RecordWell Data

Spark By Hilton

9409 STATE ROAD 16, Onalaska, WI 54650 · La Crosse County

17cited violations
2serious tier
3inspections

Establishment

Type
Pool / recreational water (Swimming)
Inspected by
La Crosse County Health Department
License / ID
MWAS-D4PR7Z
Status
Permitted
Phone
(608) 881-2132
Official record
La Crosse County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
2025100
20242172

Inspections

  1. Oct 1, 2025 Routine · No items found

    No violations cited.

  2. Apr 26, 2024 Pre-inspection · No items found

    No violations cited.

  3. Apr 25, 2024 Pre-inspection · 2 critical, 15 non-critical, 6 repeat
    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 250.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. All records have been taken from premises

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Not serious Non-critical Repeat

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity. All records have been taken from premises

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      WATER LEVEL-SKIMMERS MAINTAINED

      Water level in a skimmer pool is not allowing for effective skimming. The water level is a few inches below the skimmers. Started filling during inspection

      Correction: Maintain the water level in the pool so that the skimmer weir is half submerged, or, in the case of a floating weir, used according to manufacturer's instructions.

      Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing. All records have been taken from premises

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. All records have been taken from premises

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments. All records have been taken from premises

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises: All records have been taken from premises

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises: All records have been taken from premises

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-FILTER OPERATION MANUAL

      The manual of instruction on filter operation was not permanently maintained on premises:

      Correction: Maintain the manual of instruction on filter operation on premises.

      Code ATCP 76.32(3)(a)5. - FILTER MANUAL

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-EQUIPMENT (EXCEPT FILTER) OPERATION AND MAINTENANCE

      Instructions for operation and maintenance of all equipment were not permanently maintained on premises: heater, pump, chemtrol, rolachem

      Correction: Maintain instructions for operation and maintenance of all equipment on the premises.

      Code ATCP 76.32(3)(a)6. - EQUIPMENT MANUALS

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises: All records have been taken from premises

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. All records have been taken from premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical Repeat

      POOL EQUIPMENT-REPAIRED AS NECESSARY

      The pool equipment is not repaired as necessary. Top step on pool ladder broken in half.

      Correction: The pool equipment is not repaired as necessary.

      Code ATCP 76.33(1)(e)4. - EQPT REPAIRED AS NEEDED

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. All records have been taken from premises.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical

      PH

      The pH is 8.0+.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      RESPONSIBLE SUPERVISOR RECORDS MAINTAIN

      Responsible supervisor is not ensuring that records are maintained. All records have been taken from premises.

      Correction: Have the responsible supervisor ensure that records are maintained.

      Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE

Source: La Crosse County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.