NOTICE OF PUBLIC HEARING
PROPOSED PRELIMINARY PLAT OF [Subdivision Name]
PLEASE TAKE NOTICE that the City of Oconto Falls Planning Commission will hold a public
hearing on Tuesday 10th February, at 5:00PM, at the Oconto Falls Municipal Building, 500 N
Chestnut Ave., Oconto Falls, WI] regarding the preliminary plat of the "Former Washington
Middle School submitted by Kevin Birr, Birr Investments, LLC.
SUBJECT MATTER:
The proposal involves the division of approximately 2.8065 acres of land into 14 single-
family residential lots. The proposed plat is located at 102 S Washington Street,
Legal Description: All of Block 1 Volk’s 2nd Addition to Volk’s Plat and proposed
discontinued ally, being part of the Southwest ¼ of the Southeast ¼ and part of the
Northeast ¼ of the Southeast ¼, all in Section 23, Township 28 North, Range 19 East
Village of Oconto Falls, Oconto County, Wisconsin.
The proposed preliminary plat is on file for public inspection at the City of Oconto Falls
Clerk’s office and online at https://cityofocontofalls.com/government/city-council/current-
meeting-agendas/
PROPERTY LOCATION/PARCEL NO(S): Tax Parcel Numbers 2660708316419
PUBLIC PARTICIPATION:
All interested persons, or their agents, are invited to attend the public hearing and be heard
regarding this proposed preliminary plat. Written comments may be submitted to the Clerk
prior to the meeting and will be incorporated into the record.
Dated this 19
th of January 2026
Peter Wills
Administrator/ Clerk-Treasurer
City of Oconto Falls
N WASHINGTON ST
CEDAR AVE
UNION AVE
JEFFERSON STE CENTRAL AVE
S ADAMS ST
S WASHINGTON ST
ArcGIS Web Map
Sanitary - Manhole
Sanitary - Gravity Main
8"
15"
Water - Curb Box
Water - Main Valve
Water - Water Main
4"
6"
8"
12"
Oconto_Co_2022.sid
Red: Band_1
Green: Band_2
Blue: Band_3
12/5/2025, 9:16:52 AM
0 0.02 0.040.01 mi
0 0.03 0.060.01 km
1:1,140
Planning Commission Public Hearing August 12,2025 1
CITY OF OCONTO FALLS
PLANNING COMMISSION MEETING
PUBLIC HEARING
Council Chambers – Municipal Building
500 N. Chestnut Avenue
Oconto Falls, WI 54154
TUESDAY AUGUST 12, 2025 – 5:00 PM
MINUTES
Chairman Coopman called the meeting to order at 5:00 PM.
Roll Call
Present: Marty Coopman, William Zietlow, Chique Tousey-Tabar, Jeff McDonald, Judy
Kostreva and Brad Rice
Also Present: Mayor Clint Braun, City Administrator Peter Wills, Deputy Clerk Jenny Friedman,
Michelle Tester, Aaron Trempe, Cary Lerquin, Tamy Hintz, Dave Alsteen,
Susan Mogged, Stuart Russ
******PUBLIC HEARING****
*** Public Hearing for investigation and determination of the Town of Stiles
Petition to Annex portion of County I from City boundary south of South Main
Street north to the northside of Columbia Street ****
Public Hearing Notice was properly posted and published in the Oconto County Times
Herald newspaper for two consecutive weeks. Property owners within a 200 ft. radius were
also given proper notification ****
DISCUSSION AND POSSIBLE RECOMMENDATION/ACTION ON THE
FOLLOWING:
4. Town of Stiles Petition to Annex portion of County I from City boundary south of
South Main Street north to the northside of Columbia Street
At 5:00pm Chairman Coopman opened the floor for public comments for Public
Hearing for investigation and determination of the Town of Stiles Petition to
Annex portion of County I from City boundary south of South Main Street north
to the northside of Columbia Street. Deputy Clerk Friedman and City
Administrator Wills verified there were no written in or called in concerns prior to
the Public Hearing. There was one letter returned in the mail. Deputy Clerk
Friedman explained that address was double check with the county website but
was the same address on file.
First Call at 5:04pm concerns that were brought up from the public were;
• Right now, the speed limit is 45mph. What will it go down to?
35mph the road but the school zone would like it to be 25mph.
Planning Commission Public Hearing August 12,2025 2
• How long will it take to get the speed limit down? -Sixty to ninety days.
• Will there be a digital speed sign? – Yes, the one from the old middle
school will get moved over to new middle school.
• Will the people in this annexation area get their addresses changed? –
There is no intent to change their addresses because they are not coming
into the city.
• Just County I is getting annexed? - County I and the right away.
• If the road needs to be fixed who will be responsible for this? This is
something that still needs to be determined.
Second call for public input was asked at 5:14 pm by Chairman Coopman. Chairman
Coopman asked if there were any more concerns and comments on Public Hearing for
investigation and determination of the Town of Stiles Petition to Annex portion of
County I from City boundary south of South Main Street north to the northside of
Columbia Street. Oconto Falls School Superintendent Stuart Russ thanked the City of
Oconto Falls for trying to lower the speed limit in this area.
Third call for public input was asked at 5:22 pm by Chairman Coopman. Chairman
Coopman asked if there were any more concerns and comments on Public Hearing for
investigation and determination of the Town of Stiles Petition to Annex portion of
County I from City boundary south of South Main Street north to the northside of
Columbia Street. There were no other citizens concerns.
A. Close Public Hearing
With no other concerns from the public on the Public Hearing for investigation
and determination of the Town of Stiles Petition to Annex portion of County I
from City boundary south of South Main Street north to the northside of
Columbia Street. Chairman Coopman closed the public hearing at 5:22pm.
B. Committee recommendation to City Council.
MOTION: MC DONALD/RICE
Motion to recommend the Town of Stiles Petition to Annex portion of County I
from City boundary south of South Main Street north to the northside of Columbia
Street to the Common Council
Voice Vote: All present voting aye - MOTION CARRIED
5. Update Discuss Amending 2008 Comprehensive Plan Maps
a. Review motion Amending 2008 Comprehensive Plan Maps
MOTION: Tousey-Tabar/Kostreva
Motion to Rescind the previous made on August 5,2025 of Motion to amend 2008
Comprehensive Plan Maps territory owned by OEC with in thirty-two acres
Planning Commission Public Hearing August 12,2025 3
between Splinter Creek and North Chestnut to amend planned use industrial to
residential.
Voice Vote: All present voting aye - MOTION CARRIED
MOTION: Tousey-Tabar/Kostreva
Motion to amend 2008 Comprehensive Plan Maps territory owned by current
property owners with in thirty-two acres between Splinter Creek and North
Chestnut to amend future planned use industrial to residential.
Voice Vote: All present voting aye - MOTION CARRIED
NEW BUSSINESS
6. Approve Planning Commission Minutes from 05.29.2025, 08.05.2025
MOTION: Mc Donald/Rice
Motion to approve Planning Commission Minutes from 05.29.2025, 08.05.2025
Voice Vote: All present voting aye - MOTION CARRIED
7. Home Owned Business Zoning- Conditional Use Permit process
Review current ORD 480-6 Single Family (R-1) & Multiple Family Residence
NO ACTION TAKEN
A. Review current ORD 480-14 to 480-20 Conditional Use
The current ORD 480-14 to 480-20 Conditional Use is vague should be updated
to better guide citizens with in the city.
B. Current City of Oconto Falls Conditional Use Permit Application, Public Notice,
& State Statue 62.23(7)(de) Conditional Use Permits
MOTION: Rice/ Zietlow
Motion to direct the City Administrator to develop new conditional use
application and amend Ordinance 480.21 regarding conditional use and home
occupations.
Voice Vote: All present voting aye - MOTION CARRIED
C. Community example Conditional Use Permits
NO ACTION TAKEN
D. Committee recommendations
NO ACTION TAKEN
8. Adjournment
Having no further discussion, Chairman Coopman declared the meeting adjourned
at 5:55 PM.
Planning Commission Public Hearing August 12,2025 4
______________________________
City Administrator Peter Wills
A quorum of the Common Council was not in attendance of this meeting
Planning Commission Public Hearing September 9,2025 1
CITY OF OCONTO FALLS
PLANNING COMMISSION MEETING
PUBLIC HEARING
Council Chambers – Municipal Building
500 N. Chestnut Avenue
Oconto Falls, WI 54154
TUESDAY SEPTEMBER 9, 2025 – 5:00 PM
MINUTES
Chairman Coopman called the meeting to order at 5:00 PM.
Roll Call
Present: Marty Coopman, William Zietlow, Chique Tousey-Tabar, Jeff McDonald, Judy
Kostreva and Brad Rice
Also Present: Mayor Clint Braun, City Administrator Peter Wills, Deputy Clerk Jenny Friedman,
Michelle Tester, Mathew McDermid
******PUBLIC HEARING****
*** Public Hearing for amending the City of Oconto Falls 2008 Comprehensive
Plan Maps page 62 to change parcel future use from industrial to residential.
A. Open Public Hearing
B. Receive Public Comments/Input
C. Close Public Hearing
At 5:00pm Chairman Coopman opened the floor for public comments for Public Hearing for
investigation and determination Public Hearing for amending the City of Oconto Falls 2008
Comprehensive Plan Maps page 62 to change parcel future use from industrial to residential.
Deputy Clerk Friedman and City Administrator Wills verified there were no written in or called
in concerns prior to the Public Hearing.
First Call at 5:00pm by Chairman Coopman for public input. There were no concerns from the
public.
Second Call at 5:35pm by Chairman Coopman for public input. There were no concerns from the
public.
Third Call at 5:36 pm by Chairman Coopman for public input. There were no concerns from the
public.
With no concerns from the public Chairman Coopman closed the public hearing at 5:38pm.
DISCUSSION AND POSSIBLE RECOMMENDATION/ACTION ON THE
FOLLOWING:
Planning Commission Public Hearing September 9,2025 2
4. Amending the City of Oconto Falls 2008 Comprehensive Plan Map page 62
update project area future use from industrial to residential.
A. Resolution No 25-007 PLANNNING COMMISSION ADOPTION OF THE
CITY OF OCONTO FALLS COMPREHENSIVE PLAN 2008 –
AMENDMENT ONE
MOTION: Rice/Zietlow
Motion to send resolution No 25-007 Planning Commission adoption of the City
of Oconto Falls comprehensive plan 2008 – amendment one.
Voice Vote: All present voting aye - MOTION CARRIED
NEW BUSSINESS
5. Approve Planning Commission Minutes from 08.12.2025
The minutes were not in the packet to be reviewed so they will be placed on the
next agenda.
NO ACTION TAKEN
Old Business
6. None for this meeting
New Business
7. Adjournment
Having no further discussion, Chairman Coopman declared the meeting adjourned
at 5:40 PM.
______________________________
City Administrator Peter Wills
A quorum of the Common Council was in attendance of this meeting
DESIGNER:
DrexelTeam.com
BID PLAN -FOR BIDDING PURPOSES ONLY
1
2
3
4
5
6
7
8
9
SCALE:
SHEET NO:
PROJECT NO:
COPYRIGHT DREXEL BUILDING SUPPLY IT IS
UNLAWFUL FOR ANYONE TO USE OR
REPRODUCE BY ANY MEANS ALL OR ANY
PORTION OF THESE DOCUMENTS WITHOUT THE
EXPRESSED WRITTEN PERMISSION OF DREXEL
BUILDING SUPPLY INC. DREXEL BUILDING
SUPPLY INC. RESERVES THE RIGHT TO USE ALL
OR PARTS OF THESE PLANS IN THE FUTURE.
ALTHOUGH EVERY EFFORT WILL BE MADE BY
DREXEL IN DESIGNING AND PREPARING THESE
PLANS AND CHECKING THEM FOR ACCURACY,
THE OWNER/GENERAL CONTRACTOR ASSUMES
ALL RESPONSIBILITY TO CHECK ALL DETAILS AND
DIMENSIONS, AND IS RESPONSIBLE FOR ANY
CHANGES OR ADJUSTMENTS REQUIRED DURING
CONSTRUCTION. DREXEL MAKES NO
REPRESENTATION FOR OR IMPLIES ACCURACY.
1/4" = 1'-0"SPRING SPEC
ADDRESS TBD BIRR INVESTMENTS
M. THOR
R23-136-W
A1
COPYRIGHT © 2023BID PLAN02/23/2023 MCT
REVISION03/02/2023 LJU
REVISED BID PLAN09/22/2025 LML
REVISED BID PLAN #2 10/07/2025 LML
GARAGE FLOOR AREA 502 SF
COVERED PATIO 94 SF
COVERED STOOP 38 SF
FIRST FLOOR AREA 1431 SF
TOTAL AREA 1431 SF
1/4" = 1'-0"
FRONT ELEVATION
1/4" = 1'-0"
LEFT ELEVATION
1/4" = 1'-0"
RIGHT ELEVATION
1/4" = 1'-0"
REAR ELEVATION
DN
FOUNDATION INFORMATION
• HOUSE FOUNDATION
• GARAGE FOUNDATION
• PORCH/PATIO FOUNDATION (UNEXCAVATED)
• WALL THICKNESS FOR REPRESENTATION ONLY-
MASON/CONTRACTOR TO VERIFY
• FINAL WALL/POST FOOTING SIZE AND DEPTH
DETERMINED BY CONTRACTOR
• MASON TO LOCATE PILASTERS AND SIZE FOOTINGS PER
CODE AND SOIL CONDITIONS
• WINDOWS/DOORS TO BE SET IN CONCRETE WALL- MAKE
R.O. 3” BIGGER IN WIDTH AND HEIGHT
• BEARING WALLS TO SIT ON MIN. 16” X 8”CONT.
CONCRETE FOOTINGS, STUDS @ 16” O.C.
WALL INFORMATION
• HOUSE EXTERIOR
• HOUSE INTERIOR
• GARAGE
FLOOR SYSTEMS
• BASEMENT
• FIRST FLOOR
• STANDARD LOADING (PER SQ. FT.)
40# LL. 15# DL.
• ADDITIONAL LOADING (PER SQ. FT.) (WHEN APPLICABLE)
•
• DURATION OF LOAD: 1.00%
ROOF SYSTEMS
• .
HEADERS
• STANDARD HEADER
ALL HEADERS NOT LABELED AS LVL TO BE MIN.
(2) 2X10 HEADER FOR ON-SITE (UNLESS VALUE
ENGINEERED FOR OFF-SITE CONSTRUCTION)
• TOP OF WINDOW R.O.S.
• MINIMUM OF (2) SHOULDER STUDS AT EACH END
FOR ALL OPENINGS 6’-0” AND LARGER
GENERAL INFORMATION
• ALL DIMENSIONS ARE TO THE ROUGH STUD (UNLESS
NOTED OTHERWISE)
2X6 WALLS=5 ½”, 2X4 WALLS =3 ½”
• ALL DIMENSIONS ARE TO OUTSIDE OF FOUNDATION
WALLS/BRICK LEDGES
• GENERAL CONTRACTOR TO LOCATE THE FOLLOWING
ITEMS IN THE FOUNDATION (WHEN APPLICABLE)
FLOOR DRAINS, ELECTRIC SERVICES, WATER HEATER,
SUMP PIT + PUMP, FURNACE, GAS/LP LINE, BASEMENT,
WINDOWS,ETC.
• ACTUAL STEPS IN FOUNDATION WALLS AND LOCATION OF
WINDOW WELLS TO BE DETERMINED ON-SITE BY GENERAL
CONTRACTOR
• DECK FRAMING SPECIFICATION TO MEET OR EXCEED
REQUIREMENTS DEFINED WITHIN "APPENDIX B" OF THE WI
UNIFORM DWELLING
• ALL CABINET LAYOUTS ARE CONCEPTUAL-CONSULT
CABINET DESIGNER FOR EXACT SIZES AND LOCATIONS OF
CABINETS, APPLIANCES, AND WINDOWS
• ALL DOOR HEIGHTS ARE 6'-8" UNLESS NOTED/SHOWN
OTHERWISE
• STUDS @
10# DL. FOR TILE FLOOR
13# DL. FOR GYPCRETE.(1.5" THICK)
20# DL. FOR FIREPLACE FACE/HEARTH
25# DL. FOR GRANITE/QUARTZ
DESIGNED FOR: ZONE 2
• STD. LOADING (PER SQ. FT.)
30# TCLL, 10# TCDL, 10# BCDL
• DEFLECTION: LL=L/240, TL=L/180
• DURATION OF LOAD: 1.15%
8" x 8'-0" POURED CONCRETE WALL
6" x 4'-0" POURED CONCRETE WALL
6" x 4'-0" POURED CONCRETE WALL (MIN. 4'-0" TALL)
FIRST FLOOR WALL HEIGHT: 2 x 6 x 9' 1 1/8"
(UNLESS NOTED/SHOWN OTHERWISE)
WALL HEIGHT: 2 x 4 x 10'-3 1/4""
(UNLESS NOTED/SHOWN OTHERWISE)
FIRST FLOOR WALL HEIGHT: 2 x 4 x 9' 1 1/8"
(UNLESS NOTED/SHOWN OTHERWISE)
4" CONCRETE SLAB
11 7/8" I-JOIST @ 16" O.C.
FIRST FLOOR @ 6'-11 3/8" ABOVE SUBFLOOR
(UNLESS NOTED/SHOWN OTHERWISE)
16" O.C. (UNLESS NOTED/SHOWN OTHERWISE)
ENGINEERED WOOD TRUSSES @24" O.C.
NEW HOME PLAN SPECIFICATIONS
DEFLECTION: LL=L/480, TL=L/360
20 MIN RATED
DOOR + FRAME
5/8" TYPE 'X' DRYWALL ON
COMMON WALLS & CEILING
KITCHEN
BEDROOM #2
BEDROOM #3
DINNETTE
ENTRY
LIVING ROOM
M.
BATH
MASTER
BEDROOM
BATH
W.I.C
3/12 CEILING PITCH
CATHERDRAL CEILING
54'-0 1/2"
10'-0 1/2" 15'-6" 17'-6 1/2"
11'-11 1/2"42'-1"
15'-1"5'-11 1/2"19'-2"
22'-0 1/2"
23'-4"30'-8 1/2"
21'-5 1/2"
3'-0"
3'-0"
11'-1"
14'-2"
11'-0 1/2"
11'-1"
5'-3"
5'-0"
8'-11 1/2" 3'-8"
11'-0"
3'-3"5'-4"
9'-1 1/2" 5'-4"
4'-6" 3'-6" 3'-11 1/2"
6'-3 1/2"
23'-0 1/2"
5'-11 1/2"
19'-3" 2'-6"
2'-8"
2'-8"
2'-1"
7'-3 1/2"
11'-9 1/2"
2'-8"
3'-6"
5'-0"
4'-2"
3'-10 1/2"
4'-3"
6'-0 1/2"
3'-0"
16'-2 1/2"
11'-9"
9'-4"
DH3054
5'-1" 4'-11 1/2" 6'-6" 9'-0" 2'-6" 6'-11" 8'-1 1/2"
DH3054 DH3054
DH3054-2
DH3054-2
(LAYOUT IS CONCEPTUAL)
CATHEDRAL CEILING
CATHEDRAL CEILING
9' FLAT CEILING
2'-1 1/2" 23'-7 1/2" 16'-4"
54'-0 1/2"
11'-0 1/2" 11'-0" 2'-11 3/4" 2'-11 3/4" 7'-6 1/2" 7'-6 1/2"
16'-0"x8'-0" OVH. DR.
3'-0"
43'-1"
D.V. GAS F
IREPL
AC
E
NOTE:
FRAMING AT FIREPLACE TO MEET
FIREPLACE MANUFACTURER SPECS.
CONTRACTOR TO ADJUST
12" BOX TRAY CEILING
27'-8"3'-0 1/2"
9' FLAT CEILING
9' FLAT CEILING
9' FLAT CLG.
9' FLAT CLG.
CATHEDRAL
FLAT
OPEN RAILING
2'-8"
2'-8"
1'-9"
18'-10 1/2"4'-2"
2X4 GARAGE WALLS
@ 10'-3 1/4"3'-3 1/2" 7'-6"
10'-1 1/8" CLG
9'-1 1/8" CLG
36" x 60"
SHOWER
32"x60" T/S
6'-1 1/2"
RANGE
REF.
DW
SINK
DROP
ZONE
(2) 11 7/8" LVL HDR (EXTENDED)
6'-2"
1'-0 1/2"
FRAMED WALLS ADJUSTED OUT .5" TO
ACCOMMODATE FOR 1" FOAM
(ADJ. AS NEEDED PER HEAT LOSS CALC.)
43'-1"
DH2436
9' FLAT CEILING
10'-4"
COVERED
STOOP
15'-9 1/2" 3'-4 1/2"
9' FLAT CEILING
FLAT CLG
CANT. TRUSSES
GARAGE AREA
4" CONCRETE SLAB PITCHED
TO O.H. GARAGE DOOR
LINEN
6'-0 1/2"
4'-6" 3'-10 1/2"
3'-0"
6'-10"
4'-1"
2'-8"
4'-4 1/2"
3'-10 1/2"
2'-6"
W.I.P
8'-4"
8'-3"
LNDRY/
MUD
2X6 WALL
15'-4 1/2"
DH3054-2
3'-8"12'-7 1/2"
2'-6"
2'-6"
3'-0"
2'-8"
3'-10" 6'-10 1/2"
2'-8"
3'-4"
2'-8"
8'-0" 3'-0"
2'-8"
2'-8"
9" RUN
14 RISERS
3'-0"3'-0 1/2"
FLAT
CATHEDRAL
5'-5 1/2"
COVERED
PATIO
W.I.C
BENCH
10'-4 1/2"
3'-0"
FLUSH ENTRY
FULL LITE FLAT CEILING
DH3054-3
SIDING
HOUSE WRAP
7/16" OSB
2X6 @ 16" O/C
FULL INSULATION
4 MIL. VAPOR BARRIER
1/2" DRYWALL
RIDGE VENT
ASPHALT SHINGLES
ROOF FELT
1/2" OSB W/ H-CLIPS
ROOF TRUSSES @ 24" ROOF
TRUSSES O/C
R-50 INSULATION
6 MIL. POLY
5/8" DRYWALL
3/4" T&G OSB
11 7/8" I JOIST @ 16" O/C
4" CONCRETE SLAB
6 MIL VAPOR BARRIER
1" FOAM (ADJ AS NEEDED
PER HEAT LOSS CALC)
DAMPPROOFING
10" CONCRETE POURED
WALL
ALUM. FASCIA/SOFFIT
2X6 SUBFASCIA
HEEL HEIGHT-SEE ROOF PLAN
FORM-A-DRAIN W/
BLEEDERS AS REQUIRED
GRAVEL FILL
CONCRETE FOOTING-SIZED BY
FOUNDATION CONTRACTOR
SILL SEAL
2X6 TREATED SILL PLATE
GRADE VARIES
SPRAY FOAM INSULATION
SILL SEAL
2X4 TREATED SILL PLATE
NOTE:
ROOF VENTING + HURRICANE
CLIPS/TRUSS SCREWS PER
CODE
9'-1 1/8" 7'-8"
9'-0"
DESIGNER:
DrexelTeam.com
BID PLAN -FOR BIDDING PURPOSES ONLY
1
2
3
4
5
6
7
8
9
SCALE:
SHEET NO:
PROJECT NO:
COPYRIGHT DREXEL BUILDING SUPPLY IT IS
UNLAWFUL FOR ANYONE TO USE OR
REPRODUCE BY ANY MEANS ALL OR ANY
PORTION OF THESE DOCUMENTS WITHOUT THE
EXPRESSED WRITTEN PERMISSION OF DREXEL
BUILDING SUPPLY INC. DREXEL BUILDING
SUPPLY INC. RESERVES THE RIGHT TO USE ALL
OR PARTS OF THESE PLANS IN THE FUTURE.
ALTHOUGH EVERY EFFORT WILL BE MADE BY
DREXEL IN DESIGNING AND PREPARING THESE
PLANS AND CHECKING THEM FOR ACCURACY,
THE OWNER/GENERAL CONTRACTOR ASSUMES
ALL RESPONSIBILITY TO CHECK ALL DETAILS AND
DIMENSIONS, AND IS RESPONSIBLE FOR ANY
CHANGES OR ADJUSTMENTS REQUIRED DURING
CONSTRUCTION. DREXEL MAKES NO
REPRESENTATION FOR OR IMPLIES ACCURACY.
1/4" = 1'-0"SPRING SPEC
ADDRESS TBD BIRR INVESTMENTS
M. THOR
R23-136-W
A2
COPYRIGHT © 2023
GARAGE FLOOR AREA 502 SF
COVERED PATIO 94 SF
COVERED STOOP 38 SF
FIRST FLOOR AREA 1431 SF
TOTAL AREA 1431 SF
BID PLAN02/23/2023 MCT
REVISION03/02/2023 LJU
REVISED BID PLAN09/22/2025 LML
REVISED BID PLAN #2 10/07/2025 LML
1/4" = 1'-0"
FIRST FLOOR PLAN
WALL HEIGHT: 9'-1 1/8"
1/4" = 1'-0"
TYPICAL WALL SECTION- FLUSH ENTRY
UP
FOUNDATION INFORMATION
• HOUSE FOUNDATION
• GARAGE FOUNDATION
• PORCH/PATIO FOUNDATION (UNEXCAVATED)
• WALL THICKNESS FOR REPRESENTATION ONLY -
MASON/CONTRACTOR TO VERIFY
• FINAL WALL/POST FOOTING SIZE AND DEPTH
DETERMINED BY CONTRACTOR
• MASON TO LOCATE PILASTERS AND SIZE FOOTINGS PER
CODE AND SOIL CONDITIONS
• WINDOWS/DOORS TO BE SET IN CONCRETE WALL - MAKE
R.O. 3 ” BIGGER IN WIDTH AND HEIGHT
• BEARING WALLS TO SIT ON MIN. 16 ” X 8 ”CONT.
CONCRETE FOOTINGS, STUDS @ 16 ” O.C.
WALL INFORMATION
• HOUSE EXTERIOR
• HOUSE INTERIOR
• GARAGE
FLOOR SYSTEMS
• BASEMENT
• FIRST FLOOR
• STANDARD LOADING (PER SQ. FT.)
40 # LL. 15 # DL.
• ADDITIONAL LOADING (PER SQ. FT.) (WHEN APPLICABLE)
•
• DURATION OF LOAD: 1.00%
ROOF SYSTEMS
• .
HEADERS
• STANDARD HEADER
ALL HEADERS NOT LABELED AS LVL TO BE MIN.
(2) 2X10 HEADER FOR ON -SITE (UNLESS VALUE
ENGINEERED FOR OFF -SITE CONSTRUCTION)
• TOP OF WINDOW R.O.S.
• MINIMUM OF (2) SHOULDER STUDS AT EACH END
FOR ALL OPENINGS 6 ’-0” AND LARGER
GENERAL INFORMATION
• ALL DIMENSIONS ARE TO THE ROUGH STUD (UNLESS
NOTED OTHERWISE)
2X6 WALLS=5 ½ ”, 2X4 WALLS =3 ½ ”
• ALL DIMENSIONS ARE TO OUTSIDE OF FOUNDATION
WALLS/BRICK LEDGES
• GENERAL CONTRACTOR TO LOCATE THE FOLLOWING
ITEMS IN THE FOUNDATION (WHEN APPLICABLE)
FLOOR DRAINS, ELECTRIC SERVICES, WATER HEATER,
SUMP PIT + PUMP, FURNACE, GAS/LP LINE, BASEMENT,
WINDOWS,ETC.
• ACTUAL STEPS IN FOUNDATION WALLS AND LOCATION OF
WINDOW WELLS TO BE DETERMINED ON -SITE BY GENERAL
CONTRACTOR
• DECK FRAMING SPECIFICATION TO MEET OR EXCEED
REQUIREMENTS DEFINED WITHIN "APPENDIX B" OF THE WI
UNIFORM DWELLING
• ALL CABINET LAYOUTS ARE CONCEPTUAL -CONSULT
CABINET DESIGNER FOR EXACT SIZES AND LOCATIONS OF
CABINETS, APPLIANCES, AND WINDOWS
• ALL DOOR HEIGHTS ARE 6' -8" UNLESS NOTED/SHOWN
OTHERWISE
• STUDS @
10 # DL. FOR TILE FLOOR
13 # DL. FOR GYPCRETE.(1.5" THICK)
20 # DL. FOR FIREPLACE FACE/HEARTH
25 # DL. FOR GRANITE/QUARTZ
DESIGNED FOR: ZONE 2
• STD. LOADING (PER SQ. FT.)
30# TCLL, 10# TCDL, 10# BCDL
• DEFLECTION: LL=L/240, TL=L/180
• DURATION OF LOAD: 1.15%
8" x 8' -0" POURED CONCRETE WALL
6" x 4' -0" POURED CONCRETE WALL
6" x 4' -0" POURED CONCRETE WALL (MIN. 4' -0" TALL)
FIRST FLOOR WALL HEIGHT: 2 x 6 x 9' 1 1/8"
(UNLESS NOTED/SHOWN OTHERWISE)
WALL HEIGHT: 2 x 4 x 10' -3 1/4""
(UNLESS NOTED/SHOWN OTHERWISE)
FIRST FLOOR WALL HEIGHT: 2 x 4 x 9' 1 1/8"
(UNLESS NOTED/SHOWN OTHERWISE)
4" CONCRETE SLAB
11 7/8" I -JOIST @ 16" O.C.
FIRST FLOOR @ 6' -11 3/8" ABOVE SUBFLOOR
(UNLESS NOTED/SHOWN OTHERWISE)
16" O.C. (UNLESS NOTED/SHOWN OTHERWISE)
ENGINEERED WOOD TRUSSES @24" O.C.
NEW HOME PLAN SPECIFICATIONS
DEFLECTION: LL=L/480, TL=L/360
BEAM PKT.
LOCATION OF FIREPLACE FROM ABOVE-
SUPPORT TO BE DETERMINED BY
CONTRACTOR
VERIFY KITCHEN LOADS FROM ABOVE-
SUPPORT TO BE DETERMINED BY
CONTRACTOR.
BASEMENT
4" CONCRETE SLAB
8"CONCRETE WALLS 8' -0" (U.N.O)
W/ CONCRETE FOOTINGS (SIZED BY CONTRACTOR)
11 7/8" I JOISTS @ 16" O/C
10'-0" 15'-6" 17'-6"
19'-6" 2'-6"
G4848
EGRESS WINDOW WELL
LOCATION TO BE
VERIFIED ON SITE
22'-0" 6'-0" 15'-0"
43'-0"
12'-0" 42'-0"
54'-0"
2'-10 1/2" 16'-3" 2'-10 1/2"
9" RUN
14 RISERS
10" 16'-8" 17'-6" 7'-0"
BEAM PKT.
BEAM PKT. BEAM PKT.
8'-7" 8'-7" 8'-7" 8'-7" 8'-8"
7'-6" 7'-6"
11 7/8" I JOISTS @ 16" O/C
UNEXC.
4" CONCRETE SLAB
6" CONCRETE FROST WALLS @ 4' -0"
(U.N.O)
W/ CONCRETE FOOTINGS (SIZED BY
CONTRACTOR)
6'-2"
30'-8" 23'-4"
54'-0"
2x4 BEARING WALL W/ FOOTINGS
2'-8"
4'-6 1/2" 3'-11 1/2"
9'-5" 8'-6" 4'-1" 21'-0"
8" 4'-2" 19'-2"
(2) 9 1/4" DROPPED LVL BEAM
1'-9" 3'-3" 7'-0" 1'-0"
2'-6"
43'-0"
10" 10'-8" 4'-0 1/2"
2X4 INTERIOR
WALL ON FLAT
DOWN 8"
DOWN 8"
30"x30"x12" CONCRETE
FOOTING W.STEEL
COLUMN - TYP. UNLESS
NOTED OTHERWISE
UNEXCAVATED
4" CONCRETE SLAB PITCHED TO O.H. GARAGE DOOR
6" CONCRETE FROST WALL @ 4' -0" MIN. (U.N.O.)
CONCRETE FOOTINGS (SIZED BY FOUNDATION CONTRACTOR)
(2) 9 1/4" DROPPED LVL BEAM
T/ PORCH FOUNDATION
WALLS TBD BY CONTRACTOR
FLUSH 11 7/8" LVL HDR
6'-0"
10" 16'-8" 13'-2"
11 7/8" I JOISTS @ 16" O/C
10" THICK/ 9' -0" TALL
FOUNDATION WALLS W/ 4"
INTERIOR JOIST LEDGE
10" THICK/ 9' -0" TALL
FOUNDATION WALLS W/ 4"
INTERIOR JOIST LEDGE
10" THICK/ 9' -0" TALL
FOUNDATION WALLS W/ 4"
INTERIOR JOIST LEDGE
10" THICK/ 9' -0" TALL
FOUNDATION WALLS
10" THICK/ 9' -0" TALL
FOUNDATION WALLS
FLUSH ENTRY
PITCH SLAB TO
UNDERSIDE OF
DOOR SILL
UNEXC.
4" CONCRETE SLAB
6" CONCRETE FROST WALLS @ 4' -0"
(U.N.O)
W/ CONCRETE FOOTINGS (SIZED BY
CONTRACTOR)
3'-6" 4'-6" 4'-0" 4'-6" 3'-6"
4'-6"
2x4 BEARING WALL W/ FOOTING
33'-6" 8'-6"
8/12 PITCH
ADJ HEEL HEIGHT
1'-6"
1'-0"
1'-0"
1'-6"
1'-6"
1'-0"
1'-6"
1'-6" 6'-0"
1'-0"
6/12 PITCH
7" HEELS
6/12 PITCH
7" HEELS
1'-6" 4'-6"
8/12 PITCH
ADJ HEEL HEIGHT
8/12 PITCH
ADJ HEEL HEIGHT
1'-0"
6/12 PITCH
7" HEELS
SIDING
7/16" OSB
TYVEK
2X6 @ 16" O/C
FULL INSULATION
4 MIL. VAPOR BARRIER
1/2" DRYWALL
RIDGE VENT
ASPHALT SHINGLES
ROOF FELT
1/2" OSB W/ H-CLIPS
ROOF TRUSSES @ @ 24" O/C
R-50 INSULATION
6 MIL. POLY
5/8" DRYWALL
3/4" T&G OSB
11 7/8" I JOIST @ 16" O/C
4" CONCRETE SLAB
6 MIL VAPOR BARRIER
1" FOAM (ADJ AS NEEDED
PER HEAT LOSS CALC)
DAMPPROOFING
8" CONCRETE POURED WALL
ALUM. FASCIA/SOFFIT
2X6 SUBFASCIA
NOTE:
ROOF VENTING +
HURRICANE
CLIPS/TRUSS SCREWS
PER CODE
HEEL HEIGHT-SEE ROOF PLAN
FORM-A-DRAIN W/
BLEEDERS AS REQUIRED
GRAVEL FILL
CONCRETE FOOTING
SILL SEAL
2X6 TREATED SILL PLATE
GRADE VARIES
SPRAY FOAM INSULATION
12
6
7'-8" 9'-1 1/8"
1'-6"
DESIGNER:
DrexelTeam.com
BID PLAN -FOR BIDDING PURPOSES ONLY
1
2
3
4
5
6
7
8
9
SCALE:
SHEET NO:
PROJECT NO:
COPYRIGHT DREXEL BUILDING SUPPLY IT IS
UNLAWFUL FOR ANYONE TO USE OR
REPRODUCE BY ANY MEANS ALL OR ANY
PORTION OF THESE DOCUMENTS WITHOUT THE
EXPRESSED WRITTEN PERMISSION OF DREXEL
BUILDING SUPPLY INC. DREXEL BUILDING
SUPPLY INC. RESERVES THE RIGHT TO USE ALL
OR PARTS OF THESE PLANS IN THE FUTURE.
ALTHOUGH EVERY EFFORT WILL BE MADE BY
DREXEL IN DESIGNING AND PREPARING THESE
PLANS AND CHECKING THEM FOR ACCURACY,
THE OWNER/GENERAL CONTRACTOR ASSUMES
ALL RESPONSIBILITY TO CHECK ALL DETAILS AND
DIMENSIONS, AND IS RESPONSIBLE FOR ANY
CHANGES OR ADJUSTMENTS REQUIRED DURING
CONSTRUCTION. DREXEL MAKES NO
REPRESENTATION FOR OR IMPLIES ACCURACY.
As indicated SPRING SPEC
ADDRESS TBD BIRR INVESTMENTS
M. THOR
R23-136-W
A3
COPYRIGHT © 2023 BID PLAN 02/23/2023 MCT
REVISION 03/02/2023 LJU
REVISED BID PLAN 09/22/2025 LML
REVISED BID PLAN #2 10/07/2025 LML
GARAGE FLOOR AREA 502 SF
COVERED PATIO 94 SF
COVERED STOOP 38 SF
FIRST FLOOR AREA 1431 SF
TOTAL AREA 1431 SF
1/4" = 1'-0"
FOUNDATION PLAN
WALL HEIGHT: 8'-0"
1/8" = 1'-0"
ROOF PLAN
1/4" = 1'-0"
TYPICAL WALL SECTION
Revised 02.02.26
Below is the check list for the paperwork needed in order to obtain a building permit for any new
or remodeled stick-built dwelling.
These forms ** are included in the packet.
____ Act 211 Signature Form **
____ Completed Application **
Sign 1st and 3rd page
The highlighted form shows
information needed **
____ Cross Section ** if this info is
not on your plans
____ Building Plans
See Plan Info **
____ Plumbing Affidavit **
(For plumber)
____ Heat Calcs.
From HVAC contractor
____ Site Plan ** with Erosion. Control info documented.
Must show accurate property lines; all structures, decks, sheds, ingress & egress, etc., clearly
noted. All items must comply with City of Oconto zoning regulations.
____ Recent survey of lot (copy)
If available
___ Contact Building Inspector for Fire number/Address (new builds)
____ Contact Oconto Falls Municipal Utilities for Water and Electric Connections
____Contact City Hall for Garbage and Recycling bins if need
Revised 02.02.26
_______List of all subcontractors: Names, Addresses, Phone and Email, and required State
Certification Numbers.
☐ Builder/General Contractor ☐ Excavator ☐ Mason ☐ HVAC Contractor
☐ Electrical Company ☐ Master Electricians ☐ Plumbing ☐ Demolition Contractor
Once the above required information is received, the application will be reviewed. Amount due
will be
provided to applicant, and permit will be issued
when payment is received.
If an early start permit is required for the foundation/slab, contact me for a separate application
and it
will be reviewed and processed accordingly.
A copy of INSPECTIONS REQUIRED
sheet is included for your information. Building Inspector does not need anyone on site, but easy
access is a requirement. A copy of my report will be secured on site. It is your responsibility to
call for the correct inspections.
Please have your licensed electrician call Building Inspector for the new service inspection once
he/she has set the meter base, ground rods and panel. Building Inspector will inspect and notify
Electric company with approval.
A state licensed electrician MUST install the SERVICE per the NEC and the State.
Contacts for City of Oconto Falls
Jane Meissner, Building Inspector City Administrator Peter Wills/ City Hall
License #945930 500 N. Chestnut/ PO Box 70
715-245-1708 Oconto Falls WI. 54154
Nebuildinginspector@gmail.com Email. Pwills@cityofocontofalls.wi.gov
Phone 920-846-4505 ext 109
Fax 920-846-4516
Oconto Falls Municipal Utilities
Water and Electric Connections
500 N. Chestnut/ PO Box 70
Oconto Falls WI. 54154
Phone, 920-846-4507
Fax 920-846-4516
Date: _______________________________________________________
Project Name and Address: _______________________________________________________
This letter authorizes Jane E. Meissner, Nature's Edge Inspection Agency, Building Inspector for
The City of Oconto Falls to complete and submit to the State of Wisconsin, Department of Safety
and Professional Services, a building permit in accordance with Act 211.
Thank you.
Signature: _____________________________________________________________
Print Name: ___________________________________________________________
Date: ________________________________________________________________
INSPECTIONS
REQUIRED
FOR
NEW
DWELLINGS
AND
ADDITIONS
FOOTINGS/FOUNDATION
1. Whereforms, dampproofing, exteriorinsulationordraintilearerequiredforcodecompliance, thefooting/foundationshall beinspectedpriortobackfilling
ROUGHS
1. Aroughinspectionshall beperformedforthebasementfloorareaandtheunderfloorvaporretarderandplumbingif applicable. Roughinspectionof thegeneral constructionincluding: Framing, Roughelectrical, Roughplumbing,Roughheating, ventilatingandairconditioning.
INSULATION
1. Aninspectionshall bemadeof theinsulation andvaporretardersaftertheyareinstalledbut beforeconcealing.
FINAL/OCCUPANCY
1. Adwelling maynot beoccupieduntil afinal/occupancyinspectionhasbeenmadethat findsnocritical violationsof thecodethat couldreasonablybeexpectedtoaffect thehealthorsafetyof apersonusingthedwelling.
EROSION
CONTROL
Erosioncontrol inspections(if applicable) shall beperformedconcurrentlywithallotherrequiredconstructioninspections.
1
(5)REQUIREDPLANS. Therequiredbuildingplansshall belegibleanddrawntoscaleor dimensionedandshall includeall of thefollowing:(a) Siteplan. Thesiteplanshall showall of thefollowing:1. Thelocationof thedwellingandanyother buildings, wells,surfacewatersanddispersal systemsonthesitewithrespect topropertylinesandsurfacewatersadjacent tothesite.2. Theareasof land−disturbingconstructionactivityandthelocationof all erosionandsediment control measurestobeemployedinorder tocomplywiths. SPS321.125. Pleasedocument trackingareaondrive.3. Thepre−constructiongroundsurfaceslopeanddirectionof runoffflowwithintheproposedareasof landdisturbance.(b) Floorplan. 1. Floor plansshall beprovidedfor eachfloor.2. Thefollowingfeaturesshall beincludedonall floor plans:a. Thesizeandlocationof all rooms, doors, windows, structuralfeatures, exit passagewaysandstairs.b. Theuseof eachroom.c. Thelocationof plumbingfixtures, chimneys, heatingandcoolingappliances, andaheatingdistributionlayout. Alsothelocationof thefloor drainandelectrical panel.d. Thelocationandconstructiondetailsof wall bracingoneachbuildingsideandfloor level. Thedetailsmayconsist of theWall BracingComplianceWorksheet or alegendshowingwhichwall bracingmethodisusedandthelengthsor number of bracedwall panelsanddemarcationof thecircumscribedrectanglesifmorethanoneisused.(c) Elevations. Theelevationsshall showall of thefollowing:
1. Theexterior appearanceof thebuilding, includingthetypeof exterior materials.2. Thelocation, sizeandconfigurationof doors, windows,roof, chimneys, exterior grade, footingsandfoundationwalls.(6)REQUIREDDATA. (a) All planssubmittedfor approvalshallbeaccompaniedbysufficient data, calculationsandinformationtodetermineif thedwellingwill meet therequirementsof thiscode.(b) Thedataandinformationfor determiningcompliancewiththeenergyconservationstandardsshall besubmittedinaformatapprovedbythedepartment.(c) Except asrequiredunder s. SPS321.33, amunicipalityexercisingjurisdictionmaynot requireplansor calculationstobestampedor sealedbyanarchitect or engineer.(d) Thenameof theinitial downstreamreceivingwater of thestatefromthedwellingshall beidentified, regardingerosionandsediment control.determinesthat theplanssubmittedfor aone−or 2−familydwellingsubstantiallyconformtotheprovisionsof thiscodeandotherlegal requirements, anapproval shall beissued.
Plansmust beCONSTRUCTIONready, haveFOOTING/FOUNDATIONinformation, CUSTOMERSNAMEandbeONSITEat all times.
EXAMPLE SITE PLAN
City of Oconto Falls
500 N. Chestnut, Oconto Falls, WI. 54154
920-846-4505 – F: 920-846-4516
PROPERTY ADDRESS: _____________________________________________ RH #:____________________
OWNER NAME & ADDRESS: __________________________________________________________________
OWNER CONTACT #: ________________________ APPLICANT CONTACT #: _____________________
Provide 1 copy
of Site Plan
Show on Plan
Lot lines
Lot Dimensions
Street(s) Name
All existing Structures
Driveway location
Special Easements (provide
deed information)
Power Supply
Location of New Structure
Structure Distance to Lot Lines
Distance to Other Buildings
Property Address
Owner Name & Address
Note: If Site Plan is not complete, the
review process will be delayed.
Shed
Deck
Garage
Existing House
SITE PLAN
Property Owner contract Phone Number_______________________
Property Owner Email_____________________________
Contractors Phone Number________________Contractors Email_________________________
Dept of Safety & Professional Services
Industry Services Division
Wisconsin Uniform Building
Permit Application
Application No.
Wisconsin Stats. 101.63, 101.73
Instructions on back of second ply. The information you provide may be
used by other government agency programs [(Privacy Law, s. 15.04 (1)(m)]
Parcel No.
PERMIT REQUESTED Constr. HVAC Electric Plumbing Erosion Control Other:
Owner’s Name
Mailing Address
Email:
Tel.
Contractor Name & Type Lic/Cert# Exp Date Mailing Address Tel. & Email
Dwelling Contractor (Constr.)
Dwelling Contr. Qualifier
The Dwelling Contr. Qualifier shall be an owner,
CEO, COB or employee of the Dwelling Contr.
HVAC
Electrical Contractor
Electrical Master Electrician
Plumbing
PROJECT
LOCATION
Lot area
Sq.ft.
One acre or more of
soil will be disturbed
Town Village
City of
1/4, 1/4, of Section , T N, R E/W
Building Address
County
Subdivision Name
Lot No.
Block No.
Zoning District(s)
Zoning Permit No.
Setbacks: Front
ft.
Rear
ft.
Left
ft.
Right
ft.
1. PROJECT New Alteration Addition Repair Raze Move Other
2. AREA INVOLVED (sq ft) Unit 1 Unit 2 Total
Unfin. Bsmt.
Living Area
Garage
Deck/Porch
Totals
3. OCCUPANCY Single Family Two Family Garage Other 4. USE Seasonal Permanent Other:
5. CONSTRUCTION TYPE Site Built Mfd. Per WI UDC Mfd. Per US HUD
6. STORIES 1-Story 2-Story Other: Plus Basement 7. EST. BUILDING COST w/o LAND $
8. WALLS Wood Frame Steel ICF Timber/Pole Other 9. ELECTRIC Panel Amps: Underground Overhead
10. SEWER Municipal Sanitary Permit # 11. WATER Municipal On-Site Well
I understand that I: am subject to all applicable codes, laws, statutes and ordinances, including those described on the reverse side of the last ply of this form; am subject to
any conditions of this permit; understand that the issuance of this permit creates no legal liability, express or implied, on the state or municipality; and certify that all the
above information is accurate. If one acre or more of soil will be disturbed, I understand that this project is subject to ch. NR 151 regarding additional erosion control and
stormwater management and the owner shall sign the statement on the back of the permit if not signing below. I expressly grant the building inspector, or the inspector's
authorized agent, permission to enter the premises for which this permit is sought at all reasonable hours and for any proper purpose to inspect the work which is being done.
I vouch that I am or will be an owner-occupant of this dwelling for which I am applying for an erosion control or construction permit without a
Dwelling Contractor Certification and have read the cautionary statement regarding contractor responsibility on the reverse side of the last ply of this
form.
APPLICANT (Print:) ____________________________________ Sign:___________________________________________ DATE
APPROVAL CONDITIONS This permit is issued pursuant to the following conditions. Failure to comply may result in suspension
or revocation of this permit or other penalty. See attached for conditions of approval.
ISSUING
JURISDICTION
Town of County of
Village of State
City of
State-Contracted
Inspection Agency#:
Municipality Number of Dwelling Location
-
FEES: PERMIT(S) ISSUED WIS PERMIT SEAL # PERMIT ISSUED BY:
Plan Review
Inspection
Wis. Permit Seal
Other
Total
$
$
$
$
$
Construction
HVAC
Electrical
Plumbing
Erosion Control
__________________
Name ___________________________________________
Date _______________ Tel. ________________________
Cert No. _________________________________________
Email: ___________________________________________
SBD-5823(R1/17) Distribute: Ply 1 – Issuing Jurisdiction; Ply 2- Issuer forwards to state w/in 30 days; Ply 3- Inspector; Ply 4- Applicant
INSTRUCTIONS
The owner, builder or agents shall complete the application form down through the Signature of Applicant block and submit it and
building plans and specifications to the enforcing jurisdiction, which is usually your municipality or county. Permit application
data is used for statewide statistical gathering on new one- and two-family dwellings, as well as for local code administration.
Please type or use ink and press firmly with multi-ply form.
PERMIT REQUESTED
Check off type of Permit Requested, such as structural, HVAC, Electrical or Plumbing.
Fill in owner's current Mailing Address and Telephone Number.
If the project will disturb one acre or more of soil, the project is subject to the additional erosion control and stormwater
provisions of ch. NR 151 of the WI Administrative Code. Checking this box will satisfy the related notification requirements
of ch. NR 216.
Fill in Contractor and Contractor Qualifier Information. Per s. 101.654 (1) WI Stats., an individual taking out an erosion
control or construction permit shall enter his or her dwelling contractor certificate number, and name and certificate number
of the dwelling contractor qualifier employed by the contactor, unless they reside or will reside in the dwelling. Per s. 101.63
(7) Wis. Stats., the master plumber name and license number must be entered before issuing a plumbing permit.
PROJECT LOCATION
Fill in Building Address (number and street or sufficient information so that the building inspector can locate the site.
Local zoning, land use and flood plain requirements must be satisfied before a building permit can be issued. County
approval may be necessary.
Fill in Zoning District, lot area and required building setbacks.
1. PROJECT DATA - Fill in all numbered project data blocks (1-11) with the required information. All data blocks must be filled
in, including the following:
2. AREA (involved in project):
Basements - include unfinished area only
Living area - include any finished area including finished areas in basements
Two-family dwellings - include separate and total combined areas
3. OCCUPANCY - Check only "Single-Family" or "Two-Family" if that is what is being worked on. In other words, do not
check either of these two blocks if only a new detached garage is being built, even if it serves a one or two family dwelling .
Instead, check "Garage" and number of stalls. If the project is a community based residenti al facility serving 3 to 8 residents,
it is considered a single-family dwelling.
4. USE - Seasonal, permanent or other.
7. ESTIMATED BLDG COST - Include the total cost of construction, including materials and market rate labor, but not the cost
of land or landscaping.
10. SEWER - A building permit cannot be issued until a sanitary permit has been issued for any new or affected existing private
onsite wastewater treatment system.
SIGNATURE – The owner or the contractor’s authorized agent shall sign and date this application form. If you do not possess the
Dwelling Contractor certification, then you will need to check the owner-occupancy statement for any erosion control or
construction permits.
CONDITIONS OF APPROVAL - The authority having jurisdiction uses this section to state any conditions that must be complied
with pursuant to issuing the building permit.
ISSUING JURISDICTION: This must be completed by the authority having jurisdiction.
Check off Jurisdiction Status, such as town, village, city, county or state and fill in Municipality Name
Fill in State Inspection Agency number only if working under state inspection jurisdiction.
Fill in Municipality Number of Dwelling Location
Check off type of Permit Issued, such as construction, HVAC, electrical or plumbing.
Fill in Wisconsin Uniform Permit Seal Number, if project is a new one- or two-family dwelling.
Fill in Name and Inspector Certification Number of person reviewing building plans and date building permit issued.
Cautionary Statement to Owners Obtaining Building Permits
101.65(lr) of the Wisconsin Statutes requires municipalities that enforce the Uniform Dwelling Code to
provide an owner who applies for a building permit with a statement advising the owner that:
If the owner hires a contractor to perform work under the building permit and the contractor is not bonded
or insured as required under s. 101.654 (2) (a), the following consequences might occur:
(a) The owner may be held liable for any bodily injury to or death of others or for any damage to
the property of others that arises out of the work performed under the building permit or that is caused by
any negligence by the contractor that occurs in connection with the work performed under the building
permit.
(b) The owner may not be able to collect from the contractor damages for any loss sustained by
the owner because of a violation by the contractor of the one- and two- family dwelling code or an
ordinance enacted under sub. (1) (a), because of any bodily injury to or death of others or damage to the
property of others that arises out of the work performed under the building permit or because of any
bodily injury to or death of others or damage to the property of others that is caused by any negligence by
the contractor that occurs in connection with the work performed under the building permit.
Cautionary Statement to Contractors for Projects Involving Building Built Before 1978
If this project is in a dwelling or child-occupied facility, built before 1978, and disturbs 6 sq. ft. or more
of paint per room, 20 sq. ft. or more of exterior paint, or involves windows, then the requirements of ch.
DHS 163 requiring Lead-Safe Renovation Training and Certification apply. Call (608)261-6876 or go to
the Wisconsin Department of Health Services’ lead homepage for details of how to be in compliance
Wetlands Notice to Permit Applicants
You are responsible for complying with state and federal laws concerning the construction near or on
wetlands, lakes, and streams. Wetlands that are not associated with open water can be difficult to
identify. Failure to comply may result in removal or modification of construction that violates the law or
other penalties or costs. For more information, visit the Department of Natural Resources wetlands
identification web page or contact a Department of Natural Resources service center.
Additional Responsibilities for Owners of Projects Disturbing One or More Acre of Soil
I understand that this project is subject to ch. NR 151 regarding additional erosion control and stormwater
management and will comply with those standards.
Owner's Signature: _______________________________________ Date:___________________
Contractor Credential Requirements
All contractors shall possess an appropriate contractor credential issued by the Wisconsin Division of
Industry Services.
SBD-10605(R1/20)
Wisconsin Department of Safety and Professional Services
Division of Industry Services
4822 Madison Yards Way
PO Box 7302
Madison WI 53707-7302
Affidavit of Plumbing Testing
With the inspector’s permission, per SPS 382.21(1)(b)1b, complete entire form. Use of this form is not
mandatory. This is a suggested format that a plumber may replace with their own affidavit. Print or type
clearly. Call for your rough inspection and inform the inspector that you have completed the testing and the
affidavit. Provide this completed form to the inspector prior to or at the time of the rough-in inspection.
Date of test: Responsible Master:
Responsible MP Number:
Personal information you provide may be used for secondary purposes [Privacy Law, s. 15.04 (1)(m)].
Owner and Site Information
Owner’s Name:
Project Site Address:
Project Site City:
Type of project (check one):
New plumbing installation Remodel or addition Repair Other
If other, explain:
Testing Information
Sanitary Building Sewer or Private
Interceptor Main Sewer
Water test (10’ for 15 minutes)
Air test (3 psig for 15 minutes)
(air test not recommended for plastic pipe)
Water Service or Private Water Main
Water test (Working pressure)
Air test (Working pressure)
Building Drain
Water test (10’ except for top 10’ for 15 minutes)
Air test (5 psig for 15 minutes)
Drain & Vent System
Water test (10’ for 15 minutes)
Air test (5 psig for 15 minutes)
Water Distribution
Water test (Working pressure)
Air test (Working pressure)
Air Admittance Valves Manometer test to 1” water column
Responsible Master Plumber - signature Witness (not required) - signature
Phone: 608-266-2112
Web: http://dsps.wi.gov
Email: dsps@wisconsin.gov
Vapor Retarder Drain Tile SystemFooting
Concrete Floor
Vertical ReinforcementFoundation Wall
1/2" Anchor Bolts
Treated Sill PlateClear span, to support
Insulation
Floor Joist
Horizontal Reinforcement
Footing Reinforcement
Roof:Pitch-__________/12Shingles-_________________________________Felt-______________lb.Ice Barrier-_____________________Roof Sheathing-________________________Truss-______Yes______No (if yesif no answer the followingRafter Size-__________x_________Rafter Spacing-__________"-O.C.Rafter Clear Span-________________________________Rafter Species & Grade-_____________/______________Ridge Type & Size-_________________/______________Ceiling Joist Size-_________________________________Ceiling Joist Spacing-______________________________Ceiling Joist Species & Grade-_____________/________Insulation Type & R- Value-________________/R______Roof Ventilation-______________________________
Building Cross SectionRafterorTruss
Ceiling joist
ShinglesFeltIce BarrierRoof Sheathing
Headers
SidingSheathing
Insulation
Wall Framing
Interior FinishVapor Retarder
Foundation:Anchor Type___________________________Anchor Spacing________________________Sill Plate-_____________________________Insulation Type / R-Value-__________R-____ Wall Height-___________________________Poured Wall Size-_______________________Block Wall Size-________________________Vertical Reinforcement- #_____-_______o.c.Horizontal Reinforcement- #_____-_____o.c.Concrete Floor Thickness-______________Vapor Retarder-________________________Drain Tile Size-________________________Column Pad Size-______x______x_______Column Spacing-______________________Footing Width-_________________________Footing Heigth-________________________Footing Depth Below Grade-___________Footing Reinforcement- #_____-______o.c.
Floor:Sub-Floor___________________________Floor Joist Type______________________Floor Joist Size_______________________Floor Joist Spacing-____________________Floor Joist Clear Span-_________________Floor Joist Species-____________________Floor Joist Grade-_____________________Beam Support, Type & Size-________/____Distance From Grade-__________________
Walls:Siding-___________________________Sheathing Type & Thickness-____________/_____"Insulation Type / R-Value-______________R-____ Header Size-__________x___________Ceiling Height-________________________Stud Size & Spacing-______x_______/_____"O.C.Interior Finish-___________________________Grade of Framing Lumber -_________________Name_______________________________ Job Address______________________________________________________________________________________________________________________________________Contact Phone #____________________________________
Revised 3-1-07 jaw
truss clips must be installed if span is over 6')
Gravel Fill
Standard Erosion Control Plan
for 1- & 2-Family Dwelling Construction Sites
According to Chapters SPS 320 & 321 of the Wisconsin Uniform Dwelling Code, soil erosion control
information needs to be included on the plot plan which is submitted and approved prior to the issuance of
building permits for 1- & 2-family dwelling units in those jurisdictions where the soil erosion control
provisions of the Uniform Dwelling Code are enforced. This Standard Erosion Control Plan is provided to
assist in meeting this requirement.
Instructions:
1. Complete this plan by filling in requested information, completing the site diagram and marking
appropriate boxes on the inside of this form.
2. In completing the site diagram, give consideration to potential erosion that may occur before, during, and
after grading. Water runoff patterns can change significantly as a site is reshaped.
3. Submit this plan at the time of building permit application.
PROJECT LOCATION __________________________________________________________
BUILDER ______________________________ OWNER ______________________________
WORKSHEET COMPLETED BY _____________________ DATE _______________________
1
PROPERTY
LINE
EXISTING
DRAINAGE
TEMPORARY
DIVERSIONTD
FINISHED
DRAINAGE
LIMITS OF
GRADING
SILT
FENCE
STRAW
BALES
GRAVEL
VEGETATION
SPECIFICATION
TREE
PRESERVATION
STOCKPILED
SOIL
EROSION
CONTROL PLAN
LEGEND
Please indicate north
by completing the arrow.
NSITE DIAGRAM Scale: 1 inch = ____feet
EROSION CONTROL PLAN CHECKLIST
Check (✔) appropriate boxes below, and complete the site diagram
with necessary information.
Site Characteristics
❒ North arrow, scale, and site boundary. Indicate and name adjacent streets or roadways.
❒❒ Location of existing drainageways, streams, rivers, lakes, wetlands or wells.
❒ Location of storm sewer inlets.
❒ Location of existing and proposed buildings and paved areas.
❒ The disturbed area on the lot.
❒ Approximate gradient and direction of slopes before grading operations.
❒ Approximate gradient and direction of slopes after grading operations.
❒❒ Overland runoff (sheet flow) coming onto the site from adjacent areas.
Erosion Control Practices
❒❒ Location of temporary soil storage piles.
Note: Soil storage piles should be placed behind a sediment fence, a 10 foot wide
vegetative strip, or should be covered with a tarp or more than 25 feet from
any downslope road or drainageway.
❒ Location of access drive(s).
Note: Access drive should have 2 to 3 inch aggregate stone laid at least 7 feet wide
and 6 inches thick. Drives should extend from the roadway 50 feet or to the
house foundation (whichever is less).
❒❒ Location of sediment controls (filter fabric fence, straw bale fence or 10-foot-wide
vegetative strip) that will prevent eroded soil from leaving the site.
❒❒ Location of sediment barriers around on-site storm sewer inlets.
❒❒ Location of diversions.
Note: Although not specifically required by code, it is recommended that concen-
trated flow (drainageways) be diverted (re-directed) around disturbed areas.
Overland runoff (sheet flow)from adjacent areas greater than 10,000 sq. ft.
should also be diverted around disturbed areas.
❒❒ Location of practices that will be applied to control erosion on steep slopes (greater than
12% grade).
Note: Such practices include maintaining existing vegetation, placement of additional
sediment fences, diversions, and re-vegetation by sodding or seeding with use
of erosion control mats.
❒❒ Location of practices that will control erosion on areas of concentrated runoff flow.
Note: Unstabilized drainageways, ditches, diversions, and inlets should be protected
from erosion through use of such practices as in-channel fabric or straw bale
barriers, erosion control mats, staked sod, and rock rip-rap. When used, a
given in-channel barrier should not receive drainage from more than two acres
of unpaved area, or one acre of paved area. In-channel practices should not be
installed in perennial streams (streams with year round flow).
❒❒ Location of other planned practices not already noted.
COMPLETED
NOT APPLICABLE
COMPLETED
NOT APPLICABLE
Indicate management strategy by checking (✔) the appropriate box.
Management Strategies
❒❒ Temporary stabilization of disturbed areas.
Note: It is recommended that disturbed areas and soil piles left inactive for extended
periods of time be stabilized by seeding (between April 1 and September 15), or
by other cover, such as tarping or mulching.
❒ Permanent stabilization of site by re-vegetation or other means as soon as possible
(lawn establishment).
• Indicate re-vegetation method: ❒Seed ❒Sod ❒Other ___________
• Expected date of permanent re-vegetation: _________________________
• Re-vegetation responsibility of: ❒Builder ❒Owner/Buyer
• Is temporary seeding or mulching planned if site is not seeded by
Sept. 15 or sodded by Nov. 15? ❒Yes ❒No
❒❒ Use of downspout and/or sump pump outlet extensions.
Note: It is rec ommended that flow from downspouts and sump pump outlets be routed
through plastic drainage pipe to stable areas such as established sod or pavement.
❒❒ Trapping sediment during de-watering operations.
Note: Sediment-laden discharge water from pumping operations should be ponded
behind a sediment barrier until most of the sediment settles out.
❒ Proper disposal of building material waste so that pollutants and debris are not carried
off-site by wind or water.
❒ Maintenance of erosion control practices.
• Sediment will be removed from behind sediment fences and barriers
before it reaches a depth that is equal to half the height o f the barrier.
• Breaks and gaps in sediment fences and barriers will be repaired imme-
diately. Decomposing straw bales will be replaced (typical bale life is
three months).
• All sediment that moves off-site due to construction activity will be
cleaned up before the end of the same workday.
• All sediment that moves off-site due to storm events will be cleaned up
before the end of the next workday.
• Access drives will be maintained throughout construction.
• All installed erosion control practices will be maintained until the
disturbed areas they protect are stabilized.
Printed on
recycled paper
This publication is available from county UW-Extension offices or from Extension Publications, 45 N. Charter
St., Madison, WI 53715. (608) 262-3346 or toll-free (877) 947-7827. A publication of the University of
Wisconsin–Extension in cooperation with the Wisconsin Department of Natural Resources and the Wisconsin
Department of Commerce.GWQ001A Standard Erosion Control Plan for 1 & 2 Family Dwelling Construction Sites
DNR WT-458-96 R-03-02-2M-10-S
CONTROLS REQUIRED
• Erosion control measures specified in the Wisconsin
Construction Site Best Management Practice Handbook.
• Measures to control storm water after construction.
Check with your county, city, village, or town for any local erosion control ordinances including shoreland zoning require-
ments. Except for new 1- & 2-family dwellings, local ordinances may be more strict than state regulations. They may also
require erosion control on construction projects not affected by state or federal regulations.
EROSION CONTROL REGULATIONS
FOR MORE INFORMATION, CONTACT
• Department of Natural Resources, Storm Water Permits,
NOI Permit (Notice of Intent) P.O. 7921, Madison, WI
53707-7921,
CONTROLS REQUIRED
• Silt fences, straw bales, or other approved perimeter
measures along downslope sides and side slopes.
• Access drive.
• Straw bales, filter fabric fences or other barriers to
protect on-site sewer inlets.
• Additional controls if needed for steep slopes or other
special conditions.
FOR MORE INFORMATION, CONTACT:
• Local building inspector
• Department of Safety and & Professional Services,
P.O. Box 7970, Madison, Wis. 53707-7970
LOCAL ORDINANCES
UNIFORM DWELLING CODE (DEPT. OF SAFTEY & PROF SERVICES)
STORMWATER PERMIT (DEPT. OF NATURAL RESOURCES)
Editing and design by the Environmental Resources Center, University of Wisconsin–Extension.
Erosion control and stormwater regulations can be complex. Local, state and, in
some cases, federal regulations may apply. Before construction make sure you have
the appropriate permits.
©1999 by the Board of Regents of the University of Wisconsin System. Send inquiries about copyright permission to: Cooperative Extension
Publications, 432 North Lake Street, Madison, WI 53706. University of Wisconsin-Extension is an EEO/Affirmative Action employer and provides
equal opportunities in employment and programming, including Title IX and ADA requirements.
For more assistance on plan preparation, refer to the Wisconsin Uniform Dwelling Code, the DNR Wisconsin Construction Site
Best Management Handbook, and UW–Extension publication Erosion Control for Home Builders. The Wisconsin Uniform Dwelling
Code and the Wisconsin Construction Site Best Management Handbook are available through the State of Wisconsin Document
Sales, (608) 266-3358.
Erosion Control for Home Builders (GWQ001) can be ordered through Extension Publications, (608) 262-3346 or the Department
of Commerce, (608) 267-4405. A PDF version of Erosion Control for Home Builders (GWQ001) and Standard Erosion Control Plan
are also available at http://clean-water.uwex.edu/pubs/sheets
Source: City of Oconto Falls website. First collected Oct 20, 2026.