Stoney Creek Inn
3060 KINNEY COULEE RD S, Onalaska, WI 54650 · La Crosse County
Establishment
- Type
- Pool / recreational water (Whirlpool)
- Inspected by
- La Crosse County Health Department
- License / ID
- HSAT-7QWGXB
- Status
- Permitted
- Phone
- (608) 781-3060
- Official record
- La Crosse County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2026 | 1 | 5 | 1 |
| 2025 | 1 | 8 | 2 |
| 2024 | 1 | 4 | 0 |
Inspections
-
Apr 13, 2026 Routine · 1 critical, 4 non-critical, 1 repeat
-
Not serious
Non-critical
ACTION PLAN - OBJECTIVES MET
The operator did not meet the objectives outlined in the combined chlorine action plan. Combined chlorine was at 0.8 PPM in whirl pool, action level is 0.6 PPM.
Correction: Complete the requirements of action plan.
Code ATCP 76.07(4)(c) - ACTION PLAN OBJECTIVES MET
-
Not serious
Non-critical
FLOWMETER, VALVE OR GAUGE NOT INSTALLED PER MANUFACTURER OR AS VERIFIED BY PUMP CURVE
The whirlpool flowmeter is not installed according to manufacturer instructions with the floater on the incorrect side. Flowmeter may need to be replaced with one that has a range of GPM lower than what is currently available also.
Correction: Install the flowmeter according to manufacturer instructions or as verified by pump curve.
Code ATCP 76.11(5)(b) - FLOWMETER, VALVE, GAUGE NOT INSTALLED PRO
-
Not serious
Non-critical
WHIRLPOOL, THERAPY POOL, EXERCISE POOL,COMBINED CHLORINE
Chlorine is used in a whirl pool and pool water is not tested at least once daily for the combined chlorine level.
Correction: Test whirl pool water at least once daily for the combined chlorine level.
Code ATCP 76.18(2)(b) - COMBINED CHLORINE, WHIRLPOOL, EX, THERAPY
-
Not serious
Non-critical
Repeat
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The multi-lift mechanical chair is not in good repair, does not function properly. Unsure if battery issue or wiring issue. Chair also has visible rust in various places.
Correction: Maintain the pool equipment in clean and working condition.
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
HOSING - BACKFLOW PREVENTION DEVICE
Backflow prevention devices were missing from all 3 hose bibs used to hose down the pool and whirl pool decks. 2 were replaced during inspection.
Correction: Provide all hose bibs with backflow prevention
Code ATCP 76.33(1)(d)2. - BACKFLOW PREVENTION
-
Not serious
Non-critical
-
Feb 13, 2025 Routine · 2 critical, 6 non-critical
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is not being recorded daily on chemical testing logs. Maintaining within correct limits at time of inspection
Correction: Maintain and record water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
TELEPHONE-EMERGENCY NUMBERS AND ADDRESS
The facility address is not posted near emergency telephone.
Correction: Provide a list of emergency numbers and facility address, attached or posted near telephone or other telecommunication technology device.
Code ATCP 76.26(2)(d) - TELEPHONE, EMERGENCY NUMBERS POSTED
-
Not serious
Non-critical
Corrected on site
POOL RULES LETTER OR SYMBOL SIZE
Whirl pool rules posted are not at least one inch in height. Rules posted were from the old rule requirements from years ago as the current rule sign with one inch lettering was in disrepair (fallen off wall, corners torn). Current rule sign with one inch lettering places back out by whirl pool
Correction: Correct the size of the letters or symbols, so that letters are at least one inch in height and symbols are at least 4 inches in height.
Code ATCP 76.29(1)(a)2. -LETTER OR SYMBOL SIZE
-
Not serious
Non-critical
Corrected on site
WHIRLPOOLS-RULES, MINORS UNDER AGE 6
Signage for whirlpool is missing this rule: Minors under the age of 6 are not permitted in the whirlpool. Rules posted were from the old rule requirements from years ago as the current rule sign with this rule provided was in disrepair (fallen off wall, corners torn). Current rule sign with the correct/current rules is now back out by whirl pool
Correction: Include rule stating: Minors under the age of 6 are not permitted in the whirlpool.
Code ATCP 76.29(3)(e) - NO CHILDREN UNDER 6
-
Not serious
Non-critical
POOL BASIN MAINTAINED FREE OF DEFECTS
Whirl pool basin not maintained free of cracks or other defects and repaired or refinished as necessary to maintain it in a cleanable condition. - Has a few spots on the walls of the whirl pool where the finish is coming off leaving 'holes' or 'pits' - Has some cracks along the bottom of the basin
Correction: Maintained the pool basin free of cracks or other defects, and repaired or refinished as necessary to maintain it in a cleanable condition.
Code ATCP 76.33(1)(a)2 - POOL BASIN GOOD REPAIR
-
Not serious
Non-critical
POOL EQUIPMENT-PROPERLY MAINTAINED
The pool equipment is not properly maintained. The ADA chair does not currently have a functional battery available for it's use
Correction: Maintain the pool equipment. Maintain functional batteries and charge as needed
Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT
-
Serious
Critical
WATER SUPPLY PROTECTION
Approved backflow or backsiphonage protection does not exist between potable water supply inlet and the overflow point of pool - hose connected when using to fill basin
Correction: Provide approved backflow and backsiphonage protection between the water supply and the overflow point of any pool, makeup tank, surge tank, solution tank, or slurry tank.
Code ATCP 76.19(1) - PROTECTION
-
Serious
Critical
Corrected on site
TELEPHONE-OTHER TECHNOLOGIES,RELIABLE SERVICE CONNECTION
The emergency telephone does not have reliable service connection, does not provide dial tone at time of inspection. Corrected by replacing with new phone during inspection
Correction: Provide a reliable service connection for the communication technology.
Code ATCP 76.26(2)(b)2. - TELEPHONE, OTHER TECHNOLOGIES, CONNECTI
-
Not serious
Non-critical
-
Mar 7, 2024 Routine · 4 non-critical
-
Not serious
Non-critical
REAGENTS STORAGE CONTAINER
Bottle of R-0009 has crack in dropper part of bottle causing inaccurate drop size. Reagent R-0871 is not stored in original container
Correction: Replace bottles to be in original containers and in good repair
Code ATCP 76.17 (2)(a) - REAGENT STORAGE BOTTLES
-
Not serious
Non-critical
EMERGENCY BLANKETS
Two emergency blankets in good condition are not available in the pool area. Only one available
Correction: Provide two emergency blankets in good condition in the pool area.
Code ATCP 76.27(3) - EMERGENCY BLANKETS
-
Not serious
Non-critical
FILES RETAINED 2 YEARS-DAILY INSPECTIONS AND OPERATIONAL TESTS
Daily inspection and operational tests records not maintained on premises for 2 years. Missing records from March 23 - November 23
Correction: Maintain on premises for 2 years reports of daily inspections and operational tests.
Code ATCP 76.32(3)(b)4. - DAILY INSPECTION AND OPERATIONAL TESTS
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Recovery strips in various areas are missing, broken, or sinking into deck.
Correction: Maintain pool deck area in good repair.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Not serious
Non-critical
Source: La Crosse County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.