  1. Oct 1, 2025 Routine · 2 non-critical
    • Not serious Non-critical

      FLOWMETER, VALVE, OR GAUGE NOT MAINTAINED

      The flowmeter is not being maintained in operating condition. Bobber is stuck at the bottom and it may be becuase it was installed incorrectly.

      Correction: Adjust or repair the flowmeter.

      Code ATCP 76.11(5)(a) - FLOWMETER, VALVE, GAUGE NOT MAINTAINED

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 550 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

  2. Aug 19, 2024 Pre-inspection Follow Up · No items found

    No violations cited.

  3. Jun 11, 2024 Pre-inspection Follow Up · 4 critical, 15 non-critical, 19 repeat
    • Not serious Non-critical Repeat

      CHEMICAL FEEDERS USED-AUTOMATIC

      Chemtrol feeder is not automatic or working properly. Is alarming and will not allow for manual adjustment

      Correction: Repair and calibrate Chemtrol feeder or install a new automatic chemical feeder of the same exact type.

      Code ATCP 76.13 (1)(b)1. - AUTOMATIC

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 575 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY

      Whirlpool water not tested at least once a week for total alkalinity. Records not available

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY

    • Not serious Non-critical Repeat

      ELECTRONIC MONITORING FREQUENCY OF TESTING

      The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual. No records onsite available

      Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.

      Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ

    • Not serious Non-critical Repeat

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing. All records have been taken from premises

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical Repeat

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing. No records available, have all been removed from premises

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. All records have been taken from premises

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments. All records have been taken from premises

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises: No longer available on premises

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises: has been taken from premises

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-FILTER OPERATION MANUAL

      The manual of instruction on filter operation was not permanently maintained on premises: is no longer available

      Correction: Maintain the manual of instruction on filter operation on premises.

      Code ATCP 76.32(3)(a)5. - FILTER MANUAL

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-EQUIPMENT (EXCEPT FILTER) OPERATION AND MAINTENANCE

      Instructions for operation and maintenance of all equipment were not permanently maintained on premises: All have been taken for pump, rolachem, chemtrol, heater.

      Correction: Maintain instructions for operation and maintenance of all equipment on the premises.

      Code ATCP 76.32(3)(a)6. - EQUIPMENT MANUALS

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. All records have been taken from premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical Repeat

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair. Cracks in fountation near and around whirlpool.

      Correction: Maintain pool deck area in good repair.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Not serious Non-critical Repeat

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. All documentation has been taken from premises.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical Repeat

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0 PPM bromine. Shock added during inspection went up to 17 PPM

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical Repeat

      PH

      The pH is 8.0.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical Repeat

      RESPONSIBLE SUPERVISOR SANITATION AND TESTING

      Responsible supervisor is not ensuring that sanitation and testing is performed. No records onsite, all pool documents taken from site.

      Correction: Have the responsible supervisor ensure that sanitation and testing duties are performed.

      Code ATCP 76.21 (1)(c)4. - SANITAITON AND TESTING

    • Serious Critical Repeat

      RESPONSIBLE SUPERVISOR RECORDS MAINTAIN

      Responsible supervisor is not ensuring that records are maintained. All records have been removed from site.

      Correction: Have the responsible supervisor ensure that records are maintained.

      Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE

  4. Apr 26, 2024 Pre-inspection · No items found

    No violations cited.

  5. Apr 25, 2024 Pre-inspection · 4 critical, 15 non-critical, 7 repeat
    • Not serious Non-critical

      CHEMICAL FEEDERS USED-AUTOMATIC

      Chemtrol feeder is not automatic or working properly. Is alarming and will not allow for manual adjustment

      Correction: Repair and calibrate Chemtrol feeder or install a new automatic chemical feeder of the same exact type.

      Code ATCP 76.13 (1)(b)1. - AUTOMATIC

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 575 mV and water has not been tested manually.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical Repeat

      WHIRLPOOL, THERAPY POOL, EXERCISE POOL, ALKALINITY

      Whirlpool water not tested at least once a week for total alkalinity. Records not available

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(2)(c) - ALKALINITY, WHIRL, EX, THERAPY

    • Not serious Non-critical

      ELECTRONIC MONITORING FREQUENCY OF TESTING

      The pool, with an electronic monitoring device, has not been manually tested at least once a day with an approved test kit for pH and disinfectant or sanitizer residual. No records onsite available

      Correction: Manually test the pool at least once a day for pH and disinfectant or sanitizer residual with an approved test kit.

      Code ATCP 76.18(3)(a) - ELECTRONIC MONITORING TEST FREQ

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing. All records have been taken from premises

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator did not record the following on the operating report: Results for chemical testing. No records available, have all been removed from premises

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical Repeat

      OPERATING REPORTS-BACKWASH

      The operator did not record the following on the operating report: The dates on which backwashing was completed. All records have been taken from premises

      Correction: Record the following on the operating report, the dates when backwashing was completed.

      Code ATCP 76.32(1)(b) - BACKWASH

    • Not serious Non-critical Repeat

      OPERATING REPORTS-INTERLOCK TESTING

      The operator did not record the following on the operating report: Dates of interlock tests, results and comments. All records have been taken from premises

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-ATCP 76 CURRENT COPY

      A copy of the most current version of ch. ATCP 76 was not permanently maintained on premises: No longer available on premises

      Correction: Maintain a copy of the most current version of ch. ATCP 76 on premises.

      Code ATCP 76.32(3)(a)1. - CURRENT ATCP 76 COPY

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-PUMP CURVE

      The manufacturer’s pump performance curve diagram was not permanently maintained on premises: has been taken from premises

      Correction: Maintain a copy of the manufacturer’s pump performance curve diagram on the premises.

      Code ATCP 76.32(3)(a)3. - PUMP CURVE

    • Not serious Non-critical Repeat

      FILES MAINTAINED PERMANENT-FILTER OPERATION MANUAL

      The manual of instruction on filter operation was not permanently maintained on premises: is no longer available

      Correction: Maintain the manual of instruction on filter operation on premises.

      Code ATCP 76.32(3)(a)5. - FILTER MANUAL

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-EQUIPMENT (EXCEPT FILTER) OPERATION AND MAINTENANCE

      Instructions for operation and maintenance of all equipment were not permanently maintained on premises: All have been taken for pump, rolachem, chemtrol, heater.

      Correction: Maintain instructions for operation and maintenance of all equipment on the premises.

      Code ATCP 76.32(3)(a)6. - EQUIPMENT MANUALS

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-CDC FECAL INCIDENTS

      The most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents was not permanently maintained on premises:

      Correction: Maintain a copy of the most recent United States centers for disease control and prevention recommendations for fecal accidents or another plan in response to fecal accidents that is consistent with the United States centers for disease control and prevention’s fecal accident response recommendations on the premises.

      Code ATCP 76.32(3)(a)8. - CDC FECAL RESPONSE GUIDELINES

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises. All records have been taken from premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical Repeat

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair. Cracks in fountation near and around whirlpool.

      Correction: Maintain pool deck area in good repair.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement. All documentation has been taken from premises.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical Repeat

      MINIMUM DISINFECTANT RESIDUAL

      Minimum disinfectant or sanitizer level is 0 PPM bromine. Shock added during inspection went up to 17 PPM

      Correction: Close the pool until disinfectant level is in compliance with ATCP 76.14 Table A.

      Code ATCP 76.14(5)(a) - MINIMUM DISINFECTANT RESIDUAL

    • Serious Critical

      PH

      The pH is 8.0.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      RESPONSIBLE SUPERVISOR SANITATION AND TESTING

      Responsible supervisor is not ensuring that sanitation and testing is performed. No records onsite, all pool documents taken from site.

      Correction: Have the responsible supervisor ensure that sanitation and testing duties are performed.

      Code ATCP 76.21 (1)(c)4. - SANITAITON AND TESTING

    • Serious Critical

      RESPONSIBLE SUPERVISOR RECORDS MAINTAIN

      Responsible supervisor is not ensuring that records are maintained. All records have been removed from site.

      Correction: Have the responsible supervisor ensure that records are maintained.

      Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE