La Crosse Country Club

300 MARCOU, Onalaska, WI 54650 · La Crosse County

33cited violations
7serious tier
5inspections

Establishment

Type
Pool / recreational water (Combination)
Inspected by
La Crosse County Health Department
License / ID
HSAT-7QWEY8
Status
Permitted
Phone
(608) 781-5837
Official record
La Crosse County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20262134
2025192
2024161
2023150

Inspections

  1. Aug 18, 2026 Re-inspection · 1 critical, 1 repeat
    • Serious Critical Repeat

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided. Drinking fountain has been removed. A water cooler with cups was placed on the pool deck during inspection, but was not available for a portion of the inspection.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

  2. Jul 7, 2026 Routine · 3 critical, 9 non-critical, 2 repeat
    • Not serious Non-critical Repeat Corrected on site

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. Current GPM is at 570, which does not allow the pool to turn over water every 6 hours. Flow adjusted to maintain a GPM of at least 603 during inspection.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate and ensure that the GPM maintains at or above 600 GPM at all times.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      SAFETY DATA SHEET

      A safety data sheet was not available for any of the chemicals used in the pool area.

      Correction: Maintain a safety data sheet for each chemical on site.

      Code ATCP 76.12 (4)(b)1. - SAFETY DATA SHEETS

    • Not serious Non-critical

      INTERLOCK-LOG KEPT

      A log of the monthly interlock tests is not being kept.

      Correction: Keep a log of monthly interlock tests.

      Code ATCP 76.13 (1)(c)4 - INTERLOCK, LOG KEPT

    • Not serious Non-critical Repeat

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      COMBINED CHLORINE TEST

      Chlorine is used and pool water is not tested at least twice a week for the combined chlorine level. Combined chlorine testing is not being done.

      Correction: Test pool water at least twice a week for the combined chlorine level.

      Code ATCP 76.18(1)(b) - WATER TESTED COMBINED CHLORINE,

    • Not serious Non-critical

      ALKALINITY TEST

      Pool water not tested at least once a week for total alkalinity.

      Correction: Test pool water at least once a week for total alkalinity.

      Code ATCP 76.18(1)(c) - WATER TESTED ALKALINITY

    • Not serious Non-critical

      CYANURIC TEST

      Cyanuric acid is used in the pool basin and the cyanuric acid concentration is not tested at least once a week.

      Correction: Test water for the cyanuric acid at least once a week.

      Code ATCP 76.18(1)(d) - WATER TESTED CYANURIC

    • Not serious Non-critical

      FECAL, VOMIT, BLOOD, DOCUMENT CHEMICAL CONCENTRATIONS AT TIME OF EVENT

      For a fecal, blood or vomit incident, the date, time, and chemical concentrations when the event occurred were not documented. Fecal incident occurred within the last month, and it was not documented how the fecal matter was cleaned.

      Correction: Document date, time, and chemical concentrations when the event occurred. Record the date and time of the event, and the free available chlorine or bromine.

      Code ATCP 76.31(2)(a) - CHEMICAL CONCENTRATIONS AT TIME OF EVENT

    • Not serious Non-critical

      VGBA-DRAIN COVER INFO-DOCUMENTS-DRAIN COVER LOG PRESENT

      The operator does not have a log that can be used to evaluate the drain covers, and there is no alternative form of proof available about drain cover replacement.

      Correction: Maintain a log that can be used to evaluate the drain covers, or keep receipts or affidavits that show make and model of drain cover.

      Code ATCP 76.38(2)(a) - DRAIN COVER LOG

    • Serious Critical Corrected on site

      PH

      The pH is 8.0. pH corrected to 7.8.

      Correction: Maintain the pH at 7.2 to 7.8. Recommend keeping pH between 7.4-7.6. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical

      DRINKING FOUNTAIN PROVIDED

      There is no drinking fountain provided. Drinking fountain has been removed. A water cooler with cups was placed on the pool deck during inspection, but was not available for a portion of the inspection.

      Correction: Provide a drinking fountain within 300 feet walking distance.

      Code ATCP 76.33(1)(g)1. DRINKING FOUNTAIN PROVIDED

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve or drain cover specifications. Drain cover specifications and pump curve are not kept on site for review.

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  3. Jul 18, 2025 Routine · 2 critical, 7 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. Current gallons per minute flow rate for the large pool is 475 gpm, which is not enough to maintain the 6 hour turnover.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of at least 600 gpm to achieve a turnover rate of at least 6 hours.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical

      COMBINED CHLORINE PLAN PRESENT

      The operator has not developed and implemented a plan to minimize combined chlorine in the pool. The previous plan that was implemented was not available for reivew.

      Correction: Develop and implement a plan to minimize combined chlorine in the pool.

      Code ATCP 76.14(5)(e)1. - PLAN PRESENT

    • Not serious Non-critical

      RESPONSIBLE SUPERVISOR INTERLOCK TESTING

      Records to show interlock testing were not available for review at time of inspection. Responsible supervisor indicated over the phone that these records are maintained digitally.

      Correction: Have the responsible supervisor ensure that monthly interlock tests are done and recorded.

      Code ATCP 76.21 (1)(c)5.- INTERLOCK TESTING

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-EQUIPMENT (EXCEPT FILTER) OPERATION AND MAINTENANCE

      Instructions for operation and maintenance of all equipment were not permanently maintained on premises. Responsible supervisor indicated via phone that all records are available on the computer, but could not be reviewed during inspection.

      Correction: Maintain instructions for operation and maintenance of all equipment on the premises.

      Code ATCP 76.32(3)(a)6. - EQUIPMENT MANUALS

    • Not serious Non-critical

      FILES MAINTAINED PERMANENT-VGBA DRAIN COVER DOCUMENTATION

      The Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation was not permanently maintained on premises.

      Correction: Maintain Virginia Graeme Baker Act main drain and equalizer cover replacement receipts or similar documentation on the premises.

      Code ATCP 76.32(3)(a)9. - VGBA DRAIN COVER

    • Not serious Non-critical

      SHOWER, TOILET, DRESSING FACILITIES-MAINTAINED

      The front right shower in both the boys and girls locker rooms do not have a good water flow. Water only trickles out of the faucets and is not good for showering.

      Correction: Maintain the shower, toilet and dressing facilities in good repair.

      Code ATCP 76.33 (2)(a)1. - GOOD REPAIR

    • Not serious Non-critical

      POOL EQUIPMENT-PROPERLY MAINTAINED

      The pool equipment is not properly maintained. The pool ladder to the right of the guard chair at the 4 ft end and to the left of the guard chair the 10 ft end are loose.

      Correction: Maintain the pool equipment and tighten the ladders.

      Code ATCP 76.33(1)(e)3. - MAINTENANCE OF POOL EQPT

    • Serious Critical

      CHEMICAL STORAGE ACCESS RESTRICTED

      Chemical storage area door is not kept locked during open swim hours.

      Correction: Restrict access to chemical storage area to only authorized personnel.

      Code ATCP 76.12 (2)(d) - ACCESS RESTRICTED

    • Serious Critical

      RESPONSIBLE SUPERVISOR RECORDS MAINTAIN

      Records are not available on site for review at the time of inspection. Missing pool testing records for combined chlorine, alkalinity, and cyanuric acid. Responsible supervisor indicated over the phone that these records are maintained digitally.

      Correction: Have the responsible supervisor ensure that records are maintained.

      Code ATCP 76.21 (1)(c)7. - RECORDS MAINTENANCE

  4. Jul 15, 2024 Routine · 1 critical, 5 non-critical
    • Not serious Non-critical

      SKIMMERS MAINTAINED CLEAN

      Center main drain cover is blocked with sand and leaf litter.

      Correction: Maintain the drain covers in clean condition.

      Code ATCP 76.11(2)(b) 1. - SKIMMERS CLEAN

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. The R-0870 DPD Powder has a best by date of 6/2024.

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      LIFEGUARD, ATTENDANT STAFFING PLAN-DIAGRAM, LIFEGUARD CHAIRS

      The lifeguard and attendant staffing plan is missing diagrams for maximum patron load for open swim, swim lessons, and swim meets. Currently there is only one diagram for the average patron load swim.

      Correction: Provide a diagram that shows location of lifeguard chairs for all of the activities listed above, in the lifeguard and attendant staffing plan.

      Code ATCP 76.22(1)(b)7.d - LIFEGUARD CHAIRS

    • Not serious Non-critical

      FIRST AID KIT-INSTANT COLD PACKS

      The first aid kit is missing instant cold packs.

      Correction: Provide instant cold packs for the first aid kit.

      Code ATCP 76.27(1)(b)9. - INSTANT COLD PACKS

    • Not serious Non-critical

      POSTING SIGNAGE- NO PROLONGED BREATH HOLDING

      Signage or other communication warning against prolonged breath-holding is not posted or otherwise provided.

      Correction: Provide signage or provide other communication warning against prolonged breath holding. Provide signage that is in at least 1 inch high lettering.

      Code ATCP 76.29(1)(f) - NO PROLONGED BREATH HOLDING

    • Serious Critical Corrected on site

      CO ALARM-POOL EQUIPMENT ROOM

      There is a fuel-burning device in the equipment room but no functional CO alarm in the equipment room. A functioning CO detector was provided in the equipment room during this inspection.

      Correction: Provide a CO alarm in the equipment room and install per manufacturer's instructions.

      Code ATCP 76.33(4)(d)1. -CO ALARM EQPT ROOM

  5. Jun 20, 2023 Routine · 5 non-critical
    • Not serious Non-critical Corrected on site

      CHEMICAL LABELING

      Clear sprayer in pump room is not labeled according to ATCP 76.12(1). Container labeled during inspection.

      Correction: Label the chemical container according to ATCP 76.12(1).

      Code ATCP 76.12(1)

    • Not serious Non-critical

      MSDS AVAILABILITY

      Material safety data sheets are not available for all chemicals used in the facility.

      Correction: Provide material safety data sheets for all chemicals used in the facility.

      Code ATCP 76.12(4)(b)

    • Not serious Non-critical

      REAGENTS STORED IN ORIGINAL CONTAINERS

      R-0003 in Taylor FAS-DPD test kit expired 03/2023.

      Correction: Replace expired reagents.

      Code ATCP 76.17(2)

    • Not serious Non-critical

      DRINKING FOUNTAIN NOT FUNCTIONAL

      The drinking fountain is not functional and has been removed from the pool enclosure.

      Correction: Replace the drinking fountain.

      Code [A] ATCP 76.33(1)(g)

    • Not serious Non-critical

      BLANKETS MISSING

      Only one durable blankets is available in the pool area.

      Correction: Provide 2 durable blankets in the pool area.

      Code [B] ATCP 76.27(1)

Source: La Crosse County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.