Baymont Inn & Suites

3300 N KINNEY COULEE RD, Onalaska, WI 54650 · La Crosse County

25cited violations
12serious tier
4inspections

Establishment

Type
Pool / recreational water (Swimming)
Inspected by
La Crosse County Health Department
License / ID
ASTS-A8GHRB
Status
Permitted
Phone
(608) 783-7191
Official record
La Crosse County Health Department inspection reports

Other public records for this business

Year by year

YearInspectionsViolationsSerious
20252103
20242159

Inspections

  1. Jul 28, 2025 Re-inspection · No items found

    No violations cited.

  2. Jul 23, 2025 Routine · 3 critical, 7 non-critical, 4 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. Turnover rate is 9.2 hours. The pool should turnover every 6 hours.

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate of less than 6 hours.

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat

      INTERLOCKED-ELECTRICAL

      Power to recirculation system is not interlocked with the power to the chemical feed. Pool has electrical interlock system, when tested during inspection the chemical feed did not stop.

      Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).

      Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT

    • Not serious Non-critical

      ELECTRONIC MONITORING WATER POTENTIAL

      The water potential ("ORP") is 619 mV and water has not been tested twice a day for chlorine.

      Correction: Maintain water potential between 650−900 mV, and manually test the water if the water potential reads below 650 mV or above 900 mV.

      Code ATCP 76.14(6)(a) - OXIDATION POTENTIAL

    • Not serious Non-critical

      REAGENTS REPLACED

      Test kit reagents not replaced as recommended by the manufacturer. The following reagents were observed to be expired: - pH indicator expired 2/23 -R-0871 expired 4/24 -R-009 expired 9/24 -R-0870 expired 7/22

      Correction: Discard expired reagents. Replace test kit reagents as recommended by the manufacturer.

      Code ATCP 76.17 (2)(b) - REAGENTS REPLACED

    • Not serious Non-critical

      OPERATING REPORTS-CHEMICAL TESTING

      The operator does not record combined chlorine or alkalinity testing. Operator states he tests at least twice a week for combined chlorine and alkalinity.

      Correction: Record the following on the operating report, results for chemical testing.

      Code ATCP 76.32(1)(a) - CHEMICAL TESTING

    • Not serious Non-critical

      OPERATING REPORTS-INTERLOCK TESTING

      The operator does not record the dates and results of interlock tests.

      Correction: Record the following on the operating report, dates of interlock tests, results and comments.

      Code ATCP 76.32(1)(d) - INTERLOCK TEST

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Pool deck area is not maintained in good repair. There are two circular spots about 6 inches wide each on the pool deck where the pool deck is sunken in and the paint is cracked. One spot is located inbetween the whirlpool and pool. The other is located on the side of the pool near the windows by the 4

      Correction: Maintain pool deck area in good repair. Patch the areas where the pool deck has sunken in.

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical

      PH

      The pH is 8. Operator stated the pH is high because they recently raised alkalinity.

      Correction: Maintain the pH at 7.2 to 7.8. Note: *it is strongly encouraged to use a pH meter with an accuracy greater than 0.1 or better.

      Code ATCP 76.14(5)(c) - PH

    • Serious Critical Repeat

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area. First aid kit in pool area is observed to be empty. Operator stated first aid kit is kept at front desk. Front desk is more than 25 feet away from the pool area.

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical Repeat

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. The main drain and equalizer covers are expired. Replace as soon as possible and provide health department with new drain cover information when replaced.

      Correction: Correct the hazardous condition. Replace the main drain and equalizer covers.

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

  3. Apr 24, 2024 Re-inspection · 4 critical, 3 non-critical, 7 repeat
    • Not serious Non-critical Repeat

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. Turnover rate is currently at 7.87 hours, the rate should be less than 6 hours

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Repeat Corrected on site

      INTERLOCKED-ELECTRICAL

      Pool has electrical interlock system, when tested during inspection the chemical feed did not stop. Interlock system sensor was fixed during inspection and was observed working correctly. This would have results in a re-inspection if not corrected during inspection

      Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).

      Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT

    • Not serious Non-critical Repeat

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair. Tiles near hot tub entrance, pool stairs and corner of pool observed cracked and missing.

      Correction: Maintain pool deck area in good repair [Describe].

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical Repeat

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      Liquid chlorine stored next to liquid acid with no secondary containment

      Correction: Store oxidizers separately from acids.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical Repeat Corrected on site

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area, all items are currently located at front desk which is further than 25 feet. All items added to pool area first aid kit

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical Repeat

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. The equilizers are expired. Replace as soon as possible and provide health department with date of installation

      Correction: Install new equalizers

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical Repeat

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

  4. Apr 18, 2024 Routine · 5 critical, 3 non-critical
    • Not serious Non-critical

      RECIRCULATION (TURNOVER) RATE NOT MET

      The recirculation (turnover) rate has not been met. Turnover rate is currently at 7.87 hours, the rate should be less than 6 hours

      Correction: Immediately adjust or repair equipment to operate at a proper turnover rate [Describe].

      Code ATCP 76.11(4)(c) - RECIRCULATION RATE

    • Not serious Non-critical Corrected on site

      INTERLOCKED-ELECTRICAL

      Pool has electrical interlock system, when tested during inspection the chemical feed did not stop. Interlock system sensor was fixed during inspection and was observed working correctly. This would have results in a re-inspection if not corrected during inspection

      Correction: Provide interlock between the power to the recirculation system and power to the chemical feeder(s).

      Code ATCP 76.13 (1)(c)1.a. - ELECTRICAL INTERLOCK PRESENT

    • Not serious Non-critical

      POOL DECK-GOOD REPAIR

      Pool deck area not maintained in good repair. Tiles near hot tub entrance, pool stairs and corner of pool observed cracked and missing.

      Correction: Maintain pool deck area in good repair [Describe].

      Code ATCP 76.33(1)(b)1.a. - DECK GOOD REPAIR

    • Serious Critical

      CHEMICAL STORAGE, SEPARATION OF OXIDIZERS AND ACIDS

      Liquid chlorine stored next to liquid acid with no secondary containment

      Correction: Store oxidizers separately from acids.

      Code ATCP 76.12 (2)(c) - CHEMICAL SEPARATION OXIDIZERS, ACIDS

    • Serious Critical Corrected on site

      FIRST AID KIT-PROVIDED IN POOL AREA

      The first aid kit is missing from the pool area, all items are currently located at front desk which is further than 25 feet. All items added to pool area first aid kit

      Correction: Provide a first aid kit in the pool area or, if the first aid kit is within 25 feet of the enclosure, post signage that tells where the first aid kit is located.

      Code ATCP 76.27(1)(a) - FIRST AID KIT PRESENT

    • Serious Critical

      HAZARDOUS CONDITION

      There is a hazardous condition at the pool. The equilizers are expired. Replace as soon as possible and provide health department with date of installation

      Correction: Install new equalizers

      Code ATCP 76.34(1) - HAZARDOUS CONDITION AT POOL AREA

    • Serious Critical

      GATES AND DOORS-LATCHING

      The entrance door to the pool room from the bathroom does not latch, pool door can be pulled open. Install a latch mechanism at least 54 inches high. Keep the doors locked until latch is installed.

      Correction: Provide a latching door.

      Code ATCP 76.34(4)(a)(1m)(b)- LATCHING

    • Serious Critical

      VGBA-EXISTING POOLS, PUMP CURVE AND DRAIN COVER INFO

      The operator of an existing pool does not have the pump curve

      Correction: Obtain a pump curve and information that describes make, model and gpm rating for the drain covers.

      Code ATCP 76.38(1)(b) - PUMP CURVE

Source: La Crosse County Health Department. History last read Oct 11, 2026. Violation text is the inspector's wording. “Serious” is the source's own top tier. About this data.