CITY OF PRESCOTT, WISCONSIN
MEETING NOTICE
PLANNING COMMISSION
MONDAY, JULY 8, 2026
6:00 P.M.
PRESCOTT CITY HALL
800 BORNER ST., PRESCOTT, WI 54021
1) Call to Order
2) Roll Call
3) Approve Plan Commission Minutes – June 1, 2026
4) Public hearing – Conditional Use Permit for Assisted Living Facility at 445
Court Street
a) Hold Public Hearing Regarding Resolution XX-26 Approving CUP for an
Assisted Living Facility at 445 Court Street.
b) Consideration and possible action of “A Resolution Approving A
Conditional Use Permit for an Assisted Living Facility at 445 Court Street.
c) Consideration and possible action of “A Resolution Approving The Site
Plan Review For The Assisted-Living Development At 445 Court Street”
5) Certified Survey Map Adjusting Lot Dimensions for Lots 1, 501 Sunset Court,
and 2, 1201 Pearl St. In SW 1/4 of the SW 1/4 of Section 3, Township 26N,
Range 20W
6) Review and Consideration of Approval to Hold a Public Hearing Regarding
Zoning Code Changes for Conditional Uses at the August 3, 2026 Meeting
7) Other Business
a) Next Meeting – Monday, August 3 at 6:00 PM
8) Adjourn
ACCESS TO THE MUNICIPAL BUILDING FOR THE DISABLED IS AVAILABLE THROUGH
THE REAR PARKING LOT ENTRANCE. ALL THOSE WITH SPECIAL NEEDS SHOULD
CALL CITY HALL OFFICES (262-5544) IF ASSISTANCE IS REQUIRED.
Planning Commission Meeting Minutes
June 1st, 2026
Pursuant to due call and notice thereof, a meeting of the Planning Commission was held on
June 1st, 2026, at the Municipal Building, 800 Borner Street, Prescott, Wisconsin 54021. The
meeting was called to order at 6:00 PM
Commission Present: Mayor Mike Gerke, Joel Reice, Steve Most, Bailey Ruona, Josh
Gergen, Dave Hovel, Kate Otto
Commission Absent: Steve Most
Staff Present: City Administrator Matt Wolf, City Planner Luke Wiese
Others Present: Greg Adams from Cedar Corporation, Ken Jaworski from Cedar
Corporation (attended virtually), members of the public
1. Approve minutes for May 4th, 2026
Commissioner Gergen motioned to approve the minutes, Ruona seconded; motion
passed without a negative voice vote (6-0)
2. Public hearing on the proposed City of Prescott Comprehensive Plan 2026–
2046.
Ken Jaworski of Cedar Corporation presented the proposed 2026–2046 Comprehensive
Plan. Jaworski discussed the purpose of the Comprehensive Plan update and summarized
the community survey results, including what residents value about Prescott and perceived
strengths and weaknesses within the community. He also reviewed several maps included
in the plan, including the planned bikeways and pedestrian facilities map and the Future
Land Use Map. Jaworski noted that the Future Land Use Map identifies potential growth
areas and anticipated land uses, but that it is intended to be a guide and may be amended
over time as conditions change.
Commissioner Hovel motioned to open the public hearing, Ruona seconded, motion
passed without a negative (6-0).
There were no comments.
Commissioner Hovel motioned to close the public hearing, Ruona seconded; motion
passed without a negative voice (6-0).
Commissioner Hovel motioned to approve Resolution 02-26 A Resolution of the Plan
Commission Recommending Adoption of The “City of Prescott Comprehensive Plan
2026 – 2046” Update. Ruona seconded; motion passed without a negative voice (6-0).
3. Conditional Use Review
City Planner Wiese presented a review of the City's conditional uses. Wiese explained that
under Wisconsin law, if a use is listed as a conditional use within a zoning district, it is
generally presumed to be appropriate for that district, with review focused on conditions
rather than whether the use itself is allowed. Because of this, the Plan Commission
reviewed conditional uses that may no longer fit the intent of their respective zoning
districts.
The Plan Commission received a review matrix of conditional uses in the City. The four
conditional uses identified for discussion were:
• Allowing ADUs in the R-5 Single-Family Residential District
• Airports, airstrips, and landing fields in the I-2 Heavy Industrial District
• Railroads and railroad facilities in the I-2 Heavy Industrial District
• Large-scale solar facilities in the C-1, I-1, I-2, and I-3 Districts
The Plan Commission discussed the relevance of each use within its corresponding
district. Although development of large-scale solar facilities is unlikely, the Plan
Commission expressed concern that portions of the City's commercial and industrial areas
could be used for solar generation rather than the intended uses of those districts. The Plan
Commission directed staff to prepare ordinance amendments removing large-scale solar
facilities as a conditional use in all districts. Similar direction was provided for airports,
airstrips, landing fields, railroads, and railroad facilities in the I-2 District.
When discussing ADUs, the Plan Commission felt the use was appropriate with the R-5
District and directed staff to prepare an ordinance amendment allowing ADUs as a
conditional use in R-5.
Hovel motioned to direct staff to draft a new ordinance allowing ADU’s in R-5 single
family residential and remove the other conditional uses from those chapters. Ruona
seconded; motion passed without a negative voice (6-0).
4. Other Business
City Administrator Wolf provided an update on the proposed Assisted Living Facility at 445
Court Street. The developer has submitted portions of the final site plans, and the City is
awaiting the complete application before placing the item on a future Plan Commission
agenda.
The Plan Commission also discussed next month's meeting scheduled for Monday, July 6.
Because the meeting falls close to the holiday weekend, some members may be
unavailable. The Plan Commission will tentatively reschedule or cancel the meeting
depending on the items requiring consideration.
Commissioner Hovel motioned to adjourn. Ruona seconded; motion passed without a
negative voice vote (6-0). The meeting was adjourned at 6:28 PM.
The next Plan Commission meeting will be held on Monday, July 6th, 2026, at 6:00 PM at
Prescott City Hall.
Respectfully Submitted,
Luke Wiese
Planner
To: Plan Commission
From: Luke Wiese, Planner
Date: July 1st, 2026
Subject: 445 Court Street Assisted Living Site Plan Review
Background
Nottingham Construction has submitted a conditional use permit application and site plan for a
new assisted living facility at 445 Court Street North. The property previously operated as a
hospital and daycare before the long vacant facility was demolished in 2023. The parcel has
remained vacant since then. 445 Court
Street has seen several iterations of
residential development proposals over the
years. Earlier concepts included senior
housing and later duplexes. Nottingham
Construction is now proposing an assisted-
living facility.
On August 4, 2025, the Plan Commission
reviewed and forwarded the Concept Plan
for 445 Court St to Council for approval on
August 11, 2025. Since that review, the
developer has added parking, revised the
layout, and included additional stormwater
drainage and accessibility features.
In total, the revised plan consists of 59
total units with 67 total bedrooms:
• Studio: 17
• 1-Bed: 34
• 2-Bed: 8
As per Prescott Zoning Code § 635-120, site plan applications are subject to the review of the
Plan Commission and final action of the council. As per Prescott Zoning Code § 635-17
Community-based residential facilities or assisted living facilities are allowed as a conditional
use.
Discussion
Surrounding Land Use
The proposed development is approximately 2.24 acres (PID 271010636100) and is located in
the R-1 Mixed Density Residential District. It has single family residential on three sides and the
higher density Peacock Ridge estates on its West.
Direction Existing Use Zoning
North Single-Family Residential R-1 Mixed Residential
East Single-Family Residential R-1 Mixed Residential
South Single-Family Residential R-1 Mixed Residential
West Peacock Ridge Estates R-1 Mixed Residential
(Planned Unit Development
Overlay)
Zoning and Setbacks
The property is zoned R-1 – Mixed Density Residential. The Mixed Residential District is
intended to provide a quiet, pleasant living area protected from traffic, congestion and
incompatible land uses. This District is designed to maintain compact residential development
near existing residential areas and presently served or readily serviceable by public sewer and
water.
Per City Code § 635-17 (R-1 Mixed Residential District), a community based residential facility
or assisted living facility is an approved Conditional Use
Because the proposed use is listed as a conditional use in the R-1 District, the review should
focus on whether the application satisfies the City’s applicable conditional use standards and
whether any conditions of approval are related to those standards. Consistent with Wisconsin
Act 67, any conditions imposed should be reasonable, measurable, and supported by
substantial evidence in the record.
Based on the submitted site plan, the proposed use is located on a previously developed
institutional site, meets the applicable dimensional standards, provides off-street parking above
the minimum requirement, and includes stormwater, landscaping, and site access
improvements. Conditions of approval may be included in the resolutions to address final
engineering review, stormwater verification, erosion control, utilities, lighting, landscaping,
refuse/storage, and compliance with applicable building, fire, state licensing, and zoning
requirements.
Below is a table for the setbacks:
Standard Required (R-1) Proposed Notes
Front/Street-Side
Setback (Corner Lot)
25 ft 25 ft Compliant
Side Setback (Non-
Street-Side Property
Lines)
12 ft 25 ft Compliant
Maximum Building
Height
35 ft 34 ft Compliant
Maximum Lot
Coverage
(Structures)
50% 25.8% Compliant
Maximum Lot
Coverage (Total
Impervious Surface)
70% 67.1% Compliant
Site access is proposed from Oak Street and Court Street. Oak Street would have two access
points: the southwestern access would serve the underground parking area, and the second
Oak Street access would connect to the surface parking lot. The Court Street access would also
connect to the surface parking lot.
Parking and Loading (635-55)
Under § 635-55 Parking Requirements, one parking stall is required for each bedroom. The
proposal includes 67 bedrooms, requiring a minimum of 67 stalls. The submitted site plan
provides 80 stalls in total, including 18 underground stalls and 7 ADA-compliant stalls. This
exceeds the minimum requirement. When the concept plan was initially shown to Plan
Commission in August of 2025, the facility included 40 parking stalls. To accommodate Plan
Commission feedback, the developer has submitted this new plan to meet the standard.
Standard Required Proposed Compliant?
Regular Stalls 67 73 Yes
ADA Stalls 3 7 Yes
Loading, service, and refuse access is adequate based on the submitted plan. Refuse
containers and related storage are proposed to be kept within the underground parking area.
Architectural Standards (635-80)
City Code § 635-80 requires new multi-family development to meet minimum architectural
design standards and conform to surrounding development patterns. Based on the submitted
elevations and renderings, the proposal provides compatible colors, materials, and façade
articulation. Primary exterior materials include blue LP SmartSide lap siding, composite shake
siding and stone veneer.
Landscape Standards (635-107)
Per § 635-107, residential development is subject to the L-2 Landscape Standard. L-2 requires
one tree for every 30 feet of lot frontage and six shrubs for every 30 feet of frontage.
Item Standard (L-
2)
Project
Frontage/Calc
Required Proposed
Trees along
frontage
1 per 30 LF 662 LF ÷ 30 22 36
Shrubs along
frontage
6 per 30 LF 662 LF ÷ 30 × 6 132 182
Exterior Lighting (635-75)
Currently, the site plan does not include an exterior lighting plan. Exterior lighting within the City
is regulated under § 635-75 to prevent glare and light trespass onto adjacent properties. No light
source may be directly visible beyond the boundaries of the zoning district, and lighting may not
produce intense glare or exceed allowable illumination levels at property lines.
If exterior lighting is installed as part of this development, it must comply with § 635-75.
Stormwater Management and Erosion Control
The City Engineer reviewed the civil construction plans, erosion control plan, and stormwater
management plan. The project will disturb approximately 2.25 acres and will require a WDNR
Notice of Intent (NOI) under NR 216 and NR 151.
Stormwater will be managed through a proposed underground ADS StormTech detention and
treatment system located beneath the east parking lot. The system includes three chamber
rows that are approximately 8.3 feet wide, 124 feet long, and 5 feet tall. The system is intended
to reduce post-development runoff rates and provide total suspended solids (TSS) removal
before runoff is discharged to the existing storm sewer system.
The east side of the building roof and the east parking lot drain to the underground system. The
reduced discharge from the underground system is piped to the existing storm manhole on the
west side of the property, which connects to the City storm sewer system.
The City Engineer noted that the post-development runoff model appears to show the west side
of the building roof draining to the underground system, while the plans show that area
connecting to the storm sewer system on the west side of the site. The engineer must verify the
correct modeling of the west side of the building roof. This verification will be included as a
condition of approval.
The submitted stormwater modeling shows that post-development runoff rates are lower than
pre-development rates for the modeled storm events. These rates remain subject to the
verification noted above.
Table 1 below represents the pre-development and post-development runoff draining to the
existing storm manhole and 12-inch storm sewer on the west side of the site toward the
Peacock Ridge development.
Table 1: Rate Attenuation Summary – To Lone Storm Structure on Site
1.5” Event (1.5
in.)
2 Year (2.84 in.) 10 Year (4.20
in.)
100 year (7.29
in)
Pre-
Development
Rate (CFS)
0.35 1.78 3.60 8.33
Post-
Development
Rate
0.32 0.60 2.50 6.61
Percent
Reduction
-8.5% -66.3% -30.5% -20.6%
Table 2 below represents the pre-development and post-development runoff draining overland
offsite to the west property line toward Peacock Ridge. The post-development rates for the
modeled storm events are less than the existing pre-development rates. These rates remain
subject to the roof-drainage modeling verification noted above.
Table 2: Rate Attenuation Summary – Offsite to Peacock Ridge
1.5” Event (1.5
in.)
2 Year (2.84 in.) 10 Year (4.20
in.)
100 Year (7.29
in.)
Pre-
Development
Rate (CFS)
0.01 0.30 0.81 2.3
Post-
Development
Rate (CFS)
0.00 0.08 0.37 1.38
Percent
reduction
-100% -73.3% -54.3% -40.0%
The City and WDNR require redevelopment sites to meet 40% total suspended solids (TSS)
removal. The stormwater quality modeling shows a TSS removal rate of 43.6%.
Utilities:
The water and sewer connect on the west side of the property on Oak Street. The property
previously had 2-inch water and sewer connections. The proposed development incorporates 6-
inch connections. As part of the site plan approval resolution, the City will charge the applicable
water and sewer connection/impact fees based on the proposed 6-inch connections, with credit
given for the existing 2-inch connections. After applying that credit, the estimated fees are
$86,443 for sewer and $28,123 for water.
Water:
Sewer:
445 Court
St. - Total
Proposed
Units
Total
Current
Apartment
Units in
Prescott
Total Avg.
Daily
Sewage
Usage Per
Apt. Unit
(gal.)
Total Avg.
Daily Sewage
Usage all Apt.
Units (Pre-
Assisted Living
Dev.)
Total
Sewage
Increase
from
Assisted
Living Dev.
(59 Units)
Total Average Daily
Sewer Treatment
Usage (All City)
Pre-Assisted Living
Dev.
Total Average Daily
Sewer Treatment
Usage (All City)
Post-Assisted Living
Dev. (+59 Units)
59 384 77 37,730 4,543 352,162 356,705
*Prescott Sewer Treatment Plant has a Total Capacity of 500,000 Gallons
per Day
Conclusion
Based on the submitted materials, the proposed assisted living facility meets the applicable
dimensional, parking, landscaping, architectural, and impervious surface standards reviewed in
this memo. The remaining technical items, including final stormwater verification, can be
addressed through the conditions included in the resolutions. Staff finds that the proposed use
and site plan meet the applicable requirements of the Zoning Code.
Recommendation
1. Consider approval of resolution XX-26 Approving a Site Plan for an Assisted Living
Development at 445 Court Street.
2. Consider approval of resolution XX-26 Approving a Conditional Use Permit For An
Assisted Living Facility At 445 Court Street.
Attachments
1. Resolution XX-26 445 Court Street Assisted Living Site Plan Review
445 Court St.
- Total
Proposed
Units
Total Current
Apartment
Units in
Prescott
Total Avg.
Daily
Water
Usage Per
Apt. Unit
(gal.)
Total Avg.
Daily Water
Usage all Apt.
Units (Pre-
Assisted-
Living Dev.)
Total Water
Increase
from
Assisted-
Living
Facility (59
Units)
Total Average
Daily Water
Usage (All City)
Pre-Assisted
Living Dev.
Total Average
Daily Water (All
City) Post-
Assisted Living
Dev. (+59 Units)
59 384 77 37,730 4,543 325,847 330,390
*Prescott Wells have a Total Capacity of 3,600,000 Gal. per Day (Assumes a 24 Hour
Run-Time of All 3 Wells)
2. RESOLUTION XX-26 Approving CUP for an Assisted Living Facility at 445 Court St
3. 445 Court Street Site Plan
4. 445 Court Street Elevations and Renderings
5. 445 Court Street Landscape Plan
6. City Engineer Comments
RESOLUTION XX-26
CITY OF PRESCOTT, WISCONSIN
A RESOLUTION APPROVING A CONDITIONAL USE PERMIT FOR AN ASSISTED
LIVING FACILITY AT 445 COURT STREET
WHEREAS, Prescott Properties LLC, a Wisconsin limited liability company (“Owner”)
submitted an application for a Conditional Use Permit to allow the establishment and operation
of an assisted living facility at 445 Court Street, Prescott, Wisconsin; and
WHEREAS, the subject property, hereinafter referred to as the “Property” is legally described as
follows:
LOT 2 of Certified Survey Map recorded in Vol. 5 of C.S.M., Page 54 as Document Number
361800, being a part of Government Lot 3, of Section 9 and part of the Northwest Quarter of the
Southwest Quarter of Section 10, Township 26 North, Range 20 West, including Outlot 1, COPP AND
MAXSON’S ADDITION TO THE CITY OF PRESCOTT and all of FIEDLER’S FIRST ADDITION TO THE CITY OF
PRESCOTT, lying easterly of U.S. Highway “10” and including all that portion of vacated Elm Street lying
northwesterly of Oak Street, all in the City of Prescott, Pierce County ,Wisconsin
WHEREAS, the Property is zoned R-1 Mixed Residential District; and
WHEREAS, assisted living facilities and community-based residential facilities are listed as a
conditional use in the R-1 Mixed Residential District under § 635-17 of the City of Prescott
Municipal Code; and
WHEREAS, the proposed assisted living facility is therefore being reviewed as a conditional use
pursuant to the City’s zoning ordinance and conditional use permit procedures; and
WHEREAS, the Plan Commission reviewed the application, site plan materials, staff report, and
other information submitted in support of the request at its meeting on July 8, 2026; and
WHEREAS, notice of the public hearing was provided in accordance with applicable law and
City ordinance requirements; and
WHEREAS, the Plan Commission found that the proposed conditional use meets the general
standards for conditional uses, including that:
• The establishment, maintenance, or operation of the conditional use will not be
detrimental to or endanger the public health, safety, morals, comfort, or general welfare.
• The use, value, and enjoyment of surrounding properties will not be substantially
impaired and the proposed use is compatible with surrounding land uses.
• The conditional use will not impede the normal and orderly development of surrounding
property.
• Adequate utilities, access roads, drainage, and other site improvements are provided.
• Adequate ingress and egress will minimize traffic congestion on public streets.
• The conditional use conforms to all applicable regulations of the zoning district.
• The proposed use does not violate floodplain regulations governing the site; and
WHEREAS, the Plan Commission recommended approval of the Conditional Use Permit subject
to conditions necessary to ensure compliance with City ordinances and compatibility with
surrounding uses.
NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Prescott,
Wisconsin, as follows:
The City Council hereby approves this Conditional Use Permit allowing the establishment of an
Assisted Living Facility located at the Property, with a current address of 445 Court Street,
Prescott, Wisconsin subject to the conditions outlined below.
Conditions of Approval
• Use Authorized. This Conditional Use Permit authorizes an assisted living facility on the
Property as presently constituted, but not other property, including any additions to the
Property via property consolidation.
• Resident Capacity. The facility shall not exceed 67 bedrooms unless an amendment to the
Conditional Use Permit is reviewed and approved by the City.
• Retaining Wall. The Owner shall retain a City-approved geotechnical engineer or other
qualified licensed professional engineer to inspect and prepare reports regarding the
retaining wall located along the northwest and west property lines. Inspections shall
include one inspection prior to construction, additional inspections during construction if
required by the City, and one inspection following completion of construction. The post-
construction report shall be submitted to and approved by the City prior to issuance of an
occupancy permit. Any damage to, or adverse impact on, the structure or integrity of the
retaining wall resulting from construction activities associated with the development shall
be repaired or corrected by the Owner at the Owner's sole expense.
• Parking and Site Circulation. Required off-street parking for employees, residents,
visitors, service vehicles, and facility operations shall be provided and maintained on the
Property in accordance with the approved site plan and applicable City parking
requirements. Parking areas shall not be reduced, relocated, or altered without City
approval.
• Employee Parking. All employee parking associated with the assisted living facility shall
be accommodated on the Property. Employees shall not utilize on-street parking on
adjacent public streets as their regular place of parking while working at the facility.
• Stormwater, Grading, and Drainage. All stormwater, grading, and drainage improvements
shall be installed in accordance with the plans approved by the City and shall be
maintained in good working order by the property owner/operator. Any modification to
the approved stormwater or drainage system shall require City review and approval.
• Loading, Deliveries, and Service Access. Deliveries, garbage collection, resident
loading/unloading, medical transport, and service vehicles shall be accommodated in a
manner that does not obstruct public streets, sidewalks, drive aisles, required parking
spaces, emergency access areas, or neighboring properties.
• Dumpster and Waste Screening. All outdoor garbage, recycling, waste containers,
dumpsters, and similar refuse areas shall be located as shown on the approved site plan
and screened in accordance with Article XIII of Chapter 635 of the City Code
• Landscaping. Landscaping shall be installed in accordance with the approved landscape
plan and shall be maintained by the property owner/operator.
• Exterior Lighting. Exterior lighting, including building-mounted lighting and parking lot
lighting, shall be installed and maintained in accordance with City Code 635-75.
• State Permits. The assisted living facility shall maintain all licenses and approvals
required by the Wisconsin Department of Health Services. Any increase or substantial
change in the nature of operations shall require review and approval of an amendment to
the Conditional Use Permit.
• Architecture. Exterior elevations shall be consistent with those approved as part of the
Conditional Use Permit application. Any substantial modification to the building’s
architectural appearance, including changes to exterior materials, rooflines, or façade
design, shall be subject to review and approval by the City.
• Emergency Access. Fire lanes and emergency access routes shall be provided and
maintained in accordance with the requirements of the Prescott Fire Department and
applicable provisions of the Wisconsin Commercial Building Code and Fire Code. Such
access areas shall remain unobstructed at all times.
• Fire Suppression System. The facility shall obtain all permits and approvals required by
the Wisconsin Department of Safety and Professional Services and shall install and
maintain all fire suppression, alarm, and life safety systems required by applicable state
codes.
• Emergency Contacts. At least one of the Owner or operator of the assisted living facility
located on the Property shall provide the Prescott Police and Fire Department with
emergency contact information for facility management and shall coordinate emergency
response procedures and building access protocols with the Departments. Updated
contact information shall be provided whenever changes occur.
• Completion of Site Improvements. All required site improvements, including parking,
stormwater, drainage, landscaping, lighting, dumpster screening, retaining wall
improvements, and any other improvements required by the approved plans or City Code,
shall be completed prior to occupancy unless the City approves a financial guarantee or
other arrangement acceptable to the City.
• Compliance with Codes. The Assisted Living Facility shall comply with all applicable
City ordinances, State statutes, and building code requirements.
This Conditional Use Permit shall remain in effect so long as the conditions of approval are
maintained and the use remains in compliance with all applicable City regulations. This
Conditional Use Permit shall be recorded against title to the Property. Approved this 13th day of
July 2026.
______________________________
Michael H. Gerke, Mayor
Attest:
________________________________
Rashel Temmers, City Clerk
ACKNOWLEDGEMENT
STATE OF ____________________ )
)ss.
COUNTY OF __________________ )
Personally came before me on the ____ day of _____________, 202 6, the above -named
___________________________ , to me known to be the person who
executed the foregoing instrument and acknowledged the same.
_______________________________________
___________________________, Notary Public
State of ____________________
My commission expires: ___________________
RESOLUTION XX-26
RESOLUTION APPROVING THE SITE PLAN REVIEW FOR THE ASSISTED-
LIVING DEVELOPMENT AT 445 COURT STREET
WHEREAS Prescott Properties LLC submitted a site plan for an assisted living facility located
at 445 Court St., Parcel ID 271010636100; and
WHEREAS the proposed development consists of an assisted living facility totaling 59 dwelling
units (67 bedrooms) within the R-1 Mixed Residential District; and
WHEREAS, the site plan was reviewed under the City’s applicable site plan review standards,
including the layout of the site, access, parking, loading, drainage, utilities, landscaping, building
appearance, and effect on municipal services; and
WHEREAS the Plan Commission reviewed the site plan at its July 8, 2026, meeting and
forwarded it to the Common Council with a favorable recommendation; and
WHEREAS the Common Council reviewed this item at its regular meeting of July 13th, 2026
and found it to be acceptable.
NOW, THEREFORE, BE IT RESOLVED that the Common Council of the City of Prescott
hereby approves the site plan for the assisted living development at 445 Court Street, Parcel ID
271010636100, subject to the following conditions:
1. The development shall be constructed in substantial conformity with the site plan,
architectural elevations, landscape plan, stormwater management plan, and supporting
documents submitted to the City, except as modified by these conditions.
2. All applicable permits (i.e., building, electrical, mechanical) and a commercial plan review
packet required must be paid, completed, submitted, and approved by the State of
Wisconsin and City of Prescott Building Inspector prior to the commencement of any
construction activities.
3. All applicable water, sewer, connection, impact, and other City fees associated with the
development shall be paid at the time of building permit issuance. The total City impact,
water, and sewer connection fees are as follows:
Table 1: City Impact Fees
Units Police Impact Fee Fire Impact Fee Library Impact Fee Parks Impact Fee Total
Studio Units 17 $2,040 $1,751 $6,494 $8,398 $18,683
1 Bedroom
Units
34 $6,086 $5,236 $19,482 $25,160 $55,964
2 Bedroom
Units
8 $1,896 $1,624 $6,056 $7,816 $17,392
Total 59 $10,022 $8,611 $32,032 $41,374 $92,039
Table 2: Water and Sewer connection impact fees
6” Connection Fee Less 2-inch connection Total
Water $33,480 -$5,357 $28,123
Sewer $103,290 -$16,847 $86,443
Total $136,770 -$22,204 $114,566
4. All disturbed ground surfaces shall be stabilized and restored in accordance with the approved
erosion control plan and applicable City and State requirements.
5. Erosion control must be used to prevent any deterioration of soils or runoff of solids from
draining into public streets and entering the City’s stormwater system. An erosion and
sediment control plan permit must be obtained from the Zoning Administrator, 500-8
6. The site disturbs approximately 2.25 acres and will require a WDNR NOI per NR 216
and NR151.
7. The applicant shall submit final stormwater management plans and calculations for review
and approval by the City Engineer. The final submittal shall verify the correct modeling of
the west side of the building roof drainage and confirm that the proposed s tormwater
system meets applicable rate control and water quality requirements.
8. The City of Prescott shall not own or maintain the private stormwater facilities on the site.
The property owner shall be responsible for the long -term maintenance of all private
stormwater facilities and shall enter into a stormwater maintenance and monit oring
agreement acceptable to the City.
9. The applicant shall install and maintain landscaping in substantial conformity with the
approved landscape plan. Living plant material shall cover at least 70% of the required
landscape area within five years of initial planting.
10. The developer and all future property owners shall maintain the required landscaping and
shall replace dead, diseased, or removed trees and shrubs as necessary to maintain
compliance with the approved landscape plan.
11. Rubbish, garbage, recycling containers, and related storage shall be kept within the
building, underground parking area, or an approved screened enclosure and shall be
maintained so as not to create odor, nuisance, or visual impacts on neighboring properties.
12. All rooftop mechanical equipment shall be screened to be concealed from the public
view.
13. All exterior lighting and parking lot lighting shall comply with applicable City Code
requirements, including §§ 635 -55 and 635 -75. Lighting used to illuminate off -street
parking areas shall be directed away from adjacent properties and public streets and shal l
not exceed three footcandles measured at the lot line.
14. All required resident, visitor, employee, and service parking shall be provided off-street
and maintained available for that purpose.
15. Any substantial modifications to the approved site plan shall require review and approval
by the Plan Commission and City Council.
16. The contractor must coordinate with the City of Prescott for water valve installation, and
coordinate with City staff prior to the work commencing.
Dated this 13th day of July, 2026.
City of Prescott
Michael H. Gerke, Mayor
Attest:
Rashel Temmers, City Clerk
OAK STREET
COURT STREET
66'
MBTP TP TP
FENCEFENCEFENCE
FENCE
GATE
GUARD RAIL
PROPOSED BUILDINGFOOTPRINT± 25,400 SF1ST FLOOR FFE: 778.00BASEMENT FFE: 767.50
T
19.0'19.0'24.0'19.0'10.0'(TYP.)
24.0'
24.0'19.0'24.0'19.0'19.0'24.0'19.0'
24.0'25.0'
25.0'25-FT BUILDINGSETBACK 25-FT BUILDINGSETBACK
25-FT BUILDINGSETBACK
25.0'25-FT BUILDINGSETBACK
P1P2
4-FT PARKINGSETBACK
4-FT PARKINGSETBACK
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
25.0'
6.0'
C1
C1
C1C1
C1 C2C2
C4
C4C4
C4
C4C4
C5C6 P3
P3P3S1S1
R1
R2
22.0'C4C4
4.0'25.0'
R15.0'R15.0'R10.0'18.0'
R1R1
R1
R1
R1R1R3
25.0'
R15.0'R15.0'
P2P2P2
P1
P1P1P1
P1
8.0'8.5'P3
S1S1S1S1S1S1S1S1
C1
R4F1
R15.0'R10.0'R39.0'R30.0'R6.0'R3.0'
C2
24.0'19.0'
R10.0'R15.0'R15.0'
19.0'10.0'(TYP.)6.0'
R5
25-FT BUILDINGSETBACK
R10.0'
R15.0'R15.0'R10.0'
79.0'18.5'61.4'25.5'15.5'
R11ST FLOOR PATIO DOOR -
26.7'
30.5'
26.7'
5.0'10.5'
R6
30.0'15.0'
R5R5R5R5
R5R5R5R5R5
12.7'
R4
R6R6R6R6
R6R6R6
R15.0'R15.0'
This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.SHEET NUMBER
K:\TWC_LDEV\Nottingham Construction\Prescott, WI Assisted Living\3 Design\CAD\PlanSheets\C4-SITE PLAN.dwg May 08, 2026 - 8:26am
BYREVISIONSNo.DATE 2025 KIMLEY-HORN AND ASSOCIATES, INC.767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114PHONE: 651-645-4197WWW.KIMLEY-HORN.COM©PRELIMINARY - NOT FOR CONSTRUCTION
PROPERTY SUMMARYTOTAL PROPERTY AREA2.24 ACDISTURBED AREA2.25 ACEXISTING IMPERVIOUS AREA0.97 AC / 43.4%EXISTING PERVIOUS AREA1.28 AC / 56.6%PROPOSED IMPERVIOUS AREA1.51 AC / 67.1%PROPOSED PERVIOUS AREA0.74 AC / 32.9%MAXIMUM IMPERVIOUS LOTCOVERAGE70%NET INCREASE IN IMPERVIOUS AREA0.54 ACSITE DATAEXISTING ZONINGR-1 - MIXED RESIDENTIALPROPOSED ZONINGR-1 - MIXED RESIDENTIALPROPOSED LAND USESENIOR LIVINGPARKING SETBACKS4'BUILDING SETBACKSFRONT= 25'SIDE=12'REAR=25'
LEGEND
SITE PLAN NOTES1.REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONSOF STOOPS, TRUCK DOCKS, TRASH ENCLOSURES & PRECISE BUILDINGDIMENSIONS. REFER TO THE SITE ELECTRICAL PLAN FOR LOCATIONS OF PROPOSEDLIGHT POLES, CONDUITS, AND ELECTRICAL EQUIPMENT.2.REFER TO CERTIFIED SITE SURVEY OR PLAT FOR EXACT LOCATION OF EXISTINGEASEMENTS, PROPERTY BOUNDARY DIMENSIONS, AND ADJACENT RIGHT-OF-WAY &PARCEL INFORMATION.3.DIMENSIONS AND RADII ARE DRAWN TO THE FACE OF CURB, UNLESS OTHERWISENOTED. DIMENSIONS ARE ROUNDED TO THE NEAREST TENTH FOOT, AND AREASARE ROUNDED TO THE NEAREST SQUARE FOOT.4.UNLESS OTHERWISE NOTED, THE CONTRACTOR SHALL BE RESPONSIBLE FORRELOCATING EXISTING SITE IMPROVEMENTS THAT CONFLICT WITH THE PROPOSEDWORK, INCLUDING BUT NOT LIMITED TO TRAFFIC SIGNS, LIGHT POLES,ABOVEGROUND UTILITIES, ETC. PERFORM WORK IN ACCORDANCE WITHGOVERNING AUTHORITIES REQUIREMENTS AND PROJECT SITE WORKSPECIFICATIONS. COST SHALL BE INCLUDED IN BASE BID.5.TYPICAL PARKING STALL DIMENSIONS SHALL BE 10.0-FEET IN WIDTH AND 19-FEET INLENGTH UNLESS OTHERWISE INDICATED.6.MONUMENT SIGN(S) ARE DETAILED ON THE ARCHITECTURAL PLANS AND ARESHOWN FOR GRAPHICAL & INFORMATIONAL PURPOSES ONLY. CONTRACTOR TOVERIFY SIGN DIMENSIONS, LOCATION AND REQUIRED PERMITS WITH THE OWNER.
BUILDING DATATOTAL BUILDING AREA±25,400 SFPERCENT OF TOTAL PROPERTY AREA26.04%MAXIMUM BUILDING HEIGHT35 FTPARKING SUMMARYREQUIRED PARKING (1 STALL PERBEDROOM)67 SPACESTOTAL PROPOSED PARKING62 SPACES (PARKING LOT)18 SPACES (UNDERGROUND)REQUIRED ACCESSIBLE PARKING3 SPACESPROPOSED ACCESSIBLE PARKING7 SPACES
PROPOSED CURB AND GUTTERPROPERTY LINESETBACK LINESTANDARD DUTY ASPHALT PAVMENTSEE DETAILS FOR SECTIONHEAVY DUTY ASPHALT PAVEMENTSEE DETAILS FOR SECTIONHEAVY DUTY CONCRETE PAVEMENTSEE DETAILS FOR SECTIONSTANDARD DUTY CONCRETE PAVEMENT / SIDEWALKSEE DETAILS FOR SECTION
KEYNOTE LEGENDCURB, SIDEWALK & PAVEMENT6" CONCRETE CURB & GUTTER (B612) - SEE DETAILCONCRETE SIDEWALK - SEE DETAILACCESSIBLE CURB RAMP - SEE DETAILMATCH EXISTING EDGE OF PAVEMENT / CURB & GUTTERFLUSH CURB & GUTTER - SEE DETAILTRAINISTION FROM 6" TO FLUSH CURBCOMMERCIAL DRIVEWAY APRON - SEE DETAILSITE FIXTURESGUARDRAIL - SEE DETAILPAVEMENT MARKINGSACCESSIBLE PARKING SYMBOL & LOADING AREA - SEE DETAILSTRIPED WHITE CROSS-HATCH AREA 4" SOLID LINES @ 45° 2' O.C.4" WIDE WHITE PAINTED SOLID PARKING LOT LINEPAINTED WHITE DIRECTIONAL ARROWSIGNAGEADA PARKING SIGN IN BOLLARD - SEE DETAILREFERENCE NOTESAT-GRADE BUILDING ENTRY & STRUCTURAL STOOP - REFER TOARCHITECTURAL & STRUCTURAL PLANSTRANSFORMER/EQUIPMENT PAD - REFER TO MEP PLANSAT-GRADE GARAGE ENTRANCE - REFER TO ARCHITECTURAL &STRUCTURAL PLANSRETAINING WALL WITH FENCE / RAILING - REFER TOARCHITECTURAL & STRUCTURAL PLANSPATIO - REFER TO ARCHITECTURAL & STRUCTURAL PLANSHANGING PATIO - REFER TO ARCHITECTURAL & STRUCTURALPLANS
C1C2C3C4C5C5C6F1P1P2P3P4S1R1R2R3R4R5R6
RETAINING WALL WITH FENCEPROPOSED FENCE
NORTH0GRAPHIC SCALE IN FEET20102040Know what'sbelow.before you dig.Call
R
DATECHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT16136700005/08/2026AS SHOWNALCKAHALCPREPARED FORSITE DIMENSIONPLAN
C400PRESCOTT SENIOR LIVINGNOTTINGHAM CONSTRUCTIONPRESCOTTWI
LANDSCAPE KEYNOTESLANDSCAPE LEGENDEXISTING DECIDUOUS TREE (TYP.)EXISTING CONIFEROUS TREE (TYP.)EXISTING SHRUB (TYP.)EDGER (TYP.)APPROXIMATE LIMITS OF SEED/SOD, PROVIDESEED OR SOD TO ALL DISTURBED AREAS (TYP.)SEED/SOD EDGE (TYP.)ROCK MULCH (TYP.)SEED WITH CLASSIC TALLGRASS PRAIRIE SEEDMIX BY PRAIRIE MOON, OR APPROVED EQUAL(TYP.)SEED WITH FESCUE LOW GROW/NO MOW SEEDMIX BY JRK SEED (TYP.)
ALANDSCAPE KEYNOTESEDGER (TYP.)DOUBLE SHREDDED HARDWOOD MULCH (TYP.)ROCK MULCH (TYP.)SOD (TYP.)MAINTENANCE STRIP (TYP.)EXISTING TREE(S) TO REMAIN, PROTECT INPLACE (TYP.)
ABCDEF
PROPOSED BUILDINGFOOTPRINT± 25,400 SF1ST FLOOR FFE: 778.00BASEMENT FFE: 767.50
T
OAK STREET
COURT STREET
66'
PEACOCK RIDGE
PEACOCK RIDGE
MBTP TP TP
FENCEFENCEFENCE
FENCE
GATE
GUARD RAIL
EM
D
COCO
CO
CO
DCO
CO
D
D
D
D
CO
CO
CO
D
CO
E
D EAB
B BBB
BB
FF
F
NM TG
TG
AB
EB
D
D D
D
DAB
D
A
CA
B
AB
B
AB
CA
TG
DDD
D
D
D
NM
NM
NM
AB
EXISTINGRETAINING WALL
EXISTINGRETAINING WALL
EXISTINGRETAINING WALLEXISTINGRETAINING WALLEXISTINGRETAINING WALL
PROPOSEDRETAININGWALL, SEE CIVIL CODECOMMON NAMECONIFEROUS TREEBHSBLACK HILLS SPRUCEERCEASTERN RED CEDARWHPWHITE PINEORNAMENTAL TREEDAKDAKOTA PINNACLE BIRCHPRCPRAIRIE ROSE CRABAPPLEQUAQUAKING ASPENOVERSTORY TREEACLNORTHERN ACCLAIM® HONEY LOCUSTNWMNORTHWOOD MAPLERDLREDMOND AMERICAN LINDENSGMSIENNA GLEN MAPLESWOSWAMP WHITE OAKCONIFEROUS SHRUBSMDJMEDORA JUNIPERMGPMUGO PINEMJJMINT JULEP JUNIPERSPJSPARTAN JUNIPERTCATECHNY ARBORVITAEDECIDUOUS SHRUBSBLCIROQUOIS BEAUTY BLACK CHOKEBERRYIWHINCREDIBALL WHITE HYDRANGEAKOHKODIAK ORANGE BUSH HONEYSUCKLELDNLITTLE DEVIL NINEBARKRTDRED TWIG DOGWOODSSWSUMMERSWEETORNAMENTAL GRASSESFLGFLAME GRASSKFGKARL FOERSTER FEATHER REED GRASSPERENNIALSBESBLACK-EYED SUSANLSSLITTLE SPIRE RUSSIAN SAGEOCBOBSIDIAN CORAL BELLSRHARHINELAND ASTIBLESBOSUMMER BEAUTY ORNAMENTAL ONION
PLANT KEY
SEEDING KEYNOTESSEED WITH CLASSIC TALLGRASS PRAIRIE SEED MIX BY PRAIRIE MOON, ORAPPROVED EQUAL (TYP.)SEED WITH FESCUE LOW GROW/NO MOW SEED MIX BY JRK SEED (TYP.)TGNM
This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.SHEET NUMBER
K:\TWC_LDEV\Nottingham Construction\Prescott, WI Assisted Living\3 Design\CAD\PlanSheets\L1-LANDSCAPE PLAN.DWG May 08, 2026 - 8:30am
BYREVISIONSNo.DATE 2025 KIMLEY-HORN AND ASSOCIATES, INC.767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114PHONE: 651-645-4197WWW.KIMLEY-HORN.COM©PRELIMINARY - NOT FOR CONSTRUCTION
REQUIRED CANOPY TREES:21 TREES = (662 L.F. FRONT LOT LINE - 25 L.F. DRIVEWAY - 25 L.F. DRIVEWAY) / 30PROVIDED CANOPY TREES:23 TREESREQUIRED SHRUBS:123 SHRUBS = (662 L.F. FRONT LOT LINE - 25 L.F. DRIVEWAY - 25 L.F. DRIVEWAY) / 30 * 6PROVIDED SHRUBS:182 SHRUBSREQUIRED PARKING LOT TREES:8 TREES = 218 L.F. PARKING LOT PERIMETER / 30PROVIDED PARKING LOT TREES:8 TREESREQUIRED PARKINGLOT SHRUBS:LOW SHRUBS TO FORM A CONTINUOUS SCREEN AT LEAST 30 INCHES HIGH WITHIN THREE YEARS AND MAINTAINED AT A HEIGHT NOT TO EXCEED 42 INCHES.PROVIDED PARKINGLOT SHRUBS:87 PROPOSED SHRUBS TO FORM A CONTINUOUS SCREEN AT LEAST 30 INCHES HIGH WITHIN THREE YEARS AND MAINTAINED AT A HEIGHT NOT TO EXCEED 42 INCHES.TOTAL REQUIRED TREES:21 TREESTOTAL REQUIRED SHRUBS:123 SHRUBSTOTAL PROVIDED TREES:36 TREESTOTAL PROVIDED SHRUBS:182 SHRUBS
LANDSCAPE SUMMARY
Know what'sbelow.before you dig.Call
NOTE:SEE L102 FOR FULL SCHEDULE AND QUANTITIES.
NORTH0GRAPHIC SCALE IN FEET20102040
DATECHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT16136700005/04/2026AS SHOWNATKATKRAHPREPARED FORLANDSCAPE PLAN
L100PRESCOTT SENIOR LIVINGNOTTINGHAM CONSTRUCTIONPRESCOTTWI
PORTION OF ELEVATION ANGLED - SHOWN STRAIGHT FOR CLARITY
FIRST FLOOREL: 100'-0"
TRUSS BRG.EL: 109'-1 1/8"SECOND FLOOREL: 111'-2 5/8"
TRUSS BRG.EL: 120'-3"
812812812
125
LP SMARTSIDING6" LAP, TYP
LP SMARTSIDING - 8" LAP, TYPSTONE VENEER, TYP
COMPOSITE SHAKESIDING, TYPASPHALT SHINGLES, TYP
VINYL WINDOWS, TYP
PRE-FINISHED METALGUTTER & DOWNSPOUT, TYPPRE-FINISHED METALFASCIA, TYP
ALUMINUM ENTRANCEDOORS, TYPVINYL PATIO DOORS, TYPTRIM BOARDS, TYP
LP SMARTSIDING - 6" LAP, TYP
LP SMARTSIDING - 8" LAP, TYPSTONE VENEER, TYP
COMPOSITE SHAKESIDING, TYPASPHALT SHINGLES, TYP
VINYL WINDOWS, TYP
PRE-FINISHED METALGUTTER & DOWNSPOUT, TYP
PRE-FINISHED METALFASCIA, TYP
FIRST FLOOREL: 100'-0"
TRUSS BRG.EL: 109'-1 1/8"SECOND FLOOREL: 111'-2 5/8"
TRUSS BRG.EL: 120'-3"
125812812 812812
ALUMINUM ENTRANCEDOORS, TYP VINYL PATIO DOORS, TYPTRIM BOARDS, TYP
2000 44TH ST. S., #102FARGO, ND 58103701-893-3839
SHEET: ASSISTED LIVINGPRESCOTT, WI
PROJECT:
SHEET CONTENTS:CHECKED BY:SCHEMATIC SETDRAWN BY:
REVISIONS:No. DATE REMARK
DATE:PROJECT NO:NGVJUNE 5, 202625-014
DOCUMENT PHASE:NOT FOR CONSTRUCTION
MEM
BUILDINGELEVATIONS
A1.6
SCALE: 1/16" = 1'-0"SOUTH BUILDING ELEVATION - OVERALL1
SCALE: 1/8" = 1'-0"SOUTH BUILDING ELEVATION - PARTIAL2
SCALE: 1/8" = 1'-0"SOUTH BUILDING ELEVATION - PARTIAL3
PORTION OF ELEVATION ANGLED - SHOWN STRAIGHT FOR CLARITY
FIRST FLOOREL: 100'-0"
TRUSS BRG.EL: 109'-1 1/8"SECOND FLOOREL: 111'-2 5/8"
TRUSS BRG.EL: 120'-3"
BASEMENTEL: 89'-5"
FIRST FLOOREL: 100'-0"
TRUSS BRG.EL: 109'-1 1/8"SECOND FLOOREL: 111'-2 5/8"
TRUSS BRG.EL: 120'-3"
BASEMENTEL: 89'-5"
812812812
125
ALUMINUM ENTRANCEDOORS, TYP
COMPOSITE SHAKESIDING, TYPASPHALT SHINGLES, TYP
VINYL WINDOWSLP SMARTSIDING - 8" LAP, TYP
PRE-FINISHED METALGUTTER & DOWNSPOUT, TYP
TRIM BOARDS, TYP
LP SMARTSIDING - 6" LAP, TYPPRE-FINISHED METALFASCIA, TYP
FIRST FLOOREL: 100'-0"
BASEMENTEL: 89'-5"
TRUSS BRG.EL: 109'-1 1/8"SECOND FLOOREL: 111'-2 5/8"
TRUSS BRG.EL: 120'-3"
125
812812
LP SMARTSIDING - 6" LAP, TYP
PRE-FINISHED METALFASCIA, TYP
LP SMARTSIDING - 8" LAP, TYPALUMINUM ENTRANCEDOORS, TYP
COMPOSITE SHAKESIDING, TYPASPHALT SHINGLES, TYP
VINYL WINDOWS
PRE-FINISHED METALGUTTER & DOWNSPOUT, TYP
TRIM BOARDS, TYP
2000 44TH ST. S., #102FARGO, ND 58103701-893-3839
SHEET: ASSISTED LIVINGPRESCOTT, WI
PROJECT:
SHEET CONTENTS:CHECKED BY:SCHEMATIC SETDRAWN BY:
REVISIONS:No. DATE REMARK
DATE:PROJECT NO:NGVJUNE 5, 202625-014
DOCUMENT PHASE:NOT FOR CONSTRUCTION
MEM
BUILDINGELEVATIONS
A1.7
SCALE: 1/8" = 1'-0"NORTH BUILDING ELEVATION - PARTIAL2
SCALE: 1/8" = 1'-0"NORTH BUILDING ELEVATION - PARTIAL3
SCALE: 1/8" = 1'-0"NORTH BUILDING ELEVATION - OVERALL1
2000 44TH ST. S., #102FARGO, ND 58103701-893-3839
SHEET:ASSISTED LIVINGPRESCOTT, WIPROJECT:
SHEET CONTENTS:CHECKED BY:CONSTRUCTION SETDRAWN BY:
REVISIONS:No. DATE REMARK
DATE:PROJECT NO:NGVNOV 3, 202525-014DOCUMENT PHASE:NOT FOR CONSTRUCTION
MEMPRELIMINARYRENDERINGA2.3
SCALE: N.T.S.PRELIMINARY RENDERING1
Menomonie | Madison | Green Bay
engineers | architects | planners | environmental specialists
land surveyors | landscape architects | interior designers
MEMO
604 Wilson Avenue
Menomonie, WI 54751
715-235-9081
800-472-7372
FAX 715-235-2727
Matt and Luke,
I received the Stormwater Management Report and HydroCAD files for the 445 Court Street project. I have
reviewed the stormwater management plan and have the following recommendations/comments. Bold
highlighted items require confirmation or revision.
• The site disturbs approximately 2.25 acres and will require a WDNR NOI per NR 216 and NR151.
• The storm water will be managed by a pre-designed underground storm water detention and
treatment system manufactured by ADS StormTech. The underground system is comprised of long
chambers made of HDPE material. There are 3 rows that are 8.3’ wide and 124’ long. The
chambers are 5’ tall. This system design is modeled by the manufacturer and the data is input into
the HydroCAD modeling software. The underground system provides post-development runoff rate
reduction, and total suspended solids removal. The underground stormwater treatment system is
located under the proposed parking lot on the east side of the building.
• The east side of the building roof, and the east parking lot drain to the underground stormwater
treatment system. The reduced rates leaving the underground stormwater treatment system are
piped to the existing storm manhole on the west side of the property, leading to the City of Prescott
storm sewer system.
• The Post-Developed runoff model shows the west side of the building roof (basin 4S)
draining to the underground stormwater treatment system. The plans show it connecting
storm sewer system on the west side of the site. The engineer must verify the correct
modeling of the west side of the building roof.
DATE: June 25, 2026
TO: Matt Wolf and Luke Wiese, City of Prescott
FROM: Greg Adams
REGARDING: Review of 445 Court Street – Stormwater Management Report
PROJECT #:
• The Pre-Developed and Post-Developed runoff rates were calculated for the 1.5” rainfall event, the 2
year, 10 year and 100 year rainfall events. Table 2 below represents the Pre-Development and Post-
Development runoff draining to the existing storm manhole and 12” storm sewer on the west side of
the site toward the Peacock Ridge development. The Post-Development rates for all rainfall events
are less than the existing Pre-Development rates. The engineer must verify that these rates
reflect the correct modeling of the west side of the building roof.
Percent reduction - 8.5% - 66.3% - 30.5% - 20.6%
• Table 3 below represents the Pre-Development and Post-Development runoff draining overland
offsite to the west property line. The Post-Development rates for all rainfall events are less than the
existing Pre-Development rates. The engineer must verify that these rates reflect the correct
modeling of the west side of the building roof.
Percent reduction - 100% -73.3% -54.3% -40.0%
• Table 4 below represents the stormwater quality treatment results. The City and the WDNR require
redevelopment sites to meet 40% total suspended solids (TSS) removal. The stormwater quality
modeling shows the total suspended solids removal rate of 43.6%.
To: Plan Commission
From: Luke Wiese, City Planner
Date: July 2nd, 2026
Subject: CSM for Division of Parcel in SW 1/4 of the SW 1/4 of Section 3, Township 26N, Range
20W
Background
Ed Lucas, the owner of the property located in the SW 1/4 of the SW 1/4 of Section 3, Township 26N,
Range 20W in the City of Prescott, has submitted a preliminary certified survey map (CSM). This CSM
proposes dividing the parcel into two lots.
The CSM was prepared in October 2024 but was never brought before the Plan Commission or City
Council because a planning application was not submitted at that time. The City has now received a
complete application. Staff has reviewed the CSM and has not identified any changes to the
applicable zoning regulations or other City requirements that would affect the proposed land division
since the CSM was prepared.
• Lot 1 (501 Sunset Ct): 1.28 acres
• Lot 2 (1201 Pearl St): 0.6997 acres
Both lots meet the minimum lot size requirements for the R-1 district. Lot 1 will become part of the
adjacent parcel to the south, addressed as 501 Sunset Ct, while Lot 2 will become a standalone lot
addressed as 1201 Pearl Street.
Land divisions within the Lower St. Croix (LSCR) National Scenic Riverway typically require a
conditional use permit for residential purposes, as outlined in Section 606-21. However, this CSM
creates the following conditions:
• Lot 1: Already contains a principal structure, so no additional residential structure is
permitted by right.
• Lot 2: Buildable area is located outside the LSCR National Scenic Riverway, allowing a
residential structure to be permitted by right, subject to compliance with zoning code
regulations.
Based on staff's assessment, the proposed CSM does not require a conditional use permit.
Discussion
The proposed division aligns with applicable ordinances and state statutes. Staff reviewed the CSM
for compliance with the City of Prescott’s Chapter 510-13 ordinance, 606-21, and Wis. Stat. 236.34
and found it to meet all requirements.
Recommendation
Staff recommends forwarding the enclosed resolution for the division of the parcel in the SW 1/4 of
the SW 1/4 of Section 3, Township 26N, Range 20W to Council for review.
Attachments
1. Certified Survey Map Sheet 1
2. Certified Survey Map Sheet 2
3. RESOLUTION XX-26 CSM Division of Parcel in SW 14 of the SW 14 of Section 3, Township 26N,
Range 20W
501 Sunset Court Prescott WI 54021Edward LucasSHEET 1 OF 2 SHEETS
I
NAL SDEau GalleBrandon W.S-2632WIKingSWIOCNS
RUOEYVR
N
EMAIL: BKLSLLC@GMAIL.COMPREPARED FOR:
CERTIFIED SURVEY MAP
The bearings shown hereon are based on the Pierce CountyCoordinate System NAD 1983, (91) adjustment. The west lineof the SW 1/4 bears N00-16-00W. Bearings are expressed indegrees-minutes-seconds and distances are expressed indecimal feet. See County Surveyor's Office for section data.
1 INCH= 80 FEET. SCALE IN FEET.
BRANDON KING LAND SURVEYING, LLCN324 COUNTY ROAD D SUITE A EAU GALLE WI 54737PHONE: 715-639-5243
DENOTES A FOUND COUNTY MONUMENT.
Located in part of the SW 1/4 of the SW 1/4 of Section 3, Township 26 North,Range 20 West, City of Prescott, Pierce County, Wisconsin .
FIELDWORK DATE: 10-16-2024MAP DATE: 10-17-2024
CSM NO. __________VOL.__________ PG. __________
10-17-2024
WCMC3-T26N-R20WFound Alum. Cap
DENOTES A FOUND 1" O.D. IRON PIPE.(XXX) DENOTES RECORDED AS.
Lot 1 CSMV. 3, P. 126
DENOTES A FOUND MAGNAIL.
unplatted lands
Sunset Court
LOT 1
housewell shed
shed
garageN00-16-00W 1336.16
474.61
563.85
N00-16-00W 297.71
110.76
186.95
S89-58-14E 382.29191.14191.154.34185.80
S00-40-53E 75.28
N01-08-40W 149.65
SW Corner3-T26N-R20WFound Cast Iron Mon.
2.88191.43
ROD WEIGHING 1.50 LBS. PER LINEAL FT.DENOTES A PLACED 3/4" BY 18" IRON
66
50centerline
centerlinePearl Street
unplatted lands
LOT 2
Lot 9 CSMV. 16, P. 5Lot 7 CSMV. 13, P. 36Lot 1 CSMV. 3, P. 193unplatted landsunplatted lands
fence
fence falls 5±east of linefence falls 4.6±east of line
56,028 Sq. Feet1.2862 Acres30,477 Sq. Feet0.6997 Acres
SW 1/4 of SW 1/4 3-T26N-R20WNotes:This is a land transfer between adjoining landowners and no new parcels are being created.Lots 1 & 2 represent lands described in DocumentNumbers 310649 & 570287.
(N01-57-00W)
(N88-23-00E 384.20)
(S00-48-00W)(West)(N46-57-00W 22.74)(S43-03-00W 50.00)
(S46-57-00E 50.00)(S01-57-00E 74.64)(S88-07-00W 194)(475)
(110)
(184.80)
S89-31-26W 166.49S02-07-43W 163.39
S89-23-37W 194.31
SURVEYOR'S CERTIFICATEI, Brandon W. King, Wisconsin Professional Land Surveyor, hereby certify that I have surveyed, divided and mappeda parcel of land being in the SW 1/4 of the SW 1/4 of Section 3, Township 26 North, Range 20 West, City of Prescott,Pierce County, Wisconsin, described as follows:Commencing at the southwest corner of said Section 3; thence N00-16-00W, along the west line of the SW 1/4,474.61 feet to the point of beginning of the lands to be described; thence continue N00-16-00W, along said west line,297.71 feet; thence S89-58-14E, 382.29 feet to the right of way line of Pearl Street; thence S02-07-43W, along saidline, 163.39 feet; thence S89-31-26W, along the right of way line of Sunset Court, 166.49 feet; thence N45-51-39W,along said line, 21.74 feet; thence S43-45-27W, along said line, 50.14 feet; thence S45-43-36E, along said line,49.34 feet; thence S00-40-53E, 75.28 feet; thence S89-23-39W, 194.31 feet to the point of beginning.Subject to all easements and restrictions of record.That I have made such survey, land division and map by the direction of the Edward Lucas, representative of theland, that such map is a correct representation of the exterior boundaries of the land surveyed and the map madethereof and that I have fully complied with the City of Prescott Subdivision Ordinance and the provisions of Chapter236.34 of the Wisconsin Statutes in surveying, dividing and mapping the same._________________________________Brandon W. King S-2632Wisconsin Professional Land SurveyorN324 County Road DEau Galle WI 54737
SHEET 2 OF 2 SHEETSEMAIL: BKLSLLC@GMAIL.COM
CERTIFIED SURVEY MAP
BRANDON KING LAND SURVEYING, LLCN324 COUNTY ROAD D SUITE A EAU GALLE WI 54737PHONE: 715-639-5243
I
NAL SDEau GalleBrandon W.S-2632WIKingSWIOCNS
RUOEYVR
N
10-17-2024
CSM NO. __________VOL.__________ PG. __________
CITY OF PRESCOTT COMMON COUNCIL RESOLUTIONResolved that this Certified Survey Map, attached hereto and filed with the City of Prescott, Wisconsin, by Edward Lucas,representative of the land, is hereby approved by the Plan Commission and the Common Council of the City of Prescott, Wisconsin.Approved by:PLAN COMMISSION AND COMMON COUNCILCity of Prescott, WisconsinDate:_____________________Approved______________________________________City of Prescott MayorI hereby certify that the forgoing Resolution was adopted by the Plan Commission and Common Councilof the City of Prescott, Wisconsin, on the ___________ day of ______________________, 2024.__________________________________City of Prescott Clerk
Located in part of the SW 1/4 of the SW 1/4 of Section 3, Township 26 North,Range 20 West, City of Prescott, Pierce County, Wisconsin .
RESOLUTION XX-26
RESOLUTION APPROVING A CERTIFIED SURVEY MAP SUBDIVIDING A PARCEL IN SW
14 OF THE SW 14 OF SECTION 3, TOWNSHIP 26N, RANGE 20W
WHEREAS, a certified survey map prepared and recorded in accordance with the City’s subdivision
ordinance and chapter 236, Wis. Stats.; and
WHEREAS, in Prescott, subdivisions are reviewed by Plan Commission and approved by City Council.
To Comply with 236.34(1), the submitted CSM shall go through the same process; and
WHEREAS City staff reviewed the CSM against the subdivision ordinance and the Wisconsin Platting
Manual and found it to be in conformance with both and recommends approval by Plan Commission; and
WHEREAS, the Plan Commission considered the CSM on July 8th, 2026 and recommended City
Council approval.
NOW, THEREFORE, BE IT RESOLVED, that the Common Council hereby approves the enclosed
CSM that divides a Parcel in SW 14 of the SW 14 of Section 3, Township 26N, Range 20W
Adopted this 13th day of July 2026.
_____________________________
Michael H. Gerke, Mayor
ATTEST:
_____________________________
Rashel Temmers, City Clerk
To: Plan Commission
From: Luke Wiese, Planner
Matt Wolf, City Administrator
Date: July 2, 2026
Subject: Conditional Uses – Request for Public Hearing
Background
At its last meeting, the Plan Commission reviewed the list of conditional uses currently
identified in Chapter 635 of the City Code. Under Wisconsin law, if a use is listed as a
conditional use within a zoning district, the ordinance recognizes that the use is generally
appropriate for that district. As a result, an application for a conditional use permit must be
approved if the applicant demonstrates compliance with the standards and conditions
established by the zoning ordinance. Conversely, the permit may be denied if the applicant
fails to meet those standards or conditions.
Based on that review, the Plan Commission recommended the following amendments to
Chapter 635 – Zoning:
• C-1 Central Commercial: Remove Large-Scale Solar Farms as a conditional use.
• I-1 Light Industrial: Remove Large-Scale Solar Farms as a conditional use.
• I-2 Heavy Industrial: Remove Airports, Airstrips, and Landing Fields; Railroads and
Railroad Facilities; and Large-Scale Solar Farms as conditional uses.
• I-3 Mixed Industrial: Remove Large-Scale Solar Farms as a conditional use.
• R-5 Single-Family Residential: Add Accessory Dwelling Units (ADUs) as a conditional
use.
Discussion
Staff has prepared the proposed amendments to the applicable sections of Chapter 635. For
ease of review, all proposed changes are highlighted in yellow.
Because these amendments modify the City's zoning ordinance, Wisconsin law requires that a
public hearing be held following publication of a Class 2 Notice.
Staff is requesting that the Plan Commission review the proposed amendments to confirm they
reflect the Commission's direction and, if appropriate, approve scheduling a public hearing for
the August 3, 2026, Plan Commission meeting.
Recommendation
1. Consider approval of scheduling a public hearing on the proposed amendments
to Chapter 635 – Zoning regarding conditional uses at the August 3, 2026, Plan
Commission meeting.
Attachments
1. C-1 Central Commercial Code Changes
2. I-1 Light Industrial Code Changes
3. I-2 Heavy Industrial Code Changes
4. I-3 Mixed Industrial Code Changes
5. R-5 Single-Family Residential Code Changes
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
§ 635-21. Central Commercial District C-1.
A. Purpose. The Central Commercial District is established to delineate areas appropriate for
commercial uses in and near the central business district or areas of similar compact
development served or readily serviceable by public sewer and water.
B. Principal permitted uses. Business services, such as bakeries, barber shops, bars, beauty
shops, clinics, clothing stores, clubs, drugstores, eating and drinking establishments, fish
markets, florists, food lockers, fruit and vegetable stores, gas stations, gift stores, grocery
stores, hardware stores, hotels, hobby shops, laundries, lodges, meat markets, motels, inns,
music stores, office supplies, optical stores, packaged beverage stores, places of
entertainment, professional, governmental and business offices, retail stores, finance, real
estate services, personal service establishments and funeral homes, the preceding by way of
illustration and not exclusion.
C. Accessory uses. Dwelling units as a part of the principal building not to exceed 50% of the
usable floor area, parking areas and garage. Dwelling unit shall be on a floor other than the
main floor.
D. Conditional uses.
(1) Residential buildings as a principal use.
(2) Structures or alteration of natural terrain on slopes of 20% or greater.
(3) Electric vehicle charging station in accordance with Article XII.
(4) Large-scale solar farms in accordance with Article IX.
(5) Drive-in establishment for eating and drinking.
(6) Other uses not specifically permitted, but similar in character to principal permitted
uses.
E. (Reserved)
F. Prohibited uses: other uses not specified and in accordance with § 635-9E.
G. Minimum lot width: 25 feet for fireproof construction, 45 feet for non-fireproof construction.
H. Minimum lot depth: 100 feet.
I. Minimum yards.
(1) Front: none beyond City right-of-way.
(2) Rear: none for fireproof construction, 10 feet for non-fireproof construction. [Amended
5-13-2024 by Ord. No. 03-24]
(3) Side: none for fireproof construction, 10 feet for non-fireproof construction.
J. Maximum building height: 35 feet.
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
§ 635-21 § 635-21
K. Percent slope. No structures or alteration of natural terrain shall be permitted on slopes of
20% or greater, except as a conditional use.
L. Parking and loading requirements. See Article VI.
M. Performance standards. All uses of land, water and structures in this district must also comply
with Article VIII.
N. Modifications. Requirements stipulated above may be modified in accordance with § 635-11.
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
§ 635-23. I-1 Light Industrial District.
A. Purpose. The I-1 District is intended to provide for light industrial and manufacturing in areas
separated from other sections of the community. All residential uses are prohibited.
B. Principal permitted uses.
(1) Wholesaling and all C-1 District and C-2 District uses.
(2) Industries that do not cause or create odors and noises or pose traffic or health problems.
(3) Public facilities and uses including:
(a) Governmental, cultural and public buildings or uses, such as fire and police
stations, community centers, libraries, public emergency shelters, parks,
playgrounds and museums.
(b) Schools and churches.
(4) Other industries consistent with the definition and purpose of the I-1 District.
C. Accessory uses.
(1) Essential services.
(2) Sales, showrooms and demonstration areas.
(3) Electric vehicle charging station in accordance with Article XII.
D. Conditional uses.
(1) Structures or alteration of natural terrain on slopes of 20% or greater.
(2) Large-scale solar farms in accordance with Article IX.
E. Prohibited uses: residential housing or other uses not specified and in accordance with
§ 635-9E.
F. Minimum lot area: 8,000 square feet.
G. Maximum building height: 35 feet.
H. Minimum setback.
(1) Front: 25 feet.
(2) Rear: 15 feet if property abuts other industrial or commercial property; 40 feet if
property abuts residential property.
(3) Side: 20 feet on each side.
I. Minimum lot width: 100 feet.
J. Sanitary criteria. When, as determined by the Common Council, no public sanitary sewer is
available, no more than 75% of the minimum lot area shall be on a slope greater than 12% of
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
§ 635-23 § 635-23
soil conditions unsuitable for septic tanks. At least 25% of the lot area shall be under 12%
and with solid suitable for septic tanks. There is a five-acre minimum lot size.
K. Percent slope. No structures or alteration of natural terrain shall be permitted on slopes of
20% or greater, except as conditional use.
L. Parking and loading requirements. See Article VI.
M. Performance standards. All uses of land, water and structures in this district must also comply
with Article VIII.
N. Modifications. Requirements stipulated above may be modified in accordance with § 635-11.
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-02
§ 635-24. I-2 Heavy Industrial District.
A. Purpose. The Heavy Industrial District is intended to provide an area for manufacturing and
industrial activities. It is also intended to provide an area for a variety of uses which require
relatively large installations, facilities or land areas; which would create or tend to create
conditions of public or private nuisance, hazard or other undesirable conditions; or which for
these or other reasons may require special safeguards, equipment, processes, barriers or other
forms of protection, including spatial distance, in order to reduce, eliminate or shield the
public from such conditions.
B. Principal permitted uses.
(1) Manufacturing establishments, usually described as factories, mills or plants in which
raw materials are transformed into finished projects, and establishments engaged in
assembling component parts of manufactured products.
(2) Wholesale establishments and warehouses.
(3) Highway passenger and motor freight transportation.
(4) Construction trades, including building contractors, concrete plants, landscaping and
similar operations.
(5) Light industry and service uses.
(6) Other industrial and commercial activities of similar type and character.
C. No more than 70% of the total area of the lot can be impervious.
D. Accessory uses.
(1) Essential services.
(2) Electric vehicle charging station in accordance with Article XII.
E. Conditional uses. The following may be permitted as conditional uses within the I-2 District.
Such uses shall be subject to the consideration of the Common Council and Plan Commission
with regard to such matters as the creation of nuisance conditions for the public or for the
users of nearby areas, the creation of traffic hazards, the creation of health hazards, or other
factors:
(1) The outdoor storage of industrial products, machinery, equipment, or other materials,
provided that such storage is enclosed by a suitable fence or other manner of screening.
(2) Railroads, including right-of-way, railroad yards, and structures normally incident to the
operation of railroads, including station houses, platforms, and signal towers, but not
including warehouses owned by companies other than railroad companies or road
terminal companies.
(3) Public facilities and uses, including airports, airstrips and landing fields.
(4) Agriculture-related industry and service uses.
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-02
§ 635-24 § 635-24
(5) Structures or alteration of natural terrain on slopes of 20% or greater.
(6) Large-scale solar farms in accordance with Article IX.
F. Minimum lot area: 8,000 square feet.
G. Maximum building height: 35 feet.
H. Minimum yards:
(1) Front: 25 feet.
(2) Rear: 15 feet if property abuts other industrial or commercial property; 40 feet if
property abuts residential property.
(3) Side: 20 feet on each side.
I. Minimum lot width: 100 feet.
J. Sanitary criteria. When, as determined by the Common Council, no public sanitary sewer is
available, no more than 75% of the minimum lot area shall be on a slope greater than 12% of
soil conditions unsuitable for septic tanks. At least 25% of the lot area shall be under 12%
and with solid suitable for septic tanks. There is a five-acre minimum lot size.
K. Percent slope. No structures or alteration of natural terrain shall be permitted on slopes of
20% or greater, except as conditional use.
L. Parking and loading requirements. See Article VI.
M. Performance standards. All uses of land, water and structures in this district must also comply
with Article VIII.
N. Modifications. Requirements stipulated above may be modified in accordance with § 635-11.
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
§ 635-25. I-3 Mixed Industrial - Commercial District.
A. Purpose. The I -3 District is provided to accommodate those light industrial uses and
commercial uses compatible with one another and often located separate from general retail
business centers and that will maintain high standards of site planning, architecture, and
landscaping design.
B. Principle permitted uses.
(1) Any principal use permitted within the I-1 District.
(2) General retail stores.
(3) Medical offices (including physicians, dental, chiropractic, physical therapy, and
optometry).
(4) Legal.
(5) Real estate offices.
(6) Counseling.
(7) Financial institutions (banks, credit unions, and brokerages).
(8) Insurance.
(9) Travel agency.
(10) Business services (consulting, computer, and employment).
(11) Accounting.
(12) Engineering.
(13) Post office.
(14) Telephone/telecommunications operations.
(15) Printing.
(16) Educational functions (technical school, community colleges, etc.).
(17) Federal, state, or local government offices.
(18) Office showrooms.
(19) Funeral homes and crematoriums.
(20) Hotel, motel, and inns.
(21) Eating and drinking establishments.
(22) Gas stations and automobile services.
(23) Grocery stores.
City of Prescott, WI
§ 635-25 § 635-25
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
(24) Hardware stores.
(25) Logistics.
(26) Manufacturing.
(27) Wholesaling.
C. Accessory uses. Any use that is clearly accessory to any of the above permitted uses except
those that are unreasonably dangerous or generate noise, light, smoke, air, or water pollution
that would create a public or private nuisance. Accessory uses include but are not limited to
day care within the company or business, warehousing up to 70% of the gross floor area of
the business, sales, showrooms, and demonstration areas.
(1) Electric vehicle charging station in accordance with Article XII.
D. Conditional uses.
(1) Structures or alteration of natural terrain on slopes of 20% or greater.
(2) Veterinarian clinic.
(3) Child/elder care facilities (freestanding).
(4) Warehouse in excess of 70% of permitted business.
(5) Large-scale solar farms in accordance with Article IX.
E. Prohibited uses and in accordance with § 635-9E.
(1) Any use that creates noise, dust, smoke, air, or water pollution or is a hazard to the
public.
(2) Outside storage.
(3) Wastewater treatment facilities.
(4) Any use generally classified as heavy industrial uses.
(5) Residential housing.
F. Minimum lot area: 8,000 square feet.
G. Minimum yards.
(1) Front or street: 25 feet on front and side yards.
(2) Rear: 15 feet if property abuts other industrial or commercial property; 40 feet if
property abuts residential property.
(3) Side (non street): 20 feet.
H. Minimum lot width: 100 feet.
I. Percent slope. No structure or alteration of natural terrain shall be permitted on slopes of 20%
City of Prescott, WI
§ 635-25 § 635-25
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
or greater, except as a conditional use.
J. No more than 70% of the total area of the lot can be impervious.
K. Parking and loading requirements. See Article VI.
L. Modifications. Requirements stipulated above may be modified in accordance with § 635-11.
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
§ 635-20. Single-Family Residential District (R-5). [Amended 8-11-2025 by Ord. No. 06-25]
A. Purpose. The Single-Family Residential District is intended to provide a quiet, pleasant living
area of single -family homes protected from traffic, congestion and incompatible land uses.
This district shall be located in areas presently served or readily serviceable by public sewer
and water.
B. Principal permitted uses.
(1) Single-family homes only.
(2) Neighborhood park or playground.
C. Accessory uses.
(1) One private garage and accessory building.
(2) Essential services.
(3) Electric vehicle charging station in accordance with Article XII.
(4) Solar energy systems in accordance with Article IX.
D. Conditional uses.
(1) Professional home offices, home occupations.
(2) Structures or alteration of natural terrain on slopes of 20% or greater.
(3) In-home day-care centers, nursing homes.
(4) Bed-and-breakfast establishments.
(5) Churches, schools, libraries, hospitals, community centers, cemeteries.
(6) Municipal buildings.
(7) Public utility structures, provided they are enclosed in an eight-foot or higher protection
fence.
(8) Day-care centers.
(9) Accessory dwelling unit in accordance with § 635-49.
E. (Reserved)
F. Prohibited uses. All uses not specifically permitted and in accordance with § 635-9E.
G. Minimum lot area: 10,000 square feet per dwelling unit.
H. Minimum lot width: 75 feet.
I. Minimum dwelling width: 22 feet.
J. Minimum yards.
(1) Front: 25 feet from City right-of-way line or in line with existing houses.
City of Prescott, WI
Downloaded from https://ecode360.com/PR2989 on 2026-07-01
§ 635-20 § 635-20
(2) Rear: 25 feet.
(3) Side: eight feet minimum, 20 feet total; five feet on each side for accessory structures.
K. Maximum building height: 35 feet.
L. Minimum dwelling unit size: 575 square feet.
M. Maximum lot coverage. No more than 70% of the total area of the lot can be impervious.
N. Percent slope. No structures or alteration of natural terrain shall be permitted on slopes of
20% or greater, except as a conditional use.
O. Parking and loading requirements. See Article VI.
P. External lighting. All exterior lighting shall minimize light pollution by providing the
minimum value of light necessary for comfort, safety, and identification of features.
Q. Modifications. Requirements stipulated above may be modified in accordance with § 635-11.
Source: City of Prescott website. First collected Oct 9, 2026.