Springbrook Assisted Living
861 CRITTER CT, Onalaska, WI 54650 · La Crosse County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- La Crosse County Health Department
- License / ID
- HSAT-7QXLCA
- Status
- Permitted
- Phone
- (608) 783-2292
- Official record
- La Crosse County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 1 | 4 | 1 |
| 2024 | 3 | 21 | 11 |
| 2023 | 1 | 1 | 0 |
Inspections
-
Nov 3, 2025 Routine · 1 critical, 3 non-critical, 1 repeat
-
Not serious
Non-critical
Corrected on site
SKIMMER POOL RECIRCULATION FLOW
Proportion of water recirculating from skimmer and main drain is not set correctly. Main drain was mostly open and skimmers were mostly closed. Skimmer was opened during inspection and more vigorous water flow was observed
Correction: Adjust equipment so that proportion of water recirculating from skimmer and main drain is mostly from skimmer.
Code ATCP 76.11(2)(a) 2. b. - SKIMMER POOL RECIRCULATION FLOW
-
Not serious
Non-critical
SKIMMERS REPAIRED OR REPLACED AS NEEDED
Skimmers not repaired or replaced as needed, one skimmer basket had been removed because it was broken. Skimmer basket was put back into skimmer until new ones arrive
Correction: Repair or replace skimmer, weirs or gutters as needed.
Code ATCP 76.11(2)(b) 2. - SKIMMERS REPAIRED OR REPLACED
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area.
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Serious
Critical
Repeat
INDOOR POOL WATER TEMPERATURE
The indoor pool water temperature is 91.7°F. Set point on heater in pump room is 94F
Correction: Maintain the pool water temperature between 70°F or 21°C and 90°F or 32°C.
Code ATCP 76.19(4)(b)1 - INDOOR POOL WATER TEMP
-
Not serious
Non-critical
Corrected on site
-
Nov 18, 2024 Re-inspection · No items found
No violations cited.
-
Nov 4, 2024 Re-inspection · 3 critical, 4 non-critical, 5 repeat
-
Not serious
Non-critical
FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED
The flowmeter is not being maintained in operating condition. Bobber is stuck at 100 and sand is observed in tube
Correction: Repair the flowmeter.
Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED
-
Not serious
Non-critical
POOL BASIN ROUTINELY BRUSHED, VACUUMED
Pool basin is not routinely brushed or vacuumed to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration. Pool oberved with excessive sediment on bottom of basin
Correction: Routinely brush or vacuum the pool basin to keep the basin and surrounding appurtenances free of sediment, lint, hair, debris, algae, and slime growth and discoloration.
Code ATCP 76.33(1)(a)1- POOL BASIN BRUSHED, VACUUMED
-
Not serious
Non-critical
Repeat
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
Repeat
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Pool has not been tested for alkalinity since 10/9
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Serious
Critical
Repeat
RESPONSIBLE SUPERVISOR FOR POOL
The pool does not have a responsible supervisor.
Correction: Provide a responsible supervisor for the pool.
Code ATCP 76.21 (1)(a) - RESPONSIBLE SUPERVISOR REQUIRED
-
Serious
Critical
Repeat
CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS
The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. At time of inspection pool sanitizer was 0ppm for bromine and pH was less than 7.0, operator was unaware of this due to lack of testing and proper training.
Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.
Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14
-
Serious
Critical
Repeat
CLOSING CRITERIA-NO RESPONSIBLE SUPERVISOR
The operator has not closed the pool due to the absence or non−availability of a responsible supervisor.
Correction: Close the pool in the event of absence or non−availability of a responsible supervisor.
Code ATCP 76.30 (1)(f) - NO RESPONSIBLE SUPERVISOR
-
Not serious
Non-critical
-
Oct 17, 2024 Routine · 8 critical, 6 non-critical
-
Not serious
Non-critical
ALKALINITY
The total alkalinity is 40.
Correction: Maintain the total alkalinity of the water between 60 and 180 ppm as calcium carbonate or be able to demonstrate to the department or its agent that another level of total alkalinity produces chemically balanced water.
Code ATCP 76.14(5)(d) - ALKALINITY
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 210 mV and water has not been tested manually. System had red light flashing upon entry to pump room
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
TEST KIT APPROVED
Test strips are not approved for use in commercial pools, must use approved test kit.
Code ATCP 76.17 (1) - DEPARTMENT-APPROVED
-
Not serious
Non-critical
ALKALINITY TEST
Pool water not tested at least once a week for total alkalinity. Pool has not been tested for alkalinity since 10/9
Correction: Test pool water at least once a week for total alkalinity.
Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY
-
Not serious
Non-critical
Corrected on site
WATER LEVEL-SKIMMERS MAINTAINED
Floating weir observed not sitting properly in skimmer. Weir was put back into skimmer correctly.
Correction: Maintain the water level in the pool so that the skimmer weir is half submerged, or, in the case of a floating weir, used according to manufacturer's instructions.
Code ATCP 76.19(3)(a) - SKIMMERS MAINTAINED
-
Not serious
Non-critical
FIRST AID KIT-EYE WASH SOLUTION
[REPEAT] The eyewash solution in the first aid kit expired 5/21.
Correction: Provide eye wash solution for the first aid kit.
Code ATCP 76.27(1)(b)5. - EYE WASH SOLUTION
-
Serious
Critical
MINIMUM DISINFECTANT RESIDUAL
Minimum disinfectant or sanitizer level is 0ppm for bromine
Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.
Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL
-
Serious
Critical
PH
The pH is less than 7.0. Chemtrol system indicates it is at 7.1.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
POOL WATER TESTED BEFORE OPENING, PH AND SANITIZER
Pool water is not tested for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use. Pool testing logs indicates pool has not been tested since 10/9.
Correction: Test pool water for pH and disinfectant or sanitizer residual daily before the pool is open to the public or before the pool is in use.
Code ATCP 76.18(1)(a)1 - POOL TESTED SANITIZER AND PH, BEFORE OPE
-
Serious
Critical
INDOOR POOL WATER TEMPERATURE
The indoor pool water temperature is 93°F.
Correction: Maintain the pool water temperature between 70°F or 21°C and 90°F or 32°C.
Code ATCP 76.19(4)(b)1 - INDOOR POOL WATER TEMP
-
Serious
Critical
RESPONSIBLE SUPERVISOR FOR POOL
The pool does not have a responsible supervisor.
Correction: Provide a responsible supervisor for the pool.
Code ATCP 76.21 (1)(a) - RESPONSIBLE SUPERVISOR REQUIRED
-
Serious
Critical
CLOSING CRITERIA-FAILURE TO COMPLY WITH 76.14 OR PH LIMITS
The Responsible Supervisor or operator has not closed the pool after failure to comply with the disinfectant or sanitizer residual levels. At time of inspection pool sanitizer was 0ppm for bromine and pH was less than 7.0, operator was unaware of this due to lack of testing and proper training.
Correction: Close the pool in the event of failure to comply with the disinfectant or sanitizer residual levels pursuant to s. ATCP 76.14, or pH values that are less than 6.8 or equal to or greater than 8.0.
Code ATCP 76.30 (1)(c) - FAILURE TO COMPLY WITH ATCP 76.14
-
Serious
Critical
CLOSING CRITERIA-NO RESPONSIBLE SUPERVISOR
The operator has not closed the pool due to the absence or non−availability of a responsible supervisor.
Correction: Close the pool in the event of absence or non−availability of a responsible supervisor.
Code ATCP 76.30 (1)(f) - NO RESPONSIBLE SUPERVISOR
-
Serious
Critical
GATES AND DOORS-LATCHING
One of the main doors into pool enclosure does not latch/lock when it swings shut.
Correction: Provide a latching door.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Not serious
Non-critical
-
Sep 6, 2023 Routine · 1 non-critical
-
Not serious
Non-critical
Corrected on site
SKIMMER/MAIN DRAIN RATIO INCORRECT
The skimmer to main drain flow ratio is not set correctly, main drain was at 100% and skimmer was at about 75%. Main drain closed to about 20%
Correction: Readjust the flow so that only 20% comes through the main drain and 80% comes through the skimmers.
Code [A] ATCP 76.11(2)(a)
-
Not serious
Non-critical
Corrected on site
Source: La Crosse County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.