Planning & Zoning / Town Board — Agenda packet
Town of Eagle · Waukesha County · Planning & Zoning / Town Board · meeting of Jan 7, 2026 · Agenda packets
Open the original document More from Town of Eagle
Text
Extracted automatically from the original. Tables and formatting may not survive; the original document is authoritative.
JOINT PLANNING & ZONING COMMISSION AND TOWN BOARD MEETING
January 7, 2026, 5:30 PM
820 E. Main Street, Eagle WI 53119
Agenda
1. Call to Order, Pledge of Allegiance
2. Roll Call
3. Minutes – Plan Commission consideration/approval of December 3, 2025, meeting minutes
4. Minutes – Town Board consideration/approval of December 3, 2025, meeting minutes
5. Public Comments - Please be advised per Section 19.84(2) Wis. Stats., information will be received from
the public on only the items listed on the agenda. This public comment session shall last no longer than 15
minutes and individual presentations are limited to three minutes per speaker. There may be limited
discussion on the information received, however, no action will be taken under public comment.
6. Site Plan/Plan of Operation for a 9,000 sq. ft. addition on the north side of the UPI Manufacturing building
at S87W35670 Godfrey Ln. Tax Key 1818.999.053. Dretzka Investments, LLC (owner), UPI Manufacturing
(applicant) Application 2025-25; Additional Information is available at:
https://s.zoninghub.com/K9HKD2WX5D
A. Review and Discussion
B. Plan Commission recommendation to Town Board
C. Town Board action
7. Site Plan/Plan of Operation for a new 3,200 sq. ft. building at S90W35680 CTH NN. Tax Key 1818.999.003.
Dretzka Chapman Oil, Inc (owner), Robert Chapman (applicant) Application 2025-24; Additional
Information is available at: https://s.zoninghub.com/EF2T3PYVRM
A. Review and Discussion
B. Plan Commission recommendation to Town Board
C. Town Board action
8. Review of the number of accessory buildings allowed on a property at W377S10480 Betts Rd which is
within the County’s Shoreland Jurisdiction. Tax Key 1858.999.005. Doug and Linda Varrelmann (owners);
Application 2025-26; Additional Information is available at: https://s.zoninghub.com/EDOCLD17D5
A. Review and Discussion
B. Plan Commission action
9. Miscellaneous Updates
A. Violation updates
B. Town Chairperson updates
10. Recommendation for future agendas (no packet materials)
11. Next meeting date: anticipated February 4, 2026
12. Adjournment by Planning and Zoning Commission
13. Adjournment by Town Board
Posted by Town Clerk on ______________________
Please note, upon reasonable notice, efforts will be made to accommodate the needs of disabled individuals through appropriate aids
and services. For additional information or to request this service, contact Town of Eagle at 262-594-5800. Copies of the agenda and
packet materials may be obtained before the start of the meeting by contacting the Town Hall at (262) 594-5800 during regular office
hours.
TOWN OF EAGLE
PLANNING & ZONING COMMISSION HELD JOINTLY WITH THE TOWN BOARD
December 3, 2025, 5:30PM
Unapproved Minutes
A Joint Public Hearing between the Town of Eagle Planning and Zoning Commission, Town of
Eagle Board, and a Staff Representative of the Waukesha County Department of Parks and Land Use -
Planning and Zoning Division was opened at 5:30pm by Chairperson Mommaerts to consider
amendments to the Town of Eagle Zoning Map. The map update incorporates modified floodplain
boundaries that were adopted in 2024. The overall floodplain area within the town reduced in size with
FEMA’s floodplain map update. Therefore, some of the lands formerly zoned by Waukesha County are
now subject to the Town of Eagle Zoning Code. Affected properties are proposed to be zoned consistent
with their current use. Most affected properties are state land which will be zoned P-1 Public. Many
affected areas will remain zoned C-1 Conservancy District because the lands are wetlands. Planner
Heermans displayed a map showing the changes. The public hearing was closed at 5:34pm.
Chairperson Mommaerts called the meeting to order at 5:35pm and led with the Pledge of Allegiance. R.
Kugel, C. Mommaerts, R. Hajewski, D. Domagalski, D. Radtke, T. Samuels, and M. Bendler were
present. D. Knauer and T. Betts were excused. Also in attendance was Town Planner Jacob Heermans.
Consideration and Approval of Minutes: Motion by Kugel, seconded by Domagalski to approve the
meeting minutes of November 5, 2025, as presented. All in favor, motion carried.
Mommaerts opened the floor for public comments. Jerald Wisth of Juniper Lane said another dumpsite
has been identified on the Doman property west of Markham Road. Wisth also asked where the Town is
at with the 2045 Land Use Plan and lastly urged that Cobblestone Farms Development in the village is
not opened up to traffic at Juniper Lane.
Consideration of the zoning amendment to the Town of Eagle Zoning Map, incorporating
modified floodplain boundaries that were adopted in 2024. Application 2025-23. Plan Commission
motion by Samuels to accept the map. Second by Kugel. All in favor, motion carried. Town Board
motion by Mommaerts to accept the recommendation of the Plan Commission to accept the map. Second
by Hajewski. All in favor, motion carried.
Change in Topography review for the placement of spoils resulting from a proposed wetland
scrape project at W384S7460 CTH N, Tax Key EGLT 1757.999. Gordon Erikson (owner). It was
noted that some of the documents in the packet incorrectly listed the address as CTH NN. The correct
address is on CTH N, not NN. Planner Heermans summarized that the property is approximately 380
acres in size and is used for agricultural purposes. There is a large wetland on the east side of the
property. The petitioner is proposing two shallow scrapes within the wetland to enhance wildlife habitat.
The scrapes will be located within the county zoning jurisdiction; the resulting spoils will be spread in
the farmland to the west. Plan Commission motion by Samuels to approve the change in topography
based on the conditions in the planner’s report. Second by Bendler. All in favor, motion carried. Town
Board motion by Hajewski to allow the change in topography as recommended by the Plan Commission.
Second by Domagalski. All in favor, motion carried.
Consideration of Certified Survey Map to create three (3) residential parcels on the southeast
corner of Wilton Rd and STH 67. Tax Keys EGLT 1768.998.018 and EGLT 1768.998.013. Steven
and Tara Wilton (owners). Application 2025-19 Heermans summarized that the applicants are
proposing a Certified Survey Map to reconfigure two existing parcels, to create three residential lots.
Plan Commission motion by Radtke to approve the lot configuration on Highway 67 and Wilton Road.
Second by Samuels. All in favor, motion carried. Town Board motion by Kugel to accept the
recommendation by the Plan Commission and waive the requirement for the conceptual CSM. Second
by Domagalski. All in favor, motion carried.
Periodic review of conditional use for hobby kennel for 9 dogs located at S105W375611 Estate
Drive (EGLT 1857.008); Kallie Kestly and James Anderson (owners). Application 2025-22. Per
Planner Heermans, the application indicated the same dogs reside on the property and no complaints
have been received in the past twelve months. Plan Commission motion by Mommaerts to extend the
approval for an additional year based on the representations made by the petitioner at this meeting.
Second by Kugel. All in favor, motion carried. Town Board motion by Hajewski to extend the
conditional use of the hobby kennel by the recommendation of the plan Commission. Second by
Domagalski. All in favor, motion carried.
Business Park Detention Pond (Discussion only) Plan Commissioner Bendler has a large amount of
documentation that is being reviewed. Bendler and Domagalski will compile the information.
Violation updates: Planner Heermans reported on code violations in the Town.
Chairperson Updates: Mommaerts has nothing to report at this time.
Future agenda items: No recommendations were made.
Next meeting: Wednesday January 7, 2026, at 5:30PM.
Motion to adjourn Planning and Zoning made by Samuels, seconded by Bendler. All in favor. Planning
and Zoning adjourned at 6:02pm. Motion to adjourn Town Board made by Domagalski, seconded by
Hajewski. All in favor. Town Board adjourned at 6:02pm.
Respectfully submitted, Mercia Christian, Clerk
STAFF REPORT AND RECOMMENDATION
SITE PLAN/PLAN OF OPERATION
Date: January 7, 2026
To: Planning and Zoning Commission and Town Board
Owner: Dretzka Investments LLC, UPI Manufacturing (applicant)
Location: S87W35670 Godfrey Ln, Tax Key No. EGLT 1818.999.053
Jurisdiction: This property is located entirely within the Town’s zoning jurisdiction.
Zoning Classification: B-4 Mixed Business.
Existing Use: Manufacturing facility producing commercial and government (defense) products
Proposed Use: Site Plan, Plan of Operation review to construct a 9,000 SF building addition on the north side of the
building
Application(s): 2025-25 Site Plan/Plan of Operation - https://s.zoninghub.com/K9HKD2WX5D
Staff Analysis
The subject property is 5.43 acres in size and is located on Godfrey Ln, between Chapman Ln and Price Ln., in the
northern portion of the Town Business Park. The property comprises two lots which were combined via Certified
Survey Map (CSM) in 2012. The property contains a 68,885 SF manufacturing/office building which was originally
constructed in 2006 and subsequently added onto in 2012. UPI primarily manufactures, fabricates and assembles
military equipment but does produce commercial products as well.
The petitioners are proposing a 9,000 sq. ft addition on the north side of the building for the continued assembly and
shipping of armored vehicle parts. The addition will be constructed of prefinished metal panels to match the
existing building, and two (2) overhead doors are proposed, one on the west of the addition and one on the east side
of the addition. Hours of operation are typically 6 a.m. to 5 p.m. Monday through Friday with a maximum of 40
employees working in the building at any given time. The addition will add approximately 18 employees. The north
side of the property is fenced with a retractable gate and is not accessible to the public. The stormwater for the site
is directed to the private stormwater facility which is also owned by the petitioner. The addition meets the
requirements of the B-4 District.
Staff Recommendation:
Staff recommends conditional approval of the Site Plan/Plan of Operation to construct the proposed addition on
the north side of the existing building subject to the following conditions:
1. No changes to the site landscaping are proposed. The existing landscaping shall be maintained in perpetuity.
2. All work related to this project must comply with the plans approved by the town.
3. Prior to any construction taking place, a Zoning Permit and Building Permit must be issued by the Town
Page 2
Planner and Town Building Inspector.
4. Any outdoor storage shall be screened from the road and shall not create a nuisance for nearby property
owners or businesses . Outdoor storage shall be limited to business-related equipment, materials and
product and at no time shall any outdoor storage be rented out to the general public.
5. Any outdoor lighting shall be LED, full cutoff and motion activated.
6. All proposed signage, as applicable, shall be approved by the Building Inspector.
7. Prior to the issuance of the Zoning Permit, the Town Planner must be notified by the Town Engineer that the
development meets all provisions of the Storm Water Management Ordinance for the Town of Eagle.
8. Documentation shall be submitted to the Town Planner that the local Fire Inspector has inspected the
building for compliance with all local fire codes, prior to the issuance of an occupancy permit.
9. Documentation shall be submitted to the Town Planner that the Town Building Inspector has completed a
thorough inspection of the building for compliance with all building codes, prior to the issuance of an
occupancy permit. If state approved plans are required, a copy of said plans shall be submitted to the Town
Planner and Building Inspector for review and approval prior to the issuance of a Building Permit.
10. All activities on the subject property herein may not in any way become a nuisance by reason of
appearance, noise, dust, smoke, illumination, odor or any other similar factor.
11. An up-to-date Site Plan/Plan of Operation must be on file, at all times, with the Town of Eagle.
12. The Town reserve the right to review any condition imposed as part of the Conditional Use and/or Site
Plan/Plan of Operation if said use becomes a problem in the area. The Town Plan Commission may modify,
change, delete, add, etc. any conditions which they feel may be reasonable to allow this use and ensure it
does not become detrimental to the surrounding area.
13. Professional Fees. The petitioner shall, on demand, reimburse the Town of Eagle for all costs and expenses
of any type that the Town incurs in connection with this conditional use, including the cost of professional
services incurred by the Town (including engineering, legal, planning and other consulting fees) for the review
and preparation of required documents or attendance at meetings or other related professional services for
this application, as well as to enforce the conditions in this conditional ap proval due to a violation of these
conditions.
14. Payment of Charges. Any unpaid bills owed to the Town of Eagle by the subject property owner or his or her
tenants, operators or occupants, or agents, for reimbursement of professional fees (as described above);
or for personal property taxes; or for real property taxes; or for licenses, permit fees or any other fees owed
to the Town; shall be placed upon the tax roll for the Subject Property if not paid within 30 days of the billing
by the Town, pursuant to Section 66.0627, Wisconsin Statutes. Such unpaid bills also constitute a breach
of the requirements of this conditional approval that is subject to all remedies available to the Town,
including possible cause for termination of the conditional approval.
Jacob Heermans
Town Planner
Attachments
Exhibit A – Site Plan
Exhibit B – Building Plans
N:\PRKANDLU\Planning and Zoning\Community Assistance\T EAGLE\STAFF REPORTS AND PROJECTS\2025\2025-99 UPI SPPO CU\Staff Report UPI Manufacturing.docx
OWNER OWNER
DRETZKA INVESTMENTS LLC
C/O JEFF DRETZKA
W334S4375 CONNEMARA DR
DOUSMAN, WI 53118
P. (608) 846-4711
SEAL SEAL
I HEREBY CERTIFY THAT THIS PLAN SPECIFICATION OR REPORT WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED PROFESSIONAL ENGINEER UNDER THE LAWS
OF THE STATE OF WISCONSIN.
PROJECT AREA _______________________PROJECT AREA _______________________
FLOOR LEVELS _______________________FLOOR LEVELS _______________________
CONSTRUCTION CLASS _______________________CONSTRUCTION CLASS _______________________
SPRINKLER PROTECTION _______________________SPRINKLER PROTECTION _______________________
SUBMITTAL TYPE _______________________SUBMITTAL TYPE _______________________
PRIMARY OCCUPANCY TYPE _______________________PRIMARY OCCUPANCY TYPE _______________________
SECONDARY OCCUPANCY TYPE _______________________SECONDARY OCCUPANCY TYPE _______________________
OCCUPANCY SEPARATIONS _______________________OCCUPANCY SEPARATIONS _______________________
LOCATION PLAN
TOWN OF EAGLE
N/A
LOW HAZZARD FACTORY (F-2)
ADDITION 9,000 SQ. FT.
NONE
1
PROJECT LOCATIONLOCATION PLAN
WAUKESHA COUNTY, WI
PROJECT LOCATION
N/A
IIB
BUILDING DESIGN CRITERIABUILDING DESIGN CRITERIA
- CODE COMPLIANCE PER 2025 WISCONSIN- CODE COMPLIANCE PER 2025 WISCONSIN
COMMERCIAL BUILDING CODE (WCBC) (2021 IBC - CODES)
ENERGY COMPLIANCE PER IECC 2021
- BUILDING ENVELOPE REQUIREMENTS:- BUILDING ENVELOPE REQUIREMENTS:
CODE COMPLIANCE PER 2025 WISCONSIN
COMMERCIAL BUILDING CODE (WCBC) (2021 IBC - CODES)
CONDITIONED SPACE PER ASHRAE 90.1 (2019).
MTL BUILDING ROOF (U=0.035) SPS 363.0402
MTL BLDG WALL (U=0.050) SPS 363.0402
DOORS, SWINGING (U=0.37) SPS 363.0403
DOORS, NON SWINGING (U=0.31)
- PROVIDED THERMAL ENVELOPE:- PROVIDED THERMAL ENVELOPE:
MTL BUILDING ROOF R25+R11 LS, SSR (U=0.031)
MTL BUILDING WALL R30 (0.052) W/ THERMAL SPACER
BLOCKS
- OCCUPANCY TYPE- OCCUPANCY TYPE
F2 - FACTORY (METAL PARTS ASSEMBLY) = 23,000 SF
- CONSTRUCTION CLASSIFICATION - IIB- CONSTRUCTION CLASSIFICATION - IIB
METAL FRAME BUILDING
- BUILDING ALLOWABLE AREA- BUILDING ALLOWABLE AREA
- IBC 506.2 = 23,000 SF NON SPRINKLED
- FRONTAGE INCREASE = 75% * 23,000 SF = 17,250 SF
- OCCUPANT LOAD- OCCUPANT LOAD
FACTORY F-2 WITH 18 OCCUPANTS
ABBREVIATIONSABBREVIATIONS
BOC = BACK OF CURB
EOP = EDGE OF PAVEMENT
EOSW = EDGE OF SIDEWALK
TOF = TOP OF FOOTING
TOW = TOP OF WALL
FFE = FIRST FLOOR ELEVATION
SFE = SECOND FLOOR ELEVATION
ELEV. = ELEVATION
RO = ROUGH OPENING
BM = BENCHMARK
SQ. FT. = SQUARE FEET
DIA. = DIAMETER
TYP. = TYPICAL
HM = HOLLOW METAL
SS = STAINLESS STEEL
ALUM. = ALUMINUM
IBC = INTERNATIONAL BUILDING CODE
WD = WOOD
MTL. = METAL
STL. = STEEL
HSS = HOLLOW STEEL STRUCTURE
DF = DOUGLAS FIR
SPF = SPRUCE PINE FUR
SP = SOUTHERN PINE
CONC. = CONCRETE
WWF = WIRE WELDED FABRIC
OC = ON CENTER
EW = EACH WAY
EF = EACH FACE
WH = WATER HEATER
DW = DISHWASHER
REF. = REFRIGERATOR
FRZ. = FREEZER
FTG. = FOOTING
PC = PRECAST
OHD = OVERHEAD DOOR
T/O = TOP OF
GALV. = GALVANIZED
BRG. = BEARING
OH = OVERHANG
MFG. = MANUFACTURER
DIM. = DIMENSION
OFOI - OWNER FURNISHED OWNER INSTALLED
ARCHITECTURAL LEGENDARCHITECTURAL LEGEND
ANNOTATION CALLOUTS/DRAWING SYMBOLSANNOTATION CALLOUTS/DRAWING SYMBOLS
REVISION TAG
NORTH ARROW w/ TRUE NORTH
INDICATION
ROOM TAG
ELEVATION NUMBER
SECTION
EXTERIOR ELEVATION
ENLARGEMENT, DETAIL
SPOT ELEVATION
LEVEL NAME
SHEET NUMBER
SHEET NUMBER
SHEET NUMBER
SHEET KEYNOTE
INTERIOR ELEVATION
SHEET NUMBER
1
A201
A204
1
2
3
4
1
A301
1
A401
1
101
ROOM
100'
LEVEL 01
100'
A
PLAN NORTH
INDEX OF DRAWINGSINDEX OF DRAWINGS
NUMBERING SYSTEM:NUMBERING SYSTEM:
XX100 XX100
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICE
DISCIPLINE MODIFIER
REFER TO A/E/C CAD STANDARD FOR
SHEET NUMBERINGSTANDARDS
SHEET NUMBER WITHIN SERIES
DOOR TAG100A 100A
WINDOW TAGXX XX
WALL TAGXX XX
ROOM TAGXXXX XXXX
UNIT TAGXXXX XXXX
SMOKE TAGS S
FIRE EXTINGUISHER
- CABINET TYPE
FEC FEC
FIRE EXTINGUISHER
- CYLINDER TYPE
FE FE
FIRE EXTINGUISHER
& VALVE CABINET
FE+V FE+V
PULL STATIONF F
FIRE HORNH H
DOOR HOLD DEVICEDH DH
EXIT LIGHT
EXHAUST FAN
EMERGENCY LIGHT
RESCUE ASSISTANCE
INTERCOM
R R
RESCUE ASSISTANCE
DIRECTIONAL SIGN
R R
RESCUE ASSISTANCER R
BOULDER WALL
DRINKING FOUNTAINS
SIGN LOCATIONI I
FLOOR
ELEVATION
100'-0" FIN FLR.
NOTE:
ALL DIMENSIONS ARE STUD TO STUD
UNLESS OTHERWISE NOTED.
2025 BUILDING ADDITION2025 BUILDING ADDITION
UPI MANUFACTURINGUPI MANUFACTURING
S87W35670 GODFREY LNS87W35670 GODFREY LN
EAGLE, WI 53119EAGLE, WI 53119
NOVEMBER 25, 2025NOVEMBER 25, 2025
PROPOSED COMPLETED ELEVATION
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
G1.0 G1.0
0924-25
11/11/25
SSR TITLE SHEET2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
INDEX OF DRAWINGSINDEX OF DRAWINGS
SHEET NO. SHEET NO. DESCRIPTIONDESCRIPTION
GENERAL -
G1.0 TITLE SHEET
CIVIL -
C1.0 EXISTING PLAN
C2.0 PROPOSED SITE PLAN
C3.0 EROSION CONTROL PLAN
C4.0 EROSION CONTROL DETAILS
REVISIONS NO. DATE
INDEX OF DRAWINGSINDEX OF DRAWINGS
SHEET NO. SHEET NO. DESCRIPTIONDESCRIPTION
ARCHITECTURAL -
A-001 FIRST FLOOR ARCHITECTURAL CODE
A-100 FIRST FLOOR PLAN
A-200 REFLECTED CEILING PLAN
A-300 ROOF PLAN
A-400 EXTERIOR ELEVATIONS
A-500 BUILDING SECTIONS
A-600 WALL SECTIONS
A-610 DOOR & WINDOW SCHEDULES
STRUCTURAL -
S001 STRUCTURAL NOTES
S100 FOUNDATION PLAN
S110 BASE PLATE DETAILS
S111 FOUNDATION DETAILS
S200 ROOF FRAMING PLAN
MECHANICAL - DESIGN BUILT
PLUMBING - DESIGN BUILT
ELECTRICAL - DESIGN BUILT
12/2/25
935
940
936
937
938
939
935 936
937
939
936
937
935 935
930
930
930
935
935 935
940
940
940
LOT 1
4.16 AC±
UP
UP
UP
UP
GODFREY LN
PRICE LN
CHAPMAN LN
E4ISTING PLANSg·3½p¸·0
GODRE5 LN, EAGLE
3I p½11
UPI MANUACTURING
À0Àp UILDING ADDITION
\\ssr\res\Projects\2025\0924-25 UPI\CAD\SheetsPlan\C1.0.dwg
PARCEL: EGLT1818999042
DRETZKA INVESTMENTS LLC
W334S4375 CONNEMARA DR
DOUSMAN, WI 53118
PARCEL: EGLT1818999053
DRETZKA INVESTMENTS LLC
W334S4375 CONNEMARA DR
DOUSMAN, WI 53118
PARCEL: EGLT1818999056
DRR PROPERTIES LLC
S68W22800 NATIONAL AVE
BIG BEND, WI 53103-9641
PARCEL: EGLT1818999034
GODFREY LANE, LLC
W3128 STATE HWY 59
WHITEWATER, WI 53190-3035
PARCEL: EGLT1783994
STATION ROAD LLC
4 EARLING CT
OCONOMOWOC, WI 53066-4032
PARCEL: EGLT1817011
JOSEPH A SANFILIPPO AND LAURA L SANFILIPPO
S87W35575 EAGLE TER
EAGLE, WI 53119-2312
BENCHMARK TABLE
PARCEL: EGLT1818999028
EAGLE MARINE INVESTMENTS LLC
W357S8715 CHAPMAN LN
EAGLE, WI 53119-2312
PARCEL: EGLT1818999012
MJ SERVICES LLC
W356S8900 W GODFREY LN
EAGLE, WI 53119-2312
SITE DEVELOPMENT DATA:
SITE ADDRESS: S87W35670 GODFREY LN, EAGLE, WI
PARCEL ID 1818999053
LOT 1 CERT SURV 10963 VOL 107/49 REC IN DOC# 3909481 PT NW1/4 SEC 23
T5N R17E :: DOC# 3420791
LOT AREA: 5.433 AC±
CURRENT ZONING: B-4 MIXED BUSINESS
BLDG SETBACKS:
NORTH = 40'
SOUTH = 66'
EAST =100'
WEST = 98'
PROPOSED ADDITION: UFI MANUFACTURING FACILITY
EX. BUILDING FOOTPRINT = 59,850 SF (1.37± AC)
DRIVEWAY & PARKING = 106,786 SF (2.45± AC)
TOTAL IMPERVIOUS = 166,636 SF (3.83 AC) 70%
LANDSCAPE AREAS = 70,025 SF (1.60 AC) 30%
EXISTING PARKING STALLS = 55 STALLS / (3) ADA
570'
105'
131'
66'
98' 100'
PLOT SCALE :
PROJECT NO:
SHEET #
ILE NAME :
PLOT DATE :
PLOT 5 :
REVISIONS NO. DATE
ID DOCUMENTS SHEET NAME:PROJECT:
·p¸½ D±n¼b´´ RYt 3Ê
Vb±8, 3I p½p½ ¸0g~¸À0~½0½¸ OnnOb◦ ´Çb¼D±Á´´bÇbtbb±t.O
ROUSSEV
ENGINEERING
SOLUTIONS, LLC
ADDRESS:
½g0À IPP ST,
MADISON, 3I p½·1g
C1.0
0Às~Àp
11¹À·¹Àp
SSR
UP
UP
UP
UP
gg02 S
NEW
ADDITION
.
12x14 12x14
3070-G
3070-G
937
936
935
935
934
936
936935
938
938
939
GODFREY LN
PRICE LN
CHAPMAN LN
1
SITE DEVELOPMENT DATA:
SITE ADDRESS: S87W35670 GODFREY LN, EAGLE, WI
PARCEL ID 1818999053
LOT 1 CERT SURV 10963 VOL 107/49 REC IN DOC# 3909481 PT NW1/4 SEC 23
T5N R17E :: DOC# 3420791
LOT AREA: 5.433 AC±
CURRENT ZONING: B-4 MIXED BUSINESS
BLDG SETBACKS:
NORTH = 40'
SOUTH = 66'
EAST =100'
WEST = 98'
PROPOSED ADDITION: UFI MANUFACTURING FACILITY
EX. BUILDING FOOTPRINT = 68,885 SF (1.58± AC)
DRIVEWAY & PARKING = 97,751 SF (2.25± AC)
TOTAL IMPERVIOUS = 166,636 SF (3.83 AC) 70%
LANDSCAPE AREAS = 70,025 SF (1.60 AC) 30%
PROPOSED ADDITION = 9,000 SF (0.21± AC)
PROPOSED ADDITION REPLACES EXISTING PAVEMENT, THUS DOES NOT
INCREASE IMPERVIOUS AREA.
EXISTING PARKING STALLS = 55 STALLS / (3) ADA
40'
90'
105'
PARCEL: EGLT1818999053
DRETZKA INVESTMENTS LLC
W334S4375 CONNEMARA DR
DOUSMAN, WI 53118
100'
570'
66'
98'
201' 100'
SHEET KEYNOTES:
1. ALL EXISTING UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE
AND SHOULD BE FIELD VERIFIED PRIOR TO CONSTRUCTION.
PLAN KEY
1
PROPOSED ADDITION: FACTORY (F2) OCCUPANCY
9,000 SF
2
3
4
EX. ASPHALTIC PAVEMENT
ACCESSIBLE STALLS
LOADING DOCKS
269'
2
3
4 4
C2.0
02s~2p
¹2·¹2p
SSR PROPOSED SITE PLANSg·W½p¸·0
GODRE5 LN, EAGLE
WI p½
UPI MANUACTURING
202p UILDING ADDITION
PLOT SCALE :
PROJECT NO:
SHEET #
PLOT DATE :
PLOT 5 :
REVISIONS NO. DATE
ID DOCUMENTS SHEET NAME:PROJECT:
·p¸½ D±n¼b´´ RYt WÊ
Vb±8, WI p½p½ ¸0g~¸20~½0½¸ OnnOb◦ ´Çb¼D±Á´´bÇbtbb±t.O
ROUSSEV
ENGINEERING
SOLUTIONS, LLC
ADDRESS:
½g02 IPP ST,
MADISON, WI p½·g
\\ssr\res\Projects\2025\0924-25 UPI\CAD\SheetsPlan\C2.0.dwgILE NAME :
UP
UPUP UP
gg0À SNEWADDITION
12x14 12x14
3070-G
3070-G
937
936935
935934936936935
938938939
GODFREY LNPRICE LNCHAPMAN LN66'
98'
C3.00Às~ÀpÀ¹À¹ÀpSSR EROSION CONTROL PLANSg·W3p¸·0GODRE5 LN, EAGLEWI p3UPI MANUACTURINGÀ0Àp UILDING ADDITION
PLOT SCALE :PROJECT NO:SHEET #PLOT DATE :PLOT 5 : REVISIONSNO.DATE
ID DOCUMENTSSHEET NAME:PROJECT:·p¸3 D±n¼b´´ RYt WÊVb±8, WI p3p3¸0g~¸À0~303¸ OnnOb◦ ´Çb¼D±Á´´bÇbtbb±t.OROUSSEVENGINEERINGSOLUTIONS, LLCADDRESS:
3g0À IPP ST,MADISON, WI p3·g
\\ssr\res\Projects\2025\0924-25 UPI\CAD\SheetsPlan\C3.0.dwgILE NAME :
EROSION CONTROL KEYTRACKING PADCLASS II RIP-RAP @ STORM SEWER OUTLET, TYP.SILT FENCE, TYP.INLET PROTECTION, TYP.IP
EROSION CONTROL NOTES:1.THE CONTRACTOR SHALL IMPLEMENT AND MAINTAIN EROSIONCONTROL DEVICES FROM THE START OF LAND DISTURBING CONSTRUCTION ACTIVITIES UNTIL FINAL STABILIZATION OF THE CONSTRUCTION SITE.2.ALL EROSION CONTROL MEASURES SHALL BE INSTALLED IN ACCORDANCE WITH TOWN EROSION CONTROL ANDSTORMWATER ORDINANCE AND THE APPROPRIATE WISCONSINDNR CONSTRUCTION SITE EROSION AND SEDIMENT CONTROLTECHNICAL STANDARDS. THE TOWN RESERVES THE RIGHT TOREQUIRE ADDITIONAL EROSION CONTROL MEASURES ASCONDITIONS WARRANT.3.CLEANING RIGHT-OF-WAY SURFACES SHALL BE THOROUGHLYCLEANED BEFORE THE END OF EACH WORKING DAY WITHOUTHYDRAULIC FLUSHING.4.RESTORATION RESTORATION SHALL BE COMPLETED AS NOTED INTHE CONSTRUCTION SCHEDULE UNLESS OTHERWISE AUTHORIZED BYTHE TOWN.5.INSPECTION THE CONTRACTOR SHALL INSPECT EROSION ANDSEDIMENT CONTROL PRACTICES WEEKLY, AND WITHIN 24 HOURSFOLLOWING A RAINFALL OF 0.5 INCHES OR GREATER.DOCUMENTATION OF EACH INSPECTION SHALL INCLUDE THETIME, DATE AND LOCATION OF INSPECTION, THE PHASE OF LANDDISTURBANCE AT THE CONSTRUCTION SITE, PERSON CONDUCTING THE INSPECTION, ASSESSMENT OF CONTROL PRACTICES, AND A DESCRIPTION OF ANY EROSION OR SEDIMENTCONTROL MEASURE INSTALLATION.6.STONE TRACKING PAD. BEFORE BEGINNING CONSTRUCTION,CONTRACTOR SHALL INSTALL A STONE TRACKING PAD AT EACHPOINT WHERE VEHICLES ENTERS/EXITS THE CONSTRUCTION SITE.STONE TRACKING PADS SHOULD BE AT LEAST 24 FEET WIDE AND 50FEET LONG, AND CONSTRUCTED OF 3-6 INCH WASHED STONE WITHA DEPTH OF AT LEAST 12 INCHES. ON SITES WITH CLAY SOILS, TONETRACKING PADS MUST BE UNDERLAIN WITH A GEOTEXTILE LINER TOPREVENT THE STONE FROM SINKING INTO THE SOIL.7.INLET PROTECTION. ALL INLETS SUBJECT TO DRAINAGE SHALL BEPROTECTED WITH TYPE D INLET PROTECTION OR APPROVED EQUAL.ANY DEPOSITS OF DIRT, MUD, ROCK, DEBRIS, OR OTHER MATERIALENTERING THE STORM SEWER SYSTEM SHALL BE PROMPTLY ANDTHOROUGHLY CLEANED OUT.8.EROSION MAT. AREAS OR EMBANKMENTS HAVING SLOPESGREATER THAN OR EQUAL TO 4H:1V SHALL BE STABILIZED WITHWISCONSIN DOT CLASS 1, URBAN, TYPE B, EROSION MAT.9.TEMPORARY EROSION CONTROL. ALL TEMPORARY EROSION ANDSEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30DAYS AFTER FINAL SITE STABILIZATION IS ACHIEVED OR AFTER THETEMPORARY MEASURES ARE NO LONGER NEEDED.10.STABILIZATION. STABILIZE AREAS OF FINAL GRADING WITHIN 7 DAYSOF REACHING FINAL GRADE.11.TOPSOIL. A MINIMUM OF 4 INCHES OF TOPSOIL MUST BE APPLIEDTO ALL AREAS TO BE SEEDED OR SODDED.12.SEEDING. SEED MIXTURE SHALL BE APPLIED AT A RATE OF 2 LBS PER1,000 SF OF AREA OR AS NOTED ON THE LANDSCAPE PLAN.13.STOCKPILES. IMMEDIATELY STABILIZE STOCKPILES AND SURROUNDSTOCKPILES AS NEEDED WITH SILT FENCE OR OTHER PERIMETERCONTROL IF STOCKPILES WILL REMAIN INACTIVE FOR 7 DAYS ORLONGER.14.DEWATERING SHALL FOLLOW DNR TECHNICAL STANDARD 1061.15.CONCRETE WASHOUT AREA SHALL BE DESIGNATED BMP PER DNRTECHNICAL STANDARD.
EROSION MATTEMPORARY DITCH CHECK, TYP.
TRACKING PAD, TYP.SILT FENCE OR EROSION SOCK, TYP.
3'MAX3'MAX3'MAX3'MAXFOLD3" MAX.SUPPORT CORDGEOTEXTILE FABRICFLOW2'± 2WOOD POSTLENGTH 4' MIN.2' MIN. DEPTH INGROUND
1FLOWDIRECTIONGEOTEXTILE FABRIC ONLYBACKFILL AND COMPACT TRENCHWITH EXCAVATED SOIL*
ATTACH THE FABRIC TO THEPOST w/WIRE STAPLES ORWOODEN LATH AND NAILS
SILT FENCE TIE BACK DETAILANCHOR STAKEMIN. 18" LONGTIE BACK BETWEENFENCE POSTAND ANCHORFLOW DIRECTIONGEOTEXTILE FABRICEXCESSFABRICTRENCH DETAILWOODPOST1321 NOTES:TRENCH SHALL BE A MINIMUM OF 4" WIDE BY 6" DEEP TO BURY AND ANCHOR THE GEOTEXTILE FABRIC, FOLD MATERIALTO FIT TRENCH AND BACKFILL AND COMPACT TRENCH WITH EXCAVATED SOIL.HORIZONTAL BRACE WITH 2" X 4" WOODEN FRAME OR EQUIVALENT AT TOP OF POST AS DIRECTED BY THE ENGINEER. WOOD POST SHALL BE A MINIMUM SIZE OF 1 1/8" X 1 1/8" OF OAK OR HICKORY.NOTE:8' POST SPACING ALLOWED IF AWOVEN GEOTEXTILE FABRIC IS USED.*
GEOTEXTILE FABRICWOOD POSTGEOTEXTILE FABRICGEOTEXTILE FABRICFLOW DIRECTION
GEOTEXTILE FABRICWOOD POSTJOINING LENGTHS OF SILT FENCE3'5:15:1
NOTE:MAINTAIN THE ROCK ENTRANCE TOPREVENT TRACKING ONTO PAVEMENT
3" CLEAR STONEMIN. 12" THICKGEOTEXTILE MATERIAL6" HIGH BERMEXISTINGPAVEMENTSECTION A-A1.FOLLOW WISCONSIN DNR TECHNICAL STANDARD 1057 FOR FURTHER DETAILS AND INSTALLATION.2.LENGTH - MINIMUM OF 50'.3.WIDTH - 24' MINIMUM, SHOULD BE FLARED AT THE EXISTING ROAD TO PROVIDE A TURNING RADIUS.4.ON SITES 'MTH A HIGH GROUND WATER TABLE OR WHERE SATURATED CONDITIONS EXIST, GEOTEXTILE FABRIC SHALL BE PLACEDOVER EXISTING GROUND PRIOR TO PLACING STONE. FABRIC SHALL BE WISDOT TYPE-HR GEOTEXTILE FABRIC.5.STONE - CRUSHED 3" CLEAR STONE SHALL BE PLACED AT LEAST 12" DEEP OVER THE ENTIRE LENGTH AND WIDTH OF ENTRANCE.6.SURFACE WATER - ALL SURFACE WATER FLOWING TO OR DIVERTED TOWARDS CONSTRUCTION ENTRANCES SHALL BE PIPEDTHROUGH THE ENTRANCE. MAINTAINING POSITIVE DRAINAGE. PIPE INSTALLED THROUGH THE STABILIZED CONSTRUCTION ENTRANCESHALL BE PROTECTED WITH A MOUNTABLE BERM WITH 5:1 SLOPES AND MINIMUM OF 6" STONE OVER THE PIPE. PIPE SHALL BE SIZEDACCORDING TO THE DRAINAGE REQUIREMENTS. WHEN THE ENTRANCE IS LOCATED AT A HIGH SPOT AND HAS NO DRAINAGE TOCONVEY A PIPE SHALL NOT BE NECESSARY. THE MINIMUM PIPE DIAMETER SHALL BE 6". CONTRACTOR SHALL BE RESPONSIBLE FORTHE MAINTENANCE OF SAID PIPE.7.LOCATION - A STABILIZED CONSTRUCTION ENTRANCE SHALL BE LOCATED WHERE CONSTRUCTION TRAFFIC ENTERS AND/OR LEAVESTHE CONSTRUCTION SITE. VEHICLES LEAVING THE SITE MUST TRAVEL OVER THE ENTIRE LENGTH OF THE TRACKING PAD.
50' MIN.
24'TYP.10'TYP.10'TYP.
A
A
1-SILT FENCE
2-TRACKING PAD
EXISTING GROUND
SEDIMENT CONTROLLED LOGMIN. 24" OVERLAPSTAKE
12"1' 1'FLOWSEDIMENTCONTROLLED LOGRECPAPRONSTAKE ATCENTER OF LOG
EXISTING GROUND3-TEMPORARY DITCH CHECK
OVERLAP LOGSMIN. 24"TIGHT, NO GAPS
FLOW
SEDIMENTCONTROLLED LOG
DITCH CHECKS
\\ssr\res\Projects\2025\0924-25 UPI\CAD\SheetsPlan\C5.0.dwgFILE NAME :FILE NAME :\\ssr\res\Projects\2025\0924-25 UPI\CAD\SheetsPlan\C5.0.dwgC4.00À4~ÀpÀ¹À¹ÀpSSR EROSION CONTROLDETAILSSg·3½p¸·0GODRE5 LN, EAGLE3I p½UPI MANUACTURINGÀ0Àp UILDING ADDITION
PLOT SCALE :PROJECT NO:SHEET #PLOT DATE :PLOT 5 : REVISIONSNO.DATE
ID DOCUMENTSSHEET NAME:PROJECT:·p¸½ D±n¼b´´ RYt 3ÊVb±8, 3I p½p½¸0g~¸À0~½0½¸ OnnOb◦ ´Çb¼D±Á´´bÇbtbb±t.OROUSSEVENGINEERINGSOLUTIONS, LLCADDRESS:
½g0À IPP ST,MADISON, 3I p½·g
BUILDING CODE REVIEWBUILDING CODE REVIEW
REFERENCED CODES INTERNATIONAL BUILDING CODE (IBC) - 2021
BUILDING CLASSIFICATION MAJOR OCCUPANCY: LOW HAZARD FACTORY, GROUP F-2
METAL PRODUCTS (FABRICATION AND ASSEMBLY)
CONSTRUCTION TYPE IIB
FIRE PROTECTION SYSTEMS SPRINKLED: BLDG NOT EQUIPPED W/ AN AUTOMATIC SPRINKLER SYSTEM
BUILDING HEIGHT AND AREA
LIMITATIONS
ALLOWABLE AREA - IBC 506.2 (F-2) NS = 23,000 SF
1 STORY
SECONDARY OCCUPANCY: N/A
FIRE AREA 2FIRE AREA 2 + NEW ADDITION+ NEW ADDITION
BUILDING PERIMETER WITH 30'+ OPEN SPACE = 634'
TOTAL BUILDING PERIMETER (FIRE AREA 2) = 844'
PERCENTAGE OF BUILDING PERIMETER WITH 30' OPEN SPACE =634/844 =75%
AMOUNT OF INCREASE PER IBC 506.3.3 = 0.75, OR 75%*23,000 = 17,250 SF
FRONTAGE INCREASE
TOTAL ALLOWABLE AREA = 23,000 SF + 17,250 = 40,250 SF
GROSS BUILDING AREA FIRE AREA 1 = 23,543 SF < 40,250 SF
FIRE AREA 2 = 32,323 SF < 40,250 SF
FIRE AREA 3 = 11,811 SF < 26,000 SF
BUILDING FIRE AREA - IBC 903: NO LIMITS ON FIRE AREA FOR F-2 OCCUPANCY
BUILDING CODE REVIEWBUILDING CODE REVIEW
MEANS OF EGRESS - CHAPTER 10
OCCUPANT LOAD
IBC 1005.3.2 (1): EGRESS WIDTH - 0.15 " PER OCCUPANT 18 X 0.15" = 4.35"
TOTAL EXISTING EGRESS WIDTH
PLUMBING FIXTURES FOR CURRENT CONSTRUCTION
EGRESS OPENINGS (2) SERVICE DOOR @ 36"
72" : OK
SECTION 2902 - MINIMUM PLUMBING FACILITIES
PLUMBING FIXTURE CALCULATIONS:
F2/ MALE F2 / FEMALE
WATER CLOSETS 14/100=0.14 14/100=0.14
LAVATORIES 14/100=0.14 14/100=0.14
TOTAL MENS = 0.14 (1 REQUIRED), PROVIDED BY EXISTING FACILITY
TOTAL WOMENS =0.14 (1 REQUIRED), PROVIDED BY EXISITNG FACILITY
TOTAL LAVATORIES =0.14 (1 REQUIRED), PROVIDED BY EXISTING FACILITY
TOTAL DRINKING FOUNTAINS =1/400 (1REQUIRED), PROVIDED BY EXISTING FACILITY
TOTAL SERVICE SINKS =1 REQUIRED, PROVIDED BY EXISTING FACILITY
18 OCCUPANTS
IBC 1029.7 TRAVEL DISTANCE
- EXIT ACCESS TRAVEL DISTANCE: MAX ALLOWED PER TABLE 1017.2 = 300' - 0" FOR BLDG W/O SPRINKLER SYSTEM FOR LOW
HAZARD FACTORY (F-2) OCCUPANCY < 300' - 0"
EXIT LIGHT
FIRE EXTINGUISHER
-CYLINDER TYPE
FE FECFIRE EXTINGUISHER
-CABINET TYPE
FEC FIRE EXTINGUISHER
-CABINET TYPE
A-400 A-4001 1A-400 A-4002 2
DD
CC
BB
AA
1 2 3 4 5
23543 SF 23543 SF
FIRE AREA 1FIRE AREA 1
32323 SF 32323 SF
FIRE AREA 2FIRE AREA 2
11811 SF 11811 SF
FIRE AREA 3FIRE AREA 3
114' - 10" 113' - 2" 113' - 0" 114' - 0" 115' - 0"
NEW NEW
ADDITION ADDITION
3-HR FIRE WALL
3-HR FIRE WALL
3-HR FIRE WALL
3-HR FIRE WALL
105' - 0"
40' - 8" 100' - 0" 86' - 4" 115' - 0"
90' - 0"
105' - 0"
228' - 0"
F-2 / B F-2 / B F-2 F-2F-2 / B F-2 / B S-2 S-2
F-2 F-2
64'
30'60'
64'
85'3'
4' 4'
FE FE
9'
EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING
PLAN NORTH
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
A-001 A-001
0924-25
11/11/25
SSR FIRST FLOOR
ARCHITECTURAL CODE
2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
ROOM OCCUPANCYROOM OCCUPANCY
ROOM ROOM
NO NO NAME NAME AREA AREA
FUNCTION OFFUNCTION OF
SPACE SPACE
OCCUPANTOCCUPANT
LOAD LOAD
FACTOR FACTOR
OCCUPANTOCCUPANT
LOAD LOAD COMMENTSCOMMENTS
1 NEW ADDITION 8802 SF FACTORY F-2 500 18
TOTAL: 1 18
10' 20' 40'0
2"0
1" = 20'-0"
SCALE: 1'-0" = 40' on 11" x 17"
1'-0" = 20' on 22" x 34"
FIRST FLR. FIRST FLR.
1 1
REVISIONS NO. DATE
A-400 A-4002 2
A-500 A-5001 1
D
D
CC
BB
AA
1 2 3 4 5
100
103 102
101
12' - 0" 30' - 0" 30' - 0" 28' - 0"
1' - 0" 1' - 0"
100' - 0"
30' - 0" 30' - 0" 30' - 0"
90' - 0"
8802 SF
1
NEW NEW
ADDITION ADDITION
FACTORY F-2
EXISITNG WALL 16x14
3070-G 16x14
3070-G
12' - 0"
2 2
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
1/8" = 1'-0"
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
A-100 A-100
0924-25
11/11/25
SSR FIRST FLOOR PLAN2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
SCALE: 1/16" = 1'-0" on 11" x 17"
1/8" = 1'-0" on 22" x 34"
FIRST FLOOR PLANFIRST FLOOR PLAN
1 1
4' 8' 16'0
2"0
1/8" = 1'-0"
PLAN NORTH
REVISIONS NO. DATE
DD
CC
BB
AA
1 2 3 4 5
OPEN TO ROOF STRUCTUREOPEN TO ROOF STRUCTURE
EXISTING BUILDINGEXISTING BUILDING
3-HR FIRE WALL
CEILING LEGENDCEILING LEGEND
24" X 24" ACOUSTICAL CEILING TILE
GYPSUM WALL BOARD / PAINT
EXPOSED CEILING TO ROOF DECK
FLUORESCENT STRIP FIXTURE
RECESSED FLUORESCENT FIXTURE
LIGHTING FIXTURES ON EMERGENCY POWER SOURCE
SUPPLY FRESH AIR
RETURN AIR REGISTER
CEILING MOUNTED OCCUPANCY SENSOR
CARBON MONOXIDE DETECTORS
EXIT LIGHT FIXTURESPRINKLER HEAD
EXIT LIGHT FIXTURE
CMD
SCALE: 1/16" = 1'-0" on 11" x 17"
1/8" = 1'-0" on 22" x 34"
FIRST FLR. REFLECTED CEILING PLANFIRST FLR. REFLECTED CEILING PLAN
1 1
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
1/8" = 1'-0"
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
A-200 A-200
0924-25
11/11/25
SSR REFLECTED CEILING
PLAN
2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
REVISIONS NO. DATE
A-400 A-4002 2
A-500 A-5001 1
DD
3 3
A-300 A-300
Sim Sim
______________________ 3 3
A-300 A-300
Sim Sim
______________________
CC
BB
AA
1 2 3 4 5
4 4
A-300 A-300
Sim Sim
______________________
EXISTING ROOFEXISTING ROOF
NEW ROOF NEW ROOF
100' - 0"
90' - 0"
3/8" / 12" 3/8" / 12" 3/8" / 12" 3/8" / 12"
2 2
THERMAL SPACER BLOCK
PANEL CLIP
STANDING SEAM ROOF PANEL
UNFACED FG INSULATION
2ND LAYER (R11)
UNFACED FG INSULATION
1ST LAYER (R25)
MTL JOIST OR PURLINS STEEL BANDING
LONGITUDINAL AND TRANSVERSE
MEMBRANE & VAPOR RETARDER
(CONCEALS PURLIN)
R25+R11 LINER SYSTEM ON METAL ROOF
U=0.031 PER ASHRAE 90.1, TABLE A2.3.3
OUTSIDE CLOSURE PANEL RIB
1/8" X 1" TAPE MASTIC
12-14 X 1 1/4" SSR STRUT FSNR 6" O.C.
FACE OF WALL PANEL
RAKE FASCIA
9-IN TYP.
1/4 - 14 x 7/8"
WALL STITCH FSNR
1'-0" O.C.
RAKE FASCIA RETAINER
WALL PANEL
PANEL CLOSURE ANGLE
1/4-14 X 7/8" WALL STITCH FNSR 1'-0" O.C.
OUTSIDE CLOSURE PANEL RIB
W.P.
FACE OF WALL PANEL
SSR CLOSURE PLUG (2'-0") O.C.
EAVE GUTTER STRAP
1/4-14 X 7/8" S.S. ROOF STITCH FASTNER
STRAP
1/8" X 1" TAPE MASTIC AND OVER PLUG
EAVE GUTTER
1/4-14 X 7/8
S.S. ROOF STITCH
FASTENER 5 PER PANEL
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
A-300 A-300
0924-25
11/11/25
SSR ROOF PLAN2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
SCALE: 1/16" = 1'-0" on 11" x 17"
1/8" = 1'-0" on 22" x 34"
ROOF FLOOR PLANROOF FLOOR PLAN
1 1
PLAN NORTH
NOT TO SCALE
ROOF SECTIONROOF SECTION2 2 NOT TO SCALE
ROOF SSR RAKE TRIMROOF SSR RAKE TRIM3 3 NOT TO SCALE
ROOF SSR W/ EAVE GUTTERROOF SSR W/ EAVE GUTTER4 4
4' 8' 16'0
2"0
1/8" = 1'-0"
REVISIONS NO. DATE
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
ROOF LE EXROOF LE EX
124' - 0" 124' - 0"
24 GA TRIPLE LOCK STANDING SEAM ROOF
MACHINE SEAM OVER "Z" PURLINS W/
SIMPLE SAVER SYSTEM INSULATION
D
ROOF HE EXROOF HE EX
127' - 3 3/8"127' - 3 3/8"
1
C B A
ROOF LE ROOF LE
123' - 5 13/16"123' - 5 13/16"
3/8" / 12" 3/8" / 12"
90' - 0"
2
3
3070-G
12x14
3/8" / 12" 3/8" / 12"
EXISTING BUILDINGEXISTING BUILDING
126' - 3 1/2"
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
24 GA TRIPLE LOCK STANDING SEAM ROOF
MACHINE SEAM OVER "Z" PURLINS W/
SIMPLE SAVER SYSTEM INSULATION
ROOF HE EXROOF HE EX
127' - 3 3/8"127' - 3 3/8"
1
12345
ROOF LE ROOF LE
123' - 5 13/16"123' - 5 13/16"
28' - 0" 30' - 0" 30' - 0" 12' - 0"
2
3
EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDING
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
24 GA TRIPLE LOCK STANDING SEAM ROOF
MACHINE SEAM OVER "Z" PURLINS W/
SIMPLE SAVER SYSTEM INSULATION
D
ROOF HE EXROOF HE EX
127' - 3 3/8"127' - 3 3/8"
CBA
ROOF LE ROOF LE
123' - 5 13/16"123' - 5 13/16"
ROOF LE ROOF LE
123' - 5 13/16"123' - 5 13/16"
3/8" / 12" 3/8" / 12"
1
12x14
3070-G
3/8" / 12" 3/8" / 12"
EXISTING BUILDINGEXISTING BUILDING
126' - 3 1/2"
SCALE: 1/8" = 1'-0" on 11" x 17"
1/4" = 1'-0" on 22" x 34"
EAST ELEVATIONEAST ELEVATION
1 1
SCALE: 1/16" = 1'-0" on 11" x 17"
1/8" = 1'-0" on 22" x 34"
NORTH ELEVATIONNORTH ELEVATION
3 3
ELEVATION NOTESELEVATION NOTES
Item Description
1 STEEL - PANEL RIB - AMERICAN BUILDING SURREY BEIGE
2 6"X6" GUTTER: COLOR AMERICAN BUILDINGS -MIDNIGHT BLACK
3 5"X6" DOWNSPOUT: COLOR AMERICAN BUILDINGS -MIDNIGHT BLACK
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
1/8" = 1'-0"
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
A-400 A-400
0924-25
11/11/25
SSR EXTERIOR ELEVATIONS2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
SCALE: 1/16" = 1'-0" on 11" x 17"
1/8" = 1'-0" on 22" x 34"
WEST ELEVATIONWEST ELEVATION
2 2
4' 8' 16'0
2"0
1/8" = 1'-0"
REVISIONS NO. DATE
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
T.O. FTG. T.O. FTG.
96' - 0" 96' - 0"
B.O. FTG B.O. FTG
95' - 0" 95' - 0"
D
ROOF HE EXROOF HE EX
127' - 3 3/8"127' - 3 3/8"
C B A
ROOF LE ROOF LE
123' - 5 13/16"123' - 5 13/16"
6" CONCRETE SLAB
W.W.F 6x6-8X8 (W2.1XW2.1)
6 MIL VAPOR BARRIER, &
8" COMPACTED GRANULAR FILL
3 3
S100 S100
Sim Sim
______________________
12x14
3070-G
EXISTING BUILDINGEXISTING BUILDING
3/8" / 12" 3/8" / 12"
3/8" / 12" 3/8" / 12"
PROPOSED ADDITIONPROPOSED ADDITION
A-600 A-600
1 1
30' - 0" 30' - 0" 30' - 0"
90' - 0"
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
T.O. FTG. T.O. FTG.
96' - 0" 96' - 0"
B.O. FTG B.O. FTG
95' - 0" 95' - 0"
1 2 3 4 5
ROOF LE ROOF LE
123' - 5 13/16"123' - 5 13/16"
28' - 0"30' - 0"30' - 0"12' - 0"
100' - 0"
S100 S100
3 3 Sim Sim
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
3/16" = 1'-0"
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
A-500 A-500
0924-25
11/11/25
SSR BUILDING SECTIONS2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
SCALE: 3/32" = 1'-0" on 11" x 17"
3/16" = 1'-0" on 22" x 34"
BLDG SECTION ABLDG SECTION A
1 1
2.7' 5.3' 10.7'0
2"0
3/16" = 1'-0"
SCALE: 3/32" = 1'-0" on 11" x 17"
3/16" = 1'-0" on 22" x 34"
BLDG SECTION BBLDG SECTION B
2 2
REVISIONS NO. DATE
METAL WALL PANEL (EXTERIOR)
1/8" FOAM TAPE OR BREAK STRIP
GIRT, PER PEMB
R30 FACED ON UNFACED FG INSULATION IN CAVITY (SINGLE LAYER)
W/ THERMAL BLOCK
U=0.052 ASHRAE 90.1-2013 (b) TABLE A3.2.3
VERTICAL METAL BANDING
MEMBRANE OR FACING
INSTALLED SEPARATELY OR
ADHERED TO INSULATION
INTERIOR EXTERIOR
R30, SINGLE LAYER FG INSULATION IN CAVITY
U=0.052, PER ASHRAE 90.1, TABLE A3.2.3 (b)
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
T.O. FTG. T.O. FTG.
96' - 0" 96' - 0"
B.O. FTG B.O. FTG
95' - 0" 95' - 0"
A
ROOF LE ROOF LE
123' - 5 13/16"123' - 5 13/16"3' - 11 7/8"6' - 0"6' - 1 1/4"7' - 3 1/4"
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
A-600 A-600
0924-25
11/11/25
SSR WALL SECTIONS2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
NOT TO SCALE
EXTERIOR WALL SECTIONEXTERIOR WALL SECTION2 2 SCALE: 1/4" = 1'-0" on 11" x 17"
1/2" = 1'-0" on 22" x 34"
WALL DETAILWALL DETAIL
1 1
REVISIONS NO. DATE
F FLUSH
P PAIR DOOR
L LOUVER (BOTTOM)
TL LOUVER (TOP)
LL LOVER (TOP AND BOTTOM)
V VISION LITE
VL VISION LITE AND LOUVER
N NARROW LITE
NL NARROW LITE AND LOUVER
G HALF GLASS
GL HALF GLASS AND LOUVER
FG FULL GLASS
FL FULL LOUVER
D DUTCH DOOR
OHD OVERHEAD SECTIONAL DOOR
OHC OVERHEAD COILING DOOR
LEGEND - DOOR TYPESLEGEND - DOOR TYPES
1. ALL DOORS SHALL HAVE A MINIMUM STC
RATING OF 35 UNLESS NOTED OTHERWISE.
2. ALL EXTERIOR DOORS NOT LOCATED IN
STOREFRONT / CURTAINWALL ASSEMBLIES SHALL
BE INSULATED HOLLOW METAL AND MINIMUM
LEVEL 2 PERFORMANCE LEVEL B PER SDI/DOOR
A250.8. ALL DOOR FRAMES SHALL BE WELDED.
DOOR FRAMES SHALL BE FILLED WITH SPRAY
FOAM INSULATION. EXTERIOR DOORS SHALL
EXCEED MINIMUM INSULATION REQUIRED IN A
SHRAE 90.1 - IP.
3. INTERIOR VESTIBULE DOORS SHALL MATCH THE
TYPE, CONSTRUCTION AND CONFIGURATION OF
THEIR CORRESPONDING EXTERIOR DOORS.
4. INTERIOR DOORS SHALL BE SOLID CORE WOOD
VENEER DOOR. FRAMES SHALL BE WELDED
HOLLOW METAL. HM DOORS AND FRAMES
SHALL RECEIVE A PAINTED FINISH.
5. LOCKSETS MUST ACCEPT MARSHALL BEST 6-PIN
REMOVABLE CORE.
6. THERMALLY BROKEN FRAME
7. INSULATED DOOR
8. TRACK & HARDWARE BY MANUFACTURER
9. UL RATED DOOR & FRAME ASSEMBLY
10. UNDERCUT DOOR 1"
11. PROVIDE ALL EXTERIOR EGRESS DOORS WITH
PANIC HARDWARE OR FIRE EXIT HARDWARE PER
IBC. 1010.1.10. MAIN EXIT DOORS ARE PERMITED
TO BE LOCKING PER IBC 1010.1.9.3
GENERAL NOTES - DOORSGENERAL NOTES - DOORS
ALUM ALUMINUM
HM HOLLOW METAL
MTL METAL
PNT PAINTED
INS INSULATED
ANOD ANNODIZED
FRP FIBRE REINFORCED POLYMER
WD WOOD SOLID CORE
DOOR ABBREVIATIONSDOOR ABBREVIATIONS
GL-1 EXTERIOR INSULATED GLAZING UNIT
GL-2 FIRE RATED GLASS (D-H-60 OR D-H-W-60)
GL-3 TEMPERED SAFETY GLASS
GLAZING SCHEDULEGLAZING SCHEDULE
OHD-1 OHD-1
14' - 0"
12' - 0"
F F N N
4 5/8"
FG FG
6" 6"
10"
DOOR TYPES:DOOR TYPES:
4' - 7 3/8" 2' - 0"
6"
7' - 0"
FINISHED FLOOR
6"
3' - 0" 3' - 0" 3' - 0"
6" 6"
6"
3' - 0"
G G P P
7' - 0"
6' - 0"
F1 F1
FRAME TYPES:FRAME TYPES:
2"
SEE SCHED
2"
SEE SCHED 2"
F2 F2
2" SEE SCHED 2"
SEE SCHED 2"
GL-1 EXTERIOR INSULATED & TEMPERED GLAZING UNIT
GL-2 FIRE RATED GLASS (D-H-60 OR D-H-W-60)
GL-3 TEMPERED SAFETY GLASS
GLAZING SCHEDULEGLAZING SCHEDULE
TYPE
SEE FRAME
DOOR HEIGHT
SEE SCHED
HM FRAME SEE SCHEDULE
PROVIDE DOOR SILENCERS, TYP.
DOOR (SEE SCHEDULE)
SEALENT
METAL WALL PANEL (EXTERIOR)
GIRT WALL BY PEMB
R30 FACED ON UNFACED FG INSULATION
IN CAVITY (SINGLE LAYER)
W/ THERMAL BLOCK
U=0.052 ASHRAE 90.1-2013 (b) TABLE
A3.2.3
METAL FLASHING
EXTERIOR EXTERIOR
WINDOW MTL STUD FRAMING
2"
TYPE
SEE FRAME
DOOR WIDTH
SEE SCHED
CONTINUOUS CAUKING
(TYPICAL ALL DOOR FRAMES)
HM FRAME SEE SCHEDULE
SEALENT
JAMB ANCHORS, 3 PER SIDE
RETAINER COVER
EXTERIOR EXTERIORINTERIOR INTERIOR
CONTINUOUS CAUKING
(TYPICAL ALL DOOR FRAMES)
METAL WALL PANEL (EXTERIOR)
GIRT WALL BY PEMB
R30 FACED ON UNFACED FG INSULATION IN
CAVITY (SINGLE LAYER)
W/ THERMAL BLOCK
U=0.052 ASHRAE 90.1-2013 (b) TABLE A3.2.3
P.T. FURRING STRIP
MTL STUD STOREFRONT FRAMING
COMPRESSABLE FILLER WITH
BACKER ROD AND
SEALANT
HOLLOW METAL FRAME
ALUMINUM THRESHOLD,
GROUT FILLED SET IN BED
OF SEALANT
CONCRETE FLOOR SLAB,
SEE STRUCTURAL
EXPANSION ANCHORS
CONCRETE
APRON, SEE CIVIL
DOOR AS SCHEDULED, GASKET
OR SEAL FOR EXT. CONDITION
EXTERIOR EXTERIORINTERIOR INTERIOR
P.T. 2x WOOD BLOCKING
2" RIGID INSULATION
4"
6"
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
A-610 A-610
0924-25
11/11/25
SSR DOOR & WINDOW
SCHEDULES
2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
DOOR SCHEDULEDOOR SCHEDULE
Mark Mark
SIZE SIZE DOOR DOOR FRAME FRAME
GLZ GLZ NOTES NOTESW W HT HT THK THK ELEV ELEV MAT'L MAT'L ELEV ELEV MAT'L MAT'L
100 3' - 0" 7' - 0" 1 3/4" G HM F2 HM GL-1
101 3' - 0" 7' - 0" 1 3/4" G HM G2 HM GL-1
102 12' - 0" 14' - 0" 1 3/4" OVERHEAD DOOR
103 12' - 0" 14' - 0" 1 3/4" OVERHEAD DOOR
Grand total: 4
NOT TO SCALE
HM EXTERIOR DOOR HEADHM EXTERIOR DOOR HEAD2 2
NOT TO SCALE
HM EXTERIOR DOOR JAMBHM EXTERIOR DOOR JAMB1 1
NOT TO SCALE
HM EXTERIOR DOOR SILLHM EXTERIOR DOOR SILL3 3
REVISIONS NO. DATE
STRUCTURAL DESIGN DATA:STRUCTURAL DESIGN DATA:
DESIGN CODE:DESIGN CODE:
2025 WISCONSIN ENROLLED COMMERCIAL BUILDING CODE (2021 IBC)
SOIL LOAD:SOIL LOAD:
ALLOWABLE NET SOIL BEARING PRESSURE (ASSUMED) 2,000 PSF
SOILS REPORT AVAILABLE NO
*SEISMIC LOAD:*SEISMIC LOAD:
SEISMIC USE GROUP / RISK CATEGORY II
SEISMIC LOAD IMPORTANCE FACTOR (Ie) 1.1
SEISMIC SITE CLASS D (ASSUMED)
MAPPED SPECTRAL RESPONSE ACCELERATION (Ss) 0.072
MAPPED SPECTRAL RESPONSE ACCELERATION (S1) 0.047
SPECTRAL RESPONSE COEFFICIENT (Sds) 0.077
SPECTRAL RESPONSE COEFFICIENT (Sd1) 0.075
SEISMIC DESIGN CATEGORY A
SEISMIC RESPONSE COEFF. CS 0.026
RESPONSE MODIFICATION COEFF. 3.00
LONDITUDINAL BASE SHEAR 0.026 x W KIPS
TRANSVERSE BASE SHEAR 0.026 x W KIPS
*WIND LOAD:*WIND LOAD:
ULTIMATE WIND SPEED 115 MPH (Vult)
NOMINAL WIND SPEED 89 MPH (Vasd)
RISK CATEGORY II-STANDARD BUILDINGS
WIND EXPOSURE C
INTERNAL PRESSURE COEFFICIENTS ± 0.18
ROOF DESIGN LOAD:ROOF DESIGN LOAD:
SNOW ROOF LOAD 21.0 PSF
GROUND SNOW LOAD 30.0 PSF
ROOF LIVE LOAD 20.0 PSF
ROOF DEAD LOAD PER MFG
COLLATERAL LOAD 5.0 PSF
UNBALANCED LOAD: N/A
DRIFT LOADS SEE APPROPRIATE DIAGRAMS
ON S2.0
*SNOW LOAD:*SNOW LOAD:
GROUND SNOW LOAD 30 PSF
SNOW EXPOSURE FACTOR (Ce) 1.0
SNOW IMPORTANCE FACTOR (Is) 1.0
THERMAL FACTOR (Ct) 1.0
RISK CATEGORY II
* SEISMIC, WIND, AND SNOW LOAD CALCULATIONS AND DESIGN DATA SHALL BE PERFORMED * SEISMIC, WIND, AND SNOW LOAD CALCULATIONS AND DESIGN DATA SHALL BE PERFORMED
AND SUPPLIED BY THE TRUSS MANUFACTURER.AND SUPPLIED BY THE TRUSS MANUFACTURER.
FOUNDATION PLAN NOTES:FOUNDATION PLAN NOTES:
1. CONTRACTOR SHALL PROVIDE FROST PROTECTION AND MOISTURE PROTECTION
FOR FOOTINGS EXPOSED DURING CONSTRUCTION.
2. REFER TO ARCHITECTURAL DRAWINGS OR PLUMBING DRAWINGS FOR SPECIFIC
FLOOR DRAIN LOCATIONS AND ELEVATIONS.
3. REFER TO STRUCTURAL DETAIL PLAN SHEETS FOR MISCELLANEOUS DETAILS NOT
INDICATED ON PLAN.
4. NOTIFY ENGINEER OF ANY UNUSUAL SOIL CONDITIONS. ALL FOOTINGS
SHALL REST ON UNDISTURBED ROCK OR SOIL EXCAVATIONS FOR FOOTINGS
SHALL BE APPROVED BY ENGINEER PRIOR TO PLACEMENT OF CONCRETE.
5. WHERE REQUIRED, REMOVE UNSUITABLE EXISTING SOILS BELOW FOOTINGS,
SLABS-ON-GRADE, ETC. TO APPROVED BEARING SOIL. REPLACE WITH ENGINEERED
FILL (COMPACTED TO 95% OF THE MODIFIED PROCTOR DENSITY) TO THE REQUIRED
FOOTING BEARING ELEVATION. REVIEW SOIL REPORT, IF ANY, FILL MATERIAL SHALL
HAVE A MINIMUM BEARING CAPACITY AS INDICATED IN THE STRUCTURAL DESIGN DATA
SOIL LOAD INFORMATION ON SHEET S0.0. TYPE OF FILL MATERIAL AND PLACEMENT
SHALL CONFORM TO SPECIFICATIONS UNDER THE DIRECTION AND SUPERVISION
OF THE SOILS ENGINEER. SOILS ENGINEER SHALL FIELD VERIFY ALL BEARING
CAPACITIES BEFORE FOOTINGS ARE POURED. CONTACT ENGINEER IF UNABLE
TO ATTAIN LISTED SOIL BEARING PRESSURE.
6. PROVIDE A MINIMUM OF 8 INCHES OF WELL COMPACTED GRANULAR FILL BELOW
ALL SLABS ON GRADE. COMPACT TO 95% OF THE MODIFIED PROCTOR DENSITY.
7. CONCRETE EXPOSED TO WEATHER (RETAINING WALLS, EXTERIOR SLABS, WALKS,
CURBS, ETC. BUT EXCLUDING EXPOSED FOUNDATION WALLS) SHALL CONTAIN 4 TO
7 PERCENT AIR BY VOLUME.
8. DELIVERY TICKETS FOR EACH LOAD OF CONCRETE DELIVERED TO THE JOB SITE
SHALL BE FURNISHED UPON REQUEST TO THE ENGINEER. TICKET INFORMATION
SHALL CONTAIN ALL PERTINENT DESIGN INFORMATION, INCLUDING AMOUNT OF
WATER ADDED AT THE JOB SITE, IF ANY.
9. VERIFY PIER CENTERLINE SPACINGS, ANCHOR BOLT LAYOUT, AND FOUNDATION
DIMENSIONS WITH METAL BUILDING MANUFACTURER'S ANCHOR BOLT PLAN. VERIFY
THAT ALL BASE PLATES WILL BEAR FULLY ON CONCRETE PIERS, NOTIFY ENGINEER
OF ANY DISCREPANCIES PRIOR TO POURING CONCRETE.
10. FORMWORK FOR FOOTINGS SHALL CONSIST OF A MANUFACTURED FORM SYSTEM
OR A MINIMUM 1-1/2" THICK WOOD PLANK SECURED TO WOOD OR STEEL STAKES.
POURING TO EXCAVATION BANK MAY NOT BE DONE WITHOUT PRIOR APPROVAL OF
THE ENGINEER.
11. MIXING AND PLACING OF CONCRETE TO BE IN ACCORDANCE WITH ACI 318.
CONCRETE SHALL BE DEPOSITED AS NEARLY AS PRACTICAL IN ITS FINAL POSITION
TO AVOID SEGREGATION DUE TO REHANDLING OR FLOWING. CONCRETING SHALL
BE CARRIED ON A SUCH A RATE THAT CONCRETE IS AT ALL TIMES PLASTIC AND
FLOWS READILY INTO SPACES BETWEEN REINFORCEMENT. ALL CONCRETE SHALL BE
THOROUGHLY CONSOLIDATED BY SUITABLE MEANS DURING PLACEMENT AND SHALL
BE THOROUGHLY WORKED AROUND REINFORCEMENT AND EMBEDDED FIXTURES
AND INTO CORNERS OF FORMS.
MATERIAL DESIGN PROPERTIES:MATERIAL DESIGN PROPERTIES:
CONCRETE PROPERTIES:CONCRETE PROPERTIES:
REINFORCING STEEL STRENGTHS:REINFORCING STEEL STRENGTHS:
BARS (ASTM A615, GRADE 60) fy = 60,000 PSI
WELDED WIRE MESH (ASTM A 185) fy = 65,000 PSI
STRUCTURAL STEEL STRENGTHS:STRUCTURAL STEEL STRENGTHS:
OTHER:
W SHAPES (ASTM A992, GR50) fy = 50,000 PSI
ANGLES, CHANNELS,PLATES, & BARS (ASTM A36) fy = 36,000 PSI
SQUARE & RECTANGULAR TS OR HSS SECTIONS (ASTM A500 ,GR B) fy = 42,000 PSI
HIGH STRENGTH BOLTS (ASTM A325)
USE USE 28 DAY 28 DAY
STRENGTH STRENGTH
MIN. H2O /CEMENTMIN. H2O /CEMENT
RATIO RATIO
SLUMP SLUMP
(INCHES) (INCHES)
MAX. MAX.
AGGREGATE SZ.AGGREGATE SZ.
INTERIOR FLOORS 3,500 PSI .62 3 ±1 3/4
WALLS 3,500 PSI .62 3 ±1 3/4
PIERS 3,500 PSI .62 3 ±1 3/4
FOOTINGS 3,500 PSI .62 3 ±1 1-1/2
EXTERIOR FLOORS 4,000 PSI .48 4 ±1 3/4
2. ALL CONCRETE SUBJECT TO EXTERIOR EXPOSURE SHALL BE AIR ENTRAINED TO 6% (+/- 1.5% ) AND HAVE A
MAXIMUM 3/4” AGGREGATE. ALL CONCRETE WITHOUT UPERPLASTICIZERS SHALL HAVE A MAXIMUM SLUMP OF 4 ” ± 1".
1. ALL CONCRETE DESIGN AND CONSTRUCTION SHALL CONFORM TO THE LOCAL BUILDING CODE REQUIREMENTS AND
THOSE OF THE LATEST EDITION OF THE FOLLOWING STANDARDS: ACI 318, ACI 315, ACI 301, AND ACI 305 & 306.
MISCELLANEOUS STRUCTURAL NOTES:MISCELLANEOUS STRUCTURAL NOTES:
1. ENGINEER ASSUMES PIN BASED COLUMNS.
2. CONNECTORS:CONNECTORS:
A. FOR EXTERIOR AND INTERIOR APPLICATIONS WHERE EXPOSED TO MOISTURE, WHERE PRESSURE
TREATED WOOD IS USED, AND FOR INTERIOR CORROSIVE ENVIRONMENTS ALL CONNECTORS
SHALL BE HOT DIPPED GALVANIZED PER ASTM A 153A / 153M, OR STAINLESS STEEL, INCLUDING
EXPANSION BOLTS, ANCHOR BOLTS, JOIST HANGERS, AND NAILS.
B. CONNECTION DESIGN TO WOOD OR STEEL FRAMING AND EVALUATION OF STRUCTURAL MEMBERS
ADEQUACY BY A REGISTERED PROFESSIONAL ENGINEER SHALL BE PROVIDED BY ALL
SUBCONTRACTORS.
C. INSTALLER OF ANCHORS OR CONNECTIONS TO STRUCTURE IS RESPONSIBLE FOR ANCHOR
DESIGN AND DETERMINATION OF STRUCTURAL COMPONENT ADEQUACY. DO NOT CUT
REINFORCING BARS OR DAMAGE OTHER EMBEDMENTS.
3. WORK BY OTHERS:WORK BY OTHERS:
A. ALL SUPPORTS, FRAMING, SUB-FRAMING, LIGHT GAGE FRAMING, MISCELLANEOUS STEEL FRAMING,
METAL FABRICATIONS, BRACING BRACKETS, HANGERS, CONNECTORS, EMBEDMENTS, FASTENERS,
AND ATTACHMENTS NOT SHOWN ON THE STRUCTURAL DRAWINGS ARE THE CONTRACTOR'S
RESPONSIBILITY AND SHALL BE ENGINEERED AND PROVIDED BY THE CONTRACTOR REQUIRING
THE ITEM. COMPLY WITH GOVERNING CODES.
B. CONSTRUCTION MEANS AND METHODS ARE THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE
ENGINEERED AND PROVIDED BY THE CONTRACTOR REQUIRING SUCH, WORK INCLUDES,
BUT IS NOT LIMITED TO:
1. EVALUATION OF STRUCTURE FOR CONSTRUCTION EQUIPMENT LOADS SUCH AS FORKLIFTS,
MATERIAL STOCKPILES, ETC.
2. EVALUATION OF STRUCTURE FOR INSTALLATION OF ANY NECESSARY SHORING FOR MOVING
LOADS DURING INSTALLATION OF HEAVY EQUIPMENT.
4. WHERE DIMENSIONS OR WEIGHTS OF EQUIPMENT OR SYSTEMS ARE VARIABLE FROM MANUFACTURER
TO MANUFACTURER, VERIFY DIMENSIONS AND WEIGHTS SHOWN ON DRAWINGS WITH SELECTED
MANUFACTURER PRIOR TO ORDERING MATERIALS, NOTIFY ENGINEER OF DISCREPANCIES.
5. DO NOT SUSPEND POINT LOADS FROM ROOF SHEATHING OR ROOF PURLINS UNLESS APPROVED BY
THE ENGINEER. POINT LOADS INCLUDE, BUT ARE NOT LIMITED TO: HANGERS FOR CEILINGS, PIPES,
DUCTS, STEEL STUDS, EQUIPMENT, ETC. CONTRACTOR INSTALLING SUCH POINT LOADS SHALL
PROVIDE SUB-FRAMING TO TRANSFER LOAD TO THE STRUCTURE SUPPORTING DECK.
CONCRETE CAST-IN-PLACE NOTES:CONCRETE CAST-IN-PLACE NOTES:
1. ALL CONCRETE DESIGN AND CONSTRUCTION SHALL CONFORM TO THE LOCAL BUILDING CODE REQUIREMENTS AND
THOSE OF THE LATEST EDITION OF THE FOLLOWING STANDARDS: ACI 318, ACI 315, ACI 301, AND ACI 305 & 306.
2. CONCRETE SLABS ON GROUND CONTAINING REINFORCEMENT SHALL PLACE ALL REINFORCING BARS AND WWF ON
CHAIRS, TIED IN PLACE, AND LOCATED IN THE MIDDLE TO THE UPPER ONE-THIRD OF THE SLAB. LIFTING REINFORCING
AFTER CONCRETE IS PLACED IS NOT CONSIDERED TO BE AN EFFECTIVE MEANS OF PLACEMENT AND SHALL NOT BE
ALLOWED WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. WELDED WIRE REINFORCEMENT FABRIC SHALL BE
SUPPORTED WITH APPROVED MATERIALS OR SUPPORTS AT SPACING NOT TO EXCEED 3 FEET OR IN ACCORDANCE WITH
THE MANUFACTURER'S SPECIFICATIONS. WELDED PLAIN WIRE REINFORCEMENT FABRIC FOR CONCRETE SHALL
CONFORM TO ASTM A 185.
3. ALL CONCRETE MIX DESIGNS SHALL MINIMIZE SHRINKAGE AS MUCH AS IS PRACTICAL. INCLUDING SELECTION OF
AGGREGATE TYPE, SIZE, GRADATIONS W/ C RATIO AND ADD MIXTURES.
4. UNLESS THE MIX DESIGN INCLUDES THE USE OF SUPERPLASTICIZERS, CONCRETE WITH A SLUMP GREATER THAN 5”
SHALL BE REFUSED.
5. ALL CONCRETE REINFORCING STEEL TO BE ASTM A615 GRADE 60. ALL WELDED WIRE FABRIC (WWF) TO BE ASTM A -
185. ALL REINFORCING SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI 315 AND 315R.
6. ALL REINFORCING BARS AND WWF SHALL BE SET ON CHAIRS AND TIED IN PLACE.
7. AFTER CONCRETING HAS STARTED, IT SHALL BE CARRIED ON AS A CONTINUOUS OPERATION UNTIL PLACING OF A
PANEL OR SECTION, AS DEFINED BY ITS BOUNDARIES OR PREDETERMINED JOINTS, IS COMPLETED. CONCRETE SHALL
BE DEPOSITED AS NEARLY AS PRACTICABLE TO ITS FINAL POSITION TO AVOID SEGREGATION DUE TO REHANDLING OR
FLOWING.
8. CONCRETING OPERATIONS SHALL BE CARRIED ON AT SUCH A RATE THAT THE CONCRETE IS AT ALL TIMES PLASTIC
AND FLOWS READILY INTO SPACES BETWEEN REINFORCEMENT.
9. CONCRETE SHALL BE THOROUGHLY CONSOLIDATED BY SUITABLE MEANS DURING PLACEMENT AND SHALL BE
THOROUGHLY WORKED AROUND REINFORCEMENT AND EMBEDDED FIXTURES AND INTO CORNERS OF THE FORMS. THE
TOP SURFACES OF VERTICALLY FORMED LIFTS SHALL BE GENERALLY LEVEL.
10. CONCRETE SHALL BE CURED ABOVE 50°F (10°C) AND IN A MOIST CONDITION FOR AT LEAST THE FIRST SEVEN DAYS
AFTER PLACEMENT. DO NOT PLACE CONCRETE WHEN DURING ANY POINT IN THE DAY THE MEAN DAYLIGHT
TEMPERATURE IS LESS THAN 20°F.
11. ALL FLAT WORK CONCRETE SHALL BE COVERED IMMEDIATELY FOLLOWING SAW CUTTING AND MAINTAINED
CONTINUOUSLY WET FOR A MINIMUM OF 7-DAYS AFTER PLACING. CURING SHEETS ARE TO BE USED AND REMAIN IN
PLACE. CURING COMPOUNDS MAY BE USED APPLIED MUST BE APPLIED PER THE MANUFACTURES RECOMMENDATIONS.
SUBMIT PRODUCT DATA TO A/E FOR APPROVAL.
12. RETEMPERED CONCRETE, CONCRETE THAT HAS BEEN REMIXED AFTER INITIAL SET OR PARTIALLY HARDENED SHALL
NOT BE USED IN THE STRUCTURE.
13. ALL LAPS SHALL BE “B” SPLICES UNLESS NOTED OTHERWISE ON THE DRAWINGS OR UNLESS SPECIAL CARE IS TAKEN
FOR THE REINFORCING TO BE DETAILED AND PLACED TO PROVIDE STAGGERED LAPS.
14. UNLESS OTHERWISE APPROVED, ALL EXPOSED CONCRETE WALLS SHALL BE CURED WITH FORMS LEFT IN PLACE FOR
SEVEN DAYS. IF FORMS CAN NOT BE LEFT IN PLACE THE CONTRACTOR SHALL SUBMIT IN WRITING TO THE ENGINEER
ALL PROPOSED CURING METHODS.
15. WALL CRACKS DUE TO IMPROPER CURING METHODS, OR WEATHER PROTECTION SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
16. ANCHOR BOLT DIAMETER AND PLACEMENT TO BE PER THE METAL BUILDING SUPPLIER'S DRAWINGS. ANCHOR RODS
SHALL BE A MINIMUM OF (4) 3/4” DIAMETER F1554, GRADE 36, WITH A 9" MINIMUM EMBEDMENT UNLESS NOTED
OTHERWISE. THREADED RODS SHALL HAVE A NUT AND WASHER SECURED TO THE EMBEDDED END EITHER BY WELD OR
DOUBLE NUT.
17. THREADED RODS SHALL HAVE A NUT AND WASHER SECURED TO THE EMBEDDED END EITHER BY WELD OR DOUBLE
NUT.
18. GROUT USED TO PROVIDE LEVEL BEARING OF COLUMN BASE PLATES SHALL BE NON-SHRINK, NON-METALLIC GROUT
WITH A COMPRESSIVE STRENGTH 500 PSI OR MORE GREATER THAN THE COMPRESSIVE STRENGTH OF THE
SUPPORTING CONCRETE MEMBER.
19. EPOXY FOR EPOXY GROUTED ANCHORS SHALL BE A TWO PART 100% SOLID EPOXY SUPPLIED AND DISPENSED THOUGH
A STATIC MIXING NOZZLE SUPPLIED BY THE MANUFACTURE. DRILLED HOLES MUST BE BRUSHED CLEAN AND BLOWN
OUT PRIOR TO INSTALLATION OF THE ANCHORS. FOLLOW ALL SUPPLIERS INSTRUCTIONS FOR INSTALLATION.
20. UNLESS NOTED OTHERWISE ON THE DRAWINGS ALL REINFORCING SHALL BE LAPPED TO DEVELOP ITS CAPACITY AS
FOLLOWS:
UNCOATED STANDARD & CLASS "B" TENSION LAP LENGTHS UNCOATED STANDARD & CLASS "B" TENSION LAP LENGTHS
CONCRETE COMPRESSIVE STRENGTH = 3,500 PSI CONCRETE COMPRESSIVE STRENGTH = 4,000 PSI
BAR
SIZE
STD DEVELOPMENT
LENGTH
#3
BTM
BARS
TOP
BARS
CLASS "B" LAP
LENGHT
BTM
BARS
TOP
BARS
15" 20" 20" 26"
BAR
SIZE
STD DEVELOPMENT
LENGTH
BTM
BARS
TOP
BARS
CLASS "B" LAP
LENGHT
BTM
BARS
TOP
BARS
#3 14" 18" 18" 23"
#4 20" 30" 30" 39"
#5 25" 38" 38" 50"
#6 30" 46" 46" 60"
#7 35" 53" 53" 69"
#8 41" 61" 61" 79"
NOTES:
1. BASED ON _d VALUES FROM SECTION 25.4.2.2 IN ACI 318-14:
1.1 GRADE 60 REINFORCEMENT BARS
1.2 NORMAL WEIGHT CONCRETE (_=1.0)
1.3 NON-EPOXY COATED BARS (_=1.0)
1.4 CLEAR COVER > 1.0db; CLEAR SPACING > 2.0db; NOTIFY ENGINEER IF COVER NOT MET.
2. STANDARD LAB SPLICES ARE TO BE USED WHEN < 50% OF BARS ARE LAPPED AT THE SAME LOCATION,
INCLUDING TEMPERATURE AND SHRINKAGE LAP SPLICES.
2.1 PROVIDE CLASS B LAP SPLICES UNLESS DETAILED AND APPROVED BY ENGINEER.
3. CLASS B LAP SPLICES ARE TO BE USED WHEN > 50% OF BARS ARE LAPPED AT THE SAME LOCATION,
INCLUDING TEMPERATURE AND SHRINKAGE LAP SPLICES.
4. HORIZONTAL (TOP) BARS HAVE MORE THAN 12" OF FRESH CONCRETE PLACED BELOW
REINFORCEMENT. SPLICE LENGTHS ARE ROUNDED UP TO THE NEAREST INCH.
19" 25" 25" 33"
24" 31" 31" 40"
28" 37" 37" 48"
33" 43" 43" 56"
38" 49" 49" 64"
#4
#5
#6
#7
#8
21. SLAB ON GRADE SHALL HAVE A CLASS "A" TOLERANCE.
22. A 10-MIL. (MIN.) POLYETHYLENE VAPOR BARRIER WITH JOINTS LAPPED NOT LESS THAN 6” SHALL BE
PLACED BETWEEN THE BASE COURSE OR SUBGRADE AND THE CONCRETE FLOOR.
23. CALCIUM CHLORIDE AND OR ADMIXTURES CONTAINING CALCIUM CHLORIDE SHALL NOT BE USED.
24. PLACING OF CONCRETE SHALL BE DONE IN CONFORMANCE WITH ACI-306 FOR COLD WEATHER AND
ACI-305 FOR HOT WEATHER.
25. EXPOSED FOUNDATION WALLS SHALL HAVE VERTICAL CONTROL JOINTS SPACED NOT MORE THAN
25'- 0” ON CENTER. EACH JOINT SHALL BE 3/ 4” WIDE BY 1/ 4 WALL DEPTH DEEP AND V-CHAMFERED
ON BOTH SIDES. HORIZONTAL WALL REINFORCING SHALL BE DISCONTINUOUS AT THE CONTROL
JOINT LOCATION WITH GREASED SMOOTH DOWEL BARS AT 16” ON CENTER THRU THE JOINT. THE
LOCATION OF WALL CONTROL JOINTS SHALL BE MID BAY BETWEEN COLUMNS.
26. EXPOSED FOUNDATION WALLS SHALL HAVE EXPANSION JOINTS LOCATED AT EVERY FOURTH
CONTROL/CONTRACTION JOINT. SEE CONCRETE DETAILS FOR SPECIFIC CONSTRUCTION
REQUIREMENTS.
27. FLOOR SLAB CONTROL JOINTS SHALL FOLLOW THE INTENT SHOWN ON THE PLAN BUT SHALL NOT
EXCEED AN ASPECT RATIO OF 1.5 TO 1.0. ALL REENTRANT CORNERS SHALL HAVE CONTROL JOINTS
EXTENDING OUT FROM THE INSIDE CORNER. DEAD-END “T” CONTROL JOINTS INTO CONTINUOUS
JOINTS SHALL BE AVOIDED.
28. WALL EXPANSION JOINTS ARE REQUIRED WHERE INDICATED ON THE DRAWINGS BUT NOT TO EXCEED
125 FEET.
29. NO TACK WELDING WILL BE PERMITTED ON ASTM A615 GRADE 40 OR 60 STEEL.
30. CONTROL JOINTS SHALL BE CUT IN SLAB-ON-GRADE CONSTRUCTION WITHIN 24 HOURS OF INITIAL
POUR.
31. CONSTRUCTION JOINTS SHALL BE LOCATED AT CONTROL JOINTS OR CONTRACTION JOINTS.
32. ALL SLAB-ON-GRADE SHALL UTILIZE 1.5 INCH TOP AGGREGATE IN AN EVENLY DISTRIBUTED
AGGREGATE GRADATION.
33. PIPE SLEEVES OVER 1 1/2" IN DIAMETER WHICH PASS THROUGH CONCRETE WALLS OR SLABS SHALL BE
SCHEDULE 40 GALVANIZED STEEL PIPE. ALL OTHER SLEEVES SHALL BE 18 GAUGE SHEET METAL.
SLEEVES SHALL BE ON SIZE LARGER THAN OUTSIDE DIAMETER OF THE PIPE PASSING THROUGH THE
SLEEVE. VERIFY SIZE AND NUMBER WITH MECHANICAL, ELECTRICAL, AND PLUMBING CONTRACTOR.
34. ALUMINUM CONDUIT SHALL NOT BE EMBEDDED IN CONCRETE.
CONCRETE REINFORCEMENT NOTES:CONCRETE REINFORCEMENT NOTES:
1. REINFORCING SHALL BE DETAILED IN ACCORDANCE WITH ACI 315 MANUAL OF STANDARD PRACTICE
FOR DETAILING REINFORCED CONCRETE STRUCTURES (MOST CURRENTLY ADOPTED EDITION).
2. PROVIDE MINIMUM COVER PER ACI 318, 7.7.1 ALSO SEE MILD STEEL PROTECTION NOTES .
3. WIRE SPACERS, CHAIRS, TIES, ETC. FOR SUPPORT OF STEEL REINFORCING SHALL BE PROVIDED BY
THE CONCRETE CONTRACTOR TO ENSURE REINFORCING IS PLACED AND MAINTAINED IN THE
PROPER POSITION DURING CONCRETE PLACEMENT.
4. ALL HOOKS IN STEEL REINFORCING SHALL BE ACI STANDARD HOOKS.
5. TERMINATE NON-CONTINUOUS STEEL REINFORCING WITH AN ACI STANDARD HOOK IF REQUIRED
EMBEDMENT SHOWN ON DRAWINGS CANNOT BE OBTAINED.
6. ALL LAPS SHALL BE CLASS "B" PER ACI 318 ON THE DESIGN DRAWINGS, OR UNLESS THE
DETAILER TAKES SPECIAL CARE TO PROVIDE STAGGERED LAPS. USE TO BAR LENGTHS FOR ALL
HORIZONTAL WALL BARS AND FOR TOP BARS IN SLABS AND BEAMS OVER 12" DEEP.
7. STEEL REINFORCING SPLICES OF ADJACENT BARS SHALL BE STAGGERED SUCH THAT SPLICES ARE
4 FEET APART, MINIMUM.
8. CORNER BARS WITH CLASS "B" LAP PER ACI318 SHALL BE PROVIDED AT ALL WALL CORNERS AND
AND INTERSECTIONS.
9. PROVIDE STEEL REINFORCING AROUND OPENINGS IN CONCRETE WALLS AND SLABS.
10. PROVIDE STEEL REINFORCING AT FOOTING STEPS.
11. WELDED WIRE REINFORCING SHALL BE IN FLAT SHEETS ONLY AND SHALL BE LAPPED AND/OR
ANCHORED TO DEVELOP Fy PER ACI 315.
12. WELDING OF STEEL REINFORCEMENT IS NOT PERMITTED, UNLESS APPROVED BY ENGINEER.
2"+
6" MIN.
MILD REINFORCING STEEL PROTECTION NOTES:MILD REINFORCING STEEL PROTECTION NOTES:
THE FOLLOWING MINIMUM DIMENSIONS SHALL BE PROVIDED AS A CLEAR COVER FOR
REINFORCING BARS IN STRUCTURAL MEMBERS:
CONCRETE CAST AGAINST EARTH AND PERMANENTLY EXPOSED TO EARTH:
FOOTINGS 3"
CONCRETE PERMANENTLY EXPOSED TO EARTH OR WEATHER:
WALLS, COLUMNS, PIERS:
UP THROUGH #5 BARS 1-1/2"
#6 THROUGH #18 BARS 2"
CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
WALLS:
UP THROUGH #11 BARS 3/4"
#14 AND #18 BARS 1-1/2"
COLUMNS / PIERS:
SIDES 1-1/2"
FROST WALL SCHEDULEFROST WALL SCHEDULE
MARK MARK
DIMENSIONSDIMENSIONS
WIDTH WIDTHLENGTH LENGTHDEPTH DEPTH
REINFORCEMENTREINFORCEMENT TOP OF TOP OF
ELEV ELEV
REMARKS REMARKS
PIER 1
FOOTING SCHEDULEFOOTING SCHEDULE
MARK MARK
DIMENSIONSDIMENSIONS
WIDTH WIDTHLENGTH LENGTHDEPTH DEPTH
REINFORCEMENTREINFORCEMENT
(W)- SPAN WIDTH
(L)- SPAN LENGTH
TOP OF TOP OF
ELEV ELEV
REMARKS REMARKS
F1
F2
18" 24" 4'-0"
(10) #6 VERTICAL BARS W/
#3 TIES @ 12" O.C.
TOP 4 TIES @ 3" O.C.
100'-0"
1'-0"
1'-0" #5 BARS @ 12" O.C. , E.W. 96'-0"
96'-0"#5 BARS @ 12" O.C. , E.W.
6'-0" 6'-0"
4'-0" 4'-0"
NOTE: NOTE: PRIOR TO CONSTRUCTION CONTRACTOR TO VERIFY PIER SIZES WITH METAL BUILDING MFG'S BASE
PLATE AND ANCHOR BOLT LAYOUTS
PIER 2 18" 17 1/2" 4'-0"
(8) #6 VERTICAL BARS W/
#3 TIES @ 12" O.C.
TOP 4 TIES @ 3" O.C.
100'-0"
F3 7'-0" 5'-0" 1'-0" 96'-0"
PIER 3 19" 22" 4'-0"
(12) #6 VERTICAL BARS W/
#3 TIES @ 12" O.C.
TOP 4 TIES @ 3" O.C.
100'-0"
PIER 4 19" 22" 4'-0"
(12) #6 VERTICAL BARS W/
#3 TIES @ 12" O.C.
TOP 4 TIES @ 3" O.C.
100'-0"
PIER 5 19" 14" 4'-0"
(8) #6 VERTICAL BARS W/
#3 TIES @ 12" O.C.
TOP 4 TIES @ 3" O.C.
100'-0"
STRIP 16" 1'-4" CONT. 1'-0" (2) #5 BARS, CONT. 96'-0"
#5 BARS @ 12" O.C. , E.W.
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
S001 S001
0924-25
11/11/25
SSR STRUCTURAL NOTES2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
REVISIONS NO. DATE
6" CONCRETE SLAB
W.W.F 6x6-8X8 (W2.1XW2.1)
6 MIL VAPOR BARRIER, &
8" COMPACTED GRANULAR FILL
TIE BACK: 4" BELOW FINISH GRADE
18" X 12" THICKEN SLAB W/ (5) #7 BARS
W/ MECH. SPLICES
#5 X 10' LONG HAIRPINS, TYP.
DD
CC
BB
AA
1 2 3 4
4
5
6' - 0"
6' - 0"
H1 H1 H1
30' - 0"30' - 0"30' - 0"
90' - 0"
12' - 0" 30' - 0" 30' - 0" 28' - 0"
100' - 0"
4' - 0"
4' - 0"
4' - 0"
4' - 0"
5' - 0"
7' - 0"
30' - 0" 30' - 0" 30' - 0"
90' - 0"
#5 X 10' LONG HAIRPINS, TYP.
PIER 2 PIER 2PIER 2
TOF: 96' - 0"TOF: 96' - 0"
FTG 3 FTG 3 TOF: 96' - 0"TOF: 96' - 0"
FTG 3 FTG 3
TOF: 96' - 0"TOF: 96' - 0"
FTG 3 FTG 3
PIER 3
PIER 5
PIER 5
PIER 4
PIER 1
PIER 1 PIER 1
PIER 5
PIER 5
1' - 2"
TOF: 96' - 0"TOF: 96' - 0"
FTG 1 FTG 1 TOF: 96' - 0"TOF: 96' - 0"
FTG 1 FTG 1
TOF: 96' - 0"TOF: 96' - 0"
FTG 1 FTG 1
A1
8"
1' - 4"
PIER 3
1' - 4"
PIER 4
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
2 2
S111 S111
______________________
1 1
S111 S111
______________________
3 3
S111 S111
______________________
4 4
S111 S111
______________________
8" DROP WALL
5 5
S111 S111
______________________
(1) SHEET 4'X8'X2" RIGID INSULATION
BELOW SLAB AT SERVICE DOOR, TYP.
(1) SHEET 4'X8'X2" RIGID INSULATION
BELOW SLAB AT SERVICE DOOR, TYP.
3 3
A-610 A-610
Sim Sim
______________________
8" DROP WALL
3' - 4"
2' - 7 1/2"
12' - 0" 4' - 1 1/4"
1
1.5
CONTINUE WELDED WIRE
REINFORCING THROUGH
THICKENED SLABS IF APPLICABLE
NOTE:
1. (4) # 6 TIE RODS WITH MECHANICAL (TENSION) SPLICES
MECH. SPLICE TO DEVELOP 125% OF BAR TENSION.
USE D250SCA Bar Lock® Coupler BY DAYTON SUPERIOR
OR EQUAL
2. 17" X 12" THICKEN SLAB AT MAIN FRAME GRID LINES
1' - 6"
6"6"
3"
LONG. GRADE BEAMS B/W STEEL FRAMES
4" 4" 4"
SEE PLAN
T6"
NOTES: NOTES:
1. SAW CUT JOINTS WITH EARLY ENTRY SAW AS SOON AS THE SLAB CAN SUPPORT THE
WEIGHT OF THE SAW CUTTING EQUIPMENT AND CUTTING DOES NOT DAMAGE THE SLAB.
2. INSTALL JOINTS INDICATED ON PLANS UNO. SUBMIT PROPOSED ALTERNATE LOCATIONS
OR ADDITIONAL JOINTS NOT SHOWN TO THE DOR FOR APPROVAL. PROPOSED ALTERNATE
LOCATIONS MAY BE REJECTED. MAX JOINT SPACING MUST BE BETWEEN (24 TO 36) x SLAB THICKNESS. MAX
POUR LENGTH MUST BE 100'-0" BETWEEN CONSTRUCTION JOINTS. RATIO OF LENGTH TO
WIDTH MUST NOT EXCEED 1.5. TOTAL AREA OF POUR MUST NOT EXCEED 10,000 SF
BETWEEN CONSTRUCTION JOINTS.
3. DISCONTINUE REINFORCEMENT AT CONSTRUCTION JOINTS.
3/4"øx10" SMOOTH DOWEL @ 12" OC
LUBRICATE ONE END OR SET FIRST
PLACEMENT END IN APPROVED
PLASTIC INSERT
2nd pour 1st pour
2"
1/8"xT/4" CONTINUOUS SAW CUT
(1" MIN) OR STRIP INSERT W/ JT.
FILLER & ELASTOMERIC
SEALANT.APPLY CURING COMPOUND
TO SLAB EDGE IMMEDIATELY
AFTER FORM IS REMOVED
CONSTRUCTION JOINTCONSTRUCTION JOINT
1/8"xT/4" CONTINUOUS SAW CUT
(1" MIN) OR STRIP INSERT W/ JT.
FILLER & ELASTOMERIC
SEALANT.
SLAB ON GRADESLAB ON GRADE
3/16" MAX
1/8" MIN
1" MIN
T/4
INDUCED CRACK
SAWN CONTROL JOINTSAWN CONTROL JOINT
SEE PLAN
T 6"
WWR OR REINF
BAR PER PLAN
TYP
SLAB ON GRADE
SEE PLAN FOR THICKNESS
AND REINFORCING
1/2 x T MAX
1/3 x T MIN
BOT/REINF
SCALE: 1/16" = 1'-0" on 11" x 17"
1/8" = 1'-0" on 22" x 34"
FOUNDATION PLANFOUNDATION PLAN
1 1
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
S100 S100
0924-25
11/11/25
SSR FOUNDATION PLAN2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
NOT TO SCALE
FRAME TIE BACKFRAME TIE BACK3 3
REVISIONS NO. DATE
BASE PLATE THICKNESS PER MFG.
BP: A1& D1 (4)~3/4" DIA. J-BOLTS GR36
& W/ MIN. 12" EMBEDMENT
ELEV.=100'-0"ELEV.=100'-0"
PIER 4 SOUTH WALL CORNERSPIER 4 SOUTH WALL CORNERS
PIER DETAILSPIER DETAILS
BL BL
BL BL
FND PIER
W/ (12) #6 VERT. BARS
& #3 TIES @ 12" O.C. &
TOP 4 TIES @ 3" O.C.
BASE PLATE THICKNESS PER MFG.
BP: G1: (4)~1" DIA. Ø THREADED ROD F1554
GR36 W/ DOUBLE NUT ON END & W/ MIN. 12"
EMBEDMENT.
ELEV.=100'-0"ELEV.=100'-0"
PIER 2: G1 BASE PLATEPIER 2: G1 BASE PLATE
11"
BASE PLATE THICKNESS PER MFG.
BP: C1, F1 (4)~3/4" DIA. J-BOLTS GR36
& W/ MIN. 12" EMBEDMENT
ELEV.=100'-0"ELEV.=100'-0"
PIER 3 NORTH WALL CORNERSPIER 3 NORTH WALL CORNERS
BL BL
BL BL
FND PIER
W/ (12) #6 VERT. BARS
& #3 TIES @ 12" O.C. &
TOP 4 TIES @ 3" O.C.
8"
8" 11"
8"
19"
BL BL BL BL
18"
FND PIER W/ (10) #6 VERT. BARS
& #3 TIES @ 12" O.C. &
TOP 4 TIES @ 3" O.C.
2' - 0"
9" 9"
1' - 0"
1' - 0"
BASE PLATE THICKNESS PER MFG.
BP: H1: (4)~1" DIA. Ø THREADED ROD F1554
GR36 W/ DOUBLE NUT ON END & W/ MIN. 12"
EMBEDMENT.
ELEV.=100'-0"ELEV.=100'-0"
PIER 1: BASE PLATE H1 PIER 1: BASE PLATE H1
H1
1'-6" X 1'-0" GRADE BEAM
W/ (4) # 6 TIE RODS WITH
MECHANICAL SPLICES
8"
1' - 4"
7"
BL BL BL BL
18"
FND PIER W/ (8) #6 VERT. BARS
& #3 TIES @ 12" O.C. &
TOP 4 TIES @ 3" O.C.
1'-8" X 1'-0" GRADE BEAM
W/ (4) # 6 TIE RODS WITH
MECHANICAL SPLICES
8"
1' - 5 1/2"
22"
8"
8"
BL BL
BL BL
14"
FND PIER W/ (8) #6 VERT. BARS
& #3 TIES @ 12" O.C. &
TOP 4 TIES @ 3" O.C.
19"
BASE PLATE THICKNESS PER MFG.
BP: B1 $ E1 (4)~3/4" DIA. J-BOLTS GR36
& W/ MIN. 12" EMBEDMENT
ELEV.=100'-0"ELEV.=100'-0"
PIER 5 PIER 5
8"
#5 X 10' LONG HAIRPINS, TYP.
4"
9" 9"
G1
EXISTING WALL
2"
2"
2"
#4 DOWELS @ 12" O.C.
4" EPOXY TO EX. CONCRETE WALL
SIMPSON SET-3G
4"
C1
1' - 4"
1' - 4"
EXISTING WALL
1' - 0"4"
1' - 10"
19"
B1
8"
B1
8 1/8"
8"
2"
#4 DOWELS @ 12" O.C.
4" EPOXY TO EX. CONCRETE WALL
SIMPSON SET-3G
BASE PLATE THICKNESS PER MFG.
BP: H1 (4)~1" DIA. Ø THREADED ROD F1554
GR36 W/ DOUBLE NUT ON END & W/ MIN. 12"
EMBEDMENT.
ELEV.=100'-0"ELEV.=100'-0"
H1 (MAIN FRAME)H1 (MAIN FRAME)
BASE PLATESBASE PLATES
1' - 0"
8"1' - 1 1/8"
GRID LINE A, B, C, D
BASE PLATE THICKNESS PER MFG.
(4)~3/4" DIA. J-BOLTS GR36 &
W/ MIN. 12" EMBEDMENT
ELEV.=100'-0"ELEV.=100'-0"
A1, B1, C1, D1, E1, F1A1, B1, C1, D1, E1, F1
BASE PLATE THICKNESS PER MFG.
G1 (4)~1" DIA. Ø THREADED ROD
F1554 GR36 W/ DOUBLE NUT ON END
& W/ MIN. 12" EMBEDMENT.
ELEV.=100'-0"ELEV.=100'-0"
G1 (MAIN FRAME)G1 (MAIN FRAME)
BL BL
BL BL
BL BL
8" 8 1/8"
8"
G1
A1
H1
1' - 0"
1' - 1 1/8" 1"
2" TYPICAL
(3) #4 VERTICALS
3'-0"x3'-0" CORNER
BARS SAME SIZE
AND SPACING AS
HORIZONTAL BARS
ONE LAYER OF REINFORCEMENT
2" TYPICAL
3'-0"x3'-0" CORNER
BARS SAME SIZE
AND SPACING AS
HORIZONTAL BARS
TWO LAYERS OF REINFORCEMENT
(3) #4 VERTICALS
REF. PLAN
WALL THICKNESS 't'
t/12
1/4
t/12
TYPICAL HORIZONTAL
AND VERTICAL WALL
REINFORCING REF. PLAN
NOTE: PROVIDE FND WALL CONTOL JOINTS @ 30' SPACING.
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
S110 S110
0924-25
11/11/25
SSR BASE PLATE DETAILS2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
NOT TO SCALE
FND WALL CORNERSFND WALL CORNERS4 4NOT TO SCALE
FND WALL CJFND WALL CJ6 6
REVISIONS NO. DATE
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
T.O. FTG. T.O. FTG.
96' - 0" 96' - 0"
B.O. FTG B.O. FTG
95' - 0" 95' - 0"
5
8" AGGREGATE BASE
1-1/2" RIGID INSULATION
6" CONCRETE SLAB
W.W.F 6x6-W2.1XW2.1
6 MIL VAPOR BARRIER, &
8" COMPACTED GRANULAR FILL
EXTERIOR
1/2" TITEN ANCHOR BOLT @ 48" O.C.
(4)~3/4" DIA. J-BOLTS GR36
& W/ MIN. 12" EMBEDMENT
BASE PLATE THICKNESS PER MFG.
(2) #5 BARS CONT, T&B
TOF: 96' - 0"TOF: 96' - 0"
FTG 2 FTG 2
4' - 0"
3"
1' - 7"
#5 BARS @ 12" O.C. , E.W.
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
T.O. FTG. T.O. FTG.
96' - 0" 96' - 0"
B.O. FTG B.O. FTG
95' - 0" 95' - 0"
D
1' - 4" 5' - 0"
BASE PLATE THICKNESS PER MFG.
G1 (4)~1" DIA. Ø THREADED ROD F1554 GR36 W/
DOUBLE NUT ON END & W/ MIN. 12" EMBEDMENT.
BASE PLATE THICKNESS PER MFG.
8" AGGREGATE BASE
6" CONCRETE SLAB
W.W.F 6x6-W2.1XW2.1
6 MIL VAPOR BARRIER, &
8" COMPACTED GRANULAR FILL
1'-6" X 1'-0" GRADE BEAM
W/ (4) # 6 TIE RODS WITH MECHANICAL SPLICES
EXTERIOR
1/2" TITEN ANCHOR BOLT @ 48" O.C.
TOF: 96' - 0"TOF: 96' - 0"
FTG 3 FTG 3
EX. WALL
#4 DOWELS @ 12" O.C.
EX. FTG
1' - 5 1/2"
#5 BARS @ 12" O.C. , E.W.
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
T.O. FTG. T.O. FTG.
96' - 0" 96' - 0"
B.O. FTG B.O. FTG
95' - 0" 95' - 0"
A
BASE PLATE THICKNESS PER MFG.
G1 (4)~1" DIA. Ø THREADED ROD F1554 GR36 W/
DOUBLE NUT ON END & W/ MIN. 12" EMBEDMENT.
BASE PLATE THICKNESS PER MFG.
8" AGGREGATE BASE1-1/2" RIGID INSULATION
6" CONCRETE SLAB
W.W.F 6x6-W2.1XW2.1
6 MIL VAPOR BARRIER, &
8" COMPACTED GRANULAR FILL
3"
1'-6" X 1'-0" GRADE BEAM
W/ (4) # 6 TIE RODS WITH MECHANICAL SPLICES
6' - 0"
EXTERIOR
1/2" TITEN ANCHOR BOLT @ 48" O.C.
6"
1' - 0"
TOF: 96' - 0"TOF: 96' - 0"
FTG 1 FTG 1
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
T.O. FTG. T.O. FTG.
96' - 0" 96' - 0"
B.O. FTG B.O. FTG
95' - 0" 95' - 0"
5
1-1/2" RIGID INSULATION BOARD
EXTEND TO FOOTING AS
INDICATED ON SECTIONS
TRACK
1' - 4"
8"
(2) #5 BARS, CONT.
8" FND WALL W/
(2) #5 BARS, CONT. T&B
REINFORCED CONCRETE
FOUNDATION WALL
8" FND WALL W/
(2) #5 BARS, CONT. T&B
#4 X 30" DOWELS @ 48" O.C.
6" CONCRETE SLAB
W.W.F 6x6-W2.1XW2.1
6 MIL VAPOR BARRIER, &
8" COMPACTED GRANULAR FILL
FIRST FLR. FIRST FLR.
100' - 0" 100' - 0"
T.O. FTG. T.O. FTG.
96' - 0" 96' - 0"
B.O. FTG B.O. FTG
95' - 0" 95' - 0"
5
REINFORCED CONCRETE
FOUNDATION WALL
6" CONCRETE SLAB
W.W.F 6x6-W2.1XW2.1
6 MIL VAPOR BARRIER, &
8" COMPACTED GRANULAR FILL
2 RIGID INSUL.
8" FND WALL W/
(2) #5 BARS, CONT. T&B
1/2" EXP JT W/ SEALANT
3/4"øx10" SMOOTH DOWEL @ 12" OC
LUBRICATE ONE END OR SET FIRST
PLACEMENT END IN APPROVED
PLASTIC INSERT
6" EXTERIOR CONCRETE APRON
6"
8"
1' - 4"
8"
OHD
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
1" = 1'-0"
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
S111 S111
0924-25
11/11/25
SSR FOUNDATION DETAILS2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
SCALE: 1/2" = 1'-0" on 11" x 17"
1" = 1'-0" on 22" x 34"
PIER 5 & FTG 2PIER 5 & FTG 2
3 3 SCALE: 1/2" = 1'-0" on 11" x 17"
1" = 1'-0" on 22" x 34"
PIER 2 & FTG 1PIER 2 & FTG 1
2 2
SCALE: 1/2" = 1'-0" on 11" x 17"
1" = 1'-0" on 22" x 34"
PIER 1 & FTG 1PIER 1 & FTG 1
1 1
#5 BARS @ 12" O.C. , E.W.
SCALE: 1/2" = 1'-0" on 11" x 17"
1" = 1'-0" on 22" x 34"
TYP. FND WALLTYP. FND WALL
4 4
SCALE: 1/2" = 1'-0" on 11" x 17"
1" = 1'-0" on 22" x 34"
FND WALL @ OHDFND WALL @ OHD
5 5
REVISIONS NO. DATE
DD
CC
BB
AA
1
1
2
2
3
3
4
4
5
5
PURLINS BY PEMB
5' - 0"
BY PEMB
5' - 0"
12' - 0" 30' - 0" 30' - 0" 28' - 0"
100' - 0"
30' - 0" 30' - 0" 30' - 0"
ROOF BRACING PER PEMB
THERMAL SPACER BLOCK
PANEL CLIP
STANDING SEAM ROOF PANEL
UNFACED FG INSULATION
2ND LAYER (R11)
UNFACED FG INSULATION
1ST LAYER (R25)
MTL JOIST OR PURLINS STEEL BANDING
LONGITUDINAL AND TRANSVERSE
MEMBRANE & VAPOR RETARDER
(CONCEALS PURLIN)
R25+R11 LINER SYSTEM ON METAL ROOF
U=0.031 PER ASHRAE 90.1, TABLE A2.3.3
SCALE: 1/16" = 1'-0" on 11" x 17"
1/8" = 1'-0" on 22" x 34"
ROOF FRAMING PLANROOF FRAMING PLAN
1 1
PLOT SCALE :
PROJECT NO:
SHEET # SHEET #
FILE NAME :
PLOT DATE :
PLOT BY :
BID DOCUMENTS
SHEET NAME:SHEET NAME:PROJECT: PROJECT:
7563 Driftless Rdg Wy
Verona, WI 53593 608-620-3036 (Office) ◦ svet@roussevengineering.com
ROUSSEV ROUSSEV
ENGINEERINGENGINEERING
SOLUTIONS, LLCSOLUTIONS, LLC
ADDRESS: ADDRESS:
3802 KIPP ST,
MADISON, WI 53718
As indicated
E:\Projects\2025\0924-25 UPI\REVIT\UPI-2025.rvt
S200 S200
0924-25
11/11/25
SSR ROOF FRAMING PLAN2025 BUILDING ADDITION
UPI MANUFACTURING
S87W35670
GODFREY LN
EAGLE, WI 53119
NOT TO SCALE
ROOF_SECTIONROOF_SECTION2 2
REVISIONS NO. DATE
STAFF REPORT AND RECOMMENDATION
SITE PLAN/PLAN OF OPERATION
Date: January 7, 2026
To: Planning and Zoning Commission and Town Board
Owner: Chapman Oil Inc, Robert Chapman (applicant)
Location: S90W35680 CTH NN, Tax Key No. EGLT 1818.999.003
Jurisdiction: This property is located entirely within the Town’s zoning jurisdiction.
Zoning Classification: B-4 Mixed Business.
Existing Use: Multi-tenant building (Citizen’s Bank, Country Kids) and parking lot.
Proposed Use: Site Plan, Plan of Operation review to construct a 3,200 SF building which will house a taxidermy
business (Northwoods Taxidermy)
Application(s): 2025-24 Site Plan/Plan of Operation - https://s.zoninghub.com/EF2T3PYVRM
Staff Analysis
The subject property is 2.7 acres in size, excluding the right-of-way of Godfrey Ln and is located on the northeast
corner of Godfrey Ln and CTH NN within the Town Business Park. The property was created via a Certified Survey
Map (CSM) in 1993. The property contains a 10,000 sf multi-tenant building which houses Citizen’s bank on the
west side of the building and Country Kids on the east side of the building. There is existing parking on both the
north and south sides of the building. The grassy area to the north of the building, adjacent to Godfrey Ln contains
an existing stormwater detention basin to handle the site stormwater.
The petitioners are proposing to construct a 3,200 sq. ft metal Cleary building which will house a taxidermy
business (Northwoods Taxidermy). The building will be located north of the existing multi-tenant building. The
building will be constructed of prefinished metal panels and will have decorative wainscotting on the south and
west face of the building, There is one (1) overhead door that will face Godfrey Ln. Hours of operation are typically 6
a.m. to 4 p.m. Monday through Friday with 4-5 employees working in the building at any given time. The stormwater
for the site is directed to the on-site stormwater facility along Godfrey Ln. The building and the proposed use meets
the requirements of the B-4 District, however, the Town Board will need to approve the overhead door that faces a
public street.
Staff Recommendation:
Staff recommends conditional approval of the Site Plan/Plan of Operation to construct the proposed addition on
the north side of the existing building subject to the following conditions:
1. The operator of the taxidermy business shall at all times maintain a n up-to-date taxidermy license with the
state Department of Natural Resources and U.S. Fish and Wildlife Service, as applicable.
2. The overhead door facing Godfrey Ln shall be removed or relocated, unless otherwise approved by the Town
Board.
Page 2
3. No taxidermy waste shall be buried on the subject property and no taxidermy waste shall be burned on the
subject property.
4. The Applicant shall apply to the Waukesha County Environmental Health Division (EHD) for approval of the
existing septic system, or obtain a Sanitary Permit for a new system, as applicable. Documentation shall be
provided that adequate septic facilities are provided for the proposed use, prior to issuance of the Zoning
Permit.
5. No changes to the site landscaping are proposed. A landscape plan shall be provided to ensure that the
building complies with Article 9 – Landscaping. All existing landscaping shall be maintained in perpetuity.
6. All construction shall comply with the building plans/site plan approved by the town.
7. Prior to any construction taking place, a Zoning Permit and Building Permit must be issued by the Town
Planner and Town Building Inspector.
8. Any outdoor storage shall be screened from the road and shall not create a nuisance for nearby property
owners or businesses. Outdoor storage shall be limited to one (1) pick-up truck and one (1) box trailer.
9. Any outdoor lighting shall be shielded so that light rays do not adversely affect adjacent uses .
10. All proposed signage, as applicable, shall be approved by the Building Inspector.
11. Prior to the issuance of the Zoning Permit, the Town Planner must be notified by the Town Engineer that the
development meets all provisions of the Storm Water Management Ordinance for the Town of Eagle.
12. Documentation shall be submitted to the Town Planner that the local Fire Inspector has inspected the
building for compliance with all local fire codes, prior to the issuance of an occupancy permit.
13. Documentation shall be submitted to the Town Planner that the Town Building Inspector has completed a
thorough inspection of the building for compliance with all building codes, prior to the issuance of an
occupancy permit. If state approved plans are required, a copy of said plans shall be submitted to the Town
Planner and Building Inspector for review and approval prior to the issuance of a Building Permit.
14. All activities on the subject property herein may not in any way become a nuisance by reason of
appearance, noise, dust, smoke, illumination, odor or any other similar factor.
15. An up-to-date Site Plan/Plan of Operation must be on file, at all times, with the Town of Eagle.
16. The Town reserve the right to review any condition imposed as part of the Conditional Use and/or Site
Plan/Plan of Operation if said use becomes a problem in the area. The Town Plan Commission may modify,
change, delete, add, etc. any conditions which they feel may be reasonable to allow this use and ensure it
does not become detrimental to the surrounding area.
17. Professional Fees. The petitioner shall, on demand, reimburse the Town of Eagle for all costs and expenses
of any type that the Town incurs in connection with this conditional use, including the cost of professional
services incurred by the Town (including engineering, legal, planning and other consulting fees) for the review
and preparation of required documents or attendance at meetings or other related professional services for
this application, as well as to enforce the conditions in this conditional ap proval due to a violation of these
conditions.
Page 3
18. Payment of Charges. Any unpaid bills owed to the Town of Eagle by the subject property owner or his or her
tenants, operators or occupants, or agents, for reimbursement of professional fees (as described above);
or for personal property taxes; or for real property taxes; or for licenses, permit fees or any other fees owed
to the Town; shall be placed upon the tax roll for the Subject Property if not paid within 30 days of the billing
by the Town, pursuant to Section 66.0627, Wisconsin Statutes. Such unpaid bills also constitute a breach
of the requirements of this conditional approval that is subject to all remedies available to the Town,
including possible cause for termination of the conditional approval.
Jacob Heermans
Town Planner
Attachments
Exhibit A – Site Plan
Exhibit B – Building Plans
N:\PRKANDLU\Planning and Zoning\Community Assistance\T EAGLE\STAFF REPORTS AND PROJECTS\2025\2025-24 Chapman SPPO\Staff Report Chapman.docx
Client Information
CHAPMAN, ROBERT
Email: Chapmansbpeaglr@gmail.com
Cell Phone: (262) 844-0185
UNKNOWN
EAGLE, WISCONSIN 53119
Location: N/A
S90W35680 COUNTY ROAD NN
EAGLE, WISCONSIN 53119
County: WAUKESHA
Tenant: N/A
Building Site Location:
Building Specification For:
Note: These colors are as close to the actual colors as permitted by printing. Actual metal samples must be reviewed with your Sales
Specialist. Colors vary depending upon position and angles.
South End Wall 1 on Building 1
Elevations for Building 1
P.O Box 930220
Phone: (608) 845-9700
Verona, WI 53593-0220
Fax: (608) 845-7070
CHAPMAN, ROBERT
12/22/2025
Doc ID: 9910120251222150927
Elevations & Floor Plan
v1.0
1 of 5
Note: These colors are as close to the actual colors as permitted by printing. Actual metal samples must be reviewed with your Sales
Specialist. Colors vary depending upon position and angles.
North End Wall 2 on Building 1
P.O Box 930220
Phone: (608) 845-9700
Verona, WI 53593-0220
Fax: (608) 845-7070
CHAPMAN, ROBERT
12/22/2025
Doc ID: 9910120251222150927
Elevations & Floor Plan
v1.0
2 of 5
Note: These colors are as close to the actual colors as permitted by printing. Actual metal samples must be reviewed with your Sales
Specialist. Colors vary depending upon position and angles.
West Side Wall 1 on Building 1
Note: These colors are as close to the actual colors as permitted by printing. Actual metal samples must be reviewed with your Sales
Specialist. Colors vary depending upon position and angles.
East Side Wall 2 on Building 1
P.O Box 930220
Phone: (608) 845-9700
Verona, WI 53593-0220
Fax: (608) 845-7070
CHAPMAN, ROBERT
12/22/2025
Doc ID: 9910120251222150927
Elevations & Floor Plan
v1.0
3 of 5
Floor Plan
P.O Box 930220
Phone: (608) 845-9700
Verona, WI 53593-0220
Fax: (608) 845-7070
CHAPMAN, ROBERT
12/22/2025
Doc ID: 9910120251222150927
Elevations & Floor Plan
v1.0
4 of 5
"D" = Bottom elevation (B.E.) of overhead door:
0' 4"
The bottom of all overhead doors (top of finished floor) are
recommended to be placed at 4" above the 100'-0" mark (100'-4"). In
building without paved floors, B.E. of doors may be lower - e.g. 100'-
0".
10' 0"
"E" = Height of overhead door:
1' 7"
"F" = Available headroom:
Overhead door height = the height of the overhead door being placed
in this building.
Available headroom = the space available for overhead door tracks
and openers. If a ceiling is installed, headroom will be reduced by
about 1". Door headroom requirements must be confirmed with the
door supplier.
Headroom calculation formula:
("B") - ("D") - ("E") = ("F")
(Truss Clearance) - (B.E. of overhead door) - (Overhead door height) =
(Available headroom)
Example:
(10'-0") - (4") - (8'-0") = (1'-8" of available headroom)
Roof Pitch:
Roof Peak Height:
"A" = Actual Eave Height:
"B"=Clearance from finished floor to bottom of truss:
3.5/12
20' 11 1/2"
13' 8"
11' 8"
Interior Clearances:
Exterior Heights:
(Clearance is reduced by the thickness of any ceiling and the thickness of
any floor covering)
Top of concrete floor must be at 100'+4" for this
foundation type. If thicker concrete floor is
desired, the extra thickness will be below the
100'+0" mark.
Building 1
Interior Clearances and Exterior Heights
Overhead Frameout & Headroom
P.O Box 930220
Phone: (608) 845-9700
Verona, WI 53593-0220
Fax: (608) 845-7070
CHAPMAN, ROBERT
12/22/2025
Doc ID: 9910120251222150927
Elevations & Floor Plan
v1.0
5 of 5
Date: January 7, 2025
To: Town of Eagle Plan Commission
From: Jacob Heermans, Town Planner
Subject: Review of the number of accessory buildings allowed on a property at W377S10480 Betts Rd
which is within the County’s Shoreland Jurisdiction. Tax Key 1858.999.005. Doug and Linda
Varrelmann (owners)
Application: 2025-26; https://s.zoninghub.com/EDOCLD17D5
The petitioners own a 4.6-acre parcel on Betts Rd which is entirely within the County’s Shoreland
jurisdiction and is zoned A-2 Rural Home District. The property contains a single-family residence with
an attached garage, an above ground swimming pool, and a 36’ x 63’ pole barn. There is a deck on the
south side of the home which contains a gazebo, approximately 150 sf in size. The County Shoreland
Protection Ordinance defines the gazebo as a structure which is subject to the maximum accessory
building provisions. Properties with the County’s jurisdiction are generally limited to two (2) accessory
buildings unless the Town Plan Commission renders a finding to allow more than two (2) accessory
structures.
The petitioners are proposing to construct a 10’ x 16’ shed for personal storage in addition to the
existing accessory buildings and are seeking Plan Commission approval for a total of three (3) accessory
structures. The structures meet the 2% limitation, as required by the County and meet all locational
requirements. Residential properties within the Town’s jurisdiction are generally allowed a total of
three (3) accessory buildings (two plus a minor shed less than 150 sf in size). The shed is proposed to be
constructed south of the above ground pool, north of the existing tree line. The shed will largely be
screened from neighboring properties and from the road.
Potential Plan Commission motion: It is recommended that the Planning and Zoning Commission
approve of the request for a third accessory building. The person making this motion should refer to the
application and any additional information as discussed by the Plan Commission. The analysis as noted
in the staff report may also be used as the justification, in which the Plan Commission may, or may not,
expand upon based on the discussion.
Enclosure: Exhibit A – Zoning Permit Application Packet
N:\PRKANDLU\Planning and Zoning\Community Assistance\T EAGLE\STAFF REPORTS AND PROJECTS\2025\2025-26 Varrelmann\Varrelmann Accessory Building Review.docx
Page 1 of 5
PENDING EAGLE ZONING VIOLATIONS
TOWN AND COUNTY VIOLATIONS
This list is for informational purposes only and no discussion or action will be taken on these
matters. Italics indicates new information since last update.
TOWN VIOLATIONS
Tom Reynolds, S70W35196 TOWNSHIP ROAD X
8/21/24: RL conducted site visit from the road. Met with CM and SJ to discuss the history of the property
and next steps. It was identified that the building permit had expired. Violations appear to include, at a
minimum, business without permits (commercial greenhouse/food processing), disrepair of building
(greenhouse) and expired permits. SJ stated that he will try to make contact with the owner first.
9/24/24: It was relayed to RL that at least two attempts have been made by SJ to contact the owner by site
inspection. RL will consult with Town Atty to discuss next steps.
11/7/24: Met SJ and owner on property. Owner gave a tour and explained the farming operation (Alchemy
Acres). it runs like a co-op where people come and pick up their order or they will deliver it. It's all local
people. He grows and sells, fresh produce and modifies some of it by fermenting it. He creates dried herbs
and juices produce. He does not participate in any markets. He does not sell mead and understood he was
denied that permit. He does have agricultural equipment lying around the property (soil steamer, pallets,
wheelbarrows). He was in the middle of siding the addition and there were construction materials that
needed to be cleaned up. Has chickens and 4 hoop houses near the house, + approximately 10 hoop houses
out in the field. He is there on T/R/S and some Sundays. Typically, no one there on M/W/F. When asked
about mowing around the fields, he indicated that it would disrupt the habitat of inspects that would turn to
feeding on the crops. Chickens on site. Was willing to put up vegetative screening around the property
near the roads but wants to make sure it's beneficial to his operation. The property is currently being
transferred to an LLC where it will be employee-owned.
11/21/24 RL spoke with WC Environmental Health Division (EHD). They are trying to contact the owner
to better understand what types of products are being made. No licensing has been given. RL needs to
review ordinance and provide owner with what options might be available. May need to involved Town
Atty.
1/10/25 Reviewed zoning code for possible options for owner. Can apply for a Greenhouse CU and can
continue to grow produce on site. However, there does not appear to be a path in the code to support
accessory agricultural uses such a production of teas, juices, herbs, etc. Junk, debris, general yard property
maintenance must be explored by the Building Inspector.
1/27/2025 RL has received information from EHD that they do not appear to have enough proof to post a
Cease and Desist order, but will be sending a letter reminding property owner of proper permitting. RL
and EHD are drafting separate letters regarding the applicable violations to achieve voluntary compliance.
2/21/25 No update.
Early March 2025: Environmental Health Division send letter to property owner notifying him that food
processing without proper food grade protection or proper state and local licensing is a violation of state
codes.
4/7/25 Planner notified of someone living in a camper on site.
4/16/25 Planner drove by property. Camper had been removed. Some building materials removed.
Approximately 20 greenhouses present.
6/6/25 Letter with attachment of code references and application sent to property owner via mail and
email, requesting the property be brought into compliance with town ordinances, including the property
maintenance code and the zoning code. Applications were requested by July 1 and permission to re-inspect
the property was requested to be granted by June 25, 2025.
6/26/25 Staff received an email from the property owner regarding the letter noted above.
10/23/25 Staff met with Mr. Reynold’s on his Road X property, but was not given permission to inspect.
Inspected property from the driveway, ROW, and neighboring property and observed sheep.
11/5/25 Joint meeting held at the Town Hall to discuss the violation with Mr. Reynolds and to hear
neighbor concerns.
11/17/25 Town BI inspected Mr. Reynold’s property. Structure which lacks an active Building Permit has
been improved, however, no progress has been made on the remainder of the property/violations.
Page 2 of 5
11/19/25 Conference call with Planner, Town Chair and Waukesha County Planning Manager to discuss
strategy. Planner will send a letter prior to end of the week clearly outlining the violations and
establishing a short window in which to gain compliance. Failure to do so will result in citations and
likely a lawsuit.
12/8/25 Violation letter drafted. Staff is seeking input from Environmental Health on additional
violations.
12/15/25 Meeting with Waukesha County Environmental Health staff to discuss violation and possible
health code violations.
12/18/25 A violation letter was sent to the property owner establishing a January 5, 2026, deadline for
compliance. (Pending, JH)
COUNTY VIOLATIONS
Jeffrey and Heather Sorenson, W345 S10503 CTH E
Constructed a fence within the shore setback area
10/28/24 Complaint received about a fence that had been constructed around the property within the shore
setback area.
11/19/24 Need to contact property owner(s) to schedule a site inspection.
12/10/24 Contacted owners to schedule an inspection.
1/28/25 No response from owners. Need to follow up to schedule inspection and/or require removal.
02/07/25 Violation reassigned to AT. Request to Inspect letter sent 02/10/25.
02/18/25 Owner (Heather Sorensen) called AT and stated fence was placed as a way to prevent neighbor's
dog from crossing into property (dog had previously bit their child). Wants to know what can be done to
keep the fence. Other neighbors are their cousins and they love having the fence. Was not aware a fence
required a permit. AT will conduct site visit on 02/25/25.
02/25/25 Site visit showed white fence along southern lot line. Property also had sections of black metal
"decorative" fencing (mostly along the southeast property line near retaining wall), more panels of this
fencing are stacked off to one side. Tall black fence along SW corner of home (not permitted in the 2021
addition ZP). Currently reviewing the approved landscaping plan to confirm compliance with replanting
requirements.. Will need to send follow up letter.
04/10/25 Violation compliance letter sent. Deadline to remove all fencing w/in 75 feet of shore is May
22nd. Will need to conduct site visit after deadline to confirm continued compliance.
05/27/25 Site visit scheduled for 05/29/25
06/09/25 Neighbor emailed POD that owner has told other residents that he is not going to take the fence
down because it is for his children's safety. He started to do the removal and then stopped and plans to put
it back up. “Is safety a reason he can put the fence back up?" I informed neighbor that I will be onsite this
week and if they put the fence back up after my visit, she should contact me.
06/11/25 Site visit showed panels have been removed from fence along lot line (panels are laying in a pile
along the shore) but posts are still present. Tall black fence by SW corner of house is still present. Owner
would like to keep this fence and some black fencing along the steep retaining walls as his son is autistic
and doesn't have any safety awareness so they are concerned he would fall down the steep retaining walls.
06/11/25 Spoke with supervisors. Will conduct another site visit to ensure the posts have been removed
and will advise owner that a variance is needed to retain the black fencing near the retaining walls since it
is within 75' of the OHWM.
06/30/25 Neighbor emailed photos. Stated that "The plan for the neighbors appears to be that they will
leave in the posts and lean the fencing against it. I'm guessing they feel it is then no longer a permanent
structure and rules don't apply to it. He has recently installed solar lights on the top of each post, so I
assume he is keeping them in long term. It both looks horrible, and has to be a technicality for leaving it
in place. I can try to take more pictures if you need them. It is difficult to see how he has leaned the
fencing slats against the post, but easy to see in person. "
07/10/25 Compliance letter sent. They will have until July 25th to remove remaining post and fencing or
will need to apply for a variance by that deadline to keep any of the fencing (even around the retaining
walls)
07/21/25 Spoke w/ Jeff Sorensen as he left a call w/ POD that he wanted to talk with me. I told him I can
email the variance application. Said that he would need to provide proof of hardship that is not personal in
Page 3 of 5
nature. He said that of course this is personal and that he's trying to keep his kids safe. I gave him an
example that say you had more kids than the number of bedrooms available that is a personal
consideration. He understood what I meant but was not happy about it. Emailed his wife the application
and reminded them of the July 25th deadline to apply by.
07/28/25 No application for variance received on or before July 25th. Will conduct site visit to find out if
fencing is still present.
08/04/25 Called owner, they said application was coming via certified mail.
08/07/25 Application arrived, AT received application and routed to admin for processing.
11/20/25 Variance went before County BOA in October. Requested tabled, as owners were not in
attendance and neighbor raised concerns which need to be addressed by the owners. BOA likely to take
action at the January meeting.
12/22/25 Item will be on the January BOA agenda for action. (Pending, AT)
Rachel and Jeff Schaefer, S101W34695 CTH LO;
Junk, work w/o permits, structure in disrepair
8/5/2021: Received complaint regarding junk, work without permits and residence/fence in disrepair. After
multiple attempts, our office was unable to inspect the property.
Summer 2023: Owner contacted the office in summer of 2023 for a zoning permit. Our office 10/23/23:
County sent a letter that stated the following: Listing photos revealed miscellaneous junk was present and
viewable to the present. Owner was made aware of the active violation on the property. He granted our
office permission to inspect over the phone.
6/2/23: A site inspection was conducted, revealing land altering activities with new basement
construction. In addition, multiple items regulated as junk including an unlicensed boat, inoperable boat
trailer, broken hot tub, construction materials, buckets and other miscellaneous items were observed. The
owners had deadlines of 6/23/23 to submit a zoning permit application and 7/10/23 to remove junk from
the property.
10/16/23: Another site inspection was conducted which revealed little progress had been made and a
majority of the junk and miscellaneous materials remained on-site and visible. No zoning permit
application had been received at that time either. Deadlines of 11/6/23 and 11/27/23 were given to apply
for a ZP and remove the junk-type items, respectively. Note: the staff person involved soon after left the
county and the violation was reassigned.
April 2024: Citations were issued 5/6/24. The owner was scheduled a court date of 6/5/24 and failed to
show. Corp Counsel stated that she waits a month and if the owners do not contact them to reopen the
case, it is closed out after a month. Corp Counsel suggested that a follow-up letter be written.
9/26/24 Staff working with Corp Counsel to get clarity on next steps.
11/15/24 A violation letter was sent to the subject property on 11/15/24. It appears a previous employee
was able to contact the owner using that address (I have been using the mailing address on file with tax
listing). The owner was given a deadline of 12/2/24 to submit a zoning permit and minor grading permit
application and remove junk-type items from the property. No further extensions will be granted;
additional citations will be immediately issued if the permits are not applied for and/or the property is not
in compliance with the Ordinance.
12/4/24 Owner applied and paid for an ATF zoning permit for the replacement/repair of the residence’s
foundation. There is a discrepancy between the survey we have on file and GIS. It appears some of the
lots in this subdivision were redescribed in 1978 (?). Tax listing is looking into the discrepancy and we
have not heard back.
1/27/25 Emailed Tax Listing for a second time to obtain information on the right of way discrepancy.
Another attempt with be made. KSF
3/30/25: Emailed tax listing for a third time to obtain information on the right of way discrepancy. No
response.
4/1/25 Called owner and left a voicemail stating that I would conduct a site inspection in the near future.
4/10/25 Conducted site inspection which revealed miscellaneous junk and construction materials were still
present on the property in addition to a vehicle that is not registered. Items that were present include:
buckets, bricks, miscellaneous wooden items, ladders, a cement mixer, a trailer, tree stumps, a refrigerator,
plywood, a fish tank, and a large pile of decorative stones. I did not walk the entire property.
4/11/25 A violation letter was sent, with a deadline of 5/30 to bring property into compliance.
Page 4 of 5
4/22/25 Received call from owner stating the tires have been placed on the trailer and he will need to call a
junk removal company for the refrigerator. The septic system was pumped on 4/18 and the PSE was
issued.
4/24/25 Zoning Permit E24:019 was issued and a new deadline of 6/30 was granted to remove the
remaining items.
5/28/25 The owner has until 6/30 to remove the remaining items (junk, construction materials, etc.). A
site inspection will be conducted on or shortly after that deadline.
6/20/25 No update as deadline is still pending.
7/28/25 Site inspection conducted, which revealed minimal progress. The refrigerator is gone and all the
vehicles are registered. The deadline to complete the basement and remove the construction materials is
October 24. The owner stated he would start getting rid of junk items on and near back porch.
11/20/25 Jeff called a couple weeks ago and staff has been playing phone tag. Staff will try to contact him
again and schedule a site inspection.
12/26/25 No update; staff will attempt to contact owner. (Pending, KS)
Bernard and Clara Erdmann, W345S10433 WAMBOLD RD
Construction/remodel of structure located within floodplain and not conforming to offset.
6/3/25 Complaint received about construction/remodel of structure located within floodplain and not
conforming to offset.
06/14/25 Violation reassigned from Ken Smith to Anna Tuinstra.
6/20/2025 Violation letter mailed.
06/27/25 Daughter of owner called. Said their dad (the owner) had extended the roof line in 2017 and also
added boards to the back for their pontoon boat to be protected. This past year their nephews put boards on
the sides of it to protect it from leaves. There is also a fence along the back wall (SW side) that "may or
may not be on the lot line". Their neighbor had given them a "warning" that any further improvements to
the structure she would report it as a violation because they did not have any permits and the structure is in
the floodplain. They describe the structure as a "boat shelter". They are willing to comply with our
requirements. Depending on the improvements an ATF ZP may be needed.
07/16/25 Site visit w/ EG and son of homeowner. Said the fence used to be wire and the neighbor's tree
fell on it. They replaced the fence with wood instead of the wire because the wood fence blocks the leaves
from coming into the boat storage area. The "carport"/boat storage area has strange internal retaining walls
that apparently the owner cut away some of the space to make it more level? The fencing does fit better
with the adjacent buildings than the existing wire fence. The neighbor has been cleaning up her property
so the white fence is possibly more visible to them compared to the wire fence but it all has been existing
on the property since maybe the 80s?
07/21/25 Discussed VL w/ JH. We need proof that the overhang and walls of the "boat shelter" have been
present for more than 10 years. Otherwise they will need to remove it or apply for ATF variance.
08/15/25 Deadline to remove is moved to September 15th as owner of property is in the hospital.
11/20/25 Structure has been removed, per violator. Need to verify via site visit.
12/26/25 Inspection still needs to be completed, as assigned staff has been out on medical leave. Plan to
inspect in early January for compliance. (Pending, AT)
Steve Wruck, W345 S10483 CTH E
Storgage of construction equipment, business materials and a junk boat
12/5/25 Complaint received with photos showing construction equipment.
12/26/25 Violation letter sent to property owner. (Pending, EG)
NOTES:
This list of zoning violations in the Town of Eagle are pending with the Town of Eagle and/or with
Waukesha County PZD. The list is provided to the Town each month at the request of the Town Plan
Commission.
Page 5 of 5
N:\PRKANDLU\Planning and Zoning \Community Assistance \T EAGLE \Violations\TOWN OF EAGLE ZONING VIOLATIONS
PENDING WITH WC AND TOWN.docx Revised 12/26/25 JH
Source: Town of Eagle website. First collected Oct 20, 2026.