  1. Nov 3, 2025 Routine · 1 critical, 3 non-critical, 1 repeat
    • Not serious Non-critical Corrected on site

      SKIMMER POOL RECIRCULATION FLOW

      Proportion of water recirculating from skimmer and main drain is not set correctly. Main drain was mostly open and skimmers were mostly closed. Skimmer was opened during inspection and more vigorous water flow was observed

      Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.

      Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW

    • Not serious Non-critical

      SKIMMERS REPAIRED OR REPLACED AS NEEDED

      Skimmers not repaired or replaced as needed, one skimmer basket had been removed because it was broken. Skimmer basket was put back into skimmer until new ones arrive

      Correction: Repair or replace skimmer, weirs or gutters as needed.

      Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED

    • Not serious Non-critical

      EMERGENCY BLANKETS

      Two emergency blankets in good condition are not available in the pool area.

      Correction: Provide two emergency blankets in good condition in the pool area.

      Code ATCP 76.27(3) - EMERGENCY BLANKETS

    • Serious Critical Repeat

      INDOOR POOL WATER TEMPERATURE

      The indoor pool water temperature is 91.7°F. Set point on heater in pump room is 94F

      Correction: Maintain the pool water temperature between 70°F or 21°C and 90°F or 32°C.

      Code ATCP 76.19(4)(b)1 - INDOOR POOL WATER TEMP

  2. Nov 18, 2024 Re-inspection · No items found

    No violations cited.

  3. Nov 4, 2024 Re-inspection · 3 critical, 4 non-critical, 5 repeat
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition. Bobber is stuck at 100 and sand is observed in tube

      Correction: Repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      POOL BASIN ROUTINELY BRUSHED, VACUUMED

      Pool basin is not routinely brushed or vacuumed to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration. Pool oberved with excessive sediment on bottom of basin

      Correction: Routinely brush or vacuum the pool basin to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration.

      Code ATCP 76.33(1)(a)1- POOL BASIN BRUSHED, VACUUMED

    • Not serious Non-critical Repeat

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical Repeat

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity. Pool has not been tested for alkalinity since 10/9

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Serious Critical Repeat

      RESPONSIBLE SUPERVISOR FOR POOL

      The pool does not have a responsible supervisor.

      Correction: Provide a responsible supervisor for the pool.

      Code ATCP 76.21 (1)(a) - RESPONSIBLE SUPERVISOR REQUIRED

    • Serious Critical Repeat

      CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS

      The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. At time of inspection pool sanitizer was 0ppm for bromine and pH was less than 7.0, operator was unaware of this due to lack of testing and proper training.

      Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.

      Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14

    • Serious Critical Repeat

      CLOSING CRITERIA-NO RESPONSIBLE SUPERVISOR

      The operator has not closed the pool due to the absence or non−availability of a responsible supervisor.

      Correction: Close the pool in the event of absence or non−availability of a responsible supervisor.

      Code ATCP 76.30 (1)(f) - NO RESPONSIBLE SUPERVISOR

  4. Oct 17, 2024 Routine · 8 critical, 6 non-critical
    • Not serious Non-critical

      ALKALINITY

      The total alkalinity is 40.

      Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.

      Code ATCP 76.14(5)(d) - ALKALINITY

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 210 mV and water has not been tested manually. System had red light flashing upon entry to pump room

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      TEST KIT APPROVED

      Test strips are not approved for use in commercial pools, must use approved test kit.

      Code ATCP 76.17 (1) - DEPARTMENT-APPROVED

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity. Pool has not been tested for alkalinity since 10/9

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical Corrected on site

      WATER LEVEL-SKIMMERS MAINTAINED

      Floating weir observed not sitting properly in skimmer. Weir was put back into skimmer correctly.

      Correction: Maintain the water level in the pool so that the skimmer weir is half submerged, or, in the case of a floating weir, used according to manufacturer's instructions.

      Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED

    • Not serious Non-critical

      FIRST AID KIT-EYE WASH SOLUTION

      [REPEAT] The eyewash solution in the first aid kit expired 5/21.

      Correction: Provide eye wash solution for the first aid kit.

      Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION

    • Serious Critical

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0ppm for bromine

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH is less than 7.0. Chemtrol system indicates it is at 7.1.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER

      Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Pool testing logs indicates pool has not been tested since 10/9.

      Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.

      Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE

    • Serious Critical

      INDOOR POOL WATER TEMPERATURE

      The indoor pool water temperature is 93°F.

      Correction: Maintain the pool water temperature between 70°F or 21°C and 90°F or 32°C.

      Code ATCP 76.19(4)(b)1 - INDOOR POOL WATER TEMP

    • Serious Critical

      RESPONSIBLE SUPERVISOR FOR POOL

      The pool does not have a responsible supervisor.

      Correction: Provide a responsible supervisor for the pool.

      Code ATCP 76.21 (1)(a) - RESPONSIBLE SUPERVISOR REQUIRED

    • Serious Critical

      CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS

      The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. At time of inspection pool sanitizer was 0ppm for bromine and pH was less than 7.0, operator was unaware of this due to lack of testing and proper training.

      Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.

      Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14

    • Serious Critical

      CLOSING CRITERIA-NO RESPONSIBLE SUPERVISOR

      The operator has not closed the pool due to the absence or non−availability of a responsible supervisor.

      Correction: Close the pool in the event of absence or non−availability of a responsible supervisor.

      Code ATCP 76.30 (1)(f) - NO RESPONSIBLE SUPERVISOR

    • Serious Critical

      GATES AND DOORS-LATCHING

      One of the main doors into pool enclosure does not latch/lock when it swings shut.

      Correction: Provide a latching door.

      Code ATCP 76.34(4)(a)(1m)(b)- LATCHING

  5. Sep 6, 2023 Routine · 1 non-critical
    • Not serious Non-critical Corrected on site

      SKIMMER/MAIN DRAIN RATIO INCORRECT

      The skimmer to main drain flow ratio is not set correctly, main drain was at 100% and skimmer was at about 75%. Main drain closed to about 20%

      Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.

      Code [A] ATCP 76.11(2)(a)