Baymont Inn & Suites
3300 N KINNEY COULEE RD, Onalaska, WI 54650 · La Crosse County
Establishment
- Type
- Pool / recreational water (Swimming)
- Inspected by
- La Crosse County Health Department
- License / ID
- ASTS-A8GHRB
- Status
- Permitted
- Phone
- (608) 783-7191
- Official record
- La Crosse County Health Department inspection reports
Year by year
| Year | Inspections | Violations | Serious |
|---|---|---|---|
| 2025 | 2 | 10 | 3 |
| 2024 | 2 | 15 | 9 |
Inspections
-
Jul 28, 2025 Re-inspection · No items found
No violations cited.
-
Jul 23, 2025 Routine · 3 critical, 7 non-critical, 4 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Turnover rate is 9.2 hours. The pool should turnover every 6 hours.
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of less than 6 hours.
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
INTERLOCKED-ELECTRICAL
Power to recirculation system is not interlocked with the power to the chemical feed. Pool has electrical interlock system, when tested during inspection the chemical feed did not stop.
Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT
-
Not serious
Non-critical
ELECTRONIC MONITORING WATER POTENTIAL
The water potential ("ORP") is 619 mV and water has not been tested twice a day for chlorine.
Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.
Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL
-
Not serious
Non-critical
REAGENTS REPLACED
Test kit reagents not replaced as recommended by the manufacturer. The following reagents were observed to be expired: - pH indicator expired 2/23 -R-0871 expired 4/24 -R-009 expired 9/24 -R-0870 expired 7/22
Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.
Code ATCP 76.17 (2)(b) - REAGENTS REPLACED
-
Not serious
Non-critical
OPERATING REPORTS-CHEMICAL TESTING
The operator does not record combined chlorine or alkalinity testing. Operator states he tests at least twice a week for combined chlorine and alkalinity.
Correction: Record the following on the operating report, results for chemical testing.
Code ATCP 76.32(1)(a) - CHEMICAL TESTING
-
Not serious
Non-critical
OPERATING REPORTS-INTERLOCK TESTING
The operator does not record the dates and results of interlock tests.
Correction: Record the following on the operating report, dates of interlock tests, results and comments.
Code ATCP 76.32(1)(d) - INTERLOCK TEST
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area is not maintained in good repair. There are two circular spots about 6 inches wide each on the pool deck where the pool deck is sunken in and the paint is cracked. One spot is located inbetween the whirlpool and pool. The other is located on the side of the pool near the windows by the 4
Correction: Maintain pool deck area in good repair. Patch the areas where the pool deck has sunken in.
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
PH
The pH is 8. Operator stated the pH is high because they recently raised alkalinity.
Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.
Code ATCP 76.14(5)(c) - PH
-
Serious
Critical
Repeat
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area. First aid kit in pool area is observed to be empty. Operator stated first aid kit is kept at front desk. Front desk is more than 25 feet away from the pool area.
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
Repeat
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The main drain and equalizer covers are expired. Replace as soon as possible and provide health department with new drain cover information when replaced.
Correction: Correct the hazardous condition. Replace the main drain and equalizer covers.
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Not serious
Non-critical
Repeat
-
Apr 24, 2024 Re-inspection · 4 critical, 3 non-critical, 7 repeat
-
Not serious
Non-critical
Repeat
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Turnover rate is currently at 7.87 hours, the rate should be less than 6 hours
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Repeat
Corrected on site
INTERLOCKED-ELECTRICAL
Pool has electrical interlock system, when tested during inspection the chemical feed did not stop. Interlock system sensor was fixed during inspection and was observed working correctly. This would have results in a re-inspection if not corrected during inspection
Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT
-
Not serious
Non-critical
Repeat
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Tiles near hot tub entrance, pool stairs and corner of pool observed cracked and missing.
Correction: Maintain pool deck area in good repair [Describe].
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
Repeat
CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS
Liquid chlorine stored next to liquid acid with no secondary containment
Correction: Store oxidizers separately from acids.
Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS
-
Serious
Critical
Repeat
Corrected on site
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, all items are currently located at front desk which is further than 25 feet. All items added to pool area first aid kit
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
Repeat
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The equilizers are expired. Replace as soon as possible and provide health department with date of installation
Correction: Install new equalizers
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Serious
Critical
Repeat
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Repeat
-
Apr 18, 2024 Routine · 5 critical, 3 non-critical
-
Not serious
Non-critical
RECIRCULATION (TURNOVER) RATE NOT MET
The recirculation (turnover) rate has not been met. Turnover rate is currently at 7.87 hours, the rate should be less than 6 hours
Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].
Code ATCP 76.11(4)(c) - RECIRCULATION RATE
-
Not serious
Non-critical
Corrected on site
INTERLOCKED-ELECTRICAL
Pool has electrical interlock system, when tested during inspection the chemical feed did not stop. Interlock system sensor was fixed during inspection and was observed working correctly. This would have results in a re-inspection if not corrected during inspection
Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).
Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT
-
Not serious
Non-critical
POOL DECK-GOOD REPAIR
Pool deck area not maintained in good repair. Tiles near hot tub entrance, pool stairs and corner of pool observed cracked and missing.
Correction: Maintain pool deck area in good repair [Describe].
Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR
-
Serious
Critical
CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS
Liquid chlorine stored next to liquid acid with no secondary containment
Correction: Store oxidizers separately from acids.
Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS
-
Serious
Critical
Corrected on site
FIRST AID KIT-PROVIDED IN POOL AREA
The first aid kit is missing from the pool area, all items are currently located at front desk which is further than 25 feet. All items added to pool area first aid kit
Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.
Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT
-
Serious
Critical
HAZARDOUS CONDITION
There is a hazardous condition at the pool. The equilizers are expired. Replace as soon as possible and provide health department with date of installation
Correction: Install new equalizers
Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA
-
Serious
Critical
GATES AND DOORS-LATCHING
The entrance door to the pool room from the bathroom does not latch, pool door can be pulled open. Install a latch mechanism at least 54 inches high. Keep the doors locked until latch is installed.
Correction: Provide a latching door.
Code ATCP 76.34(4)(a)(1m)(b)- LATCHING
-
Serious
Critical
VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO
The operator of an existing pool does not have the pump curve
Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.
Code ATCP 76.38(1)(b) - PUMP CURVE
-
Not serious
Non-critical
Source: La Crosse County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.