CITY OF EAU CLAIRE DO ORDAIN AS FOLLOWS:
That the Official Zoning Map of the City of Eau Claire, Wisconsin, is hereby amended by
rezoning the following described property:
Parcel Number: 09-1012, 09-1014, 09-1016
Address: 575 Cameron St., 619 Cameron St., 809 Cameron St.
From
UC – Urban Commercial District & UC – P Planned Development
to
CC – Corridor Commercial
as shown on Planning File No. Z-1769-26, on file in the office of the Department of Community
Development.
All provisions of the Land Development Ordinance now or thereafter adopted, and all regulations
now existing or hereafter adopted by the City of Eau Claire connected with or related to shall
apply to said changed districts, and the Zoning Map adopted by Section 17.01.02 of the Eau Claire
Land Development Ordinance shall thereafter be amended in accordance with this ordinance. A
copy of which is on file in the office of Community Development and open to public inspection
during normal business hours, is hereby approved or approved with conditions, as per Section
17.12.23 of the Eau Claire Land Development Ordinance.
(SEAL)
President Jeremy E. Gragert
(SEAL)
City Manager David A. Solberg
(ATTESTED)
City Clerk Nicholas L. Koerner
First Reading
Final Reading
Adopted
Published
13
0 625 1250312.5
Feet
0000
519
596
560
0000
1832
1914
1515
1812
610
1726
0000
1732
460
714
725
620
0000
722
806
814
1722
620
816
528
710
1608
1830
726
1818
830
1728
809
1725
1809
1726
811
1603
1812
610
1807
824
705
527
1828
1811
1820
511
1827
1523
1817
818
702
1907
550
1617
1906
810
714
616
1720
1724
1704
1705
1706
1621
1906
1614
602
531
1910
1911
1622
1812
514
1819
1823
1823
1813
1818
1808
1913
1806
510
1804
444456
1824
1809
1818
440
1819
1714
1721
1725
424
1711
1715
450
1710
434
428
1529
420
1707
1721
606
1713
815
1714
530
1537
1831
1821
1611
1607
1722
604
406
1710
534
405
548
514
429
1533
320322
1719
1821
1827
1817
512
1811
313
1715
1720
1500
1506
602
600
575
813
809
1717
615
1706
619
0000
615
1412
709
0000
0000
323
1709
CAMERON ST
W
M
A
D
I
S
O
N
S
T µ
Notification Area
Subject Property
Notification Map
Agenda Item: Z-1769-26
Address: 575-809 Cameron St.
´
14
0 625 1250312.5
Feet
0000
519
596
560
0000
1832
1914
1515
1812
610
1726
0000
1732
714
725
620
0000
722
806
814
1722
620
816
528
710
1608
1830
726
1818
830
1728
809
1725
1809
1726
811
1603
1812
610
1807
824
705
527
1828
1811
1820
511
1827
1523
1817
818
702
1907
550
1617
1906
714
616
1720
1724
1704
1705
1706
1906
1614
602
531
1911
1622
1812
514
1819
1823
1813
1818
1806
510
1804
1803
456
1824
1818
1714
1710
428
1707
1721
606
1713
815
1714
530
1537
1831
1821
1607
1722
604
406
1710
534
405
548
514
429
1719
313
1715
1720
1500
1506
602
600
575
813
809
1717
615
1706
619
0000
615
1412
709
0000
0000
323
1709
P
LI
LI
LI
LI
P
MR
MR
NR
NR
UC
NR
MR
NR
MR
NR
NR
MR
P
NR
NR
NR
MR
MR
NR
MR
NR
NR
MR
NR
NR
NR
MR
NR
NR
NR
MR
NR
NR
MR
MR
MR
NR
NR
MR
MR
MR
MR
UR
MR
NR
MR
NR
NR
MR
MR
NR
NR
NR
NR
MR
NR
NR
NR
NR NR
NR
NR
NR
MR
MR
NR
NR
NR
NR
MR
NR
NR
NR
NR
MR
NR
NR
MR
MR
NR
MR
NR
MR
MR
NR
NR
MR
NR
NR
NR
NR
MR
NR
NR
MR
NR
MR
NR
MR
NR
NR
MR
NR
NR
MR
MR
NR
MR
MR
NR
NR
NR
MR
MR
NR
MR
MR
MR
UC
MR
NR
MR
MR
MR
MR
MR
MR
MR
MR
MR
MR
P
UC
P
UC
UC
P
UC
MR
MR
P
UC
P
P
UC
NR
P
P
MR
MR
PLATT ST
4TH
ST
6TH ST
7TH ST
8TH ST
CAMERON ST
E
H
A
L
F
M
O
O
N
D
R
RANDALL ST
P
A
V
I L
I O
N
D
R
CAMERON TRL
KENDALL ST
MAXON ST
CHARLES
ST
W MADISON ST
W
H
A L F
M
O
O
N
D R
µ
Subject Properties
Zoning Map
Agenda Item: Z-1769-26
Address: 575, 619, and 809 Cameron Street
´
15
715.834.3161 | 3433 Oakwood Hills Parkway | Eau Claire, WI 54701-7698
www.AyresAssociates.com
Project: 23-2062.00 File: C:\ACC\ACCDocs\Ayres Engineering Services\MCHS Eau Claire Childcare Facility\Project Files\1.Project
Management\Regulatory\City of Eau Claire Rezoning\Rezoning Narrative.docx
July 21, 2026
Aaron White,
Community Development Director
Eau Claire, WI 54702
Re: Mayo Clinic Health Systems Childcare Facility
City of Eau Claire
Dear Mr. White,
Ayres Associates has prepared this rezoning petition for the property located at 575
Cameron Street for Mayo Clinic Health System Northwest Wisconsin Region Inc. (MCHS).
In conjunction with this rezoning petition it has been requested to petition for rezoning of
the properties at 619 and 809 Cameron Street.
The proposed rezoning would align the property with the Corridor Commercial (CC)
district, which is intended to support a variety of commercial and service-oriented uses
that serve surrounding neighborhoods and the broader community.
Property Summary
The subject property is a 6.20-acre (approximately 270,000 square feet) parcel currently
uses as a parking lot. Located at 575 Cameron Street, the land is identified as Parcel
1822122709180050021 and is owned by my MCHS. Legally, the tract is described as “a
portion of Government Lot 5, Section 18-27-9, beginning on the center line of Cameron
Street at a point 312 feet East of the West line of said Government Lot 5, thence running
East 956.75 feet, thence South at a right angle to Cameron Street 133 feet, thence South
56 degrees 22 minutes West 725 feet more or less to the shore of Half Moon Lake, thence
Northwesterly along the shore line 371.25 feet more or less to a point due South of the
point of beginning, and thence North 470 feet more or less to the point of beginning,
excluding the East 300 feet thereof and subject to existing easements.”
The other requested properties are listed below. There is no redevelopment planned at
this time for the parcels listed.
Parcel 1822122709180050022
Parcel 1822122709180060029
Rezoning Request & Justification
It is desired to rezone the property from Urban Commercial (UC) to Corridor Commercial
(CC). While the current UC zoning is intended for pedestrian-oriented, neighborhood scale
spaces, the scale of the proposed childcare facility aligns far better with the standards of
the CC zone. Transitioning to Corridor Commercial allows the area to function as a highly
visible and attractive facility that can safely handle the heavier traffic. Furthermore, the CC
16
Aaron White
July 21, 2026
Page 2 of 2
715.834-3161 | 3433 Oakwood Hills Parkway | Eau Claire, WI 54701-7698
www.AyresAssociates.com
Project: 23-2062.00 File: C:\ACC\ACCDocs\Ayres Engineering Services\MCHS Eau Claire Childcare Facility\Project Files\1.Project
Management\Regulatory\City of Eau Claire Rezoning\Rezoning Narrative.docx
classification provides the necessary flexibility for a larger project while utilizing its major
roadway to create convenience and access as well as minimizing local traffic congestion.
The proposed rezoning to CC would:
Strengthen the property's commercial development potential.
Better align the property with surrounding commercial uses and development patterns (if
applicable).
Support retail, office, restaurant, and service-oriented uses.
Shift the focus from mixed-use and residential-oriented development toward commercial
activity.
Provide a zoning designation that is consistent with the intent of the Community
Commercial district.
Project Schedule
The proposed schedule for the transition of the property from its current state to the active
childcare facility is planned for the near future. Demolition of the existing lot and
construction of the facility and parking lot are targeted to align with a planned completion
and opening in Q3 of 2027.
Maps
We have attached an existing conditions exhibit as well as a concept exhibit of the facility
and site for your reference.
Sincerely,
Ayres Associates Inc
Brian Lambert, PE
Project Manager
Direct: 715.831.7639
LambertB@AyresAssociates.com
17
Ayres Associates | 3433 Oakwood Hills Parkway, Eau Claire, WI 54701 | 715.834.3161 | www.AyresAssociates.com | # 23-xxxx
Rezoning Petition - Cameron St, Eau Claire | Parcels
File: C:\Users\lambertb\AppData\Roaming\Bluebeam Software\Revu\20\Templates\Ayres Exhibit 11x17.pdf | Plot Date: 09/01/2020
7/20/2026
1
2
3
Redevelopment Parcel
18
19
20
City of Eau Claire
Staff Report
SP-2607 - Page 1
Agenda Item: To approve the site plan for an industrial building located at 6325 Venture Drive.
Development Type: Major Development
File Number: SP-2612
Completeness Date: 8/2/026
Plan Commission: 10/5/2026
Project Name: OEM Fabricators Inc
Owner: Same
Applicants: AEC
Address: 6325 Venture Drive
Legal Description: LOT 4 CSM 6205 REC V 31 P 359
DOC 965343 LOC IN SW1/4 SEC 36-28-10
Present Zone(s): LI – Planned Development
Present Use(s): Vacant
Present Land Use Map: Industrial
Proposed Zone(s): Same
Proposed Use(s): Industrial Building
Proposed Land Use Map: Same
Zoning District Summary: The subject site is zoned LI – Planned Development and is reviewed per the
dimensional standards within 17.02.03 H. of the Land Development Ordinance (LDO) and the General
Development Plan (GDP) of the Gateway Northwest Business Park – Phase II, Amended 2019.
Project Analysis
Advanced Engineering Concepts, on behalf of OEM Fabricators Inc, have submitted a site plan for a
building located at 6325 Venture Drive. This project is within the Planned Development for the Gateway
Industrial Park. The zoning of the property is Light Industrial with a Planned Development (PD) overlay. A
condition of the PD states that all site plans need to be reviewed and approved by the Plan Commission.
This parcel of land was created by a CSM and the property is approximately 10 acres in size.
The proposed site plan shows an approximately 33,150 square feet industrial building. The building
elevations show the building materials and the rooftop mechanical equipment are fully screened, as
proposed. The access into the site is from the proposed Venture Drive extension. The site plan shows
approximately 36 parking stalls to the south of the building. The landscape plan shows proposed street
trees and foundation plantings.
Recommendation
Based on this analysis, the Plan Commission may approve the site plan with the following conditions:
1. Meet the conditions of the Engineering Report, including submitting an administrative
adjustment application for the wider 40’ driveway.
2. Screen any trash dumpsters that are not located inside the building. A fully opaque fence from
the front yard view is acceptable.
3. Any proposed access gravel drives shall be hard surfaced per the GDP.
4. A proposed lighting plan should be submitted at a later date meeting the LDO.
5. Proposed signs should meet the city code section 17.09 and are reviewed with a sign permit.
6. A building permit should be issued prior to the start of construction on the site.
21
Engineering Analysis & Report
Engineering Department
SUBJECT: SP-2612, Project Spectacle – OEM
DATE: September 28, 2026
BY: Al Rinka, P.E.
Deputy City Engineer
The proposed site plan is located north of County Line Road and east of Venture Drive. The
following comments are based on materials received by the City of Eau Claire
Engineering Department on August 25, 2026.
Grading and Drainage: The site is tributary to Sherman Creek via a northwesterly regional
conveyance.
The regional stormwater infiltration facility will meet the peak rate runoff control and infiltration
requirements for the site. On-site runoff water quality BMP’s may be required for pretreatment
due to the industrial operations of the site.
Public Utilities: Water and sewer service is being constructed for this site as part of the
Venture Drive extension north of County Line Road. Record dimensions of public facilities can be
obtained by calling the Engineering Department. Utility connections may require a work in the
right-of-way permit and a plumbing permit.
Fire sprinkler designs should be based on fire hydrant flow tests. Contact the Water Utility at
715-839-5045 to obtain fire hydrant flow test data or to request a flow test.
Traffic: The traffic generated by the proposed improvements should not adversely impact
traffic flow in the area.
Two driveway accesses are shown for this project, one 27-foot-wide access and another
40-foot-wide access. Driveway widths more than 30 feet will require an administrative adjustment
(section 17.12.04(1)(i)); Section 17.08.07(C) “Driveway Dimensions” lists the criteria allowing an
administrative adjustment of the 30-foot requirement if one of the following is met:
1. A wider driveway is needed for the turning movement of large trucks,
2. A wider driveway is warranted by the volume of entering or exiting traffic, or
3. For other good reason directly related to traffic control and safety.
Transit: The proposed project is not likely to impact Transit. There is no bus service within
one mile of this project location.
Recommended Conditions:
1. City of Eau Claire Engineering Department approval of drainage calculations and
drainage plan.
2. Submit an Administrative Adjustment for review of the 40-foot-wide driveway. Provide updated
truck turning movements exhibiting the entering and exiting movements through the site.
cc: William Youngberg, Inspections & Zoning
Michael Mancl, Utility Supervisor
22
0 900 1800450
Feet
0000
5503
2537 5845
2218
0000
2209
6120 0000
0000
0000
6480
6465
6325
6105
0000
COUNTY LINE RD
VENTURE DR
µ
City Limits
SP_2612
Aerial Map
Agenda Item: SP-2612
´
23
Advanced Engineering Concepts
1360 International Drive
Eau Claire, WI 54701
Office 715.552.0330
www.aec.engineering
Project Spectacle - OEM
Site Plan Narrative
OEM Fabricators Inc
Eau Claire, WI
OEM Fabricators is proposing to develop the 10-acre Lot 4 of Gateway Northwest Business Park with
one (1) 33,000 sq. ft. warehouse. The parcel is located on Venture Drive in the City of Eau Claire. The
overall site will be approximately 21% impervious.
The existing site is vacant with scattered trees along the east edge of the property. The adjacent land
uses are as follows: North: Vacant parcel (LI), East: Vacant Parcel (LI), South: Vacant parcel (LI),
West: Venture Drive.
Setbacks on the site will be 25-feet in the front and 10-feet on the sides and 25-feet rear. The total site
will have 36 parking stalls. The proposed development will be 21% impervious and 79% green space.
The parking lot will have two access points from Venture Drive via one 40-foot-wide driveway apron
and one 27-foot-wide driveway apron. The 40-foot-wide driveway is needed for efficient truck
movements.
The building façade will be premium lap or metal siding and vinyl clad windows. Landscaping will be
done in accordance with the City of Eau Claire standards using a combination of trees, shrubs, and
grasses planted around the perimeter of the building and throughout the overall site. Wall pack lighting
will be placed on the proposed building at all entrances. Any additional lighting shall be downcast and in
accordance with City of Eau Claire standards. Mechanical equipment will be kept to the rear of the
building and will be screened by plantings or shrubs.
The site will be served by a 6” water service connecting to watermain stub, 6” sanitary sewer service
connecting to sanitary stub. There is electric and utilities available within the adjacent right-of-way.
The site’s development is treated by a regional facility within Venture Drive project for water quality
and infiltration. Hydrocad and winslamm models provided to show being under the handled design.
Construction is expected in the Fall of 2026 with the utility work, then the building being built shortly
after in a continuous and steady fashion until the site is built-out in the summer of 2027.
24
SHEET SCHEDULE
DESCRIPTION SHEET
NO.
1
PROJECT SPECTACLE - OEM
DURAND BUILDERS
6325 VENTURE DRIVE
EAU CLAIRE, WI 54703
PROJECT LOCATION
Know what'sbelow.
before you dig.Call
R
TITLE SHEET
EXISTING CONDITIONS & DEMOLITION PLAN
SITE & CONCEPTUAL LANDSCAPE PLAN
UTILITY PLAN
GRADING PLAN
EROSION CONTROL PLAN
DETAILS
2
3
4
5
6
7
25
Know what'sbelow.
before you dig.Call
R
26
Know what'sbelow.
before you dig.Call
R
27
Know what'sbelow.
before you dig.Call
R
’
’
28
Know what'sbelow.
before you dig.Call
R
29
Know what'sbelow.
before you dig.Call
R
30
OWNER CONTACT CONTRACTOR
COMPANY: DURAND BUILDERS
ADDRESS: P.O.BOX 10
DURAND, WI 54736
PHONE: 715-672-5941
FAX: 715-672-8886
CONTACT: PATRICK RIES
EMAIL: pries@durandbuilders.com
ARCHITECT
COMPANY:GRUBE ARCHITECTS
ADDRESS: STILLWATER, MN
CONTACT: KEVIN L. GRUBE
PHONE:651.303.8155
EMAIL: klgrube@grube-architects.com
STRUCTURAL ENGINEER
COMPANY:OEM FABRICATORS
ADDRESS:300 MCMILLIAN RD
WOODVILLE, WI 54028
CONTACT: JUSTEN WALTON
PHONE:715-716-3181
EMAIL: jwalton@oemfab.com
COMPANY:
ADDRESS:
CONTACT:
PHONE:
EMAIL:
Area Legend
3,220 ft²
3,394.46 ft²
26,605.54 ft²
3,220 ft²
B
26,605.54
ft²
F-2
3,394.46
ft²
S-2
BUILDING CODE: WISCONSIN BUILDING CODE IBC 2021
BUILDING TYPE: 2B
OCCUPANCY AREA
B: 3,220 SQFT
F-2: 26,606 SQFT
S-2: 3,394 SQFT
SQFT TOTAL 33,220 SQFT
ALLOWABLE AREA: UNLIMITED SQFT WITH SPRINKLER
UNLIMITED BUILDING AREA:
IBC 2021: 507.4 SPRINKLED ONE-STORY OF B, F, M OR S OF ANY CONSTRUCTION
SURROUNDED BY 60' PUBLIC WAYS OR YARDS= UNLIMITED AREA PER CODE
OCCUPANCY LOAD:
B: 3,220/150=21.4=22 PERSONS
F-2: 26,606/100=266.1=267 PERSONS
S-2: 3,394/500=6.7=8 PERSONS
PERSONS TOTAL 297 PERSONS
IBC 2021: 1004.5 (EXCEPTION)
WHERE APPROVED BY THE BUILDING OFFICIAL, THE ACTUAL NUMBER OF OCCUPANTS
FOR WHOM EACH OCCUPIED SPACE, FLOOR OR BUILDING IS DESIGNED, ALTHOUGH
LESS THAN THOSE DETERMINED BY CALCULATION, SHALL BE PERMITTED TO BE USED
IN THE DETERMINATION OF THE DESIGN OCCUPANT LOAD.
NOTE SQFT AMOUNT IS WELL ABOVE THE MAX OF 30 EXPECTED EMPLOYEES
OWNER TO GIVE LETTER STATING PERSONS MAX. OF 100
MAXIMUM EXIT DISTANCE: B:300' FT
F-2/ S-2:400'FT
TOILET FACILITIES:
B:100/2=50/25=2 (WORST CASE FOR PLUMBING)
2 EA SEX
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:47 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:47 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
G-101
As indicated
Cover Sheet
KMS
KMS
KMS
Project Spectacle
NEW BUILDING
26PROEM
GATEWAY PARK
Sheet List -G-
Sheet Name Sheet Number
Cover Sheet G-101
General Site Layout G-102
General Info G-103
General Info G-103.1
Sheet List -A-
Sheet Name Sheet Number
Main Level Overview A-101
Main Level Office A-101.1
Main Level Manufacturing A-101.2
Main Level Manuf. callout A-101.3
Ceiling Plan A-103
Elevations A-201
Elevations A-202
Sections A-301
Sections A-302
Door Schedules A-601
Window and Room Schedules A-602
Sheet List -S-
Sheet Name Sheet Number
Structural notes S-100
Foundation Plan S-101
Details S-102
Details S-103
Compressor and office S-104
Roof Plan S-105
SITE LOCATION PER GOOGLE MAP
NORTH
GENERAL NOTES:
1.ALL WORK TO BE DONE IN COMPLIANCE
WITH ALL LOCAL AND STATE BUILDING CODES.
2.DO NOT SCALE DRAWINGS.
3.CONTRACTORS TO VERIFY ALL DIMENSIONS,
SIZES AND CONDITIONS.
4.ALL GRADES, ALL FOUNDATION ELEVATIONS,
STEP CONDITIONS AND FOOTING ELEVATIONS
TO BE VERIFIED BY CONTRACTOR,
5.ALL FINISHES AND MATERIALS TO BE
APPROVED BY OWNER.
6.PROVIDE WOOD BACKER FOR ALL SHELVING,
CABINETRY ,GRAB BARS AND TOILET ROOM
ACCESSORIES
7.HVAC, PLUMBING AND LIGHTING IS DESIGN
BUILD.
8.ALL GRADES, ALL FOUNDATION ELEVATIONS,
STEP CONDITIONS AND FOOTING ELEVATIONS,
TO BE VERIFIED BY CONTRACTOR.
FOUNDATION DROPS AND FOOTING
ELEVATIONS MAY NOT BE ACCURATE FOR
BUILDING SITE
9.ALL DISSIMILAR METALS SHALL BE
PROTECTED FROM ONE ANOTHER WITH
PROPER MEMBRANE TO PREVENT GALVANIC
CORROSION.
No. Description Date
ALTERNATE: 10 TON BRIDGE CRANES.
REQUIRING AN ADDITIONAL 4'-0" FEET
IN ELEVATION, CHANGING THE ROOF
LEVEL TO 130'-0"
31
646'-0"
42'-0"
180'-0"
200'-0"
150'-0"
75'-0"
192'-0"
40'-0"
PROPOSED
BUILDING
33,220 SQFT
PROPOSED PARKING LOT
36 PARKING SPACES SHOWN MAX. 30 EMPLOYEES
35 SPACES MORE THAN COVER ZONING CODE 18.25.15
OF 2 SPACES FOR EACH 3 EMPLOYEES ON THE HIGHEST SHIFT
AND ACCOMMODATES ANY POSSIBLE VISITORS
FUTURE ROAD
50,000 SQFT OF ASPHALT
11,500 SQFT OF GRAVEL
ACCESS ROAD
PROPOSED ROAD
STREET SETBACK
25'-0"
STREET SETBACK
25'-0"
SIDE SETBACK
10'-0"
REAR SETBACK
20'-0"
13,300 SQFT OF CONCRETE
SIDEWALKS,APRONS AND CURB
APPROX.
240'-11 5/8"
BIKE
PARKING
LIGHTING POLES
(5) TO BE VERIFIED
X
DESIGNATED
GREEN SPACE
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
FENCE HERE AND HERE
LOCATIONS APPROX. AND MATERIAL
TO BE VERIFIED
18'-0"
ADA
MONUMENT SIGN
MIN. 15' OFF STREET R/W
8
14
7
7
X X
X
X
X
X X
FENCE FOR
MECHANICAL EQUIPMENT
PROPERTY LINE
PROPERTY LINE
EASEMENT
PROPERTY LINE
PROPERTY LINE R/W
726'-0"
FILTRATION POND SIZE AND LOCATION T.B.V.
ADA
SIGN
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:47 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:47 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
G-102
1" = 50'-0"
General Site Layout
KMS
KMS
KMS
26PROEM
Issue Date
1" = 50'-0"1 Site - Phase 1
N
No. Description Date
SITE PLAN IS FOR GENERAL
LAYOUT PURPOSES AND IS TO BE USED
FOR BUILDING CODE COMPLIANCE PURPOSES ONLY.
REFER TO THE SITE DRAINAGE PLAN AND EROSION
CONTROL PLAN. IF ANY, FOR FINAL SITE DRAINAGE
ELEVATIONS. EROSION CONTROL AND FINAL
BUILDING PLACEMENT ON SITE. SITE DESIGN BY OTHERS.
32
REQUIRED STRUCTURAL TEST AND SPECIAL INSPECTIONS
DESCRIPTION OF WORK IBC SECTION 1705 INSPECTION TESTING
YES NO YES NO
N/A REMARKS
1.1 SPECIAL CASES
2.1 STEEL FABRICATION
2.2 COLD-FORMED STEEL DECK
2.3 OPEN-WEB STEEL JOIST AND GIRDERS
3.0 CONCRETE CONSTRUCTION
3.1 WELDING OF REINFORCING BARS
3.2 MATERIAL TESTS
4.0 MASONRY
5.0 WOOD CONSTRUCTION
5.2 METAL PLATED WOOD TRUSS>60'
5.6 SOILS
5.9 HELICAL PILE FOUDNATION
5.11 FABRICATED ITEMS
5.12 WIND RESISTANCE
5.13 SEISMIC RESISTANCE
International Building Code section 1705 requires that in addition to the inspections required by
section 110, the owner shall employ one or more special inspectors to provide inspections during
construction on the types of work listed under section 1705.
"Special inspection" concerns work requiring observations and judgement and shall be performed
by a structural engineer or designated person under the supervision of the engineer.
"Testing" involves the analysis of materials in accordance with the approved standards and shall
be performed by an independent testing agency. The Contractor shall coordinate the testing and
inspection services in accordance with the progress of the work. The contractor shall provide
sufficient prior notice to the testing or inspection agency of the required work to allow proper
scheduling of personnel. The cost of any re-testing or additional inspections as a result of failed
test and rejected work shall be borne by the contractor.
SPECIAL INSPECTIONS
A-2022 Rear
1
2
3
4
5
6
7
8
9
A B C D E F JC.4 HGD.9 E.9 F.7
7.3
G.9
F.E
F.E
F.E
F.E
F.E
F.E
F.E
F.E
F.E
F.E
F.E
F.E
F.E
PARKING SURFACE
MIN.
5'-0"
ADA VAN ACCESSIBLE
SIGN TO COMPLY WITH WI. CODE.
EXIT
EMERGENCY LIGHTING
FIRE EXTINGUISHER
EGRESS PATH
ACCESSIBLE ROUTE
F.E
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:48 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:48 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
G-103.1
As indicated
General Info
KMS
KMS
KMS
26PROEM
Issue Date
No. Description Date
1/16" = 1'-0"2 Egress plan
3/4" = 1'-0"3 HC PARKING SIGN
33
A-201
A-202
A-2022 Rear
A-201 2 Front
1 Left
1 Right
42'-0" 150'-0"
200'-0"
125'-0" 75'-0"
1
2
3
4
5
6
7
8
9
A B C D E F J
A-101.1
1
A-101.2
1
C.4 HGD.9 E.9 F.7
192'-0"
192'-0"
42'-0" 150'-0"
FUTURE EXPANSION HERE
ASSUME GIRTS AND SHEATHING REMOVED
FUTURE EXPANSION HERE
ASSUME GIRTS AND SHEATHING REMOVED
7.3
G.9
40'-0"
37'-0"13'-0"
66'-0" 15'-0" 14'-6"
21'-0"
15'-6"
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:48 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:48 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
A-101
1/16" = 1'-0"
Main Level Overview
KMS
KMS
KMS
26PROEM
Issue Date
1/16" = 1'-0"1 Level 1 Main Level Overview
N
No. Description Date
34
6
7
8
9
A B C
1
A-301
22'-0" 20'-0"
42'-0"
3'-3" 2'-11" 6'-11" 5'-8" 6'-3" 7" 5'-8" 12'-6" 3'-9" 2'-6" 6'-3" 12'-6" 6'-3"
4'-6 1/8"
10'-0" 12'-0" 2'-6" 3'-0" 14'-6"
3'-3" 9'-10" 10'-7" 1'-11" 21'-11" 27'-6"
COUNTER
6'-0"
66.63 ft²
9'-5 1/8" X 7'-0 13/16"
VESTIBULE
100
CLOSET 7'-0" X 2'-0"
FOR SHOVEL/ ICE MELT/
HANGING COATS ETC.
100A
100B
100C 154.74 ft²
13'-1 1/8" X 11'-9 13/16"
RECEPTION/
WAITING
101
35
8'-4" 13'-6" 20'-2"
14'-9" 2'-2" 4'-11" 20'-2"
159.28 ft²
OFFICE
103
102
103
604.28 ft²
30'-8 13/16" X 19'-7 15/16"
BREAK ROOM/
TRAINING
104
2'-9" 8'-7 1/2"
339.2 ft²
VISITOR
CONFERENCE
105
21" DEEP IT CLOSET
13'-6" X 23'-5"
44.53 ft²
UNISEX
106
5'-8" 2'-3" 2'-1" 4'-8" 5'-6"
105
35
35
35
8'-4" 6'-9" 6'-9" 5'-8" 3'-0" 11'-6"
261.14 ft²
HALLWAY
107
37.39 ft²
STORAGE
108
106
108
107A
107B
168.94 ft²
17'-7 5/16" X 9'-7 1/8"
WOMENS
109
265.8 ft²
MENS
110
539.58 ft²
26'-2 13/16" X 20'-6 13/16"
CUBICLES
111
104
107C
24'-9 1/2" X 9'-1"
94.22 ft²
19'-10 13/16" X 4'-8 13/16"
HALLWAY 2
116
110A
109B 110B
116
9X5
112A
MECHANICAL ITEMS
SPACE T.B.V.
OFFICE SUPPLY STORAGE
25'-0" 25'-0" 25'-0"
22'-0" 20'-0"
42'-0"
35
35
35
CLIMATE CONTROLLED
1'-9"
4'-6 1/8"
7'-0" MIN. ALT ADA
7'-1"
53.93 ft²
8'-0 1/4" X 6'-8 11/16"
JANITOR
114
8X7
COUNTER
11'-9"
4'-1 5/16"
7X7 7X6
114
34
7'-6"X6'-4" 6'-4"X6'-4"
WATER FOUNTAIN
32'-0" 6'-7" 30'-5" 6'-0"
C
D
E
F
D
D
D
D
D
D
E
D
FUTURE EXPANSION HERE
ASSUME GIRTS AND SHEATHING REMOVED
7X6 7X6
7.3
43'-6" 31'-6"
MOP SINK
75'-0"
SIGN IN COUNTER
8X5 8
15'-8"X 10'-2"
14'-0"
5'-0"
C
C
K
K
1'-9" 8'-10" 6'-4 7/8" 11'-0 1/4" 6'-4 7/8"
6'-0"18'-0 3/16"7'-2 13/16"6'-10"4'-11"
1'-8"
1'-4"
10'-0" 10'-2"
1'-10 1/2"
1'-9"
WALL WIDEN AS NEEDED FOR COLUMN
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:48 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:48 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
A-101.1
1/4" = 1'-0"
Main Level Office
KMS
KMS
KMS
26PROEM
Issue Date
1/4" = 1'-0"1 Office - Callout 1
No. Description Date
35
A-201
A-2022Rear
1 Right
1
2
3
4
5
6
7
8
9
B C D E F J
10'-0" 25'-0" 2'-6" 20'-0" 2'-6"2'-0"3'-0" 10'-0" 15'-8" 3'-0" 8'-4" 17'-0" 9'-0" 1'-0"4'-0" 9'-0" 8'-0"
26' JIB
2 TON
MAX HOOK HEIGHT
BUILDING COLUMN ARE STRAIGHT
THAT SUPPORT JIB CRANES
150'-0"
C.4
COLUMN SPACING
10'-0" 25'-0" 25'-0" 15'-0" 27'-0" 27'-0" 21'-0"
10'-0" 25'-0" 20'-0" 20'-0" 25'-0" 25'-0" 25'-0"
150'-0"
25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 21'-0"
H
150'-0"
GD.9 E.9 F.7
200'-0"
25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"
25,685.61 ft²
MANUFACTURING
117
3,302.53 ft²
SHIPPING
118
OFFICE
119
UNISEX
121
BRIDGE CRANE
5 TON
22'-0" HOOK HEIGHT
ALT: 10 TON, 26'-0" HOOK HEIGHT
26' JIB
2 TON
MAX HOOK HEIGHT
26' JIB
2 TON
MAX HOOK HEIGHT
26' JIB
2 TON
MAX HOOK HEIGHT
A-101.3
1
117D
21'-0" 3'-0"
1'-0" 1'-0"
14'-0" 10'-0"
200'-0"
117E
117N
40'-0"
PRESS BREAK
WITH CONTROL PANEL
6'-0" X 15'-0" SHOWN
ISOLATION PAD SIZE T.B.V.
*GAS STORAGE CABINET
AND WELD BOTTLE STORAGE
MUST BE MINIMUM 20' AWAY
FROM WELDING OPERATIONS
AND 35' FROM COMBUSTIBLES
RISER
LOCATION
T.B.V.
26' JIB
2 TON
MAX HOOK HEIGHT
26' JIB
2 TON
MAX HOOK HEIGHT
1
A-302
A
A
A
A
E
A-101.3
3
26' JIB
2 TON
MAX HOOK HEIGHT
26' JIB
2 TON
MAX HOOK HEIGHT
24 HALF LOCKERS
FUTURE EXPANSION HERE
ASSUME GIRTS AND SHEATHING REMOVED
FUTURE EXPANSION HERE
ASSUME GIRTS AND SHEATHING REMOVED
7.3
50HP SCREW
COMPRESSOR
50HP SCREW
COMPRESSOR
117H 117K 117L
OPENING 48" WIDE X 30" TALL
FUTURE
9X10 DOOR117J
RAMP DOWN
26' LONG SHOWN
ALUMINUM SCRAP
STANDARD ROLL-OFF
60K LBS
48" DROP
30" DROP
20' ROLLER BED
2 SUPPORTS,
10'0" O.C. 8,000
LBS TOTAL
DUMPSTERS
FORKLIFT CIRCLE
66'-0" 15'-0" 14'-6" 54'-6"
4 %
G.9
MECH. /
JANITOR
115
74'-6" 15'-6" 60'-0"
117B
117A
117C
APPROX.
20'-0"
APPROX.
42'-0" 42'-0"
SCREEN/ FENCE IN MECHANICAL EQUIPMENT
8' HIGH SOLID LINER PANEL WALLS
6" CONCRETE FLOOR W/ #4 24" O.C. REBAR MAT
26' JIB
2 TON
MAX HOOK HEIGHT
4'-0" 16'-0" 5'-0" 2'-0"3'-0"
40'-0"
50'-0"
4 % APPROX. GROUND
97'-6"
APPROX. GROUND
98'-10 1/2"
STAINLESS SCRAP
STANDARD ROLL-OFF
60K LBS
TRUCK UNLOAD AREA,
STANDARD TANDEM FLAT BED 80K GROSS
12K FORKLIFT UNLOAD
8' ROLLER BED
2 SUPPORTS,
4,000 LBS TOTAL
HATCH INDICATES
8'-0"-10'-0" WIDE FORKLIFT PATH
AND 4'-0" WALK PATH
TRUCK LOAD/ UNLOAD AREA,
STANDARD TANDEM VAN
80K GROSS, MULTIPLE
GAS STORAGE CABINET* GAS STORAGE CABINET* WELD BOTTLE
STORAGE*
FINISHED
PRODUCT
READY TO
PALLETIZE
ASSEMBLY AREA
IF REQUIRED
SAND BLAST
AREA
MAKE-UP AIR UNIT
SIZE T.B.D.
10'-9 3/4" 3'-4 1/2" 10'-9 3/4"
BRIDGE CRANE
5 TON
22'-0" HOOK HEIGHT
ALT: 10 TON. 26'-0" HOOK HEIGHT
BRIDGE CRANE
5 TON
16'-0" HOOK HEIGHT
ALT: 10 TON, 20'-0" HOOK HEIGHT
13'-0"37'-0"
10'-0"
117G
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:49 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:49 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
A-101.2
1" = 10'-0"
Main Level Manufacturing
KMS
KMS
KMS
26PROEM
Issue Date
1" = 10'-0"1 manufacturing Callout 2
N
No. Description Date
36
1
2
E FE.9
261.84 ft²
OFFICE
119
49.27 ft²
7'-6 13/16" X 6'-6 1/8"
UNISEX
121
6X6
A
6'WORKSTATION
6'WORKSTATION
1
S-104
13'-0"X16'-7"
6X6
289.5 ft²
20'-3 7/16" X 14'-3 1/4"
COMPRESSOR
ROOM
123
173.19 ft²
21'-11 1/4" X 7'-10 3/4"
MECH. /
JANITOR
115
TYPICAL SIZE OF
FLOOR SWEEPER
TOOL/ PARTS STORAGE ON WALL
119A121
117G
115B
115A
36 36
36
36
LD
D
C
A
L
L
J.1
25'-9"
8'-6" 6'-11 1/2" 6'-6"
8'-10"
23'-0"
8'-6" 13'-5 1/2"
J.1
123
1
E FD.9 E.9
NITROGEN
1,500 GALLON TANK
80"
ARGON
3,000 L
TANK
58"
15'-6"
21'-0"
8'-11" 289.5 ft²
20'-3 7/16" X 14'-3 1/4"
COMPRESSOR
ROOM
123
50HP SCREW
COMPRESSOR
50HP SCREW
COMPRESSOR
123
LIQUID
OXYGEN
3,000 L
TANK
58"
20' MIN.
23'-0"
3,000L GALLON
LIQUID OXYGEN REQUIRES 20'
FROM OTHER FUEL SOURCES
(ARGON AND NITROGEN ARE INERT
AND NOT CONSIDERED FUEL)
ALUMINUM SCRAP IS
NOT CONSIDERED A FUEL
AS IT ABSORBS HEAT
AND MELTS INSTEAD OF
BURNING
40'-0"10'-0"
15'-0" 14'-6" 0"
30" DROP MAX
GUARD RAIL REQUIRED IF WALKING
SURFACE IS MORE THAN 30" ABOVE GRADE
30" DROP MAX
13'-0" 37'-0"
SKID BASED-
BULK VESSEL,
15K POUNDS EA
MIXER
12' WALLS
J
J
J
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:49 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:49 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
A-101.3
As indicated
Main Level Manuf. callout
KMS
KMS
KMS
26PROEM
Issue Date
1/4" = 1'-0"1 manufacturing Office
1 : 603 manufacturing Callout mechanical apron
No. Description Date
37
01-Level 1
100'-0"
02-Low Eave Office
114'-2"
T.O. Dock Footing
92'-0"
T.O. Footing
96'-0"
04-Roof
126'-0"
03- Parapet Office
117'-0"
6
26 GA. METAL STANDING SEAM ROOFING PANELS
26 GA. METAL VEE RIB
WALL PANELS
26 GA. TEXTURE CLAD WALL PANELS
26 GA. TEXTURE CLAD WALL PANELS PAINTED
26 GA. METAL VEE RIB WALL
PANELS FOR SCREENED AREA
26 GA. METAL VEE RIB WALL PANELS
26 GA. TEXTURE CLAD
WALL PANELS
TRIMS BY BUILDING
MANUFACTURER
STRUCTURAL COLUMNS WRAPPED IN
METAL STUDS AND THEN FALSE STONE
TPO ROOFING
26 GA. METAL VEE RIB WALL PANELS
ALTERNATE: 10 TON BRIDGE CRANES. REQUIRING AN ADDITIONAL
4'-0" FEET IN ELEVATION, CHANGING THE ROOF LEVEL TO 130'-0"
01-Level 1
100'-0"
02-Low Eave Office
114'-2"
T.O. Dock Footing
92'-0"
T.O. Footing
96'-0"
04-Roof
126'-0"
1/4" / 12"
1" / 12"
03- Parapet Office
117'-0"
WALL SIGN SHALL NOT EXCEED 10 PERCENT OF WALL AREA
WALL IS 1,275 SQFT @10% SIGN NOT TO EXCEED 127.5 SQFT
26 GA. METAL STANDING SEAM ROOFING PANELS
26 GA. METAL VEE RIB WALL PANELS
26 GA. TEXTURE CLAD WALL PANELS
26 GA. TEXTURE CLAD WALL PANELS PAINTED
STRUCTURAL COLUMNS WRAPPED IN
METAL STUDS AND THEN FALSE STONE
26 GA. METAL VEE RIB WALL PANELS FOR SCREENED AREA
26 GA. METAL VEE RIB WALL PANELS
26 GA. TEXTURE CLAD
WALL PANELS
TRIMS BY BUILDING
MANUFACTURER
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:50 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:50 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
A-201
As indicated
Elevations
KMS
KMS
KMS
26PROEM
Issue Date
1/8" = 1'-0"1 Right
1" = 10'-0"2 Front
No. Description Date
38
01-Level 1
100'-0"
T.O. Footing
96'-0"
04-Roof
126'-0"
1" / 12"
03- Parapet Office
117'-0"
6" 6'-11 3/4"
6" 5'-6"
26 GA. METAL STANDING SEAM ROOFING PANELS
26 GA. METAL VEE RIB WALL PANELS
26 GA. TEXTURE CLAD WALL PANELS
26 GA. TEXTURE CLAD WALL PANELS PAINTED
STRUCTURAL COLUMNS WRAPPED IN
METAL STUDS AND THEN FALSE STONE
26 GA. METAL VEE RIB WALL PANELS
26 GA. TEXTURE CLAD
WALL PANELS
TRIMS BY BUILDING
MANUFACTURER
APPROX. AIR GAP
APPROX. PANEL SIZE
APPROX. AIR GAP
APPROX. PANEL SIZE
ALTERNATE: 10 TON BRIDGE CRANES. REQUIRING AN ADDITIONAL
4'-0" FEET IN ELEVATION, CHANGING THE ROOF LEVEL TO 130'-0"
01-Level 1
100'-0"
T.O. Dock Footing
92'-0"
T.O. Footing
96'-0"
APPROX
38'-8 7/8"
26 GA. METAL STANDING SEAM ROOFING PANELS
26 GA. METAL VEE RIB WALL PANELS
26 GA. METAL VEE RIB WALL PANELS FOR SCREENED AREA
TRIMS BY BUILDING
MANUFACTURER
26 GA. METAL VEE RIB WALL PANELS
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:50 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:50 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
A-202
As indicated
Elevations
KMS
KMS
KMS
26PROEM
Issue Date
1/8" = 1'-0"1 Left
1" = 10'-0"2 Rear
No. Description Date
39
01-Level 1
100'-0"
02-Low Eave Office
114'-2"
T.O. Footing
96'-0"
04-Roof
126'-0"
1/4" / 12"
03- Parapet Office
117'-0"
03- Parapet Office
117'-0"
APPROX. STEP
11'-1 7/8"
4" CONCRETE FLOOR
W/ W.W.M OVER VAPOR BARRIER
THIS FOUNDATION FOOTING OFF SET
FOR FUTURE EXPANSION FOUNDATION
FOUNDATION WALL
2" RIGID INSULATION
14'-2"
17'-0"
75'-0"
APPROX. FRAME LINE
R-35 INSULATION OVER
METAL "B" DECKING
TPO ROOFING
PURLINS SPACING PER MANUFACTURER
APPROX. STEP
11'-1 15/16"
APPROX. ACCESS LADDER
14'-10 1/16"
TYPICAL WALL HEIGHT
10'-1 1/8"
DROPPED CEILING TYPICAL HEIGHT
9'-8"
EXTERIOR METAL GIRTS
W/ R-30 INSULATION
EXTERIOR METAL SIDING PANELS
VARIES BY MANUFACTURER
SIMPLE SAVER
METAL BUILDING COLUMN
3 5/8" METAL STUD WALL
5/8" GYPSUM FINISH
4'-8 7/16"6"
4'-3"6"
APPROX. AIR GAP
APPROX. PANEL SIZE
ALTERNATE: 10 TON BRIDGE CRANES. REQUIRING AN ADDITIONAL
4'-0" FEET IN ELEVATION, CHANGING THE ROOF LEVEL TO 130'-0"
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:50 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:50 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
A-301
1/4" = 1'-0"
Sections
KMS
KMS
KMS
26PROEM
Issue Date
1/4" = 1'-0"1 Section 2
No. Description Date
40
A-202
A-2022 Rear
A-201 2 Front
1 Left
1
2
3
4
5
6
7
8
9
A B C D E F J
1" / 12"
1" / 12"
125'-0" 75'-0"
42'-0"
26'-0" LOW EAVE
38'-6" HIGH EAVE
42'-0" 150'-0"
C.4 HGD.9 E.9 F.7
14'-2" LOW EAVE
17'-0" TOP OF PARAPET
STANDING SEAM GALVALUME ROOFING
5'-0" 192'-0"
GUTTER
7.3
G.9
1/4" / 12"
GUTTER
TPO ROOFING
14'-0"
3/4" / 12"
200'-0"
150'-0"
200'-0"
ROOFTOP UNIT
48FEEM16A2A6-0A0A0
WEIGHT W/ CURB 2,015#
ROOFTOP UNIT
48FEEM16A2A6-0A0A0
WEIGHT W/ CURB 2,015#
ROOFTOP UNIT
48FEEM16A2A6-0A0A0
WEIGHT W/ CURB 2,015#
ROOFTOP UNIT
48FEEM16A2A6-0A0A0
WEIGHT W/ CURB 2,015#
SCREENING AS REQUIRED PER 18.10.060
TYPICAL FOR ANY ROOF MOUNT ITEM
17'-0" TOP OF PARAPET
ROOFTOP UNIT
48FEEM08A2A6-0A0A0
WEIGHT W/ CURB 802#
LADDER ACCESS
TO OFFICE ROOF
CAGED LADDER ACCESS
TO MANUFACTURING ROOF
APPROX. 32'-6" OVER 24'
LSS OR PFAS SYSTEM REQUIRED
2'-0"
15'-6"
21'-0"
5'-0"
5'-0"
5'-0"
2" / 12"
GUTTER
17'-8 9/16"
19'-9 3/4"
12'-8 7/8"
20'-8 1/2"
ALTERNATE: 30'-0" LOW EAVE
ALTERNATE: 42'-6" HIGH EAVE
THIS DRAWING IS THE PROPERTY OF DURAND
BUILDERS SERVICE, INC. REPRODUCTION OF THIS
DRAWING IN ANY FORM VIOLATES COPYRIGHT LAW
PO BOX 10
DURAND, WISCONSIN 54736
DURAND OFFICE
MAIN NUMBER: (715) 672-5941
FAX NUMBER: (715) 672-8886
WWW.DURANDBUILDERS.COM
COPYRIGHT:WWW.HomeTownBC.com
DESIGNED BY:
DRAWN BY:
CHECKED BY:
Project Number:
7/21/2026 11:41:53 AM P:\project spectacle\design\revit\project spectacle 3.rvt
7/21/2026 11:41:53 AM
NEW BUILDING
Project Spectacle
GATEWAY PARK
07/21/26
S-105
1/16" = 1'-0"
Roof Plan
KMS
KMS
KMS
26PROEM
Issue Date
1/16" = 1'-0"1 03-Roof
No. Description Date
41
1
GENERAL DEVELOPMENT PLAN
GATEWAY NORTHWEST BUSINESS PARK – PHASE II
Amended February 12, 2019
General Purpose
The purpose of this General Development Plan is to provide for development of a moderate
amenity business park allowing such uses as warehousing, distribution centers, industrial sales
or service, light manufacturing and production, and related compatible uses. These provisions
are intended for the protection from incompatible, unsightly, or nuisance uses, which will serve
to maintain property values and attract firms consistent with the Gateway Northwest Business
Park Plan – Phase II. The provisions of this plan are as provided in Chapter 18.10 of the City’s
Zoning Code. The administration of these provisions is further stated in said chapter.
I. Development Review Process
The review process for development within this business park is established in Section
18.10.030 of the Zoning Ordinance.
A. General Development Plan – This General Development Plan provides the
restrictions for the development of this property as required by the provisions of
Section 18.10.030 of the Zoning Ordinance.
B. Final Implementation Plan – Prior to development of any property within this
area, a site plan as required by Section 18.10.030 of the Zoning Ordinance must
be submitted for Plan Commission consideration. Such site plan must be in
compliance with these provisions.
II. Permitted Uses
Those uses permitted in the Gateway Northwest Business Park are the following as
defined in Section 18.06.040 of the City Zoning Ordinance:
A. Warehouse and Distribution
B. Industrial Services
C. Industrial Products Sales
D. Light Manufacturing and Production\
III. Conditional Uses
The following conditional uses are permitted in the Gateway Northwest Business Park,
only upon the granting of a conditional use permit by the City Plan Commission in
accordance with Chapter 18.35 of the City Zoning Ordinance, or as amended.
A. Public and quasi-public uses such as utilities, transportation or communication.
B. Office activities as defined in Section 18.05.040 B. (It is the intent of this
provision to allow certain office activities associated to or compatible with the
42
2
permitted uses listed herein. Such activities may include contractor’s offices,
research and development facilities, testing laboratories and other similar
facilities. This should not include professional facilities.)
C. Restaurants.
D. Vehicle Services.
E. Any use involving an outdoor storage yard for materials used in production or
equipment that is over 200 square feet in size.
IV. Yard Setbacks
Minimum setback from County Highway T is 50 feet. Minimum side yard shall be 10
feet, minimum rear yard shall be 20 feet, and a minimum front yard shall be 25 feet.
Structures such as fences may be allowed in side or rear yards; however, shall be
prohibited in the front yard. Signs shall be permitted in the required front yard as
provided herein.
V. Building Design
Exterior walls of buildings may be of steel, masonry, wood or similar building materials.
Rooftop equipment should be screened from view from the front yard street.
Quality design is encouraged. Bright, primary colors should be avoided unless they are
an integral part of the architectural design, or can be justified on the basis of a
company’s image or logo.
VI. Non-building Site Elements
All operations shall be carried on within fully enclosed buildings and no outside activities
shall be carried on except storage of materials used in, or resulting from, an on-site
manufacturing operation, the parking of motor vehicles and the loading or unloading of
motor vehicles.
Materials, supplies, or products stored outside are to be surrounded by a masonry wall,
opaque fence or suitable screen approved as part of the site plan.
All walks, parking areas, driveways, and loading zones shall be paved and storage yards
may be constructed of a dust-free, all-weather surface which would prevent dust and
erosion.
VII. Access
Access from County Line Road or local streets shall be approved as part of the site plan
review.
VIII. Parking
Parking may be permitted in front or side yards, facing streets, not closer than 10 feet
from the street right-of-way. The number, size, dimensions and layout of parking spaces
shall be as provided in Chapter 18.25 of the Zoning Ordinance.
43
3
The width and location of all driveways/curb cuts shall be as approved by the site plan
consistent with Section 18.10.060 E. of the Zoning Ordinance.
IX. Landscaping and Open Space
Landscaping consisting of lawn, trees, shrubs, flowers, etc., shall be completed by the
owners and tenants at the time of occupancy, or commencing at the next growing
season.
At least 10 percent of all parcels shall be set aside, maintained as landscaped open
space areas, and located where visible from the adjacent public street(s). In general,
front yard areas should be landscaped other than driveways and parking. A minimum of
10 feet between public right-of-way and paved areas shall be landscaped.
X. Screening of External Activities
All exterior activities shall be screened as provided in Section 18.10.060 H. of the Zoning
Ordinance.
All parcels abutting exterior lot lines of this business park shall be provided with solid
effective screening as provided in Section 18.20.170 of the Zoning Ordinance to protect
any planned or existing non-business use. Such screening shall be indicated on the
approved site plan.
XI. Fences
Fences are permitted, provided that no fence shall extend into the 25-foot setback from
the street (or, in the case of N. Clairemont Avenue/Highway T, the 50-foot setback from
the street). Any fencing protruding beyond the building line facing the street shall provide
for landscaping to soften the appearance of the fencing. Unless an opaque or solid
screen is otherwise required to shield materials stored outside, coated wire mesh
fencing is preferred. No fencing shall exceed six feet in height unless otherwise
permitted by the site plan. Fences must be kept in good repair and wood fences should
be kept stained or painted. Provisions must be made for access by Fire Department
apparatus to all sides of any building.
XII. Signs
One freestanding, monument type sign per principal building shall be allowed. The total
size of the freestanding sign shall not exceed 70 square feet. Maximum height of all
monument signs permitted shall not exceed 6 feet above ground level. These signs
must be set back a minimum of 15 feet from street rights-of-way. For principal buildings
that have more than one business tenant, the maximum size shall not exceed 150
square feet. Maximum height shall not exceed 15 feet. These signs must be setback a
minimum of 15 feet from street right-of-way and are subject to the approval of a sign
plan in 16.16.070 A5.
Wall signs shall not exceed 10 percent of the wall area in which the sign is placed or 250
square feet (whichever is less).
44
4
Identification signs with a maximum 60 square feet in area shall be permitted at major
entrances to the park.
Except as provided above, the sign provisions of the Eau Claire Zoning Ordinance (Title
18) and Sign Code (Chapter 16.16) shall apply to all signs used in the Gateway
Northwest Business Park – Phase II.
XIII. Utilities
All electric and telephone utilities must be placed underground.
XIV. Lighting
Lighting shall be in accordance with Section 18.10.060 F. of the Zoning Ordinance.
XV. Drainage Systems
No one shall in any way disturb the functioning of the man-made or natural drainage
system of Gateway Northwest Business Park in any manner, except with the express,
written permission of the City Engineer.
All portions of any lot shall be designed, graded, constructed and maintained so as to
properly discharge storm water runoff, as set forth on the approved site plan.
XVI. Maintenance of Vacant Land
All vacant lots or land shall be maintained by the property owner in terms of weeds, trash
and other materials as required by city code.
XVII. Private Wells
Wells for outside watering and industrial use may be approved within the standards
developed by the State of Wisconsin and the City of Eau Claire.
XVIII. Industrial Waste into Sanitary Sewers
Industrial pretreatment of effluents from their source will be required, in accordance with
uses and standards established by the City of Eau Claire, in conformance with the Clean
Water Act and regulations of the Wisconsin Department of Natural Resources and the
Environmental Protection Agency.
No industrial process shall be permitted that would discharge industrial wastes into the
City’s sewage treatment system at a rate or a composition beyond the capacity of the
system to treat it satisfactorily.
XIX. Start of Construction
The owner shall, within 12 months of the date of lot(s) purchase, commence construction
and shall have the same ready for occupancy for an allowed use within 24 months of the
date of said lot(s) purchase, unless a formal extension is requested of and granted by
the Gateway West Business Park Corporation. If there is no extension granted or no
45
5
construction commences, Gateway reserves the right to repurchase the land at its
original cost, plus the cost of any subsequent improvements.
XX. Amendment and Ownership
Each lot shall be conveyed subject to the above standards, all of which are to run with
the land and shall be binding on all parties and all persons claiming them. Amendment
of these standards is provided in Section 18.10.040 C. of the City Zoning Code upon
approval by the City Council after review by the City Plan Commission.
46
203 S. Farwell St., P.O. Box 5148, Eau Claire, WI 54702-5148 - www.eauclairewi.gov
COMMUNITY DEVELOPMENT
Economic Development: (715) 839-4914
Inspections: (715) 839-4947
Planning: (715) 839-4914
Fax: (715) 839-4939
City of Eau Claire
2027 Meeting Dates and Deadlines
Applications must be submitted by Noon
Application Deadlines for
All Applications:
Rezoning, Conditional Use, P-Public, Site Plan, Plat,
Developer’s Agreement, Comprehensive Plan
Amendments, & Other Applications
For the
Plan Commission
meeting of:
For the
City Council
meeting of:
November 24 January 4 January 11 & 12
January 25 & 26
December 22 February 1 February 8 & 9
February 22 & 23
January 19 March 1 March 8 & 9
March 22 & 23
February 23 April 5 April 12 & 13
April 26 & 27
March 23 May 3 May 10 & 11
May 24 & 25
April 21 June 1 (Tuesday) June 7 & 8
June 21 & 22
May 26 July 6 (Tuesday) July 12 & 13
July 26 & 27
June 21 August 2 August 9 & 10
August 23 & 24
July 28 September 7 (Tuesday) September 13 & 14
September 27 & 28
August 24 October 4 October 11 & 12
October 25 & 26
September 21 November 1 November 8 & 9
November 22 & 23
October 26 December 6 December 13 & 14
December 27* & 28*
PC-Plan Commission / CC-City Council * Subject to change
• All completed applications must be submitted by noon on the due date at the following site:
https://evolvepublic.infovisionsoftware.com/eauclaire/?portal=project
• Specific application instructions, checklists, and resources (Land Development Ordinance (LDO) Applications &
Manual) can be found at https://www.eauclairewi.gov/629/Applications---Planning-Division
• City staff has up to 10 (ten) business days to determine if applications are complete. Once considered complete, the
official review period will begin. Following the LDO manual will help ensure your application is complete.
• Some applications require both Plan Commission and City Council approval.
• Council Mondays are public hearings and Tuesday meetings are when they take action.
• Depending on the location or scope of project, some applications may require additional review from other City
boards prior to Plan Commission review (e.g., Waterways, Parks & Urban Forestry Commission, Landmarks
Commission, etc.).
• For questions, please contact the Planning Division staff at 715-839-4914 or planning@eauclairewi.gov
DRAFT
47